Service Request Number List for Multiple Bus Systems
Replace FRU parts in the order by which the "Failing Function Codes" are listed. Service Failing Description and Action Request Function (Unless otherwise indicated use Chapter 12. Number Codes "MAP 0210: General Problem Resolution".) SRN Src. 10112 Description: Format Degraded. A Format operation has been ended before it has completed. Action: Refer to the Service Guide for the unit containing the disk drive. 1XXXX Description: Disk drive module error. Action: Refer to the Service Guide for the unit containing the disk drive. Note: In this SRN, an X represents a digit 0 through F. 20PAA Description: An open SSA loop has been detected. Action: Refer to the SSA Adapters: User's Guide and Maintenance Information. 21PAA Description: An SSA 'Threshold exceeded' to link error has been detected. 29PAA Action: Go to the Intermittent Link Error MAP in the SSA Adapters: User's Guide and Maintenance Information. 2A002 Description: Async code 02 has been received. Probably, a software error has occurred. Action: Refer to the user's or service guide for the unit containing the disk drive. 2A003 Description: Async code 03 has been received. Probably, a software error has occurred. Action: Refer to the user's or service guide for the unit containing the disk drive. 2A004 Description: Async code 04 has been received. Probably, a software error has occurred. Action: Refer to the user's or service guide for the unit containing the disk drive. 2A005 Description: Async code 05 has been received. This code indicates that a disk drive module has detected the loss of redundant power or cooling. Action: Refer to the user's or service guide for the unit containing the disk drive. 2A006 Description: Async code 06 has been received. This code indicates that a disk drive module has detected the loss of redundant power or cooling. Action: Refer to the user's or service guide for the unit containing the disk drive. 2A106 Description: Async code 06 has been received. This code indicates that multiple disk drive modules have detected the loss of redundant power or cooling. Action: Refer to the user's or service guide for the unit containing the disk drives. 2A206 Description: A disk drive module has detected that one of its SSA links has failed the POST. Action: Refer to the user's or service guide for the unit containing the disk drive. 2FFFF Description: An async code that is not valid has been received. Action: Refer to the user's or service guide for the unit containing the disk drive. 300C0 Description: A disk drive module has detected the loss of redundant power or cooling. Action: Refer to the user's or service guide for the unit containing the disk drive. 301C0 Description: Multiple disk drive modules have detected the loss of redundant power or cooling. Action: Refer to the user's or service guide for the unit containing the disk drives. 303FF Description: An SCSI status that is not valid has been received. Action: Refer to the SSA Adapters: User's Guide and Maintenance Information. 31000 Description: The disk drive has been reset by the adapter. The disk drive might be going to fail. Action: Refer to the user's or service guide for the unit containing the disk drive. 40000 Description: The SSA adapter card has failed. Action: Refer to the SSA Adapters: User's Guide and Maintenance Information. 40004 Description: A 4MB DRAM module in adapter card slot 0 has failed. Action: Refer to the SSA Adapters: User's Guide and Maintenance Information. 40008 Description: An 8MB DRAM module in adapter card slot 0 has failed. Action: Refer to the SSA Adapters: User's Guide and Maintenance Information. 40016 Description: A 16MB DRAM module in adapter card slot 0 has failed. Action: Refer to the SSA Adapters: User's Guide and Maintenance Information. 40032 Description: A 32MB DRAM module in adapter card slot 0 has failed. Action: Refer to the SSA Adapters: User's Guide and Maintenance Information. 40064 Description: A 64MB DRAM module in adapter card slot 0 has failed. Action: Refer to the SSA Adapters: User's Guide and Maintenance Information. 40128 Description: A 128MB DRAM module in adapter card slot 0 has failed. Action: Refer to the SSA Adapters: User's Guide and Maintenance Information. 41004 Description: A 4MB DRAM module in adapter card slot 1 has failed. Action: Refer to the SSA Adapters: User's Guide and Maintenance Information. 41008 Description: An 8MB DRAM module in adapter card slot 1 has failed. Action: Refer to the SSA Adapters: User's Guide and Maintenance Information. 41016 Description: A 16MB DRAM module in adapter card slot 1 has failed. Action: Refer to the SSA Adapters: User's Guide and Maintenance Information. 41032 Description: A 32MB DRAM module in adapter card slot 1 has failed. Action: Refer to the SSA Adapters: User's Guide and Maintenance Information. 41064 Description: A 64MB DRAM module in adapter card slot 1 has failed. Action: Refer to the SSA Adapters: User's Guide and Maintenance Information. 41128 Description: A 128MB DRAM module in adapter card slot 1 has failed. Action: Refer to the SSA Adapters: User's Guide and Maintenance Information. 42000 Description: The SSA adapter has detected that both DRAM modules are failing. Action: Refer to the SSA Adapters: User's Guide and Maintenance Information. 42200 Description: Other adapters on the SSA loop are using levels of microcode that are not compatible. Action: Refer to the SSA Adapters: User's Guide and Maintenance Information. 42500 Description: An SSA adapter has detected a failure in its fast-write cache. Action: Refer to the SSA Adapters: User's Guide and Maintenance Information. 42510 Description: Not enough DRAM available to run an SSA fast-write cache. Action: Refer to the SSA Adapters: User's Guide and Maintenance Information. 42515 Description: An SSA adapter is attempting to use its fast-write cache, but a fast-write cache card is not installed. Action: Refer to the SSA Adapters: User's Guide and Maintenance Information. 42520 Description: An SSA fast-write cache failure has been detected. Action: Refer to the SSA Adapters: User's Guide and Maintenance Information. 42521 Description: An SSA fast-write cache failure has been detected. Action: Refer to the SSA Adapters: User's Guide and Maintenance Information. 42522 Description: An SSA fast-write cache failure has been detected. Action: Refer to the SSA Adapters: User's Guide and Maintenance Information. 42523 Description: A incorrect version number has been detected in an SSA resource. Action: Refer to the SSA Adapters: User's Guide and Maintenance Information. 42524 Description: An SSA write-cache resource is not available. Action: Refer to the SSA Adapters: User's Guide and Maintenance Information. 42525 Description: An incorrect SSA write-cache resource has been identified. Action: Refer to the SSA Adapters: User's Guide and Maintenance Information. 42526 Description: This adapter does not support the SSA Fast-Write Cache Option. Action: Refer to the SSA Adapters: User's Guide and Maintenance Information. 42527 Description: A dormant SSA fast-write cache entry exists. Action: Refer to the SSA Adapters: User's Guide and Maintenance Information. 42528 Description: A fast-write SSA disk drive has been detected that was previously unsynchronized, but has since been configured on a different adapter. Action: Refer to the SSA Adapters: User's Guide and Maintenance Information. 43PAA Description: An SSA device on the loop is preventing the completion of the loop configuration. Action: Refer to the user's or service guide for the unit containing the device. 44PAA Description: A disk drive module has a 'Failed' status. Action: Refer to the Service Guide for the unit containing the disk drive. 45PAA Description: The SSA adapter has detected an open SSA loop. This problem is caused either by a disk drive module that is failing, or by a disk drive module that has been turned off from another using system on the same SSA loop. (That using system has itself been turned off.) Action: Refer to the user's or service guide for the unit containing the disk drive. 46000 Description: A RAID array is the Offline state because more than one disk drive is not available. At least one member disk drive of the array is present, but more than one member disk drive is missing. Action: Refer to the SSA Adapters: User's Guide and Maintenance Information. 46500 Description: A member disk drive is missing from a SSA array. Action: Refer to the SSA Adapters: User's Guide and Maintenance Information. 47000 Description: An attempt has been made to store in the SSA adapter the details of more than 32 RAID arrays. Action: Refer to the SSA Adapters: User's Guide and Maintenance Information. 47500 Description: Part of the RAID array data might have been lost. Action: Refer to the SSA Adapters: User's Guide and Maintenance Information. 48000 Description: The SSA adapter has detected a link configuration that is not valid. Action: Refer to the SSA Adapters: User's Guide and Maintenance Information. 48600 Description: Member disk drives of an SSA array are not all on the same SSA loop, in a multiple-host-system configuration. Action: Refer to the SSA Adapters: User's Guide and Maintenance Information. 48700 Description: Two or more member disk drives of an SSA array are on different loops. Action: Refer to the SSA Adapters: User's Guide and Maintenance Information. 48800 Description: The SSA RAID strip table is not valid. Action: Refer to the SSA Adapters: User's Guide and Maintenance Information. 48900 Description: An SSA array is not available; a multiple-device error has occurred. Action: Refer to the SSA Adapters: User's Guide and Maintenance Information. 48950 Description: An SSA disk drive has failed during a building operation. Action: Refer to the SSA Adapters: User's Guide and Maintenance Information. 49000 Description: A RAID array is in the Degraded state because a disk drive is not available to the array, and a write command has been sent to that array. Action: Refer to the SSA Adapters: User's Guide and Maintenance Information. 49100 Description: A RAID array is in the Exposed state because a disk drive is not available to the array. Action: Refer to the SSA Adapters: User's Guide and Maintenance Information. 49500 Description: No hot spare disk drives are available for a RAID array that is configured for hot spare disk drives. Action: Refer to the SSA Adapters: User's Guide and Maintenance Information. 49700 Description: The parity for the RAID array is not complete. Action: Refer to the SSA Adapters: User's Guide and Maintenance Information. 4A100 Description: The adapter cannot initialize an SSA disk drive. Action: Refer to the SSA Adapters: User's Guide and Maintenance Information. 4BPAA Description: An SSA disk drive at PAA cannot be configured, because its UID cannot be read. Action: Refer to the SSA Adapters: User's Guide and Maintenance Information. 50000 Description: The SSA adapter failed to respond to the device driver. Action: Refer to the SSA Adapters: User's Guide and Maintenance Information. 50001 Description: A data parity error has occurred. Action: Refer to the SSA Adapters: User's Guide and Maintenance Information. 50002 Description: An SSA adapter DMA error has occurred. Action: Refer to the SSA Adapters: User's Guide and Maintenance Information. 50004 Description: Channel check. Action: Refer to the SSA Adapters: User's Guide and Maintenance Information. 50005 Description: A software error has occurred. Action: Refer to the SSA Adapters: User's Guide and Maintenance Information. 50006 Description: A channel check has occurred. Action: Refer to the SSA Adapters: User's Guide and Maintenance Information. 50007 Description: The IOCC detected an internal error. Action: Refer to the SSA Adapters: User's Guide and Maintenance Information. 50008 Description: Unable to read or write the POS registers. Action: Refer to the SSA Adapters: User's Guide and Maintenance Information. 50010 Description: An SSA adapter or device-driver protocol error has occurred. Action: Refer to the SSA Adapters: User's Guide and Maintenance Information. 50012 Description: The SSA adapter microcode has hung. Action: Refer to the SSA Adapters: User's Guide and Maintenance Information. 50013 Description: The SSA adapter card has failed. Action: Refer to the SSA Adapters: User's Guide and Maintenance Information. 50100 Description: An attempt was made to log an error against a pdisk that is not available to the using system. Action: Refer to the SSA Adapters: User's Guide and Maintenance Information. 50200 Description: Duplicate SSA cluster number detected. Action: Refer to the SSA Adapters: User's Guide and Maintenance Information. 50411 Description: SSA adapter has detected an SS_SIC_CLASS1 error. Action: Refer to the SSA Adapters: User's Guide and Maintenance Information. 50425 Description: SSA adapter has detected an SS_LINK_CONFIG_FAILED error. Action: Refer to the SSA Adapters: User's Guide and Maintenance Information. 504XX Description: The SSA adapter microcode has hung. Action: Refer to the SSA Adapters: User's Guide and Maintenance Information. 60000 Description: The SSA adapter is missing from the expected configuration. Action: Refer to the SSA Adapters: User's Guide and Maintenance Information. 60200 Description: The SSA unit cannot be turned on. Action: Refer to the Service Guide for the unit. 60210 Description: A disk drive module has its Check light on. Action: Refer to the Service Guide for the unit containing the disk drive. 