700-102 D 700 Description: 1.1GB single-ended disk drive
to problem.
700-114
700-116 D Description: A protocol error.
Action: Check the levels of the device,
adapter, diagnostic software, and
application software to be sure they are
all compatible. If you do not find a
problem, call your support person.
700-117 D 700 Description: A write protect error
occurred.
700-118 D 700 Description: A SCSI command time-out.
B88
700-120 D 700 Description: A SCSI error.
to
700-124
700-126 D 700 Description: A software error was caused
by a hardware failure.
B88
700-128 G 700 Description: The error log analysis
indicates a hardware failure.
700-129 G D50 Description: Error log analysis indicates
a SCSI bus problem.
700
B88
software
700-130 G 700 Description: Error log analysis indicates
a problem reported by the disk drive's self
monitoring function.
700-132 D 700 Description: A disk drive hardware error
occurred.
700-134 D B88 Description: The adapter failed to
configure.
software
700-135 D 700 Description: The device failed to
configure.
B88
software
700-136 D 700 Description: The certify operation failed.
700-137 D 700 Description: Unit attention condition has
occurred on the Send Diagnostic command.
B88
D50
701-102 D 701 Description: 1.1GB 16-bit single-ended
to disk drive problem.
701-114
701-116 D Description: A protocol error.
Action: Check the levels of the device,
adapter, diagnostic software, and
application software to be sure they are
all compatible. If you do not find a
problem, call your support person.
701-117 D 701 Description: A write protect error
occurred.
701-118 D 701 Description: A SCSI command time-out.
B88
701-120 D 701 Description: A SCSI error.
to
701-124
701-126 D 701 Description: A software error was caused
by a hardware failure.
B88
701-128 G 701 Description: The error log analysis
indicates a hardware failure.
701-129 G D50 Description: Error log analysis indicates
a SCSI bus problem.
701
B88
software
701-130 G 701 Description: Error log analysis indicates
a problem reported by the disk drive's self
monitoring function.
701-132 D 701 Description: A disk drive hardware error
occurred.
701-134 D B88 Description: The adapter failed to
configure.
software
701-135 D 701 Description: The device failed to
configure.
B88
software
701-136 D 701 Description: The certify operation failed.
701-137 D 701 Description: Unit attention condition has
occurred on the Send Diagnostic command.
B88
D50
702-102 D 702 Description: 1.1GB 16-bit differential
to disk drive problem.
702-114
702-116 D Description: A protocol error.
Action: Check the levels of the device,
adapter, diagnostic software, and
application software to be sure they are
all compatible. If you do not find a
problem, call your support person.
702-117 D 702 Description: A write protect error
occurred.
702-118 D 702 Description: A SCSI command time-out.
B88
702-120 D 702 Description: A SCSI error.
to
702-124
702-126 D 702 Description: A software error was caused
by a hardware failure.
B88
702-128 G 702 Description: The error log analysis
indicates a hardware failure.
702-129 G D50 Description: Error log analysis indicates
a SCSI bus problem.
702
B88
software
702-130 G 702 Description: Error log analysis indicates
a problem reported by the disk drive's self
monitoring function.
702-132 D 702 Description: A disk drive hardware error
occurred.
702-134 D B88 Description: The adapter failed to
configure.
software
702-135 D 702 Description: The device failed to
configure.
B88
software
702-136 D 702 Description: The certify operation failed.
702-137 D 702 Description: Unit attention condition has
occurred on the Send Diagnostic command.
B88
D50
703-102 D 703 Description: 2.2GB single-ended disk drive
to problem.
703-114
703-116 D Description: A protocol error.
Action: Check the levels of the device,
adapter, diagnostic software, and
application software to be sure they are
all compatible. If you do not find a
problem, call your support person.
703-117 D 703 Description: A write protect error
occurred.
703-118 D 703 Description: A SCSI command time-out.
B88
703-120 D 703 Description: A SCSI error.
to
703-124
703-126 D 703 Description: A software error was caused
by a hardware failure.
B88
703-128 G 703 Description: The error log analysis
indicates a hardware failure.
703-129 G D50 Description: Error log analysis indicates
a SCSI bus problem.
703
B88
software
703-130 G 703 Description: Error log analysis indicates
a problem reported by the disk drive's self
monitoring function.
703-132 D 703 Description: A disk drive hardware error
occurred.
703-134 D B88 Description: The adapter failed to
configure.
software
703-135 D 703 Description: The device failed to
configure.
B88
software
703-136 D 703 Description: The certify operation failed.
703-137 D 703 Description: Unit attention condition has
occurred on the Send Diagnostic command.
B88
D50
704-102 D 704 Description: 2.2GB 16-bit single-ended
to disk drive problem.
704-114
704-116 D Description: A protocol error.
Action: Check the levels of the device,
adapter, diagnostic software, and
application software to be sure they are
all compatible. If you do not find a
problem, call your support person.
704-117 D 704 Description: A write protect error
occurred.
704-118 D 704 Description: A SCSI command time-out.
B88
704-120 D 704 Description: A SCSI error.
to
704-124
704-126 D 704 Description: A software error was caused
by a hardware failure.
B88
704-128 G 704 Description: The error log analysis
indicates a hardware failure.
704-129 G D50 Description: Error log analysis indicates
a SCSI bus problem.
704
B88
software
704-130 G 704 Description: Error log analysis indicates
a problem reported by the disk drive's self
monitoring function.
704-132 D 704 Description: A disk drive hardware error
occurred.
704-134 D B88 Description: The adapter failed to
configure.
software
704-135 D 704 Description: The device failed to
configure.
B88
software
704-136 D 704 Description: The certify operation failed.
704-137 D 704 Description: Unit attention condition has
occurred on the Send Diagnostic command.
B88
D50
705-102 D 705 Description: 2.2GB 16-bit differential
to disk drive problem.
705-114
705-116 D Description: A protocol error.
Action: Check the levels of the device,
adapter, diagnostic software, and
application software to be sure they are
all compatible. If you do not find a
problem, call your support person.
705-117 D 705 Description: A write protect error
occurred.
705-118 D 705 Description: A SCSI command time-out.
B88
705-120 D 705 Description: A SCSI error.
to
705-124
705-126 D 705 Description: A software error was caused
by a hardware failure.
B88
705-128 G 705 Description: The error log analysis
indicates a hardware failure.
705-129 G D50 Description: Error log analysis indicates
a SCSI bus problem.
705
B88
software
705-130 G 705 Description: Error log analysis indicates
a problem reported by the disk drive's self
monitoring function.
705-132 D 705 Description: A disk drive hardware error
occurred.
705-134 D B88 Description: The adapter failed to
configure.
software
705-135 D 705 Description: The device failed to
configure.
B88
software
705-136 D 705 Description: The certify operation failed.
705-137 D 705 Description: Unit attention condition has
occurred on the Send Diagnostic command.
B88
D50
706-102 D 706 Description: 4.5GB 16-bit single-ended
to disk drive problem
706-114
706-116 D Description: A protocol error.
Action: Check the levels of the device,
adapter, diagnostic software, and
application software to be sure they are
all compatible. If you do not find a
problem, call your support person.
706-117 D 706 Description: A write protect error
occurred.
706-118 D 706 Description: A SCSI command time-out.
B88
706-120 D 706 Description: A SCSI error.
to
706-124
706-126 D 706 Description: A software error was caused
by a hardware failure.
B88
706-128 G 706 Description: The error log analysis
indicates a hardware failure.
706-129 G D50 Description: Error log analysis indicates
a SCSI bus problem.
706
B88
software
706-130 G 706 Description: Error log analysis indicates
a problem reported by the disk drive's self
monitoring function.
706-132 D 706 Description: A disk drive hardware error
occurred.
706-134 D B88 Description: The adapter failed to
configure.
software
706-135 D 706 Description: The device failed to
configure.
B88
software
706-136 D 706 Description: The certify operation failed.
706-137 D 706 Description: Unit attention condition has
occurred on the Send Diagnostic command.
B88
D50
707-102 D 707 Description: Any of the following may have
to occurred: an unrecoverable media error,
707-114 motor failed to restart, the drive did not
become ready, electronics card test failed,
bus test failed, media format failed, or
diagnostic test failed.
707-116 D Description: A protocol error.
Action: Check the levels of the device,
adapter, diagnostic software, and
application software to be sure they are
all compatible. If you do not find a
problem, call your support person.
707-117 D 707 Description: A write protect error
occurred.
707-118 D 707 Description: A SCSI command time-out.
B88
707-120 D 707 Description: A SCSI error.
to
707-124
707-126 D 707 Description: A software error was caused
by a hardware failure.
B88
707-128 G 707 Description: The error log analysis
indicates a hardware failure.
707-129 G D50 Description: Error log analysis indicates
a SCSI bus problem.
707
B88
software
707-130 G 707 Description: Error log analysis indicates
a problem reported by the disk drive's self
monitoring function.
707-132 D 707 Description: A disk drive hardware error
occurred.
707-134 D B88 Description: The adapter failed to
configure.
software
707-135 D 707 Description: The device failed to
configure.
B88
software
707-136 D 707 Description: The certify operation failed.
707-137 D 707 Description: Unit attention condition has
occurred on the Send Diagnostic command.
B88
D50
709-101 D 709 Description: Cannot run the test because
the device driver detected a hardware
error.
709-111 D 709 Description: Could not do the test because
the device driver detected a hardware
221 error.
709-112 D 709 Description: Unable to determine the type
of adapter from the VPD.
221
709-113 D 709 Description: The VPD verification test
failed.
709-114 D 709 Description: The register verification
test failed.
709-115 D 709 Description: The VPD verification test
failed.
709-116 D D57 Description: The 128-port controller line
test failed.
709
709-117 D 684 Diagnostics: Remote Async Node test
failed.
709-118 D 837 Description: Remote async node test
failed.
709-119 F 709 Description: Sync line termination test
failed.
709-151 D 837 Description: Could not perform because the
device driver detected a hardware error.
709-152 D 837 Description: The data wrap communication
test failed.
836
709-153 D 837 Description: The modem control line test
failed.
709-154 D 684 Diagnostics: Cannot run the test because
the
709 device driver detected a hardware error.
709-155 D 684 Diagnostics: The data wrap communications
test failed.
709
152
709-161 D 266 Description: Could not perform because the
device driver detected a hardware error.
709-162 D 266 Description: The data wrap communication
test failed.
709-163 D 266 Description: The modem control line test
failed.
709-164 D D06 Description: The data wrap communication
test failed.
709-171 D 259 Description: Could not perform because the
device driver detected a hardware error.
709-172 D 259 Description: The data wrap communication
test failed.
709-173 D 259 Description: The modem control line test
failed.
709-174 D 263 Description: Cannot run the test because
the device driver detected a hardware
error.
709-175 D 263 Description: The data wrap communications
test failed.
709-181 D 261 Description: Could not perform because the
device driver detected a hardware error.
709-182 D 261 Description: The data wrap communication
test failed.
709-183 D 261 Description: The modem control line test
failed.
709-251 D 709 Description: Could not perform because the
device driver detected a hardware error.
837
709-252 D 709 Description: The data wrap communication
test failed.
837
709-253 D 709 Description: The modem control line test
failed.
837
709-254 D 709 Diagnostics: Cannot run the test because
the device
684 driver detected a hardware error while
running the Remote Async Node wrap test.
709-255 D 709 Diagnostics: The data wrap communications
test failed while running the Remote Async
684 Node wrap test.
709-271 D 709 Description: Could not perform because the
device driver detected a hardware error.
837
709-272 D 709 Description: The data wrap communication
test failed.
837
709-273 D 709 Description: The modem control line test
failed.
837
709-274 D 709 Diagnostics: Cannot run the test because
the device
684 driver detected a hardware error while
running the Printer/Terminal cable wrap
test.
709-275 D 709 Diagnostics: The data wrap communications
test failed while running the
684 Printer/Terminal cable wrap test.
709-281 D 709 Description: Could not perform because the
device driver detected a hardware error.
837
709-282 D 709 Description: The data wrap communication
test failed.
837
709-283 D 709 Description: The modem control line test
failed.
837
709-481 D D56 Description: Could not do the test because
the device driver detected a hardware
error.
709-482 D D56 Description: The data wrap communication
test failed.
709-483 D D56 Description: The modem control line test
failed.
709-901 D software Description: An unexpected error occurred
that can be attributed to software or
to 709 hardware.
709-920 Action: Run diagnostics from a source other
than from the disk or a network. If the
same error occurs or if the original SRN
was not obtained from disk or a network
based diagnostics, use Chapter 12. "MAP
0210: General Problem Resolution" with a
FFC of 709; otherwise, suspect a software
problem.
709-921 D 709 Description: The adapter failed to
configure
software
709-922 D software Description: An unexpected error occurred
that can be attributed to software or
to 709 hardware.
709-924 Action: Run diagnostics from a source other
than from the disk or a network. If the
same error occurs or if the original SRN
was not obtained from disk or a network
based diagnostics, use Chapter 12. "MAP
0210: General Problem Resolution" with a
FFC of 709; otherwise, suspect a software
problem.
709-925 D 709 Description: The adapter failed to
configure
software
709-926 D software Description: An unexpected error occurred
that can be attributed to software or
to 709 hardware.
709-943 Action: Run diagnostics from a source other
than from the disk or a network. If the
same error occurs or if the original SRN
was not obtained from disk or a network
based diagnostics, use Chapter 12. "MAP
0210: General Problem Resolution" with a
FFC of 709; otherwise, suspect a software
problem.
721-102 D 721 Description: Unknown SCSI or device error.
to
721-114
721-116 D Description: A protocol error.
Action: Check the levels of the device,
adapter, diagnostic software, and
application software to be sure they are
all compatible. If you do not find a
problem, call your support person.
721-117 D 721 Description: A write protect error
occurred.
721-118 D 721 Description: A SCSI command time-out.
B88
721-120 D 721 Description: Unknown SCSI or device error.
to
721-124
721-126 D 721 Description: A software error was caused
by a hardware failure.
B88
721-128 G 721 Description: The error log analysis
indicates a hardware failure.
721-130 G 721 Description: The error log analysis
indicates a hardware failure.
B88
721-132 D 721 Description: A disk drive hardware error
occurred.
721-135 D 721 Description: The device failed to
configure.
B88
software
722-xxx D 722 Description: Unknown disk drive type is
failing.
723-xxx D 723 Description: Unknown CD-ROM type is
failing.
724-xxx D 724 Description: Unknown tape drive failure.
733-110 D 733 Description: The Reserve command failed,
or the Inquiry command failed.
to
733-120
733-130 D 733 Description: The Load command failed, or
the Unload command failed.
to media
733-135
733-140 D 733 Description: The Mode Select command
failed.
733-150 D 733 Description: The Test Unit Ready command
to failed, or the Send Diagnostic command
733-169 media failed.
733-170 D 733 Description: The Read, Write and Compare
test failed.
B88
media
733-180 D 733 Description: The Load command failed, or
the Unload command failed.
to media
733-185
733-190 D 733 Description: The Mode Select command
failed.
733-200 D 733 Description: The Test Unit Ready command
media failed.
733-210 D 733 Description: The device configuration
failed.
B88
733-220 D 733 Description: 140GB 8mm tape drive failed.
to
733-240
733-300 D 733 Description: The device configuration
failed.
software
733-310 D B88 Description: SCSI adapter configuration
733 failed.
software
733-320 G 733 Description: Error log analysis indicates
a failure.
media
733-411 D 733 Description: A reservation conflict
to occurred.
733-423 B88
software
733-511 D 733 Description: The drive returned bad or
to non-extended sense data.
733-523 B88
733-611 D 733 Description: An adapter, device, or bus
to I/O error occurred.
733-723 B88
software
734-111 D 734 Description: Unable to reserve device.
B88
734-112 D 734 Description: Unable to do configuration.
B88
734-113 D 734 Description: Unable to open the device
driver.
