101-000   A                 Description: The system hung while
                           attempting to configure a device.
                           Action: Use MAP 1540.
101-185   A                 Description: A checkstop occurred.
                           Action: Use MAP 1540 in the system unit
                           service guide to isolate the cause.
101-517   A                 Description: The system unit failed to
                           IPL.
                           Action: Use MAP 1540.
                             Description: CD-ROM read problems after
101-518   A                boot.
                           Note:The boot record was read from the
                           CD-ROM disk. However, errors occurred when
                           trying to mount the CD-ROM file system.
                           This problem can be caused by SCSI device
                           addressing, SCSI terminator, open PTC, SCSI
                           cable, etc.
                           Action: Go to Chapter 7. "MAP 0050: SCSI
                           Problems Isolation Procedure"
                             Description: The configuration manager
101-521   A                detected an error.
   to                      Action: If you are running the diagnostics
101-538                    from a disk, try running the diagnostics
                           from a CD-ROM. If the diagnostics run
                           correctly from CD-ROM, the problem may be
                           damaged data on the disk. Contact your
                           software support facility. If a different
                           problem occurs when you run the diagnostics
                           from CD ROM, correct that problem. If you
                           were running from a CD ROM at first, or
                           have the same problem on CD ROM that you
                           had when running diagnostics from disk then
                           go to MAP 1540, in either the service guide
                           or the installation and service guide for
                           this system unit.
                             Description: Disk read problems occurred
101-544   A                after booting.
                           errors occurred when trying to open the
                           disk drive. This problem can be caused by
                           SCSI device addressing, SCSI terminator,
                           open PTC, SCSI cable, etc.
                           Action: Go to Chapter 7. "MAP 0050: SCSI
                           Problems Isolation Procedure"
                             Description: The system hung while
101-551   A                loading the software. This can be caused by
   to                      a hardware or software problem.
101-557                    Action: Run the diagnostics from CD-ROM.
                           Start at Chapter 4. "MAP 0020: Problem
                           Determination Procedure", Step 14. If the
                           diagnostics run correctly from CD-ROM, the
                           problem may be damaged disk data. Consider
                           having the customer contact Software
                           Support before reinstalling the operating
                           system on the disk. If you still get the
                           same SRN, go to MAP 1540 in either the
                           service guide or the installation and
                           service guide for this system unit.
                             Description: There is not enough memory
101-558   A                to execute diagnostics.
                           Action: There must be a minimum of 16MB of
                           installed memory. If the system has 16MB or
                           more of memory installed, suspect a problem
                           with a memory card.
101-559   A                 Description: The system halted while
                           software was loading. This problem may be
   to                      attributed to either hardware or software.
                           Action: Use the CD ROM based diagnostics if
101-599                    not yet used. If the same SRN is generated
                           from the CD ROM diagnostics, go to MAP 1540
                           in the system unit service guide for
                           problem isolation.

                           If the SRN is not generated when using the
                           CD ROM, suspect a problem with the system's
                           software.
          A        xxx       Description: The system hung while trying
101-711                   to configure an unknown resource.
   to                     Action: Run diagnostics from CD-ROM. Start
101-726                   at Chapter 4. "MAP 0020: Problem
                          Determination Procedure", Step 14. If you
                          still get the same SRN, refer to "Failing
                          Function Code List" and find the FFC that
                          matches the last three digits of the SRN.
                          Suspect the device adapter or device
                          itself. If more than one adapter or device
                          is installed, isolate the failing resource
                          by removing the adapters or devices one at
                          a time and checking if the system stops
                          with the same value in the three-digit
                          display.

                          Note: xxx corresponds to the last three
                          digits of the SRN.
                          The system hung while trying
101-727   A               to configure an asynchronous adapter.
                          Use MAP 1540 in the installation and service guide for this system unit.
                          Suspect a problem with one of the async adapters.
101-7C1   A      7C1      Description: The system unit halted while
                          configuring an audio subsystem.
101-888   A      210      Description: The system does not IPL.
                          Action: Use Chapter 16. "MAP 0260: System
                 227      Hangs During Resource Configuration".

                 E10

101-c32   D               The system hung while indicating that a direct-attached
                          display was selected as the console.
                           Go to MAP 1540 in either the service guide or the
                          installation and service guide for this system unit.
                          Suspect the graphics adapter being used for the display
                          console first.
101-c33   D                 Description: The system hung while
                           indicating that a TTY terminal is the
                           system console.
                           Action: Go to MAP 1540 in either the
                           service guide or the installation and
                           service guide for this system unit. Suspect
                           the graphics adapter being used for the
                           display console first.
101-xxx   A        xxx      Description: The system hung while
                           configuring a resource. The last three
                  227      digits identify the failing function code
                           for the resource being configured.
                           Action: Use Chapter 16. "MAP 0260: System
                           Hangs During Resource Configuration".
103-151   D        151      Description: The time-of-day battery
                           failed.
103-202   H                 Description: Unexpected interrupt.
   to                      Action: Go to MAP 1540 in either the
103-210                    service guide or the installation and
                           service guide for this system unit.
109-200   B                 Description: The system crashed while
                           being run by the customer.
                           Action: Use Chapter 4. "MAP 0020: Problem
                           Determination Procedure", and get a new
                           SRN.
110-101   C                 Description: The diagnostics did not
                           detect an installed resource.
                           Action: If this SRN appeared when running
                           concurrent diagnostics, then run concurrent
                           using the diag -a command, otherwise use
                           Chapter 18. "MAP 0290: Missing Resource
                           Problem Resolution".
110-908   D        908      Description: The system halted while
                           diagnostics were executing.
                  C33

                  C36

110-921   D                 Description: The system halted while
   to             xxx      diagnostics were executing.
110-926
                  812      Note: xxx corresponds to the last three
                           digits of the SRN.
110-935   D        935      Description: The system halted while
                           diagnostics were executing.
                  812

110-946   D        946      Description: The system halted while
                           diagnostics were executing.
                  221

110-xxx   D                 Description: The system halted while
                  xxx      diagnostics were executing.

                  221      Note: xxx corresponds to the last three
                           digits of the SRN. If your 110 SRN is not
                           listed below, use the 110-xxx procedure.
111-259   B                 Description: Cannot display readable
                           information on the terminal.
                           Action: Use Chapter 17. "MAP 0280: Boot
                           Problem Resolution" Entry 3.
111-725   B        725      Description: Cannot display readable
                           information on the display.

                           Note: Suspect the display adapter attached
                           to the console display.
                           Action: Use Chapter 17. "MAP 0280: Boot
                           Problem Resolution"
111-736   B        736      Description: The keyboard does not
                           respond.
                  821      Action: Use Chapter 17. "MAP 0280: Boot
                           Problem Resolution" Entry 1.
111-78C   B    PCI adapter  Description: I/O bus problem.
                           Action: Use Chapter 12. "MAP 0210: General
                  227      Problem Resolution".

                  E10      Note: PCI adapter refers to the adapters
                           you made note of when using Chapter 11.
                           "MAP 0080 System Bus Problem Isolation".
111-82C   B                 Description: Cannot display readable
                           information on the display.
                           Action: Go to Chapter 17. "MAP 0280: Boot
                           Problem Resolution" Entry 2.
111-922   B        922      Description: The keyboard does not
                           respond.
                  821      Action: Use Chapter 17. "MAP 0280: Boot
                           Problem Resolution" Entry 1.
111-923   B        923      Description: The keyboard does not
                           respond.
                  821      Action: Use Chapter 17. "MAP 0280: Boot
                           Problem Resolution" Entry 1.
111-947   B        221      Description: System beeper not functioning
                           correctly.
111-999   D        210      Description: System does not perform a
                           soft reset.
2E6-212   D        2E6      Description: FIFO empty bit set.
                           Action: Go to Chapter 7. "MAP 0050: SCSI
                  221      Problems Isolation Procedure".

2E6-213   D        2E6      Description: FIFO empty bit clear.
                           Action: Go to Chapter 7. "MAP 0050: SCSI
                  221      Problems Isolation Procedure".

2E6-214   D        2E6      Description: FIFO full bit set.
                           Action: Go to Chapter 7. "MAP 0050: SCSI
                  221      Problems Isolation Procedure".

2E6-215   D        2E6      Description: FIFO full bit clear.
                           Action: Go to Chapter 7. "MAP 0050: SCSI
                  221      Problems Isolation Procedure".

2E6-216   D        2E6      Description: FIFO data miscompare.
                           Action: Go to Chapter 7. "MAP 0050: SCSI
                  221      Problems Isolation Procedure".

2E6-217   D        2E6      Description: SCSI FIFO data miscompare.
                           Action: Go to Chapter 7. "MAP 0050: SCSI
                  221      Problems Isolation Procedure".

2E6-218   D        2E6      Description: SCSI FIFO underflow.
                           Action: Go to Chapter 7. "MAP 0050: SCSI
                  221      Problems Isolation Procedure".

2E6-219   D        2E6      Description: SCSI parity error.
                           Action: Go to Chapter 7. "MAP 0050: SCSI
                  221      Problems Isolation Procedure".

2E6-220   D        2E6      Description: SCSI FIFO flags error.
                           Action: Go to Chapter 7. "MAP 0050: SCSI
                  221      Problems Isolation Procedure".

2E6-221   D        2E6      Description: Miscompare during the
                           write/read of the configuration register.
                  221      Action: Go to Chapter 7. "MAP 0050: SCSI
                           Problems Isolation Procedure".
2E6-222   D        2E6      Description: Error during the write/read
                           of the memory register.
                  221      Action: Go to Chapter 7. "MAP 0050: SCSI
                           Problems Isolation Procedure".
2E6-223   D        2E6      Description: Miscompare during the
                           write/read of the memory I/O register.
                  221      Action: Go to Chapter 7. "MAP 0050: SCSI
                           Problems Isolation Procedure".
2E6-224   D        2E6      Description: Error reading the PCI
                           configuration register.
                  221

2E6-225   D        2E6      Description: Adapter POST failed.

                  221

2E6-230     D        D50      Description: Arbitration test failed.
                             Action: Go to Chapter 7. "MAP 0050: SCSI
                    2E6      Problems Isolation Procedure".

2E6-231     D        D50      Description: Function could not complete.
                             Action: Go to Chapter 7. "MAP 0050: SCSI
                    2E6      Problems Isolation Procedure".

2E6-232     D        D50      Description: SCSI bus data miscompare.
                             Action: Go to Chapter 7. "MAP 0050: SCSI
                    2E6      Problems Isolation Procedure".

2E6-240     D        2E6      Description: No terminal power.
                             Action: Go to Chapter 7. "MAP 0050: SCSI
                    221      Problems Isolation Procedure".