60220 Description: A fan-and-power-supply assembly has its Check light on. Action: Refer to the Service Guide for the unit containing the device that the error was reported against. 60230 Description: The SSA unit has an unexpected Check light on. Action: Refer to the Service Guide for the unit. 60240 Description: An SSA configuration problem has occurred. An SSA device cannot be configured. Action: Refer to the Service Guide for the unit containing the device. 7XXXX Description: An SSA disk drive is missing from the expected configuration of the SSA loop. Action: Refer to the user's or service guide for the unit containing the disk drive. Note: In this SRN, an X represents a digit 0 through F. D0000 Description: The using system cannot configure the disk drive module. Action: Refer to the user's or service guide for the unit containing the disk drive. D0100 Description: Unable to clear a disk drive module reservation. Action: Refer to the user's or service guide for the unit containing the disk drive. D0101 Description: The disk drive module has been reserved since the diagnostics started. Action: Refer to the user's or service guide for the unit containing the disk drive. D0200 Description: The disk drive module timed out while the diagnostics were running. Action: Refer to the user's or service guide for the unit containing the disk drive. D0300 Description: The disk drive module failed the diagnostic test. Action: Refer to the user's or service guide for the unit containing the disk drive. D0400 Description: The disk drive module is not ready while the diagnostics are running. Action: Refer to the user's or service guide for the unit containing the disk drive. D0450 Description: The Format operation that was started on this disk drive module has not yet finished. Action: Refer to the user's or service guide for the unit containing the disk drive. D0460 Description: A Format operation has been degraded. Action: Refer to the user's or service guide for the unit containing the disk drive. D4000 Description: The diagnostics cannot configure the SSA adapter. Action: Refer to the SSA Adapters: User's Guide and Maintenance Information. D4100 Description: The diagnostics cannot open the SSA adapter. Action: Refer to the SSA Adapters: User's Guide and Maintenance Information. D4300 Description: The diagnostics have detected an SSA adapter POST failure. Action: Refer to the SSA Adapters: User's Guide and Maintenance Information. D44XX Description: The diagnostics have detected that the SSA adapter has corrupted the microcode, but cannot download a new version of the microcode. Action: Refer to the SSA Adapters: User's Guide and Maintenance Information. Note: In this SRN, an X represents a digit 0 through F. DFFFF Description: A command or parameter that has been sent or received is not valid. This problem is caused either by the SSA adapter, or by an error in the microcode. Action: Refer to the SSA Adapters: User's Guide and Maintenance Information. 101-000 A Description: The system hung while attempting to configure a device. Action: Use MAP 1540. 101-185 A Description: A checkstop occurred. Action: Use MAP 1540 in the system unit service guide to isolate the cause. 101-517 A Description: The system unit failed to IPL. Action: Use MAP 1540. Description: CD-ROM read problems after 101-518 A boot. Note:The boot record was read from the CD-ROM disk. However, errors occurred when trying to mount the CD-ROM file system. This problem can be caused by SCSI device addressing, SCSI terminator, open PTC, SCSI cable, etc. Action: Go to Chapter 7. "MAP 0050: SCSI Problems Isolation Procedure" Description: The configuration manager 101-521 A detected an error. to Action: If you are running the diagnostics 101-538 from a disk, try running the diagnostics from a CD-ROM. If the diagnostics run correctly from CD-ROM, the problem may be damaged data on the disk. Contact your software support facility. If a different problem occurs when you run the diagnostics from CD ROM, correct that problem. If you were running from a CD ROM at first, or have the same problem on CD ROM that you had when running diagnostics from disk then go to MAP 1540, in either the service guide or the installation and service guide for this system unit. Description: Disk read problems occurred 101-544 A after booting. errors occurred when trying to open the disk drive. This problem can be caused by SCSI device addressing, SCSI terminator, open PTC, SCSI cable, etc. Action: Go to Chapter 7. "MAP 0050: SCSI Problems Isolation Procedure" Description: The system hung while 101-551 A loading the software. This can be caused by to a hardware or software problem. 101-557 Action: Run the diagnostics from CD-ROM. Start at Chapter 4. "MAP 0020: Problem Determination Procedure", Step 14. If the diagnostics run correctly from CD-ROM, the problem may be damaged disk data. Consider having the customer contact Software Support before reinstalling the operating system on the disk. If you still get the same SRN, go to MAP 1540 in either the service guide or the installation and service guide for this system unit. Description: There is not enough memory 101-558 A to execute diagnostics. Action: There must be a minimum of 16MB of installed memory. If the system has 16MB or more of memory installed, suspect a problem with a memory card. 101-559 A Description: The system halted while software was loading. This problem may be to attributed to either hardware or software. Action: Use the CD ROM based diagnostics if 101-599 not yet used. If the same SRN is generated from the CD ROM diagnostics, go to MAP 1540 in the system unit service guide for problem isolation. If the SRN is not generated when using the CD ROM, suspect a problem with the system's software. A xxx Description: The system hung while trying 101-711 to configure an unknown resource. to Action: Run diagnostics from CD-ROM. Start 101-726 at Chapter 4. "MAP 0020: Problem Determination Procedure", Step 14. If you still get the same SRN, refer to "Failing Function Code List" and find the FFC that matches the last three digits of the SRN. Suspect the device adapter or device itself. If more than one adapter or device is installed, isolate the failing resource by removing the adapters or devices one at a time and checking if the system stops with the same value in the three-digit display. Note: xxx corresponds to the last three digits of the SRN. Description: The system hung while trying 101-727 A to configure an asynchronous adapter. Action: Use MAP 1540 in the installation and service guide for this system unit. Suspect a problem with one of the async adapters. 101-7C1 A 7C1 Description: The system unit halted while configuring an audio subsystem. 101-888 A 210 Description: The system does not IPL. Action: Use Chapter 16. "MAP 0260: System 227 Hangs During Resource Configuration". E10 101-c32 D Description: The system hung while indicating that a direct-attached display was selected as the console. Action: Go to MAP 1540 in either the service guide or the installation and service guide for this system unit. Suspect the graphics adapter being used for the display console first. 101-c33 D Description: The system hung while indicating that a TTY terminal is the system console. Action: Go to MAP 1540 in either the service guide or the installation and service guide for this system unit. Suspect the graphics adapter being used for the display console first. 101-xxx A xxx Description: The system hung while configuring a resource. The last three 227 digits identify the failing function code for the resource being configured. Action: Use Chapter 16. "MAP 0260: System Hangs During Resource Configuration". 103-151 D 151 Description: The time-of-day battery failed. 103-202 H Description: Unexpected interrupt. to Action: Go to MAP 1540 in either the 103-210 service guide or the installation and service guide for this system unit. 109-200 B Description: The system crashed while being run by the customer. Action: Use Chapter 4. "MAP 0020: Problem Determination Procedure", and get a new SRN. 110-101 C Description: The diagnostics did not detect an installed resource. Action: If this SRN appeared when running concurrent diagnostics, then run concurrent using the diag -a command, otherwise use Chapter 18. "MAP 0290: Missing Resource Problem Resolution". 110-908 D 908 Description: The system halted while diagnostics were executing. C33 C36 110-921 D Description: The system halted while to xxx diagnostics were executing. 110-926 812 Note: xxx corresponds to the last three digits of the SRN. 110-935 D 935 Description: The system halted while diagnostics were executing. 812 110-946 D 946 Description: The system halted while diagnostics were executing. 221 110-xxx D Description: The system halted while xxx diagnostics were executing. 221 Note: xxx corresponds to the last three digits of the SRN. If your 110 SRN is not listed below, use the 110-xxx procedure. 111-259 B Description: Cannot display readable information on the terminal. Action: Use Chapter 17. "MAP 0280: Boot Problem Resolution" Entry 3. 111-725 B 725 Description: Cannot display readable information on the display. Note: Suspect the display adapter attached to the console display. Action: Use Chapter 17. "MAP 0280: Boot Problem Resolution" 111-736 B 736 Description: The keyboard does not respond. 821 Action: Use Chapter 17. "MAP 0280: Boot Problem Resolution" Entry 1. 111-78C B PCI adapter Description: I/O bus problem. Action: Use Chapter 12. "MAP 0210: General 227 Problem Resolution". E10 Note: PCI adapter refers to the adapters you made note of when using Chapter 11. "MAP 0080 System Bus Problem Isolation". 111-82C B Description: Cannot display readable information on the display. Action: Go to Chapter 17. "MAP 0280: Boot Problem Resolution" Entry 2. 111-922 B 922 Description: The keyboard does not respond. 821 Action: Use Chapter 17. "MAP 0280: Boot Problem Resolution" Entry 1. 111-923 B 923 Description: The keyboard does not respond. 821 Action: Use Chapter 17. "MAP 0280: Boot Problem Resolution" Entry 1. 111-947 B 221 Description: System beeper not functioning correctly. 111-999 D 210 Description: System does not perform a soft reset. 2E6-212 D 2E6 Description: FIFO empty bit set. Action: Go to Chapter 7. "MAP 0050: SCSI 221 Problems Isolation Procedure". 2E6-213 D 2E6 Description: FIFO empty bit clear. Action: Go to Chapter 7. "MAP 0050: SCSI 221 Problems Isolation Procedure". 2E6-214 D 2E6 Description: FIFO full bit set. Action: Go to Chapter 7. "MAP 0050: SCSI 221 Problems Isolation Procedure". 2E6-215 D 2E6 Description: FIFO full bit clear. Action: Go to Chapter 7. "MAP 0050: SCSI 221 Problems Isolation Procedure". 2E6-216 D 2E6 Description: FIFO data miscompare. Action: Go to Chapter 7. "MAP 0050: SCSI 221 Problems Isolation Procedure". 2E6-217 D 2E6 Description: SCSI FIFO data miscompare. Action: Go to Chapter 7. "MAP 0050: SCSI 221 Problems Isolation Procedure". 2E6-218 D 2E6 Description: SCSI FIFO underflow. Action: Go to Chapter 7. "MAP 0050: SCSI 221 Problems Isolation Procedure". 2E6-219 D 2E6 Description: SCSI parity error. Action: Go to Chapter 7. "MAP 0050: SCSI 221 Problems Isolation Procedure". 2E6-220 D 2E6 Description: SCSI FIFO flags error. Action: Go to Chapter 7. "MAP 0050: SCSI 221 Problems Isolation Procedure". 2E6-221 D 2E6 Description: Miscompare during the write/read of the configuration register. 221 Action: Go to Chapter 7. "MAP 0050: SCSI Problems Isolation Procedure". 2E6-222 D 2E6 Description: Error during the write/read of the memory register. 221 Action: Go to Chapter 7. "MAP 0050: SCSI Problems Isolation Procedure". 2E6-223 D 2E6 Description: Miscompare during the write/read of the memory I/O register. 221 Action: Go to Chapter 7. "MAP 0050: SCSI Problems Isolation Procedure". 2E6-224 D 2E6 Description: Error reading the PCI configuration register. 221 2E6-225 D 2E6 Description: Adapter POST failed. 221 2E6-230 D D50 Description: Arbitration test failed. Action: Go to Chapter 7. "MAP 0050: SCSI 2E6 Problems Isolation Procedure". 2E6-231 D D50 Description: Function could not complete. Action: Go to Chapter 7. "MAP 0050: SCSI 2E6 Problems Isolation Procedure". 2E6-232 D D50 Description: SCSI bus data miscompare. Action: Go to Chapter 7. "MAP 0050: SCSI 2E6 Problems Isolation Procedure". 2E6-240 D 2E6 Description: No terminal power. Action: Go to Chapter 7. "MAP 0050: SCSI 221 Problems Isolation Procedure". 2E6-301 D 2E6 Description: Configuration open failed for parent bus. D50 software 2E6-700 G 2E6 Description: Error log analysis indicates a PCI SCSI adapter failure. software 2E6-701 G 2E6 Description: Error log analysis indicates a PCI SCSI adapter failure. software 2E6-702 G 2E6 Description: Error log analysis indicates a PCI SCSI adapter failure. software 2E6-703 G 2E6 Description: Error log analysis indicates a PCI SCSI adapter failure. software 2E6-704 G 2E6 Description: Error log analysis indicates a PCI SCSI adapter failure. software 2E6-705 G 2E6 Description: Error log analysis indicates a PCI SCSI adapter failure. software 2E6-800 G 2E6 Description: Error log analysis indicates a PCI SCSI adapter PTC failure. Action: Go to Chapter 7. "MAP 0050: SCSI Problems Isolation Procedure". 2E6-802 G 2E6 Description: Error log analysis indicates a PCI SCSI bus failure. Action: Go to Chapter 7. "MAP 0050: SCSI Problems Isolation Procedure". 2E7-212 D 2E7 Description: FIFO empty bit set. Action: Go to Chapter 7. "MAP 0050: SCSI 221 Problems Isolation Procedure". 2E7-213 D 2E7 Description: FIFO empty bit clear. Action: Go to Chapter 7. "MAP 0050: SCSI 221 Problems Isolation Procedure". 