B88
734-121 D 734 Description: The CD-ROM drive indicates an
error.
734-122 D 734 Description: The CD-ROM drive indicates an
error.
734-123 D 734 Description: The CD-ROM drive indicates an
error.
734-125 D 734 Description: The CD-ROM drive indicates an
error.
B88
734-126 D 734 Description: The CD-ROM drive indicates an
error.
734-127 D 734 Description: The CD-ROM drive indicates an
error.
734-128 D 734 Description: The CD-ROM drive indicates an
error.
734-129 D 734 Description: The CD-ROM drive indicates an
error.
734-150 D Media Description: A media error was detected.
734
734-151 D 734 Description: A command timeout was
detected.
D88
734-152 D 734 Description: A command reservation
conflict was detected.
734-162 D 734 Description: The CD-ROM drive indicates an
error.
734-171 D 734 Description: Unable to reserve device.
734-172 D 734 Description: Unable to do configuration.
734-173 D 734 Description: Unable to open device driver.
734-175 D 734 Description: The CD-ROM drive indicates an
error.
734-198 D 734 Description: Undefined error detected.
B88
734-199 D 734 Description: Undefined error detected.
734-211 D 734 Description: The LED test failed.
734-281 D 734 Description: No tone during audio test.
734-301 G 734 Description: Errors found during ELA.
734-302 G 734 Description: Errors found during ELA.
B88
736-101 D 821 Description: An unexpected adapter error
occurred.
736-102 D 736 Description: An unexpected device or
adapter error occurred.
821
736-103 D 736 Description: The keyboard reset failed.
821
736-104 D 736 Description: Unknown keyboard.
736-105 D 736 Description: The keyboard light on test
failed.
821
736-106 D 736 Description: The keyboard light off test
failed.
821
736-201 D 821 Description: An unexpected adapter error
occurred.
736-202 D 736 Description: An unexpected device or
adapter error occurred.
821
736-203 D 736 Description: The read keyboard ID test
failed.
821
736-204 D 736 Description: The keyboard layout ID test
failed.
736-205 D 736 Description: The keyboard echo test
failed.
821
736-206 D 736 Description: The select scan code set test
failed.
821
736-301 D 821 Description: An unexpected adapter error
occurred.
736-302 D 736 Description: An unexpected device or
adapter error occurred.
736-303 D 736 Description: An error occurred in turning
on the lamps.
736-304 D 736 Description: An error occurred in turning
off the lamps.
736-401 D 821 Description: An unexpected adapter error
occurred.
736-402 D 736 Description: An unexpected device or
adapter error occurred.
821
736-403 D 736 Description: Unable to recognize the
keyboard.
736-404 D 736 Description: The keyboard is failing.
821
736-701 D 736 Description: Error configuring the device.
821
736-901 G 821 Description: The error log analysis
indicates an adapter failure.
736-902 G 736 Description: The error log analysis
indicates a device failure.
821
736-903 G 736 Description: The error log analysis
indicates an unknown failure.
821
741-102 D 741 Description: SCSI disk drive problems.
to
741-114
741-116 D Description: A protocol error.
Action: Check the levels of the device,
adapter, diagnostic software, and
application software to be sure they are
all compatible. If you do not find a
problem, call your support person.
741-117 D 741 Description: A write protect error
occurred.
741-118 D 741 Description: A SCSI command timeout.
B88
741-120 D 741 Description: SCSI disk drive problems.
to
741-124
741-126 D 741 Description: A software error was caused
by a hardware failure.
B88
741-128 G 741 Description: The error log analysis
indicates a hardware failure.
741-129 G D50 Description: Error log analysis indicates
a SCSI bus problem.
741
B88
software
741-130 G 741 Description: Error log analysis indicates
a problem reported by the disk drive's self
monitoring function.
741-132 D 741 Description: A disk drive hardware error
occurred.
741-134 D B88 Description: The adapter failed to
configure.
software
741-135 D 741 Description: The device failed to
configure.
B88
software
741-137 D 741 Description: Unit attention condition has
occurred on the Send Diagnostic command.
B88
D50
742-101 D 742 Description: Configuration register test
failed
742-102 D 742 Description: I/O register test failed
742-104 D 742 Description: Internal loopback test failed
742-105 D 742 Description: Internal loopback test failed
742-106 D 742 Description: External loopback test failed
742-121 D D59 Description: Configuration register test
failed
742-122 D D59 Description: I/O register test failed
742-124 D D59 Description: Internal loopback test failed
742-125 D D59 Description: Internal loopback test failed
742-126 D D59 Description: External loopback test failed
742-141 D D60 Description: Configuration register test
failed
742-142 D D60 Description: I/O register test failed
742-144 D D60 Description: Internal loopback test failed
742-145 D D60 Description: Internal loopback test failed
742-160 D B08 Description: 10Base-T transceiver test
failed
742-161 D B09 Description: 10Base-2 transceiver test
failed
742-203 D 742 Description: Device configuration failed
software
742-223 D D59 Description: Device configuration failed
software
742-224 D B08 Description: 10 Base-T transceiver test
failed
D59
742-225 D B09 Description: 10 Base-2 transceiver test
failed
D59
742-243 D D60 Description: Device configuration failed
software
742-700 G 742 Description: Error log analysis indicates
a hardware problem
software
742-720 G D59 Description: Error log analysis indicates
a hardware problem
software
742-740 G D60 Description: Error log analysis indicates
a hardware problem
software
745-100 D media Description: Recovered error.
Action: No action required.
745
745-200 D media Description: Drive Not Ready.
Action: Install media, refer to the tape
745 autoloader service guide.
745-300 D media Description: 4mm Tape Auto Loader problem.
to
745-350 745 Action: Replace media, clean drive, refer
to the tape autoloader service guide.
745-400 D 745 Description: General Hardware Failure.
Action: Replace media, clean drive, refer
magazine to the tape autoloader service guide.
media
745-410 D 745 Description: Internal Hardware Failure
to Action: Replace drive, refer to the tape
745-435 media autoloader service guide.
745-440 D 745 Description: SCSI Hardware Failure.
Action: Replace drive, refer to the tape
SCSI autoloader service guide.
Adapter
745-441 D 745 Description: 4mm Tape Auto Loader problem.
to
745-443 media Action: Replace drive, refer to the tape
autoloader service guide.
745-444 D 745 Description: Humidity too High
Action: Lower humidity, replace media,
environ- refer to the tape autoloader service guide.
ment
media
745-445 D clean Description: Drive Requires Cleaning
Action: Clean drive, replace media, refer
media to the tape autoloader service guide.
drive
745-460 D 745 Description: Magazine Movement Failure
to Action: Check magazine and media, clean
745-465 magazine rollers, refer to the tape autoloader
service guide.
media
745-470 D 745 Description: Media Insert/Eject Failure
to Action: Check clean magazine and media,
745-475 magazine clean rollers, refer to the tape autoloader
service guide.
media
745-480 D 745 Description: Drawer Open/Close Failure
to Action: Check magazine and media, refer to
745-485 magazine the tape autoloader service guide.
media
745-500 D 745 Description: Illegal request to drive
Action: Software conflict, refer to the
system tape autoloader service guide.
745-600 D 745 Description: Unit Attention
Action: Software conflict, media changed,
system refer to the tape autoloader service guide.
745-700 D 745 Description: Not Writeable
Action: Check media for write protect,
media refer to the tape autoloader service guide.
745-800 D 745 Description: Blank Media
Action: Check media, refer to the tape
media autoloader service guide.
745-B00 D 745 Description: SCSI Interface Failure
Action: Check SCSI interface, refer to the
SCSI tape autoloader service guide.
Adapter
745-D00 D 745 Description: Tape Full
Action: Check replace media, refer to the
media tape autoloader service guide.
746-212 D 746 Description: FIFO empty bit set.
Action: Go to Chapter 7. "MAP 0050: SCSI
221 Problems Isolation Procedure".
746-213 D 746 Description: FIFO empty bit clear.
Action: Go to Chapter 7. "MAP 0050: SCSI
221 Problems Isolation Procedure".
746-214 D 746 Description: FIFO full bit set.
Action: Go to Chapter 7. "MAP 0050: SCSI
221 Problems Isolation Procedure".
746-215 D 746 Description: FIFO full bit clear.
Action: Go to Chapter 7. "MAP 0050: SCSI
221 Problems Isolation Procedure".
746-216 D 746 Description: FIFO data miscompare.
Action: Go to Chapter 7. "MAP 0050: SCSI
221 Problems Isolation Procedure".
746-217 D 746 Description: SCSI FIFO data miscompare.
Action: Go to Chapter 7. "MAP 0050: SCSI
221 Problems Isolation Procedure".
746-218 D 746 Description: SCSI FIFO underflow.
Action: Go to Chapter 7. "MAP 0050: SCSI
221 Problems Isolation Procedure".
746-219 D 746 Description: SCSI parity error.
Action: Go to Chapter 7. "MAP 0050: SCSI
221 Problems Isolation Procedure".
746-220 D 746 Description: SCSI FIFO flags error.
Action: Go to Chapter 7. "MAP 0050: SCSI
221 Problems Isolation Procedure".
746-221 D 746 Description: Miscompare during the
write/read of the configuration register.
221 Action: Go to Chapter 7. "MAP 0050: SCSI
Problems Isolation Procedure".
746-222 D 746 Description: Error during the write/read
of the memory register.
221 Action: Go to Chapter 7. "MAP 0050: SCSI
Problems Isolation Procedure".
746-223 D 746 Description: Miscompare during the
write/read of the memory I/O register.
221 Action: Go to Chapter 7. "MAP 0050: SCSI
Problems Isolation Procedure".
746-224 D 746 Description: Error reading the PCI
configuration register.
221
746-225 D 746 Description: Adapter POST failed.
221
746-230 D D50 Description: Arbitration test failed.
Action: Go to Chapter 7. "MAP 0050: SCSI
746 Problems Isolation Procedure".
746-231 D D50 Description: Function could not complete.
Action: Go to Chapter 7. "MAP 0050: SCSI
746 Problems Isolation Procedure".
746-232 D D50 Description: SCSI bus data miscompare.
Action: Go to Chapter 7. "MAP 0050: SCSI
746 Problems Isolation Procedure".
746-240 D 746 Description: No terminal power.
Action: Go to Chapter 7. "MAP 0050: SCSI
221 Problems Isolation Procedure".
746-301 D 746 Description: Configuration open failed for
parent bus.
D50
software
746-700 G 746 Description: Error log analysis indicates
a PCI SCSI adapter failure.
software
746-701 G 746 Description: Error log analysis indicates
a PCI SCSI adapter failure.
software
746-702 G 746 Description: Error log analysis indicates
a PCI SCSI adapter failure.
software
746-703 G 746 Description: Error log analysis indicates
a PCI SCSI adapter failure.
software
746-704 G 746 Description: Error log analysis indicates
a PCI SCSI adapter failure.
software
746-705 G 746 Description: Error log analysis indicates
a PCI SCSI adapter failure.
software
746-800 G 746 Description: Error log analysis indicates
a PCI SCSI adapter PTC failure.
Action: Go to Chapter 7. "MAP 0050: SCSI
Problems Isolation Procedure".
746-802 G 746 Description: Error log analysis indicates
a PCI SCSI bus failure.
Action: Go to Chapter 7. "MAP 0050: SCSI
Problems Isolation Procedure".
747-212 D 747 Description: FIFO empty bit set.
Action: Go to Chapter 7. "MAP 0050: SCSI
221 Problems Isolation Procedure".
747-213 D 747 Description: FIFO empty bit clear.
Action: Go to Chapter 7. "MAP 0050: SCSI
221 Problems Isolation Procedure".
747-214 D 747 Description: FIFO full bit set.
Action: Go to Chapter 7. "MAP 0050: SCSI
221 Problems Isolation Procedure".
747-215 D 747 Description: FIFO full bit clear.
Action: Go to Chapter 7. "MAP 0050: SCSI
221 Problems Isolation Procedure".
747-216 D 747 Description: FIFO data miscompare.
Action: Go to Chapter 7. "MAP 0050: SCSI
221 Problems Isolation Procedure".
747-217 D 747 Description: SCSI FIFO data miscompare.
Action: Go to Chapter 7. "MAP 0050: SCSI
221 Problems Isolation Procedure".
747-218 D 747 Description: SCSI FIFO underflow.
Action: Go to Chapter 7. "MAP 0050: SCSI
221 Problems Isolation Procedure".
747-219 D 747 Description: SCSI parity error.
Action: Go to Chapter 7. "MAP 0050: SCSI
221 Problems Isolation Procedure".
747-220 D 747 Description: SCSI FIFO flags error.
Action: Go to Chapter 7. "MAP 0050: SCSI
221 Problems Isolation Procedure".
747-221 D 747 Description: Miscompare during the
write/read of the configuration register.
221 Action: Go to Chapter 7. "MAP 0050: SCSI
Problems Isolation Procedure".
747-222 D 747 Description: Error during the write/read
of the memory register.
221 Action: Go to Chapter 7. "MAP 0050: SCSI
Problems Isolation Procedure".
747-223 D 747 Description: Miscompare during the
write/read of the memory I/O register.
221 Action: Go to Chapter 7. "MAP 0050: SCSI
Problems Isolation Procedure".
747-224 D 747 Description: Error reading the PCI
configuration register.
221
747-225 D 747 Description: Adapter POST failed.
221
747-230 D D50 Description: Arbitration test failed.
Action: Go to Chapter 7. "MAP 0050: SCSI
747 Problems Isolation Procedure".
747-231 D D50 Description: Function could not complete.
Action: Go to Chapter 7. "MAP 0050: SCSI
747 Problems Isolation Procedure".
747-232 D D50 Description: SCSI bus data miscompare.
Action: Go to Chapter 7. "MAP 0050: SCSI
747 Problems Isolation Procedure".
747-240 D 747 Description: No terminal power.
Action: Go to Chapter 7. "MAP 0050: SCSI
221 Problems Isolation Procedure".
747-301 D 747 Description: Configuration open failed for
parent bus.
D50
software
747-700 G 747 Description: Error log analysis indicates
a PCI SCSI adapter failure.
software
747-701 G 747 Description: Error log analysis indicates
a PCI SCSI adapter failure.
software
747-702 G 747 Description: Error log analysis indicates
a PCI SCSI adapter failure.
software
747-703 G 747 Description: Error log analysis indicates
a PCI SCSI adapter failure.
software
747-704 G 747 Description: Error log analysis indicates
a PCI SCSI adapter failure.
software
747-705 G 747 Description: Error log analysis indicates
a PCI SCSI adapter failure.
software
747-800 G 747 Description: Error log analysis indicates
a PCI SCSI adapter PTC failure.
Action: Go to Chapter 7. "MAP 0050: SCSI
Problems Isolation Procedure".
747-802 G 747 Description: Error log analysis indicates
a PCI SCSI bus failure.
Action: Go to Chapter 7. "MAP 0050: SCSI
Problems Isolation Procedure".
749-xxx D 749 Description: 7331 Model 205 Tape Library.
Refer to service documentation for this
device.
750-100 D 750 Description: The adapter open test failed.
750-200 D 750 Description: Config register test failed.
221
750-201 D 750 Description: I/O register test failed.
221
750-202 D 750 Description: Adapter self-test failed.
221
750-300 D 256 Description: The connect test failed.
750
221
750-301 D 256 Description: Token-ring internal wrap test
failure.
750
221
750-302 D 256 Description: Token-ring external wrap
failure
750
221
750-303 D 256 Description: Token-ring initialization
test failure
750
221
750-400 D 240 Description: The connect test failed.
256
750
221
750-401 D 240 Token-ring internal wrap test failure
256
750
221
750-402 D 240 Token-ring external wrap test failure
256
750
221
750-403 D 240 Token-ring initialization test failure
256
750
221
750-700 G 750 Description: Error Log analysis indicated
a hardware failure.