2E6-301     D        2E6      Description: Configuration open failed for
                             parent bus.
                    D50

                  software

2E6-700     G        2E6      Description: Error log analysis indicates
                             a PCI SCSI adapter failure.
                  software

2E6-701     G        2E6      Description: Error log analysis indicates
                             a PCI SCSI adapter failure.
                  software

2E6-702     G        2E6      Description: Error log analysis indicates
                             a PCI SCSI adapter failure.
                  software

2E6-703     G        2E6      Description: Error log analysis indicates
                             a PCI SCSI adapter failure.
                  software

2E6-704     G        2E6      Description: Error log analysis indicates
                             a PCI SCSI adapter failure.
                  software

2E6-705     G        2E6      Description: Error log analysis indicates
                             a PCI SCSI adapter failure.
                  software

2E6-800     G        2E6      Description: Error log analysis indicates
                             a PCI SCSI adapter PTC failure.
                             Action: Go to Chapter 7. "MAP 0050: SCSI
                             Problems Isolation Procedure".
2E6-802     G        2E6      Description: Error log analysis indicates
                             a PCI SCSI bus failure.
                             Action: Go to Chapter 7. "MAP 0050: SCSI
                             Problems Isolation Procedure".
2E7-212     D        2E7      Description: FIFO empty bit set.
                             Action: Go to Chapter 7. "MAP 0050: SCSI
                    221      Problems Isolation Procedure".

2E7-213     D        2E7      Description: FIFO empty bit clear.
                             Action: Go to Chapter 7. "MAP 0050: SCSI
                    221      Problems Isolation Procedure".

2E7-214     D        2E7      Description: FIFO full bit set.
                             Action: Go to Chapter 7. "MAP 0050: SCSI
                    221      Problems Isolation Procedure".

2E7-215     D        2E7      Description: FIFO full bit clear.
                             Action: Go to Chapter 7. "MAP 0050: SCSI
                    221      Problems Isolation Procedure".

2E7-216     D        2E7      Description: FIFO data miscompare.
                             Action: Go to Chapter 7. "MAP 0050: SCSI
                    221      Problems Isolation Procedure".

2E7-217     D        2E7      Description: SCSI FIFO data miscompare.
                             Action: Go to Chapter 7. "MAP 0050: SCSI
                    221      Problems Isolation Procedure".

2E7-218     D        2E7      Description: SCSI FIFO underflow.
                             Action: Go to Chapter 7. "MAP 0050: SCSI
                    221      Problems Isolation Procedure".

2E7-219     D        2E7      Description: SCSI parity error.
                             Action: Go to Chapter 7. "MAP 0050: SCSI
                    221      Problems Isolation Procedure".

2E7-220     D        2E7      Description: SCSI FIFO flags error.
                             Action: Go to Chapter 7. "MAP 0050: SCSI
                    221      Problems Isolation Procedure".

2E7-221     D        2E7      Description: Miscompare during the
                             write/read of the configuration register.
                    221      Action: Go to Chapter 7. "MAP 0050: SCSI
                             Problems Isolation Procedure".
2E7-222     D        2E7      Description: Error during the write/read
                             of the memory register.
                    221      Action: Go to Chapter 7. "MAP 0050: SCSI
                             Problems Isolation Procedure".
2E7-223     D        2E7      Description: Miscompare during the
                             write/read of the memory I/O register.
                    221      Action: Go to Chapter 7. "MAP 0050: SCSI
                             Problems Isolation Procedure".
2E7-224     D        2E7      Description: Error reading the PCI
                             configuration register.
                    221

2E7-225     D        2E7      Description: Adapter POST failed.

                    221

2E7-230     D        D50      Description: Arbitration test failed.
                             Action: Go to Chapter 7. "MAP 0050: SCSI
                    2E7      Problems Isolation Procedure".

2E7-231     D        D50      Description: Function could not complete.
                             Action: Go to Chapter 7. "MAP 0050: SCSI
                    2E7      Problems Isolation Procedure".

2E7-232     D        D50      Description: SCSI bus data miscompare.
                             Action: Go to Chapter 7. "MAP 0050: SCSI
                    2E7      Problems Isolation Procedure".

2E7-240     D        2E7      Description: No terminal power.
                             Action: Go to Chapter 7. "MAP 0050: SCSI
                    221      Problems Isolation Procedure".

2E7-301     D        2E7      Description: Configuration open failed for
                             parent bus.
                    D50

                  software

2E7-700     G        2E7      Description: Error log analysis indicates
                             a PCI SCSI adapter failure.
                  software

2E7-701     G        2E7      Description: Error log analysis indicates
                             a PCI SCSI adapter failure.
                  software

2E7-702     G        2E7      Description: Error log analysis indicates
                             a PCI SCSI adapter failure.
                  software

2E7-703     G        2E7      Description: Error log analysis indicates
                             a PCI SCSI adapter failure.
                  software

2E7-704     G        2E7      Description: Error log analysis indicates
                             a PCI SCSI adapter failure.
                  software

2E7-705     G        2E7      Description: Error log analysis indicates
                             a PCI SCSI adapter failure.
                  software

2E7-800     G        2E7      Description: Error log analysis indicates
                             a PCI SCSI adapter PTC failure.
                             Action: Go to Chapter 7. "MAP 0050: SCSI
                             Problems Isolation Procedure".
2E7-802     G        2E7      Description: Error log analysis indicates
                             a PCI SCSI bus failure.
                             Action: Go to Chapter 7. "MAP 0050: SCSI
                             Problems Isolation Procedure".
2EF-101     E        751      Description: Post indicates an adapter
                             failure.
650-xxx     D        650      Description: Disk drive configuration
                             failed.
651-140     D        165      Description: Operator panel display test
                             failed
                    221

651-150     D        166      Description: Sensor indicates a fan has
                             failed.
                    2E0      Action: Use Chapter 13. "MAP 0220 Hot Plug
                             FRU Problem Resolution".
651-151     D        152      Description: Sensor indicates a voltage is
                             outside the normal range.
                    2E2      Action: Use MAP 1520.

651-152     D        2E1      Description: Sensor indicates an
                             abnormally high internal temperature.
                             Action: Verify that:

                               1. The room ambient temperature is within
                                  the system operating environment.

                               2. There is unrestricted air flow around
                                  the system.

                               3. All system covers are closed.

                               4. There are no fan failures.

                             If none of these problems exist, then
                             proceed with Chapter 13. "MAP 0220 Hot Plug
                             FRU Problem Resolution".
651-153     D        152      Description: Sensor indicates a power
                             supply has failed.
                    E19      Action: Use Chapter 13. "MAP 0220 Hot Plug
                             FRU Problem Resolution".
651-159     D                 Description: Sensor indicates a FRU has
                             failed.
                             Action: Use the physical location code(s)
                             to replace the FRU(s) that are identified
                             on the diagnostics problem report screen.
651-160     D        166      Description: Sensor indicates a fan is
                             turning too slowly.
                    2E0      Action: Use Chapter 13. "MAP 0220 Hot Plug
                             FRU Problem Resolution".
651-161     D        152      Description: Sensor indicates a voltage is
                             outside the normal range.
                    2E2      Action: Use MAP 1520.

651-162     D        2E1      Description: Sensor indicates an
                             abnormally high internal temperature.
                             Action: Verify that:

                               1. The room ambient temperature is within
                                  the system operating environment.

                               2. There is unrestricted air flow around
                                  the system.

                               3. All system covers are closed.

                               4. There are no fan failures.

                             If none of these problems exist, then
                             proceed with Chapter 13. "MAP 0220 Hot Plug
                             FRU Problem Resolution".
651-163     D        152      Description: Sensor indicates a power
                             supply has failed.
                    E19      Action: Use Chapter 13. "MAP 0220 Hot Plug
                             FRU Problem Resolution".
651-169     D                 Description: Sensor indicates a FRU has
                             failed
                             Action: Use the physical location codes to
                             replace the FRUs that are identified on the
                             diagnostics problem report screen.
651-170     D                 Description: Sensor status not available.
                             Action: Contact your support person.
651-171     D                 Description: Sensor status not available
                             Action: Contact your support person.
651-600     G                 Description: Uncorrectable memory or
                             unsupported memory.
                             Action: Examine the memory modules and
                             determine if they are supported types. If
                             the modules are supported, then replace the
                             appropriate memory module(s).
651-601     G                 Description: Missing or bad memory
                             Action: If the installed memory matches the
                             reported memory size, then replace the
                             memory: otherwise, add the missing memory.

651-602     G        2C5      Description: Bad or missing memory
                             Action: Use Chapter 14. "MAP 0240: Memory
                             Problem Resolution".
651-603     G        2C6      Description: Bad or missing memory
                             Action: Use Chapter 14. "MAP 0240: Memory
                             Problem Resolution".
651-608     G        D01      Description: Bad L2 Cache

651-609     G        D01      Description: Missing L2 Cache

651-610     G        210      Description: CPU internal error

651-611     G        210      Description: CPU internal cache error

651-612     G        D01      Description: L2 Cache parity or multi-bit
                             ECC error
651-613     G        D01      Description: L2 cache ECC single-bit error

651-614     G        214      Description: Time-out error waiting for
                             memory controller
651-615     G        292      Description: Time-out error waiting for
                             I/O
651-619     G                 Description: Error log analysis indicates
                             an error detected by the CPU. The error log
                             indicates the following physical FRU
                             location(s) as the probable cause(s).
                             Action: Use the physical location codes to
                             replace the FRUs that are identified on the
                             diagnostics problem report screen.
651-620     G        2C5      Description: ECC correctable error
                             Action: Use Chapter 14. "MAP 0240: Memory
                             Problem Resolution".
651-621     G        2C6      Description: ECC correctable error
                             Action: Use Chapter 14. "MAP 0240: Memory
                             Problem Resolution".
651-622     G        2C5      Description: Correctable error threshold
                             exceeded
                             Action: Use Chapter 14. "MAP 0240: Memory
                             Problem Resolution".
651-623     G        2C6      Description: Correctable error threshold
                             exceeded
                             Action: Use Chapter 14. "MAP 0240: Memory
                             Problem Resolution".
651-624     G        214      Description: Memory controller internal
                             error
651-625     G        214      Description: Memory Address (Bad address
                             going to memory)
651-626     G        214      Description: Memory Data error (Bad data
                             going to memory)
651-627     G        214      Description: Memory time-out error

651-628     G        210      Description: Processor time-out error

651-629     G                 Description: Error log analysis indicates
                             and error detected by the memory
                             controller. The error log indicates the
                             following physical FRU location(s) as the
                             probable cause(s).
                             Action: Use the physical location codes to
                             replace the FRUs that are identified on the
                             diagnostics problem report screen.
651-630     G        307      Description: I/O Expansion Bus Parity
                             Error.
651-631     G        307      Description: I/O Expansion Bus Time-out
                             Error.
651-632     G        306      Description: Internal Device Error.

                    307

                    308

651-633     G        307      Description: I/O Expansion Unit not in an
                             operating state.
                    306

651-634     G        307      Description: Internal Device Error.

651-639     G                 Description: Error log analysis indicates
                             an error detected by the I/O. The error log
                             indicates the following physical FRU
                             location(s) as the probable cause(s).
                             Action: Use the physical location codes to
                             replace the FRUs that are identified on the
                             diagnostics problem report screen.
651-640     G        2D5      Description: I/O general bus error.