2E7-214 D 2E7 Description: FIFO full bit set. Action: Go to Chapter 7. "MAP 0050: SCSI 221 Problems Isolation Procedure". 2E7-215 D 2E7 Description: FIFO full bit clear. Action: Go to Chapter 7. "MAP 0050: SCSI 221 Problems Isolation Procedure". 2E7-216 D 2E7 Description: FIFO data miscompare. Action: Go to Chapter 7. "MAP 0050: SCSI 221 Problems Isolation Procedure". 2E7-217 D 2E7 Description: SCSI FIFO data miscompare. Action: Go to Chapter 7. "MAP 0050: SCSI 221 Problems Isolation Procedure". 2E7-218 D 2E7 Description: SCSI FIFO underflow. Action: Go to Chapter 7. "MAP 0050: SCSI 221 Problems Isolation Procedure". 2E7-219 D 2E7 Description: SCSI parity error. Action: Go to Chapter 7. "MAP 0050: SCSI 221 Problems Isolation Procedure". 2E7-220 D 2E7 Description: SCSI FIFO flags error. Action: Go to Chapter 7. "MAP 0050: SCSI 221 Problems Isolation Procedure". 2E7-221 D 2E7 Description: Miscompare during the write/read of the configuration register. 221 Action: Go to Chapter 7. "MAP 0050: SCSI Problems Isolation Procedure". 2E7-222 D 2E7 Description: Error during the write/read of the memory register. 221 Action: Go to Chapter 7. "MAP 0050: SCSI Problems Isolation Procedure". 2E7-223 D 2E7 Description: Miscompare during the write/read of the memory I/O register. 221 Action: Go to Chapter 7. "MAP 0050: SCSI Problems Isolation Procedure". 2E7-224 D 2E7 Description: Error reading the PCI configuration register. 221 2E7-225 D 2E7 Description: Adapter POST failed. 221 2E7-230 D D50 Description: Arbitration test failed. Action: Go to Chapter 7. "MAP 0050: SCSI 2E7 Problems Isolation Procedure". 2E7-231 D D50 Description: Function could not complete. Action: Go to Chapter 7. "MAP 0050: SCSI 2E7 Problems Isolation Procedure". 2E7-232 D D50 Description: SCSI bus data miscompare. Action: Go to Chapter 7. "MAP 0050: SCSI 2E7 Problems Isolation Procedure". 2E7-240 D 2E7 Description: No terminal power. Action: Go to Chapter 7. "MAP 0050: SCSI 221 Problems Isolation Procedure". 2E7-301 D 2E7 Description: Configuration open failed for parent bus. D50 software 2E7-700 G 2E7 Description: Error log analysis indicates a PCI SCSI adapter failure. software 2E7-701 G 2E7 Description: Error log analysis indicates a PCI SCSI adapter failure. software 2E7-702 G 2E7 Description: Error log analysis indicates a PCI SCSI adapter failure. software 2E7-703 G 2E7 Description: Error log analysis indicates a PCI SCSI adapter failure. software 2E7-704 G 2E7 Description: Error log analysis indicates a PCI SCSI adapter failure. software 2E7-705 G 2E7 Description: Error log analysis indicates a PCI SCSI adapter failure. software 2E7-800 G 2E7 Description: Error log analysis indicates a PCI SCSI adapter PTC failure. Action: Go to Chapter 7. "MAP 0050: SCSI Problems Isolation Procedure". 2E7-802 G 2E7 Description: Error log analysis indicates a PCI SCSI bus failure. Action: Go to Chapter 7. "MAP 0050: SCSI Problems Isolation Procedure". 2EF-101 E 751 Description: Post indicates an adapter failure. 650-xxx D 650 Description: Disk drive configuration failed. 651-140 D 165 Description: Operator panel display test failed 221 651-150 D 166 Description: Sensor indicates a fan has failed. 2E0 Action: Use Chapter 13. "MAP 0220 Hot Plug FRU Problem Resolution". 651-151 D 152 Description: Sensor indicates a voltage is outside the normal range. 2E2 Action: Use MAP 1520. 651-152 D 2E1 Description: Sensor indicates an abnormally high internal temperature. Action: Verify that: 1. The room ambient temperature is within the system operating environment. 2. There is unrestricted air flow around the system. 3. All system covers are closed. 4. There are no fan failures. If none of these problems exist, then proceed with Chapter 13. "MAP 0220 Hot Plug FRU Problem Resolution". 651-153 D 152 Description: Sensor indicates a power supply has failed. E19 Action: Use Chapter 13. "MAP 0220 Hot Plug FRU Problem Resolution". 651-159 D Description: Sensor indicates a FRU has failed. Action: Use the physical location code(s) to replace the FRU(s) that are identified on the diagnostics problem report screen. 651-160 D 166 Description: Sensor indicates a fan is turning too slowly. 2E0 Action: Use Chapter 13. "MAP 0220 Hot Plug FRU Problem Resolution". 651-161 D 152 Description: Sensor indicates a voltage is outside the normal range. 2E2 Action: Use MAP 1520. 651-162 D 2E1 Description: Sensor indicates an abnormally high internal temperature. Action: Verify that: 1. The room ambient temperature is within the system operating environment. 2. There is unrestricted air flow around the system. 3. All system covers are closed. 4. There are no fan failures. If none of these problems exist, then proceed with Chapter 13. "MAP 0220 Hot Plug FRU Problem Resolution". 651-163 D 152 Description: Sensor indicates a power supply has failed. E19 Action: Use Chapter 13. "MAP 0220 Hot Plug FRU Problem Resolution". 651-169 D Description: Sensor indicates a FRU has failed Action: Use the physical location codes to replace the FRUs that are identified on the diagnostics problem report screen. 651-170 D Description: Sensor status not available. Action: Contact your support person. 651-171 D Description: Sensor status not available Action: Contact your support person. 651-600 G Description: Uncorrectable memory or unsupported memory. Action: Examine the memory modules and determine if they are supported types. If the modules are supported, then replace the appropriate memory module(s). 651-601 G Description: Missing or bad memory Action: If the installed memory matches the reported memory size, then replace the memory: otherwise, add the missing memory. 651-602 G 2C5 Description: Bad or missing memory Action: Use Chapter 14. "MAP 0240: Memory Problem Resolution". 651-603 G 2C6 Description: Bad or missing memory Action: Use Chapter 14. "MAP 0240: Memory Problem Resolution". 651-608 G D01 Description: Bad L2 Cache 651-609 G D01 Description: Missing L2 Cache 651-610 G 210 Description: CPU internal error 651-611 G 210 Description: CPU internal cache error 651-612 G D01 Description: L2 Cache parity or multi-bit ECC error 651-613 G D01 Description: L2 cache ECC single-bit error 651-614 G 214 Description: Time-out error waiting for memory controller 651-615 G 292 Description: Time-out error waiting for I/O 651-619 G Description: Error log analysis indicates an error detected by the CPU. The error log indicates the following physical FRU location(s) as the probable cause(s). Action: Use the physical location codes to replace the FRUs that are identified on the diagnostics problem report screen. 651-620 G 2C5 Description: ECC correctable error Action: Use Chapter 14. "MAP 0240: Memory Problem Resolution". 651-621 G 2C6 Description: ECC correctable error Action: Use Chapter 14. "MAP 0240: Memory Problem Resolution". 651-622 G 2C5 Description: Correctable error threshold exceeded Action: Use Chapter 14. "MAP 0240: Memory Problem Resolution". 651-623 G 2C6 Description: Correctable error threshold exceeded Action: Use Chapter 14. "MAP 0240: Memory Problem Resolution". 651-624 G 214 Description: Memory controller internal error 651-625 G 214 Description: Memory Address (Bad address going to memory) 651-626 G 214 Description: Memory Data error (Bad data going to memory) 651-627 G 214 Description: Memory time-out error 651-628 G 210 Description: Processor time-out error 651-629 G Description: Error log analysis indicates and error detected by the memory controller. The error log indicates the following physical FRU location(s) as the probable cause(s). Action: Use the physical location codes to replace the FRUs that are identified on the diagnostics problem report screen. 651-630 G 307 Description: I/O Expansion Bus Parity Error. 651-631 G 307 Description: I/O Expansion Bus Time-out Error. 651-632 G 306 Description: Internal Device Error. 307 308 651-633 G 307 Description: I/O Expansion Unit not in an operating state. 306 651-634 G 307 Description: Internal Device Error. 651-639 G Description: Error log analysis indicates an error detected by the I/O. The error log indicates the following physical FRU location(s) as the probable cause(s). Action: Use the physical location codes to replace the FRUs that are identified on the diagnostics problem report screen. 651-640 G 2D5 Description: I/O general bus error. 651-641 G 2D6 Description: Secondary I/O general bus error 651-642 G 2D3 Description: Internal Service Processor memory error 651-643 G 2D3 Description: Internal Service Processor firmware error 651-644 G 2D3 Description: Other internal Service Processor hardware error 651-650 G E17 Description: ECC correctable error. Action: Use Chapter 14. "MAP 0240: Memory Problem Resolution". 651-651 G E18 Description: ECC correctable error. Action: Use Chapter 14. "MAP 0240: Memory Problem Resolution". 651-652 G 300 Description: ECC correctable error. Action: Use Chapter 14. "MAP 0240: Memory Problem Resolution". 651-653 G 301 Description: ECC correctable error. Action: Use Chapter 14. "MAP 0240: Memory Problem Resolution". 651-654 G 302 Description: ECC correctable error. Action: Use Chapter 14. "MAP 0240: Memory Problem Resolution". 651-655 G 303 Description: ECC correctable error. Action: Use Chapter 14. "MAP 0240: Memory Problem Resolution". 651-656 G 304 Description: ECC correctable error. Action: Use Chapter 14. "MAP 0240: Memory Problem Resolution". 651-657 G 305 Description: ECC correctable error. Action: Use Chapter 14. "MAP 0240: Memory Problem Resolution". 651-660 G E17 Description: Correctable error threshold exceeded. Action: Use Chapter 14. "MAP 0240: Memory Problem Resolution". 651-661 G E18 Description: Correctable error threshold exceeded. Action: Use Chapter 14. "MAP 0240: Memory Problem Resolution". 651-662 G 300 Description: Correctable error threshold exceeded. Action: Use Chapter 14. "MAP 0240: Memory Problem Resolution". 651-663 G 301 Description: Correctable error threshold exceeded. Action: Use Chapter 14. "MAP 0240: Memory Problem Resolution". 651-664 G 302 Description: Correctable error threshold exceeded. Action: Use Chapter 14. "MAP 0240: Memory Problem Resolution". 651-665 G 303 Description: Correctable error threshold exceeded. Action: Use Chapter 14. "MAP 0240: Memory Problem Resolution". 651-666 G 304 Description: Correctable error threshold exceeded. Action: Use Chapter 14. "MAP 0240: Memory Problem Resolution". 651-667 G 305 Description: Correctable error threshold exceeded. Action: Use Chapter 14. "MAP 0240: Memory Problem Resolution". 651-670 G E17 Description: Bad or missing memory. Action: Use Chapter 14. "MAP 0240: Memory Problem Resolution". 651-671 G E18 Description: Bad or missing memory. Action: Use Chapter 14. "MAP 0240: Memory Problem Resolution". 651-672 G 300 Description: Bad or missing memory. Action: Use Chapter 14. "MAP 0240: Memory Problem Resolution". 651-673 G 301 Description: Bad or missing memory. Action: Use Chapter 14. "MAP 0240: Memory Problem Resolution". 651-674 G 302 Description: Bad or missing memory. Action: Use Chapter 14. "MAP 0240: Memory Problem Resolution". 651-675 G 303 Description: Bad or missing memory. Action: Use Chapter 14. "MAP 0240: Memory Problem Resolution". 651-676 G 304 Description: Bad or missing memory. Action: Use Chapter 14. "MAP 0240: Memory Problem Resolution". 651-677 G 305 Description: Bad or missing memory. Action: Use Chapter 14. "MAP 0240: Memory Problem Resolution". 651-710 G 214 Description: Address/Data parity error on Processor bus 2C4 651-711 G 214 Description: Address/Data parity error on Processor bus 210 2C4 651-712 G 214 Description: Address/Data parity error on Processor bus 210 210 2C4 651-713 G 214 Description: Transfer error on Processor bus 2C4 651-714 G 214 Description: Transfer error on Processor bus 210 2C4 651-715 G 214 Description: Transfer error on Processor bus 210 210 2C4 651-720 G 2C5 Description: Uncorrectable Memory Error Action: Use Chapter 14. "MAP 0240: Memory 2C7 Problem Resolution". 214 651-721 G 2C6 Description: Uncorrectable Memory Error Action: Use Chapter 14. "MAP 0240: Memory 2C7 Problem Resolution". 214 651-722 G 210 Description: Processor bus parity error 2C4 214 651-723 G 210 Description: Processor bus parity error 2C4 214 651-724 G 292 Description: I/O Host Bridge time-out error 2C8 214 763 651-725 G 292 Description: I/O Host Bridge address/data parity error 2C8 214 763 651-730 G Description: I/O error on the ISA bus. Action: Refer to the Bus SRN to FRU Reference Table in the system unit's service guide. 651-731 G 2C8 Description: Intermediate or System Bus Address Parity Error. 292 763 651-732 G 2C8 Description: Intermediate or System Bus Data Parity Error. 292 763 651-733 G 214 Description: Intermediate or System Bus Address Parity Error. 2C8 292 651-734 G 214 Description: Intermediate or System Bus Data Parity Error. 2C8 292 651-735 G 2D2 Description: Intermediate or System Bus Time-out Error. 292 651-736 G 2D2 Description: Intermediate or System Bus Time-out Error. 