700-102     D        700      Description: 1.1GB single-ended disk drive
   to                        problem.
700-114
700-116     D                 Description: A protocol error.
                             Action: Check the levels of the device,
                             adapter, diagnostic software, and
                             application software to be sure they are
                             all compatible. If you do not find a
                             problem, call your support person.
700-117     D        700      Description: A write protect error
                             occurred.
700-118     D        700      Description: A SCSI command time-out.

                    B88

700-120     D        700      Description: A SCSI error.
   to
700-124
700-126     D        700      Description: A software error was caused
                             by a hardware failure.
                    B88

700-128     G        700      Description: The error log analysis
                             indicates a hardware failure.
700-129     G        D50      Description: Error log analysis indicates
                             a SCSI bus problem.
                    700

                    B88

                  software

700-130     G        700      Description: Error log analysis indicates
                             a problem reported by the disk drive's self
                             monitoring function.
700-132     D        700      Description: A disk drive hardware error
                             occurred.
700-134     D        B88      Description: The adapter failed to
                             configure.
                  software

700-135     D        700      Description: The device failed to
                             configure.
                    B88

                  software

700-136     D        700      Description: The certify operation failed.

700-137     D        700      Description: Unit attention condition has
                             occurred on the Send Diagnostic command.
                    B88

                    D50

701-102     D        701      Description: 1.1GB 16-bit single-ended
   to                        disk drive problem.
701-114
701-116     D                 Description: A protocol error.
                             Action: Check the levels of the device,
                             adapter, diagnostic software, and
                             application software to be sure they are
                             all compatible. If you do not find a
                             problem, call your support person.
701-117     D        701      Description: A write protect error
                             occurred.
701-118     D        701      Description: A SCSI command time-out.

                    B88

701-120     D        701      Description: A SCSI error.
   to
701-124
701-126     D        701      Description: A software error was caused
                             by a hardware failure.
                    B88

701-128     G        701      Description: The error log analysis
                             indicates a hardware failure.
701-129     G        D50      Description: Error log analysis indicates
                             a SCSI bus problem.
                    701

                    B88

                  software

701-130     G        701      Description: Error log analysis indicates
                             a problem reported by the disk drive's self
                             monitoring function.
701-132     D        701      Description: A disk drive hardware error
                             occurred.
701-134     D        B88      Description: The adapter failed to
                             configure.
                  software

701-135     D        701      Description: The device failed to
                             configure.
                    B88

                  software

701-136     D        701      Description: The certify operation failed.

701-137     D        701      Description: Unit attention condition has
                             occurred on the Send Diagnostic command.
                    B88

                    D50

702-102     D        702      Description: 1.1GB 16-bit differential
   to                        disk drive problem.
702-114
702-116     D                 Description: A protocol error.
                             Action: Check the levels of the device,
                             adapter, diagnostic software, and
                             application software to be sure they are
                             all compatible. If you do not find a
                             problem, call your support person.
702-117     D        702      Description: A write protect error
                             occurred.
702-118     D        702      Description: A SCSI command time-out.

                    B88

702-120     D        702      Description: A SCSI error.
   to
702-124
702-126     D        702      Description: A software error was caused
                             by a hardware failure.
                    B88

702-128     G        702      Description: The error log analysis
                             indicates a hardware failure.
702-129     G        D50      Description: Error log analysis indicates
                             a SCSI bus problem.
                    702

                    B88

                  software

702-130     G        702      Description: Error log analysis indicates
                             a problem reported by the disk drive's self
                             monitoring function.
702-132     D        702      Description: A disk drive hardware error
                             occurred.
702-134     D        B88      Description: The adapter failed to
                             configure.
                  software

702-135     D        702      Description: The device failed to
                             configure.
                    B88

                  software

702-136     D        702      Description: The certify operation failed.

702-137     D        702      Description: Unit attention condition has
                             occurred on the Send Diagnostic command.
                    B88

                    D50

703-102     D        703      Description: 2.2GB single-ended disk drive
   to                        problem.
703-114
703-116     D                 Description: A protocol error.
                             Action: Check the levels of the device,
                             adapter, diagnostic software, and
                             application software to be sure they are
                             all compatible. If you do not find a
                             problem, call your support person.
703-117     D        703      Description: A write protect error
                             occurred.
703-118     D        703      Description: A SCSI command time-out.

                    B88

703-120     D        703      Description: A SCSI error.
   to
703-124
703-126     D        703      Description: A software error was caused
                             by a hardware failure.
                    B88

703-128     G        703      Description: The error log analysis
                             indicates a hardware failure.
703-129     G        D50      Description: Error log analysis indicates
                             a SCSI bus problem.
                    703

                    B88

                  software

703-130     G        703      Description: Error log analysis indicates
                             a problem reported by the disk drive's self
                             monitoring function.
703-132     D        703      Description: A disk drive hardware error
                             occurred.
703-134     D        B88      Description: The adapter failed to
                             configure.
                  software

703-135     D        703      Description: The device failed to
                             configure.
                    B88

                  software

703-136     D        703      Description: The certify operation failed.

703-137     D        703      Description: Unit attention condition has
                             occurred on the Send Diagnostic command.
                    B88

                    D50

704-102     D        704      Description: 2.2GB 16-bit single-ended
   to                        disk drive problem.
704-114
704-116     D                 Description: A protocol error.
                             Action: Check the levels of the device,
                             adapter, diagnostic software, and
                             application software to be sure they are
                             all compatible. If you do not find a
                             problem, call your support person.
704-117     D        704      Description: A write protect error
                             occurred.
704-118     D        704      Description: A SCSI command time-out.

                    B88

704-120     D        704      Description: A SCSI error.
   to
704-124
704-126     D        704      Description: A software error was caused
                             by a hardware failure.
                    B88

704-128     G        704      Description: The error log analysis
                             indicates a hardware failure.
704-129     G        D50      Description: Error log analysis indicates
                             a SCSI bus problem.
                    704

                    B88

                  software

704-130     G        704      Description: Error log analysis indicates
                             a problem reported by the disk drive's self
                             monitoring function.
704-132     D        704      Description: A disk drive hardware error
                             occurred.
704-134     D        B88      Description: The adapter failed to
                             configure.
                  software

704-135     D        704      Description: The device failed to
                             configure.
                    B88

                  software

704-136     D        704      Description: The certify operation failed.

704-137     D        704      Description: Unit attention condition has
                             occurred on the Send Diagnostic command.
                    B88

                    D50

705-102     D        705      Description: 2.2GB 16-bit differential
   to                        disk drive problem.
705-114
705-116     D                 Description: A protocol error.
                             Action: Check the levels of the device,
                             adapter, diagnostic software, and
                             application software to be sure they are
                             all compatible. If you do not find a
                             problem, call your support person.
705-117     D        705      Description: A write protect error
                             occurred.
705-118     D        705      Description: A SCSI command time-out.

                    B88

705-120     D        705      Description: A SCSI error.
   to
705-124
705-126     D        705      Description: A software error was caused
                             by a hardware failure.
                    B88

705-128     G        705      Description: The error log analysis
                             indicates a hardware failure.
705-129     G        D50      Description: Error log analysis indicates
                             a SCSI bus problem.
                    705

                    B88

                  software

705-130     G        705      Description: Error log analysis indicates
                             a problem reported by the disk drive's self
                             monitoring function.
705-132     D        705      Description: A disk drive hardware error
                             occurred.
705-134     D        B88      Description: The adapter failed to
                             configure.
                  software

705-135     D        705      Description: The device failed to
                             configure.
                    B88

                  software

705-136     D        705      Description: The certify operation failed.

705-137     D        705      Description: Unit attention condition has
                             occurred on the Send Diagnostic command.
                    B88

                    D50

706-102     D        706      Description: 4.5GB 16-bit single-ended
   to                        disk drive problem
706-114
706-116     D                 Description: A protocol error.
                             Action: Check the levels of the device,
                             adapter, diagnostic software, and
                             application software to be sure they are
                             all compatible. If you do not find a
                             problem, call your support person.
706-117     D        706      Description: A write protect error
                             occurred.
706-118     D        706      Description: A SCSI command time-out.

                    B88

706-120     D        706      Description: A SCSI error.
   to
706-124
706-126     D        706      Description: A software error was caused
                             by a hardware failure.
                    B88

706-128     G        706      Description: The error log analysis
                             indicates a hardware failure.
706-129     G        D50      Description: Error log analysis indicates
                             a SCSI bus problem.
                    706

                    B88

                  software

706-130     G        706      Description: Error log analysis indicates
                             a problem reported by the disk drive's self
                             monitoring function.
706-132     D        706      Description: A disk drive hardware error
                             occurred.
706-134     D        B88      Description: The adapter failed to
                             configure.
                  software

706-135     D        706      Description: The device failed to
                             configure.
                    B88

                  software

706-136     D        706      Description: The certify operation failed.

706-137     D        706      Description: Unit attention condition has
                             occurred on the Send Diagnostic command.
                    B88

                    D50

707-102     D        707      Description: Any of the following may have
   to                        occurred: an unrecoverable media error,
707-114                      motor failed to restart, the drive did not
                             become ready, electronics card test failed,
                             bus test failed, media format failed, or
                             diagnostic test failed.
707-116     D                 Description: A protocol error.
                             Action: Check the levels of the device,
                             adapter, diagnostic software, and
                             application software to be sure they are
                             all compatible. If you do not find a
                             problem, call your support person.
707-117     D        707      Description: A write protect error
                             occurred.
707-118     D        707      Description: A SCSI command time-out.

                    B88

707-120     D        707      Description: A SCSI error.
   to
707-124
707-126     D        707      Description: A software error was caused
                             by a hardware failure.
                    B88

707-128     G        707      Description: The error log analysis
                             indicates a hardware failure.
707-129     G        D50      Description: Error log analysis indicates
                             a SCSI bus problem.
                    707

                    B88

                  software

707-130     G        707      Description: Error log analysis indicates
                             a problem reported by the disk drive's self
                             monitoring function.
707-132     D        707      Description: A disk drive hardware error
                             occurred.
707-134     D        B88      Description: The adapter failed to
                             configure.
                  software

707-135     D        707      Description: The device failed to
                             configure.
                    B88

                  software

707-136     D        707      Description: The certify operation failed.

707-137     D        707      Description: Unit attention condition has
                             occurred on the Send Diagnostic command.
                    B88

                    D50

709-101     D        709      Description: Cannot run the test because
                             the device driver detected a hardware
                             error.
709-111     D        709      Description: Could not do the test because
                             the device driver detected a hardware
                    221      error.

709-112     D        709      Description: Unable to determine the type
                             of adapter from the VPD.
                    221

709-113     D        709      Description: The VPD verification test
                             failed.
709-114     D        709      Description: The register verification
                             test failed.
709-115     D        709      Description: The VPD verification test
                             failed.
709-116     D        D57      Description: The 128-port controller line
                             test failed.
                    709

709-117     D        684      Diagnostics: Remote Async Node test
                             failed.
709-118     D        837      Description: Remote async node test
                             failed.
709-119     F        709      Description: Sync line termination test
                             failed.
709-151     D        837      Description: Could not perform because the
                             device driver detected a hardware error.
709-152     D        837      Description: The data wrap communication
                             test failed.
                    836

709-153     D        837      Description: The modem control line test
                             failed.
709-154     D        684      Diagnostics: Cannot run the test because
                             the
                    709      device driver detected a hardware error.

709-155     D        684      Diagnostics: The data wrap communications
                             test failed.
                    709

                    152

709-161     D        266      Description: Could not perform because the
                             device driver detected a hardware error.
709-162     D        266      Description: The data wrap communication
                             test failed.
709-163     D        266      Description: The modem control line test
                             failed.
709-164     D        D06      Description: The data wrap communication
                             test failed.
709-171     D        259      Description: Could not perform because the
                             device driver detected a hardware error.
709-172     D        259      Description: The data wrap communication
                             test failed.
709-173     D        259      Description: The modem control line test
                             failed.
709-174     D        263      Description: Cannot run the test because
                             the device driver detected a hardware
                             error.
709-175     D        263      Description: The data wrap communications
                             test failed.
709-181     D        261      Description: Could not perform because the
                             device driver detected a hardware error.
709-182     D        261      Description: The data wrap communication
                             test failed.
709-183     D        261      Description: The modem control line test
                             failed.
709-251     D        709      Description: Could not perform because the
                             device driver detected a hardware error.
                    837

709-252     D        709      Description: The data wrap communication
                             test failed.
                    837

709-253     D        709      Description: The modem control line test
                             failed.
                    837

709-254     D        709      Diagnostics: Cannot run the test because
                             the device
                    684      driver detected a hardware error while
                             running the Remote Async Node wrap test.
709-255     D        709      Diagnostics: The data wrap communications
                             test failed while running the Remote Async
                    684      Node wrap test.

709-271     D        709      Description: Could not perform because the
                             device driver detected a hardware error.
                    837

709-272     D        709      Description: The data wrap communication
                             test failed.
                    837

709-273     D        709      Description: The modem control line test
                             failed.
                    837

709-274     D        709      Diagnostics: Cannot run the test because
                             the device
                    684      driver detected a hardware error while
                             running the Printer/Terminal cable wrap
                             test.
709-275     D        709      Diagnostics: The data wrap communications
                             test failed while running the
                    684      Printer/Terminal cable wrap test.

709-281     D        709      Description: Could not perform because the
                             device driver detected a hardware error.
                    837

709-282     D        709      Description: The data wrap communication
                             test failed.
                    837

709-283     D        709      Description: The modem control line test
                             failed.
                    837

709-481     D        D56      Description: Could not do the test because
                             the device driver detected a hardware
                             error.
709-482     D        D56      Description: The data wrap communication
                             test failed.
709-483     D        D56      Description: The modem control line test
                             failed.
709-901     D     software    Description: An unexpected error occurred
                             that can be attributed to software or
   to               709      hardware.
709-920                      Action: Run diagnostics from a source other
                             than from the disk or a network. If the
                             same error occurs or if the original SRN
                             was not obtained from disk or a network
                             based diagnostics, use Chapter 12. "MAP
                             0210: General Problem Resolution" with a
                             FFC of 709; otherwise, suspect a software
                             problem.
709-921     D        709      Description: The adapter failed to
                             configure
                  software

709-922     D     software    Description: An unexpected error occurred
                             that can be attributed to software or
   to               709      hardware.
709-924                      Action: Run diagnostics from a source other
                             than from the disk or a network. If the
                             same error occurs or if the original SRN
                             was not obtained from disk or a network
                             based diagnostics, use Chapter 12. "MAP
                             0210: General Problem Resolution" with a
                             FFC of 709; otherwise, suspect a software
                             problem.
709-925     D        709      Description: The adapter failed to
                             configure
                  software

709-926     D     software    Description: An unexpected error occurred
                             that can be attributed to software or
   to               709      hardware.
709-943                      Action: Run diagnostics from a source other
                             than from the disk or a network. If the
                             same error occurs or if the original SRN
                             was not obtained from disk or a network
                             based diagnostics, use Chapter 12. "MAP
                             0210: General Problem Resolution" with a
                             FFC of 709; otherwise, suspect a software
                             problem.
721-102     D        721      Description: Unknown SCSI or device error.
   to
721-114
721-116     D                 Description: A protocol error.
                             Action: Check the levels of the device,
                             adapter, diagnostic software, and
                             application software to be sure they are
                             all compatible. If you do not find a
                             problem, call your support person.
721-117     D        721      Description: A write protect error
                             occurred.
721-118     D        721      Description: A SCSI command time-out.

                    B88

721-120     D        721      Description: Unknown SCSI or device error.
   to
721-124
721-126     D        721      Description: A software error was caused
                             by a hardware failure.
                    B88

721-128     G        721      Description: The error log analysis
                             indicates a hardware failure.
721-130     G        721      Description: The error log analysis
                             indicates a hardware failure.
                    B88

721-132     D        721      Description: A disk drive hardware error
                             occurred.
721-135     D        721      Description: The device failed to
                             configure.
                    B88
                  software

722-xxx     D        722      Description: Unknown disk drive type is
                             failing.
723-xxx     D        723      Description: Unknown CD-ROM type is
                             failing.
724-xxx     D        724      Description: Unknown tape drive failure.

733-110     D        733      Description: The Reserve command failed,
                             or the Inquiry command failed.
   to

733-120
733-130     D        733      Description: The Load command failed, or
                             the Unload command failed.
   to              media

733-135
733-140     D        733      Description: The Mode Select command
                             failed.
733-150     D        733      Description: The Test Unit Ready command
   to                        failed, or the Send Diagnostic command
733-169            media     failed.

733-170     D        733      Description: The Read, Write and Compare
                             test failed.
                    B88

                   media

733-180     D        733      Description: The Load command failed, or
                             the Unload command failed.
   to              media

733-185
733-190     D        733      Description: The Mode Select command
                             failed.
733-200     D        733      Description: The Test Unit Ready command
                   media     failed.

733-210     D        733      Description: The device configuration
                             failed.
                    B88

733-220     D        733      Description: 140GB 8mm tape drive failed.
   to
733-240
733-300     D        733      Description: The device configuration
                             failed.
                  software

733-310     D        B88      Description: SCSI adapter configuration
                    733      failed.

                  software

733-320     G        733      Description: Error log analysis indicates
                             a failure.
                   media

733-411     D        733      Description: A reservation conflict
   to                        occurred.
733-423             B88
                  software

733-511     D        733      Description: The drive returned bad or
   to                        non-extended sense data.
733-523             B88

733-611     D        733      Description: An adapter, device, or bus
   to                        I/O error occurred.
733-723             B88

                  software

734-111     D        734      Description: Unable to reserve device.