651-641     G        2D6      Description: Secondary I/O general bus
                             error
651-642     G        2D3      Description: Internal Service Processor
                             memory error
651-643     G        2D3      Description: Internal Service Processor
                             firmware error
651-644     G        2D3      Description: Other internal Service
                             Processor hardware error
651-650     G        E17      Description: ECC correctable error.
                             Action: Use Chapter 14. "MAP 0240: Memory
                             Problem Resolution".
651-651     G        E18      Description: ECC correctable error.
                             Action: Use Chapter 14. "MAP 0240: Memory
                             Problem Resolution".
651-652     G        300      Description: ECC correctable error.
                             Action: Use Chapter 14. "MAP 0240: Memory
                             Problem Resolution".
651-653     G        301      Description: ECC correctable error.
                             Action: Use Chapter 14. "MAP 0240: Memory
                             Problem Resolution".
651-654     G        302      Description: ECC correctable error.
                             Action: Use Chapter 14. "MAP 0240: Memory
                             Problem Resolution".
651-655     G        303      Description: ECC correctable error.
                             Action: Use Chapter 14. "MAP 0240: Memory
                             Problem Resolution".
651-656     G        304      Description: ECC correctable error.
                             Action: Use Chapter 14. "MAP 0240: Memory
                             Problem Resolution".
651-657     G        305      Description: ECC correctable error.
                             Action: Use Chapter 14. "MAP 0240: Memory
                             Problem Resolution".
651-660     G        E17      Description: Correctable error threshold
                             exceeded.
                             Action: Use Chapter 14. "MAP 0240: Memory
                             Problem Resolution".
651-661     G        E18      Description: Correctable error threshold
                             exceeded.
                             Action: Use Chapter 14. "MAP 0240: Memory
                             Problem Resolution".
651-662     G        300      Description: Correctable error threshold
                             exceeded.
                             Action: Use Chapter 14. "MAP 0240: Memory
                             Problem Resolution".
651-663     G        301      Description: Correctable error threshold
                             exceeded.
                             Action: Use Chapter 14. "MAP 0240: Memory
                             Problem Resolution".
651-664     G        302      Description: Correctable error threshold
                             exceeded.
                             Action: Use Chapter 14. "MAP 0240: Memory
                             Problem Resolution".
651-665     G        303      Description: Correctable error threshold
                             exceeded.
                             Action: Use Chapter 14. "MAP 0240: Memory
                             Problem Resolution".
651-666     G        304      Description: Correctable error threshold
                             exceeded.
                             Action: Use Chapter 14. "MAP 0240: Memory
                             Problem Resolution".
651-667     G        305      Description: Correctable error threshold
                             exceeded.
                             Action: Use Chapter 14. "MAP 0240: Memory
                             Problem Resolution".
651-670     G        E17      Description: Bad or missing memory.
                             Action: Use Chapter 14. "MAP 0240: Memory
                             Problem Resolution".
651-671     G        E18      Description: Bad or missing memory.
                             Action: Use Chapter 14. "MAP 0240: Memory
                             Problem Resolution".
651-672     G        300      Description: Bad or missing memory.
                             Action: Use Chapter 14. "MAP 0240: Memory
                             Problem Resolution".
651-673     G        301      Description: Bad or missing memory.
                             Action: Use Chapter 14. "MAP 0240: Memory
                             Problem Resolution".
651-674     G        302      Description: Bad or missing memory.
                             Action: Use Chapter 14. "MAP 0240: Memory
                             Problem Resolution".
651-675     G        303      Description: Bad or missing memory.
                             Action: Use Chapter 14. "MAP 0240: Memory
                             Problem Resolution".
651-676     G        304      Description: Bad or missing memory.
                             Action: Use Chapter 14. "MAP 0240: Memory
                             Problem Resolution".
651-677     G        305      Description: Bad or missing memory.
                             Action: Use Chapter 14. "MAP 0240: Memory
                             Problem Resolution".
651-710     G        214      Description: Address/Data parity error on
                             Processor bus
                    2C4

651-711     G        214      Description: Address/Data parity error on
                             Processor bus
                    210

                    2C4

651-712     G        214      Description: Address/Data parity error on
                             Processor bus
                    210

                    210

                    2C4

651-713     G        214      Description: Transfer error on Processor
                             bus
                    2C4

651-714     G        214      Description: Transfer error on Processor
                             bus
                    210

                    2C4

651-715     G        214      Description: Transfer error on Processor
                             bus
                    210

                    210

                    2C4

651-720     G        2C5      Description: Uncorrectable Memory Error
                             Action: Use Chapter 14. "MAP 0240: Memory
                    2C7      Problem Resolution".

                    214

651-721     G        2C6      Description: Uncorrectable Memory Error
                             Action: Use Chapter 14. "MAP 0240: Memory
                    2C7      Problem Resolution".

                    214

651-722     G        210      Description: Processor bus parity error

                    2C4

                    214

651-723     G        210      Description: Processor bus parity error

                    2C4

                    214

651-724     G        292      Description: I/O Host Bridge time-out
                             error
                    2C8

                    214

                    763

651-725     G        292      Description: I/O Host Bridge address/data
                             parity error
                    2C8

                    214

                    763

651-730     G                 Description: I/O error on the ISA bus.
                             Action: Refer to the Bus SRN to FRU
                             Reference Table in the system unit's
                             service guide.
651-731     G        2C8      Description: Intermediate or System Bus
                             Address Parity Error.
                    292

                    763

651-732     G        2C8      Description: Intermediate or System Bus
                             Data Parity Error.
                    292

                    763

651-733     G        214      Description: Intermediate or System Bus
                             Address Parity Error.
                    2C8

                    292

651-734     G        214      Description: Intermediate or System Bus
                             Data Parity Error.
                    2C8

                    292

651-735     G        2D2      Description: Intermediate or System Bus
                             Time-out Error.
                    292

651-736     G        2D2      Description: Intermediate or System Bus
                             Time-out Error.
                    292

                    214

651-740     G        2D3      Description: Time-out on communication
                             response from Service Processor
                    2D4

651-741     G        2D3      Description: Service Processor error
                             accessing special registers
                    2D4

651-742     G        2D3      Description: Service Processor reports
                             unknown communication error
                    2D4

651-743     G        2D7      Description: Service Processor error
                             accessing Vital Product Data EEPROM
                    2D5

651-744     G        165      Description: Service Processor error
                             accessing Operator Panel
                    2D5

                    2D3

651-745     G        2D9      Description: Service Processor error
                             accessing Power Controller
                    2D5

651-746     G        2E0      Description: Service Processor error
                             accessing Fan Sensor
                    2D5

651-747     G        2E1      Description: Service Processor error
                             accessing Thermal Sensor
                    2D5

651-748     G        2E2      Description: Service Processor error
                             accessing Voltage Sensor
                    2D5

651-749     G        2E3      Description: Service Processor error
                             accessing Serial Port
                    2D4

651-750     G        814      Description: Service Processor error
                             accessing NVRAM
                    2D4

651-751     G        817      Description: Service Processor error
                             accessing Real-Time Clock/Time-of-Day Clock
                    2D4

651-752     G        2E4      Description: Service Processor error
                             accessing JTAG/COP controller/hardware
                    2D4

651-753     G        151      Description: Service Processor detects
                             loss of voltage from the Time-of-Day Clock
                    2D4      backup battery

651-760     G     software    Description: Service Processor caused a
                             reboot of the system due to a surveillance
                  hardware   time-out.
                             Action: A surveillance time-out is caused
                             by lack of response from the operating
                             system. The most likely cause is a software
                             or operating system failure. Verify that
                             the problem is not related to hardware by
                             running diagnostics, in Problem
                             Determination Mode, on all resources which
                             have not already been run. Also, the system
                             administrator should look for other
                             symptoms that would indicate a software or
                             operating system problem. Contact the
                             software support structure for assistance
                             in needed.
651-770     G        2C8      Description: Intermediate or System Bus
                             Address Parity Error.
                    292

                    306

651-771     G        2C8      Description: Intermediate or System Bus
                             Data Parity Error.
                    292

                    306

651-772     G        2D2      Description: Intermediate or System Bus
                             Time-out Error.
                    292

                    306

651-773     G        227      Description: Intermediate or System Bus
                             Data Parity Error.
651-780     G        E17      Description: Uncorrectable Memory Error.
                             Action: Use Chapter 14. "MAP 0240: Memory
                    2C7      Problem Resolution".

                    214

651-781     G        E18      Description: Uncorrectable Memory Error.
                             Action: Use Chapter 14. "MAP 0240: Memory
                    2C7      Problem Resolution".

                    214

651-782     G        300      Description: Uncorrectable Memory Error.
                             Action: Use Chapter 14. "MAP 0240: Memory
                    214      Problem Resolution".

651-783     G        301      Description: Uncorrectable Memory Error.
                             Action: Use Chapter 14. "MAP 0240: Memory
                    214      Problem Resolution".

651-784     G        302      Description: Uncorrectable Memory Error.
                             Action: Use Chapter 14. "MAP 0240: Memory
                    214      Problem Resolution".

651-785     G        303      Description: Uncorrectable Memory Error.
                             Action: Use Chapter 14. "MAP 0240: Memory
                    214      Problem Resolution".

651-786     G        304      Description: Uncorrectable Memory Error.
                             Action: Use Chapter 14. "MAP 0240: Memory
                    214      Problem Resolution".

651-787     G        305      Description: Uncorrectable Memory Error.
                             Action: Use Chapter 14. "MAP 0240: Memory
                    214      Problem Resolution".

651-800     G        166      Description: Fan is turning slower than
                             expected
                    2E0

651-801     G        166      Description: Over voltage condition was
                             detected
                    2E0      Action: Verify the following:

                                * nothing is obstructing the fan
                                  rotation

                                * the fan power connection is tight

                                * the fan speed sensing cable is tight

                             If the fan still is not turning replace the
                             fan. If the fan is turning, replace the fan
                             sensor FRU.
651-810     G        152      Description: Over voltage condition was
                             detected
                    2E2      Action: Verify that all DC voltages are
                             within specifications. If all of the
                             voltages are within specifications, replace
                             the voltage sensor FRU, otherwise replace
                             the power supply FRU.
651-811     G        152      Description: Under voltage condition was
                             detected
                    2E2      Action: Verify that all DC voltages are
                             within specifications. If all of the
                             voltages are within specifications, replace
                             the voltage sensor FRU, otherwise replace
                             the power supply FRU.
651-812     G        152      Description: System shutdown due to:

                               1. Loss of AC power

                               2. Power button was pushed without proper
                                  system shutdown

                               3. Power supply failure

                             Action: If reasons 1 and 2 can be ruled out
                             than replace the power supply FRU.
651-813     G                 Description: System shutdown due to loss
                             of AC Power to the site.
                             Action: System resumed normal operation, no
                             action required.
651-814     G        152      Description: CEC Rack shutdown due to one
                             of the following:

                               1. Loss of AC power to the CEC Rack
                               2. Open or disconnected SPCN cable
                                  between racks
                               3. AC module, Bulk power, regulator or
                                  SPCN card failure.

                             Action: If 1 and 2 can be ruled out and the
                             problem can be recreated, try the power
                             supply related FRUs one at a time to
                             isolate the problem.
651-815     G        287      Description: I/O Rack shutdown due to one
                             of the following:
                    289
                               1. Loss of AC power to the I/O Rack
                               2. Open or disconnected SPCN cable
                                  between racks
                               3. Power supply failure

                             Action: If 1 and 2 can be ruled out, then
                             replace the power supply FRU.
651-816     G        287      Description: Power fault due to internal
                             power supply failure.
651-817     G        289      Description: Power fault due to internal
                             power supply failure.
651-818     G                 Description: Power fault due to manual
                             activation of power-off request.
                             Action: Resume normal operation.
651-820     G        2E1      Description: An over temperature condition
                             was detected
                             Action: Verify the following:

                                * the room ambient temperature is within
                                  the system operating environment

                                * there is unrestricted air flow around
                                  the system

                                * all system covers are closed

                             If all conditions are met, then replace the
                             temperature sensor FRU.
651-821     G        2E1      Description: System shutdown due to an
                             over maximum temperature condition being
                             reached.
                             Action: Verify the following:

                                * The room ambient temperature is within
                                  the system operating environment.