292 214 651-740 G 2D3 Description: Time-out on communication response from Service Processor 2D4 651-741 G 2D3 Description: Service Processor error accessing special registers 2D4 651-742 G 2D3 Description: Service Processor reports unknown communication error 2D4 651-743 G 2D7 Description: Service Processor error accessing Vital Product Data EEPROM 2D5 651-744 G 165 Description: Service Processor error accessing Operator Panel 2D5 2D3 651-745 G 2D9 Description: Service Processor error accessing Power Controller 2D5 651-746 G 2E0 Description: Service Processor error accessing Fan Sensor 2D5 651-747 G 2E1 Description: Service Processor error accessing Thermal Sensor 2D5 651-748 G 2E2 Description: Service Processor error accessing Voltage Sensor 2D5 651-749 G 2E3 Description: Service Processor error accessing Serial Port 2D4 651-750 G 814 Description: Service Processor error accessing NVRAM 2D4 651-751 G 817 Description: Service Processor error accessing Real-Time Clock/Time-of-Day Clock 2D4 651-752 G 2E4 Description: Service Processor error accessing JTAG/COP controller/hardware 2D4 651-753 G 151 Description: Service Processor detects loss of voltage from the Time-of-Day Clock 2D4 backup battery 651-760 G software Description: Service Processor caused a reboot of the system due to a surveillance hardware time-out. Action: A surveillance time-out is caused by lack of response from the operating system. The most likely cause is a software or operating system failure. Verify that the problem is not related to hardware by running diagnostics, in Problem Determination Mode, on all resources which have not already been run. Also, the system administrator should look for other symptoms that would indicate a software or operating system problem. Contact the software support structure for assistance in needed. 651-770 G 2C8 Description: Intermediate or System Bus Address Parity Error. 292 306 651-771 G 2C8 Description: Intermediate or System Bus Data Parity Error. 292 306 651-772 G 2D2 Description: Intermediate or System Bus Time-out Error. 292 306 651-773 G 227 Description: Intermediate or System Bus Data Parity Error. 651-780 G E17 Description: Uncorrectable Memory Error. Action: Use Chapter 14. "MAP 0240: Memory 2C7 Problem Resolution". 214 651-781 G E18 Description: Uncorrectable Memory Error. Action: Use Chapter 14. "MAP 0240: Memory 2C7 Problem Resolution". 214 651-782 G 300 Description: Uncorrectable Memory Error. Action: Use Chapter 14. "MAP 0240: Memory 214 Problem Resolution". 651-783 G 301 Description: Uncorrectable Memory Error. Action: Use Chapter 14. "MAP 0240: Memory 214 Problem Resolution". 651-784 G 302 Description: Uncorrectable Memory Error. Action: Use Chapter 14. "MAP 0240: Memory 214 Problem Resolution". 651-785 G 303 Description: Uncorrectable Memory Error. Action: Use Chapter 14. "MAP 0240: Memory 214 Problem Resolution". 651-786 G 304 Description: Uncorrectable Memory Error. Action: Use Chapter 14. "MAP 0240: Memory 214 Problem Resolution". 651-787 G 305 Description: Uncorrectable Memory Error. Action: Use Chapter 14. "MAP 0240: Memory 214 Problem Resolution". 651-800 G 166 Description: Fan is turning slower than expected 2E0 651-801 G 166 Description: Over voltage condition was detected 2E0 Action: Verify the following: * nothing is obstructing the fan rotation * the fan power connection is tight * the fan speed sensing cable is tight If the fan still is not turning replace the fan. If the fan is turning, replace the fan sensor FRU. 651-810 G 152 Description: Over voltage condition was detected 2E2 Action: Verify that all DC voltages are within specifications. If all of the voltages are within specifications, replace the voltage sensor FRU, otherwise replace the power supply FRU. 651-811 G 152 Description: Under voltage condition was detected 2E2 Action: Verify that all DC voltages are within specifications. If all of the voltages are within specifications, replace the voltage sensor FRU, otherwise replace the power supply FRU. 651-812 G 152 Description: System shutdown due to: 1. Loss of AC power 2. Power button was pushed without proper system shutdown 3. Power supply failure Action: If reasons 1 and 2 can be ruled out than replace the power supply FRU. 651-813 G Description: System shutdown due to loss of AC Power to the site. Action: System resumed normal operation, no action required. 651-814 G 152 Description: CEC Rack shutdown due to one of the following: 1. Loss of AC power to the CEC Rack 2. Open or disconnected SPCN cable between racks 3. AC module, Bulk power, regulator or SPCN card failure. Action: If 1 and 2 can be ruled out and the problem can be recreated, try the power supply related FRUs one at a time to isolate the problem. 651-815 G 287 Description: I/O Rack shutdown due to one of the following: 289 1. Loss of AC power to the I/O Rack 2. Open or disconnected SPCN cable between racks 3. Power supply failure Action: If 1 and 2 can be ruled out, then replace the power supply FRU. 651-816 G 287 Description: Power fault due to internal power supply failure. 651-817 G 289 Description: Power fault due to internal power supply failure. 651-818 G Description: Power fault due to manual activation of power-off request. Action: Resume normal operation. 651-820 G 2E1 Description: An over temperature condition was detected Action: Verify the following: * the room ambient temperature is within the system operating environment * there is unrestricted air flow around the system * all system covers are closed If all conditions are met, then replace the temperature sensor FRU. 651-821 G 2E1 Description: System shutdown due to an over maximum temperature condition being reached. Action: Verify the following: * The room ambient temperature is within the system operating environment. * There is unrestricted air flow around the system. * All system covers are closed. If all conditions are met, then replace the temperature sensor FRU. 651-822 G 166 Description: System shutdown due to over temperature condition and fan failure. Use 2E1 the physical FRU location(s) as the probable cause(s). Action: Use the physical location codes to replace the FRUs that are identified on the diagnostics problem report screen. 651-830 G 166 Description: Sensor detected a fan failure. 2E0 Action: Use Chapter 13. "MAP 0220 Hot Plug FRU Problem Resolution". 651-831 G 152 Description: Sensor detected a voltage outside of the normal range. 2E2 Action: Use MAP 1520. 651-832 G 2E1 Description: Sensor detected an abnormally high internal temperature. Action: Verify that: 1. The room ambient temperature is within the system operating environment. 2. There is unrestricted air flow around the system. 3. All system covers are closed. 4. There are no fan failures. If none of these problems exist, then proceed with Chapter 13. "MAP 0220 Hot Plug FRU Problem Resolution". 651-833 G 152 Description: Sensor detected a power supply failure. E19 Action: Use Chapter 13. "MAP 0220 Hot Plug FRU Problem Resolution". 651-839 G Description: Sensor detected a FRU that has failed. Action: Use the physical location code(s) to replace the FRU(s) that are identified on the diagnostics problem report screen. 651-840 G 166 Description: Sensor detected a fan failure. 2E0 Action: Use Chapter 13. "MAP 0220 Hot Plug FRU Problem Resolution". 651-841 G 152 Description: Sensor detected a voltage outside of the normal range. 2E2 Action: Use MAP 1520. 651-842 G 2E1 Description: Sensor detected an abnormally high internal temperature. Action: Verify that: 1. The room ambient temperature is within the system operating environment. 2. There is unrestricted air flow around the system. 3. All system covers are closed. 4. There are no fan failures. If none of these problems exist, then proceed with Chapter 13. "MAP 0220 Hot Plug FRU Problem Resolution". 651-843 G 152 Description: Sensor detected a power supply failure. E19 Action: Use Chapter 13. "MAP 0220 Hot Plug FRU Problem Resolution". 651-849 G Description: Sensor detected a FRU that has failed. Action: Use the physical location code(s) to replace the FRU(s) that are identified on the diagnostics problem report screen. 651-88x G Description: The CEC or SPCN reported an error. Action: If reference and location codes were reported with this SRN, refer to this system unit's system service guide with the reference and location codes for the necessary repair action. If the reference and location codes were NOT reported, then run Diagnostics in Problem Determination mode and record and report the reference and location codes for this SRN. 651-89x G Description: The CEC or SPCN reported an error. Action: Refer to the this system unit's system service guide, with the reference and location codes, for the necessary repair action. If the reference and location codes were NOT reported, then run Advanced Diagnostics in Problem Determination mode and record and report the reference and location codes for this SRN. 652-600 G Description: A non-critical error has been detected and corrected: Uncorrectable memory or unsupported memory. Action: Schedule deferred maintenance. Examine the memory modules and determine if they are supported types. If the modules are supported, then replace the appropriate memory module(s). 652-610 G 210 Description: A non-critical error has been detected and corrected: CPU internal error. Action: Schedule deferred maintenance. Use Chapter 12. "MAP 0210: General Problem Resolution". 652-611 G 210 Description: A non-critical error has been detected and corrected: CPU internal cache error. Action: Schedule deferred maintenance. Use Chapter 12. "MAP 0210: General Problem Resolution" 652-612 G D01 Description: A non-critical error has been detected and corrected: L2 cache parity or multi-bit ECC error. Action: Schedule deferred maintenance. Use Chapter 12. "MAP 0210: General Problem Resolution". 652-613 G D01 Description: A non-critical error has been detected and corrected: L2 cache ECC single-bit error. Action: Schedule deferred maintenance. Use Chapter 12. "MAP 0210: General Problem Resolution" 652-622 G 2C5 Description: A non-critical error has been detected and corrected: Correctable error threshold exceeded. Action: Schedule deferred maintenance. Use Chapter 14. "MAP 0240: Memory Problem Resolution". 652-623 G 2C6 Description: A non-critical error has been detected and corrected: Correctable error threshold exceeded. Action: Schedule deferred maintenance. Use Chapter 14. "MAP 0240: Memory Problem Resolution". 652-630 G 307 Description: A non-critical error has been detected and corrected: I/O Expansion Bus Parity Error. Action: Schedule deferred maintenance. Use Chapter 12. "MAP 0210: General Problem Resolution". 652-631 G 307 Description: A non-critical error has been detected and corrected: I/O Expansion Bus Time-out Error. Action: Schedule deferred maintenance. Use Chapter 12. "MAP 0210: General Problem Resolution". 652-632 G 306 Description: A non-critical error has been detected and corrected: I/O Expansion Bus 307 Connection Failure. Action: Schedule deferred maintenance. Use 308 Chapter 12. "MAP 0210: General Problem Resolution". 652-633 G 307 Description: A non-critical error has been detected and corrected: I/O Expansion Unit 306 not in an operating state. Action: Schedule deferred maintenance. Use Chapter 12. "MAP 0210: General Problem Resolution". 652-634 G 307 Description: A non-critical error has been detected and corrected: Internal Device Error. Action: Schedule deferred maintenance. Use Chapter 12. "MAP 0210: General Problem Resolution". 652-660 G E17 Description: A non-critical error has been detected and corrected: Correctable error threshold exceeded. Action: Schedule deferred maintenance. Use Chapter 14. "MAP 0240: Memory Problem Resolution". 652-661 G E18 Description: A non-critical error has been detected and corrected: Correctable error threshold exceeded. Action: Schedule deferred maintenance. Use Chapter 14. "MAP 0240: Memory Problem Resolution". 652-662 G 300 Description: A non-critical error has been detected and corrected: Correctable error threshold exceeded. Action: Schedule deferred maintenance. Use Chapter 14. "MAP 0240: Memory Problem Resolution". 652-663 G 301 Description: A non-critical error has been detected and corrected: Correctable error threshold exceeded. Action: Schedule deferred maintenance. Use Chapter 14. "MAP 0240: Memory Problem Resolution". 652-664 G 302 Description: A non-critical error has been detected and corrected: Correctable error threshold exceeded. Action: Schedule deferred maintenance. Use Chapter 14. "MAP 0240: Memory Problem Resolution". 652-665 G 303 Description: A non-critical error has been detected and corrected: Correctable error threshold exceeded. Action: Schedule deferred maintenance. Use Chapter 14. "MAP 0240: Memory Problem Resolution". 652-666 G 304 Description: A non-critical error has been detected and corrected: Correctable error threshold exceeded. Action: Schedule deferred maintenance. Use Chapter 14. "MAP 0240: Memory Problem Resolution". 652-667 G 305 Description: A non-critical error has been detected and corrected: Correctable error threshold exceeded. Action: Schedule deferred maintenance. Use Chapter 14. "MAP 0240: Memory Problem Resolution". 652-731 G 2C8 Description: A non-critical error has been detected and corrected: Intermediate or 292 System Bus Address Parity Error. Action: Schedule deferred maintenance. Use Chapter 12. "MAP 0210: General Problem Resolution". 652-732 G 2C8 Description: A non-critical error has been detected and corrected: Intermediate or 292 System Bus Data Parity Error. Action: Schedule deferred maintenance. Use Chapter 12. "MAP 0210: General Problem Resolution". 652-733 G 214 Description: A non-critical error has been detected and corrected: Intermediate or 2C8 System Bus Address Parity Error. Action: Schedule deferred maintenance. Use 292 Chapter 12. "MAP 0210: General Problem Resolution". 652-734 G 214 Description: A non-critical error has been detected and corrected: Intermediate or 2C8 System Bus Data Parity Error. Action: Schedule deferred maintenance. Use 292 Chapter 12. "MAP 0210: General Problem Resolution". 652-735 G 2D2 Description: A non-critical error has been detected and corrected: Intermediate or 292 System Bus Time-out Error. Action: Schedule deferred maintenance. Use Chapter 12. "MAP 0210: General Problem Resolution". 