7024-E20 and unattended start mode
ITEM: RS4000004397
Question........:
Hello.
A big customer here needs some clarification on 7024-E20 and
unattended start mode: although the option of unattended start mode
is available in SMS, it does not work at all: even with this mode
set and acknowledged in SMS, pulling out and then in the power plug
the E20 does not restart: the power led blinks, that's all. It should
restart and just lock the keyboard until the power on password is
typed, but nothing happens.
Does it need the service processor? It's not available on the E20!
Answer..........:
====> THIS TEXT HAS BEEN ENTERED BY IBM IN FRANCE
Your question is being escalated
Be patient
Answer..........:
====> THIS TEXT HAS BEEN ENTERED BY IBM IN FRANCE
Question........:
Hello.
A big customer here needs some clarification on 7024-E20 and
unattended start mode: although the option of unattended start mode
is available in SMS, it does not work at all: even with this mode
set and acknowledged in SMS, pulling out and then in the power plug
the E20 does not restart: the power led blinks, that's all. It should
restart and just lock the keyboard until the power on password is
typed, but nothing happens.
Does it need the service processor? It's not available on the E20!
**************> ANSWER level 2 --> level 1 SPECIALIST <**************
====> THIS TEXT HAS BEEN ENTERED BY IBM IN USA
PMR E0230,998,706 was created on 96/12/11 at 10:26:11.
**************> ANSWER level 2 --> level 1 SPECIALIST <**************
====> THIS TEXT HAS BEEN ENTERED BY IBM IN USA
Answer..........:
TIME:0721
Received by Austin ITSC and assigned to AIXHDW.
Your question has been received, and assigned to a specialist. Please
wait for a reply. Thank you.
**************> ANSWER level 2 --> level 1 SPECIALIST <**************
====> THIS TEXT HAS BEEN ENTERED BY IBM IN USA
Answer..........:
TIME:0856
Your item has been received.
**************> ANSWER level 2 --> level 1 SPECIALIST <**************
====> THIS TEXT HAS BEEN ENTERED BY IBM IN USA
Answer..........:
TIME:1134
RESPONSE:
Unfortunately, on the E20, the reset button must be pressed.
Human intervention is required when rebooting after a power failure on
the E20. If you would like the availability of the Unattended Start
Mode feature added to the E20, you can submit a Request for Price
Quotation (RPQ).
Thank you for using AIX Technical Support Services.
Question........:
If it's not available on the E20, the unattended start mode option
should at least be greyed out in SMS!
What about the E30/F30? Does it work with those models? Does it
need the service processor then? SMOL is not very clear on the
subject...
Thanks.
Answer..........:
Question........:
Hello.
A big customer here needs some clarification on 7024-E20 and
unattended start mode: although the option of unattended start mode
is available in SMS, it does not work at all: even with this mode
set and acknowledged in SMS, pulling out and then in the power plug
the E20 does not restart: the power led blinks, that's all. It should
restart and just lock the keyboard until the power on password is
typed, but nothing happens.
Does it need the service processor? It's not available on the E20!
**************> ANSWER level 2 --> level 1 SPECIALIST <**************
====> THIS TEXT HAS BEEN ENTERED BY IBM IN USA
PMR E0230,998,706 was created on 96/12/11 at 10:26:11.
**************> ANSWER level 2 --> level 1 SPECIALIST <**************
====> THIS TEXT HAS BEEN ENTERED BY IBM IN USA
Answer..........:
TIME:0721
Received by Austin ITSC and assigned to AIXHDW.
Your question has been received, and assigned to a specialist. Please
wait for a reply. Thank you.
**************> ANSWER level 2 --> level 1 SPECIALIST <**************
====> THIS TEXT HAS BEEN ENTERED BY IBM IN USA
Answer..........:
TIME:0856
Your item has been received.
**************> ANSWER level 2 --> level 1 SPECIALIST <**************
====> THIS TEXT HAS BEEN ENTERED BY IBM IN USA
Answer..........:
TIME:1134
RESPONSE:
Unfortunately, on the E20, the reset button must be pressed.
Human intervention is required when rebooting after a power failure on
the E20. If you would like the availability of the Unattended Start
Mode feature added to the E20, you can submit a Request for Price
Quotation (RPQ).
Thank you for using AIX Technical Support Services.
**************> QUESTION level 1 --> level 2 SPECIALIST <**************
====> THIS TEXT HAS BEEN ENTERED BY IBM IN FRANCE
Question........:
Hello.
A big customer here needs some clarification on 7024-E20 and
unattended start mode: although the option of unattended start mode
is available in SMS, it does not work at all: even with this mode
set and acknowledged in SMS, pulling out and then in the power plug
the E20 does not restart: the power led blinks, that's all. It should
restart and just lock the keyboard until the power on password is
typed, but nothing happens.