                    B88

734-112     D        734      Description: Unable to do configuration.

                    B88

734-113     D        734      Description: Unable to open the device
                             driver.
                    B88

734-121     D        734      Description: The CD-ROM drive indicates an
                             error.
734-122     D        734      Description: The CD-ROM drive indicates an
                             error.
734-123     D        734      Description: The CD-ROM drive indicates an
                             error.
734-125     D        734      Description: The CD-ROM drive indicates an
                             error.
                    B88

734-126     D        734      Description: The CD-ROM drive indicates an
                             error.
734-127     D        734      Description: The CD-ROM drive indicates an
                             error.
734-128     D        734      Description: The CD-ROM drive indicates an
                             error.
734-129     D        734      Description: The CD-ROM drive indicates an
                             error.
734-150     D       Media     Description: A media error was detected.

                    734

734-151     D        734      Description: A command timeout was
                             detected.
                    D88

734-152     D        734      Description: A command reservation
                             conflict was detected.
734-162     D        734      Description: The CD-ROM drive indicates an
                             error.
734-171     D        734      Description: Unable to reserve device.

734-172     D        734      Description: Unable to do configuration.

734-173     D        734      Description: Unable to open device driver.

734-175     D        734      Description: The CD-ROM drive indicates an
                             error.
734-198     D        734      Description: Undefined error detected.

                    B88

734-199     D        734      Description: Undefined error detected.

734-211     D        734      Description: The LED test failed.

734-281     D        734      Description: No tone during audio test.

734-301     G        734      Description: Errors found during ELA.

734-302     G        734      Description: Errors found during ELA.

                    B88

736-101     D        821      Description: An unexpected adapter error
                             occurred.
736-102     D        736      Description: An unexpected device or
                             adapter error occurred.
                    821

736-103     D        736      Description: The keyboard reset failed.

                    821

736-104     D        736      Description: Unknown keyboard.

736-105     D        736      Description: The keyboard light on test
                             failed.
                    821

736-106     D        736      Description: The keyboard light off test
                             failed.
                    821

736-201     D        821      Description: An unexpected adapter error
                             occurred.
736-202     D        736      Description: An unexpected device or
                             adapter error occurred.
                    821

736-203     D        736      Description: The read keyboard ID test
                             failed.
                    821

736-204     D        736      Description: The keyboard layout ID test
                             failed.
736-205     D        736      Description: The keyboard echo test
                             failed.
                    821

736-206     D        736      Description: The select scan code set test
                             failed.
                    821

736-301     D        821      Description: An unexpected adapter error
                             occurred.
736-302     D        736      Description: An unexpected device or
                             adapter error occurred.

736-303     D        736      Description: An error occurred in turning
                             on the lamps.
736-304     D        736      Description: An error occurred in turning
                             off the lamps.
736-401     D        821      Description: An unexpected adapter error
                             occurred.
736-402     D        736      Description: An unexpected device or
                             adapter error occurred.
                    821

736-403     D        736      Description: Unable to recognize the
                             keyboard.
736-404     D        736      Description: The keyboard is failing.

                    821

736-701     D        736      Description: Error configuring the device.

                    821

736-901     G        821      Description: The error log analysis
                             indicates an adapter failure.
736-902     G        736      Description: The error log analysis
                             indicates a device failure.
                    821

736-903     G        736      Description: The error log analysis
                             indicates an unknown failure.
                    821

741-102     D        741      Description: SCSI disk drive problems.
   to
741-114
741-116     D                 Description: A protocol error.
                             Action: Check the levels of the device,
                             adapter, diagnostic software, and
                             application software to be sure they are
                             all compatible. If you do not find a
                             problem, call your support person.
741-117     D        741      Description: A write protect error
                             occurred.
741-118     D        741      Description: A SCSI command timeout.

                    B88

741-120     D        741      Description: SCSI disk drive problems.
   to
741-124
741-126     D        741      Description: A software error was caused
                             by a hardware failure.
                    B88

741-128     G        741      Description: The error log analysis
                             indicates a hardware failure.
741-129     G        D50      Description: Error log analysis indicates
                             a SCSI bus problem.
                    741

                    B88

                  software

741-130     G        741      Description: Error log analysis indicates
                             a problem reported by the disk drive's self
                             monitoring function.
741-132     D        741      Description: A disk drive hardware error
                             occurred.
741-134     D        B88      Description: The adapter failed to
                             configure.
                  software

741-135     D        741      Description: The device failed to
                             configure.
                    B88
                  software

741-137     D        741      Description: Unit attention condition has
                             occurred on the Send Diagnostic command.
                    B88

                    D50

742-101     D        742      Description: Configuration register test
                             failed
742-102     D        742      Description: I/O register test failed

742-104     D        742      Description: Internal loopback test failed

742-105     D        742      Description: Internal loopback test failed

742-106     D        742      Description: External loopback test failed

742-121     D        D59      Description: Configuration register test
                             failed
742-122     D        D59      Description: I/O register test failed

742-124     D        D59      Description: Internal loopback test failed

742-125     D        D59      Description: Internal loopback test failed

742-126     D        D59      Description: External loopback test failed

742-141     D        D60      Description: Configuration register test
                             failed
742-142     D        D60      Description: I/O register test failed

742-144     D        D60      Description: Internal loopback test failed

742-145     D        D60      Description: Internal loopback test failed

742-160     D        B08      Description: 10Base-T transceiver test
                             failed
742-161     D        B09      Description: 10Base-2 transceiver test
                             failed
742-203     D        742      Description: Device configuration failed

                  software

742-223     D        D59      Description: Device configuration failed

                  software

742-224     D        B08      Description: 10 Base-T transceiver test
                             failed
                    D59

742-225     D        B09      Description: 10 Base-2 transceiver test
                             failed
                    D59

742-243     D        D60      Description: Device configuration failed

                  software

742-700     G        742      Description: Error log analysis indicates
                             a hardware problem
                  software

742-720     G        D59      Description: Error log analysis indicates
                             a hardware problem
                  software

742-740     G        D60      Description: Error log analysis indicates
                             a hardware problem
                  software

745-100     D       media     Description: Recovered error.
                             Action: No action required.
                    745

745-200     D       media     Description: Drive Not Ready.
                             Action: Install media, refer to the tape
                    745      autoloader service guide.

745-300     D       media     Description: 4mm Tape Auto Loader problem.
   to
745-350             745      Action: Replace media, clean drive, refer
                             to the tape autoloader service guide.
745-400     D        745      Description: General Hardware Failure.
                             Action: Replace media, clean drive, refer
                  magazine   to the tape autoloader service guide.

                   media

745-410     D        745      Description: Internal Hardware Failure
   to                        Action: Replace drive, refer to the tape
745-435            media     autoloader service guide.

745-440     D        745      Description: SCSI Hardware Failure.
                             Action: Replace drive, refer to the tape
                    SCSI     autoloader service guide.

                  Adapter

745-441     D        745      Description: 4mm Tape Auto Loader problem.
   to
745-443            media     Action: Replace drive, refer to the tape
                             autoloader service guide.
745-444     D        745      Description: Humidity too High
                             Action: Lower humidity, replace media,
                  environ-   refer to the tape autoloader service guide.

                    ment

                   media

745-445     D       clean     Description: Drive Requires Cleaning
                             Action: Clean drive, replace media, refer
                   media     to the tape autoloader service guide.

                   drive

745-460     D        745      Description: Magazine Movement Failure
   to                        Action: Check magazine and media, clean
745-465           magazine   rollers, refer to the tape autoloader
                             service guide.
                   media

745-470     D        745      Description: Media Insert/Eject Failure
   to                        Action: Check clean magazine and media,
745-475           magazine   clean rollers, refer to the tape autoloader
                             service guide.
                   media

745-480     D        745      Description: Drawer Open/Close Failure
   to                        Action: Check magazine and media, refer to
745-485           magazine   the tape autoloader service guide.

                   media

745-500     D        745      Description: Illegal request to drive
                             Action: Software conflict, refer to the
                   system    tape autoloader service guide.

745-600     D        745      Description: Unit Attention
                             Action: Software conflict, media changed,
                   system    refer to the tape autoloader service guide.

745-700     D        745      Description: Not Writeable
                             Action: Check media for write protect,
                   media     refer to the tape autoloader service guide.

745-800     D        745      Description: Blank Media
                             Action: Check media, refer to the tape
                   media     autoloader service guide.

745-B00     D        745      Description: SCSI Interface Failure
                             Action: Check SCSI interface, refer to the
                    SCSI     tape autoloader service guide.

                  Adapter

745-D00     D        745      Description: Tape Full
                             Action: Check replace media, refer to the
                   media     tape autoloader service guide.

746-212     D        746      Description: FIFO empty bit set.
                             Action: Go to Chapter 7. "MAP 0050: SCSI
                    221      Problems Isolation Procedure".

746-213     D        746      Description: FIFO empty bit clear.
                             Action: Go to Chapter 7. "MAP 0050: SCSI
                    221      Problems Isolation Procedure".

746-214     D        746      Description: FIFO full bit set.
                             Action: Go to Chapter 7. "MAP 0050: SCSI
                    221      Problems Isolation Procedure".

746-215     D        746      Description: FIFO full bit clear.
                             Action: Go to Chapter 7. "MAP 0050: SCSI
                    221      Problems Isolation Procedure".

746-216     D        746      Description: FIFO data miscompare.
                             Action: Go to Chapter 7. "MAP 0050: SCSI
                    221      Problems Isolation Procedure".

746-217     D        746      Description: SCSI FIFO data miscompare.
                             Action: Go to Chapter 7. "MAP 0050: SCSI
                    221      Problems Isolation Procedure".

746-218     D        746      Description: SCSI FIFO underflow.
                             Action: Go to Chapter 7. "MAP 0050: SCSI
                    221      Problems Isolation Procedure".

746-219     D        746      Description: SCSI parity error.
                             Action: Go to Chapter 7. "MAP 0050: SCSI
                    221      Problems Isolation Procedure".

746-220     D        746      Description: SCSI FIFO flags error.
                             Action: Go to Chapter 7. "MAP 0050: SCSI
                    221      Problems Isolation Procedure".

746-221     D        746      Description: Miscompare during the
                             write/read of the configuration register.
                    221      Action: Go to Chapter 7. "MAP 0050: SCSI
                             Problems Isolation Procedure".
746-222     D        746      Description: Error during the write/read
                             of the memory register.
                    221      Action: Go to Chapter 7. "MAP 0050: SCSI
                             Problems Isolation Procedure".
746-223     D        746      Description: Miscompare during the
                             write/read of the memory I/O register.
                    221      Action: Go to Chapter 7. "MAP 0050: SCSI
                             Problems Isolation Procedure".
746-224     D        746      Description: Error reading the PCI
                             configuration register.
                    221

746-225     D        746      Description: Adapter POST failed.

                    221

746-230     D        D50      Description: Arbitration test failed.
                             Action: Go to Chapter 7. "MAP 0050: SCSI
                    746      Problems Isolation Procedure".

746-231     D        D50      Description: Function could not complete.
                             Action: Go to Chapter 7. "MAP 0050: SCSI
                    746      Problems Isolation Procedure".

746-232     D        D50      Description: SCSI bus data miscompare.
                             Action: Go to Chapter 7. "MAP 0050: SCSI
                    746      Problems Isolation Procedure".

746-240     D        746      Description: No terminal power.
                             Action: Go to Chapter 7. "MAP 0050: SCSI
                    221      Problems Isolation Procedure".

746-301     D        746      Description: Configuration open failed for
                             parent bus.
                    D50

                  software

746-700     G        746      Description: Error log analysis indicates
                             a PCI SCSI adapter failure.
                  software

746-701     G        746      Description: Error log analysis indicates
                             a PCI SCSI adapter failure.
                  software

746-702     G        746      Description: Error log analysis indicates
                             a PCI SCSI adapter failure.
                  software

746-703     G        746      Description: Error log analysis indicates
                             a PCI SCSI adapter failure.
                  software

746-704     G        746      Description: Error log analysis indicates
                             a PCI SCSI adapter failure.
                  software

746-705     G        746      Description: Error log analysis indicates
                             a PCI SCSI adapter failure.
                  software

746-800     G        746      Description: Error log analysis indicates
                             a PCI SCSI adapter PTC failure.
                             Action: Go to Chapter 7. "MAP 0050: SCSI
                             Problems Isolation Procedure".
746-802     G        746      Description: Error log analysis indicates
                             a PCI SCSI bus failure.
                             Action: Go to Chapter 7. "MAP 0050: SCSI
                             Problems Isolation Procedure".
747-212     D        747      Description: FIFO empty bit set.
                             Action: Go to Chapter 7. "MAP 0050: SCSI
                    221      Problems Isolation Procedure".

747-213     D        747      Description: FIFO empty bit clear.
                             Action: Go to Chapter 7. "MAP 0050: SCSI
                    221      Problems Isolation Procedure".

747-214     D        747      Description: FIFO full bit set.
                             Action: Go to Chapter 7. "MAP 0050: SCSI
                    221      Problems Isolation Procedure".

747-215     D        747      Description: FIFO full bit clear.
                             Action: Go to Chapter 7. "MAP 0050: SCSI
                    221      Problems Isolation Procedure".

747-216     D        747      Description: FIFO data miscompare.
                             Action: Go to Chapter 7. "MAP 0050: SCSI
                    221      Problems Isolation Procedure".

747-217     D        747      Description: SCSI FIFO data miscompare.
                             Action: Go to Chapter 7. "MAP 0050: SCSI
                    221      Problems Isolation Procedure".

747-218     D        747      Description: SCSI FIFO underflow.
                             Action: Go to Chapter 7. "MAP 0050: SCSI
                    221      Problems Isolation Procedure".

747-219     D        747      Description: SCSI parity error.
                             Action: Go to Chapter 7. "MAP 0050: SCSI
                    221      Problems Isolation Procedure".

747-220     D        747      Description: SCSI FIFO flags error.
                             Action: Go to Chapter 7. "MAP 0050: SCSI
                    221      Problems Isolation Procedure".

747-221     D        747      Description: Miscompare during the
                             write/read of the configuration register.
                    221      Action: Go to Chapter 7. "MAP 0050: SCSI
                             Problems Isolation Procedure".
747-222     D        747      Description: Error during the write/read
                             of the memory register.
                    221      Action: Go to Chapter 7. "MAP 0050: SCSI
                             Problems Isolation Procedure".
747-223     D        747      Description: Miscompare during the
                             write/read of the memory I/O register.
                    221      Action: Go to Chapter 7. "MAP 0050: SCSI
                             Problems Isolation Procedure".
747-224     D        747      Description: Error reading the PCI
                             configuration register.
                    221

747-225     D        747      Description: Adapter POST failed.

                    221

747-230     D        D50      Description: Arbitration test failed.
                             Action: Go to Chapter 7. "MAP 0050: SCSI
                    747      Problems Isolation Procedure".

747-231     D        D50      Description: Function could not complete.
                             Action: Go to Chapter 7. "MAP 0050: SCSI
                    747      Problems Isolation Procedure".

747-232     D        D50      Description: SCSI bus data miscompare.
                             Action: Go to Chapter 7. "MAP 0050: SCSI
                    747      Problems Isolation Procedure".

747-240     D        747      Description: No terminal power.
                             Action: Go to Chapter 7. "MAP 0050: SCSI
                    221      Problems Isolation Procedure".

747-301     D        747      Description: Configuration open failed for
                             parent bus.
                    D50

                  software

747-700     G        747      Description: Error log analysis indicates
                             a PCI SCSI adapter failure.
                  software

747-701     G        747      Description: Error log analysis indicates
                             a PCI SCSI adapter failure.
                  software

747-702     G        747      Description: Error log analysis indicates
                             a PCI SCSI adapter failure.
                  software

747-703     G        747      Description: Error log analysis indicates
                             a PCI SCSI adapter failure.
                  software

747-704     G        747      Description: Error log analysis indicates
                             a PCI SCSI adapter failure.
                  software

747-705     G        747      Description: Error log analysis indicates
                             a PCI SCSI adapter failure.
                  software

747-800     G        747      Description: Error log analysis indicates
                             a PCI SCSI adapter PTC failure.
                             Action: Go to Chapter 7. "MAP 0050: SCSI
                             Problems Isolation Procedure".
747-802     G        747      Description: Error log analysis indicates
                             a PCI SCSI bus failure.
                             Action: Go to Chapter 7. "MAP 0050: SCSI
                             Problems Isolation Procedure".
749-xxx     D        749      Description: 7331 Model 205 Tape Library.
                             Refer to service documentation for this
                             device.
750-100     D        750      Description: The adapter open test failed.

750-200     D        750      Description: Config register test failed.

                    221

750-201     D        750      Description: I/O register test failed.

                    221

750-202     D        750      Description: Adapter self-test failed.

                    221

750-300     D        256      Description: The connect test failed.

                    750

                    221

750-301     D        256      Description: Token-ring internal wrap test
                             failure.
                    750

                    221

750-302     D        256      Description: Token-ring external wrap
                             failure
                    750

                    221

750-303     D        256      Description: Token-ring initialization
                             test failure
                    750

                    221

750-400     D        240      Description: The connect test failed.