221
751-101 D 751 Description: The PCI wrap test failed
227
751-102 D 751 Description: The POST indicates an adapter
failure.
751-103 D 751 Description: The POST indicates an adapter
channel failure.
751-104 D Cable Description: The POST indicates a
defective cable.
751-105 D Backplane/ Description: The POST indicates a
defective backplane or external enclosure.
Ext.Encl Action: If the disk devices are located in
an external enclosure, refer to the service
documentation for the external enclosure.
751-106 D Disk Description: The POST indicates a disk
failure.
751-107 D 751 Description: The POST indicates a firmware
failure.
751-108 D 751 Description: The NVRAM test indicates an
adapter firmware failure.
751-109 D 751 Description: The NVRAM test indicates an
adapter failure.
751-110 D Disk Description: The disk reported a
Predictive Failure Analysis error (PFA).
751-111 D Disk Description: The disk drive has been
failed by the adapter.
751-112 G Disk Description: ELA indicates that the disk
reported a irrecoverable equipment error.
751-113 G Disk Description: ELA indicates that the disk
reported a irrecoverable data error.
757-110 D 757 Description: The Reserve command failed.
757-120 D 757 Description: The Inquiry command failed.
757-130 D 757 Description: The Load command failed.
media
757-135 D 757 Description: The Unload command failed.
media
757-140 D 757 Description: The Mode Select command
failed.
757-150 D 757 Description: The Test Unit Ready command
failed.
media
757-160 D 757 Description: The Send Diagnostic command
failed.
media
757-169 D 757 Description: The send diagnostic command
failed.
media
757-170 D 757 Description: The Read, Write and Compare
test failed.
B88
media
757-180 D 757 Description: The Load command failed.
media
757-185 D 757 Description: The Unload command failed.
media
757-190 D 757 Description: The Mode Select command
failed.
757-200 D 757 Description: The Test Unit Ready command
failed.
media
757-210 D 757 Description: The device configuration
failed.
B88
757-220 D 757 Description: The Release command failed.
757-230 D 757 Description: The Request Sense command
failed.
757-240 D 757 Description: The Openx command failed.
757-300 D 757 Description: The device configuration
failed.
software
757-310 D B88 Description: SCSI adapter configuration
failed.
757
software
757-320 D 757 Description: Error log analysis indicates
a failure.
media
757-411 D 757 Description: A reservation conflict
to occurred.
757-423 B88
software
757-511 D 757 Description: The drive returned bad or
to non-extended sense data.
757-523 B88
757-611 D 757 Description: An adapter or bus I/O error
to occurred.
757-623 B88
software
757-711 D 757 Description: A device timeout error
to occurred.
757-723 B88
software
772-098 Description: Disk drive indicates an
J 772 error.
B88
772-099 Description: Disk drive not found.
J 772
B88
772-102 Description: An unrecoverable media error.
D 772
772-104 Description: The motor failed to restart.
D 772
772-105 Description: The drive did not become
D 772 ready.
772-106 Description: The electronics card test
D 772 failed.
772-108 Description: The bus test failed.
D 772
772-110 Description: The media format is
D 772 corrupted.
772-112 Description: The diagnostic test failed.
D 772
772-114 Description: An unrecoverable hardware
D 772 error.
772-116 Description: A protocol error.
D Action: Check the levels of the device,
adapter, diagnostic software, and
application software to be sure they are
all compatible. If you do not find a
problem, call your support person.
772-117 Description: A write protect error
D 772 occurred.
772-118 Description: A SCSI command time-out.
D 772
B88
772-120 Description: A SCSI busy or command error.
D 772
772-122 Description: A SCSI reservation conflict
D 772 error.
772-124 Description: A SCSI check condition error.
D 772
772-126 Description: A software error was caused
D 772 by a hardware failure.
B88
772-128 Description: The error log analysis
G 772 indicates a hardware failure.
772-129 G D50 Description: Error log analysis indicates
a SCSI bus problem.
772
B88
software
772-130 G 772 Description: Error log analysis indicates
a problem reported by the disk drive's self
monitoring function.
772-132 Description: A disk drive hardware error
D 772 occurred.
772-134 Description: The adapter failed to
D B88 configure.
software
772-135 D 772 Description: The device failed to
B88 configure.
software
772-136 Description: The certify operation failed.
D 772
772-137 D 772 Description: Unit attention condition has
occurred on the Send Diagnostic command.
B88
D50
773-098 Description: Disk drive indicates an
J 773 error.
B88
773-099 Description: Disk drive not found.
J 773
B88
773-102 Description: An unrecoverable media error.
D 773
773-104 Description: The motor failed to restart.
D 773
773-105 Description: The drive did not become
D 773 ready.
773-106 Description: The electronics card test
D 773 failed.
773-108 Description: The bus test failed.
D 773
773-110 Description: The media format is
D 773 corrupted.
773-112 Description: The diagnostic test failed.
D 773
773-114 Description: An unrecoverable hardware
D 773 error.
773-116 Description: A protocol error.
D Action: Check the levels of the device,
adapter, diagnostic software, and
application software to be sure they are
all compatible. If you do not find a
problem, call your support person.
773-117 Description: A write protect error
D 773 occurred.
773-118 Description: A SCSI command time-out.
D 773
B88
773-120 Description: A SCSI busy or command error.
D 773
773-122 Description: A SCSI reservation conflict
D 773 error.
773-124 Description: A SCSI check condition
D 773 error.
773-126 Description: A software error was caused
D 773 by a hardware failure.
B88
773-128 Description: The error log analysis
G 773 indicates a hardware failure.
773-129 G D50 Description: Error log analysis indicates
a SCSI bus problem.
773
B88
software
773-130 G 773 Description: Error log analysis indicates
a problem reported by the disk drive's self
monitoring function.
773-132 Description: A disk drive hardware error
D 773 occurred.
773-134 Description: The adapter failed to
D B88 configure.
software
773-135 D 773 Description: The device failed to
B88 configure.
software
773-136 Description: The certify operation failed.
D 773
773-137 D 773 Description: Unit attention condition has
occurred on the Send Diagnostic command.
B88
D50
774-098 J 774 Description: Disk drive indicates an
error.
B88
774-099 Description: Disk drive not found.
J 774
B88
774-102 Description: An unrecoverable media error.
D 774
774-104 Description: The motor failed to restart.
D 774
774-105 Description: The drive did not become
D 774 ready.
774-106 Description: The electronics card test
D 774 failed.
774-108 Description: The bus test failed.
D 774
774-110 Description: The media format is
D 774 corrupted.
774-112 Description: The diagnostic test failed.
D 774
774-114 Description: An unrecoverable hardware
D 774 error.
774-116 Description: A protocol error.
D Action: Check the levels of the device,
adapter, diagnostic software, and
application software to be sure they are
all compatible. If you do not find a
problem, call your support person.
774-117 Description: A write protect error
D 774 occurred.
774-118 Description: A SCSI command time-out.
D 774
B88
774-120 Description: A SCSI busy or command error.
D 774
774-122 Description: A SCSI reservation conflict
D 774 error.
774-124 Description: A SCSI check condition
D 774 error.
774-126 Description: A software error was caused
D 774 by a hardware failure.
B88
774-128 Description: The error log analysis
G 774 indicates a hardware failure.
774-129 G D50 Description: Error log analysis indicates
a SCSI bus problem.
774
B88
software
774-130 G 774 Description: Error log analysis indicates
a problem reported by the disk drive's self
monitoring function.
774-132 Description: A disk drive hardware error
D 774 occurred.
774-134 Description: The adapter failed to
D B88 configure.
software
774-135 D 774 Description: The device failed to
B88 configure.
software
774-136 Description: The certify operation failed.
D 774
774-137 D 774 Description: Unit attention condition has
occurred on the Send Diagnostic command.
B88
D50
775-001 D 775 Description: "NO" to color panel
227
Monitor
775-002 D 775 Description: "NO" to cursor panel
Monitor
775-007 D Info code Description: The EMC_SCROLLING_17_H_TEST
failed
775-009 D Info code Description: The EMC_SCROLLING_21_H_TEST
failed
775-064 D 775 Description: TRIO64V+_TIMEOUT
227
775-101 D 775 Description: Color miscompare
227
775-102 D 775 Description: Clipping error
227
775-103 D 775 Description: Rectangle fill test failed
227
775-128 D software Description: MALLOC_ERROR
775
775-161 D software Description: Loop count value in rules
file is zero
775-191 D 775 Description: Red screen error
227
775-193 D 775 Description: Green screen error
227
775-1FF D 775 Description: Rectangle fill test failed
227
775-201 D 775 Description: Color miscompare
227
775-202 D 775 Description: Clipping error
227
775-203 D 775 Description: Image transfer across Plane
Test failed
227
775-211 D software Description: INTERNAL_ERROR_DATA_SIZE
775-212 D software Description: INTERNAL_ERROR_NO_ACCESS
775-215 D 775 Description: Black screen error
227
775-217 D 775 Description: 9 x 7 Cross hatch grid
failed.
227
775-233 D software Description: OPEN_RCM_ERROR
775-234 D software Description: IOCTL_GSC_HANDLE_FAILED
775-235 D software Description: AIXGSC_MAKE_GP_FAILED
775-236 D software Description: AIXGSC_UNMAKE_GP_FAILED
775-237 D software Description: DEVICE_BUSY_ERROR
775-241 D Info code Description: The SCROLLING_17_H_TEST
failed.
775-263 D Info code Description: The EMC_SCROLLING_21_H_TEST
failed
775-2FF D 775 Description: Image transfer across Plane
Test failed
227
775-301 D 775 Description: A write of "0x00" to the
palette register failed
227
775-302 D 775 Description: A write of "0x15" to the
palette register failed
227
775-303 D 775 Description: A write of "0x2A" to the
palette register failed
227
775-304 D 775 Description: A write of "0x3F" to the
palette register failed
227
775-305 D 775 Description: The test of the palette
registers failed
227
775-3FF D 775 Description: The test of the palette
registers failed
227
775-401 D 775 Description: Frame buffer base address
inconsistent
227
775-402 D 775 Description: VRAM inaccessible
227
775-403 D 775 Description: Miscompare found in VRAM
227
775-404 D 775 Description: The test of the VRAM failed
227
775-447 D 775 Description: Green screen error
227
775-449 D 775 Description: Blue Screen error
227
775-471 D 775 Description: 9 x 7 Cross hatch grid
failed.
227
775-473 D 775 Description: 11 x 9 Cross hatch grid
failed.
227
775-495 D Info code Description: The SCROLLING_17_H_TEST
failed.
775-497 D Info code Description: The SCROLLING_21_H_TEST
failed.
775-4FF D 775 Description: The test of the VRAM failed
227
775-501 D 775 Description: Color miscompare
227
775-502 D 775 Description: Clipping error
227
775-503 D 775 Description: Direct Frame Buffer test
failed
227
775-5FF D 775 Description: Direct Frame Buffer test
failed
227
775-601 D 775 Description: Video Stream Register test
failed
227
775-602 D 775 Description: Video Stream hardware test
failed
227
775-6FF D 775 Description: Video Stream hardware test
failed
227
775-701 D 775 Description: 0 Degree Short Stroke Draw
failed
227
775-702 D 775 Description: 45 Degree Short Stroke Draw
failed
227
775-703 D 775 Description: Blue Screen error, or 90
Degree Short Stroke Draw failed
227
775-704 D 775 Description: 135 Degree Short Stroke Draw
failed
227
775-705 D 775 Description: White screen error, or 180
Degree Short Stroke Draw failed
227
775-706 D 775 Description: 225 Degree Short Stroke Draw
failed
227
775-707 D 775 Description: 270 Degree Short Stroke Draw
failed
227
775-708 D 775 Description: 315 Degree Short Stroke Draw
failed
227
775-709 D 775 Description: Short Stroke Vector Function
test failed
227
775-727 D 775 Description: 11 x 9 Cross hatch grid
failed.
227
775-750 D Info code Description: The SCROLLING_21_H_TEST
failed.
775-753 D Info code Description: The EMC_SCROLLING_17_H_TEST
failed
775-7FE D 775 Description: Short Stroke Vector Function
test failed
227
775-7FF D software Description: Bad vector detected
775
227
775-801 D 775 Description: Color for PatBlt thru screen
failed
227
775-802 D 775 Description: Clipping for PatBlt thru
screen failed
227
775-803 D 775 Description: Color for PatBlt Across
screen failed
227
775-804 D 775 Description: Clipping for PatBlt Across
screen failed
227
775-805 D 775 Description: Pattern Fill Across the Plane
test failed
227
775-8FF D 775 Description: Pattern Fill Across the Plane
test failed
227
775-901 D 775 Description: Color miscompare of white
boxes detected
227
775-902 D 775 Description: Clipping error of white boxes
detected
227
775-903 D 775 Description: Color miscompare of color
bars detected
227
775-904 D 775 Description: Clipping error of white boxes
detected
227
775-905 D 775 Description: Color miscompare of white
boxes detected
227
775-906 D 775 Description: Clipping error of white boxes
detected
227
775-907 D 775 Description: Color miscompare of white
boxes detected
227
775-908 D 775 Description: Clipping miscompare of white
boxes detected
227
775-909 D 775 Description: The Area fill test (color
bars) failed
227
775-9FF D 775 Description: The Area fill test (color
bars) failed
227
775-937 D 775 Description: Red screen error
227
775-959 D 775 Description: White screen error
227
775-961 D 775 Description: Black screen error
227
775-A01 D 775 Description: Color miscompare of
horizontal top line
227
775-A02 D 775 Description: Clipping error of horizontal
top line
227
775-A03 D 775 Description: Color miscompare of vertical
right line
227
775-A04 D 775 Description: Clipping error of vertical
right line
227
775-A05 D 775 Description: Color miscompare of
horizontal bottom line
227
775-A06 D 775 Description: Clipping error of horizontal
bottom line
227
775-A07 D 775 Description: Color miscompare of vertical
left line
227
775-A08 D 775 Description: Clipping error of vertical
left line
227
775-A09 D 775 Description: Color miscompare of
horizontal center line
227
775-A0A D 775 Description: Clipping error of horizontal
center line
227
775-A0B D 775 Description: Color miscompare of vertical
center line
227
775-A0C D 775 Description: Clipping error of vertical
center line
227
775-A0D D 775 Description: Reserved
227
775-A0F D 775 Description: Reserved
227
775-A10 D 775 Description: Color miscompare of textured
top line
227
775-A11 D 775 Description: Clipping error of textured
top line
227
775-A12 D 775 Description: Line Drawing Function test
failed
227
775-AFF D 775 Description: Line Drawing Function test
failed
227
775-B01 D 775 Description: Rectangle Area Color
miscompare detected
227
775-B02 D 775 Description: Rectangle Area Clip error
detected
227
775-B03 D 775 Description: Clipped Area Horizontal color
miscompare (background line color wrong)
227
775-B04 D 775 Description: Clipped Area Horizontal clip
miscompare (clip of background line wrong)
227
775-B05 D 775 Description: Clipped Area Vertical color
miscompare (background line color wrong)
227
775-B06 D 775 Description: Clipped Area Vertical clip
error (clip of background line wrong)
227
775-B07 D 775 Description: The clipping function test
failed.
227
775-BFF D 775 Description: The clipping function test
failed.
227
775-C01 D 775 Description: The BIOS read failed.
227
775-C02 D 775 Description: The BIOS function test
failed.
227
775-CFF D 775 Description: The BIOS function test
failed.
227
775-D01 D 775 Description: The HW cursor function test
failed.
227
775-DFF D 775 Description: The HW cursor function test
failed.
