ITEM: AB1751L

128 controller problems



Question:

AIX:  3.2.5
DESC:  128 controller problems/remote hookup/performance degraded

Response:

Env:3.2.5 560 128port
Desc:Customer says terminals on remote RAN are slow the data burst to screen.
Act: I had him get his customer on line and I had her look at EC on RAN and
all LEDs were on I had her depress both arrow keys to reset error count and
you could see the leds incrementing. I fax him new cable drawing for 
remote 128port. I had him to call PAC BELL to check lines.

NEW CABLE DRAWING

REDUCING SYNCHROUNOUS MODEM ERROR COUNTS on 128-Port Adapter

    Some modems, when used to connect Remote Async Nodes (RAN), may require
    external filtering to reduce error counts.

    NOTE:  To display the error count on the RAN, press the right arrow button
           until an "EC" is shown on the RAN LED display.  The front panel
           lights display a binary representation of the number of errors
           encountered.  This can be cleared by pressing both the left and
           right arrow buttons simultaneously thus allowing the count to start
           over.

    If high error counts are experienced, or the RAN exhibit difficulties in
    downloanding then external filters should be installed.

    Four 2200 pF capacitors (X7R 50V type) are required, two for the host
    adapter, and two for the concentrator.

    High Performance - CABLE NE
    Description:  128-Port Async Controller Cable EIA-232 Modem Cable (System).

                   System End                   Modem End
                   HD-15 (Male)                DB-25 (Male)

                     RxD  1-----(----------(----- 3 RxD
                         12-----(---Sgnd---(----- 7

                        * 5
                     RxC- 4-----(----------(-----17 RxC
                         12-----(---Sgnd---(----- 7

                     TxD- 6-----(----------(----- 2 TxD
                         12-----(--Sgnd----(----- 7

                      ** 10
                     TxC  9-----(----------(-----15 TxC
                     GND 12-----(---Sgnd---(----- 7 SG

                                              +-- 4 RTS
                                              |
                                              +-- 6 DSR
                                              |
                                              +--20 DTR

                     Shell ---------------------- 1 GND, Shell
                               Cable Shield

  NOTES:
  +  Physical connection
  (  twisted pair !!!!!!!!!!!!!!!!!!!!!!!!!!!
  *  a 2200 pf cap across pins 4 and 5
 **  a 2200 pf cap across pins 9 and 10

  .  Drain wire of cable shield tied to shells on both connector and into pin
     1 of the DB25
  .  Each signal is paired with a Sgnd (signal ground). Sgnd tied together
     at each end of the connector and on pin 7 (DB-25) and pin 12 (DB-15) on
     the other end
  .  pins 4, 6 and 20 tied together. DSR of modem will drive RTS and DTR

    CABLE NF

    Description:  128-Port Async Controller Cable EIA-232 Modem Cable (Device).


                   Modem End                     System End
                  DB-25 (Male)                  HD-15 (Female)

                     RxD  3------(--------(-------  6 RxD
                          7------(--Sgnd--(------- 12

                                                    10  *
                     RxC 17------(--------(-------  9 RxC-
                          7------(--------(------- 12

                     TxD  2------(--------(-------  1 TxD-
                          7------(--------(------- 12

                                                    5  **
                     TxC 15------(--------(-------  4 TxC
                      SG  7------(--------(------- 12 GND

                   1, Shell ----------------------  Shell
                              Cable Shield

                     RTS  4----+
                               |
                     DSR  6----+
                               |
                     DTR 20----+

  NOTES:
  +  Physical connection
  (  twisted pair !!!!!!!!!!!!!!!!!!!!!!!!!!!
  *  a 2200 pf cap across pins 4 and 5
 **  a 2200 pf cap across pins 9 and 10

  .  Drain wire of cable shield tied to shells on both connector and into pin
     1 of the DB25
  .  Each signal is paired with a Sgnd (signal ground). Sgnd tied together
     at each end of the connector and on pin 7 (DB-25) and pin 12 (DB-15) on
     the other end
  .  pins 4, 6 and 20 tied together. DSR of modem will drive RTS and DTR


    This information can be provided to a local custom cable manufacturer in
    order for them to build a cable that should solve communication errors
    (shown by the error count (EC) led on the RAN) when the RAN are connected
    via modems.

Next:closing



Support Line: 128 controller problems ITEM: AB1751L
Dated: August 1994 Category: N/A
This HTML file was generated 99/06/24~13:30:31
Comments or suggestions? Contact us