Timed and DCE/Time service (dtsd)

ITEM: RTA000071374



                                                                                
                                                                                
 We have some problem when configuring DCE on a machine running timed :         
 dtsd refuses to start correctly. After many investigations, we've              
 finished to stop timed and we've reconfigured DCE. And now DCE                 
 seems working well. But this machine has to be the master server               
 for timed in the network.                                                      
 My question is: can timed coexist with dce/dtsd ?                              
 How can we get rid of this problem if not ?                                    
                                                                                
                                                                                
                                                                                
ANSWER                                                                          
                                                                                
It seems to me that you would not want to have timed running as a              
"client" while also using dts as a clerk. I will check w/development            
on the interaction of using timed as a master while using the dts as            
a clerk....                                                                     
                                                                                
Here is our answer from development:                                            
"We have observed problems with AIX when more than one process                  
is attempting to adjust the clock.  At one time we had the                      
kernel panic when running timed and dtsd.  Since there should                   
only be one process setting the clock we put a time lock                        
mechanism into the DTSD so that it would not run if any other                   
time daemons that use the same locking mechanism were                           
running..."                                                                     
                                                                                
S e a r c h - k e y w o r d s:                                                  
TIMED DTS DTSD                                                                 


WWQA: ITEM: RTA000071374 ITEM: RTA000071374