227
776-104 D D46 Description: Connect Test Failure
776-105 D D46 Description: Wrap Test Failure
776-106 D D46 Description: Wrap Test Failure
776-201 D 776 Description: Configuration Register Test
Failure
221
776-202 D 776 Description: I/O Test Failure
221
776-203 D 776 Description: Adapter On-Card Test Failure
221
776-204 D 776 Description: Connect Test Failure
221
776-205 D 776 Description: Wrap Test Failure
221
776-206 D 776 Description: Wrap Test Failure
221
776-304 D D46 Description: Connect Wrap Test Failure
776
221
776-305 D D46 Description: Wrap Test Failure
776
221
776-306 D D46 Description: Wrap Test Failure
776
221
776-404 D 240 Description: Connect Test Failure
D46
776
221
776-405 D 240 Description: Wrap Test Failure
D46
776
221
776-406 D 240 Description: Wrap Test Failure.
D46
776
221
776-414 F 240 Description: Connect Test Failure. This
failure occurs if not connected to a
D46 functional Token-Ring network.
Action: Run advanced diagnostics for this
776 resource to obtain correct problem
isolation.
221
776-415 F 240 Description: Wrap Test Failure. This
failure occurs if not connected to a
D46 functional Token-Ring network.
Action: Run advanced diagnostics for this
776 resource to obtain correct problem
isolation.
221
776-416 F 240 Description: Wrap Test Failure. This
failure occurs if not connected to a
D46 functional Token-Ring network.
Action: Run advanced diagnostics for this
776 resource to obtain correct problem
isolation.
221
776-702 G 776 Description: ELA indicates a Token-Ring
adapter check.
221
776-703 G 776 Description: ELA indicates that the
Token-Ring device driver has experienced a
221 DMA failure
776-704 G 776 Description: ELA indicates that the
Token-Ring device driver has experienced a
221 PCI bus failure
776-705 G 776 Description: ELA indicates that the
Token-Ring device driver has seen a
221 Programmed I/O (PIO) failure.
777-201 D 777 Description: Configuration Register Test
Failure
221
777-202 D 777 Description: I/O Test Failure
221
777-203 D 777 Description: Adapter initialization test
failure
221
777-204 D 777 Description: Internal wrap test failure
221
777-205 D 777 Description: Internal wrap test failure
221
777-206 D 777 Description: External wrap (10Mbps) test
failure
221
777-207 D 777 Description: Internal wrap test failure
221
777-208 D 777 Description: External wrap (100Mbps) test
failure
221
777-701 G 777 Description: Error log analysis indicates
that the adapter is not responding to
221 initialization commands.
777-702 G 777 Description: Error Log Analysis indicates
that the device driver has detected a PIO
221 error which it was unable to correct.
777-703 G 777 Description: Error log analysis indicates
that the adapter has been shut down due to
221 an unrecoverable error.
777-704 G 777 Description: Error Log Analysis indicates
a problem with the EEPROM on the adapter
221
780-101 D 780 Description: Adapter logic test failure.
227
780-102 D 780 Description: Adapter logic test failure.
780-109 D 780 Description: Adapter channel Input/Output
test failure.
780-113 D 780 Description: Adapter Serial Communication
Controller (SCC) test failure.
780-114 D 780 Description: Adapter logic test failure.
227
780-120 D 780 Description: Adapter could not be detected
or configured.
227
software
780-140 D 271 Description: An error was found with the
X.21 interface adapter cable.
780
780-150 D 272 Description: An error was found with the
X.24 interface adapter cable.
780
780-160 D 273 Description: An error was found with the
X.35 interface adapter cable.
780
780-170 D 780 Description: The adapter hardware failed.
780-180 D 780 Description: The adapter hardware failed.
780-190 D 780 Description: The adapter hardware failed.
780-210 D 780 Description: An error was found on the
adapter.
185
780-211 D 780 Description: The adapter card POST test
failed.
227
780-230 D 780 Description: The adapter card hardware
failed.
780-232 D 849 Description: The adapter card hardware
failed.
227
780-240 D 780 Description: The adapter card hardware
failed.
780-250 D 185 Description: An error was found on the
adapter.
780
780-260 D 780 Description: The adapter card hardware
failed.
780-270 D 780 Description: The adapter card hardware
failed.
780-280 D 780 Description: The adapter card hardware
failed.
780-290 D 780 Description: The adapter card hardware
failed.
780-300 G 780 Description: An adapter error was found
during error log analysis.
780-310 G 780 Description: An adapter error was found
during error log analysis.
185
780-320 G 780 Description: An adapter error was found
during error log analysis.
227
780-330 G 780 Description: Error log analysis indicates
a hardware problem.
227
780-400 D 780 Description: A software error was caused
by a hardware failure.
227
780-700 D 780 Description: The adapter failed to
configure.
227
software
780-720 D 780 Description: Cable wrap test failed.
780-721 D 780 Description: Port wrap test failed.
780-722 D 780 Description: Cable wrap test failed.
781-101 D 781 Description: ROS POST adapter software
initialization error.
227
781-102 D 781 Description: Extended DRAM SIP test
failed.
781-103 D 781 Description: ROS checksum test failed.
781-104 D 781 Adapter download diagnostics failed
227
781-105 D 781 Description: Memory size test failed.
227
781-106 D 781 Description: Interface ID test failed.
227
781-107 D 781 Description: EIB ID test failed.
227
781-108 D 781 Description: ROS version test failed.
227
781-109 D 781 Description: DUSCC register test failed.
781-111 D 781 Description: DMA register test failed.
781-112 D 781 Description: X.21 PAL test failed.
781-113 D 781 Description: External wrap test failed.
781-114 D 781 Description: Twin tail logic test failed.
227
781-116 D 254 Description: The RS-232 cable wrap test
failed.
781-117 D 253 Description: The RS-422A cable wrap test
failed.
781-118 D 257 Description: The V.35 cable wrap test
failed.
781-119 D 260 Description: The X.21 cable wrap test
failed.
781-120 D 781 Description: The adapter was not detected
or could not be configured. test failed.
227
software
781-121 D 781 Description: The 4-port jumper cable
assembly wrap test failed.
227
software
781-200 G 781 Description: The error log analysis
indicates the adapter failed.
781-221 G 781 Description: The error log analysis
indicates the adapter hardware failed.
227
781-231 D 855 Description: No interface card detected.
227
781-501 D B77 Description: The power-on self-test (POST)
failed.
B69
227
781-502 D B77 Description: The memory module failed.
781-503 D 781 Description: Adapter hardware failure.
227
781-504 D B69 Description: Adapter hardware failure.
781-505 D B71 Description: Adapter hardware failure.
B69
781-506 D B72 Description: Adapter hardware failure.
B69
781-507 D B73 Description: Adapter hardware failure.
B69
781-508 D B74 Description: Adapter hardware failure.
B69
781-516 D B77 Description: Adapter Test Failure
B69
781-517 D B69 Description: Adapter Test Failure
B77
781-720 D 258 4-port multiprotocol cable
781
783-110 D 783 Description: The Reserve command failed.
783-120 D 783 Description: The Inquiry command failed.
783-130 D 783 Description: The Load command failed.
media
783-135 D 783 Description: The Unload command failed.
media
783-140 D 783 Description: The Mode Select command
failed.
783-150 D 783 Description: The Test Unit Ready command
failed.
media
783-160 D 783 Description: The Send Diagnostic command
failed.
media
783-169 D 783 Description: The send diagnostic command
failed.
media
783-170 D 783 Description: The Read, Write and Compare
test failed.
B88
media
783-180 D 783 Description: The Load command failed.
media
783-185 D 783 Description: The Unload command failed.
media
783-190 D 783 Description: The Mode Select command
failed.
783-200 D 783 Description: The Test Unit Ready command
failed.
media
783-210 D 783 Description: The device configuration
failed.
B88
783-220 D 783 Description: The Release command failed.
783-230 D 783 Description: The Request Sense command
failed.
783-240 D 783 Description: The Openx command failed.
783-300 D 783 Description: The device configuration
failed.
software
783-310 D B88 Description: SCSI adapter configuration
failed.
783
software
783-320 G 783 Description: Error log analysis indicates
a failure.
media
783-411 D 783 Description: A reservation conflict
to occurred.
783-423 B88
software
783-511 D 783 Description: The drive returned bad or
to non-extended sense data.
783-523 B88
783-611 D 783 Description: An adapter or bus I/O error
to occurred.
783-623 B88
software
783-711 D 783 Description: A device timeout error
to occurred.
783-723 B88
software
784-102 D 784 Description: An unrecoverable media error.
784-104 D 784 Description: The motor failed to restart.
784-105 D 784 Description: The drive did not become
ready.
784-106 D 784 Description: The electronics card test
failed.
784-108 D 784 Description: The bus test failed.
784-110 D 784 Description: The media format is
corrupted.
784-112 D 784 Description: The diagnostic test failed.
784-114 D 784 Description: An unrecoverable hardware
error.
784-116 D Description: A protocol error.
Action: Check the levels of the device,
adapter, diagnostic software, and
application software to be sure they are
all compatible. If you do not find a
problem, call your support person.
784-117 D 784 Description: A write protect error
occurred.
784-118 D 784 Description: A SCSI command time-out.
B88
784-120 D 784 Description: A SCSI busy or command error.
784-122 D 784 Description: A SCSI reservation conflict
error.
784-124 D 784 Description: A SCSI check condition error.
784-126 D 784 Description: A software error was caused
by a hardware failure.
B88
784-128 G 784 Description: The error log analysis
indicates a hardware failure.
784-129 G D50 Description: Error log analysis indicates
a SCSI bus problem.
784
B88
software
784-130 G 784 Description: Error log analysis indicates
a problem reported by the disk drive's self
monitoring function.
784-132 D 784 Description: A disk drive hardware error
occurred.
784-134 D B88 Description: The adapter failed to
configure.
software
784-135 D 784 Description: The device failed to
B88 configure.
software
784-136 D 784 Description: The certify operation failed.
784-137 D 784 Description: Unit attention condition has
occurred on the Send Diagnostic command.
B88
D50
785-111 D 785 Could not do the test because the device
driver detected a hardware error.
227
785-114 D 785 The register verification test failed.
785-121 D 785 Could not do the test because the device
driver detected a hardware error.
227
785-122 D 785 The data wrap communication test failed.
227
785-123 D 785 The modem control line test failed.
227
785-124 D 785 The memory test failed.
785-151 D 785 Could not do the test because the device
driver detected a hardware error.
D57
785-152 D 785 The data wrap communication test failed.
D57
785-153 D 785 The modem control line test failed.
D57
785-171 D 259 Could not do the test because the device
driver detected a hardware error.
785-172 D 259 The data wrap communication test failed.
785-173 D 259 The modem control line test failed.
785-181 D 261 Could not do the test because the device
driver detected a hardware error.
785-182 D 261 The data wrap communication test failed.
785-183 D 261 The modem control line test failed.
785-251 D 785 Could not perform because the device
driver detected a hardware error.
D57
785-252 D 785 The data wrap communication test failed.
D57
785-253 D 785 The modem control line test failed.
D57
785-271 D 785 Could not perform because the device
driver detected a hardware error.
D57
785-272 D 785 The data wrap communication test failed.
D57
785-273 D 785 The modem control line test failed.
D57
785-281 D 785 Could not perform because the device
driver detected a hardware error.
D57
785-282 D 785 The data wrap communication test failed.
D57
785-283 D 785 The modem control line test failed.
D57
785-481 D D57 Could not do the test because the device
driver detected a hardware error.
785-482 D D57 The data wrap communication test failed.
785-483 D D57 The modem control line test failed.
785-901 D software Description: An unexpected error occurred
that can be attributed to software or
to 785 hardware.
785-920 Action: Run diagnostics from a source other
than from the disk or a network. If the
same error occurs or if the original SRN
was not obtained from disk or a network
based diagnostics, use Chapter 12. "MAP
0210: General Problem Resolution" with a
FFC of 785; otherwise, suspect a software
problem.
785-921 D 785 Description: The adapter failed to
configure
software
785-922 D software Description: An unexpected error occurred
that can be attributed to software or
to 785 hardware.
785-924 Action: Run diagnostics from a source other
than from the disk or a network. If the
same error occurs or if the original SRN
was not obtained from disk or a network
based diagnostics, use Chapter 12. "MAP
0210: General Problem Resolution" with a
FFC of 785; otherwise, suspect a software
problem.
785-925 D 785 Description: The adapter failed to
configure
software
785-926 D software Description: An unexpected error occurred
that can be attributed to software or
to 785 hardware.
785-943 Action: Run diagnostics from a source other
than from the disk or a network. If the
same error occurs or if the original SRN
was not obtained from disk or a network
based diagnostics, use Chapter 12. "MAP
0210: General Problem Resolution" with a
FFC of 785; otherwise, suspect a software
problem.
786-200 D 786 Description: Initiation failed
D96 Note: You must determine which of the first
two FFCs is installed in the system unit.
227
786-210 D 786 Description: The adapter test failed
227
786-211 D D96 Description: The adapter test failed
227
786-220 D 786 Description: The display test failed
Cable
Monitor
786-221 D D96 Description: The display test failed
Cable
Monitor
786-710 D 786 Description: The ELA indicates HW failure
227
786-711 D D96 The ELA indicates HW failure
227
787-100 D 787 GXT500P Graphics Adapter
787-101 D 787 Description: GXT500P Graphics Adapter
227
787-1AA D 787 Description: GXT500P Graphics Adapter
RGB Cable
Display
787-1xx D 787 Description: GXT500P Graphics Adapter
787-200 D D95 Description: GXT550P Graphics Adapter
787-201 D D95 Description: GXT550P Graphics Adapter
227
787-2AA D D95 Description: GXT550P Graphics Adapter
RGB Cable
Display
787-2xx D D95 Description: GXT550P Graphics Adapter
788-001 D 788 Description: Adapter Error
227
788-002 D software Description: System Error
788
788-003 D software Description: System Error
788
788-004 D 788 Description: System Error
software
789-101 D 789 Description: Failed to release the device.
789-102 D 789 Description: Failed to reserve the device.
789-103 D 789 Description: The device motor failed to
start.
789-104 D 789 Description: Failed to make the device
ready.
789-105 D 789 Description: Failed to get the inquiry
data.
789-106 D 789 Description: The Prevent Media Removal
command failed.
789-107 D 789 Description: The Allow Media Removal
command failed.
789-200 D 789 Description: The optical disk failed to
load.
Optical Disk Action: Change the media. Run diagnostics
on the changed media in System Verification
mode. If the error reoccurs use Chapter 12.
"MAP 0210: General Problem Resolution";
otherwise, replace the media.
789-201 D 789 Description: Failed to unload the optical
disk.
Optical Disk Action: Change the media. Run diagnostics
on the changed media in System Verification
mode. If the errors reoccur use Chapter 12.
"MAP 0210: General Problem Resolution";
otherwise, replace the media.
789-202 D 789 Description: The diagnostic test failed.
Action: Change the media. Run diagnostics
Optical Disk on the changed media in System Verification
mode. If errors do not reoccur, replace the
media; otherwise, run the drive cleaning
procedures if applicable and rerun the
diagnostics. If errors reoccur, or the
drive does not support the cleaning
procedures use Chapter 12. "MAP 0210:
General Problem Resolution".
789-204 D 789 Description: The device failed to
configure.
B88
789-205 D 789 Description: The Test Unit Ready command
failed.
Optical Disk Action: Change the media. Run diagnostics
on the changed media in System Verification
mode. If the error reoccurs, use Chapter
12. "MAP 0210: General Problem Resolution";
otherwise, replace the media.
789-206 D 789 Description: The random write, read and
compare test failed.
Optical Disk Action: Change the media. Run diagnostics
on the changed media in System Verification
mode. If the errors do not reoccur, replace
the media; otherwise, run the drive
cleaning procedures if applicable, and
rerun diagnostics. If the errors reoccur,
or the drive does not support cleaning
procedures, use Chapter 12. "MAP 0210:
General Problem Resolution".
789-207 D 789 Description: A hardware error occurred.
