ITEM: AG6408L
Errors on vsd after power outage
Env:
sp2
virtual shared device
Desc:
When vsd was installed the devices passed all the tests run
on them.
They had a power loss last week and the ups failed as well.
Now then they are trying to back up the system. The vsd
reports errors.
They do not have oracle installed yet. (Which was the purpose
for installing vsd.)
They are working to develop processes to handle problems
like this and have several questions.
Response:
Customer had to add a script to run cfgvsd -a and startvsd -a on the
vsd nodes when they come up. Since the nodes had a power outage, the
VSDs were out of sequence. They suspended the vsds. Then ran ctlvsd -R
on each node. Finally, they ran resumevsd -a on each of the nodes.
Everything was back in sync.
Support Line: Errors on vsd after power outage ITEM: AG6408L
Dated: March 1995 Category: N/A
This HTML file was generated 99/06/24~13:30:27
Comments or suggestions?