652-736 G 2D2 Description: A non-critical error has been detected and corrected: Intermediate or 292 System Bus Time-out Error. Action: Schedule deferred maintenance. Use 214 Chapter 12. "MAP 0210: General Problem Resolution". 652-770 G 2C8 Description: A non-critical error has been detected and corrected: Intermediate System 292 Bus Address Parity Error. Action: Schedule deferred maintenance. Use 306 Chapter 12. "MAP 0210: General Problem Resolution". 652-771 G 2C8 Description: A non-critical error has been detected and corrected: Intermediate or 292 System Bus Data Parity Error. Action: Schedule deferred maintenance. Use 306 Chapter 12. "MAP 0210: General Problem Resolution". 652-772 G 2D2 Description: A non-critical error has been detected and corrected: Intermediate or 292 System Bus Time-out Error. Action: Schedule deferred maintenance. Use 306 Chapter 12. "MAP 0210: General Problem Resolution". 652-773 G 227 Description: A non-critical error has been detected and corrected. Intermediate or System Bus Data Parity Error. Action: Schedule deferred maintenance. Use Chapter 12. "MAP 0210: General Problem Resolution". 652-810 G 152 Description: Non-critical power problem, loss of redundant supply. Use the physical FRU location(s) as the probable cause(s). Action: Schedule maintenance. Use the physical location codes to replace the FRUs that are identified on the diagnostics problem report screen. 652-820 G 166 Description: Non-critical cooling problem, loss of redundant fan. Use the physical FRU location(s) as the probable cause(s). Action: Schedule maintenance. Use the physical location codes to replace the FRUs that are identified on the diagnostics problem report screen. 652-830 G 166 Description: Sensor detected a redundant fan failure. 2E0 Action: Use Chapter 13. "MAP 0220 Hot Plug FRU Problem Resolution". 652-833 G 152 Description: Sensor detected a redundant power supply failure. E19 Action: Use Chapter 13. "MAP 0220 Hot Plug FRU Problem Resolution". 652-839 G Description: Sensor detected a redundant FRU failure. Action: Use the physical location code(s) to replace the FRU(s) that are identified on the diagnostics problem report screen. 652-88x G Description: The CEC or SPCN reported a non-critical error. Action: Schedule deferred maintenance. If reference and location codes were reported with this SRN, refer to this system unit's system service guide with the reference and location codes for the necessary repair action. If the reference and location codes were NOT reported, then run Diagnostics in Problem Determination mode and record and report the reference and location codes for this SRN. 652-89x G Description: The CEC or SPCN reported a non-critical error. Action: Schedule deferred maintenance. Refer to the this system unit's system service guide, with the reference and location codes, for the necessary repair action. If the reference and location codes were NOT reported, then run Advanced Diagnostics in Problem Determination mode and record and report the reference and location codes for this SRN. 664-098 J 664 Description: IPLROS detected a problem with the CD-ROM drive B88 221 664-099 J 664 Description: IPLROS detected a problem with the CD-ROM drive B88 664-111 D 664 Description: Unable to reserve device. B88 664-112 D 664 Description: Unable to do configuration. B88 664-113 D 664 Description: Unable to open the device driver. B88 664-121 D 664 Description: The CD-ROM drive indicates an error. 664-122 D 664 Description: The CD-ROM drive indicates an error. 664-123 D 664 Description: The CD-ROM drive indicates an error. 664-125 D 664 Description: The CD-ROM drive indicates an error. B88 664-126 D 664 Description: The CD-ROM drive indicates an error. 664-127 D 664 Description: The CD-ROM drive indicates an error. 664-128 D 664 Description: The CD-ROM drive indicates an error. 664-129 D 664 Description: The CD-ROM drive indicates an error. 664-150 D Media Description: A media error was detected. 664 664-151 D 664 Description: A command timeout was detected. D88 664-152 D 664 Description: A command reservation conflict was detected. 664-162 D 664 Description: The CD-ROM drive indicates an error. 664-171 D 664 Description: Unable to reserve device. 664-172 D 664 Description: Unable to do configuration. 664-173 D 664 Description: Unable to open device driver. 664-175 D 664 Description: The CD-ROM drive indicates an error. 664-198 D 664 Description: Undefined error detected. B88 664-199 D 664 Description: Undefined error detected. 664-211 D 664 Description: The LED test failed. 664-281 D 664 Description: No tone during audio test. 664-301 G 664 Description: Errors found during ELA. 664-302 G 664 Description: Errors found during ELA. B88 669-201 D 669 Description: Configuration register test failure 221 669-202 D 669 Description: I/O register test failure 221 669-203 D 669 Description: Adapter memory test failure 221 669-204 D 669 Description: Adapter initialization test failure 221 669-205 D 669 Description: Internal loopback test failure 221 669-206 D 669 Description: External loopback test failure 221 669-701 G 669 Description: Error log analysis indicates that this device failed to initialize because it is not the IBM version of the adapter. AIX cannot configure the non-IBM version of this adapter 669-702 G 669 Description: Error Log Analysis indicates that this device failed to initialize due 221 to a problem with the EEPROM on the adapter. 669-703 G 669 Description: Error Log Analysis indicates that this device has failed to initialize 221 due to a self-test failure. 669-704 D 669 Description: Error Log Analysis indicates that this device has failed to initialize 221 due to firmware download error. The microcode seems to be properly installed. 674-101 D 674 Description: Artic960 PCI Adapter Central Processing Unit (CPU) test failure. C94 Action: Use MAP 0210. C95 674-102 D 674 Description: Artic960 PCI Adapter Timer test failure. C94 Action: Use MAP 0210. C95 674-103 D 674 Description: Artic960 PCI Adapter Bus Interface test failure. C94 Action: Use MAP 0210. C95 674-104 D C94 Description: Artic960 PCI Adapter Dynamic Random Access Memory (DRAM) test failure. 674 Action: Use MAP 0210. C95 674-105 D 674 Description: Artic960 PCI Adapter Memory Protection test failure. C94 Action: Use MAP 0210. C95 674-106 D 674 Description: Artic960 PCI Adapter Debug Port test failure. C94 Action: Use MAP 0210. C95 674-107 D C95 Description: Interface board wrap test failure. 674 Action: Use MAP 0210. C97 674-110 D C94 Description: Artic960 PCI Adapter Download Diagnostics test failure. 674 Action: Use MAP 0210. C95 674-123 D C95 Description: Interface board non-wrap test failure. C98 Action: Use MAP 0210. C97 674-150 D 674 Description: Device configuration failure. software Action: Use MAP 0210. 227 674-151 D 674 Description: Device driver indicates a hardware failure. software Action: Use MAP 0210. 227 674-152 D 674 Description: Failure and error in determining which type of Artic960 PCI Adapter. Action: Use MAP 0210. 674-153 D 674 Description: Error log analysis indicates a Artic960 PCI Adapter failure. 227 Action: Use ERRPT command to check error log. C94 software 674-154 D C94 Description: Artic960 PCI Adapter initialization failure. 674 Action: Use MAP 0210. C95 674-155 D 674 Description: Artic960 PCI Adapter initialization failure. C94 Action: Use MAP 0210. C95 674-156 D C95 Description: Artic960 PCI Adapter initialization failure. 674 Action: Use MAP 0210. C94 674-157 D C98 Description: Cable wrap test failure. Action: Use MAP 0210. C97 C95 675-101 D 675 Description: Artic960Hx Adapter Central Processing Unit (CPU) test failure. C94 Action: Use MAP 0210. C95 675-102 D 675 Description: Artic960Hx Adapter Timer test failure. C94 Action: Use MAP 0210. C95 675-103 D 675 Description: Artic960Hx Adapter Bus Interface test failure. C94 Action: Use MAP 0210. C95 675-104 D C94 Description: Artic960Hx Adapter Dynamic Random Access Memory (DRAM) test failure. 675 Action: Use MAP 0210. C95 675-105 D 675 Description: Artic960Hx Adapter Memory Protection test failure. C94 Action: Use MAP 0210. C95 675-106 D 675 Description: Artic960Hx Adapter Debug Port test failure. C94 Action: Use MAP 0210. C95 675-107 D C95 Description: Interface board wrap test failure. 675 Action: Use MAP 0210. C97 675-110 D C94 Description: Artic960Hx Adapter Download Diagnostics test failure. 675 Action: Use MAP 0210. C95 675-123 D C95 Description: Interface board non-wrap test failure. C98 Action: Use MAP 0210. C97 675-150 D 675 Description: Device configuration failure. software Action: Use MAP 0210. 227 675-151 D 675 Description: Device driver indicates a hardware failure. software Action: Use MAP 0210. 227 675-152 D 675 Description: Failure and error in determining which type of Artic960Hx Adapter. Action: Use MAP 0210. 675-153 D 675 Description: Error log analysis indicates a Artic960Hx Adapter failure. 227 Action: Use ERRPT command to check error log. C94 software 675-154 D C94 Description: Artic960Hx Adapter initialization failure. 675 Action: Use MAP 0210. C95 675-155 D 675 Description: Artic960Hx Adapter initialization failure. C94 Action: Use MAP 0210. C95 675-156 D C95 Description: Artic960Hx Adapter initialization failure. 675 Action: Use MAP 0210. C94 675-157 D C98 Description: Cable wrap test failure. Action: Use MAP 0210. C97 C95 677-201 D 677 Description: Configuration Register test failure 221 677-202 D 677 Description: Reset test failure 221 677-203 D 677 Description: Register test failure 221 677-204 D 677 Description: SRAM test failure 221 677-205 D 677 Description: Interrupt test failure 221 677-206 D 677 Description: PCI Loop Back test failure 221 677-207 D 677 Description: Internal Loop Back test failure 221 677-208 D 677 Description: External Loop Back test failure 221 677-209 D 677 Description: Hub Loop Back test failure xxx 677-301 D 677 Description: I/O Error on Read/Write Operation 221 Software 677-401 F C24 Description: Unisolated Loop Back test failure xxx Action: Run diagnostics again utilizing the wrap plug. 677 221 677-701 G 677 Description: Error log analysis indicates that an error has occurred with the 221 adapter. 677-702 G Microcode Description: Error log analysis indicates that an adapter microcode error has 677 occurred 678-098 J 678 Description: Tape drive indicates an error. 678-099 J 678 Description: Tape drive not found. B88 678-101 Description: Timeout while attempting to D 678 communicate with SCSI device. Description: The SCSI device indicates 678-102 D 678 busy. 678-103 Description: The SCSI device indicates a D 678 reservation conflict. 678-104 Description: The SCSI device indicates a D 678 check condition. 678-105 Description: An error is detected in D 678 request sense data. 678-107 Description: Sense data from the SCSI D 678 drive has unexpected data. 678-110 Description: The Reserve command failed. D 678 678-111 Description: Invalid condition from the D 678 drive after a reserve. 678-112 Description: The write protect sensor D 678 test failed. 678-113 Description: Invalid condition from drive D 678 after a request sense. 678-114 Description: Timeout while attempting to D 678 communicate with the SCSI device. Description: The Inquiry command failed. 678-120 D 678 678-130 Description: The Load command failed. D 678 media 678-134 Description: The adapter failed to D B88 configure. software 678-135 Description: The Unload command failed. D 678 media 678-140 Description: The Mode Select command D 678 failed. 678-150 Description: The Test Unit Ready command D 678 failed. media 678-160 Description: The Send Diagnostic command D 678 failed. media 678-161 Description: Invalid condition from the D 678 drive after a reserve. B88 678-163 Description: Invalid condition from the D 678 drive after a request sense. B88 678-164 Description: Timeout while attempting to D 678 communicate with the SCSI device. B88 Description: Write, Read and Compare Test 678-165 D 678 failed. B88 276 678-166 Description: Unable to configure the D 678 device. B88 software 678-167 Description: An unexpected SCSI error D 678 occurred. B88 678-168 Description: The adapter failed to D B88 configure. software 678-169 Description: The send diagnostic command D 678 failed. media 678-170 Description: The Read, Write and Compare D 678 test failed. B88 media 678-180 Description: The Load command failed. D 678 media 678-185 Description: The Unload command failed. D 678 media 678-190 Description: The Mode Select command D 678 failed. 678-200 Description: The Test Unit Ready command D 678 failed. media 678-201 Description: Error diagnosed from error G 678 log analysis. B88 678-210 Description: The device configuration D 678 failed. B88 678-211 Description: The device open failed. D 678 B88 678-220 Description: The Release command failed. D 678 678-230 Description: The Request Sense command D 678 failed. 678-240 Description: The Openx command failed. D 678 678-260 Description: The device configuration D 678 failed. 678-261 Description: The device open failed. D 678 678-300 Description: The device configuration D 678 failed. software 678-310 Description: SCSI adapter configuration D B88 failed. 678 software 678-320 Description: Error log analysis indicates G 678 a failure. media 678-411 Description: A reservation conflict to D 678 occurred. 678-423 B88 software 678-511 Description: The drive returned bad or to D 678 non-extended sense data. 678-523 B88 678-611 Description: An adapter or bus I/O error to D 678 occurred. 678-623 B88 software 678-711 Description: A device timeout error to D 678 occurred. 