Action: Change the media. Run diagnostics
Optical Disk on the changed media in System Verification
mode. If the errors do not reoccur, replace
the media; otherwise, run the drive
cleaning procedures if applicable, and
rerun diagnostics. If the errors reoccur,
or the drive does not support cleaning
procedures, use Chapter 12. "MAP 0210:
General Problem Resolution".
789-208 D 789 Description: The Mode Sense command
failed.
Optical Disk Action: Change the media. Run diagnostics
on the changed media in System Verification
mode. If the errors do not reoccur, replace
the media; otherwise, run the drive
cleaning procedures if applicable, and
rerun diagnostics. If the errors reoccur,
or the drive does not support cleaning
procedures, use Chapter 12. "MAP 0210:
General Problem Resolution".
789-209 D 789 Description: The Mode Select command
failed.
Optical Disk Action: Change the media. Run diagnostics
on the changed media in System Verification
mode. If the errors do not reoccur, replace
the media; otherwise, run the drive
cleaning procedures if applicable, and
rerun diagnostics. If the errors reoccur,
or the drive does not support cleaning
procedures, use Chapter 12. "MAP 0210:
General Problem Resolution".
789-300 D 789 Description: A SCSI reservation conflict
has occurred.
B88
software
789-400 D 789 Description: A SCSI command time out has
occurred.
B88
Cables
software
789-401 D Optical Disk Description: An unknown error has
occurred.
D50
B88
software
789-402 D Optical Disk Description: Unit attention condition has
occurred.
D50
B88
software
789-600 G Optical Disk Description: ELA indicates that the spare
sectors on the disk are exhausted.
Action: Backup the media and replace it.
Note: Use the time when the error occurred
and the "Spare Sector Availability" service
aid to identify the disk that has the
error.
789-700 G 789 Description: The ELA indicates an
equipment error.
Optical Disk Action: Run diagnostics in System
Verification mode to isolate the problem.
If errors are reported, use Chapter 12.
"MAP 0210: General Problem Resolution";
otherwise, the error is due to faulty
media. Backup the media and then replace
it.
Note: Use the time when the error occurred
to identify the faulty media.
789-701 G Optical Disk Description: ELA indicates an
irrecoverable data error.
789 Action: Run diagnostics in System
Verification mode to isolate the problem.
If errors are reported, use Chapter 12.
"MAP 0210: General Problem Resolution";
otherwise, the error is due to faulty
media. Backup the media and then replace
it.
Note: Use the time when the error occurred
to identify the faulty media.
789-702 G 789 Description: ELA indicates that the
adapter detected an error.
B88 Action: Use the 7209 Installation and
Service Guide. If the unit checks out to be
Cables good, use Chapter 12. "MAP 0210: General
Problem Resolution".
790-101 D 790 Description: Configuration Register Test
failure
790-102 D 790 Description: I/O test failure
790-103 D 790 Description: Adapter initialization test
failure
790-104 D 790 Description: Internal wrap test failure
790-105 D 790 Description: Internal wrap test failure
790-106 D 790 Description: External wrap (10Mbps) test
failure
790-107 D 790 Description: Internal wrap test failure
790-108 D 790 Description: External wrap (100Mbps) test
failure
790-109 D 790 Description: External wrap (10Mbps) test
failure
790-121 D 790 Description: Configuration register test
failure
790-122 D 790 Description: I/O register test failure
790-124 D 790 Description: Internal loopback test
failure
790-125 D 790 Description: Internal loopback test
failure
790-126 D 790 Description: External loopback test
failure
790-150 D B08 Description: 10Base-T transceiver test
failure
790-151 D B09 Description: 10Base-2 transceiver test
failure
790-223 D 790 Description: Device configuration failure
software
790-224 D B08 Description: 10 Base-T transceiver test
failure
790
790-225 D B09 Description: 10 Base-2 transceiver test
failure
790
790-250 D B08 Description: 10 Base-T transceiver test
failure
790
790-251 D B09 Description: 10 Base-2 transceiver test
failure
790
790-701 G 790 Description: Error Log Analysis indicates
that the adapter is not responding to
initialization commands.
790-702 G 790 Description: Error Log Analysis indicates
that the device driver has detected a PIO
error which it was unable to correct.
790-703 G 790 Description: Error Log Analysis indicates
that the adapter has been shutdown due to
an unrecoverable error.
790-704 G 790 Description: Error Log Analysis indicates
a problem with EEPROM on the adapter.
790-720 G 790 Description: Error log analysis indicates
a hardware problem
software
791-098 Description: The disk drive indicates an
J 791 error.
B88
791-099 Description: The disk drive not found.
J 791
B88
791-102 Description: An unrecoverable media error
D 791 occurred.
791-104 Description: The motor failed to restart.
D 791
791-105 Description: The drive did not become
D 791 ready.
791-106 Description: The electronics card test
D 791 failed.
791-108 Description: The bus test failed.
D 791
791-110 Description: The media format is
D 791 corrupted.
791-112 Description: The diagnostic test failed.
D 791
791-114 Description: An unrecoverable hardware
D 791 error.
791-116 Description: A protocol error.
D Action: Check the levels of the device,
adapter, diagnostic software, and
application software to be sure they are
all compatible. If you do not find a
problem, call your support person.
791-117 Description: A write protect error
D 791 occurred.
791-118 Description: A SCSI command time-out
D 791 occurred.
B88
791-120 Description: A SCSI busy or command
D 791 error.
791-122 Description: A SCSI reservation conflict
D 791 error.
791-124 Description: A SCSI check condition error
D 791 occurred.
791-126 Description: A software error was caused
D 791 by a hardware failure.
B88
791-128 Description: The error log analysis
G 791 indicates a hardware failure.
791-129 G D50 Description: Error log analysis indicates
a SCSI bus problem.
791
B88
software
791-130 G 791 Description: Error log analysis indicates
a problem reported by the disk drive's self
monitoring function.
791-132 D 791 Description: A disk drive hardware error
occurred.
791-134 D B88 Description: The adapter failed to
configure.
software
791-135 D 791 Description: The device failed to
configure.
B88
software
791-136 D 791 Description: The certify operation failed.
791-137 D 791 Description: Unit attention condition has
occurred on the Send Diagnostic command.
B88
D50
792-098 Description: The disk drive indicates an
J 792 error.
B88
792-099 Description: The disk drive not found.
J 792
B88
792-102 Description: An unrecoverable media error
D 792 occurred.
792-104 Description: The motor failed to restart.
D 792
792-105 Description: The drive did not become
D 792 ready.
792-106 Description: The electronics card test
D 792 failed.
792-108 Description: The bus test failed.
D 792
792-110 Description: The media format is
D 792 corrupted.
792-112 Description: The diagnostic test failed.
D 792
792-114 Description: An unrecoverable hardware
D 792 error.
792-116 Description: A protocol error.
D Action: Check the levels of the device,
adapter, diagnostic software, and
application software to be sure they are
all compatible. If you do not find a
problem, call your support person.
792-117 Description: A write protect error
D 792 occurred.
792-118 Description: A SCSI command time-out
D 792 occurred.
B88
792-120 Description: A SCSI busy or command
D 792 error.
792-122 Description: A SCSI reservation conflict
D 792 error.
792-124 Description: A SCSI check condition error
D 792 occurred.
792-126 Description: A software error was caused
D 792 by a hardware failure.
B88
792-128 Description: The error log analysis
G 792 indicates a hardware failure.
792-129 G D50 Description: Error log analysis indicates
a SCSI bus problem.
792
B88
software
792-130 G 792 Description: Error log analysis indicates
a problem reported by the disk drive's self
monitoring function.
792-132 Description: A disk drive hardware error
D 792 occurred.
792-134 Description: The adapter failed to
D B88 configure.
software
792-135 D 792 Description: The device failed to
B88 configure.
software
792-136 D 792 Description: The certify operation failed.
792-137 D 792 Description: Unit attention condition has
occurred on the Send Diagnostic command.
B88
D50
793-098 J 793 Description: The disk drive indicates an
error.
B88
793-099 J 793 Description: The disk drive not found.
B88
793-102 D 793 Description: An unrecoverable media error
occurred.
793-104 Description: The motor failed to restart.
D 793
793-105 Description: The drive did not become
D 793 ready.
793-106 Description: The electronics card test
D 793 failed.
793-108 Description: The bus test failed.
D 793
793-110 Description: The media format is
D 793 corrupted.
793-112 Description: The diagnostic test failed.
D 793
793-114 Description: An unrecoverable hardware
D 793 error.
793-116 Description: A protocol error.
D Action: Check the levels of the device,
adapter, diagnostic software, and
application software to be sure they are
all compatible. If you do not find a
problem, call your support person.
793-117 Description: A write protect error
D 793 occurred.
793-118 Description: A SCSI command time-out
D 793 occurred.
B88
793-120 Description: A SCSI busy or command
D 793 error.
793-122 Description: A SCSI reservation conflict
D 793 error.
793-124 Description: A SCSI check condition error
D 793 occurred.
793-126 Description: A software error was caused
D 793 by a hardware failure.
B88
793-128 G 793 Description: The error log analysis
indicates a hardware failure.
793-129 G D50 Description: Error log analysis indicates
a SCSI bus problem.
793
B88
software
793-130 G 793 Description: Error log analysis indicates
a problem reported by the disk drive's self
monitoring function.
793-132 Description: A disk drive hardware error
D 793 occurred.
793-134 Description: The adapter failed to
D B88 configure.
software
793-135 D 793 Description: The device failed to
B88 configure.
software
793-136 Description: The certify operation
D 793 failed.
793-137 D 793 Description: Unit attention condition has
occurred on the Send Diagnostic command.
B88
D50
795-201 D 795 Description: Config register test failure
795-202 D 795 Description: PROM check test failure
795-203 D 795 Description: Timer and IRQ test failure
795-204 D 795 Description: Adapter RAM check failure
795-205 D 795 Description: ASIC test failure
795-206 D 795 Description: High memory (ISA) test
failure
795-207 D 795 Description: RAM check via DMA test
failure
795-208 D 795 Description: FORMAC register test failure
795-209 D 795 Description: PLC1 test failure
221
795-210 D 795 Description: PLC2 test failure
795-211 D 795 Description: FORMAC Ring_Op test failure
795-212 D 795 Description: Send long frame test failure
795-213 D 795 Description: Restricted Token Monitor test
failure
795-214 D 795 Description: Receive queue handling test
failure
795-215 D 795 Description: FORMAC loopback test failure
795-216 D 795 Description: FORMAC loopback with master
access test failure
795-217 D 795 Description: DMA measurement test failure
795-218 D 795 Description: Special test failure
795-219 D 795 Description: Bypass test failure
795-301 D 795 Description: PLC1 FDDI external wrap
failure
795-302 D 795 Description: PLC2 FDDI external wrap
failure
795-303 D 795 Description: Send long frame FDDI external
wrap failure
795-304 D 795 Description: FORMAC loopback external wrap
failure
795-700 D 795 Description: Error log analysis indicates
hardware failure
799-101 D 2C3 Description: External wrap test failed on
port 0
799
799-102 D 2C3 Description: External wrap test failed on
port 1
799
799-201 D 799 Description: Internal adapter test failed
227
799-202 D 799 Description: External wrap test failed on
port 0
227
799-203 D 799 Description: External wrap test failed on
port 1
227
799-204 D 2C3 Description: External wrap test failed on
port 0
799
799-205 D 2C3 Description: External wrap test failed on
port 1
799
799-206 D 2C3 Description: External wrap test failed on
port 0
799
software
799-207 D 2C3 Description: External wrap test failed on
port 1
799
software
799-301 D 799 Description: Internal adapter test failed
227
software
799-302 D 799 Description: External wrap test failed on
port 0
227
software
799-303 D 799 Description: External wrap test failed on
port 1
227
software
799-304 D 2C3 Description: External wrap test failed on
port 0
799
software
799-305 D 2C3 Description: External wrap test failed on
port 1
799
software
799-700 D 799 Description: Error log analysis indicates
a hardware problem
software
7C1-101 D 7C1 Description: Audio Subsystem failed
software
7C1-102 D 7C1 Description: CS4232 Failed
7C1-103 D 7C1 Description: Clock control failed
7C1-107 D 7C1 Description: SoundBlaster interface failed
7C1-108 D 7C1 Description: Loop back failed
7C1-109 D 7C1 Description: CODEC ID invalid
7C1-117 D D97 Description: Internal speaker failed
801-101 C Description: The diagnostics did not
detect an installed resource.
to Action: Ensure supplemental diskettes have
been read, if applicable, then use Chapter
801-102 18. "MAP 0290: Missing Resource Problem
Resolution".
802-787 C 787 Description: The diagnostics did not
detect an installed resource.
D95
802-78C C Description: A system bus problem exists.
Action: Use Chapter 11. "MAP 0080 System
Bus Problem Isolation".
802-xxx C xxx Description: The diagnostics did not
detect an installed resource.
Note: To obtain the FFC substitute the last
three digits of the SRN for xxx. (The
substituted xxx is the FFC.)
803-xxx D Use the xxx Description: An error occurred while
running the diagnostics.
See note number Action: Run nondisk-based diagnostics where
possible. If this SRN was generated from
n Action the nondisk-based diagnostic package, or it
is not possible to use the nondisk-based
column.) package, go to Chapter 15. "MAP 0250:
Unexpected System Halts During
Diagnostics". If the problem occurs only
from disk-or server-based diagnostics,
suspect a software problem.
Notes:
1. If your 803-xxx SRN is listed in
this section, use the procedure
for that SRN instead of this one.
2. If the xxx FFC is not listed in
the FFC list, Use MAP 1540 to
determine the failing FRU.
804-111 D 804 Description: Unable to reserve device.
B88
804-112 D 804 Description: Unable to do configuration.
B88
804-113 D 804 Description: Unable to open the device
driver.
B88
804-121 D 804 Description: The CD-ROM drive indicates an
error.
804-122 D 804 Description: The CD-ROM drive indicates an
error.
804-123 D 804 Description: The CD-ROM drive indicates an
error.
804-125 D 804 Description: The CD-ROM drive indicates an
error.
B88
804-126 D 804 Description: The CD-ROM drive indicates an
error.
804-127 D 804 Description: The CD-ROM drive indicates an
error.
804-128 D 804 Description: The CD-ROM drive indicates an
error.
804-129 D 804 Description: The CD-ROM drive indicates an
error.
804-150 D Media Description: A media error was detected.
804
804-151 D 804 Description: A command timeout was
detected.
B88
804-152 D 804 Description: A command reservation
conflict was detected.
804-162 D 804 Description: The CD-ROM drive indicates an
error.
804-171 D 804 Description: Unable to reserve device.
804-172 D 804 Description: Unable to do configuration.
804-173 D 804 Description: Unable to open device driver.
804-175 D 804 Description: The CD-ROM drive indicates an
error.
804-198 D 804 Description: Undefined error detected.
B88
804-199 D 804 Description: Undefined error detected.
804-211 D 804 Description: The LED test failed.
804-281 D 804 Description: No tone during audio test.
804-301 G 804 Description: Errors found during ELA.
804-302 G 804 Description: Errors found during ELA.
B88
804-xxx H Use the Description: An unexpected halt occurred
while running the diagnostics.
xxx
Note: If your 804-xxx SRN is listed in this
number section, use the procedure for that SRN
instead of this one.
Action: Use Chapter 15. "MAP 0250:
Unexpected System Halts During
Diagnostics".
805-110 G D67 Description: Error log analysis indicates
a machine check due to uncorrectable memory
error.
Action: Use Chapter 14. "MAP 0240: Memory
Problem Resolution".
805-111 G D83 Description: Error log analysis indicates
a machine check due to uncorrectable memory
error.
Action: Use Chapter 14. "MAP 0240: Memory
Problem Resolution".
805-120 G D68 Description: Error log analysis indicates
a machine check due to uncorrectable memory
error.
