[ Previous | Next | Contents | Glossary | Home | Search ]
The graPHIGS Programming Interface : Subroutine Reference

GPQDVL - Inquire Default Valuator Device Data

GPQDVL (wstype, device, start, number, length, errind, ivalue, necho, echo, area, lovalue, hivalue, datalen, data)

Note:

This subroutine is a Workstation Description Table (WDT) inquiry. For an overview, see "WDT Inquiries"

Purpose

Use GPQDVL to inquire the default values of the specified valuator device for the specified workstation type.

The graPHIGS API returns the default values for the requested valuator device. For more information on default values, see The graPHIGS Programming Interface: Technical Reference

If the information is available, then the graPHIGS API sets the error indicator to zero and returns the values in the output parameter. If the error indicator indicates that an output parameter is not large enough for the requested data, then the values are available up to the length specified. If the error indicator is 533 (an output parameter is not large enough for all the requested data), then the values up to the length specified are returned. If the error indicator is 543 (the start value exceeds the extent of the available data), then only the total numb er (totnum) parameter is set. If the inquired information is unavailable, then the error indicator (errind) contains the error number indicating the reason, and the values returned in the output parameter are unpredictable.

Parameters

wstype -- specified by user, 8-byte character string

Workstation type.

device -- specified by user, fullword integer

Valuator device number.

start -- specified by user, fullword integer

Starting member of the list of prompt/echo types (>=1)

number -- specified by user, fullword integer

Number of prompt/echo types requested (>=0)

length -- specified by user, fullword integer

This refers to the length of the data array provided by the application for the graPHIGS API to return the data record, in bytes.

errind -- returned by the graPHIGS API, fullword integer

Error indicator. If the error indicator is zero, the request has been completed. Otherwise, one of the following errors exists:
23
SPECIFIED WORKSTATION TYPE DOES NOT EXIST
38
WORKSTATION HAS ONLY OUTPUT CAPABILITIES
140
DEVICE NUMBER < ONE OR DEVICE NOT AVAILABLE
509
DATA LENGTH VALUE < ZERO OR REQUIRED LENGTH
533
INQUIRY DATA EXCEEDS AREA. OUTPUT TRUNCATED
538
START VALUE < ONE
539
REQUESTED NUMBER < ZERO
543
START EXCEEDS DATA EXTENT. TOTAL NUMBER AVAILABLE RETURNED
548
SPECIFIED WORKSTATION TYPE CANNOT BE LOADED

ivalue -- returned by the graPHIGS API, short floating-point number

Default initial value.

necho -- returned by the graPHIGS API, fullword integer

Total number of available prompt/echo types.

echo -- returned by the graPHIGS API, array of fullword integers

List of available prompt/echo types. The output array must be large enough to contain the requested data.

area -- returned by the graPHIGS API, 6 short floating-point numbers (DC)

Default echo area (Xmin, Xmax, Ymin, Ymax, Zmin, Zmax)

lovalue -- returned by the graPHIGS API, short floating-point number

Default low end of range for valuator.

hivalue -- returned by the graPHIGS API, short floating-point number

Default high end of range for valuator.

datalen -- returned by the graPHIGS API, fullword integer

Default valuator data record length, in bytes.

data -- returned by the graPHIGS API, variable length data

Default valuator data record, in bytes for the default prompt/echo type (1=TYPE )

Error Codes

None

Related Subroutines

GPINVL
Initialize Valuator
GPQRCT
Inquire Realized Connection Type
GPQVL
Inquire Valuator Device State

RCP code