[ Previous |
Next |
Contents |
Glossary |
Home |
Search ]
The graPHIGS Programming Interface : Subroutine Reference
GPQIW - Inquire List of Images on the Workstation
GPQIW
(wsid,
start,
number,
errind,
totnum,
lindex) |
Note:
This subroutine is a Workstation State List (WSL)
inquiry.
For an overview, see
"WSL Inquiries"
Purpose
Use
GPQIW to inquire the currently defined
images on the specified workstation.
Images were defined on the workstation by the Define Image
(GPDFI)
subroutine.
If the inquired information is available, then the graPHIGS API
sets the error indicator to zero and returns the values in
the output parameters.
If the error indicator is
543 (the start value exceeds
the extent of the available data), then only the total
number (totnum) parameter is set.
If the inquired information is unavailable, then the error
indicator (errind) contains an error number indicating the
reason, and the values returned in the output parameters are
unpredictable.
Parameters
wsid -- specified by user, fullword integer
Workstation identifier.
start -- specified by user, fullword integer
Starting member of the list of indexes
of defined images (>=1)
number -- specified by user, fullword integer
Number of image indexes requested (>=0)
errind -- returned by the graPHIGS API, fullword integer
Error indicator. If the error indicator is zero, the request has been
completed. Otherwise, one of the following errors exists:
- 25
- SPECIFIED WORKSTATION DOES NOT EXIST
- 35
- WORKSTATION HAS ONLY INPUT CAPABILITIES
- 538
- START VALUE < ONE
- 539
- REQUESTED NUMBER < ZERO
- 543
- START EXCEEDS DATA EXTENT. TOTAL NUMBER AVAILABLE RETURNED
totnum -- returned by the graPHIGS API, fullword integer
Total number of defined images on the workstation.
lindex -- returned by the graPHIGS API, array of fullword integers
List of image indexes for the defined images.
Error Codes
None
Related Subroutines
- GPCAI
- Cancel Image
- GPDFI
- Define Image
RCP code
201346566
(X'0C004E06')