                    256

                    750

                    221

750-401     D        240      Token-ring internal wrap test failure

                    256

                    750

                    221

750-402     D        240      Token-ring external wrap test failure

                    256

                    750

                    221

750-403     D        240      Token-ring initialization test failure

                    256

                    750

                    221

750-700     G        750      Description: Error Log analysis indicated
                             a hardware failure.
                    221

751-101     D        751      Description: The PCI wrap test failed

                    227

751-102     D        751      Description: The POST indicates an adapter
                             failure.
751-103     D        751      Description: The POST indicates an adapter
                             channel failure.
751-104     D       Cable     Description: The POST indicates a
                             defective cable.
751-105     D    Backplane/   Description: The POST indicates a
                             defective backplane or external enclosure.
                  Ext.Encl   Action: If the disk devices are located in
                             an external enclosure, refer to the service
                             documentation for the external enclosure.
751-106     D       Disk      Description: The POST indicates a disk
                             failure.
751-107     D        751      Description: The POST indicates a firmware
                             failure.
751-108     D        751      Description: The NVRAM test indicates an
                             adapter firmware failure.
751-109     D        751      Description: The NVRAM test indicates an
                             adapter failure.
751-110     D       Disk      Description: The disk reported a
                             Predictive Failure Analysis error (PFA).
751-111     D       Disk      Description: The disk drive has been
                             failed by the adapter.
751-112     G       Disk      Description: ELA indicates that the disk
                             reported a irrecoverable equipment error.
751-113     G       Disk      Description: ELA indicates that the disk
                             reported a irrecoverable data error.
757-110     D        757      Description: The Reserve command failed.

757-120     D        757      Description: The Inquiry command failed.

757-130     D        757      Description: The Load command failed.

                   media

757-135     D        757      Description: The Unload command failed.

                   media

757-140     D        757      Description: The Mode Select command
                             failed.
757-150     D        757      Description: The Test Unit Ready command
                             failed.
                   media

757-160     D        757      Description: The Send Diagnostic command
                             failed.
                   media

757-169     D        757      Description: The send diagnostic command
                             failed.
                   media

757-170     D        757      Description: The Read, Write and Compare
                             test failed.
                    B88

                   media

757-180     D        757      Description: The Load command failed.

                   media

757-185     D        757      Description: The Unload command failed.

                   media

757-190     D        757      Description: The Mode Select command
                             failed.
757-200     D        757      Description: The Test Unit Ready command
                             failed.
                   media

757-210     D        757      Description: The device configuration
                             failed.
                    B88

757-220     D        757      Description: The Release command failed.

757-230     D        757      Description: The Request Sense command
                             failed.
757-240     D        757      Description: The Openx command failed.

757-300     D        757      Description: The device configuration
                             failed.
                  software

757-310     D        B88      Description: SCSI adapter configuration
                             failed.
                    757

                  software

757-320     D        757      Description: Error log analysis indicates
                             a failure.
                   media

757-411     D        757      Description: A reservation conflict
   to                        occurred.
757-423             B88

                  software

757-511     D        757      Description: The drive returned bad or
   to                        non-extended sense data.
757-523             B88

757-611     D        757      Description: An adapter or bus I/O error
   to                        occurred.
757-623             B88

                  software

757-711     D        757      Description: A device timeout error
   to                        occurred.
757-723             B88

                  software

772-098                       Description: Disk drive indicates an
            J       772      error.
                    B88

772-099                       Description: Disk drive not found.
            J       772
                    B88

772-102                       Description: An unrecoverable media error.
            D       772

772-104                       Description: The motor failed to restart.
            D       772

772-105                       Description: The drive did not become
            D       772      ready.

772-106                       Description: The electronics card test
            D       772      failed.

772-108                       Description: The bus test failed.
            D       772

772-110                       Description: The media format is
            D       772      corrupted.

772-112                       Description: The diagnostic test failed.
            D       772

772-114                        Description: An unrecoverable hardware
            D       772      error.

772-116                       Description: A protocol error.
            D                Action: Check the levels of the device,
                             adapter, diagnostic software, and
                             application software to be sure they are
                             all compatible. If you do not find a
                             problem, call your support person.
772-117                       Description: A write protect error
            D       772      occurred.

772-118                       Description: A SCSI command time-out.
            D       772
                    B88

772-120                       Description: A SCSI busy or command error.
            D       772

772-122                       Description: A SCSI reservation conflict
            D       772      error.

772-124                       Description: A SCSI check condition error.
            D       772

772-126                       Description: A software error was caused
            D       772      by a hardware failure.
                    B88

772-128                       Description: The error log analysis
            G       772      indicates a hardware failure.

772-129     G        D50      Description: Error log analysis indicates
                             a SCSI bus problem.
                    772

                    B88

                  software

772-130     G        772      Description: Error log analysis indicates
                             a problem reported by the disk drive's self
                             monitoring function.
772-132                       Description: A disk drive hardware error
            D       772      occurred.

772-134                       Description: The adapter failed to
            D       B88      configure.
                  software

772-135     D        772      Description: The device failed to
                    B88      configure.

                  software

772-136                       Description: The certify operation failed.
            D       772

772-137     D        772      Description: Unit attention condition has
                             occurred on the Send Diagnostic command.
                    B88

                    D50

773-098                        Description: Disk drive indicates an
            J       773      error.
                    B88

773-099                       Description: Disk drive not found.
            J       773
                    B88

773-102                       Description: An unrecoverable media error.
            D       773

773-104                       Description: The motor failed to restart.
            D       773

773-105                       Description: The drive did not become
            D       773      ready.

773-106                       Description: The electronics card test
            D       773      failed.

773-108                       Description: The bus test failed.
            D       773

773-110                       Description: The media format is
            D       773      corrupted.

773-112                       Description: The diagnostic test failed.
            D       773

773-114                       Description: An unrecoverable hardware
            D       773      error.

773-116                       Description: A protocol error.
            D                Action: Check the levels of the device,
                             adapter, diagnostic software, and
                             application software to be sure they are
                             all compatible. If you do not find a
                             problem, call your support person.
773-117                       Description: A write protect error
            D       773      occurred.

773-118                       Description: A SCSI command time-out.
            D       773
                    B88

773-120                       Description: A SCSI busy or command error.
            D       773

773-122                       Description: A SCSI reservation conflict
            D       773      error.

773-124                        Description: A SCSI check condition
            D       773      error.

773-126                       Description: A software error was caused
            D       773      by a hardware failure.
                    B88

773-128                       Description: The error log analysis
            G       773      indicates a hardware failure.

773-129     G        D50      Description: Error log analysis indicates
                             a SCSI bus problem.
                    773

                    B88

                  software

773-130     G        773      Description: Error log analysis indicates
                             a problem reported by the disk drive's self
                             monitoring function.
773-132                       Description: A disk drive hardware error
            D       773      occurred.

773-134                       Description: The adapter failed to
            D       B88      configure.
                  software

773-135     D        773      Description: The device failed to
                    B88      configure.

                  software

773-136                       Description: The certify operation failed.
            D       773

773-137     D        773      Description: Unit attention condition has
                             occurred on the Send Diagnostic command.
                    B88

                    D50

774-098     J        774      Description: Disk drive indicates an
                             error.
                    B88

774-099                       Description: Disk drive not found.
            J       774
                    B88

774-102                       Description: An unrecoverable media error.
            D       774

774-104                       Description: The motor failed to restart.
            D       774

774-105                       Description: The drive did not become
            D       774      ready.

774-106                       Description: The electronics card test
            D       774      failed.

774-108                       Description: The bus test failed.
            D       774

774-110                       Description: The media format is
            D       774      corrupted.

774-112                       Description: The diagnostic test failed.
            D       774

774-114                       Description: An unrecoverable hardware
            D       774      error.

774-116                       Description: A protocol error.
            D                Action: Check the levels of the device,
                             adapter, diagnostic software, and
                             application software to be sure they are
                             all compatible. If you do not find a
                             problem, call your support person.
774-117                       Description: A write protect error
            D       774      occurred.

774-118                       Description: A SCSI command time-out.
            D       774
                    B88

774-120                       Description: A SCSI busy or command error.
            D       774

774-122                       Description: A SCSI reservation conflict
            D       774      error.

774-124                        Description: A SCSI check condition
            D       774      error.

774-126                       Description: A software error was caused
            D       774      by a hardware failure.
                    B88

774-128                       Description: The error log analysis
            G       774      indicates a hardware failure.

774-129     G        D50      Description: Error log analysis indicates
                             a SCSI bus problem.
                    774

                    B88

                  software

774-130     G        774      Description: Error log analysis indicates
                             a problem reported by the disk drive's self
                             monitoring function.
774-132                       Description: A disk drive hardware error
            D       774      occurred.

774-134                       Description: The adapter failed to
            D       B88      configure.
                  software

774-135     D        774      Description: The device failed to
                    B88      configure.

                  software

774-136                       Description: The certify operation failed.
            D       774

774-137     D        774      Description: Unit attention condition has
                             occurred on the Send Diagnostic command.
                    B88

                    D50

775-001     D        775      Description: "NO" to color panel

                    227

                  Monitor

775-002     D        775      Description: "NO" to cursor panel

                  Monitor

775-007     D     Info code   Description: The EMC_SCROLLING_17_H_TEST
                             failed
775-009     D     Info code   Description: The EMC_SCROLLING_21_H_TEST
                             failed
775-064     D        775      Description: TRIO64V+_TIMEOUT

                    227

775-101     D        775      Description: Color miscompare

                    227

775-102     D        775      Description: Clipping error

                    227

775-103     D        775      Description: Rectangle fill test failed

                    227

775-128     D     software    Description: MALLOC_ERROR

                    775

775-161     D     software    Description: Loop count value in rules
                             file is zero
775-191     D        775      Description: Red screen error

                    227

775-193     D        775      Description: Green screen error

                    227

775-1FF     D        775      Description: Rectangle fill test failed

                    227

775-201     D        775      Description: Color miscompare

                    227

775-202     D        775      Description: Clipping error

                    227

775-203     D        775      Description: Image transfer across Plane
                             Test failed
                    227

775-211     D     software    Description: INTERNAL_ERROR_DATA_SIZE

775-212     D     software    Description: INTERNAL_ERROR_NO_ACCESS

775-215     D        775      Description: Black screen error

                    227

775-217     D        775      Description: 9 x 7 Cross hatch grid
                             failed.
                    227

775-233     D     software    Description: OPEN_RCM_ERROR

775-234     D     software    Description: IOCTL_GSC_HANDLE_FAILED

775-235     D     software    Description: AIXGSC_MAKE_GP_FAILED

775-236     D     software    Description: AIXGSC_UNMAKE_GP_FAILED

775-237     D     software    Description: DEVICE_BUSY_ERROR

775-241     D     Info code   Description: The SCROLLING_17_H_TEST
                             failed.
775-263     D     Info code   Description: The EMC_SCROLLING_21_H_TEST
                             failed
775-2FF     D        775      Description: Image transfer across Plane
                             Test failed
                    227

775-301     D        775      Description: A write of "0x00" to the
                             palette register failed
                    227

775-302     D        775      Description: A write of "0x15" to the
                             palette register failed
                    227

775-303     D        775      Description: A write of "0x2A" to the
                             palette register failed
                    227

775-304     D        775      Description: A write of "0x3F" to the
                             palette register failed
                    227

775-305     D        775      Description: The test of the palette
                             registers failed
                    227

775-3FF     D        775      Description: The test of the palette
                             registers failed
                    227

775-401     D        775      Description: Frame buffer base address
                             inconsistent
                    227

775-402     D        775      Description: VRAM inaccessible

                    227

775-403     D        775      Description: Miscompare found in VRAM

                    227

775-404     D        775      Description: The test of the VRAM failed

                    227

775-447     D        775      Description: Green screen error

                    227

775-449     D        775      Description: Blue Screen error

                    227

775-471     D        775      Description: 9 x 7 Cross hatch grid
                             failed.
                    227

775-473     D        775      Description: 11 x 9 Cross hatch grid
                             failed.
                    227

775-495     D     Info code   Description: The SCROLLING_17_H_TEST
                             failed.
775-497     D     Info code   Description: The SCROLLING_21_H_TEST
                             failed.
775-4FF     D        775      Description: The test of the VRAM failed

                    227

775-501     D        775      Description: Color miscompare

                    227

775-502     D        775      Description: Clipping error

                    227

775-503     D        775      Description: Direct Frame Buffer test
                             failed
                    227

775-5FF     D        775      Description: Direct Frame Buffer test
                             failed
                    227

775-601     D        775      Description: Video Stream Register test
                             failed
                    227

775-602     D        775      Description: Video Stream hardware test
                             failed
                    227

775-6FF     D        775      Description: Video Stream hardware test
                             failed
                    227

775-701     D        775      Description: 0 Degree Short Stroke Draw
                             failed
                    227

775-702     D        775      Description: 45 Degree Short Stroke Draw
                             failed
                    227

775-703     D        775      Description: Blue Screen error, or 90
                             Degree Short Stroke Draw failed
                    227

775-704     D        775      Description: 135 Degree Short Stroke Draw
                             failed
                    227

775-705     D        775      Description: White screen error, or 180
                             Degree Short Stroke Draw failed
                    227

775-706     D        775      Description: 225 Degree Short Stroke Draw
                             failed
                    227

775-707     D        775      Description: 270 Degree Short Stroke Draw
                             failed
                    227

775-708     D        775      Description: 315 Degree Short Stroke Draw
                             failed
                    227

775-709     D        775      Description: Short Stroke Vector Function
                             test failed
                    227

775-727     D        775      Description: 11 x 9 Cross hatch grid
                             failed.
                    227

775-750     D     Info code   Description: The SCROLLING_21_H_TEST
                             failed.
775-753     D     Info code   Description: The EMC_SCROLLING_17_H_TEST
                             failed
775-7FE     D        775      Description: Short Stroke Vector Function
                             test failed
                    227

775-7FF     D     software    Description: Bad vector detected

                    775

                    227

775-801     D        775      Description: Color for PatBlt thru screen
                             failed
                    227

775-802     D        775      Description: Clipping for PatBlt thru
                             screen failed
                    227

775-803     D        775      Description: Color for PatBlt Across
                             screen failed
                    227

775-804     D        775      Description: Clipping for PatBlt Across
                             screen failed
                    227

775-805     D        775      Description: Pattern Fill Across the Plane
                             test failed
                    227

775-8FF     D        775      Description: Pattern Fill Across the Plane
                             test failed
                    227

775-901     D        775      Description: Color miscompare of white
                             boxes detected
                    227

775-902     D        775      Description: Clipping error of white boxes
                             detected
                    227

775-903     D        775      Description: Color miscompare of color
                             bars detected
                    227

775-904     D        775      Description: Clipping error of white boxes
                             detected
                    227

775-905     D        775      Description: Color miscompare of white
                             boxes detected
                    227

775-906     D        775      Description: Clipping error of white boxes
                             detected
                    227

775-907     D        775      Description: Color miscompare of white
                             boxes detected
                    227

775-908     D        775      Description: Clipping miscompare of white
                             boxes detected
                    227

775-909     D        775      Description: The Area fill test (color
                             bars) failed
                    227

775-9FF     D        775      Description: The Area fill test (color
                             bars) failed
                    227

775-937     D        775      Description: Red screen error

                    227

775-959     D        775      Description: White screen error

                    227

775-961     D        775      Description: Black screen error

                    227

775-A01     D        775      Description: Color miscompare of
                             horizontal top line
                    227

775-A02     D        775      Description: Clipping error of horizontal
                             top line
                    227

775-A03     D        775      Description: Color miscompare of vertical
                             right line
                    227

775-A04     D        775      Description: Clipping error of vertical
                             right line
                    227

775-A05     D        775      Description: Color miscompare of
                             horizontal bottom line
                    227

775-A06     D        775      Description: Clipping error of horizontal
                             bottom line
                    227

775-A07     D        775      Description: Color miscompare of vertical
                             left line
                    227

775-A08     D        775      Description: Clipping error of vertical
                             left line
                    227

775-A09     D        775      Description: Color miscompare of
                             horizontal center line
                    227

775-A0A     D        775      Description: Clipping error of horizontal
                             center line
                    227

775-A0B     D        775      Description: Color miscompare of vertical
                             center line
                    227

775-A0C     D        775      Description: Clipping error of vertical
                             center line
                    227

775-A0D     D        775      Description: Reserved

                    227

775-A0F     D        775      Description: Reserved

                    227

775-A10     D        775      Description: Color miscompare of textured
                             top line
                    227

775-A11     D        775      Description: Clipping error of textured
                             top line
                    227

775-A12     D        775      Description: Line Drawing Function test
                             failed
                    227

775-AFF     D        775      Description: Line Drawing Function test
                             failed
                    227

775-B01     D        775      Description: Rectangle Area Color
                             miscompare detected
                    227

775-B02     D        775      Description: Rectangle Area Clip error
                             detected
                    227

775-B03     D        775      Description: Clipped Area Horizontal color
                             miscompare (background line color wrong)
                    227

775-B04     D        775      Description: Clipped Area Horizontal clip
                             miscompare (clip of background line wrong)
                    227

775-B05     D        775      Description: Clipped Area Vertical color
                             miscompare (background line color wrong)
                    227

775-B06     D        775      Description: Clipped Area Vertical clip
                             error (clip of background line wrong)
                    227

775-B07     D        775      Description: The clipping function test
                             failed.
                    227

775-BFF     D        775      Description: The clipping function test
                             failed.
                    227

775-C01     D        775      Description: The BIOS read failed.

