[ Previous |
Next |
Contents |
Glossary |
Home |
Search ]
The graPHIGS Programming Interface : Subroutine Reference
GPQISF - Inquire Input Character Set Facilities
GPQISF
(wstype,
class,
device,
start,
number,
errind,
ncsid,
csid) |
Note:
This subroutine is a Workstation Description Table (WDT)
inquiry.
For an overview, see
"WDT Inquiries"
Purpose
Use
GPQISF to inquire the character set
identifiers that are supported for the specified input
device on the specified workstation type.
The graPHIGS API returns data indicating the total number of available
character sets and their character set identifiers.
If the information is available, then the graPHIGS API sets the
error indicator to zero and returns the values in the output
parameter.
If the error indicator is
543 (the start value exceeds
the extent of the available data), then only the total
number
(totnum) parameter is set.
If the inquired information is unavailable, then the error
indicator
(errind) contains the error
number indicating the reason, and the values returned in the
output parameter are unpredictable.
Parameters
wstype -- specified by user,
8-byte character string
Workstation type.
class -- specified by user, fullword integer
Device class
(1=LOCATOR, 2=STROKE, 3=VALUATOR, 4=CHOICE, 5=PICK, 6=STRING
)
device -- specified by user, fullword integer
Device number.
start -- specified by user, fullword integer
Starting member of the list of character set identifiers
(>=1)
number -- specified by user, fullword integer
Number of character set identifiers requested
(>=0)
errind -- returned by the graPHIGS API, fullword integer
Error indicator. If the error indicator is zero, the request has been
completed. Otherwise, one of the following errors exists:
- 23
- SPECIFIED WORKSTATION TYPE DOES NOT EXIST
- 38
- WORKSTATION HAS ONLY OUTPUT CAPABILITIES
- 140
- DEVICE NUMBER < ONE OR DEVICE NOT AVAILABLE
- 328
- INPUT CLASS VALUE IS INVALID
- 538
- START VALUE < ONE
- 539
- REQUESTED NUMBER < ZERO
- 543
- START EXCEEDS DATA EXTENT. TOTAL NUMBER AVAILABLE RETURNED
- 548
- SPECIFIED WORKSTATION TYPE CANNOT BE LOADED
ncsid -- returned by the graPHIGS API, fullword integer
Total number of character set identifiers supported.
csid -- returned by the graPHIGS API, array of fullword
integers
List of supported character set identifiers.
See
Appendix A. "Character Set and Font Identifiers"
for more information.
The output array must be large enough to contain the requested data.
Error Codes
None
Related Subroutines
- GPQRCT
- Inquire Realized Connection Type
RCP code
201339667
(X'0C003313')