Does it need the service processor? It's not available on the E20!
Answer..........:
====> THIS TEXT HAS BEEN ENTERED BY IBM IN FRANCE
Your question is being escalated
Be patient
Answer..........:
====> THIS TEXT HAS BEEN ENTERED BY IBM IN FRANCE
Question........:
Hello.
A big customer here needs some clarification on 7024-E20 and
unattended start mode: although the option of unattended start mode
is available in SMS, it does not work at all: even with this mode
set and acknowledged in SMS, pulling out and then in the power plug
the E20 does not restart: the power led blinks, that's all. It should
restart and just lock the keyboard until the power on password is
typed, but nothing happens.
Does it need the service processor? It's not available on the E20!
**************> ANSWER level 2 --> level 1 SPECIALIST <**************
====> THIS TEXT HAS BEEN ENTERED BY IBM IN USA
PMR E0230,998,706 was created on 96/12/11 at 10:26:11.
**************> ANSWER level 2 --> level 1 SPECIALIST <**************
====> THIS TEXT HAS BEEN ENTERED BY IBM IN USA
Answer..........:
TIME:0721
Received by Austin ITSC and assigned to AIXHDW.
Your question has been received, and assigned to a specialist. Please
wait for a reply. Thank you.
**************> ANSWER level 2 --> level 1 SPECIALIST <**************
====> THIS TEXT HAS BEEN ENTERED BY IBM IN USA
Answer..........:
TIME:0856
Your item has been received.
**************> ANSWER level 2 --> level 1 SPECIALIST <**************
====> THIS TEXT HAS BEEN ENTERED BY IBM IN USA
Answer..........:
TIME:1134
RESPONSE:
Unfortunately, on the E20, the reset button must be pressed.
Human intervention is required when rebooting after a power failure on
the E20. If you would like the availability of the Unattended Start
Mode feature added to the E20, you can submit a Request for Price
Quotation (RPQ).
Thank you for using AIX Technical Support Services.
Question........:
If it's not available on the E20, the unattended start mode option
should at least be greyed out in SMS!
What about the E30/F30? Does it work with those models? Does it
need the service processor then? SMOL is not very clear on the
subject...
Thanks.
**************> ANSWER level 2 --> level 1 SPECIALIST <**************
====> THIS TEXT HAS BEEN ENTERED BY IBM IN USA
PMR E0230,998,706 was updated on 96/12/13 at 13:22:13.
**************> ANSWER level 2 --> level 1 SPECIALIST <**************
====> THIS TEXT HAS BEEN ENTERED BY IBM IN USA
Answer..........:
TIME:0859
YOUR ADDITIONAL INFORMATION HAS BEEN RECEIVED.
**************> ANSWER level 2 --> level 1 SPECIALIST <**************
====> THIS TEXT HAS BEEN ENTERED BY IBM IN USA
Answer..........:
TIME:1113
RESPONSE:
The E30 and F30 require all require human interaction when
rebooting after recovering from a power failure. There is a feature
code for a Service Processor on the E30 and F30. This is an ISA card
that is plugged into an available slot. The Service Processor has a
function which allow the system to power- on after a power failure.
ENABLE/DISABLE UNATTENDED START MODE
This option may be used to instruct SP(Service Processor) to
immediately power-on after a power failure, bypassing power-on
password verification. It is intended to be used on servers that
require automatic power-on after a power failure.
Without the Service Processor, the E30 and F30 cannot
automatically reboot after a power failure has occurred.
Thank you for using AIX Technical Support.
**************> QUESTION level 1 --> level 2 SPECIALIST <**************
====> THIS TEXT HAS BEEN ENTERED BY IBM IN FRANCE
Question........:
Hello.
A big customer here needs some clarification on 7024-E20 and
unattended start mode: although the option of unattended start mode
is available in SMS, it does not work at all: even with this mode
set and acknowledged in SMS, pulling out and then in the power plug
the E20 does not restart: the power led blinks, that's all. It should
restart and just lock the keyboard until the power on password is
typed, but nothing happens.
Does it need the service processor? It's not available on the E20!
**************> ANSWER level 2 --> level 1 SPECIALIST <**************
====> THIS TEXT HAS BEEN ENTERED BY IBM IN USA
PMR E0230,998,706 was created on 96/12/11 at 10:26:11.
**************> ANSWER level 2 --> level 1 SPECIALIST <**************
====> THIS TEXT HAS BEEN ENTERED BY IBM IN USA
====> ASGN: BUNLOEUR AT WTSCPOK ================= DATE:961211
TIME:0721
Received by Austin ITSC and assigned to AIXHDW.
Your question has been received, and assigned to a specialist. Please
wait for a reply. Thank you.
**************> ANSWER level 2 --> level 1 SPECIALIST <**************
====> THIS TEXT HAS BEEN ENTERED BY IBM IN USA
====> RESP: AIXOPSYS AT WTSCPOK ================= DATE:961211
TIME:0856
Your item has been received.