678-723 B88 software 679-098 Description: The disk drive indicates an J 679 error. B88 679-099 Description: The disk drive not found. J 679 B88 679-102 Description: An unrecoverable media error D 679 occurred. 679-104 Description: The motor failed to restart. D 679 679-105 Description: The drive did not become D 679 ready. 679-106 Description: The electronics card test D 679 failed. 679-108 Description: The bus test failed. D 679 679-110 Description: The media format is D 679 corrupted. 679-112 Description: The diagnostic test failed. D 679 679-114 Description: An unrecoverable hardware D 679 error. 679-116 Description: A protocol error. D Action: Check the levels of the device, adapter, diagnostic software, and application software to be sure they are all compatible. If you do not find a problem, call your support person. 679-117 Description: A write protect error D 679 occurred. 679-118 Description: A SCSI command time-out D 679 occurred. B88 679-120 Description: A SCSI busy or command D 679 error. 679-122 Description: A SCSI reservation conflict D 679 error. 679-124 Description: A SCSI check condition error D 679 occurred. 679-126 Description: A software error was caused D 679 by a hardware failure. B88 679-128 Description: The error log analysis G 679 indicates a hardware failure. 679-129 G D50 Description: Error log analysis indicates a SCSI bus problem. 679 B88 software 679-130 G 679 Description: Error log analysis indicates a problem reported by the disk drive's self monitoring function. 679-132 Description: A disk drive hardware error D 679 occurred. 679-134 Description: The adapter failed to D B88 configure. software 679-135 D 679 Description: The device failed to B88 configure. software 679-136 Description: The certify operation D 679 failed. save 679-137 D 679 Description: Unit attention condition has occurred on the Send Diagnostic command. B88 D50 681-098 J 681 Description: The disk drive indicates an error. B88 681-099 J 681 Description: The disk drive not found. B88 681-102 D 681 Description: An unrecoverable media error occurred. 681-104 D 681 Description: The motor failed to restart. 681-105 D 681 Description: The drive did not become ready. 681-106 D 681 Description: The electronics card test failed. 681-108 D 681 Description: The bus test failed. 681-110 D 681 Description: The media format is corrupted. 681-112 D 681 Description: The diagnostic test failed. 681-114 D 681 Description: An unrecoverable hardware error. 681-116 D Description: A protocol error. Action: Check the levels of the device, adapter, diagnostic software, and application software to be sure they are all compatible. If you do not find a problem, call your support person. 681-117 D 681 Description: A write protect error occurred. 681-118 D 681 Description: A SCSI command time-out occurred. B88 681-120 D 681 Description: A SCSI busy or command error. 681-122 D 681 Description: A SCSI reservation conflict error. 681-124 D 681 Description: A SCSI check condition error occurred. 681-126 D 681 Description: A software error was caused by a hardware failure. B88 681-128 G 681 Description: The error log analysis indicates a hardware failure. 681-129 G D50 Description: Error log analysis indicates a SCSI bus problem. 681 B88 software 681-130 G 681 Description: Error log analysis indicates a problem reported by the disk drive's self monitoring function. 681-132 D 681 Description: A disk drive hardware error occurred. 681-134 D B88 Description: The adapter failed to configure. software 681-135 D 681 Description: The device failed to configure. B88 software 681-136 D 681 Description: The certify operation failed. 681-137 D 681 Description: Unit attention condition has occurred on the Send Diagnostic command. B88 D50 682-098 J 682 Description: IPLROS detected a problem with the CD-ROM drive B88 221 682-099 J 682 Description: IPLROS detected a problem with the CD-ROM drive B88 682-111 D 682 Description: Unable to reserve device. B88 682-112 D 682 Description: Unable to do configuration. B88 682-113 D 682 Description: Unable to open the device driver. B88 682-121 D 682 Description: The CD-ROM drive indicates an error. 682-122 D 682 Description: The CD-ROM drive indicates an error. 682-123 D 682 Description: The CD-ROM drive indicates an error. 682-125 D 682 Description: The CD-ROM drive indicates an error. B88 682-126 D 682 Description: The CD-ROM drive indicates an error. 682-127 D 682 Description: The CD-ROM drive indicates an error. 682-128 D 682 Description: The CD-ROM drive indicates an error. 682-129 D 682 Description: The CD-ROM drive indicates an error. 682-150 D Media Description: A media error was detected. 682 682-151 D 682 Description: A command timeout was detected. D88 682-152 D 682 Description: A command reservation conflict was detected. 682-162 D 682 Description: The CD-ROM drive indicates an error. 682-171 D 682 Description: Unable to reserve device. 682-172 D 682 Description: Unable to do configuration. 682-173 D 682 Description: Unable to open device driver. 682-175 D 682 Description: The CD-ROM drive indicates an error. 682-198 D 682 Description: Undefined error detected. B88 682-199 D 682 Description: Undefined error detected. 682-211 D 682 Description: The LED test failed. 682-281 D 682 Description: No tone during audio test. 682-301 G 682 Description: Errors found during ELA. 682-302 G 682 Description: Errors found during ELA. B88 685-001 D 685 Description: RGB_SCREEN_USER_FAIL Monitor/ cable 685-040 D 685 Description: STATUS_POLL_TIMEOUT_ERROR 227 Monitor/ cable 685-041 D 685 Description: CRC_POLL_TIMEOUT_ERROR 227 Monitor/ cable 685-060 D software Description: SVC_AIDS_INPUT_ERROR 685 685-081 D software Description: LOOP_COUNT_WAS_ZERO 685 685-082 D software Description: INVALID_TU_NUMBER 685 685-0B0 D software Description: ROM test failed 685 685-0B1 D software Description: ROM test failed 685 685-0D0 D software Description: INTERNAL_ERROR_DATA_SIZE_0 685 685-0D1 D software Description: INTERNAL_ERROR_DATA_SIZE_1 685 685-0D2 D software Description: INTERNAL_ERROR_DATA_SIZE_2 685 685-0D3 D software Description: INTERNAL_ERROR_DATA_SIZE_3 685 685-0D5 D software Description: ODM INIT FAILED 685 685-0D6 D software Description: ODM_OBJECT_SEARCH_FAILED 685 685-0D8 D software Description: ODM_GET_OBJECT_FAILED 685 685-0D9 D software Description: ODM_TERM_FAILED 685 685-0DB D software Description: ILLEGAL_RESOLUTION_SPECIFIED 685 685-0E5 D software Description: AIXGSC_MGA_START_INTERRUPT_FAILED 685 685-0E6 D software Description: AIXGSC_MGA_STOP_INTERRUPT_FAILED 685 685-0E7 D software Description: MDD_OPEN_BUS_FAILED 685 685-0E8 D software Description: MDD_IOCTL_ERROR 685 685-0E9 D software Description: OPEN_RCM_ERROR 685 685-0EA D software Description: IOCTL_GSC_HANDLE_FAILED 685 685-0EB D software Description: AIXGSC_MAKE_GP_FAILED 685 685-0EC D software Description: AIXGSC_UNMAKE_GP_FAILED 685 685-0ED D software Description: DEVICE_BUSY_ERROR 685 685-0EE D software Description: AIXGSC_MGA_SET_DISPLAY_FAILED 685 685-100 D 685 Description: REG_32_BIT_PRTN_ERROR 227 Monitor/ cable 685-101 D 685 Description: REG_32_BIT_ADDR_UNIQ_ERROR 227 Monitor/ cable 685-102 D 685 Description: REG_8_BIT_PTRN_ERROR 227 Monitor/ cable 685-103 D 685 Description: REG_8_BIT_ADDR_UNIQ_ERROR 227 Monitor/ cable 685-104 D 685 Description: CRTC_REGS_PTRN_ERROR 227 Monitor/ cable 685-105 D 685 Description: CRTC_REGS_ADDR_UNIQ_ERROR 227 Monitor/ cable 685-106 D 685 Description: CRTCEXT_REGS_PTRN_ERROR 227 Monitor/ cable 685-107 D 685 Description: CRTCEXT_REGS_ADDR_UNIQ_ERROR 227 Monitor/ cable 685-108 D 685 Description: RAMDAC_REGS_PTRN_ERROR 227 Monitor/ cable 685-109 D 685 Description: RAMDAC_REGS_ADDR_UNIQ_ERROR 227 Monitor/ cable 685-10A D 685 Description: PALETTE_REGS_PTRN_ERROR 227 Monitor/ cable 685-10B D 685 Description: PALETTE_REGS_ADDR_UNIQ_ERROR 227 Monitor/ cable 685-200 D 685 Description: ROM test failed 227 685-201 D 685 Description: ROM test failed 227 685-202 D 685 Description: ROM test failed 227 685-203 D 685 Description: ROM test failed 227 685-204 D 685 Description: ROM test failed 227 685-205 D 685 Description: ROM test failed 227 685-206 D 685 Description: ROM test failed 227 685-207 D 685 Description: ROM test failed 227 685-208 D 685 Description: ROM test failed 227 685-209 D 685 Description: ROM test failed 227 685-20B D 685 Description: ROM test failed 227 685-400 D 685 Description: SGRAM_RED_SCREEN_ERROR 227 Monitor/ cable 685-401 D 685 Description: SGRAM_GREEN_SCREEN_ERROR 227 Monitor/ cable 685-402 D 685 Description: SGRAM_BLUE_SCREEN_ERROR 227 Monitor/ cable 685-403 D 685 Description: SGRAM_WHITE_SCREEN_ERROR 227 Monitor/ cable 685-404 D 685 Description: SGRAM_INCREMENTING_SCREEN_ERROR 227 Monitor/ cable 685-500 D 685 Description: BLIT_TEST_ERROR_640 x 480 227 Monitor/ cable 685-501 D 685 Description: BLIT_TEST_ERROR_800 x 600 227 Monitor/ cable 685-502 D 685 Description: BLIT_TEST_ERROR_1024 x 768 227 Monitor/ cable 685-503 D 685 Description: BLIT_TEST_ERROR_1280 x 1024 227 Monitor/ cable 685-504 D software Description: INTERNAL_ERROR_DATA_SIZE_4 685 685-600 D 685 Description: DRAW_TEST_ERROR_640 x 480_A 227 Monitor/ cable 685-601 D 685 Description: DRAW_TEST_ERROR_800 x 600_A 227 Monitor/ cable 685-602 D 685 Description: DRAW_TEST_ERROR_1024 x 768_A 227 Monitor/ cable 685-603 D 685 Description: DRAW_TEST_ERROR_1280 x 1024_A 227 Monitor/ cable 685-604 D software Description: INTERNAL_ERROR_DATA_SIZE_5 685 685-605 D 685 Description: DRAW_TEST_ERROR_640 x 480_B 227 Monitor/ cable 685-606 D 685 Description: DRAW_TEST_ERROR_800 x 600_B 227 Monitor/ cable 685-607 D 685 Description: DRAW_TEST_ERROR_1024 x 768_B 227 Monitor/ cable 685-608 D 685 Description: DRAW_TEST_ERROR_1280 x 1024_B 227 Monitor/ cable 685-609 D software Description: INTERNAL_ERROR_DATA_SIZE_6 685 685-60A D 685 Description: DRAW_TEST_ERROR_640 x 480_C 227 Monitor/ cable 685-60B D 685 Description: DRAW_TEST_ERROR_800 x 600_C 227 Monitor/ cable 685-60C D 685 Description: DRAW_TEST_ERROR_1024 x 768_C 227 Monitor/ cable 685-60D D 685 Description: DRAW_TEST_ERROR_1280 x 1024_C 227 Monitor/ cable 685-60E D software Description: INTERNAL_ERROR_DATA_SIZE_7 685 686-114 D 686 Description: The register verification test failed. 686-124 D 686 Description: The adapter RAM verification test failed. 686-152 D 686 Description: The data wrap communication test failed. Note: The cable could be defective. The cable FRU part number is listed along with the adapter under FFC 686. 686-153 D 686 Description: The modem control line test failed. 686-252 D 686 Description: The data wrap communication test failed. 686-253 D 686 Description: The modem control line test failed. 686-501 D 686 Description: Adapter Reset failed 686-511 D 686 Description: Adapter to host memory test failed (byte tag test) 686-512 D 686 Description: Adapter to host memory test failed (word tag test) 686-513 D 686 Description: Adapter to host memory test failed (byte pattern test) 686-514 D 686 Description: Adapter to host memory test failed (word pattern test) 686-521 D 686 Description: Adapter BIOS POST CPU failed 686-522 D 686 Description: Adapter BIOS POST Checksum failed 686-523 D 686 Description: Adapter BIOS POST Timer failed 686-524 D 686 Description: Adapter BIOS POST RAM failed 686-526 D 686 Description: Adapter BIOS POST Async Ports failed 686-527 D 686 Description: Adapter BIOS Misc. failed 686-528 D 686 Description: Adapter BIOS Reset failed 686-529 D 686 Description: Adapter BIOS Download failed 686-531 D 686 Description: Adapter BIOS Command failed 686-533 D 686 Description: Adapter BIOS Timer test failed 686-534 D 686 Description: Adapter BIOS RAM test failed 686-541 D 686 Description: Port async internal loopback test failed (general) 686-542 D 686 Description: Port async internal loopback test failed (no response from the port) 686-551 D 686 Description: Port async external loopback test failed (general) 686-552 D 686 Description: Port async external loopback test failed (data signals) 686-553 D 686 Description: Port async external loopback test failed (control signals) 686-554 D 686 Description: Port async external loopback test failed (modem signals) 686-555 D 686 Description: Port async external loopback test failed (no response from port) 686-901 D software Description: An unexpected error occurred that can be attributed to software or to 686 hardware. Action: Run diagnostics from a source other 686-920 than from the disk or a network. If the same error occurs or if the original SRN was not obtained from disk or a network based diagnostics, use Chapter 12. "MAP 0210: General Problem Resolution" with a FFC of 686; otherwise, suspect a software problem. 686-921 D 686 Description: The adapter failed to configure. software 686-922 D software Description: An unexpected error occurred that can be attributed to software or to 686 hardware. Action: Run diagnostics from a source other 686-924 than from the disk or a network. If the same error occurs or if the original SRN was not obtained from disk or a network based diagnostics, use Chapter 12. "MAP 0210: General Problem Resolution" with a FFC of 686; otherwise, suspect a software problem. 686-925 D 686 Description: The adapter failed to configure. software 686-926 D software Description: An unexpected error occurred that can be attributed to software or to 686 hardware. Action: Run diagnostics from a source other 686-950 than from the disk or a network. If the same error occurs or if the original SRN was not obtained from disk or a network based diagnostics, use Chapter 12. "MAP 0210: General Problem Resolution" with a FFC of 686; otherwise, suspect a software problem. 