Action: Use Chapter 14. "MAP 0240: Memory
Problem Resolution".
805-121 G D84 Description: Error log analysis indicates
a machine check due to uncorrectable memory
error.
Action: Use Chapter 14. "MAP 0240: Memory
Problem Resolution".
805-130 G D69 Description: Error log analysis indicates
a machine check due to uncorrectable memory
error.
Action: Use Chapter 14. "MAP 0240: Memory
Problem Resolution".
805-131 G D85 Description: Error log analysis indicates
a machine check due to uncorrectable memory
error.
Action: Use Chapter 14. "MAP 0240: Memory
Problem Resolution".
805-140 G D70 Description: Error log analysis indicates
a machine check due to uncorrectable memory
error.
Action: Use Chapter 14. "MAP 0240: Memory
Problem Resolution".
805-141 G D86 Description: Error log analysis indicates
a machine check due to uncorrectable memory
error.
Action: Use Chapter 14. "MAP 0240: Memory
Problem Resolution".
805-150 G E11 Description: Error log analysis indicates
a machine check due to uncorrectable memory
error.
Action: Use Chapter 14. "MAP 0240: Memory
Problem Resolution".
805-151 G E14 Description: Error log analysis indicates
a machine check due to uncorrectable memory
error.
Action: Use Chapter 14. "MAP 0240: Memory
Problem Resolution".
805-210 G D71 Description: Error log analysis indicates
a machine check due to uncorrectable memory
error.
Action: Use Chapter 14. "MAP 0240: Memory
Problem Resolution".
805-211 G D87 Description: Error log analysis indicates
a machine check due to uncorrectable memory
error.
Action: Use Chapter 14. "MAP 0240: Memory
Problem Resolution".
805-220 G D72 Description: Error log analysis indicates
a machine check due to uncorrectable memory
error.
Action: Use Chapter 14. "MAP 0240: Memory
Problem Resolution".
805-221 G D88 Description: Error log analysis indicates
a machine check due to uncorrectable memory
error.
Action: Use Chapter 14. "MAP 0240: Memory
Problem Resolution".
805-230 G D73 Description: Error log analysis indicates
a machine check due to uncorrectable memory
error.
Action: Use Chapter 14. "MAP 0240: Memory
Problem Resolution".
805-231 G D89 Description: Error log analysis indicates
a machine check due to uncorrectable memory
error.
Action: Use Chapter 14. "MAP 0240: Memory
Problem Resolution".
805-240 G D74 Description: Error log analysis indicates
a machine check due to uncorrectable memory
error.
Action: Use Chapter 14. "MAP 0240: Memory
Problem Resolution".
805-241 G D90 Description: Error log analysis indicates
a machine check due to uncorrectable memory
error.
Action: Use Chapter 14. "MAP 0240: Memory
Problem Resolution".
805-250 G E12 Description: Error log analysis indicates
a machine check due to uncorrectable memory
error.
Action: Use Chapter 14. "MAP 0240: Memory
Problem Resolution".
805-251 G E15 Description: Error log analysis indicates
a machine check due to uncorrectable memory
error.
Action: Use Chapter 14. "MAP 0240: Memory
Problem Resolution".
805-310 G D75 Description: Error log analysis indicates
a machine check due to uncorrectable memory
error.
Action: Use Chapter 14. "MAP 0240: Memory
Problem Resolution".
805-311 G D91 Description: Error log analysis indicates
a machine check due to uncorrectable memory
error.
Action: Use Chapter 14. "MAP 0240: Memory
Problem Resolution".
805-320 G D76 Description: Error log analysis indicates
a machine check due to uncorrectable memory
error.
Action: Use Chapter 14. "MAP 0240: Memory
Problem Resolution".
805-321 G D92 Description: Error log analysis indicates
a machine check due to uncorrectable memory
error.
Action: Use Chapter 14. "MAP 0240: Memory
Problem Resolution".
805-331 G D93 Description: Error log analysis indicates
a machine check due to uncorrectable memory
error.
Action: Use Chapter 14. "MAP 0240: Memory
Problem Resolution".
805-340 G D78 Description: Error log analysis indicates
a machine check due to uncorrectable memory
error.
Action: Use Chapter 14. "MAP 0240: Memory
Problem Resolution".
805-341 G D94 Description: Error log analysis indicates
a machine check due to uncorrectable memory
error.
Action: Use Chapter 14. "MAP 0240: Memory
Problem Resolution".
805-350 G E13 Description: Error log analysis indicates
a machine check due to uncorrectable memory
error.
Action: Use Chapter 14. "MAP 0240: Memory
Problem Resolution".
805-351 G E16 Description: Error log analysis indicates
a machine check due to uncorrectable memory
error.
Action: Use Chapter 14. "MAP 0240: Memory
Problem Resolution".
805-600 G Description: Error log analysis indicates
a machine check due to uncorrectable memory
error or unsupported memory.
Action: Examine the memory modules and
determine if they are supported types. If
the modules are supported, then replace the
appropriate memory module(s). Use Chapter
14. "MAP 0240: Memory Problem Resolution".
805-601 G 210 Description: Error log analysis indicates
a machine check due to CPU internal cache
error.
805-602 G 214 Description: Error log analysis indicates
a machine check due to CPU address/data bus
D01 parity error.
805-603 G 210 Description: Error log analysis indicates
a machine check due to CPU bus transfer
214 error.
D01
805-604 G 210 Description: Error log analysis indicates
a machine check due to CPU address/data bus
D01 parity error.
805-605 G 210 Description: Error log analysis indicates
a machine check due to CPU bus transfer
error.
805-606 G 214 Description: Error log analysis indicates
a machine check due to memory controller
internal error.
805-607 G 210 Description: Error log analysis indicates
a machine check due to memory address
214 error.
805-608 G 214 Description: Error log analysis indicates
a machine check due to a Flash ROM error.
217
805-609 G D01 Description: Error log analysis indicates
a machine check due to a L2 parity error.
805-610 G Description: Error log analysis indicates
a machine check due to ISA device error,
but the device could not be identified.
Action: Run diagnostics on the ISA devices.
805-611 G Description: Error log analysis indicates
a machine check due to EISA/ISA bus time
out error, but the device could not be
identified.
Action: Run diagnostics on the ISA devices.
If multiple devices fail, use FFC 295.
805-612 G 214 Description: Error log analysis indicates
a machine check due to an Illegal L2
copyback operation.
805-616 G software Description: Error log analysis indicates
a machine check due to software.
805-617 G Description: Error log analysis indicates
a machine check of unknown origin.
Action: If the problem is persistent, use
MAP 1540.
805-618 G Description: Error log analysis indicates
multiple instances of machine check of
unknown origin.
Action: If the problem is persistent, use
MAP 1540.
805-619 G 221 Description: Error log analysis indicates
a machine check due to an unidentified
source on the I/O subsystem. Action: Use
Chapter 12. "MAP 0210: General Problem
Resolution".
805-621 G 292 Description: Error log analysis indicates
a machine check due to Integrated PCI
device does not respond.
805-622 G 293 Description: Error log analysis indicates
a machine check due to Integrated PCI
device does not respond.
805-623 G 294 Description: Error log analysis indicates
a machine check due to Integrated PCI
device does not respond.
805-624 G 295 Description: Error log analysis indicates
a machine check due to Integrated PCI
device does not respond.
805-625 G 868 Description: Error log analysis indicates
a machine check due to Integrated PCI
device does not respond.
805-631 G 292 Description: Error log analysis indicates
a machine check due to Internal error from
PCI device.
805-632 G 293 Description: Error log analysis indicates
a machine check due to Internal error from
PCI device.
805-633 G 294 Description: Error log analysis indicates
a machine check due to Internal error from
PCI device.
805-634 G 295 Description: Error log analysis indicates
a machine check due to Internal error from
PCI device.
805-635 G 868 Description: Error log analysis indicates
a machine check due to Internal error from
PCI device.
805-640 G 2E8 Description: Error log analysis indicates
a machine check due to a system bus error.
214
805-641 G 2E8 Description: Error log analysis indicates
a machine check due to a processor bus
210 error.
805-642 G 2E8 Description: Error log analysis indicates
a machine check due to a directory parity
error.
805-643 G 2E8 Description: Error log analysis indicates
a machine check due to a cache paradox.
805-644 G 2E8 Description: Error log analysis indicates
a machine check due to an internal error.
805-645 G 2E8 Description: Error log analysis indicates
a machine check due to a detected L2 hit
signal.
805-646 G 2E8 Description: Error log analysis indicates
a machine check due to an address/data bus
214 parity error.
805-649 G software Description: Error log analysis indicates
a machine check due to a disabled I/O
address space.
Action: Run Standalone Diagnostics on all
devices. Use any SRN reported. If no other
SRN is reported, suspect a software
problem.
805-801 G 166 Description: Slow fan or defective thermal
sensor.
221 Action: 1) Check spacing around system
enclosure, 2) check for obstructions to
cooling air flow, 3) check that all fans
can rotate freely, and spin with power
applied. If reasons 1, 2 and 3 can be ruled
out, then replace the listed FRUs.
805-802 G 152 Description: Over/Under voltage condition.
210 Action: Check AC line voltage per the Power
MAP in your service guide. If the AC line
voltage is correct replace the listed FRUs.
805-803 G 2E1 Description: System shutdown due to
non-critical over temperature condition.
210 Action: 1) check for obstructions to
cooling air flow, 2) check for accumulated
dust on the CPU and planar. If reasons 1
and 2 can be ruled out, then replace the
listed FRUs.
805-804 G 166 Description: System shutdown due to
critical over temperature condition.
2E1 Action: Check to ensure fans are connected.
If fans are connected, then replace the
152 listed FRUs.
805-805 G 152 Description: System shutdown due to loss
of AC power.
Action: Check the voltage range switch, if
present, on the power supply and ensure
that it is set to match the AC input
voltage. If the range switch is set
correctly or is not present refer to "MAP
1520: Power" in the Service Guide for your
system.
805-807 G 166 Description: System shutdown due to an
inoperative fan.
Action: Check to ensure fans are connected.
If fans are connected replace the listed
FRU.
805-811 D 166 Description: Slow fan or defective thermal
sensor.
Action:
1. Check spacing around system enclosure
2. Check for obstructions to cooling air
flow
3. Check that all fans rotate freely, and
spin when power is applied.
If reasons 1, 2, and 3 can be ruled out,
then replace the listed FRUs.
805-812 D 152 Description: Over/Under voltage condition.
210 Action: Check the AC line voltage per the
Power MAP in your service guide. If the AC
line voltage is correct replace the listed
FRUs.
805-813 D 2E1 Description: System shutdown due to
non-critical over temperature condition.
210 Action:
1. Check for obstructions to cooling air
flow.
2. Check for accumulated dust on the CPU
and planar.
If reasons 1 and 2 can be ruled out, then
replace the listed FRUs.
806-001 D 806 GXT800P Graphics Adapter
thru
806-017
806-018 D 806 GXT800P Graphics Adapter
Monitor/Display Cable
806-100 D 806 Description: GXT800P Graphics Adapter
806-505 D 806 Description: GXT800P Graphics Adapter
GXT800P Base Memory in slot 0, 1, 2, 3, or
298 4
806-515 D 806 Description: GXT800P Graphics Adapter
GXT800P Base and Texture Memory in slot 0,
297 1, 2, 3, or 4
806-619 G 221 Description: Error log analysis indicates
a machine check due to an unidentified
source on the I/O subsystem.
806-700 D 298 GXT800P Base Memory in slot 0
806-701 D 298 GXT800P Base Memory in slot 1
806-702 D 298 GXT800P Base Memory in slot 2
806-703 D 298 GXT800P Base Memory in slot 3
806-704 D 298 GXT800P Base Memory in slot 4
806-710 D 297 GXT800P Base and Texture Memory in slot 0
806-711 D 297 GXT800P Base and Texture Memory in slot 1
806-712 D 297 GXT800P Base and Texture Memory in slot 2
806-713 D 297 GXT800P Base and Texture Memory in slot 3
806-714 D 297 GXT800P Base and Texture Memory in slot 4
806-e00 D 298 GXT800P Base Memory in slot 0
806-e01 D 298 GXT800P Base Memory in slot 1
806-e02 D 298 GXT800P Base Memory in slot 2
806-e03 D 298 GXT800P Base Memory in slot 3
806-e04 D 298 GXT800P Base Memory in slot 4
806-e10 D 297 GXT800P Base and Texture Memory in slot 0
806-e11 D 297 GXT800P Base and Texture Memory in slot 1
806-e12 D 297 GXT800P Base and Texture Memory in slot 2
806-e13 D 297 GXT800P Base and Texture Memory in slot 3
806-e14 D 297 GXT800P Base and Texture Memory in slot 4
807-201 D 199 Description: Device configuration error
891
807-202 D 199 Description: Enclosure failed to open
891
807-203 D 199 Description: Enclosure failed to return
inquiry data
891
807-204 D 152 Description: Redundant power supply or fan
failure
166
807-205 D 152 Description: Redundant power supply or fan
failure
166
814-112 D 814 Description: The NVRAM test failed.
814-113 D 221 Description: The VPD test failed.
814-114 D 814 Description: I/O Card NVRAM test failed.
815-100 D 815 Description: The floating-point processor
test failed.
815-101 D 815 Description: Floating point processor
failed.
815-102 D 815 Description: Floating point processor
failed.
815-200 D 815 Description: Floating point processor
failed.
7C1
816-140 D 165 Description: The four-digit display test
failed.
816
817-123 D 817 Description: The I/O planar time-of-day
clock test failed.
817-124 D 817 Description: Time of day RAM test failed.
817-210 D 817 Description: The time-of-day clock is at
POR.
817-211 D 817 Description: Time of day POR test failed.
169
817-212 D 151 Description: The battery is low.
816
817-213 D 817 Description: The real-time clock is not
running.
817-215 D 817 Description: Time of day clock not running
test failed.
817-217 D 817 Description: Time of day clock not
running.
169
821-111 D 821 Description: Unexpected results from the
test.
B31
821-220 D B10 Description: Keyboard adapter fuse failed.
821
821-221 D 821 Description: The keyboard adapter test
failed.
821-230 D 221 Description: Software error caused by
hardware failure.
821-240 G 821 Description: The error log analysis
indicates hardware failure.
821-241 G 221 Description: The error log analysis
indicates hardware failure.
821-242 G 921 Description: The error log analysis
indicates hardware failure.
821
821-243 G 922 Description: The error log analysis
indicates hardware failure.
821
821-244 G 923 Description: The error log analysis
indicates hardware failure.
821
821-310 D 821 Description: Standard Keyboard Adapter
to failed.
821-331
821-332 D 821 Description: Cannot open device.
software
821-333 D 821 Description: Keyboard/tablet adapter
failed.
to
821-334
821-921 D 921 Description: The keyboard adapter control
logic failed.
821
821-922 D 922 Description: The keyboard adapter control
logic failed.
821
821-923 D 923 Description: The keyboard adapter control
logic failed.
821
823-111 D 823 Description: Standard Mouse adapter
failed.
to 925
823-112
823-113 D B10 Description: The mouse adapter fuse
failed.
823
823-121 D 823 Description: Built-In mouse adapter
problems.
to
823-122
823-130 D 221 Description: Software error caused by
hardware failure.
823-131 D 823 Description: Unable to put mouse adapter
into nonblock mode.
925
823-132 D 823 Description: Built-In mouse adapter
problem.
to
823-133
823-134 D 823 Description: Cannot open device.
software
823-140 G 823 Description: The error log analysis
indicates hardware failure.
823-141 D 823 Description: Unable to place mouse adapter
in block mode.
925
823-142 D 823 Description: Unable to place mouse adapter
in block mode.
823-220 D B10 Description: The mouse adapter fuse
failed.
823
824-220 Description: The tablet adapter fuse
D B10 failed.
