ITEM: AH6544L
can not connect to RISC using AADU
Question:
I have AADU and DOS 6.1. When I start AADU, it gives me an error
message on the PC : C:\\drive no longer valid.
Response:
It has been a known problem. AADU on DOS 6.1 is not a zuipported
configuration. In order to make it work together, you have to do
the following on the PC:
Reboot PC and immediately press F5 to prevent CONFIG.SYS and
AUTOEXEC.BAT from being interpreted and executed.
Add the following line to the CONFIG.SYS file:
DEVICE=C:\\DOS\\SETVER.EXE
At the DOS prompt enter the following line:
setver pciinit.exe 5.00
If the DEVICE line was added in step 1, DOS will display
a warning message about loading SETVER, which can be ignored.
Reboot the PC. PCIINIT will now run successfully.
Support Line: can not connect to RISC using AADU ITEM: AH6544L
Dated: April 1995 Category: N/A
This HTML file was generated 99/06/24~13:30:27
Comments or suggestions?
Contact us