Question:

Env:
SNA Server/6000
HCON V1.3

Desc:

When I try to start the attachment with "sna -dl linkstation"
it starts fine.  However, in HCON I am getting the "2" symbol
but not the "2B\<" symbol I am expecting.

Action: Asked SE if a callback was possible.  He said yes.
         


Response:

You might want to check your PSERVIC value on the host side, to make
sure that  session parameters are set up correctly. The parameters on 
the host side are in PSERVIC variable as follows:

PSERVIC=X'02 80 00000000 18 50 18 50 7F 00'
          -- --          -- -- -- -- --
           |  |           |  |  |  |  |
           |  |           |  |  |  |  |
           |  |           |  |  |  |  L__ screen size
           |  |           |  |  |  L_____ alternate cols
           |  |           |  |  L_____alternate rows
           |  |           |  L______primary cols
           |  |           L______primary rows
   LU type_|  L___extended data stream

   -------------
  * The Screen size field determines whether the values specified for 
    primary and alternate screen sizes will actually be used, the
    following values are valid:

      00 - undefined row and column format
      01 - 12 rows, 40 columns
      02 - 24 rows, 80 columns
      03 - Quesry device for alternate screen size
      7E - Fixed Primary size
      7F - Use primary and alternate screen sizes as defined in 
           previous 4 bytes. 