824
824-331 Description: An unexpected error occurred.
D 824
227
824-332 Description: The enable/disable device
D 824 test failed.
227 Note:Ensure that the wrap plug was not
attached when the test was run. If the wrap
plug was attached, remove it, and rerun the
test.
824-333 Description: The internal wrap test
D 824 failed.
824-334 Description: The tablet adapter fuse
D B10 failed.
824
824-441 Description: An unexpected error occurred.
D 824
824-442 Description: The wrap test failed.
D 824
824-450 227 Description: Software error caused by
D hardware failure.
824-461 227 Description: The error log analysis
G indicates a hardware failure.
824-511 Description: An unexpected error occurred.
D 824
824-512 Description: Tablet adapter reset test
D 824 failed.
824-522 Description: Adapter fuse failure.
D B10
824
824-523 Description: Device cannot be configured.
D 824
824-524 Description: Cannot open device.
D 824
software
826-111 D 221 Description: Cannot run the test because
the device driver detected a hardware
error.
826-112 D 221 Description: Unable to determine the type
of adapter from the VPD.
826-113 D 826 Description: The VPD verification test
failed.
826-114 D 826 Description: The register verification
test failed.
826-121 D 221 Description: Cannot run the test because
the device driver detected a hardware
error.
826-122 D 221 Description: The data-wrap communications
test failed.
826-123 D 221 Description: The modem control line test
failed.
826-131 D 221 Description: Cannot run the test because
the device driver detected a hardware
error.
826-132 D 221 Description: The data wrap communications
test failed.
826-133 D 221 Description: The modem control line test
failed.
826-161 D 252 Description: Cannot run the test because
the device driver detected a hardware
error.
826-162 D 252 Description: The data wrap communications
test failed.
826-163 D 252 Description: The modem control line test
failed.
826-171 D 259 Description: Cannot run the test because
the device driver detected a hardware
error.
826-172 D 259 Description: The data wrap communications
test failed.
826-173 D 259 Description: The modem control line test
failed.
826-181 D 261 Description: Cannot run the test because
the device driver detected a hardware
error.
826-182 D 261 Description: The data wrap communications
test failed.
826-183 D 261 Description: The modem control line test
failed.
826-271 D 826 Description: Cannot run the test because
the device driver detected a hardware
259 error.
826-272 D 826 Description: The data wrap communications
test failed.
259
826-273 D 826 Description: The modem control line test
failed.
259
826-281 D 826 Description: Cannot run the test because
the device driver detected a hardware
259 error.
826-282 D 826 Description: The data wrap communications
test failed.
259
826-283 D 826 Description: The modem control line test
failed.
259
826-321 D 826 Description: Cannot run the test because
the device driver detected a hardware
error.
826-322 D 826 Description: The data wrap communications
test failed.
826-323 D 826 Description: The modem control line test
failed.
826-331 D 826 Description: Cannot run the test because
the device driver detected a hardware
error.
826-332 D 826 Description: The data wrap communications
test failed.
826-333 D 826 Description: The modem control line test
failed.
826-371 D 826 Description: Cannot run the test because
the device driver detected a hardware
error.
826-372 D 826 Description: The data wrap communications
test failed.
826-373 D 826 Description: The modem control line test
failed.
826-381 D 826 Description: Could not do the test because
the device driver detected a hardware
error.
826-382 D 826 Description: The data wrap communication
test failed.
826-383 D 826 Description: The modem control line test
failed.
826-481 D D56 Description: Could not do the test because
the device driver detected a hardware
error.
826-482 D D56 Description: The data wrap communication
test failed.
826-483 D D56 Description: The modem control line test
failed.
826-581 D 826 Description: Could not do the test because
the device driver detected a hardware
D56 error.
826-582 D 826 Description: The data wrap communication
test failed.
D56
826-583 D 826 Description: The modem control line test
failed.
D56
826-901 D software Description: An unexpected error occurred
that can be attributed to software or
to 826 hardware.
826-920 Action: Run diagnostics from a source other
than from the disk or a network. If the
same error occurs or if the original SRN
was not obtained from disk or a network
based diagnostics, use Chapter 12. "MAP
0210: General Problem Resolution" with a
FFC of 826; otherwise, suspect a software
problem.
826-921 D 826 Description: The adapter failed to
configure
software
826-922 D software Description: An unexpected error occurred
that can be attributed to software or
to 826 hardware.
826-924 Action: Run diagnostics from a source other
than from the disk or a network. If the
same error occurs or if the original SRN
was not obtained from disk or a network
based diagnostics, use Chapter 12. "MAP
0210: General Problem Resolution" with a
FFC of 826; otherwise, suspect a software
problem.
826-925 D 826 Description: The adapter failed to
configure
software
826-926 D software Description: An unexpected error occurred
that can be attributed to software or
to 826 hardware.
826-943 Action: Run diagnostics from a source other
than from the disk or a network. If the
same error occurs or if the original SRN
was not obtained from disk or a network
based diagnostics, use Chapter 12. "MAP
0210: General Problem Resolution" with a
FFC of 826; otherwise, suspect a software
problem.
827-112 D 221 Description: The parallel port data
register write/read test failed.
827-121 D 827 Description: Cannot run the test because
the device driver detected a hardware
error.
827-122 D 827 Description: The parallel port data
register write/read test failed.
827-123 D 827 Description: The parallel port control
register write/read test failed.
827-124 D 827 Description: The parallel port data
register read test failed.
827-125 D 827 Description: The parallel port control
register read test failed.
827-126 D 827 Description: The parallel port control
register read test failed.
827-131 D 827 Description: Cannot run the test because
the device driver detected a hardware
error.
827-132 D 827 Description: The control port register
direction bit (write) test with BIDI
enabled failed.
827-133 D 827 Description: The control port register
direction bit (read) test with BIDI enabled
failed.
827-141 D 827 Description: Cannot run the test because
the device driver detected a hardware
error.
827-142 D 827 Description: The parallel port control
register write/read test with BIDI
enabled failed.
827-151 D 221 Description: Cannot run the test because
the device driver detected a hardware
error.
827-152 D 827 Description: The parallel port status
register read test failed.
827-161 D 827 Description: Cannot run the test because
the device driver detected a hardware
error.
827-162 D 221 Description: The parallel port interrupt
test failed.
827-163 D 221 Description: The parallel port interrupt
test failed.
827-201 D 827 Description: The extend control register
of the parallel port failed a read/write
test.
827-202 D 827 Description: Input/output to the FIFO
(without interrupts) failed.
827-203 D 827 Description: Input/output to the FIFO
(with interrupts) failed.
827-204 D 827 Description: Direct memory access to the
FIFO failed.
828-501 D 828 Description: The diskette adapter test
failed.
82C-102 D 82C Description: Adapter test failed.
82C-104 D 82C Description: Display test failed.
725
830-111 D 830 Description: Could not do the test
because the device driver detected a
227 hardware error.
830-114 D 830 Description: The register verification
test failed.
830-121 D 830 Description: Could not do the test
because the device driver detected a
227 hardware problem.
830-122 D 830 Description: The data wrap communication
test failed.
227
830-123 D 830 Description: The modem control line test
failed.
227
830-124 D 830 Description: The memory test failed.
830-151 D B54 Description: Could not do the test
because the device driver detected a
830 hardware error.
830-152 D B54 Description: The data wrap communication
test failed.
830
830-153 D D54 Description: The modem control line test
failed.
830
830-171 D 259 Description: Could not run the test
because the device driver detected a
hardware error.
830-172 D 259 The data wrap communication test
failed.
830-173 D 259 Description: The modem control line test
failed.
830-181 D 261 Description: Could not do the test
because the device driver detected a
hardware error.
830-182 D 261 Description: The data wrap communication
test failed.
830-183 D 261 Description: Interposer Wrap test
failed.
830-251 D 830 Description: Could not perform because
the device driver detected a hardware
D57 error.
830-252 D 830 Description: The data wrap communication
test failed.
B54
830-253 D 830 Description: The modem control line test
failed.
B54
830-271 D 830 Description: Could not perform because
the device driver detected a hardware
B54 error.
830-272 D 830 Description: The data wrap communication
test failed.
B54
830-273 D 830 Description: The modem control line test
failed
B54
830-281 D 830 Could not perform the test because the
device driver detected a hardware error.
D57
830-282 D 830 Description: The data wrap communication
test failed.
B54
830-283 D 830 Description: The modem control line test
failed.
B54
830-481 D B54 Description: Could not do the test
because the device driver detected a
hardware error.
830-482 D B54 Description: The data wrap communication
test failed.
830-483 D B54 Description: Async Cable Wrap Test
failed.
830-901 D software Description: An unexpected error
occurred that can be attributed to
to 830 software or hardware.
830-920 Action: Run diagnostics from a source
other than from the disk or a network. If
the same error occurs or if the original
SRN was not obtained from disk or a
network based diagnostics, use Chapter
12. "MAP 0210: General Problem
Resolution" with a FFC of 830; otherwise,
suspect a software problem.
830-921 D 830 Description: The adapter failed to
configure
software
830-922 D software Description: An unexpected error
occurred that can be attributed to
to 830 software or hardware.
830-924 Action: Run diagnostics from a source
other than from the disk or a network. If
the same error occurs or if the original
SRN was not obtained from disk or a
network based diagnostics, use Chapter
12. "MAP 0210: General Problem
Resolution" with a FFC of 830; otherwise,
suspect a software problem.
830-925 D 830 Description: The adapter failed to
configure
software
830-926 D software Description: An unexpected error
occurred that can be attributed to
to 830 software or hardware.
830-943 Action: Run diagnostics from a source
other than from the disk or a network. If
the same error occurs or if the original
SRN was not obtained from disk or a
network based diagnostics, use Chapter
12. "MAP 0210: General Problem
Resolution" with a FFC of 830; otherwise,
suspect a software problem.
831-111 D 221 Description: Cannot run the test because
the device driver detected a hardware
error.
831-112 D 221 Description: Unable to determine the
type of adapter from the VPD.
831-113 D 831 Description: The VPD verification test
failed.
831-114 D 831 Description: The register verification
test failed.
831-121 D 221 Description: Cannot run the test because
the device driver detected a hardware
error.
831-122 D 221 Description: The data wrap
communications test failed.
831-123 D 221 Description: The modem control line test
failed.
831-131 D 221 Description: Cannot run the test because
the device driver detected a hardware
error.
831-132 D 221 Description: The data wrap
communications test failed.
831-133 D 221 Description: The modem control line test
failed.
831-161 D 252 Description: Cannot run the test because
the device driver detected a hardware
error.
831-162 D 252 Description: The data wrap
communications test failed.
831-163 D 252 Description: The modem control line test
failed.
831-164 D 221 Description: Cannot run the test because
the device driver detected a hardware
252 error.
831-165 D 221 Description: The data wrap
communications test failed.
252
831-166 D 221 Description: The modem control line test
failed.
252
831-171 D 259 Description: Cannot run the test because
the device driver detected a hardware
error.
831-172 D 259 Description: The data wrap
communications test failed.
831-173 D 259 Description: The modem control line test
failed.
831-181 D 261 Description: Cannot run the test because
the device driver detected a hardware
error.
831-182 D 261 Description: The data wrap
communications test failed.
831-183 D 261 Description: The modem control line test
failed.
831-271 D 831 Description: Cannot run the test because
the device driver detected a hardware
259 error.
831-272 D 831 Description: The data wrap communication
test failed.
259
831-273 D 831 Description: The modem control line test
failed.
259
831-281 D 831 Description: Cannot run the test because
the device driver detected a hardware
259 error.
831-282 D 831 Description: The data wrap
communications test failed.
259
831-283 D 831 Description: The modem control line test
failed.
259
831-321 D 831 Description: Cannot run the test because
the device driver detected a hardware
error.
831-322 D 831 Description: The data wrap
communications test failed.
831-323 D 831 Description: The modem control line test
failed.
831-331 D 831 Description: Cannot run the test because
the device driver detected a hardware
error.
831-332 D 831 Description: The data wrap
communications test failed.
831-333 D 831 Description: The modem control line test
failed.
831-371 D 831 Description: Cannot run the test because
the device driver detected a hardware
error.
831-372 D 831 Description: The data wrap
communications test failed.
831-373 D 831 Description: The modem control line test
failed.
831-381 D 831 Description: Cannot run the test because
the device driver detected a hardware
error.
831-382 D 831 Description: The data wrap
communications test failed.
831-383 D 831 Description: The modem control line test
failed.
831-481 D D56 Description: Could not do the test
because the device driver detected a
hardware error.
831-482 D D56 Description: The data wrap communication
test failed.
831-483 D D56 Description: The modem control line test
failed.
831-581 D 831 Description: Could not do the test
because the device driver detected a
D56 hardware error.
831-582 D 831 Description: The data wrap communication
test failed.
D56
831-583 D 831 Description: The modem control line test
failed.
D56
831-901 D software Description: An unexpected error
occurred that can be attributed to
to 831 software or hardware.
831-920 Action: Run diagnostics from a source
other than from the disk or a network. If
the same error occurs or if the original
SRN was not obtained from disk or a
network based diagnostics, use Chapter
12. "MAP 0210: General Problem
Resolution" with a FFC of 831; otherwise,
suspect a software problem.
831-921 D 831 Description: The adapter failed to
configure
software
831-922 D software Description: An unexpected error
occurred that can be attributed to
to 831 software or hardware.
831-924 Action: Run diagnostics from a source
other than from the disk or a network. If
the same error occurs or if the original
SRN was not obtained from disk or a
network based diagnostics, use Chapter
12. "MAP 0210: General Problem
Resolution" with a FFC of 831; otherwise,
suspect a software problem.
831-925 D 831 Description: The adapter failed to
configure
software
831-926 D software Description: An unexpected error
occurred that can be attributed to
to 831 software or hardware.
831-943 Action: Run diagnostics from a source
other than from the disk or a network. If
the same error occurs or if the original
SRN was not obtained from disk or a
network based diagnostics, use Chapter
12. "MAP 0210: General Problem
Resolution" with a FFC of 831; otherwise,
suspect a software problem.
832-xxx G xxx I/O Device Internal Error
Note: xxx represents the last 3 digits of
the SRN.
833-xxx G xxx Description: PCI device address parity
error, PCI device data parity error, or
296 PCI device abort error. The diagnostics
screen indicates the actual error.
2C9
Note: xxx represents the last 3 digits of
the SRN.
836-101 Description: Cannot run the test
D 836 because the device driver detected a
hardware error.
836-111 Description: Cannot run test because
D 836 the device driver detected a hardware
227 error.
836-112 Description: Unable to determine the
D 836 type of adapter from the VPD.
227
836-113 Description: The VPD verification test
D 836 failed.
836-114 Description: The register verification
D 836 test failed.
836-115 Description: The VPD verification test
D 836 failed.
836-116 Description: The 128-port controller
D B54 line test failed.
836
836-117 D 684 Description: Remote Async Node test
failed.
836-118 Description: Remote async node test
D 837 failed.
836-119 Description: Sync line termination test
F 836 failed.
836-151 Description: Cannot run the test
D 837 because the device driver detected a
hardware error.
836-152 Description: The data wrap
D 837 communications test failed.
836-153 Description: The modem control line
D 837 test failed.
836-154 D 684 Desciption: Cannot run the test because
the device driver detected a hardware
836 error.
836-155 D 684 Description: The data wrap
communications test failed.
836
152
836-161 Description: Cannot run the test
D C22 because the device driver detected a
hardware error.
836-162 Description: The data wrap
D C22 communications test failed.
836-163 Description: The modem control line
D C22 test failed.
836-164 Description: The data wrap
D D06 communication test failed.
836-171 Description: Cannot run the test
D 259 because the device driver detected a
hardware error.
836-172 Description: The data wrap
D 259 communications test failed.
836-173 Description: The modem control line
D 259 test failed.