**************> ANSWER level 2 --> level 1 SPECIALIST <**************
====> THIS TEXT HAS BEEN ENTERED BY IBM IN USA
====> RESP: AIXOPSYS AT WTSCPOK ================= DATE:961211
TIME:1134
RESPONSE:
Unfortunately, on the E20, the reset button must be pressed.
Human intervention is required when rebooting after a power failure on
the E20. If you would like the availability of the Unattended Start
Mode feature added to the E20, you can submit a Request for Price
Quotation (RPQ).
Thank you for using AIX Technical Support Services.
**************> QUESTION level 1 --> level 2 SPECIALIST <**************
====> THIS TEXT HAS BEEN ENTERED BY IBM IN FRANCE
Question........:
Hello.
A big customer here needs some clarification on 7024-E20 and
unattended start mode: although the option of unattended start mode
is available in SMS, it does not work at all: even with this mode
set and acknowledged in SMS, pulling out and then in the power plug
the E20 does not restart: the power led blinks, that's all. It should
restart and just lock the keyboard until the power on password is
typed, but nothing happens.
Does it need the service processor? It's not available on the E20!
Answer..........:
====> THIS TEXT HAS BEEN ENTERED BY IBM IN FRANCE
Your question is being escalated
Be patient
Answer..........:
====> THIS TEXT HAS BEEN ENTERED BY IBM IN FRANCE
Question........:
Hello.
A big customer here needs some clarification on 7024-E20 and
unattended start mode: although the option of unattended start mode
is available in SMS, it does not work at all: even with this mode
set and acknowledged in SMS, pulling out and then in the power plug
the E20 does not restart: the power led blinks, that's all. It should
restart and just lock the keyboard until the power on password is
typed, but nothing happens.
Does it need the service processor? It's not available on the E20!
**************> ANSWER level 2 --> level 1 SPECIALIST <**************
====> THIS TEXT HAS BEEN ENTERED BY IBM IN USA
PMR E0230,998,706 was created on 96/12/11 at 10:26:11.
**************> ANSWER level 2 --> level 1 SPECIALIST <**************
====> THIS TEXT HAS BEEN ENTERED BY IBM IN USA
Answer..........:
TIME:0721
Received by Austin ITSC and assigned to AIXHDW.
Your question has been received, and assigned to a specialist. Please
wait for a reply. Thank you.
**************> ANSWER level 2 --> level 1 SPECIALIST <**************
====> THIS TEXT HAS BEEN ENTERED BY IBM IN USA
Answer..........:
TIME:0856
Your item has been received.
**************> ANSWER level 2 --> level 1 SPECIALIST <**************
====> THIS TEXT HAS BEEN ENTERED BY IBM IN USA
Answer..........:
TIME:1134
RESPONSE:
Unfortunately, on the E20, the reset button must be pressed.
Human intervention is required when rebooting after a power failure on
the E20. If you would like the availability of the Unattended Start
Mode feature added to the E20, you can submit a Request for Price
Quotation (RPQ).
Thank you for using AIX Technical Support Services.
Question........:
If it's not available on the E20, the unattended start mode option
should at least be greyed out in SMS!
What about the E30/F30? Does it work with those models? Does it
need the service processor then? SMOL is not very clear on the
subject...
Thanks.
**************> ANSWER level 2 --> level 1 SPECIALIST <**************
====> THIS TEXT HAS BEEN ENTERED BY IBM IN USA
PMR E0230,998,706 was updated on 96/12/13 at 13:22:13.
**************> ANSWER level 2 --> level 1 SPECIALIST <**************
====> THIS TEXT HAS BEEN ENTERED BY IBM IN USA
====> RESP: AIXOPSYS AT WTSCPOK ================= DATE:961213
TIME:0859
YOUR ADDITIONAL INFORMATION HAS BEEN RECEIVED.
**************> ANSWER level 2 --> level 1 SPECIALIST <**************
====> THIS TEXT HAS BEEN ENTERED BY IBM IN USA
====> RESP: AIXOPSYS AT WTSCPOK ================= DATE:961213
TIME:1113
RESPONSE:
The E30 and F30 require all require human interaction when
rebooting after recovering from a power failure. There is a feature
code for a Service Processor on the E30 and F30. This is an ISA card
that is plugged into an available slot. The Service Processor has a
function which allow the system to power- on after a power failure.
ENABLE/DISABLE UNATTENDED START MODE
This option may be used to instruct SP(Service Processor) to
immediately power-on after a power failure, bypassing power-on
password verification. It is intended to be used on servers that
require automatic power-on after a power failure.
Without the Service Processor, the E30 and F30 cannot
automatically reboot after a power failure has occurred.
Thank you for using AIX Technical Support.