                    227

775-C02     D        775      Description: The BIOS function test
                             failed.
                    227

775-CFF     D        775      Description: The BIOS function test
                             failed.
                    227

775-D01     D        775      Description: The HW cursor function test
                             failed.
                    227

775-DFF     D        775      Description: The HW cursor function test
                             failed.
                    227

776-104     D        D46      Description: Connect Test Failure

776-105     D        D46      Description: Wrap Test Failure

776-106     D        D46      Description: Wrap Test Failure

776-201     D        776      Description: Configuration Register Test
                             Failure
                    221

776-202     D        776      Description: I/O Test Failure

                    221

776-203     D        776      Description: Adapter On-Card Test Failure

                    221

776-204     D        776      Description: Connect Test Failure

                    221

776-205     D        776      Description: Wrap Test Failure

                    221

776-206     D        776      Description: Wrap Test Failure

                    221

776-304     D        D46      Description: Connect Wrap Test Failure

                    776

                    221

776-305     D        D46      Description: Wrap Test Failure

                    776

                    221

776-306     D        D46      Description: Wrap Test Failure

                    776

                    221

776-404     D        240      Description: Connect Test Failure

                    D46

                    776

                    221

776-405     D        240      Description: Wrap Test Failure

                    D46

                    776

                    221

776-406     D        240      Description: Wrap Test Failure.

                    D46

                    776

                    221

776-414     F        240      Description: Connect Test Failure. This
                             failure occurs if not connected to a
                    D46      functional Token-Ring network.
                             Action: Run advanced diagnostics for this
                    776      resource to obtain correct problem
                             isolation.
                    221

776-415     F        240      Description: Wrap Test Failure. This
                             failure occurs if not connected to a
                    D46      functional Token-Ring network.
                             Action: Run advanced diagnostics for this
                    776      resource to obtain correct problem
                             isolation.
                    221

776-416     F        240      Description: Wrap Test Failure. This
                             failure occurs if not connected to a
                    D46      functional Token-Ring network.
                             Action: Run advanced diagnostics for this
                    776      resource to obtain correct problem
                             isolation.
                    221

776-702     G        776      Description: ELA indicates a Token-Ring
                             adapter check.
                    221

776-703     G        776      Description: ELA indicates that the
                             Token-Ring device driver has experienced a
                    221      DMA failure

776-704     G        776      Description: ELA indicates that the
                             Token-Ring device driver has experienced a
                    221      PCI bus failure

776-705     G        776      Description: ELA indicates that the
                             Token-Ring device driver has seen a
                    221      Programmed I/O (PIO) failure.

777-201     D        777      Description: Configuration Register Test
                             Failure
                    221

777-202     D        777      Description: I/O Test Failure

                    221

777-203     D        777      Description: Adapter initialization test
                             failure
                    221

777-204     D        777      Description: Internal wrap test failure

                    221

777-205     D        777      Description: Internal wrap test failure

                    221

777-206     D        777      Description: External wrap (10Mbps) test
                             failure
                    221

777-207     D        777      Description: Internal wrap test failure

                    221

777-208     D        777      Description: External wrap (100Mbps) test
                             failure
                    221

777-701     G        777      Description: Error log analysis indicates
                             that the adapter is not responding to
                    221      initialization commands.

777-702     G        777      Description: Error Log Analysis indicates
                             that the device driver has detected a PIO
                    221      error which it was unable to correct.

777-703     G        777      Description: Error log analysis indicates
                             that the adapter has been shut down due to
                    221      an unrecoverable error.

777-704     G        777      Description: Error Log Analysis indicates
                             a problem with the EEPROM on the adapter
                    221

780-101     D        780      Description: Adapter logic test failure.

                    227

780-102     D        780      Description: Adapter logic test failure.

780-109     D        780      Description: Adapter channel Input/Output
                             test failure.
780-113     D        780      Description: Adapter Serial Communication
                             Controller (SCC) test failure.
780-114     D        780      Description: Adapter logic test failure.

                    227

780-120     D        780      Description: Adapter could not be detected
                             or configured.
                    227

                  software

780-140     D        271      Description: An error was found with the
                             X.21 interface adapter cable.
                    780

780-150     D        272      Description: An error was found with the
                             X.24 interface adapter cable.
                    780

780-160     D        273      Description: An error was found with the
                             X.35 interface adapter cable.
                    780

780-170     D        780      Description: The adapter hardware failed.

780-180     D        780      Description: The adapter hardware failed.

780-190     D        780      Description: The adapter hardware failed.

780-210     D        780      Description: An error was found on the
                             adapter.
                    185

780-211     D        780      Description: The adapter card POST test
                             failed.
                    227

780-230     D        780      Description: The adapter card hardware
                             failed.
780-232     D        849      Description: The adapter card hardware
                             failed.
                    227

780-240     D        780      Description: The adapter card hardware
                             failed.
780-250     D        185      Description: An error was found on the
                             adapter.
                    780

780-260     D        780      Description: The adapter card hardware
                             failed.
780-270     D        780      Description: The adapter card hardware
                             failed.
780-280     D        780      Description: The adapter card hardware
                             failed.
780-290     D        780      Description: The adapter card hardware
                             failed.
780-300     G        780      Description: An adapter error was found
                             during error log analysis.
780-310     G        780      Description: An adapter error was found
                             during error log analysis.
                    185

780-320     G        780      Description: An adapter error was found
                             during error log analysis.
                    227

780-330     G        780      Description: Error log analysis indicates
                             a hardware problem.
                    227

780-400     D        780      Description: A software error was caused
                             by a hardware failure.
                    227

780-700     D        780      Description: The adapter failed to
                             configure.
                    227

                  software

780-720     D        780      Description: Cable wrap test failed.

780-721     D        780      Description: Port wrap test failed.

780-722     D        780      Description: Cable wrap test failed.

781-101     D        781      Description: ROS POST adapter software
                             initialization error.
                    227

781-102     D        781      Description: Extended DRAM SIP test
                             failed.
781-103     D        781      Description: ROS checksum test failed.

781-104     D        781      Adapter download diagnostics failed

                    227

781-105     D        781      Description: Memory size test failed.

                    227

781-106     D        781      Description: Interface ID test failed.

                    227

781-107     D        781      Description: EIB ID test failed.

                    227

781-108     D        781      Description: ROS version test failed.

                    227

781-109     D        781      Description: DUSCC register test failed.

781-111     D        781      Description: DMA register test failed.

781-112     D        781      Description: X.21 PAL test failed.

781-113     D        781      Description: External wrap test failed.

781-114     D        781      Description: Twin tail logic test failed.

                    227

781-116     D        254      Description: The RS-232 cable wrap test
                             failed.
781-117     D        253      Description: The RS-422A cable wrap test
                             failed.
781-118     D        257      Description: The V.35 cable wrap test
                             failed.
781-119     D        260      Description: The X.21 cable wrap test
                             failed.
781-120     D        781      Description: The adapter was not detected
                             or could not be configured. test failed.
                    227

                  software

781-121     D        781      Description: The 4-port jumper cable
                             assembly wrap test failed.
                    227

                  software

781-200     G        781      Description: The error log analysis
                             indicates the adapter failed.
781-221     G        781      Description: The error log analysis
                             indicates the adapter hardware failed.
                    227

781-231     D        855      Description: No interface card detected.

                    227

781-501     D        B77      Description: The power-on self-test (POST)
                             failed.
                    B69

                    227

781-502     D        B77      Description: The memory module failed.

781-503     D        781      Description: Adapter hardware failure.

                    227

781-504     D        B69      Description: Adapter hardware failure.

781-505     D        B71      Description: Adapter hardware failure.

                    B69

781-506     D        B72      Description: Adapter hardware failure.

                    B69

781-507     D        B73      Description: Adapter hardware failure.

                    B69

781-508     D        B74      Description: Adapter hardware failure.

                    B69

781-516     D        B77      Description: Adapter Test Failure

                    B69

781-517     D        B69      Description: Adapter Test Failure

                    B77

781-720     D        258      4-port multiprotocol cable

                    781

783-110     D        783      Description: The Reserve command failed.

783-120     D        783      Description: The Inquiry command failed.

783-130     D        783      Description: The Load command failed.

                   media

783-135     D        783      Description: The Unload command failed.

                   media

783-140     D        783      Description: The Mode Select command
                             failed.
783-150     D        783      Description: The Test Unit Ready command
                             failed.
                   media

783-160     D        783      Description: The Send Diagnostic command
                             failed.
                   media

783-169     D        783      Description: The send diagnostic command
                             failed.
                   media

783-170     D        783      Description: The Read, Write and Compare
                             test failed.
                    B88

                   media

783-180     D        783      Description: The Load command failed.

                   media

783-185     D        783      Description: The Unload command failed.

                   media

783-190     D        783      Description: The Mode Select command
                             failed.
783-200     D        783      Description: The Test Unit Ready command
                             failed.
                   media

783-210     D        783      Description: The device configuration
                             failed.
                    B88

783-220     D        783      Description: The Release command failed.

783-230     D        783      Description: The Request Sense command
                             failed.
783-240     D        783      Description: The Openx command failed.

783-300     D        783      Description: The device configuration
                             failed.
                  software

783-310     D        B88      Description: SCSI adapter configuration
                             failed.
                    783

                  software

783-320     G        783      Description: Error log analysis indicates
                             a failure.
                   media

783-411     D        783      Description: A reservation conflict
   to                        occurred.
783-423             B88

                  software

783-511     D        783      Description: The drive returned bad or
   to                        non-extended sense data.
783-523             B88

783-611     D        783      Description: An adapter or bus I/O error
   to                        occurred.
783-623             B88

                  software

783-711     D        783      Description: A device timeout error
   to                        occurred.
783-723             B88

                  software

784-102     D        784      Description: An unrecoverable media error.

784-104     D        784      Description: The motor failed to restart.

784-105     D        784      Description: The drive did not become
                             ready.
784-106     D        784      Description: The electronics card test
                             failed.
784-108     D        784      Description: The bus test failed.

784-110     D        784      Description: The media format is
                             corrupted.
784-112     D        784      Description: The diagnostic test failed.

784-114     D        784      Description: An unrecoverable hardware
                             error.
784-116     D                 Description: A protocol error.
                             Action: Check the levels of the device,
                             adapter, diagnostic software, and
                             application software to be sure they are
                             all compatible. If you do not find a
                             problem, call your support person.
784-117     D        784      Description: A write protect error
                             occurred.
784-118     D        784      Description: A SCSI command time-out.

                    B88

784-120     D        784      Description: A SCSI busy or command error.

784-122     D        784      Description: A SCSI reservation conflict
                             error.
784-124     D        784      Description: A SCSI check condition error.

784-126     D        784      Description: A software error was caused
                             by a hardware failure.
                    B88

784-128     G        784      Description: The error log analysis
                             indicates a hardware failure.
784-129     G        D50      Description: Error log analysis indicates
                             a SCSI bus problem.
                    784

                    B88

                  software

784-130     G        784      Description: Error log analysis indicates
                             a problem reported by the disk drive's self
                             monitoring function.
784-132     D        784      Description: A disk drive hardware error
                             occurred.
784-134     D        B88      Description: The adapter failed to
                             configure.
                  software

784-135     D        784      Description: The device failed to
                    B88      configure.

                  software

784-136     D        784      Description: The certify operation failed.

784-137     D        784      Description: Unit attention condition has
                             occurred on the Send Diagnostic command.
                    B88

                    D50

785-111     D        785      Could not do the test because the device
                             driver detected a hardware error.
                    227

785-114     D        785      The register verification test failed.

785-121     D        785      Could not do the test because the device
                             driver detected a hardware error.
                    227

785-122     D        785      The data wrap communication test failed.

                    227

785-123     D        785      The modem control line test failed.

                    227

785-124     D        785      The memory test failed.

785-151     D        785      Could not do the test because the device
                             driver detected a hardware error.
                    D57

785-152     D        785      The data wrap communication test failed.

                    D57

785-153     D        785      The modem control line test failed.

                    D57

785-171     D        259      Could not do the test because the device
                             driver detected a hardware error.
785-172     D        259      The data wrap communication test failed.

785-173     D        259      The modem control line test failed.

785-181     D        261      Could not do the test because the device
                             driver detected a hardware error.
785-182     D        261      The data wrap communication test failed.

785-183     D        261      The modem control line test failed.

785-251     D        785      Could not perform because the device
                             driver detected a hardware error.
                    D57

785-252     D        785      The data wrap communication test failed.

                    D57

785-253     D        785      The modem control line test failed.

                    D57

785-271     D        785      Could not perform because the device
                             driver detected a hardware error.
                    D57

785-272     D        785      The data wrap communication test failed.

                    D57

785-273     D        785      The modem control line test failed.

                    D57

785-281     D        785      Could not perform because the device
                             driver detected a hardware error.
                    D57

785-282     D        785      The data wrap communication test failed.

                    D57

785-283     D        785      The modem control line test failed.

                    D57

785-481     D        D57      Could not do the test because the device
                             driver detected a hardware error.
785-482     D        D57      The data wrap communication test failed.

785-483     D        D57      The modem control line test failed.

785-901     D     software    Description: An unexpected error occurred
                             that can be attributed to software or
   to               785      hardware.
785-920                      Action: Run diagnostics from a source other
                             than from the disk or a network. If the
                             same error occurs or if the original SRN
                             was not obtained from disk or a network
                             based diagnostics, use Chapter 12. "MAP
                             0210: General Problem Resolution" with a
                             FFC of 785; otherwise, suspect a software
                             problem.
785-921     D        785      Description: The adapter failed to
                             configure
                  software

785-922     D     software    Description: An unexpected error occurred
                             that can be attributed to software or
   to               785      hardware.
785-924                      Action: Run diagnostics from a source other
                             than from the disk or a network. If the
                             same error occurs or if the original SRN
                             was not obtained from disk or a network
                             based diagnostics, use Chapter 12. "MAP
                             0210: General Problem Resolution" with a
                             FFC of 785; otherwise, suspect a software
                             problem.
785-925     D        785      Description: The adapter failed to
                             configure
                  software

785-926     D     software    Description: An unexpected error occurred
                             that can be attributed to software or
   to               785      hardware.
785-943                      Action: Run diagnostics from a source other
                             than from the disk or a network. If the
                             same error occurs or if the original SRN
                             was not obtained from disk or a network
                             based diagnostics, use Chapter 12. "MAP
                             0210: General Problem Resolution" with a
                             FFC of 785; otherwise, suspect a software
                             problem.
786-200     D        786      Description: Initiation failed

                    D96      Note: You must determine which of the first
                             two FFCs is installed in the system unit.
                    227

786-210     D        786      Description: The adapter test failed

                    227

786-211     D        D96      Description: The adapter test failed

                    227

786-220     D        786      Description: The display test failed

                   Cable

                  Monitor

786-221     D        D96      Description: The display test failed

                   Cable

                  Monitor

786-710     D        786      Description: The ELA indicates HW failure

                    227

786-711     D        D96      The ELA indicates HW failure

                    227

787-100     D        787      GXT500P Graphics Adapter

787-101     D        787      Description: GXT500P Graphics Adapter

                    227

787-1AA     D        787      Description: GXT500P Graphics Adapter

                 RGB Cable

                  Display

787-1xx     D        787      Description: GXT500P Graphics Adapter

787-200     D        D95      Description: GXT550P Graphics Adapter

787-201     D        D95      Description: GXT550P Graphics Adapter

                    227

787-2AA     D        D95      Description: GXT550P Graphics Adapter

                 RGB Cable

                  Display

787-2xx     D        D95      Description: GXT550P Graphics Adapter

788-001     D        788      Description: Adapter Error

                    227

788-002     D     software    Description: System Error

                    788

788-003     D     software    Description: System Error

                    788

788-004     D        788      Description: System Error

                  software

789-101     D        789      Description: Failed to release the device.

789-102     D        789      Description: Failed to reserve the device.

789-103     D        789      Description: The device motor failed to
                             start.
789-104     D        789      Description: Failed to make the device
                             ready.
789-105     D        789      Description: Failed to get the inquiry
                             data.
789-106     D        789      Description: The Prevent Media Removal
                             command failed.
789-107     D        789      Description: The Allow Media Removal
                             command failed.
789-200     D        789      Description: The optical disk failed to
                             load.
                Optical Disk Action: Change the media. Run diagnostics
                             on the changed media in System Verification
                             mode. If the error reoccurs use Chapter 12.
                             "MAP 0210: General Problem Resolution";
                             otherwise, replace the media.
789-201     D        789      Description: Failed to unload the optical
                             disk.
                Optical Disk Action: Change the media. Run diagnostics
                             on the changed media in System Verification
                             mode. If the errors reoccur use Chapter 12.
                             "MAP 0210: General Problem Resolution";
                             otherwise, replace the media.
789-202     D        789      Description: The diagnostic test failed.
                             Action: Change the media. Run diagnostics
                Optical Disk on the changed media in System Verification
                             mode. If errors do not reoccur, replace the
                             media; otherwise, run the drive cleaning
                             procedures if applicable and rerun the
                             diagnostics. If errors reoccur, or the
                             drive does not support the cleaning
                             procedures use Chapter 12. "MAP 0210:
                             General Problem Resolution".
789-204     D        789      Description: The device failed to
                             configure.
                    B88

789-205     D        789      Description: The Test Unit Ready command
                             failed.
                Optical Disk Action: Change the media. Run diagnostics
                             on the changed media in System Verification
                             mode. If the error reoccurs, use Chapter
                             12. "MAP 0210: General Problem Resolution";
                             otherwise, replace the media.
789-206     D        789      Description: The random write, read and
                             compare test failed.
                Optical Disk Action: Change the media. Run diagnostics
                             on the changed media in System Verification
                             mode. If the errors do not reoccur, replace
                             the media; otherwise, run the drive
                             cleaning procedures if applicable, and
                             rerun diagnostics. If the errors reoccur,
                             or the drive does not support cleaning
                             procedures, use Chapter 12. "MAP 0210:
                             General Problem Resolution".
789-207     D        789      Description: A hardware error occurred.
                             Action: Change the media. Run diagnostics
                Optical Disk on the changed media in System Verification
                             mode. If the errors do not reoccur, replace
                             the media; otherwise, run the drive
                             cleaning procedures if applicable, and
                             rerun diagnostics. If the errors reoccur,
                             or the drive does not support cleaning
                             procedures, use Chapter 12. "MAP 0210:
                             General Problem Resolution".
789-208     D        789      Description: The Mode Sense command
                             failed.
                Optical Disk Action: Change the media. Run diagnostics
                             on the changed media in System Verification
                             mode. If the errors do not reoccur, replace
                             the media; otherwise, run the drive
                             cleaning procedures if applicable, and
                             rerun diagnostics. If the errors reoccur,
                             or the drive does not support cleaning
                             procedures, use Chapter 12. "MAP 0210:
                             General Problem Resolution".
789-209     D        789      Description: The Mode Select command
                             failed.
                Optical Disk Action: Change the media. Run diagnostics
                             on the changed media in System Verification
                             mode. If the errors do not reoccur, replace
                             the media; otherwise, run the drive
                             cleaning procedures if applicable, and
                             rerun diagnostics. If the errors reoccur,
                             or the drive does not support cleaning
                             procedures, use Chapter 12. "MAP 0210:
                             General Problem Resolution".
789-300     D        789      Description: A SCSI reservation conflict
                             has occurred.
                    B88

                  software

789-400     D        789      Description: A SCSI command time out has
                             occurred.
                    B88

                   Cables

                  software

789-401     D   Optical Disk  Description: An unknown error has
                             occurred.
                    D50

                    B88

                  software

789-402     D   Optical Disk  Description: Unit attention condition has
                             occurred.
                    D50

                    B88

                  software

789-600     G   Optical Disk  Description: ELA indicates that the spare
                             sectors on the disk are exhausted.
                             Action: Backup the media and replace it.