836-174 D 263 Description: Cannot run the test because
the device driver detected a hardware
error while running the Printer/Terminal
cable wrap test.
836-175 D 263 Description: The data wrap
communications test failed while running
the Printer/Terminal cable wrap test.
836-181 Description: Cannot run the test
D 261 because the device driver detected a
hardware error.
836-182 Description: The data wrap
D 261 communications test failed.
836-183 Description: The modem control line
D 261 test failed.
836-251 Description: Cannot run the test
D 836 because the device driver detected a
837 hardware error.
836-252 Description: The data wrap
D 836 communications test failed.
837
836-253 Description: The modem control line
D 836 test failed.
837
836-254 D 836 Description: Cannot run the test because
the device driver detected a hardware
684 error while running the Remote Async Node
wrap test.
836-255 D 836 Description: The data wrap
communications test failed while running
684 the Remote Async Node wrap test.
836-271 Description: Cannot run the test
D 836 because the device driver detected a
837 hardware error.
836-272 Description: The data wrap
D 836 communications test failed.
837
836-273 Description: The modem control line
D 836 test failed.
837
836-274 D 836 Description: Cannot run the test because
the device driver detected a hardware
684 error while running the Printer/Terminal
cable wrap test.
836-275 D 836 Description: The data wrap
communications test failed while running
684 the Printer/Terminal cable wrap test.
836-281 Description: Cannot run the test
D 836 because the device driver detected a
837 hardware error.
836-282 Description: The data wrap
D 836 communication test failed.
837
836-283 Description: The modem control line
D 836 test failed.
837
836-481 Description: Could not do the test
D D56 because the device driver detected a
hardware error.
836-482 Description: The data wrap
D D56 communication test failed.
836-483 Description: The modem control line
D D56 test failed.
836-901 D software Description: An unexpected error
occurred that can be attributed to
to 836 software or hardware.
836-920 Action: Run diagnostics from a source
other than from the disk or a network. If
the same error occurs or if the original
SRN was not obtained from disk or a
network based diagnostics, use Chapter
12. "MAP 0210: General Problem
Resolution" with a FFC of 836; otherwise,
suspect a software problem.
836-921 D 836 Description: The adapter failed to
configure
software
836-922 D software Description: An unexpected error
occurred that can be attributed to
to 836 software or hardware.
836-924 Action: Run diagnostics from a source
other than from the disk or a network. If
the same error occurs or if the original
SRN was not obtained from disk or a
network based diagnostics, use Chapter
12. "MAP 0210: General Problem
Resolution" with a FFC of 836; otherwise,
suspect a software problem.
836-925 D 836 Description: The adapter failed to
configure
software
836-926 D software Description: An unexpected error
occurred that can be attributed to
to 836 software or hardware.
836-943 Action: Run diagnostics from a source
other than from the disk or a network. If
the same error occurs or if the original
SRN was not obtained from disk or a
network based diagnostics, use Chapter
12. "MAP 0210: General Problem
Resolution" with a FFC of 836; otherwise,
suspect a software problem.
840-212 D 840 Description: FIFO empty bit set.
Action: Go to Chapter 7. "MAP 0050: SCSI
221 Problems Isolation Procedure".
840-213 D 840 Description: FIFO empty bit clear.
Action: Go to Chapter 7. "MAP 0050: SCSI
221 Problems Isolation Procedure".
840-214 D 840 Description: FIFO full bit set.
Action: Go to Chapter 7. "MAP 0050: SCSI
221 Problems Isolation Procedure".
840-215 D 840 Description: FIFO full bit clear.
Action: Go to Chapter 7. "MAP 0050: SCSI
221 Problems Isolation Procedure".
840-216 D 840 Description: FIFO data miscompare.
Action: Go to Chapter 7. "MAP 0050: SCSI
221 Problems Isolation Procedure".
840-217 D 840 Description: SCSI FIFO data miscompare.
Action: Go to Chapter 7. "MAP 0050: SCSI
221 Problems Isolation Procedure".
840-218 D 840 Description: SCSI FIFO underflow.
Action: Go to Chapter 7. "MAP 0050: SCSI
221 Problems Isolation Procedure".
840-219 D 840 Description: SCSI parity error.
Action: Go to Chapter 7. "MAP 0050: SCSI
221 Problems Isolation Procedure".
840-220 D 840 Description: SCSI FIFO flags error.
Action: Go to Chapter 7. "MAP 0050: SCSI
221 Problems Isolation Procedure".
840-221 D 840 Description: Miscompare during the
write/read of the configuration register.
221
Action: Go to Chapter 7. "MAP 0050: SCSI
Problems Isolation Procedure".
840-222 D 840 Description: Error during the write/read
of the memory register.
221 Action: Go to Chapter 7. "MAP 0050: SCSI
Problems Isolation Procedure".
840-223 D 840 Description: Miscompare during the
write/read of the memory I/O register.
221 Action: Go to Chapter 7. "MAP 0050: SCSI
Problems Isolation Procedure".
840-224 D 840 Description: Error reading the PCI
configuration register.
221
840-225 D 840 Description: Adapter POST failed.
221
840-230 D D50 Description: Arbitration test failed.
Action: Go to Chapter 7. "MAP 0050: SCSI
840 Problems Isolation Procedure"..
840-231 D D50 Description: Function could not
complete.
840 Action: Go to Chapter 7. "MAP 0050: SCSI
Problems Isolation Procedure".
840-232 D D50 Description: SCSI bus data miscompare.
Action: Go to Chapter 7. "MAP 0050: SCSI
840 Problems Isolation Procedure".
840-240 D 840 Description: No terminal power.
Action: Go to Chapter 7. "MAP 0050: SCSI
221 Problems Isolation Procedure".
840-301 D 840 Description: Configuration open failed
for parent bus.
D50
software
840-700 G 840 Description: Error log analysis
indicates a PCI SCSI adapter failure.
software
840-701 G 840 Description: Error log analysis
indicates a PCI SCSI adapter failure.
software
840-702 G 840 Description: Error log analysis
indicates a PCI SCSI adapter failure.
software
840-703 G 840 Description: Error log analysis
indicates a PCI SCSI adapter failure.
software
840-704 G 840 Description: Error log analysis
indicates a PCI SCSI adapter failure.
software
840-705 G 840 Description: Error log analysis
indicates a PCI SCSI adapter failure.
software
840-800 G 746 Description: Error log analysis
indicates a PCI SCSI adapter PTC failure.
Action: Go to Chapter 7. "MAP 0050: SCSI
Problems Isolation Procedure".
840-802 G 840 Description: Error log analysis
indicates a PCI SCSI bus failure.
Action: Go to Chapter 7. "MAP 0050: SCSI
Problems Isolation Procedure".
844-XXX D 844 Description: A 7135 controller problem
series is indicated.
Action: Use 7135 documentation.
845-XXX D 845 Description: A 7135 DASD drawer problem
is indicated.
series Action: Use 7135 documentation.
846-XXX D 846 Description: A 7135 DASD drawer problem
is indicated.
series Action: Use 7135 documentation.
868-110 D 221 Description: The adapter diagnostic
subcommand test failed.
868-130 D 279 Description: The adapter fuse test
failed.
868-140 D 868 Description: The wrap test failed.
868-150 D 868 Description: The BCR registers
write/read test failed.
868-160 D 868 Description: The POS registers
write/read test failed.
868-170 D 868 Description: The internal/external reset
test failed.
868-180 D 279 Description: The adapter command timed
out.
868
Note: Check the fuse before replacing.
868-190 D 221 Description: A software error was caused
by a hardware failure.
868-191 G 868 Description: Analysis of the error log
indicates a problem with the hardware.
868-192 G 221 Description: Analysis of the error log
indicates a problem with the hardware.
868-193 G 279 Description: Analysis of the error log
indicates a problem with the hardware.
868-194 G 868 Description: Analysis of the error log
indicates a problem with the hardware.
868-200 D 868 Description: ROM CRC error.
868-201 D 868 Description: Adapter RAM error.
868-202 D 868 Description: The control logic failed.
868-203 D 868 Description: The control logic failed.
868-204 D 868 Description: The control logic failed.
868-205 D 868 Description: The control logic failed.
868-206 D 868 Description: Diagnostics completed with
a previous error.
868-211 D 279 Description: The device failed to
configure.
868
software
868-212 D 221 Description: FIFO empty bit set.
Action: Go to Chapter 7. "MAP 0050: SCSI
Problems Isolation Procedure".
868-213 D 221 Description: FIFO empty bit clear.
Action: Go to Chapter 7. "MAP 0050: SCSI
Problems Isolation Procedure".
868-214 D 221 Description: FIFO full bit set.
Action: Go to Chapter 7. "MAP 0050: SCSI
Problems Isolation Procedure".
868-215 D 221 Description: FIFO full bit clear.
Action: Go to Chapter 7. "MAP 0050: SCSI
Problems Isolation Procedure".
868-216 D 221 Description: FIFO data miscompare.
Action: Go to Chapter 7. "MAP 0050: SCSI
Problems Isolation Procedure".
868-217 D 221 Description: SCSI FIFO data miscompare.
Action: Go to Chapter 7. "MAP 0050: SCSI
Problems Isolation Procedure".
868-218 D 221 Description: SCSI FIFO underflow.
Action: Go to Chapter 7. "MAP 0050: SCSI
Problems Isolation Procedure".
868-219 D 221 Description: SCSI parity error.
Action: Go to Chapter 7. "MAP 0050: SCSI
Problems Isolation Procedure".
868-220 D 221 Description: SCSI FIFO flags error.
Action: Go to Chapter 7. "MAP 0050: SCSI
Problems Isolation Procedure".
868-221 D 221 Description: Miscompare during the
write/read of the configuration register.
Action: Go to Chapter 7. "MAP 0050: SCSI
Problems Isolation Procedure".
868-222 D 221 Description: Error during the write/read
of the memory register.
Action: Go to Chapter 7. "MAP 0050: SCSI
Problems Isolation Procedure".
868-223 D 221 Description: Miscompare during the
write/read of the memory I/O register.
Action: Go to Chapter 7. "MAP 0050: SCSI
Problems Isolation Procedure".
868-224 D 221 Description: Error reading the PCI
configuration register.
Action: Use Chapter 12. "MAP 0210:
General Problem Resolution".
868-225 D 221 Description: POST failed.
868-230 D D50 Description: Arbitration test failed.
Action: Go to Chapter 7. "MAP 0050: SCSI
868 Problems Isolation Procedure".
868-231 D D50 Description: Function could not
complete.
868 Action: Go to Chapter 7. "MAP 0050: SCSI
Problems Isolation Procedure".
868-232 D D50 Description: SCSI bus data miscompare.
Action: Go to Chapter 7. "MAP 0050: SCSI
868 Problems Isolation Procedure".
868-240 D 221 Description: No terminal power.
Action: Go to Chapter 7. "MAP 0050: SCSI
Problems Isolation Procedure".
868-301 D 868 Description: Configuration open failed
for parent bus.
D50
software
868-700 G 868 Description: Error log analysis
indicates a PCI SCSI adapter failure.
software
868-701 G 868 Description: Error log analysis
indicates a PCI SCSI adapter failure.
software
868-702 G 868 Description: Error log analysis
indicates a PCI SCSI adapter failure.
software
868-703 G 868 Description: Error log analysis
indicates a PCI SCSI adapter failure.
software
868-704 G 868 Description: Error log analysis
indicates a PCI SCSI adapter failure.
software
868-705 G 868 Description: Error log analysis
indicates a PCI SCSI adapter failure.
software
868-800 G 868 Description: Error log analysis
indicates a PCI SCSI adapter PTC failure.
Action: Go to Chapter 7. "MAP 0050: SCSI
Problems Isolation Procedure".
868-802 G 868 Description: Error log analysis
indicates a PCI SCSI bus failure.
Action: Go to Chapter 7. "MAP 0050: SCSI
Problems Isolation Procedure".
887-101 D 887 Description: POS register test failed.
887-102 D 887 Description: I/O register test failed.
887-103 D 887 Description: Local RAM test failed.
887-104 D 887 Description: Vital Product Data (VPD)
failed.
887-105 D 887 Description: LAN coprocessor internal
tests failed.
887-106 D 887 Description: Internal loopback test
failed.
887-107 D 887 Description: External loopback test
failed.
887-108 D 887 Description: External loopback test
failed.
887-109 D 887 Description: External loopback parity
tests failed.
887-110 D 887 Description: External loopback fairness
test failed.
887-111 D 887 Description: External loopback fairness
and parity tests failed.
887-112 D 887 Description: External loopback (twisted
pair) test failed.
887-113 D 887 Description: External loopback (twisted
pair) parity test failed.
887-114 D 887 Description: Ethernet loopback (twisted
pair) fairness test failed.
887-115 D 887 Description: External loopback (twisted
pair) fairness and parity tests failed.
887-116 D 887 Description: Twisted pair wrap data
failed ).
887-117 D 887 Description: Device configuration fails.
software
887-118 D 887 Description: Device driver indicates a
hardware problem.
887-120 D 887 Description: Device driver indicates a
hardware problem.
887-121 D B08 Description: Ethernet transceiver test
failed.
887-122 B09 Description: Ethernet 10 Base-2
transceiver test failed.
887-123 D 887 Description: Internal loopback test
failed.
887-124 G 887 Description: Error log indicates a
hardware problem.
software
887-125 G 887 Description: Fuse test failed.
887-202 D 887 Description: Vital product data test
failed.
887-203 D 887 Description: Vital product data test
failed.
887-209 D 887 Description: RJ-45 converter test
failed.
887-304 D 887 Description: Coprocessor internal test
failed.
887-305 D 887 Description: Internal loopback test
failed.
887-306 D 887 Description: Internal loopback test
failed.
887-307 D 887 Description: External loopback test
failed.
887-319 D 887 Description: Device driver indicates a
hardware failure.
software
887-400 D 887 Description: Fuse test failed.
887-401 D 887 Description: Circuit breaker for
Ethernet test failed.
887-402 D B09 Description: Ethernet 10 Base-2
transceiver test failed.
887
887-403 D B08 Description: Ethernet 10 Base-T
transceiver test failed.
887
887-404 D C29 Description: RJ-45 converter test
failed.
887
887-405 F Ethernet Description: Rerun diagnostics in
advanced mode for accurate problem
network determination.
887
89c-111 D 89c Description: Unable to reserve device.
B88
89c-112 D 89c Description: Unable to do configuration.
B88
89c-113 D 89c Description: Unable to open the device
driver.
B88
89c-121 D 89c Description: The CD-ROM drive indicates
an error.
89c-122 D 89c Description: The CD-ROM drive indicates
an error.
89c-123 D 89c Description: The CD-ROM drive indicates
an error.
89c-125 D 89c Description: The CD-ROM drive indicates
an error.
B88
89c-126 D 89c Description: The CD-ROM drive indicates
an error.
89c-127 D 89c Description: The CD-ROM drive indicates
an error.
89c-128 D 89c Description: The CD-ROM drive indicates
an error.
89c-129 D 89c Description: The CD-ROM drive indicates
an error.
89c-150 D Media Description: A media error was detected.
89c
89c-151 D 89c Description: A command timeout was
detected.
D88
89c-152 D 89c Description: A command reservation
conflict was detected.
89c-162 D 89c Description: The CD-ROM drive indicates
an error.
89c-171 D 89c Description: Unable to reserve device.
89c-172 D 89c Description: Unable to do configuration.
89c-173 D 89c Description: Unable to open device
driver.
89c-175 D 89c Description: The CD-ROM drive indicates
an error.
89c-198 D 89c Description: Undefined error detected.
B88
89c-199 D 89c Description: Undefined error detected.
89c-211 D 89c Description: The LED test failed.
89c-281 D 89c Description: No tone during audio test.
89c-301 G 89c Description: Errors found during ELA.
89c-302 G 89c Description: Errors found during ELA.
B88