ITEM: G2225L
COMM: X25 using XTALK to AS400
Question:
I have a RS6000/340 at 3.2.4. I get 'The call has been cleared with
cause 00 and diagnostic A2' and the following is the meaning from
manual GG24-3692-00 (X25 Cookbook);
dte not operational or no application listing
What do I need to do to correct this problem?
Response:
The cause 00 means: Originated by the remote x.25 data terminal
equipment (DTE).
The diagnostics A2 means: DTE not operational (level 2) or no
application listening (network).
Both error messages are consistent and mean that the remote DTE
is down or non-operational. What is needed is to contact remote
X.25 location and verify their application or setup. This should
correct the problem.
Source: AIX V3 X.25 Communications Cookbook, GG24-3692-00 or GG24-3692-01,
Appendix D.
Response:
You stated that your local RS/6000 with X.25 connection to a AS/400
in Iceland is getting errors of Cause 00 and Diagnostics A2. Your
X.25 carriers are Sprintnet and Tymnet.
Unfortunately we can not assist you with network problems on the
remote end. As of 01/26/94, the contact phone numbers for the
carriers are listed as follows. Please call those numbers for
more assistance:
BT North America (Tymnet): 1-800-937-2862
PC Pursuit (Sprintnet): 1-800-736-1130
Thank you.