ITEM: F3261L

Netware/6000 locks up, NVT




Question:

Customer is running AIX 3.2.4 and Netware/6000. There are 
25 PCs attached by ethernet. The users logged on (via NVT) to
system get a message "too many processes cannot fork" and the users 
are locked up. New users can login, but they get the same 
message. Using NVT, Network Virtual Terminal. The RISC System/6000
is a model 570.

Response:

Increase the maximum number of processes allowed per user. This can
be changed with the command "chdev -l sys0 -a maxuproc=100".
The smit fastpath is "smit chgsys".

               Change / Show Characteristics of Operating System

Type or select values in entry fields.
Press Enter AFTER making all desired changes.
  
                                                        [Entry Fields]
  Maximum number of PROCESSES allowed per user       [40]                +\#

The default is 40. Increasing this number to 100 should be sufficient.