                                * There is unrestricted air flow around
                                  the system.

                                * All system covers are closed.

                             If all conditions are met, then replace the
                             temperature sensor FRU.
651-822     G        166      Description: System shutdown due to over
                             temperature condition and fan failure. Use
                    2E1      the physical FRU location(s) as the
                             probable cause(s).
                             Action: Use the physical location codes to
                             replace the FRUs that are identified on the
                             diagnostics problem report screen.
651-830     G        166      Description: Sensor detected a fan
                             failure.
                    2E0      Action: Use Chapter 13. "MAP 0220 Hot Plug
                             FRU Problem Resolution".
651-831     G        152      Description: Sensor detected a voltage
                             outside of the normal range.
                    2E2      Action: Use MAP 1520.

651-832     G        2E1      Description: Sensor detected an abnormally
                             high internal temperature.
                             Action: Verify that:

                               1. The room ambient temperature is within
                                  the system operating environment.

                               2. There is unrestricted air flow around
                                  the system.

                               3. All system covers are closed.

                               4. There are no fan failures.

                             If none of these problems exist, then
                             proceed with Chapter 13. "MAP 0220 Hot Plug
                             FRU Problem Resolution".
651-833     G        152      Description: Sensor detected a power
                             supply failure.
                    E19      Action: Use Chapter 13. "MAP 0220 Hot Plug
                             FRU Problem Resolution".
651-839     G                 Description: Sensor detected a FRU that
                             has failed.
                             Action: Use the physical location code(s)
                             to replace the FRU(s) that are identified
                             on the diagnostics problem report screen.
651-840     G        166      Description: Sensor detected a fan
                             failure.
                    2E0      Action: Use Chapter 13. "MAP 0220 Hot Plug
                             FRU Problem Resolution".
651-841     G        152      Description: Sensor detected a voltage
                             outside of the normal range.
                    2E2      Action: Use MAP 1520.

651-842     G        2E1      Description: Sensor detected an abnormally
                             high internal temperature.
                             Action: Verify that:

                               1. The room ambient temperature is within
                                  the system operating environment.

                               2. There is unrestricted air flow around
                                  the system.

                               3. All system covers are closed.

                               4. There are no fan failures.

                             If none of these problems exist, then
                             proceed with Chapter 13. "MAP 0220 Hot Plug
                             FRU Problem Resolution".
651-843     G        152      Description: Sensor detected a power
                             supply failure.
                    E19      Action: Use Chapter 13. "MAP 0220 Hot Plug
                             FRU Problem Resolution".
651-849     G                 Description: Sensor detected a FRU that
                             has failed.
                             Action: Use the physical location code(s)
                             to replace the FRU(s) that are identified
                             on the diagnostics problem report screen.
651-88x     G                 Description: The CEC or SPCN reported an
                             error.
                             Action: If reference and location codes
                             were reported with this SRN, refer to this
                             system unit's system service guide with the
                             reference and location codes for the
                             necessary repair action. If the reference
                             and location codes were NOT reported, then
                             run Diagnostics in Problem Determination
                             mode and record and report the reference
                             and location codes for this SRN.
651-89x     G                 Description: The CEC or SPCN reported an
                             error.
                             Action: Refer to the this system unit's
                             system service guide, with the reference
                             and location codes, for the necessary
                             repair action. If the reference and
                             location codes were NOT reported, then run
                             Advanced Diagnostics in Problem
                             Determination mode and record and report
                             the reference and location codes for this
                             SRN.
652-600     G                 Description: A non-critical error has been
                             detected and corrected: Uncorrectable
                             memory or unsupported memory.
                             Action: Schedule deferred maintenance.
                             Examine the memory modules and determine if
                             they are supported types. If the modules
                             are supported, then replace the appropriate
                             memory module(s).
652-610     G        210      Description: A non-critical error has been
                             detected and corrected: CPU internal error.

                             Action: Schedule deferred maintenance. Use
                             Chapter 12. "MAP 0210: General Problem
                             Resolution".
652-611     G        210      Description: A non-critical error has been
                             detected and corrected: CPU internal cache
                             error.
                             Action: Schedule deferred maintenance. Use
                             Chapter 12. "MAP 0210: General Problem
                             Resolution"
652-612     G        D01      Description: A non-critical error has been
                             detected and corrected: L2 cache parity or
                             multi-bit ECC error.
                             Action: Schedule deferred maintenance. Use
                             Chapter 12. "MAP 0210: General Problem
                             Resolution".
652-613     G        D01      Description: A non-critical error has been
                             detected and corrected: L2 cache ECC
                             single-bit error.
                             Action: Schedule deferred maintenance. Use
                             Chapter 12. "MAP 0210: General Problem
                             Resolution"
652-622     G        2C5      Description: A non-critical error has been
                             detected and corrected: Correctable error
                             threshold exceeded.
                             Action: Schedule deferred maintenance. Use
                             Chapter 14. "MAP 0240: Memory Problem
                             Resolution".
652-623     G        2C6      Description: A non-critical error has been
                             detected and corrected: Correctable error
                             threshold exceeded.
                             Action: Schedule deferred maintenance. Use
                             Chapter 14. "MAP 0240: Memory Problem
                             Resolution".
652-630     G        307      Description: A non-critical error has been
                             detected and corrected: I/O Expansion Bus
                             Parity Error.
                             Action: Schedule deferred maintenance. Use
                             Chapter 12. "MAP 0210: General Problem
                             Resolution".
652-631     G        307      Description: A non-critical error has been
                             detected and corrected: I/O Expansion Bus
                             Time-out Error.
                             Action: Schedule deferred maintenance. Use
                             Chapter 12. "MAP 0210: General Problem
                             Resolution".
652-632     G        306      Description: A non-critical error has been
                             detected and corrected: I/O Expansion Bus
                    307      Connection Failure.
                             Action: Schedule deferred maintenance. Use
                    308      Chapter 12. "MAP 0210: General Problem
                             Resolution".
652-633     G        307      Description: A non-critical error has been
                             detected and corrected: I/O Expansion Unit
                    306      not in an operating state.
                             Action: Schedule deferred maintenance. Use
                             Chapter 12. "MAP 0210: General Problem
                             Resolution".
652-634     G        307      Description: A non-critical error has been
                             detected and corrected: Internal Device
                             Error.
                             Action: Schedule deferred maintenance. Use
                             Chapter 12. "MAP 0210: General Problem
                             Resolution".
652-660     G        E17      Description: A non-critical error has been
                             detected and corrected: Correctable error
                             threshold exceeded.
                             Action: Schedule deferred maintenance. Use
                             Chapter 14. "MAP 0240: Memory Problem
                             Resolution".
652-661     G        E18      Description: A non-critical error has been
                             detected and corrected: Correctable error
                             threshold exceeded.
                             Action: Schedule deferred maintenance. Use
                             Chapter 14. "MAP 0240: Memory Problem
                             Resolution".
652-662     G        300      Description: A non-critical error has been
                             detected and corrected: Correctable error
                             threshold exceeded.
                             Action: Schedule deferred maintenance. Use
                             Chapter 14. "MAP 0240: Memory Problem
                             Resolution".
652-663     G        301      Description: A non-critical error has been
                             detected and corrected: Correctable error
                             threshold exceeded.
                             Action: Schedule deferred maintenance. Use
                             Chapter 14. "MAP 0240: Memory Problem
                             Resolution".
652-664     G        302      Description: A non-critical error has been
                             detected and corrected: Correctable error
                             threshold exceeded.
                             Action: Schedule deferred maintenance. Use
                             Chapter 14. "MAP 0240: Memory Problem
                             Resolution".
652-665     G        303      Description: A non-critical error has been
                             detected and corrected: Correctable error
                             threshold exceeded.
                             Action: Schedule deferred maintenance. Use
                             Chapter 14. "MAP 0240: Memory Problem
                             Resolution".
652-666     G        304      Description: A non-critical error has been
                             detected and corrected: Correctable error
                             threshold exceeded.
                             Action: Schedule deferred maintenance. Use
                             Chapter 14. "MAP 0240: Memory Problem
                             Resolution".
652-667     G        305      Description: A non-critical error has been
                             detected and corrected: Correctable error
                             threshold exceeded.
                             Action: Schedule deferred maintenance. Use
                             Chapter 14. "MAP 0240: Memory Problem
                             Resolution".
652-731     G        2C8      Description: A non-critical error has been
                             detected and corrected: Intermediate or
                    292      System Bus Address Parity Error.
                             Action: Schedule deferred maintenance. Use
                             Chapter 12. "MAP 0210: General Problem
                             Resolution".
652-732     G        2C8      Description: A non-critical error has been
                             detected and corrected: Intermediate or
                    292      System Bus Data Parity Error.
                             Action: Schedule deferred maintenance. Use
                             Chapter 12. "MAP 0210: General Problem
                             Resolution".
652-733     G        214      Description: A non-critical error has been
                             detected and corrected: Intermediate or
                    2C8      System Bus Address Parity Error.
                             Action: Schedule deferred maintenance. Use
                    292      Chapter 12. "MAP 0210: General Problem
                             Resolution".
652-734     G        214      Description: A non-critical error has been
                             detected and corrected: Intermediate or
                    2C8      System Bus Data Parity Error.
                             Action: Schedule deferred maintenance. Use
                    292      Chapter 12. "MAP 0210: General Problem
                             Resolution".
652-735     G        2D2      Description: A non-critical error has been
                             detected and corrected: Intermediate or
                    292      System Bus Time-out Error.
                             Action: Schedule deferred maintenance. Use
                             Chapter 12. "MAP 0210: General Problem
                             Resolution".
652-736     G        2D2      Description: A non-critical error has been
                             detected and corrected: Intermediate or
                    292      System Bus Time-out Error.
                             Action: Schedule deferred maintenance. Use
                    214      Chapter 12. "MAP 0210: General Problem
                             Resolution".
652-770     G        2C8      Description: A non-critical error has been
                             detected and corrected: Intermediate System
                    292      Bus Address Parity Error.
                             Action: Schedule deferred maintenance. Use
                    306      Chapter 12. "MAP 0210: General Problem
                             Resolution".
652-771     G        2C8      Description: A non-critical error has been
                             detected and corrected: Intermediate or
                    292      System Bus Data Parity Error.
                             Action: Schedule deferred maintenance. Use
                    306      Chapter 12. "MAP 0210: General Problem
                             Resolution".
652-772     G        2D2      Description: A non-critical error has been
                             detected and corrected: Intermediate or
                    292      System Bus Time-out Error.
                             Action: Schedule deferred maintenance. Use
                    306      Chapter 12. "MAP 0210: General Problem
                             Resolution".
652-773     G        227      Description: A non-critical error has been
                             detected and corrected. Intermediate or
                             System Bus Data Parity Error.
                             Action: Schedule deferred maintenance. Use
                             Chapter 12. "MAP 0210: General Problem
                             Resolution".
652-810     G        152      Description: Non-critical power problem,
                             loss of redundant supply. Use the physical
                             FRU location(s) as the probable cause(s).
                             Action: Schedule maintenance. Use the
                             physical location codes to replace the FRUs
                             that are identified on the diagnostics
                             problem report screen.
652-820     G        166      Description: Non-critical cooling problem,
                             loss of redundant fan. Use the physical FRU
                             location(s) as the probable cause(s).
                             Action: Schedule maintenance. Use the
                             physical location codes to replace the FRUs
                             that are identified on the diagnostics
                             problem report screen.
652-830     G        166      Description: Sensor detected a redundant
                             fan failure.
                    2E0      Action: Use Chapter 13. "MAP 0220 Hot Plug
                             FRU Problem Resolution".
652-833     G        152      Description: Sensor detected a redundant
                             power supply failure.
                    E19      Action: Use Chapter 13. "MAP 0220 Hot Plug
                             FRU Problem Resolution".
652-839     G                 Description: Sensor detected a redundant
                             FRU failure.
                             Action: Use the physical location code(s)
                             to replace the FRU(s) that are identified
                             on the diagnostics problem report screen.
652-88x     G                 Description: The CEC or SPCN reported a
                             non-critical error.
                             Action: Schedule deferred maintenance. If
                             reference and location codes were reported
                             with this SRN, refer to this system unit's
                             system service guide with the reference and
                             location codes for the necessary repair
                             action. If the reference and location codes
                             were NOT reported, then run Diagnostics in
                             Problem Determination mode and record and
                             report the reference and location codes for
                             this SRN.
652-89x     G                 Description: The CEC or SPCN reported a
                             non-critical error.
                             Action: Schedule deferred maintenance.
                             Refer to the this system unit's system
                             service guide, with the reference and
                             location codes, for the necessary repair
                             action. If the reference and location codes
                             were NOT reported, then run Advanced
                             Diagnostics in Problem Determination mode
                             and record and report the reference and
                             location codes for this SRN.
664-098     J        664      Description: IPLROS detected a problem
                             with the CD-ROM drive
                    B88

