ITEM: F3261L
Netware/6000 locks up, NVT
Question:
Customer is running AIX 3.2.4 and Netware/6000. There are
25 PCs attached by ethernet. The users logged on (via NVT) to
system get a message "too many processes cannot fork" and the users
are locked up. New users can login, but they get the same
message. Using NVT, Network Virtual Terminal. The RISC System/6000
is a model 570.
Response:
Increase the maximum number of processes allowed per user. This can
be changed with the command "chdev -l sys0 -a maxuproc=100".
The smit fastpath is "smit chgsys".
Change / Show Characteristics of Operating System
Type or select values in entry fields.
Press Enter AFTER making all desired changes.
[Entry Fields]
Maximum number of PROCESSES allowed per user [40] +\#
The default is 40. Increasing this number to 100 should be sufficient.
Support Line: Netware/6000 locks up, NVT ITEM: F3261L
Dated: December 1993 Category: N/A
This HTML file was generated 99/06/24~13:30:52
Comments or suggestions?
Contact us