                             Note: Use the time when the error occurred
                             and the "Spare Sector Availability" service
                             aid to identify the disk that has the
                             error.
789-700     G        789      Description: The ELA indicates an
                             equipment error.
                Optical Disk Action: Run diagnostics in System
                             Verification mode to isolate the problem.
                             If errors are reported, use Chapter 12.
                             "MAP 0210: General Problem Resolution";
                             otherwise, the error is due to faulty
                             media. Backup the media and then replace
                             it.

                             Note: Use the time when the error occurred
                             to identify the faulty media.
789-701     G   Optical Disk  Description: ELA indicates an
                             irrecoverable data error.
                    789      Action: Run diagnostics in System
                             Verification mode to isolate the problem.
                             If errors are reported, use Chapter 12.
                             "MAP 0210: General Problem Resolution";
                             otherwise, the error is due to faulty
                             media. Backup the media and then replace
                             it.

                             Note: Use the time when the error occurred
                             to identify the faulty media.
789-702     G        789      Description: ELA indicates that the
                             adapter detected an error.
                    B88      Action: Use the 7209 Installation and
                             Service Guide. If the unit checks out to be
                   Cables    good, use Chapter 12. "MAP 0210: General
                             Problem Resolution".
790-101     D        790      Description: Configuration Register Test
                             failure
790-102     D        790      Description: I/O test failure

790-103     D        790      Description: Adapter initialization test
                             failure
790-104     D        790      Description: Internal wrap test failure

790-105     D        790      Description: Internal wrap test failure

790-106     D        790      Description: External wrap (10Mbps) test
                             failure
790-107     D        790      Description: Internal wrap test failure

790-108     D        790      Description: External wrap (100Mbps) test
                             failure
790-109     D        790      Description: External wrap (10Mbps) test
                             failure
790-121     D        790      Description: Configuration register test
                             failure
790-122     D        790      Description: I/O register test failure

790-124     D        790      Description: Internal loopback test
                             failure
790-125     D        790      Description: Internal loopback test
                             failure
790-126     D        790      Description: External loopback test
                             failure
790-150     D        B08      Description: 10Base-T transceiver test
                             failure
790-151     D        B09      Description: 10Base-2 transceiver test
                             failure
790-223     D        790      Description: Device configuration failure

                  software

790-224     D        B08      Description: 10 Base-T transceiver test
                             failure
                    790

790-225     D        B09      Description: 10 Base-2 transceiver test
                             failure
                    790

790-250     D        B08      Description: 10 Base-T transceiver test
                             failure
                    790

790-251     D        B09      Description: 10 Base-2 transceiver test
                             failure
                    790

790-701     G        790      Description: Error Log Analysis indicates
                             that the adapter is not responding to
                             initialization commands.
790-702     G        790      Description: Error Log Analysis indicates
                             that the device driver has detected a PIO
                             error which it was unable to correct.
790-703     G        790      Description: Error Log Analysis indicates
                             that the adapter has been shutdown due to
                             an unrecoverable error.
790-704     G        790      Description: Error Log Analysis indicates
                             a problem with EEPROM on the adapter.
790-720     G        790      Description: Error log analysis indicates
                             a hardware problem
                  software

791-098                        Description: The disk drive indicates an
            J       791      error.
                    B88

791-099                        Description: The disk drive not found.
            J       791
                    B88

791-102                        Description: An unrecoverable media error
            D       791      occurred.

791-104                        Description: The motor failed to restart.
            D       791

791-105                        Description: The drive did not become
            D       791      ready.

791-106                        Description: The electronics card test
            D       791      failed.

791-108                        Description: The bus test failed.
            D       791

791-110                        Description: The media format is
            D       791      corrupted.

791-112                        Description: The diagnostic test failed.
            D       791

791-114                        Description: An unrecoverable hardware
            D       791      error.

791-116                        Description: A protocol error.
            D                Action: Check the levels of the device,
                             adapter, diagnostic software, and
                             application software to be sure they are
                             all compatible. If you do not find a
                             problem, call your support person.
791-117                        Description: A write protect error
            D       791      occurred.

791-118                        Description: A SCSI command time-out
            D       791      occurred.
                    B88

791-120                        Description: A SCSI busy or command
            D       791      error.

791-122                        Description: A SCSI reservation conflict
            D       791      error.

791-124                        Description: A SCSI check condition error
            D       791      occurred.

791-126                        Description: A software error was caused
            D       791      by a hardware failure.
                    B88

791-128                        Description: The error log analysis
            G       791      indicates a hardware failure.

791-129     G        D50      Description: Error log analysis indicates
                             a SCSI bus problem.
                    791

                    B88

                  software

791-130     G        791      Description: Error log analysis indicates
                             a problem reported by the disk drive's self
                             monitoring function.
791-132     D        791      Description: A disk drive hardware error
                             occurred.
791-134     D        B88       Description: The adapter failed to
                             configure.
                  software

791-135     D        791      Description: The device failed to
                             configure.
                    B88

                  software

791-136     D        791      Description: The certify operation failed.

791-137     D        791      Description: Unit attention condition has
                             occurred on the Send Diagnostic command.
                    B88

                    D50

792-098                        Description: The disk drive indicates an
            J       792      error.
                    B88

792-099                        Description: The disk drive not found.
            J       792
                    B88

792-102                        Description: An unrecoverable media error
            D       792      occurred.

792-104                        Description: The motor failed to restart.
            D       792

792-105                        Description: The drive did not become
            D       792      ready.

792-106                        Description: The electronics card test
            D       792      failed.

792-108                        Description: The bus test failed.
            D       792

792-110                        Description: The media format is
            D       792      corrupted.

792-112                        Description: The diagnostic test failed.
            D       792

792-114                        Description: An unrecoverable hardware
            D       792      error.

792-116                        Description: A protocol error.
            D                Action: Check the levels of the device,
                             adapter, diagnostic software, and
                             application software to be sure they are
                             all compatible. If you do not find a
                             problem, call your support person.
792-117                        Description: A write protect error
            D       792      occurred.

792-118                        Description: A SCSI command time-out
            D       792      occurred.
                    B88

792-120                        Description: A SCSI busy or command
            D       792      error.

792-122                        Description: A SCSI reservation conflict
            D       792      error.

792-124                        Description: A SCSI check condition error
            D       792      occurred.

792-126                        Description: A software error was caused
            D       792      by a hardware failure.
                    B88

792-128                        Description: The error log analysis
            G       792      indicates a hardware failure.

792-129     G        D50      Description: Error log analysis indicates
                             a SCSI bus problem.
                    792

                    B88

                  software

792-130     G        792      Description: Error log analysis indicates
                             a problem reported by the disk drive's self
                             monitoring function.
792-132                        Description: A disk drive hardware error
            D       792      occurred.

792-134                        Description: The adapter failed to
            D       B88      configure.
                  software

792-135     D        792      Description: The device failed to
                    B88      configure.

                  software

792-136     D        792      Description: The certify operation failed.

792-137     D        792      Description: Unit attention condition has
                             occurred on the Send Diagnostic command.
                    B88

                    D50

793-098     J        793      Description: The disk drive indicates an
                             error.
                    B88

793-099     J        793      Description: The disk drive not found.

                    B88

793-102     D        793      Description: An unrecoverable media error
                             occurred.
793-104                        Description: The motor failed to restart.
            D       793

793-105                        Description: The drive did not become
            D       793      ready.

793-106                        Description: The electronics card test
            D       793      failed.

793-108                        Description: The bus test failed.
            D       793

793-110                        Description: The media format is
            D       793      corrupted.

793-112                        Description: The diagnostic test failed.
            D       793

793-114                        Description: An unrecoverable hardware
            D       793      error.

793-116                        Description: A protocol error.
            D                Action: Check the levels of the device,
                             adapter, diagnostic software, and
                             application software to be sure they are
                             all compatible. If you do not find a
                             problem, call your support person.
793-117                        Description: A write protect error
            D       793      occurred.

793-118                        Description: A SCSI command time-out
            D       793      occurred.
                    B88

793-120                        Description: A SCSI busy or command
            D       793      error.

793-122                        Description: A SCSI reservation conflict
            D       793      error.

793-124                        Description: A SCSI check condition error
            D       793      occurred.

793-126                        Description: A software error was caused
            D       793      by a hardware failure.
                    B88

793-128     G        793      Description: The error log analysis
                             indicates a hardware failure.
793-129     G        D50      Description: Error log analysis indicates
                             a SCSI bus problem.
                    793

                    B88

                  software

793-130     G        793      Description: Error log analysis indicates
                             a problem reported by the disk drive's self
                             monitoring function.
793-132                        Description: A disk drive hardware error
            D       793      occurred.

793-134                        Description: The adapter failed to
            D       B88      configure.
                  software

793-135     D        793      Description: The device failed to
                    B88      configure.

                  software

793-136                        Description: The certify operation
            D       793      failed.

793-137     D        793      Description: Unit attention condition has
                             occurred on the Send Diagnostic command.
                    B88

                    D50

795-201     D        795      Description: Config register test failure

795-202     D        795      Description: PROM check test failure

795-203     D        795      Description: Timer and IRQ test failure

795-204     D        795      Description: Adapter RAM check failure

795-205     D        795      Description: ASIC test failure

795-206     D        795      Description: High memory (ISA) test
                             failure
795-207     D        795      Description: RAM check via DMA test
                             failure
795-208     D        795      Description: FORMAC register test failure

795-209     D        795      Description: PLC1 test failure
                    221

795-210     D        795      Description: PLC2 test failure

795-211     D        795      Description: FORMAC Ring_Op test failure

795-212     D        795      Description: Send long frame test failure

795-213     D        795      Description: Restricted Token Monitor test
                             failure
795-214     D        795      Description: Receive queue handling test
                             failure
795-215     D        795      Description: FORMAC loopback test failure

795-216     D        795      Description: FORMAC loopback with master
                             access test failure
795-217     D        795      Description: DMA measurement test failure

795-218     D        795      Description: Special test failure

795-219     D        795      Description: Bypass test failure

795-301     D        795      Description: PLC1 FDDI external wrap
                             failure
795-302     D        795      Description: PLC2 FDDI external wrap
                             failure
795-303     D        795      Description: Send long frame FDDI external
                             wrap failure
795-304     D        795      Description: FORMAC loopback external wrap
                             failure
795-700     D        795      Description: Error log analysis indicates
                             hardware failure
799-101     D        2C3      Description: External wrap test failed on
                             port 0
                    799

799-102     D        2C3      Description: External wrap test failed on
                             port 1
                    799

799-201     D        799      Description: Internal adapter test failed

                    227

799-202     D        799      Description: External wrap test failed on
                             port 0
                    227

799-203     D        799      Description: External wrap test failed on
                             port 1
                    227

799-204     D        2C3      Description: External wrap test failed on
                             port 0
                    799

799-205     D        2C3      Description: External wrap test failed on
                             port 1
                    799

799-206     D        2C3      Description: External wrap test failed on
                             port 0
                    799

                  software

799-207     D        2C3      Description: External wrap test failed on
                             port 1
                    799

                  software

799-301     D        799      Description: Internal adapter test failed

                    227

                  software

799-302     D        799      Description: External wrap test failed on
                             port 0
                    227

                  software

799-303     D        799      Description: External wrap test failed on
                             port 1
                    227

                  software

799-304     D        2C3      Description: External wrap test failed on
                             port 0
                    799

                  software

799-305     D        2C3      Description: External wrap test failed on
                             port 1
                    799

                  software

799-700     D        799      Description: Error log analysis indicates
                             a hardware problem
                  software

7C1-101     D        7C1      Description: Audio Subsystem failed

                  software

7C1-102     D        7C1      Description: CS4232 Failed

7C1-103     D        7C1      Description: Clock control failed

7C1-107     D        7C1      Description: SoundBlaster interface failed

7C1-108     D        7C1      Description: Loop back failed

7C1-109     D        7C1      Description: CODEC ID invalid

7C1-117     D        D97      Description: Internal speaker failed

801-101     C                 Description: The diagnostics did not
                             detect an installed resource.
   to                        Action: Ensure supplemental diskettes have
                             been read, if applicable, then use Chapter
801-102                      18. "MAP 0290: Missing Resource Problem
                             Resolution".
802-787     C        787      Description: The diagnostics did not
                             detect an installed resource.
                    D95

802-78C     C                 Description: A system bus problem exists.
                             Action: Use Chapter 11. "MAP 0080 System
                             Bus Problem Isolation".
802-xxx     C        xxx      Description: The diagnostics did not
                             detect an installed resource.

                             Note: To obtain the FFC substitute the last
                             three digits of the SRN for xxx. (The
                             substituted xxx is the FFC.)
803-xxx     D    Use the xxx  Description: An error occurred while
                             running the diagnostics.
See note           number    Action: Run nondisk-based diagnostics where
                             possible. If this SRN was generated from
n Action                     the nondisk-based diagnostic package, or it
                             is not possible to use the nondisk-based
column.)                     package, go to Chapter 15. "MAP 0250:
                             Unexpected System Halts During
                             Diagnostics". If the problem occurs only
                             from disk-or server-based diagnostics,
                             suspect a software problem.

                             Notes:

                                    1. If your 803-xxx SRN is listed in
                                       this section, use the procedure
                                       for that SRN instead of this one.

                                    2. If the xxx FFC is not listed in
                                       the FFC list, Use MAP 1540 to
                                       determine the failing FRU.


804-111     D        804      Description: Unable to reserve device.

                    B88

804-112     D        804      Description: Unable to do configuration.

                    B88

804-113     D        804      Description: Unable to open the device
                             driver.
                    B88

804-121     D        804      Description: The CD-ROM drive indicates an
                             error.
804-122     D        804      Description: The CD-ROM drive indicates an
                             error.
804-123     D        804      Description: The CD-ROM drive indicates an
                             error.
804-125     D        804      Description: The CD-ROM drive indicates an
                             error.
                    B88

804-126     D        804      Description: The CD-ROM drive indicates an
                             error.
804-127     D        804      Description: The CD-ROM drive indicates an
                             error.
804-128     D        804      Description: The CD-ROM drive indicates an
                             error.
804-129     D        804      Description: The CD-ROM drive indicates an
                             error.
804-150     D       Media     Description: A media error was detected.

                    804

804-151     D        804      Description: A command timeout was
                             detected.
                    B88

804-152     D        804      Description: A command reservation
                             conflict was detected.
804-162     D        804      Description: The CD-ROM drive indicates an
                             error.
804-171     D        804      Description: Unable to reserve device.

804-172     D        804      Description: Unable to do configuration.

804-173     D        804      Description: Unable to open device driver.

804-175     D        804      Description: The CD-ROM drive indicates an
                             error.
804-198     D        804      Description: Undefined error detected.

                    B88

804-199     D        804      Description: Undefined error detected.

804-211     D        804      Description: The LED test failed.

804-281     D        804      Description: No tone during audio test.

804-301     G        804      Description: Errors found during ELA.

804-302     G        804      Description: Errors found during ELA.