                    221

664-099     J        664      Description: IPLROS detected a problem
                             with the CD-ROM drive
                    B88

664-111     D        664      Description: Unable to reserve device.

                    B88

664-112     D        664      Description: Unable to do configuration.

                    B88

664-113     D        664      Description: Unable to open the device
                             driver.
                    B88

664-121     D        664      Description: The CD-ROM drive indicates an
                             error.
664-122     D        664      Description: The CD-ROM drive indicates an
                             error.
664-123     D        664      Description: The CD-ROM drive indicates an
                             error.
664-125     D        664      Description: The CD-ROM drive indicates an
                             error.
                    B88

664-126     D        664      Description: The CD-ROM drive indicates an
                             error.
664-127     D        664      Description: The CD-ROM drive indicates an
                             error.
664-128     D        664      Description: The CD-ROM drive indicates an
                             error.
664-129     D        664      Description: The CD-ROM drive indicates an
                             error.
664-150     D       Media     Description: A media error was detected.

                    664

664-151     D        664      Description: A command timeout was
                             detected.
                    D88

664-152     D        664      Description: A command reservation
                             conflict was detected.
664-162     D        664      Description: The CD-ROM drive indicates an
                             error.
664-171     D        664      Description: Unable to reserve device.

664-172     D        664      Description: Unable to do configuration.

664-173     D        664      Description: Unable to open device driver.

664-175     D        664      Description: The CD-ROM drive indicates an
                             error.
664-198     D        664      Description: Undefined error detected.

                    B88

664-199     D        664      Description: Undefined error detected.

664-211     D        664      Description: The LED test failed.

664-281     D        664      Description: No tone during audio test.

664-301     G        664      Description: Errors found during ELA.

664-302     G        664      Description: Errors found during ELA.

                    B88

669-201     D        669      Description: Configuration register test
                             failure
                    221

669-202     D        669      Description: I/O register test failure

                    221

669-203     D        669      Description: Adapter memory test failure

                    221

669-204     D        669      Description: Adapter initialization test
                             failure
                    221

669-205     D        669      Description: Internal loopback test
                             failure
                    221

669-206     D        669      Description: External loopback test
                             failure
                    221

669-701     G        669      Description: Error log analysis indicates
                             that this device failed to initialize
                             because it is not the IBM version of the
                             adapter. AIX cannot configure the non-IBM
                             version of this adapter
669-702     G        669      Description: Error Log Analysis indicates
                             that this device failed to initialize due
                    221      to a problem with the EEPROM on the
                             adapter.
669-703     G        669      Description: Error Log Analysis indicates
                             that this device has failed to initialize
                    221      due to a self-test failure.

669-704     D        669      Description: Error Log Analysis indicates
                             that this device has failed to initialize
                    221      due to firmware download error. The
                             microcode seems to be properly installed.
674-101     D        674      Description: Artic960 PCI Adapter Central
                             Processing Unit (CPU) test failure.
                    C94      Action: Use MAP 0210.

                    C95

674-102     D        674      Description: Artic960 PCI Adapter Timer
                             test failure.
                    C94      Action: Use MAP 0210.

                    C95

674-103     D        674      Description: Artic960 PCI Adapter Bus
                             Interface test failure.
                    C94      Action: Use MAP 0210.

                    C95

674-104     D        C94      Description: Artic960 PCI Adapter Dynamic
                             Random Access Memory (DRAM) test failure.
                    674      Action: Use MAP 0210.

                    C95

674-105     D        674      Description: Artic960 PCI Adapter Memory
                             Protection test failure.
                    C94      Action: Use MAP 0210.

                    C95

674-106     D        674      Description: Artic960 PCI Adapter Debug
                             Port test failure.
                    C94      Action: Use MAP 0210.

                    C95

674-107     D        C95      Description: Interface board wrap test
                             failure.
                    674      Action: Use MAP 0210.

                    C97

674-110     D        C94      Description: Artic960 PCI Adapter Download
                             Diagnostics test failure.
                    674      Action: Use MAP 0210.

                    C95

674-123     D        C95      Description: Interface board non-wrap test
                             failure.
                    C98      Action: Use MAP 0210.

                    C97

674-150     D        674      Description: Device configuration failure.

                  software   Action: Use MAP 0210.

                    227

674-151     D        674      Description: Device driver indicates a
                             hardware failure.
                  software   Action: Use MAP 0210.

                    227

674-152     D        674      Description: Failure and error in
                             determining which type of Artic960 PCI
                             Adapter.
                             Action: Use MAP 0210.
674-153     D        674      Description: Error log analysis indicates
                             a Artic960 PCI Adapter failure.
                    227      Action: Use ERRPT command to check error
                             log.
                    C94

                  software

674-154     D        C94      Description: Artic960 PCI Adapter
                             initialization failure.
                    674      Action: Use MAP 0210.

                    C95

674-155     D        674      Description: Artic960 PCI Adapter
                             initialization failure.
                    C94      Action: Use MAP 0210.

                    C95

674-156     D        C95      Description: Artic960 PCI Adapter
                             initialization failure.
                    674      Action: Use MAP 0210.

                    C94

674-157     D        C98      Description: Cable wrap test failure.
                             Action: Use MAP 0210.
                    C97

                    C95

675-101     D        675      Description: Artic960Hx Adapter Central
                             Processing Unit (CPU) test failure.
                    C94      Action: Use MAP 0210.

                    C95

675-102     D        675      Description: Artic960Hx Adapter Timer test
                             failure.
                    C94      Action: Use MAP 0210.

                    C95

675-103     D        675      Description: Artic960Hx Adapter Bus
                             Interface test failure.
                    C94      Action: Use MAP 0210.

                    C95

675-104     D        C94      Description: Artic960Hx Adapter Dynamic
                             Random Access Memory (DRAM) test failure.
                    675      Action: Use MAP 0210.

                    C95

675-105     D        675      Description: Artic960Hx Adapter Memory
                             Protection test failure.
                    C94      Action: Use MAP 0210.

                    C95

675-106     D        675      Description: Artic960Hx Adapter Debug Port
                             test failure.
                    C94      Action: Use MAP 0210.

                    C95

675-107     D        C95      Description: Interface board wrap test
                             failure.
                    675      Action: Use MAP 0210.

                    C97

675-110     D        C94      Description: Artic960Hx Adapter Download
                             Diagnostics test failure.
                    675      Action: Use MAP 0210.

                    C95

675-123     D        C95      Description: Interface board non-wrap test
                             failure.
                    C98      Action: Use MAP 0210.

                    C97

675-150     D        675      Description: Device configuration failure.

                  software   Action: Use MAP 0210.

                    227

675-151     D        675      Description: Device driver indicates a
                             hardware failure.
                  software   Action: Use MAP 0210.

                    227

675-152     D        675      Description: Failure and error in
                             determining which type of Artic960Hx
                             Adapter.
                             Action: Use MAP 0210.
675-153     D        675      Description: Error log analysis indicates
                             a Artic960Hx Adapter failure.
                    227      Action: Use ERRPT command to check error
                             log.
                    C94

                  software

675-154     D        C94      Description: Artic960Hx Adapter
                             initialization failure.
                    675      Action: Use MAP 0210.

                    C95

675-155     D        675      Description: Artic960Hx Adapter
                             initialization failure.
                    C94      Action: Use MAP 0210.

                    C95

675-156     D        C95      Description: Artic960Hx Adapter
                             initialization failure.
                    675      Action: Use MAP 0210.

                    C94

675-157     D        C98      Description: Cable wrap test failure.
                             Action: Use MAP 0210.
                    C97

                    C95

677-201     D        677      Description: Configuration Register test
                             failure
                    221

677-202     D        677      Description: Reset test failure

                    221

677-203     D        677      Description: Register test failure

                    221

677-204     D        677      Description: SRAM test failure

                    221

677-205     D        677      Description: Interrupt test failure

                    221

677-206     D        677      Description: PCI Loop Back test failure

                    221

677-207     D        677      Description: Internal Loop Back test
                             failure
                    221

677-208     D        677      Description: External Loop Back test
                             failure
                    221

677-209     D        677      Description: Hub Loop Back test failure

                    xxx

677-301     D        677      Description: I/O Error on Read/Write
                             Operation
                    221

                  Software

677-401     F        C24      Description: Unisolated Loop Back test
                             failure
                    xxx      Action: Run diagnostics again utilizing the
                             wrap plug.
                    677

                    221

677-701     G        677      Description: Error log analysis indicates
                             that an error has occurred with the
                    221      adapter.

677-702     G     Microcode   Description: Error log analysis indicates
                             that an adapter microcode error has
                    677      occurred

678-098     J        678      Description: Tape drive indicates an
                             error.
678-099     J        678      Description: Tape drive not found.

                    B88

678-101                        Description: Timeout while attempting to
            D       678      communicate with SCSI device.

                               Description: The SCSI device indicates
678-102     D       678      busy.

678-103                        Description: The SCSI device indicates a
            D       678      reservation conflict.

678-104                        Description: The SCSI device indicates a
            D       678      check condition.

