The graPHIGS Programming Interface : Subroutine Reference
GPQANF - Inquire Annotation Facilities
GPQANF
(wstype,
start,
number,
errind,
totnum,
styles) |
Note:
This subroutine is a Workstation Description Table (WDT)
inquiry.
For an overview, see
"WDT Inquiries"
Purpose
Use
GPQANF to inquire the list of annotation
styles that are supported by the specified workstation.
If the information is available, then the graPHIGS API sets the
error indicator to zero and returns the values in the output
parameter.
If the error indicator is
543
(the start value exceeds
the extent of the available data), then only the total
number
(totnum) parameter is set.
If the inquired information is unavailable, then the error
indicator
(errind) contains the error
number indicating the reason, and the values returned in the
output parameter are unpredictable.
Parameters
wstype -- specified by user,
8-byte character string
Workstation type.
start -- specified by user, fullword integer
Starting number of annotation styles (>=1)
number -- specified by user, fullword integer
Number of annotation styles requested (>=0)
errind -- returned by the graPHIGS API, fullword integer
Error indicator. If the error indicator is zero, the request has been
completed. Otherwise, one of the following errors exists:
- 23
- SPECIFIED WORKSTATION TYPE DOES NOT EXIST
- 35
- WORKSTATION HAS ONLY INPUT CAPABILITIES
- 538
- START VALUE < ONE
- 539
- REQUESTED NUMBER < ZERO
- 543
- START EXCEEDS DATA EXTENT. TOTAL NUMBER AVAILABLE RETURNED
- 548
- SPECIFIED WORKSTATION TYPE CANNOT BE LOADED
totnum -- returned by the graPHIGS API, fullword integer
Total number of available annotation styles.
styles -- returned by the graPHIGS API, array of fullword integers
List of annotation styles
(1=UNCONNECTED, 2=LEAD_LINE
)
Error Codes
None
Related Subroutines
- GPQRCT
- Inquire Realized Connection Type
RCP code
201346060