687-114 D 687 Description: The register verification test failed. 687-124 D 687 Description: The adapter RAM verification test failed. 687-152 D 687 Description: The data wrap communication test failed. 837 684 152 687-153 D 687 Description: The modem control line test failed. 687-252 D 687 Description: The data wrap communication test failed. 687-253 D 687 Description: The modem control line test failed. 687-144 D 687 Description: The sync line test failed. 687-244 D 687 Description: The sync line test failed. 687-501 D 687 Description: Adapter Reset failed 687-502 D 687 Description: Adapter Fuse failed 687-511 D 687 Description: Adapter to host memory test failed (byte tag test) 687-512 D 687 Description: Adapter to host memory test failed (word tag test) 687-513 D 687 Description: Adapter to host memory test failed (byte pattern test) 687-514 D 687 Description: Adapter to host memory test failed (word pattern test) 687-521 D 687 Description: Adapter BIOS POST CPU failed 687-522 D 687 Description: Adapter BIOS POST Checksum failed 687-523 D 687 Description: Adapter BIOS POST Timer failed 687-524 D 687 Description: Adapter BIOS POST RAM failed 687-525 D 687 Description: Adapter BIOS POST Sync Line failed 687-527 D 687 Description: Adapter BIOS Misc. failed 687-528 D 687 Description: Adapter BIOS Reset failed 687-529 D 687 Description: Adapter BIOS Download failed 687-531 D 687 Description: Adapter BIOS Command failed 687-533 D 687 Description: Adapter BIOS Timer test failed 687-534 D 687 Description: Adapter BIOS RAM test failed 687-541 D 687 Description: Port sync internal loopback test failed 687-551 D 687 Description: Port sync external loopback test failed 687-600 D 837 Description: 232RAN status test failed 687-700 D 684 Description: 422RAN status test failed 687-901 D software Description: An unexpected error occurred that can be attributed to software or to 687 hardware. Action: Run diagnostics from a source other 687-920 than from the disk or a network. If the same error occurs or if the original SRN was not obtained from disk or a network based diagnostics, use Chapter 12. "MAP 0210: General Problem Resolution" with a FFC of 687; otherwise, suspect a software problem. 687-921 D software Description: The adapter failed to configure. 687 687-922 D software Description: An unexpected error occurred to that can be attributed to software or 687-924 687 hardware. Action: Run diagnostics from a source other than from the disk or a network. If the same error occurs or if the original SRN was not obtained from disk or a network based diagnostics, use Chapter 12. "MAP 0210: General Problem Resolution" with a FFC of 687; otherwise, suspect a software problem. 687-925 D 687 Description: The adapter failed to configure. software 687-926 D software Description: An unexpected error occurred that can be attributed to software or to 687 hardware. Action: Run diagnostics from a source other 687-950 than from the disk or a network. If the same error occurs or if the original SRN was not obtained from disk or a network based diagnostics, use Chapter 12. "MAP 0210: General Problem Resolution" with a FFC of 687; otherwise, suspect a software problem. 689-098 Description: The disk drive indicates an J 689 error. B88 689-099 Description: The disk drive not found. J 689 B88 689-102 Description: An unrecoverable media error D 689 occurred. 689-104 Description: The motor failed to restart. D 689 689-105 Description: The drive did not become D 689 ready. 689-106 Description: The electronics card test D 689 failed. 689-108 Description: The bus test failed. D 689 689-110 Description: The media format is D 689 corrupted. 689-112 Description: The diagnostic test failed. D 689 689-114 Description: An unrecoverable hardware D 689 error. 689-116 Description: A protocol error. D Action: Check the levels of the device, adapter, diagnostic software, and application software to be sure they are all compatible. If you do not find a problem, call your support person. 689-117 Description: A write protect error D 689 occurred. 689-118 Description: A SCSI command time-out D 689 occurred. B88 689-120 Description: A SCSI busy or command D 689 error. 689-122 Description: A SCSI reservation conflict D 689 error. 689-124 Description: A SCSI check condition error D 689 occurred. 689-126 Description: A software error was caused D 689 by a hardware failure. B88 689-128 Description: The error log analysis G 689 indicates a hardware failure. 689-129 G D50 Description: Error log analysis indicates a SCSI bus problem. 689 B88 software 689-130 G 689 Description: Error log analysis indicates a problem reported by the disk drive's self monitoring function. 689-132 Description: A disk drive hardware error D 689 occurred. 689-134 Description: The adapter failed to D B88 configure. software 689-135 D 689 Description: The device failed to B88 configure. software 689-136 Description: The certify operation D 689 failed. save 689-137 D 689 Description: Unit attention condition has occurred on the Send Diagnostic command. B88 D50 690-098 Description: The disk drive indicates an J 690 error. B88 690-099 Description: The disk drive not found. J 690 B88 690-102 Description: An unrecoverable media error D 690 occurred. 690-104 Description: The motor failed to restart. D 690 690-105 Description: The drive did not become D 690 ready. 690-106 Description: The electronics card test D 690 failed. 690-108 Description: The bus test failed. D 690 690-110 Description: The media format is D 690 corrupted. 690-112 Description: The diagnostic test failed. D 690 690-114 Description: An unrecoverable hardware D 690 error. 690-116 Description: A protocol error. D Action: Check the levels of the device, adapter, diagnostic software, and application software to be sure they are all compatible. If you do not find a problem, call your support person. 690-117 Description: A write protect error D 690 occurred. 690-118 Description: A SCSI command time-out D 690 occurred. B88 690-120 Description: A SCSI busy or command D 690 error. 690-122 Description: A SCSI reservation conflict D 690 error. 690-124 Description: A SCSI check condition error D 690 occurred. 690-126 Description: A software error was caused D 690 by a hardware failure. B88 690-128 Description: The error log analysis G 690 indicates a hardware failure. 690-129 G D50 Description: Error log analysis indicates a SCSI bus problem. 690 B88 software 690-130 G 690 Description: Error log analysis indicates a problem reported by the disk drive's self monitoring function. 690-132 Description: A disk drive hardware error D 690 occurred. 690-134 Description: The adapter failed to D B88 configure. software 690-135 D 690 Description: The device failed to B88 configure. software 690-136 D 690 Description: The certify operation failed. 690-137 D 690 Description: Unit attention condition has occurred on the Send Diagnostic command. B88 D50 691-200 D 691 Description: The ATM 25Mbps Adapter open test failed. 227 691-202 D 691 Description: The ATM 25Mbps Adapter register test failed. 227 691-203 D 691 Description: The ATM 25Mbps Adapter memory test failed. 227 691-204 D 691 Description: The ATM 25Mbps Adapter NVRAM test failed. 227 691-205 D 691 Description: The ATM 25Mbps Adapter interrupt test failed. 227 691-206 D 691 Description: The ATM 25Mbps Adapter wrap test failed. 227 691-210 D 691 Description: The ATM 25Mbps Adapter close test failed. 227 691-220 D 691 Description: The ATM 25Mbps Adapter was not found. 227 Action: Re-install the ATM 25Mbps Adapter and re-run the test. If the error continues, use Chapter 12. "MAP 0210: General Problem Resolution". 691-300 D Wrap Plug Description: The ATM 25Mbps Adapter wrap test failed. 691 Action: Re-install the wrap plug and re-run the test. If the error continues, use 227 Chapter 12. "MAP 0210: General Problem Resolution". 691-700 G 691 Description: Error log analysis reported a hardware error. 227 692-110 D 692 Description: The Reserve command failed. 692-120 D 692 Description: The Inquiry command failed. 692-130 D 692 Description: The Load command failed. media 692-135 D 692 Description: The Unload command failed. media 692-140 D 692 Description: The Mode Select command failed. 692-150 D 692 Description: The Test Unit Ready command failed. media 692-160 D 692 Description: The Send Diagnostic command failed. media 692-169 D 692 Description: The send diagnostic command failed. media 692-170 D 692 Description: The Read, Write and Compare test failed. B88 media 692-180 D 692 Description: The Load command failed. media 692-185 D 692 Description: The Unload command failed. media 692-190 D 692 Description: The Mode Select command failed. 692-200 D 692 Description: The Test Unit Ready command failed. media 692-210 D 692 Description: The device configuration failed. B88 692-220 D 692 Description: The Release command failed. 692-230 D 692 Description: The Request Sense command failed. 692-240 D 692 Description: The Openx command failed. 692-300 D 692 Description: The device configuration failed. software 692-310 D B88 Description: SCSI adapter configuration failed. 692 software 692-320 G 692 Description: Error log analysis indicates a failure. media 692-411 D 692 Description: A reservation conflict to occurred. 692-423 B88 software 692-511 D 692 Description: The drive returned bad or to non-extended sense data. 692-523 B88 692-611 D 692 Description: An adapter or bus I/O error to occurred. 692-623 B88 software 692-711 D 692 Description: A device timeout error to occurred. 692-723 B88 software 693-100 D 693 Description: Adapter open failed. 227 693-101 D 693 Description: Adapter config register test failed. 227 693-102 D 693 Description: Adapter reset failed. 227 693-103 D 693 Description: Adapter I/O register test failed. 227 693-104 D 693 Description: Adapter microcode download test failed. 227 693-105 D 693 Description: Adapter internal wrap test failed. 227 693-106 D 693 Description: Adapter close failed. 227 697-100 D 697 Description: Charm memory write failure software 227 697-101 D 697 Description: Charm memory read failure software 227 697-102 D 697 Description: PCI configuration register write failure software 227 697-103 D 697 Description: Charm software reset failure software 227 697-104 D 697 Description: Packet memory error software 227 697-105 D 697 Description: Control memory failure software 227 697-106 D 697 Description: Link-R detected bad parity 697-107 D 697 Description: Suni detected bad parity 697-108 D 697 Description: Suni initialization failure 697-109 D Wrap Plug Description: Loss of light detected in Link test 697 Action: Check wrap plug installation. 697-10B D Wrap Plug Description: External Loopback failed Action: Check wrap plug installation. 697 697-10C D 697 Description: Internal Loopback failed software 227 697-10D D 697 Description: DMS failed 227 software 697-1FF D 697 Description: EPROM checksum failed software 227 697-200 D software Description: Klog error 697 227 697-201 D software Description: ASL error 697 227 697-202 D software Description: ODM Initialization error 697 227 697-203 D software Description: Diagnostic configuration failure 697 227 697-205 D software Description: Error in diag open 697 227 697-206 D software Description: Error in releasing adapter 697 227 698-100 D 698 Description: Charm memory write failure software 227 698-101 D 698 Description: Charm memory read failure software 227 698-102 D 698 Description: PCI configuration register write failure software 227 698-103 D 698 Description: Charm software reset failure software 227 698-104 D 698 Description: Packet memory error software 227 698-105 D 698 Description: Control memory failure software 227 698-106 D 698 Description: Link-R detected bad parity 698-107 D 698 Description: Suni detected bad parity 698-108 D 698 Description: Suni initialization failure 698-109 D Wrap Plug Description: Loss of light detected in Link test 698 Action: Check wrap plug installation. 698-10B D Wrap Plug Description: External Loopback failed Action: Check wrap plug installation. 698 698-10C D 698 Description: Internal Loopback failed software 227 698-10D D 698 Description: DMS failed 227 software 698-1FF D 698 Description: EPROM checksum failed software 227 698-200 D software Description: Klog error 698 227 698-201 D software Description: ASL error 698 227 698-202 D software Description: ODM Initialization error 698 227 698-203 D software Description: Diagnostic configuration failure 698 227 698-205 D software Description: Error in diag open 698 227 698-206 D software Description: Error in releasing adapter 698 227 699-100 D 699 Description: An error was found on the adapter 699-110 G 699 Description: Error Log analysis indicates a hardware error. 699-120 D 699 Description: Adapter hardware has caused a software failure. 700-102 D 700 Description: 1.1GB single-ended disk drive to problem. 700-114 700-116 D Description: A protocol error. Action: Check the levels of the device, adapter, diagnostic software, and application software to be sure they are all compatible. If you do not find a problem, call your support person. 700-117 D 700 Description: A write protect error occurred. 700-118 D 700 Description: A SCSI command time-out. B88 700-120 D 700 Description: A SCSI error. to 700-124 700-126 D 700 Description: A software error was caused by a hardware failure. B88 700-128 G 700 Description: The error log analysis indicates a hardware failure. 700-129 G D50 Description: Error log analysis indicates a SCSI bus problem. 700 B88 software 700-130 G 700 Description: Error log analysis indicates a problem reported by the disk drive's self monitoring function. 