678-105                        Description: An error is detected in
            D       678      request sense data.

678-107                        Description: Sense data from the SCSI
            D       678      drive has unexpected data.

678-110                        Description: The Reserve command failed.
            D       678

678-111                        Description: Invalid condition from the
            D       678      drive after a reserve.

678-112                        Description: The write protect sensor
            D       678      test failed.

678-113                        Description: Invalid condition from drive
            D       678      after a request sense.

678-114                        Description: Timeout while attempting to
            D       678      communicate with the SCSI device.

                               Description: The Inquiry command failed.
678-120     D       678

678-130                        Description: The Load command failed.
            D       678
                   media

678-134                        Description: The adapter failed to
            D       B88      configure.
                  software

678-135                        Description: The Unload command failed.
            D       678
                   media

678-140                        Description: The Mode Select command
            D       678      failed.

678-150                        Description: The Test Unit Ready command
            D       678      failed.
                   media

678-160                        Description: The Send Diagnostic command
            D       678      failed.
                   media

678-161                        Description: Invalid condition from the
            D       678      drive after a reserve.
                    B88

678-163                        Description: Invalid condition from the
            D       678      drive after a request sense.
                    B88

678-164                        Description: Timeout while attempting to
            D       678      communicate with the SCSI device.
                    B88

                               Description: Write, Read and Compare Test
678-165     D       678      failed.
                    B88
                    276

678-166                        Description: Unable to configure the
            D       678      device.
                    B88
                  software

678-167                        Description: An unexpected SCSI error
            D       678      occurred.
                    B88

678-168                        Description: The adapter failed to
            D       B88      configure.
                  software

678-169                        Description: The send diagnostic command
            D       678      failed.
                   media

678-170                        Description: The Read, Write and Compare
            D       678      test failed.
                    B88
                   media

678-180                        Description: The Load command failed.
            D       678
                   media

678-185                        Description: The Unload command failed.
            D       678
                   media

678-190                        Description: The Mode Select command
            D       678      failed.

678-200                        Description: The Test Unit Ready command
            D       678      failed.
                   media

678-201                        Description: Error diagnosed from error
            G       678      log analysis.
                    B88

678-210                        Description: The device configuration
            D       678      failed.
                    B88

678-211                        Description: The device open failed.
            D       678
                    B88

678-220                        Description: The Release command failed.
            D       678

678-230                        Description: The Request Sense command
            D       678      failed.

678-240                        Description: The Openx command failed.
            D       678

678-260                        Description: The device configuration
            D       678      failed.

678-261                        Description: The device open failed.
            D       678

678-300                        Description: The device configuration
            D       678      failed.
                  software

678-310                        Description: SCSI adapter configuration
            D       B88      failed.
                    678
                  software

678-320                        Description: Error log analysis indicates
            G       678      a failure.
                   media

678-411                        Description: A reservation conflict
   to       D       678      occurred.
678-423             B88
                  software

678-511                        Description: The drive returned bad or
   to       D       678      non-extended sense data.
678-523             B88

678-611                        Description: An adapter or bus I/O error
   to       D       678      occurred.
678-623             B88
                  software

678-711                        Description: A device timeout error
   to       D       678      occurred.
678-723             B88
                  software

679-098                        Description: The disk drive indicates an
            J       679      error.
                    B88

679-099                        Description: The disk drive not found.
            J       679
                    B88

679-102                        Description: An unrecoverable media error
            D       679      occurred.

679-104                        Description: The motor failed to restart.
            D       679

679-105                        Description: The drive did not become
            D       679      ready.

679-106                        Description: The electronics card test
            D       679      failed.

679-108                        Description: The bus test failed.
            D       679

679-110                        Description: The media format is
            D       679      corrupted.

679-112                        Description: The diagnostic test failed.
            D       679

679-114                        Description: An unrecoverable hardware
            D       679      error.

679-116                        Description: A protocol error.
            D                Action: Check the levels of the device,
                             adapter, diagnostic software, and
                             application software to be sure they are
                             all compatible. If you do not find a
                             problem, call your support person.
679-117                        Description: A write protect error
            D       679      occurred.

679-118                        Description: A SCSI command time-out
            D       679      occurred.
                    B88

679-120                        Description: A SCSI busy or command
            D       679      error.

679-122                        Description: A SCSI reservation conflict
          D       679      error.

679-124                        Description: A SCSI check condition error
            D       679      occurred.

679-126                        Description: A software error was caused
            D       679      by a hardware failure.
                    B88

679-128                        Description: The error log analysis
            G       679      indicates a hardware failure.

679-129     G        D50      Description: Error log analysis indicates
                             a SCSI bus problem.
                    679

                    B88

                  software

679-130     G        679      Description: Error log analysis indicates
                             a problem reported by the disk drive's self
                             monitoring function.
679-132                        Description: A disk drive hardware error
            D       679      occurred.

679-134                        Description: The adapter failed to
            D       B88      configure.
                  software

679-135     D        679      Description: The device failed to
                    B88      configure.

                  software

679-136                        Description: The certify operation
            D       679      failed. save

679-137     D        679      Description: Unit attention condition has
                             occurred on the Send Diagnostic command.
                    B88

                    D50

681-098     J        681      Description: The disk drive indicates an
                             error.
                    B88

681-099     J        681      Description: The disk drive not found.

                    B88

681-102     D        681      Description: An unrecoverable media error
                             occurred.
681-104     D        681      Description: The motor failed to restart.

681-105     D        681      Description: The drive did not become
                             ready.
681-106     D        681      Description: The electronics card test
                             failed.
681-108     D        681      Description: The bus test failed.

681-110     D        681      Description: The media format is
                             corrupted.
681-112     D        681      Description: The diagnostic test failed.

681-114     D        681      Description: An unrecoverable hardware
                             error.
681-116     D                 Description: A protocol error.
                             Action: Check the levels of the device,
                             adapter, diagnostic software, and
                             application software to be sure they are
                             all compatible. If you do not find a
                             problem, call your support person.
681-117     D        681      Description: A write protect error
                             occurred.
681-118     D        681      Description: A SCSI command time-out
                             occurred.
                    B88

681-120     D        681      Description: A SCSI busy or command error.

681-122     D        681      Description: A SCSI reservation conflict
                             error.
681-124     D        681      Description: A SCSI check condition error
                             occurred.
681-126     D        681      Description: A software error was caused
                             by a hardware failure.
                    B88

681-128     G        681      Description: The error log analysis
                             indicates a hardware failure.
681-129     G        D50      Description: Error log analysis indicates
                             a SCSI bus problem.
                    681

                    B88

                  software

681-130     G        681      Description: Error log analysis indicates
                             a problem reported by the disk drive's self
                             monitoring function.
681-132     D        681      Description: A disk drive hardware error
                             occurred.
681-134     D        B88      Description: The adapter failed to
                             configure.
                  software

681-135     D        681      Description: The device failed to
                             configure.
                    B88

                  software

681-136     D        681      Description: The certify operation failed.

681-137     D        681      Description: Unit attention condition has
                             occurred on the Send Diagnostic command.
                    B88

                    D50

682-098     J        682      Description: IPLROS detected a problem
                             with the CD-ROM drive
                    B88

                    221

682-099     J        682      Description: IPLROS detected a problem
                             with the CD-ROM drive
                    B88

682-111     D        682      Description: Unable to reserve device.

                    B88

682-112     D        682      Description: Unable to do configuration.

                    B88

682-113     D        682      Description: Unable to open the device
                             driver.
                    B88

682-121     D        682      Description: The CD-ROM drive indicates an
                             error.
682-122     D        682      Description: The CD-ROM drive indicates an
                             error.
682-123     D        682      Description: The CD-ROM drive indicates an
                             error.
682-125     D        682      Description: The CD-ROM drive indicates an
                             error.
                    B88

682-126     D        682      Description: The CD-ROM drive indicates an
                             error.
682-127     D        682      Description: The CD-ROM drive indicates an
                             error.
682-128     D        682      Description: The CD-ROM drive indicates an
                             error.
682-129     D        682      Description: The CD-ROM drive indicates an
                             error.
682-150     D       Media     Description: A media error was detected.

                    682

682-151     D        682      Description: A command timeout was
                             detected.
                    D88

682-152     D        682      Description: A command reservation
                             conflict was detected.
682-162     D        682      Description: The CD-ROM drive indicates an
                             error.
682-171     D        682      Description: Unable to reserve device.

682-172     D        682      Description: Unable to do configuration.

682-173     D        682      Description: Unable to open device driver.

682-175     D        682      Description: The CD-ROM drive indicates an
                             error.
682-198     D        682      Description: Undefined error detected.

                    B88

682-199     D        682      Description: Undefined error detected.

682-211     D        682      Description: The LED test failed.

682-281     D        682      Description: No tone during audio test.

682-301     G        682      Description: Errors found during ELA.

682-302     G        682      Description: Errors found during ELA.

                    B88

685-001     D        685      Description: RGB_SCREEN_USER_FAIL

                  Monitor/

                   cable

685-040     D        685      Description: STATUS_POLL_TIMEOUT_ERROR

                    227

                  Monitor/

                   cable

685-041     D        685      Description: CRC_POLL_TIMEOUT_ERROR

                    227

                  Monitor/

                   cable

685-060     D     software    Description: SVC_AIDS_INPUT_ERROR

                    685

685-081     D     software    Description: LOOP_COUNT_WAS_ZERO

                    685

685-082     D     software    Description: INVALID_TU_NUMBER

                    685

685-0B0     D     software    Description: ROM test failed

                    685

685-0B1     D     software    Description: ROM test failed

                    685

685-0D0     D     software    Description: INTERNAL_ERROR_DATA_SIZE_0

                    685

685-0D1     D     software    Description: INTERNAL_ERROR_DATA_SIZE_1

                    685

685-0D2     D     software    Description: INTERNAL_ERROR_DATA_SIZE_2

                    685

685-0D3     D     software    Description: INTERNAL_ERROR_DATA_SIZE_3

                    685

685-0D5     D     software    Description: ODM INIT FAILED

                    685

685-0D6     D     software    Description: ODM_OBJECT_SEARCH_FAILED

                    685

685-0D8     D     software    Description: ODM_GET_OBJECT_FAILED

                    685

685-0D9     D     software    Description: ODM_TERM_FAILED

                    685

685-0DB     D     software    Description: ILLEGAL_RESOLUTION_SPECIFIED

                    685

685-0E5     D     software    Description:
                             AIXGSC_MGA_START_INTERRUPT_FAILED
                    685

685-0E6     D     software    Description:
                             AIXGSC_MGA_STOP_INTERRUPT_FAILED
                    685