                    B88

804-xxx     H      Use the    Description: An unexpected halt occurred
                             while running the diagnostics.
                    xxx
                             Note: If your 804-xxx SRN is listed in this
                   number    section, use the procedure for that SRN
                             instead of this one.
                             Action: Use Chapter 15. "MAP 0250:
                             Unexpected System Halts During
                             Diagnostics".
805-110     G        D67      Description: Error log analysis indicates
                             a machine check due to uncorrectable memory
                             error.
                             Action: Use Chapter 14. "MAP 0240: Memory
                             Problem Resolution".
805-111     G        D83      Description: Error log analysis indicates
                             a machine check due to uncorrectable memory
                             error.
                             Action: Use Chapter 14. "MAP 0240: Memory
                             Problem Resolution".
805-120     G        D68      Description: Error log analysis indicates
                             a machine check due to uncorrectable memory
                             error.
                             Action: Use Chapter 14. "MAP 0240: Memory
                             Problem Resolution".
805-121     G        D84      Description: Error log analysis indicates
                             a machine check due to uncorrectable memory
                             error.
                             Action: Use Chapter 14. "MAP 0240: Memory
                             Problem Resolution".
805-130     G        D69      Description: Error log analysis indicates
                             a machine check due to uncorrectable memory
                             error.
                             Action: Use Chapter 14. "MAP 0240: Memory
                             Problem Resolution".
805-131     G        D85      Description: Error log analysis indicates
                             a machine check due to uncorrectable memory
                             error.
                             Action: Use Chapter 14. "MAP 0240: Memory
                             Problem Resolution".
805-140     G        D70      Description: Error log analysis indicates
                             a machine check due to uncorrectable memory
                             error.
                             Action: Use Chapter 14. "MAP 0240: Memory
                             Problem Resolution".
805-141     G        D86      Description: Error log analysis indicates
                             a machine check due to uncorrectable memory
                             error.
                             Action: Use Chapter 14. "MAP 0240: Memory
                             Problem Resolution".
805-150     G        E11      Description: Error log analysis indicates
                             a machine check due to uncorrectable memory
                             error.
                             Action: Use Chapter 14. "MAP 0240: Memory
                             Problem Resolution".
805-151     G        E14      Description: Error log analysis indicates
                             a machine check due to uncorrectable memory
                             error.
                             Action: Use Chapter 14. "MAP 0240: Memory
                             Problem Resolution".
805-210     G        D71      Description: Error log analysis indicates
                             a machine check due to uncorrectable memory
                             error.
                             Action: Use Chapter 14. "MAP 0240: Memory
                             Problem Resolution".
805-211     G        D87      Description: Error log analysis indicates
                             a machine check due to uncorrectable memory
                             error.
                             Action: Use Chapter 14. "MAP 0240: Memory
                             Problem Resolution".
805-220     G        D72      Description: Error log analysis indicates
                             a machine check due to uncorrectable memory
                             error.
                             Action: Use Chapter 14. "MAP 0240: Memory
                             Problem Resolution".
805-221     G        D88      Description: Error log analysis indicates
                             a machine check due to uncorrectable memory
                             error.
                             Action: Use Chapter 14. "MAP 0240: Memory
                             Problem Resolution".
805-230     G        D73      Description: Error log analysis indicates
                             a machine check due to uncorrectable memory
                             error.
                             Action: Use Chapter 14. "MAP 0240: Memory
                             Problem Resolution".
805-231     G        D89      Description: Error log analysis indicates
                             a machine check due to uncorrectable memory
                             error.
                             Action: Use Chapter 14. "MAP 0240: Memory
                             Problem Resolution".
805-240     G        D74      Description: Error log analysis indicates
                             a machine check due to uncorrectable memory
                             error.
                             Action: Use Chapter 14. "MAP 0240: Memory
                             Problem Resolution".
805-241     G        D90      Description: Error log analysis indicates
                             a machine check due to uncorrectable memory
                             error.
                             Action: Use Chapter 14. "MAP 0240: Memory
                             Problem Resolution".
805-250     G        E12      Description: Error log analysis indicates
                             a machine check due to uncorrectable memory
                             error.
                             Action: Use Chapter 14. "MAP 0240: Memory
                             Problem Resolution".
805-251     G        E15      Description: Error log analysis indicates
                             a machine check due to uncorrectable memory
                             error.
                             Action: Use Chapter 14. "MAP 0240: Memory
                             Problem Resolution".
805-310     G        D75      Description: Error log analysis indicates
                             a machine check due to uncorrectable memory
                             error.
                             Action: Use Chapter 14. "MAP 0240: Memory
                             Problem Resolution".
805-311     G        D91      Description: Error log analysis indicates
                             a machine check due to uncorrectable memory
                             error.
                             Action: Use Chapter 14. "MAP 0240: Memory
                             Problem Resolution".
805-320     G        D76      Description: Error log analysis indicates
                             a machine check due to uncorrectable memory
                             error.
                             Action: Use Chapter 14. "MAP 0240: Memory
                             Problem Resolution".
805-321     G        D92      Description: Error log analysis indicates
                             a machine check due to uncorrectable memory
                             error.
                             Action: Use Chapter 14. "MAP 0240: Memory
                             Problem Resolution".
805-331     G        D93      Description: Error log analysis indicates
                             a machine check due to uncorrectable memory
                             error.
                             Action: Use Chapter 14. "MAP 0240: Memory
                             Problem Resolution".
805-340     G        D78      Description: Error log analysis indicates
                             a machine check due to uncorrectable memory
                             error.
                             Action: Use Chapter 14. "MAP 0240: Memory
                             Problem Resolution".
805-341     G        D94      Description: Error log analysis indicates
                             a machine check due to uncorrectable memory
                             error.
                             Action: Use Chapter 14. "MAP 0240: Memory
                             Problem Resolution".
805-350     G        E13      Description: Error log analysis indicates
                             a machine check due to uncorrectable memory
                             error.
                             Action: Use Chapter 14. "MAP 0240: Memory
                             Problem Resolution".
805-351     G        E16      Description: Error log analysis indicates
                             a machine check due to uncorrectable memory
                             error.
                             Action: Use Chapter 14. "MAP 0240: Memory
                             Problem Resolution".
805-600     G                 Description: Error log analysis indicates
                             a machine check due to uncorrectable memory
                             error or unsupported memory.
                             Action: Examine the memory modules and
                             determine if they are supported types. If
                             the modules are supported, then replace the
                             appropriate memory module(s). Use Chapter
                             14. "MAP 0240: Memory Problem Resolution".

805-601     G        210      Description: Error log analysis indicates
                             a machine check due to CPU internal cache
                             error.
805-602     G        214      Description: Error log analysis indicates
                             a machine check due to CPU address/data bus
                    D01      parity error.

805-603     G        210      Description: Error log analysis indicates
                             a machine check due to CPU bus transfer
                    214      error.

                    D01

805-604     G        210      Description: Error log analysis indicates
                             a machine check due to CPU address/data bus
                    D01      parity error.

805-605     G        210      Description: Error log analysis indicates
                             a machine check due to CPU bus transfer
                             error.
805-606     G        214      Description: Error log analysis indicates
                             a machine check due to memory controller
                             internal error.
805-607     G        210      Description: Error log analysis indicates
                             a machine check due to memory address
                    214      error.

805-608     G        214      Description: Error log analysis indicates
                             a machine check due to a Flash ROM error.
                    217

805-609     G        D01      Description: Error log analysis indicates
                             a machine check due to a L2 parity error.
805-610     G                 Description: Error log analysis indicates
                             a machine check due to ISA device error,
                             but the device could not be identified.
                             Action: Run diagnostics on the ISA devices.

805-611     G                 Description: Error log analysis indicates
                             a machine check due to EISA/ISA bus time
                             out error, but the device could not be
                             identified.
                             Action: Run diagnostics on the ISA devices.
                             If multiple devices fail, use FFC 295.
805-612     G        214      Description: Error log analysis indicates
                             a machine check due to an Illegal L2
                             copyback operation.
805-616     G     software    Description: Error log analysis indicates
                             a machine check due to software.
805-617     G                 Description: Error log analysis indicates
                             a machine check of unknown origin.
                             Action: If the problem is persistent, use
                             MAP 1540.
805-618     G                 Description: Error log analysis indicates
                             multiple instances of machine check of
                             unknown origin.
                             Action: If the problem is persistent, use
                             MAP 1540.
805-619     G        221      Description: Error log analysis indicates
                             a machine check due to an unidentified
                             source on the I/O subsystem. Action: Use
                             Chapter 12. "MAP 0210: General Problem
                             Resolution".
805-621     G        292      Description: Error log analysis indicates
                             a machine check due to Integrated PCI
                             device does not respond.
805-622     G        293      Description: Error log analysis indicates
                             a machine check due to Integrated PCI
                             device does not respond.
805-623     G        294      Description: Error log analysis indicates
                             a machine check due to Integrated PCI
                             device does not respond.
805-624     G        295      Description: Error log analysis indicates
                             a machine check due to Integrated PCI
                             device does not respond.
805-625     G        868      Description: Error log analysis indicates
                             a machine check due to Integrated PCI
                             device does not respond.
805-631     G        292      Description: Error log analysis indicates
                             a machine check due to Internal error from
                             PCI device.
805-632     G        293      Description: Error log analysis indicates
                             a machine check due to Internal error from
                             PCI device.
805-633     G        294      Description: Error log analysis indicates
                             a machine check due to Internal error from
                             PCI device.
805-634     G        295      Description: Error log analysis indicates
                             a machine check due to Internal error from
                             PCI device.
805-635     G        868      Description: Error log analysis indicates
                             a machine check due to Internal error from
                             PCI device.
805-640     G        2E8      Description: Error log analysis indicates
                             a machine check due to a system bus error.
                    214

805-641     G        2E8      Description: Error log analysis indicates
                             a machine check due to a processor bus
                    210      error.

805-642     G        2E8      Description: Error log analysis indicates
                             a machine check due to a directory parity
                             error.
805-643     G        2E8      Description: Error log analysis indicates
                             a machine check due to a cache paradox.
805-644     G        2E8      Description: Error log analysis indicates
                             a machine check due to an internal error.
805-645     G        2E8      Description: Error log analysis indicates
                             a machine check due to a detected L2 hit
                             signal.
805-646     G        2E8      Description: Error log analysis indicates
                             a machine check due to an address/data bus
                    214      parity error.

805-649     G     software    Description: Error log analysis indicates
                             a machine check due to a disabled I/O
                             address space.
                             Action: Run Standalone Diagnostics on all
                             devices. Use any SRN reported. If no other
                             SRN is reported, suspect a software
                             problem.
805-801     G        166      Description: Slow fan or defective thermal
                             sensor.
                    221      Action: 1) Check spacing around system
                             enclosure, 2) check for obstructions to
                             cooling air flow, 3) check that all fans
                             can rotate freely, and spin with power
                             applied. If reasons 1, 2 and 3 can be ruled
                             out, then replace the listed FRUs.
805-802     G        152      Description: Over/Under voltage condition.

                    210      Action: Check AC line voltage per the Power
                             MAP in your service guide. If the AC line
                             voltage is correct replace the listed FRUs.

805-803     G        2E1      Description: System shutdown due to
                             non-critical over temperature condition.
                    210      Action: 1) check for obstructions to
                             cooling air flow, 2) check for accumulated
                             dust on the CPU and planar. If reasons 1
                             and 2 can be ruled out, then replace the
                             listed FRUs.
805-804     G        166      Description: System shutdown due to
                             critical over temperature condition.
                    2E1      Action: Check to ensure fans are connected.
                             If fans are connected, then replace the
                    152      listed FRUs.

805-805     G        152      Description: System shutdown due to loss
                             of AC power.
                             Action: Check the voltage range switch, if
                             present, on the power supply and ensure
                             that it is set to match the AC input
                             voltage. If the range switch is set
                             correctly or is not present refer to "MAP
                             1520: Power" in the Service Guide for your
                             system.
805-807     G        166      Description: System shutdown due to an
                             inoperative fan.
                             Action: Check to ensure fans are connected.
                             If fans are connected replace the listed
                             FRU.
805-811     D        166      Description: Slow fan or defective thermal
                             sensor.
                             Action:

                               1. Check spacing around system enclosure

                               2. Check for obstructions to cooling air
                                  flow

                               3. Check that all fans rotate freely, and
                                  spin when power is applied.

                             If reasons 1, 2, and 3 can be ruled out,
                             then replace the listed FRUs.
805-812     D        152      Description: Over/Under voltage condition.

                    210      Action: Check the AC line voltage per the
                             Power MAP in your service guide. If the AC
                             line voltage is correct replace the listed
                             FRUs.
805-813     D        2E1      Description: System shutdown due to
                             non-critical over temperature condition.
                    210      Action:

                               1. Check for obstructions to cooling air
                                  flow.

                               2. Check for accumulated dust on the CPU
                                  and planar.

                             If reasons 1 and 2 can be ruled out, then
                             replace the listed FRUs.
806-001     D        806      GXT800P Graphics Adapter
  thru
806-017
806-018     D        806      GXT800P Graphics Adapter
                             Monitor/Display Cable
806-100     D        806      Description: GXT800P Graphics Adapter

806-505     D        806      Description: GXT800P Graphics Adapter
                             GXT800P Base Memory in slot 0, 1, 2, 3, or
                    298      4

806-515     D        806      Description: GXT800P Graphics Adapter
                             GXT800P Base and Texture Memory in slot 0,
                    297      1, 2, 3, or 4

806-619     G        221      Description: Error log analysis indicates
                             a machine check due to an unidentified
                             source on the I/O subsystem.
806-700     D        298      GXT800P Base Memory in slot 0

806-701     D        298      GXT800P Base Memory in slot 1

806-702     D        298      GXT800P Base Memory in slot 2

806-703     D        298      GXT800P Base Memory in slot 3

806-704     D        298      GXT800P Base Memory in slot 4

806-710     D        297      GXT800P Base and Texture Memory in slot 0

806-711     D        297      GXT800P Base and Texture Memory in slot 1

806-712     D        297      GXT800P Base and Texture Memory in slot 2

806-713     D        297      GXT800P Base and Texture Memory in slot 3

806-714     D        297      GXT800P Base and Texture Memory in slot 4

806-e00     D        298      GXT800P Base Memory in slot 0

806-e01     D        298      GXT800P Base Memory in slot 1

806-e02     D        298      GXT800P Base Memory in slot 2

806-e03     D        298      GXT800P Base Memory in slot 3

806-e04     D        298      GXT800P Base Memory in slot 4

806-e10     D        297      GXT800P Base and Texture Memory in slot 0

806-e11     D        297      GXT800P Base and Texture Memory in slot 1

806-e12     D        297      GXT800P Base and Texture Memory in slot 2

806-e13     D        297      GXT800P Base and Texture Memory in slot 3

806-e14     D        297      GXT800P Base and Texture Memory in slot 4

807-201     D        199      Description: Device configuration error

                    891

807-202     D        199      Description: Enclosure failed to open

                    891

807-203     D        199      Description: Enclosure failed to return
                             inquiry data
                    891

807-204     D        152      Description: Redundant power supply or fan
                             failure
                    166

807-205     D        152      Description: Redundant power supply or fan
                             failure
                    166

814-112     D        814      Description: The NVRAM test failed.

814-113     D        221      Description: The VPD test failed.

814-114     D        814      Description: I/O Card NVRAM test failed.

815-100     D        815      Description: The floating-point processor
                             test failed.
815-101     D        815      Description: Floating point processor
                             failed.
815-102     D        815      Description: Floating point processor
                             failed.
815-200     D        815      Description: Floating point processor
                             failed.
                    7C1

816-140     D        165      Description: The four-digit display test
                             failed.
                    816

817-123     D        817      Description: The I/O planar time-of-day
                             clock test failed.
817-124     D        817      Description: Time of day RAM test failed.

817-210     D        817      Description: The time-of-day clock is at
                             POR.
817-211     D        817      Description: Time of day POR test failed.

                    169

817-212     D        151      Description: The battery is low.

                    816

817-213     D        817      Description: The real-time clock is not
                             running.
817-215     D        817      Description: Time of day clock not running
                             test failed.
817-217     D        817      Description: Time of day clock not
                             running.
                    169

821-111     D        821      Description: Unexpected results from the
                             test.
                    B31

821-220     D        B10      Description: Keyboard adapter fuse failed.

                    821

821-221     D        821      Description: The keyboard adapter test
                             failed.
821-230     D        221      Description: Software error caused by
                             hardware failure.
821-240     G        821      Description: The error log analysis
                             indicates hardware failure.
821-241     G        221      Description: The error log analysis
                             indicates hardware failure.
821-242     G        921      Description: The error log analysis
                             indicates hardware failure.
                    821

821-243     G        922      Description: The error log analysis
                             indicates hardware failure.
                    821

821-244     G        923      Description: The error log analysis
                             indicates hardware failure.
                    821

821-310     D        821      Description: Standard Keyboard Adapter
   to                        failed.
821-331
821-332     D        821      Description: Cannot open device.

                  software

821-333     D        821      Description: Keyboard/tablet adapter
                             failed.
   to

821-334
821-921     D        921      Description: The keyboard adapter control
                             logic failed.
                    821

821-922     D        922      Description: The keyboard adapter control
                             logic failed.
                    821

821-923     D        923      Description: The keyboard adapter control
                             logic failed.
                    821

823-111     D        823      Description: Standard Mouse adapter
                             failed.
   to               925

823-112
823-113     D        B10      Description: The mouse adapter fuse
                             failed.
                    823

823-121     D        823      Description: Built-In mouse adapter
                             problems.
   to

823-122
823-130     D        221      Description: Software error caused by
                             hardware failure.
823-131     D        823      Description: Unable to put mouse adapter
                             into nonblock mode.
                    925

823-132     D        823      Description: Built-In mouse adapter
                             problem.
   to

823-133
823-134     D        823      Description: Cannot open device.

                  software

823-140     G        823      Description: The error log analysis
                             indicates hardware failure.
823-141     D        823      Description: Unable to place mouse adapter
                             in block mode.
                    925

823-142     D        823      Description: Unable to place mouse adapter
                             in block mode.
823-220     D        B10      Description: The mouse adapter fuse
                             failed.
                    823

824-220                       Description: The tablet adapter fuse
            D       B10      failed.
                    824

824-331                       Description: An unexpected error occurred.
            D       824
                    227

824-332                       Description: The enable/disable device
            D       824      test failed.
                    227      Note:Ensure that the wrap plug was not
                             attached when the test was run. If the wrap
                             plug was attached, remove it, and rerun the
                             test.
824-333                       Description: The internal wrap test
            D       824      failed.

