ITEM: BH3211L
Fast boot for a J30
Question:
Env:
AIX 4.1.
RISC J30
Desc:
How to do a fast ipl on a smp system
Action:
Either put this command in inittab or run from the command line:
mpcfg -cf 11 1 (command line)
Here is how to set fast IPl in Stand-By-Menu
Taken from the Service Guide for the J30
1. Place the key mode switch to service mode and press the enter
key on a termial connected to the S1 or S2 line.
2. The BUMP clears the screen on the selected line, issues a prompt
and waits for a keyword
3. Enter the keyword sbb to display the STAND-BY menu
The STAND-BY menu consists of a main menu, with several options
as shown below
0 Display Configuraiton
1 Set Flags
2 Set Unit Number
3 Set Configuration
4 SSbus Maintenance
5. I2C Maintenance
Choose option 1
This will give you some Flags you can toggle ON or toggle OFF
Remote Authorization Flag Disabled or Enabled
BUMP Console Flag Disabled or Enabled
Autoservice IPL flag Disabled or Enabled
Extended Tests parameter Disabled or Enabled
Power-On Tests in Trace Mode flag Disabled or Enabled
Power-On Tests in Loop Mode flag Disabled or Enabled
Fast IPL flag Disabled or Enabled
Set Electronic Mode Sweitch to Normal Disabled or Enabled
Then select x to exit once the flags are set
Next Action:
Closing with customer approval
Support Line: Fast boot for a J30 ITEM: BH3211L
Dated: April 1996 Category: N/A