685-0E7     D     software    Description: MDD_OPEN_BUS_FAILED

                    685

685-0E8     D     software    Description: MDD_IOCTL_ERROR

                    685

685-0E9     D     software    Description: OPEN_RCM_ERROR

                    685

685-0EA     D     software    Description: IOCTL_GSC_HANDLE_FAILED

                    685

685-0EB     D     software    Description: AIXGSC_MAKE_GP_FAILED

                    685

685-0EC     D     software    Description: AIXGSC_UNMAKE_GP_FAILED

                    685

685-0ED     D     software    Description: DEVICE_BUSY_ERROR

                    685

685-0EE     D     software    Description: AIXGSC_MGA_SET_DISPLAY_FAILED

                    685

685-100     D        685      Description: REG_32_BIT_PRTN_ERROR

                    227

                  Monitor/

                   cable

685-101     D        685      Description: REG_32_BIT_ADDR_UNIQ_ERROR

                    227

                  Monitor/

                   cable

685-102     D        685      Description: REG_8_BIT_PTRN_ERROR

                    227

                  Monitor/

                   cable

685-103     D        685      Description: REG_8_BIT_ADDR_UNIQ_ERROR

                    227

                  Monitor/

                   cable

685-104     D        685      Description: CRTC_REGS_PTRN_ERROR

                    227

                  Monitor/

                   cable

685-105     D        685      Description: CRTC_REGS_ADDR_UNIQ_ERROR

                    227

                  Monitor/

                   cable

685-106     D        685      Description: CRTCEXT_REGS_PTRN_ERROR

                    227

                  Monitor/

                   cable

685-107     D        685      Description: CRTCEXT_REGS_ADDR_UNIQ_ERROR

                    227

                  Monitor/

                   cable

685-108     D        685      Description: RAMDAC_REGS_PTRN_ERROR

                    227

                  Monitor/

                   cable

685-109     D        685      Description: RAMDAC_REGS_ADDR_UNIQ_ERROR

                    227

                  Monitor/

                   cable

685-10A     D        685      Description: PALETTE_REGS_PTRN_ERROR

                    227

                  Monitor/

                   cable

685-10B     D        685      Description: PALETTE_REGS_ADDR_UNIQ_ERROR

                    227

                  Monitor/

                   cable

685-200     D        685      Description: ROM test failed

                    227

685-201     D        685      Description: ROM test failed

                    227

685-202     D        685      Description: ROM test failed

                    227

685-203     D        685      Description: ROM test failed

                    227

685-204     D        685      Description: ROM test failed

                    227

685-205     D        685      Description: ROM test failed

                    227

685-206     D        685      Description: ROM test failed

                    227

685-207     D        685      Description: ROM test failed

                    227

685-208     D        685      Description: ROM test failed

                    227

685-209     D        685      Description: ROM test failed

                    227

685-20B     D        685      Description: ROM test failed

                    227

685-400     D        685      Description: SGRAM_RED_SCREEN_ERROR

                    227

                  Monitor/

                   cable

685-401     D        685      Description: SGRAM_GREEN_SCREEN_ERROR

                    227

                  Monitor/

                   cable

685-402     D        685      Description: SGRAM_BLUE_SCREEN_ERROR

                    227

                  Monitor/

                   cable

685-403     D        685      Description: SGRAM_WHITE_SCREEN_ERROR

                    227

                  Monitor/

                   cable

685-404     D        685      Description:
                             SGRAM_INCREMENTING_SCREEN_ERROR
                    227

                  Monitor/

                   cable

685-500     D        685      Description: BLIT_TEST_ERROR_640 x 480

                    227

                  Monitor/

                   cable

685-501     D        685      Description: BLIT_TEST_ERROR_800 x 600

                    227

                  Monitor/

                   cable

685-502     D        685      Description: BLIT_TEST_ERROR_1024 x 768

                    227

                  Monitor/

                   cable

685-503     D        685      Description: BLIT_TEST_ERROR_1280 x 1024

                    227

                  Monitor/

                   cable

685-504     D     software    Description: INTERNAL_ERROR_DATA_SIZE_4

                    685

685-600     D        685      Description: DRAW_TEST_ERROR_640 x 480_A

                    227

                  Monitor/

                   cable

685-601     D        685      Description: DRAW_TEST_ERROR_800 x 600_A

                    227

                  Monitor/

                   cable

685-602     D        685      Description: DRAW_TEST_ERROR_1024 x 768_A

                    227

                  Monitor/

                   cable

685-603     D        685      Description: DRAW_TEST_ERROR_1280 x 1024_A

                    227

                  Monitor/

                   cable

685-604     D     software    Description: INTERNAL_ERROR_DATA_SIZE_5

                    685

685-605     D        685      Description: DRAW_TEST_ERROR_640 x 480_B

                    227

                  Monitor/

                   cable

685-606     D        685      Description: DRAW_TEST_ERROR_800 x 600_B

                    227

                  Monitor/

                   cable

685-607     D        685      Description: DRAW_TEST_ERROR_1024 x 768_B

                    227

                  Monitor/

                   cable

685-608     D        685      Description: DRAW_TEST_ERROR_1280 x 1024_B

                    227

                  Monitor/

                   cable

685-609     D     software    Description: INTERNAL_ERROR_DATA_SIZE_6

                    685

685-60A     D        685      Description: DRAW_TEST_ERROR_640 x 480_C

                    227

                  Monitor/

                   cable

685-60B     D        685      Description: DRAW_TEST_ERROR_800 x 600_C

                    227

                  Monitor/

                   cable

685-60C     D        685      Description: DRAW_TEST_ERROR_1024 x 768_C

                    227

                  Monitor/

                   cable

685-60D     D        685      Description: DRAW_TEST_ERROR_1280 x 1024_C

                    227

                  Monitor/

                   cable

685-60E     D     software    Description: INTERNAL_ERROR_DATA_SIZE_7

                    685

686-114     D        686      Description: The register verification
                             test failed.
686-124     D        686      Description: The adapter RAM verification
                             test failed.
686-152     D        686      Description: The data wrap communication
                             test failed.

                             Note: The cable could be defective. The
                             cable FRU part number is listed along with
                             the adapter under FFC 686.
686-153     D        686      Description: The modem control line test
                             failed.
686-252     D        686      Description: The data wrap communication
                             test failed.
686-253     D        686      Description: The modem control line test
                             failed.
686-501     D        686      Description: Adapter Reset failed

686-511     D        686      Description: Adapter to host memory test
                             failed (byte tag test)
686-512     D        686      Description: Adapter to host memory test
                             failed (word tag test)
686-513     D        686      Description: Adapter to host memory test
                             failed (byte pattern test)
686-514     D        686      Description: Adapter to host memory test
                             failed (word pattern test)
686-521     D        686      Description: Adapter BIOS POST CPU failed

686-522     D        686      Description: Adapter BIOS POST Checksum
                             failed
686-523     D        686      Description: Adapter BIOS POST Timer
                             failed
686-524     D        686      Description: Adapter BIOS POST RAM failed

686-526     D        686      Description: Adapter BIOS POST Async Ports
                             failed
686-527     D        686      Description: Adapter BIOS Misc. failed

686-528     D        686      Description: Adapter BIOS Reset failed

686-529     D        686      Description: Adapter BIOS Download failed

686-531     D        686      Description: Adapter BIOS Command failed

686-533     D        686      Description: Adapter BIOS Timer test
                             failed
686-534     D        686      Description: Adapter BIOS RAM test failed

686-541     D        686      Description: Port async internal loopback
                             test failed (general)
686-542     D        686      Description: Port async internal loopback
                             test failed (no response from the port)
686-551     D        686      Description: Port async external loopback
                             test failed (general)
686-552     D        686      Description: Port async external loopback
                             test failed (data signals)
686-553     D        686      Description: Port async external loopback
                             test failed (control signals)
686-554     D        686      Description: Port async external loopback
                             test failed (modem signals)
686-555     D        686      Description: Port async external loopback
                             test failed (no response from port)
686-901     D     software    Description: An unexpected error occurred
                             that can be attributed to software or
   to               686      hardware.
                             Action: Run diagnostics from a source other
686-920                      than from the disk or a network. If the
                             same error occurs or if the original SRN
                             was not obtained from disk or a network
                             based diagnostics, use Chapter 12. "MAP
                             0210: General Problem Resolution" with a
                             FFC of 686; otherwise, suspect a software
                             problem.
686-921     D        686      Description: The adapter failed to
                             configure.
                  software

686-922     D     software    Description: An unexpected error occurred
                             that can be attributed to software or
   to               686      hardware.
                             Action: Run diagnostics from a source other
686-924                      than from the disk or a network. If the
                             same error occurs or if the original SRN
                             was not obtained from disk or a network
                             based diagnostics, use Chapter 12. "MAP
                             0210: General Problem Resolution" with a
                             FFC of 686; otherwise, suspect a software
                             problem.
686-925     D        686      Description: The adapter failed to
                             configure. software
686-926     D     software    Description: An unexpected error occurred
                             that can be attributed to software or
   to               686      hardware.
                             Action: Run diagnostics from a source other
686-950                      than from the disk or a network. If the
                             same error occurs or if the original SRN
                             was not obtained from disk or a network
                             based diagnostics, use Chapter 12. "MAP
                             0210: General Problem Resolution" with a
                             FFC of 686; otherwise, suspect a software
                             problem.
687-114     D        687      Description: The register verification
                             test failed.
687-124     D        687      Description: The adapter RAM verification
                             test failed.
687-152     D        687      Description: The data wrap communication
                             test failed.
                    837

                    684

                    152

687-153     D        687      Description: The modem control line test
                             failed.
687-252     D        687      Description: The data wrap communication
                             test failed.
687-253     D        687      Description: The modem control line test
                             failed.
687-144     D        687      Description: The sync line test failed.

687-244     D        687      Description: The sync line test failed.

687-501     D        687      Description: Adapter Reset failed

687-502     D        687      Description: Adapter Fuse failed

687-511     D        687      Description: Adapter to host memory test
                             failed (byte tag test)
687-512     D        687      Description: Adapter to host memory test
                             failed (word tag test)
687-513     D        687      Description: Adapter to host memory test
                             failed (byte pattern test)
687-514     D        687      Description: Adapter to host memory test
                             failed (word pattern test)
687-521     D        687      Description: Adapter BIOS POST CPU failed

687-522     D        687      Description: Adapter BIOS POST Checksum
                             failed
687-523     D        687      Description: Adapter BIOS POST Timer
                             failed
687-524     D        687      Description: Adapter BIOS POST RAM failed

687-525     D        687      Description: Adapter BIOS POST Sync Line
                             failed
687-527     D        687      Description: Adapter BIOS Misc. failed

687-528     D        687      Description: Adapter BIOS Reset failed

687-529     D        687      Description: Adapter BIOS Download failed

687-531     D        687      Description: Adapter BIOS Command failed

687-533     D        687      Description: Adapter BIOS Timer test
                             failed
687-534     D        687      Description: Adapter BIOS RAM test failed

687-541     D        687      Description: Port sync internal loopback
                             test failed
687-551     D        687      Description: Port sync external loopback
                             test failed
687-600     D        837      Description: 232RAN status test failed

687-700     D        684      Description: 422RAN status test failed

687-901     D     software    Description: An unexpected error occurred
                             that can be attributed to software or
   to               687      hardware.
                             Action: Run diagnostics from a source other
687-920                      than from the disk or a network. If the
                             same error occurs or if the original SRN
                             was not obtained from disk or a network
                             based diagnostics, use Chapter 12. "MAP
                             0210: General Problem Resolution" with a
                             FFC of 687; otherwise, suspect a software
                             problem.
687-921     D     software    Description: The adapter failed to
                             configure.
                    687

687-922     D     software    Description: An unexpected error occurred
   to                        that can be attributed to software or
687-924             687      hardware.
                             Action: Run diagnostics from a source other
                             than from the disk or a network. If the
                             same error occurs or if the original SRN
                             was not obtained from disk or a network
                             based diagnostics, use Chapter 12. "MAP
                             0210: General Problem Resolution" with a
                             FFC of 687; otherwise, suspect a software
                             problem.
687-925     D        687      Description: The adapter failed to
                             configure.
                  software

687-926     D     software    Description: An unexpected error occurred
                             that can be attributed to software or
   to               687      hardware.
                             Action: Run diagnostics from a source other
687-950                      than from the disk or a network. If the
                             same error occurs or if the original SRN
                             was not obtained from disk or a network
                             based diagnostics, use Chapter 12. "MAP
                             0210: General Problem Resolution" with a
                             FFC of 687; otherwise, suspect a software
                             problem.
689-098                        Description: The disk drive indicates an
            J       689      error.
                    B88

689-099                        Description: The disk drive not found.
            J       689
                    B88

689-102                        Description: An unrecoverable media error
            D       689      occurred.