824-334                       Description: The tablet adapter fuse
            D       B10      failed.
                    824

824-441                       Description: An unexpected error occurred.
            D       824

824-442                       Description: The wrap test failed.
            D       824

824-450              227      Description: Software error caused by
            D                hardware failure.

824-461              227      Description: The error log analysis
            G                indicates a hardware failure.

824-511                       Description: An unexpected error occurred.
            D       824

824-512                       Description: Tablet adapter reset test
            D       824      failed.

824-522                       Description: Adapter fuse failure.
            D       B10
                    824

824-523                       Description: Device cannot be configured.
            D       824

824-524                       Description: Cannot open device.
            D       824
                  software

826-111     D        221      Description: Cannot run the test because
                             the device driver detected a hardware
                             error.
826-112     D        221      Description: Unable to determine the type
                             of adapter from the VPD.
826-113     D        826      Description: The VPD verification test
                             failed.
826-114     D        826      Description: The register verification
                             test failed.
826-121     D        221      Description: Cannot run the test because
                             the device driver detected a hardware
                             error.
826-122     D        221      Description: The data-wrap communications
                             test failed.
826-123     D        221      Description: The modem control line test
                             failed.
826-131     D        221      Description: Cannot run the test because
                             the device driver detected a hardware
                             error.
826-132     D        221      Description: The data wrap communications
                             test failed.
826-133     D        221      Description: The modem control line test
                             failed.
826-161     D        252      Description: Cannot run the test because
                             the device driver detected a hardware
                             error.
826-162     D        252      Description: The data wrap communications
                             test failed.
826-163     D        252      Description: The modem control line test
                             failed.
826-171     D        259      Description: Cannot run the test because
                             the device driver detected a hardware
                             error.
826-172     D        259      Description: The data wrap communications
                             test failed.
826-173     D        259      Description: The modem control line test
                             failed.
826-181     D        261      Description: Cannot run the test because
                             the device driver detected a hardware
                             error.
826-182     D        261      Description: The data wrap communications
                             test failed.
826-183     D        261      Description: The modem control line test
                             failed.
826-271     D        826      Description: Cannot run the test because
                             the device driver detected a hardware
                    259      error.

826-272     D        826      Description: The data wrap communications
                             test failed.
                    259

826-273     D        826      Description: The modem control line test
                             failed.
                    259

826-281     D        826      Description: Cannot run the test because
                             the device driver detected a hardware
                    259      error.

826-282     D        826      Description: The data wrap communications
                             test failed.
                    259

826-283     D        826      Description: The modem control line test
                             failed.
                    259

826-321     D        826      Description: Cannot run the test because
                             the device driver detected a hardware
                             error.
826-322     D        826      Description: The data wrap communications
                             test failed.
826-323     D        826      Description: The modem control line test
                             failed.
826-331     D        826      Description: Cannot run the test because
                             the device driver detected a hardware
                             error.
826-332     D        826      Description: The data wrap communications
                             test failed.
826-333     D        826      Description: The modem control line test
                             failed.
826-371     D        826      Description: Cannot run the test because
                             the device driver detected a hardware
                             error.
826-372     D        826      Description: The data wrap communications
                             test failed.
826-373     D        826      Description: The modem control line test
                             failed.
826-381     D        826      Description: Could not do the test because
                             the device driver detected a hardware
                             error.
826-382     D        826      Description: The data wrap communication
                             test failed.
826-383     D        826      Description: The modem control line test
                             failed.
826-481     D        D56      Description: Could not do the test because
                             the device driver detected a hardware
                             error.
826-482     D        D56      Description: The data wrap communication
                             test failed.
826-483     D        D56      Description: The modem control line test
                             failed.
826-581     D        826      Description: Could not do the test because
                             the device driver detected a hardware
                    D56      error.

826-582     D        826      Description: The data wrap communication
                             test failed.
                    D56

826-583     D        826      Description: The modem control line test
                             failed.
                    D56

826-901     D     software    Description: An unexpected error occurred
                             that can be attributed to software or
   to               826      hardware.
826-920                      Action: Run diagnostics from a source other
                             than from the disk or a network. If the
                             same error occurs or if the original SRN
                             was not obtained from disk or a network
                             based diagnostics, use Chapter 12. "MAP
                             0210: General Problem Resolution" with a
                             FFC of 826; otherwise, suspect a software
                             problem.
826-921     D        826      Description: The adapter failed to
                             configure
                  software

826-922     D     software    Description: An unexpected error occurred
                             that can be attributed to software or
   to               826      hardware.
826-924                      Action: Run diagnostics from a source other
                             than from the disk or a network. If the
                             same error occurs or if the original SRN
                             was not obtained from disk or a network
                             based diagnostics, use Chapter 12. "MAP
                             0210: General Problem Resolution" with a
                             FFC of 826; otherwise, suspect a software
                             problem.
826-925     D        826      Description: The adapter failed to
                             configure
                  software

826-926     D     software    Description: An unexpected error occurred
                             that can be attributed to software or
   to               826      hardware.
826-943                      Action: Run diagnostics from a source other
                             than from the disk or a network. If the
                             same error occurs or if the original SRN
                             was not obtained from disk or a network
                             based diagnostics, use Chapter 12. "MAP
                             0210: General Problem Resolution" with a
                             FFC of 826; otherwise, suspect a software
                             problem.
827-112     D        221      Description: The parallel port data
                             register write/read test failed.
827-121     D        827      Description: Cannot run the test because
                             the device driver detected a hardware
                             error.
827-122     D        827      Description: The parallel port data
                             register write/read test failed.
827-123     D        827      Description: The parallel port control
                             register write/read test failed.
827-124     D        827      Description: The parallel port data
                             register read test failed.
827-125     D        827      Description: The parallel port control
                             register read test failed.
827-126     D        827      Description: The parallel port control
                             register read test failed.
827-131     D        827      Description: Cannot run the test because
                             the device driver detected a hardware
                             error.
827-132     D        827      Description: The control port register
                             direction bit (write) test with BIDI
                             enabled failed.
827-133     D        827      Description: The control port register
                             direction bit (read) test with BIDI enabled
                             failed.

827-141      D        827      Description: Cannot run the test because
                              the device driver detected a hardware
                              error.
827-142      D        827      Description: The parallel port control
                              register write/read test with BIDI
                              enabled failed.
827-151      D        221      Description: Cannot run the test because
                              the device driver detected a hardware
                              error.
827-152      D        827      Description: The parallel port status
                              register read test failed.
827-161      D        827      Description: Cannot run the test because
                              the device driver detected a hardware
                              error.
827-162      D        221      Description: The parallel port interrupt
                              test failed.
827-163      D        221      Description: The parallel port interrupt
                              test failed.
827-201      D        827      Description: The extend control register
                              of the parallel port failed a read/write
                              test.
827-202      D        827      Description: Input/output to the FIFO
                              (without interrupts) failed.
827-203      D        827      Description: Input/output to the FIFO
                              (with interrupts) failed.
827-204      D        827      Description: Direct memory access to the
                              FIFO failed.
828-501      D        828      Description: The diskette adapter test
                              failed.
82C-102      D        82C      Description: Adapter test failed.

82C-104      D        82C      Description: Display test failed.

                      725

830-111      D        830      Description: Could not do the test
                              because the device driver detected a
                      227     hardware error.

830-114      D        830      Description: The register verification
                              test failed.
830-121      D        830      Description: Could not do the test
                              because the device driver detected a
                      227     hardware problem.

830-122      D        830      Description: The data wrap communication
                              test failed.
                      227

830-123      D        830      Description: The modem control line test
                              failed.
                      227

830-124      D        830      Description: The memory test failed.

830-151      D        B54      Description: Could not do the test
                              because the device driver detected a
                      830     hardware error.

830-152      D        B54      Description: The data wrap communication
                              test failed.
                      830

830-153      D        D54      Description: The modem control line test
                              failed.
                      830

830-171      D        259      Description: Could not run the test
                              because the device driver detected a
                              hardware error.
830-172      D        259       The data wrap communication test
                              failed.
830-173      D        259      Description: The modem control line test
                              failed.
830-181      D        261      Description: Could not do the test
                              because the device driver detected a
                              hardware error.
830-182      D        261      Description: The data wrap communication
                              test failed.
830-183      D        261      Description: Interposer Wrap test
                              failed.
830-251      D        830      Description: Could not perform because
                              the device driver detected a hardware
                      D57     error.

830-252      D        830      Description: The data wrap communication
                              test failed.
                      B54

830-253      D        830      Description: The modem control line test
                              failed.
                      B54

830-271      D        830      Description: Could not perform because
                              the device driver detected a hardware
                      B54     error.

830-272      D        830      Description: The data wrap communication
                              test failed.
                      B54

830-273      D        830      Description: The modem control line test
                              failed
                      B54

830-281      D        830      Could not perform the test because the
                              device driver detected a hardware error.
                      D57

830-282      D        830      Description: The data wrap communication
                              test failed.
                      B54

830-283      D        830      Description: The modem control line test
                              failed.
                      B54

830-481      D        B54      Description: Could not do the test
                              because the device driver detected a
                              hardware error.
830-482      D        B54      Description: The data wrap communication
                              test failed.
830-483      D        B54      Description: Async Cable Wrap Test
                              failed.
830-901      D      software   Description: An unexpected error
                              occurred that can be attributed to
   to                 830     software or hardware.
830-920                       Action: Run diagnostics from a source
                              other than from the disk or a network. If
                              the same error occurs or if the original
                              SRN was not obtained from disk or a
                              network based diagnostics, use Chapter
                              12. "MAP 0210: General Problem
                              Resolution" with a FFC of 830; otherwise,
                              suspect a software problem.
830-921      D        830      Description: The adapter failed to
                              configure
                   software

830-922      D      software   Description: An unexpected error
                              occurred that can be attributed to
   to                 830     software or hardware.
830-924                       Action: Run diagnostics from a source
                              other than from the disk or a network. If
                              the same error occurs or if the original
                              SRN was not obtained from disk or a
                              network based diagnostics, use Chapter
                              12. "MAP 0210: General Problem
                              Resolution" with a FFC of 830; otherwise,
                              suspect a software problem.
830-925      D        830      Description: The adapter failed to
                              configure
                   software

830-926      D      software   Description: An unexpected error
                              occurred that can be attributed to
   to                 830     software or hardware.
830-943                       Action: Run diagnostics from a source
                              other than from the disk or a network. If
                              the same error occurs or if the original
                              SRN was not obtained from disk or a
                              network based diagnostics, use Chapter
                              12. "MAP 0210: General Problem
                              Resolution" with a FFC of 830; otherwise,
                              suspect a software problem.
831-111      D        221      Description: Cannot run the test because
                              the device driver detected a hardware
                              error.
831-112      D        221      Description: Unable to determine the
                              type of adapter from the VPD.
831-113      D        831      Description: The VPD verification test
                              failed.
831-114      D        831      Description: The register verification
                              test failed.
831-121      D        221      Description: Cannot run the test because
                              the device driver detected a hardware
                              error.
831-122      D        221      Description: The data wrap
                              communications test failed.
831-123      D        221      Description: The modem control line test
                              failed.
831-131      D        221      Description: Cannot run the test because
                              the device driver detected a hardware
                              error.
831-132      D        221      Description: The data wrap
                              communications test failed.
831-133      D        221      Description: The modem control line test
                              failed.
831-161      D        252      Description: Cannot run the test because
                              the device driver detected a hardware
                              error.
831-162      D        252      Description: The data wrap
                              communications test failed.
831-163      D        252      Description: The modem control line test
                              failed.
831-164      D        221      Description: Cannot run the test because
                              the device driver detected a hardware
                      252     error.

831-165      D        221      Description: The data wrap
                              communications test failed.
                      252

831-166      D        221      Description: The modem control line test
                              failed.
                      252

831-171      D        259      Description: Cannot run the test because
                              the device driver detected a hardware
                              error.
831-172      D        259      Description: The data wrap
                              communications test failed.
831-173      D        259      Description: The modem control line test
                              failed.
831-181      D        261      Description: Cannot run the test because
                              the device driver detected a hardware
                              error.
831-182      D        261      Description: The data wrap
                              communications test failed.
831-183      D        261      Description: The modem control line test
                              failed.
831-271      D        831      Description: Cannot run the test because
                              the device driver detected a hardware
                      259     error.

831-272      D        831      Description: The data wrap communication
                              test failed.
                      259

831-273      D        831      Description: The modem control line test
                              failed.
                      259

831-281      D        831      Description: Cannot run the test because
                              the device driver detected a hardware
                      259     error.

831-282      D        831      Description: The data wrap
                              communications test failed.
                      259

831-283      D        831      Description: The modem control line test
                              failed.
                      259

831-321      D        831      Description: Cannot run the test because
                              the device driver detected a hardware
                              error.
831-322      D        831      Description: The data wrap
                              communications test failed.
831-323      D        831      Description: The modem control line test
                              failed.
831-331      D        831      Description: Cannot run the test because
                              the device driver detected a hardware
                              error.
831-332      D        831      Description: The data wrap
                              communications test failed.
831-333      D        831      Description: The modem control line test
                              failed.
831-371      D        831      Description: Cannot run the test because
                              the device driver detected a hardware
                              error.
831-372      D        831      Description: The data wrap
                              communications test failed.
831-373      D        831      Description: The modem control line test
                              failed.
831-381      D        831      Description: Cannot run the test because
                              the device driver detected a hardware
                              error.
831-382      D        831      Description: The data wrap
                              communications test failed.
831-383      D        831      Description: The modem control line test
                              failed.
831-481      D        D56      Description: Could not do the test
                              because the device driver detected a
                              hardware error.
831-482      D        D56      Description: The data wrap communication
                              test failed.
831-483      D        D56      Description: The modem control line test
                              failed.
831-581      D        831      Description: Could not do the test
                              because the device driver detected a
                      D56     hardware error.

831-582      D        831      Description: The data wrap communication
                              test failed.
                      D56

831-583      D        831      Description: The modem control line test
                              failed.
                      D56

831-901      D      software   Description: An unexpected error
                              occurred that can be attributed to
   to                 831     software or hardware.
831-920                       Action: Run diagnostics from a source
                              other than from the disk or a network. If
                              the same error occurs or if the original
                              SRN was not obtained from disk or a
                              network based diagnostics, use Chapter
                              12. "MAP 0210: General Problem
                              Resolution" with a FFC of 831; otherwise,
                              suspect a software problem.
831-921      D        831      Description: The adapter failed to
                              configure
                   software

831-922      D      software   Description: An unexpected error
                              occurred that can be attributed to
   to                 831     software or hardware.
831-924                       Action: Run diagnostics from a source
                              other than from the disk or a network. If
                              the same error occurs or if the original
                              SRN was not obtained from disk or a
                              network based diagnostics, use Chapter
                              12. "MAP 0210: General Problem
                              Resolution" with a FFC of 831; otherwise,
                              suspect a software problem.
831-925      D        831      Description: The adapter failed to
                              configure
                   software

831-926      D      software   Description: An unexpected error
                              occurred that can be attributed to
   to                 831     software or hardware.
831-943                       Action: Run diagnostics from a source
                              other than from the disk or a network. If
                              the same error occurs or if the original
                              SRN was not obtained from disk or a
                              network based diagnostics, use Chapter
                              12. "MAP 0210: General Problem
                              Resolution" with a FFC of 831; otherwise,
                              suspect a software problem.
832-xxx      G        xxx      I/O Device Internal Error

                              Note: xxx represents the last 3 digits of
                              the SRN.
833-xxx      G        xxx      Description: PCI device address parity
                              error, PCI device data parity error, or
                      296     PCI device abort error. The diagnostics
                              screen indicates the actual error.
                      2C9
                              Note: xxx represents the last 3 digits of
                              the SRN.
836-101                         Description: Cannot run the test
             D        836     because the device driver detected a
                              hardware error.
836-111                         Description: Cannot run test because
             D        836     the device driver detected a hardware
                      227     error.

836-112                         Description: Unable to determine the
             D        836     type of adapter from the VPD.
                      227

836-113                         Description: The VPD verification test
             D        836     failed.

836-114                         Description: The register verification
             D        836     test failed.

836-115                         Description: The VPD verification test
             D        836     failed.

836-116                         Description: The 128-port controller
             D        B54     line test failed.
                      836

836-117      D        684      Description: Remote Async Node test
                              failed.
836-118                         Description: Remote async node test
             D        837     failed.

836-119                         Description: Sync line termination test
             F        836     failed.

836-151                         Description: Cannot run the test
             D        837     because the device driver detected a
                              hardware error.
836-152                         Description: The data wrap
             D        837     communications test failed.

836-153                         Description: The modem control line
             D        837     test failed.

836-154      D        684      Desciption: Cannot run the test because
                              the device driver detected a hardware
                      836     error.

836-155      D        684      Description: The data wrap
                              communications test failed.
                      836

                      152

836-161                         Description: Cannot run the test
             D        C22     because the device driver detected a
                              hardware error.
836-162                         Description: The data wrap
             D        C22     communications test failed.

836-163                         Description: The modem control line
             D        C22     test failed.

836-164                         Description: The data wrap
             D        D06     communication test failed.

836-171                         Description: Cannot run the test
             D        259     because the device driver detected a
                              hardware error.
836-172                         Description: The data wrap
             D        259     communications test failed.

836-173                         Description: The modem control line
             D        259     test failed.

836-174      D        263      Description: Cannot run the test because
                              the device driver detected a hardware
                              error while running the Printer/Terminal
                              cable wrap test.
836-175      D        263      Description: The data wrap
                              communications test failed while running
                              the Printer/Terminal cable wrap test.
836-181                         Description: Cannot run the test
             D        261     because the device driver detected a
                              hardware error.
836-182                         Description: The data wrap
             D        261     communications test failed.

836-183                         Description: The modem control line
             D        261     test failed.

836-251                         Description: Cannot run the test
             D        836     because the device driver detected a
                      837     hardware error.

836-252                         Description: The data wrap
             D        836     communications test failed.
                      837

836-253                         Description: The modem control line
             D        836     test failed.
                      837

836-254      D        836      Description: Cannot run the test because
                              the device driver detected a hardware
                      684     error while running the Remote Async Node
                              wrap test.
836-255      D        836      Description: The data wrap
                              communications test failed while running
                      684     the Remote Async Node wrap test.

836-271                         Description: Cannot run the test
             D        836     because the device driver detected a
                      837     hardware error.

836-272                         Description: The data wrap
             D        836     communications test failed.
                      837

836-273                         Description: The modem control line
             D        836     test failed.
                      837

836-274      D        836      Description: Cannot run the test because
                              the device driver detected a hardware
                      684     error while running the Printer/Terminal
                              cable wrap test.
836-275      D        836      Description: The data wrap
                              communications test failed while running
                      684     the Printer/Terminal cable wrap test.

836-281                         Description: Cannot run the test
             D        836     because the device driver detected a
                      837     hardware error.

836-282                         Description: The data wrap
             D        836     communication test failed.
                      837

836-283                         Description: The modem control line
             D        836     test failed.
                      837

836-481                         Description: Could not do the test
             D        D56     because the device driver detected a
                              hardware error.
836-482                         Description: The data wrap
             D        D56     communication test failed.

836-483                         Description: The modem control line
             D        D56     test failed.

836-901      D      software   Description: An unexpected error
                              occurred that can be attributed to
   to                 836     software or hardware.
836-920                       Action: Run diagnostics from a source
                              other than from the disk or a network. If
                              the same error occurs or if the original
                              SRN was not obtained from disk or a
                              network based diagnostics, use Chapter
                              12. "MAP 0210: General Problem
                              Resolution" with a FFC of 836; otherwise,
                              suspect a software problem.
836-921      D        836      Description: The adapter failed to
                              configure
                   software

836-922      D      software   Description: An unexpected error
                              occurred that can be attributed to
   to                 836     software or hardware.
836-924                       Action: Run diagnostics from a source
                              other than from the disk or a network. If
                              the same error occurs or if the original
                              SRN was not obtained from disk or a
                              network based diagnostics, use Chapter
                              12. "MAP 0210: General Problem
                              Resolution" with a FFC of 836; otherwise,
                              suspect a software problem.
836-925      D        836      Description: The adapter failed to
                              configure
                   software

836-926      D      software   Description: An unexpected error
                              occurred that can be attributed to
   to                 836     software or hardware.
836-943                       Action: Run diagnostics from a source
                              other than from the disk or a network. If
                              the same error occurs or if the original
                              SRN was not obtained from disk or a
                              network based diagnostics, use Chapter
                              12. "MAP 0210: General Problem
                              Resolution" with a FFC of 836; otherwise,
                              suspect a software problem.
840-212      D        840      Description: FIFO empty bit set.
                              Action: Go to Chapter 7. "MAP 0050: SCSI
                      221     Problems Isolation Procedure".

840-213      D        840      Description: FIFO empty bit clear.
                              Action: Go to Chapter 7. "MAP 0050: SCSI
                      221     Problems Isolation Procedure".

840-214      D        840      Description: FIFO full bit set.
                              Action: Go to Chapter 7. "MAP 0050: SCSI
                      221     Problems Isolation Procedure".

840-215      D        840      Description: FIFO full bit clear.
                              Action: Go to Chapter 7. "MAP 0050: SCSI
                      221     Problems Isolation Procedure".

840-216      D        840      Description: FIFO data miscompare.
                              Action: Go to Chapter 7. "MAP 0050: SCSI
                      221     Problems Isolation Procedure".

840-217      D        840      Description: SCSI FIFO data miscompare.
                              Action: Go to Chapter 7. "MAP 0050: SCSI
                      221     Problems Isolation Procedure".

840-218      D        840      Description: SCSI FIFO underflow.
                              Action: Go to Chapter 7. "MAP 0050: SCSI
                      221     Problems Isolation Procedure".

840-219      D        840      Description: SCSI parity error.
                              Action: Go to Chapter 7. "MAP 0050: SCSI
                      221     Problems Isolation Procedure".

840-220      D        840      Description: SCSI FIFO flags error.
                              Action: Go to Chapter 7. "MAP 0050: SCSI
                      221     Problems Isolation Procedure".

840-221      D        840      Description: Miscompare during the
                              write/read of the configuration register.
                      221
                              Action: Go to Chapter 7. "MAP 0050: SCSI
                              Problems Isolation Procedure".
840-222      D        840      Description: Error during the write/read
                              of the memory register.
                      221     Action: Go to Chapter 7. "MAP 0050: SCSI
                              Problems Isolation Procedure".
840-223      D        840      Description: Miscompare during the
                              write/read of the memory I/O register.
                      221     Action: Go to Chapter 7. "MAP 0050: SCSI
                              Problems Isolation Procedure".
840-224      D        840      Description: Error reading the PCI
                              configuration register.
                      221

840-225      D        840      Description: Adapter POST failed.

                      221

840-230      D        D50      Description: Arbitration test failed.
                              Action: Go to Chapter 7. "MAP 0050: SCSI
                      840     Problems Isolation Procedure"..

840-231      D        D50      Description: Function could not
                              complete.
                      840     Action: Go to Chapter 7. "MAP 0050: SCSI
                              Problems Isolation Procedure".
840-232      D        D50      Description: SCSI bus data miscompare.
                              Action: Go to Chapter 7. "MAP 0050: SCSI
                      840     Problems Isolation Procedure".

840-240      D        840      Description: No terminal power.
                              Action: Go to Chapter 7. "MAP 0050: SCSI
                      221     Problems Isolation Procedure".

840-301      D        840      Description: Configuration open failed
                              for parent bus.
                      D50

                   software

840-700      G        840      Description: Error log analysis
                              indicates a PCI SCSI adapter failure.
                   software

840-701      G        840      Description: Error log analysis
                              indicates a PCI SCSI adapter failure.
                   software

840-702      G        840      Description: Error log analysis
                              indicates a PCI SCSI adapter failure.
                   software

840-703      G        840      Description: Error log analysis
                              indicates a PCI SCSI adapter failure.
                   software

840-704      G        840      Description: Error log analysis
                              indicates a PCI SCSI adapter failure.
                   software

840-705      G        840      Description: Error log analysis
                              indicates a PCI SCSI adapter failure.
                   software

840-800      G        746      Description: Error log analysis
                              indicates a PCI SCSI adapter PTC failure.

                              Action: Go to Chapter 7. "MAP 0050: SCSI
                              Problems Isolation Procedure".
840-802      G        840      Description: Error log analysis
                              indicates a PCI SCSI bus failure.
                              Action: Go to Chapter 7. "MAP 0050: SCSI
                              Problems Isolation Procedure".
844-XXX      D        844      Description: A 7135 controller problem
 series                       is indicated.
                              Action: Use 7135 documentation.
845-XXX      D        845      Description: A 7135 DASD drawer problem
                              is indicated.
 series                       Action: Use 7135 documentation.
846-XXX      D        846      Description: A 7135 DASD drawer problem
                              is indicated.
 series                       Action: Use 7135 documentation.
868-110      D        221      Description: The adapter diagnostic
                              subcommand test failed.
868-130      D        279      Description: The adapter fuse test
                              failed.
868-140      D        868      Description: The wrap test failed.

868-150      D        868      Description: The BCR registers
                              write/read test failed.
868-160      D        868      Description: The POS registers
                              write/read test failed.
868-170      D        868      Description: The internal/external reset
                              test failed.
868-180      D        279      Description: The adapter command timed
                              out.
                      868
                              Note: Check the fuse before replacing.
868-190      D        221      Description: A software error was caused
                              by a hardware failure.
868-191      G        868      Description: Analysis of the error log
                              indicates a problem with the hardware.
868-192      G        221      Description: Analysis of the error log
                              indicates a problem with the hardware.
868-193      G        279      Description: Analysis of the error log
                              indicates a problem with the hardware.
868-194      G        868      Description: Analysis of the error log
                              indicates a problem with the hardware.
868-200      D        868      Description: ROM CRC error.

868-201      D        868      Description: Adapter RAM error.

868-202      D        868      Description: The control logic failed.

868-203      D        868      Description: The control logic failed.

868-204      D        868      Description: The control logic failed.

868-205      D        868      Description: The control logic failed.

868-206      D        868      Description: Diagnostics completed with
                              a previous error.
868-211      D        279      Description: The device failed to
                              configure.
                      868

                   software

868-212      D        221      Description: FIFO empty bit set.
                              Action: Go to Chapter 7. "MAP 0050: SCSI
                              Problems Isolation Procedure".
868-213      D        221      Description: FIFO empty bit clear.
                              Action: Go to Chapter 7. "MAP 0050: SCSI
                              Problems Isolation Procedure".
868-214      D        221      Description: FIFO full bit set.
                              Action: Go to Chapter 7. "MAP 0050: SCSI
                              Problems Isolation Procedure".
868-215      D        221      Description: FIFO full bit clear.
                              Action: Go to Chapter 7. "MAP 0050: SCSI
                              Problems Isolation Procedure".
868-216      D        221      Description: FIFO data miscompare.
                              Action: Go to Chapter 7. "MAP 0050: SCSI
                              Problems Isolation Procedure".
868-217      D        221      Description: SCSI FIFO data miscompare.
                              Action: Go to Chapter 7. "MAP 0050: SCSI
                              Problems Isolation Procedure".
868-218      D        221      Description: SCSI FIFO underflow.
                              Action: Go to Chapter 7. "MAP 0050: SCSI
                              Problems Isolation Procedure".
868-219      D        221      Description: SCSI parity error.
                              Action: Go to Chapter 7. "MAP 0050: SCSI
                              Problems Isolation Procedure".
868-220      D        221      Description: SCSI FIFO flags error.
                              Action: Go to Chapter 7. "MAP 0050: SCSI
                              Problems Isolation Procedure".
868-221      D        221      Description: Miscompare during the
                              write/read of the configuration register.

                              Action: Go to Chapter 7. "MAP 0050: SCSI
                              Problems Isolation Procedure".
868-222      D        221      Description: Error during the write/read
                              of the memory register.
                              Action: Go to Chapter 7. "MAP 0050: SCSI
                              Problems Isolation Procedure".
868-223      D        221      Description: Miscompare during the
                              write/read of the memory I/O register.
                              Action: Go to Chapter 7. "MAP 0050: SCSI
                              Problems Isolation Procedure".
868-224      D        221      Description: Error reading the PCI
                              configuration register.
                              Action: Use Chapter 12. "MAP 0210:
                              General Problem Resolution".
868-225      D        221      Description: POST failed.

868-230      D        D50      Description: Arbitration test failed.
                              Action: Go to Chapter 7. "MAP 0050: SCSI
                      868     Problems Isolation Procedure".

868-231      D        D50      Description: Function could not
                              complete.
                      868     Action: Go to Chapter 7. "MAP 0050: SCSI
                              Problems Isolation Procedure".
868-232      D        D50      Description: SCSI bus data miscompare.
                              Action: Go to Chapter 7. "MAP 0050: SCSI
                      868     Problems Isolation Procedure".

868-240      D        221      Description: No terminal power.
                              Action: Go to Chapter 7. "MAP 0050: SCSI
                              Problems Isolation Procedure".
868-301      D        868      Description: Configuration open failed
                              for parent bus.
                      D50

                   software

868-700      G        868      Description: Error log analysis
                              indicates a PCI SCSI adapter failure.
                   software

868-701      G        868      Description: Error log analysis
                              indicates a PCI SCSI adapter failure.
                   software

868-702      G        868      Description: Error log analysis
                              indicates a PCI SCSI adapter failure.
                   software

868-703      G        868      Description: Error log analysis
                              indicates a PCI SCSI adapter failure.
                   software

868-704      G        868      Description: Error log analysis
                              indicates a PCI SCSI adapter failure.
                   software

868-705      G        868      Description: Error log analysis
                              indicates a PCI SCSI adapter failure.
                   software

868-800      G        868      Description: Error log analysis
                              indicates a PCI SCSI adapter PTC failure.

                              Action: Go to Chapter 7. "MAP 0050: SCSI
                              Problems Isolation Procedure".
868-802      G        868      Description: Error log analysis
                              indicates a PCI SCSI bus failure.
                              Action: Go to Chapter 7. "MAP 0050: SCSI
                              Problems Isolation Procedure".
887-101      D        887      Description: POS register test failed.

887-102      D        887      Description: I/O register test failed.

887-103      D        887      Description: Local RAM test failed.

887-104      D        887      Description: Vital Product Data (VPD)
                              failed.
887-105      D        887      Description: LAN coprocessor internal
                              tests failed.
887-106      D        887      Description: Internal loopback test
                              failed.
887-107      D        887      Description: External loopback test
                              failed.
887-108      D        887      Description: External loopback test
                              failed.
887-109      D        887      Description: External loopback parity
                              tests failed.
887-110      D        887      Description: External loopback fairness
                              test failed.
887-111      D        887      Description: External loopback fairness
                              and parity tests failed.
887-112      D        887      Description: External loopback (twisted
                              pair) test failed.
887-113      D        887      Description: External loopback (twisted
                              pair) parity test failed.
887-114      D        887      Description: Ethernet loopback (twisted
                              pair) fairness test failed.
887-115      D        887      Description: External loopback (twisted
                              pair) fairness and parity tests failed.
887-116      D        887      Description: Twisted pair wrap data
                              failed ).
887-117      D        887      Description: Device configuration fails.

                   software

887-118      D        887      Description: Device driver indicates a
                              hardware problem.
887-120      D        887      Description: Device driver indicates a
                              hardware problem.
887-121      D        B08      Description: Ethernet transceiver test
                              failed.
887-122               B09      Description: Ethernet 10 Base-2
                              transceiver test failed.
887-123      D        887      Description: Internal loopback test
                              failed.
887-124      G        887      Description: Error log indicates a
                              hardware problem.
                   software

887-125      G        887      Description: Fuse test failed.

887-202      D        887      Description: Vital product data test
                              failed.
887-203      D        887      Description: Vital product data test
                              failed.
887-209      D        887      Description: RJ-45 converter test
                              failed.
887-304      D        887      Description: Coprocessor internal test
                              failed.
887-305      D        887      Description: Internal loopback test
                              failed.
887-306      D        887      Description: Internal loopback test
                              failed.
887-307      D        887      Description: External loopback test
                              failed.
887-319      D        887      Description: Device driver indicates a
                              hardware failure.
                   software

887-400      D        887      Description: Fuse test failed.

887-401      D        887      Description: Circuit breaker for
                              Ethernet test failed.
887-402      D        B09      Description: Ethernet 10 Base-2
                              transceiver test failed.
                      887

887-403      D        B08      Description: Ethernet 10 Base-T
                              transceiver test failed.
                      887

887-404      D        C29      Description: RJ-45 converter test
                              failed.
                      887

887-405      F      Ethernet   Description: Rerun diagnostics in
                              advanced mode for accurate problem
                    network   determination.
                      887

89c-111      D        89c      Description: Unable to reserve device.

                      B88

89c-112      D        89c      Description: Unable to do configuration.

                      B88

89c-113      D        89c      Description: Unable to open the device
                              driver.
                      B88

89c-121      D        89c      Description: The CD-ROM drive indicates
                              an error.
89c-122      D        89c      Description: The CD-ROM drive indicates
                              an error.
89c-123      D        89c      Description: The CD-ROM drive indicates
                              an error.
89c-125      D        89c      Description: The CD-ROM drive indicates
                              an error.
                      B88

89c-126      D        89c      Description: The CD-ROM drive indicates
                              an error.
89c-127      D        89c      Description: The CD-ROM drive indicates
                              an error.
89c-128      D        89c      Description: The CD-ROM drive indicates
                              an error.
89c-129      D        89c      Description: The CD-ROM drive indicates
                              an error.
89c-150      D       Media     Description: A media error was detected.

                      89c

89c-151      D        89c      Description: A command timeout was
                              detected.
                      D88

89c-152      D        89c      Description: A command reservation
                              conflict was detected.
89c-162      D        89c      Description: The CD-ROM drive indicates
                              an error.
89c-171      D        89c      Description: Unable to reserve device.

89c-172      D        89c      Description: Unable to do configuration.

89c-173      D        89c      Description: Unable to open device
                              driver.
89c-175      D        89c      Description: The CD-ROM drive indicates
                              an error.
89c-198      D        89c      Description: Undefined error detected.

                      B88

89c-199      D        89c      Description: Undefined error detected.

89c-211      D        89c      Description: The LED test failed.

89c-281      D        89c      Description: No tone during audio test.

89c-301      G        89c      Description: Errors found during ELA.

89c-302      G        89c      Description: Errors found during ELA.

                      B88