689-104                        Description: The motor failed to restart.
            D       689

689-105                        Description: The drive did not become
            D       689      ready.

689-106                        Description: The electronics card test
            D       689      failed.

689-108                        Description: The bus test failed.
            D       689

689-110                        Description: The media format is
            D       689      corrupted.

689-112                        Description: The diagnostic test failed.
            D       689

689-114                        Description: An unrecoverable hardware
            D       689      error.

689-116                        Description: A protocol error.
            D                Action: Check the levels of the device,
                             adapter, diagnostic software, and
                             application software to be sure they are
                             all compatible. If you do not find a
                             problem, call your support person.
689-117                        Description: A write protect error
            D       689      occurred.

689-118                        Description: A SCSI command time-out
            D       689      occurred.
                    B88

689-120                        Description: A SCSI busy or command
            D       689      error.

689-122                        Description: A SCSI reservation conflict
            D       689      error.

689-124                        Description: A SCSI check condition error
            D       689      occurred.

689-126                        Description: A software error was caused
            D       689      by a hardware failure.
                    B88

689-128                        Description: The error log analysis
            G       689      indicates a hardware failure.

689-129     G        D50      Description: Error log analysis indicates
                             a SCSI bus problem.
                    689

                    B88

                  software

689-130     G        689      Description: Error log analysis indicates
                             a problem reported by the disk drive's self
                             monitoring function.
689-132                        Description: A disk drive hardware error
            D       689      occurred.

689-134                        Description: The adapter failed to
            D       B88      configure.
                  software

689-135     D        689      Description: The device failed to
                    B88      configure.

                  software

689-136                        Description: The certify operation
            D       689      failed. save

689-137     D        689      Description: Unit attention condition has
                             occurred on the Send Diagnostic command.
                    B88

                    D50

690-098                        Description: The disk drive indicates an
            J       690      error.
                    B88

690-099                        Description: The disk drive not found.
            J       690
                    B88

690-102                        Description: An unrecoverable media error
            D       690      occurred.

690-104                        Description: The motor failed to restart.
            D       690

690-105                        Description: The drive did not become
            D       690      ready.

690-106                        Description: The electronics card test
            D       690      failed.

690-108                        Description: The bus test failed.
            D       690

690-110                        Description: The media format is
            D       690      corrupted.

690-112                        Description: The diagnostic test failed.
            D       690

690-114                        Description: An unrecoverable hardware
            D       690      error.

690-116                        Description: A protocol error.
            D                Action: Check the levels of the device,
                             adapter, diagnostic software, and
                             application software to be sure they are
                             all compatible. If you do not find a
                             problem, call your support person.
690-117                        Description: A write protect error
            D       690      occurred.

690-118                        Description: A SCSI command time-out
            D       690      occurred.
                    B88

690-120                        Description: A SCSI busy or command
            D       690      error.

690-122                        Description: A SCSI reservation conflict
            D       690      error.

690-124                        Description: A SCSI check condition error
            D       690      occurred.

690-126                        Description: A software error was caused
            D       690      by a hardware failure.
                    B88

690-128                        Description: The error log analysis
            G       690      indicates a hardware failure.

690-129     G        D50      Description: Error log analysis indicates
                             a SCSI bus problem.
                    690

                    B88

                  software

690-130     G        690      Description: Error log analysis indicates
                             a problem reported by the disk drive's self
                             monitoring function.
690-132                        Description: A disk drive hardware error
            D       690      occurred.

690-134                        Description: The adapter failed to
            D       B88      configure.
                  software

690-135     D        690      Description: The device failed to
                    B88      configure.

                  software

690-136     D        690      Description: The certify operation failed.

690-137     D        690      Description: Unit attention condition has
                             occurred on the Send Diagnostic command.
                    B88

                    D50

691-200     D        691      Description: The ATM 25Mbps Adapter open
                             test failed.
                    227

691-202     D        691      Description: The ATM 25Mbps Adapter
                             register test failed.
                    227

691-203     D        691      Description: The ATM 25Mbps Adapter memory
                             test failed.
                    227

691-204     D        691      Description: The ATM 25Mbps Adapter NVRAM
                             test failed.
                    227

691-205     D        691      Description: The ATM 25Mbps Adapter
                             interrupt test failed.
                    227

691-206     D        691      Description: The ATM 25Mbps Adapter wrap
                             test failed.
                    227

691-210     D        691      Description: The ATM 25Mbps Adapter close
                             test failed.
                    227

691-220     D        691      Description: The ATM 25Mbps Adapter was
                             not found.
                    227      Action: Re-install the ATM 25Mbps Adapter
                             and re-run the test. If the error
                             continues, use Chapter 12. "MAP 0210:
                             General Problem Resolution".
691-300     D     Wrap Plug   Description: The ATM 25Mbps Adapter wrap
                             test failed.
                    691      Action: Re-install the wrap plug and re-run
                             the test. If the error continues, use
                    227      Chapter 12. "MAP 0210: General Problem
                             Resolution".
691-700     G        691      Description: Error log analysis reported a
                             hardware error.
                    227

692-110     D        692      Description: The Reserve command failed.

692-120     D        692      Description: The Inquiry command failed.

692-130     D        692      Description: The Load command failed.

                   media

692-135     D        692      Description: The Unload command failed.

                   media

692-140     D        692      Description: The Mode Select command
                             failed.
692-150     D        692      Description: The Test Unit Ready command
                             failed.
                   media

692-160     D        692      Description: The Send Diagnostic command
                             failed.
                   media

692-169     D        692      Description: The send diagnostic command
                             failed.
                   media

692-170     D        692      Description: The Read, Write and Compare
                             test failed.
                    B88

                   media

692-180     D        692      Description: The Load command failed.

                   media

692-185     D        692      Description: The Unload command failed.

                   media

692-190     D        692      Description: The Mode Select command
                             failed.
692-200     D        692      Description: The Test Unit Ready command
                             failed.
                   media

692-210     D        692      Description: The device configuration
                             failed.
                    B88

692-220     D        692      Description: The Release command failed.

692-230     D        692      Description: The Request Sense command
                             failed.
692-240     D        692      Description: The Openx command failed.

692-300     D        692      Description: The device configuration
                             failed.
                  software

692-310     D        B88      Description: SCSI adapter configuration
                             failed.
                    692

                  software

692-320     G        692      Description: Error log analysis indicates
                             a failure.
                   media

692-411     D        692      Description: A reservation conflict
   to                        occurred.
692-423             B88

                  software

692-511     D        692      Description: The drive returned bad or
   to                        non-extended sense data.
692-523             B88

692-611     D        692      Description: An adapter or bus I/O error
   to                        occurred.
692-623             B88

                  software

692-711     D        692      Description: A device timeout error
   to                        occurred.
692-723             B88

                  software

693-100     D        693      Description: Adapter open failed.

                    227

693-101     D        693      Description: Adapter config register test
                             failed.
                    227

693-102     D        693      Description: Adapter reset failed.

                    227

693-103     D        693      Description: Adapter I/O register test
                             failed.
                    227

693-104     D        693      Description: Adapter microcode download
                             test failed.
                    227

693-105     D        693      Description: Adapter internal wrap test
                             failed.
                    227

693-106     D        693      Description: Adapter close failed.

                    227

697-100     D        697      Description: Charm memory write failure

                  software

                    227

697-101     D        697      Description: Charm memory read failure

                  software

                    227

697-102     D        697      Description: PCI configuration register
                             write failure
                  software

                    227

697-103     D        697      Description: Charm software reset failure

                  software

                    227

697-104     D        697      Description: Packet memory error

                  software

                    227

697-105     D        697      Description: Control memory failure

                  software

                    227

697-106     D        697      Description: Link-R detected bad parity

697-107     D        697      Description: Suni detected bad parity

697-108     D        697      Description: Suni initialization failure

697-109     D     Wrap Plug   Description: Loss of light detected in
                             Link test
                    697      Action: Check wrap plug installation.

697-10B     D     Wrap Plug   Description: External Loopback failed
                             Action: Check wrap plug installation.
                    697

697-10C     D        697      Description: Internal Loopback failed

                  software

                    227

697-10D     D        697      Description: DMS failed

                    227

                  software

697-1FF     D        697      Description: EPROM checksum failed

                  software

                    227

697-200     D     software    Description: Klog error

                    697

                    227

697-201     D     software    Description: ASL error

                    697

                    227

697-202     D     software    Description: ODM Initialization error

                    697

                    227

697-203     D     software    Description: Diagnostic configuration
                             failure
                    697

                    227

697-205     D     software    Description: Error in diag open

                    697

                    227

697-206     D     software    Description: Error in releasing adapter

                    697

                    227

698-100     D        698      Description: Charm memory write failure

                  software

                    227

698-101     D        698      Description: Charm memory read failure

                  software

                    227

698-102     D        698      Description: PCI configuration register
                             write failure
                  software

                    227

698-103     D        698      Description: Charm software reset failure

                  software

                    227

698-104     D        698      Description: Packet memory error

                  software

                    227

698-105     D        698      Description: Control memory failure

                  software

                    227

698-106     D        698      Description: Link-R detected bad parity

698-107     D        698      Description: Suni detected bad parity

698-108     D        698      Description: Suni initialization failure

698-109     D     Wrap Plug   Description: Loss of light detected in
                             Link test
                    698      Action: Check wrap plug installation.

698-10B     D     Wrap Plug   Description: External Loopback failed
                             Action: Check wrap plug installation.
                    698

698-10C     D        698      Description: Internal Loopback failed

                  software

                    227

698-10D     D        698      Description: DMS failed

                    227

                  software

698-1FF     D        698      Description: EPROM checksum failed

                  software

                    227

698-200     D     software    Description: Klog error

                    698

                    227

698-201     D     software    Description: ASL error

                    698

                    227

698-202     D     software    Description: ODM Initialization error

                    698

                    227

698-203     D     software    Description: Diagnostic configuration
                             failure
                    698

                    227

698-205     D     software    Description: Error in diag open

                    698

                    227

698-206     D     software    Description: Error in releasing adapter

                    698

                    227

699-100     D        699      Description: An error was found on the
                             adapter
699-110     G        699      Description: Error Log analysis indicates
                             a hardware error.
699-120     D        699      Description: Adapter hardware has caused a
                             software failure.