700-132 D 700 Description: A disk drive hardware error occurred. 700-134 D B88 Description: The adapter failed to configure. software 700-135 D 700 Description: The device failed to configure. B88 software 700-136 D 700 Description: The certify operation failed. 700-137 D 700 Description: Unit attention condition has occurred on the Send Diagnostic command. B88 D50 701-102 D 701 Description: 1.1GB 16-bit single-ended to disk drive problem. 701-114 701-116 D Description: A protocol error. Action: Check the levels of the device, adapter, diagnostic software, and application software to be sure they are all compatible. If you do not find a problem, call your support person. 701-117 D 701 Description: A write protect error occurred. 701-118 D 701 Description: A SCSI command time-out. B88 701-120 D 701 Description: A SCSI error. to 701-124 701-126 D 701 Description: A software error was caused by a hardware failure. B88 701-128 G 701 Description: The error log analysis indicates a hardware failure. 701-129 G D50 Description: Error log analysis indicates a SCSI bus problem. 701 B88 software 701-130 G 701 Description: Error log analysis indicates a problem reported by the disk drive's self monitoring function. 701-132 D 701 Description: A disk drive hardware error occurred. 701-134 D B88 Description: The adapter failed to configure. software 701-135 D 701 Description: The device failed to configure. B88 software 701-136 D 701 Description: The certify operation failed. 701-137 D 701 Description: Unit attention condition has occurred on the Send Diagnostic command. B88 D50 702-102 D 702 Description: 1.1GB 16-bit differential to disk drive problem. 702-114 702-116 D Description: A protocol error. Action: Check the levels of the device, adapter, diagnostic software, and application software to be sure they are all compatible. If you do not find a problem, call your support person. 702-117 D 702 Description: A write protect error occurred. 702-118 D 702 Description: A SCSI command time-out. B88 702-120 D 702 Description: A SCSI error. to 702-124 702-126 D 702 Description: A software error was caused by a hardware failure. B88 702-128 G 702 Description: The error log analysis indicates a hardware failure. 702-129 G D50 Description: Error log analysis indicates a SCSI bus problem. 702 B88 software 702-130 G 702 Description: Error log analysis indicates a problem reported by the disk drive's self monitoring function. 702-132 D 702 Description: A disk drive hardware error occurred. 702-134 D B88 Description: The adapter failed to configure. software 702-135 D 702 Description: The device failed to configure. B88 software 702-136 D 702 Description: The certify operation failed. 702-137 D 702 Description: Unit attention condition has occurred on the Send Diagnostic command. B88 D50 703-102 D 703 Description: 2.2GB single-ended disk drive to problem. 703-114 703-116 D Description: A protocol error. Action: Check the levels of the device, adapter, diagnostic software, and application software to be sure they are all compatible. If you do not find a problem, call your support person. 703-117 D 703 Description: A write protect error occurred. 703-118 D 703 Description: A SCSI command time-out. B88 703-120 D 703 Description: A SCSI error. to 703-124 703-126 D 703 Description: A software error was caused by a hardware failure. B88 703-128 G 703 Description: The error log analysis indicates a hardware failure. 703-129 G D50 Description: Error log analysis indicates a SCSI bus problem. 703 B88 software 703-130 G 703 Description: Error log analysis indicates a problem reported by the disk drive's self monitoring function. 703-132 D 703 Description: A disk drive hardware error occurred. 703-134 D B88 Description: The adapter failed to configure. software 703-135 D 703 Description: The device failed to configure. B88 software 703-136 D 703 Description: The certify operation failed. 703-137 D 703 Description: Unit attention condition has occurred on the Send Diagnostic command. B88 D50 704-102 D 704 Description: 2.2GB 16-bit single-ended to disk drive problem. 704-114 704-116 D Description: A protocol error. Action: Check the levels of the device, adapter, diagnostic software, and application software to be sure they are all compatible. If you do not find a problem, call your support person. 704-117 D 704 Description: A write protect error occurred. 704-118 D 704 Description: A SCSI command time-out. B88 704-120 D 704 Description: A SCSI error. to 704-124 704-126 D 704 Description: A software error was caused by a hardware failure. B88 704-128 G 704 Description: The error log analysis indicates a hardware failure. 704-129 G D50 Description: Error log analysis indicates a SCSI bus problem. 704 B88 software 704-130 G 704 Description: Error log analysis indicates a problem reported by the disk drive's self monitoring function. 704-132 D 704 Description: A disk drive hardware error occurred. 704-134 D B88 Description: The adapter failed to configure. software 704-135 D 704 Description: The device failed to configure. B88 software 704-136 D 704 Description: The certify operation failed. 704-137 D 704 Description: Unit attention condition has occurred on the Send Diagnostic command. B88 D50 705-102 D 705 Description: 2.2GB 16-bit differential to disk drive problem. 705-114 705-116 D Description: A protocol error. Action: Check the levels of the device, adapter, diagnostic software, and application software to be sure they are all compatible. If you do not find a problem, call your support person. 705-117 D 705 Description: A write protect error occurred. 705-118 D 705 Description: A SCSI command time-out. B88 705-120 D 705 Description: A SCSI error. to 705-124 705-126 D 705 Description: A software error was caused by a hardware failure. B88 705-128 G 705 Description: The error log analysis indicates a hardware failure. 705-129 G D50 Description: Error log analysis indicates a SCSI bus problem. 705 B88 software 705-130 G 705 Description: Error log analysis indicates a problem reported by the disk drive's self monitoring function. 705-132 D 705 Description: A disk drive hardware error occurred. 705-134 D B88 Description: The adapter failed to configure. software 705-135 D 705 Description: The device failed to configure. B88 software 705-136 D 705 Description: The certify operation failed. 705-137 D 705 Description: Unit attention condition has occurred on the Send Diagnostic command. B88 D50 706-102 D 706 Description: 4.5GB 16-bit single-ended to disk drive problem 706-114 706-116 D Description: A protocol error. Action: Check the levels of the device, adapter, diagnostic software, and application software to be sure they are all compatible. If you do not find a problem, call your support person. 706-117 D 706 Description: A write protect error occurred. 706-118 D 706 Description: A SCSI command time-out. B88 706-120 D 706 Description: A SCSI error. to 706-124 706-126 D 706 Description: A software error was caused by a hardware failure. B88 706-128 G 706 Description: The error log analysis indicates a hardware failure. 706-129 G D50 Description: Error log analysis indicates a SCSI bus problem. 706 B88 software 706-130 G 706 Description: Error log analysis indicates a problem reported by the disk drive's self monitoring function. 706-132 D 706 Description: A disk drive hardware error occurred. 706-134 D B88 Description: The adapter failed to configure. software 706-135 D 706 Description: The device failed to configure. B88 software 706-136 D 706 Description: The certify operation failed. 706-137 D 706 Description: Unit attention condition has occurred on the Send Diagnostic command. B88 D50 707-102 D 707 Description: Any of the following may have to occurred: an unrecoverable media error, 707-114 motor failed to restart, the drive did not become ready, electronics card test failed, bus test failed, media format failed, or diagnostic test failed. 707-116 D Description: A protocol error. Action: Check the levels of the device, adapter, diagnostic software, and application software to be sure they are all compatible. If you do not find a problem, call your support person. 707-117 D 707 Description: A write protect error occurred. 707-118 D 707 Description: A SCSI command time-out. B88 707-120 D 707 Description: A SCSI error. to 707-124 707-126 D 707 Description: A software error was caused by a hardware failure. B88 707-128 G 707 Description: The error log analysis indicates a hardware failure. 707-129 G D50 Description: Error log analysis indicates a SCSI bus problem. 707 B88 software 707-130 G 707 Description: Error log analysis indicates a problem reported by the disk drive's self monitoring function. 707-132 D 707 Description: A disk drive hardware error occurred. 707-134 D B88 Description: The adapter failed to configure. software 707-135 D 707 Description: The device failed to configure. B88 software 707-136 D 707 Description: The certify operation failed. 707-137 D 707 Description: Unit attention condition has occurred on the Send Diagnostic command. B88 D50 709-101 D 709 Description: Cannot run the test because the device driver detected a hardware error. 709-111 D 709 Description: Could not do the test because the device driver detected a hardware 221 error. 709-112 D 709 Description: Unable to determine the type of adapter from the VPD. 221 709-113 D 709 Description: The VPD verification test failed. 709-114 D 709 Description: The register verification test failed. 709-115 D 709 Description: The VPD verification test failed. 709-116 D D57 Description: The 128-port controller line test failed. 709 709-117 D 684 Diagnostics: Remote Async Node test failed. 709-118 D 837 Description: Remote async node test failed. 709-119 F 709 Description: Sync line termination test failed. 709-151 D 837 Description: Could not perform because the device driver detected a hardware error. 709-152 D 837 Description: The data wrap communication test failed. 836 709-153 D 837 Description: The modem control line test failed. 709-154 D 684 Diagnostics: Cannot run the test because the 709 device driver detected a hardware error. 709-155 D 684 Diagnostics: The data wrap communications test failed. 709 152 709-161 D 266 Description: Could not perform because the device driver detected a hardware error. 709-162 D 266 Description: The data wrap communication test failed. 709-163 D 266 Description: The modem control line test failed. 709-164 D D06 Description: The data wrap communication test failed. 709-171 D 259 Description: Could not perform because the device driver detected a hardware error. 709-172 D 259 Description: The data wrap communication test failed. 709-173 D 259 Description: The modem control line test failed. 709-174 D 263 Description: Cannot run the test because the device driver detected a hardware error. 709-175 D 263 Description: The data wrap communications test failed. 709-181 D 261 Description: Could not perform because the device driver detected a hardware error. 709-182 D 261 Description: The data wrap communication test failed. 709-183 D 261 Description: The modem control line test failed. 709-251 D 709 Description: Could not perform because the device driver detected a hardware error. 837 709-252 D 709 Description: The data wrap communication test failed. 837 709-253 D 709 Description: The modem control line test failed. 837 709-254 D 709 Diagnostics: Cannot run the test because the device 684 driver detected a hardware error while running the Remote Async Node wrap test. 709-255 D 709 Diagnostics: The data wrap communications test failed while running the Remote Async 684 Node wrap test. 709-271 D 709 Description: Could not perform because the device driver detected a hardware error. 837 709-272 D 709 Description: The data wrap communication test failed. 837 709-273 D 709 Description: The modem control line test failed. 837 709-274 D 709 Diagnostics: Cannot run the test because the device 684 driver detected a hardware error while running the Printer/Terminal cable wrap test. 709-275 D 709 Diagnostics: The data wrap communications test failed while running the 684 Printer/Terminal cable wrap test. 709-281 D 709 Description: Could not perform because the device driver detected a hardware error. 837 709-282 D 709 Description: The data wrap communication test failed. 837 709-283 D 709 Description: The modem control line test failed. 837 709-481 D D56 Description: Could not do the test because the device driver detected a hardware error. 709-482 D D56 Description: The data wrap communication test failed. 709-483 D D56 Description: The modem control line test failed. 709-901 D software Description: An unexpected error occurred that can be attributed to software or to 709 hardware. 709-920 Action: Run diagnostics from a source other than from the disk or a network. If the same error occurs or if the original SRN was not obtained from disk or a network based diagnostics, use Chapter 12. "MAP 0210: General Problem Resolution" with a FFC of 709; otherwise, suspect a software problem. 709-921 D 709 Description: The adapter failed to configure software 709-922 D software Description: An unexpected error occurred that can be attributed to software or to 709 hardware. 709-924 Action: Run diagnostics from a source other than from the disk or a network. If the same error occurs or if the original SRN was not obtained from disk or a network based diagnostics, use Chapter 12. "MAP 0210: General Problem Resolution" with a FFC of 709; otherwise, suspect a software problem. 709-925 D 709 Description: The adapter failed to configure software 709-926 D software Description: An unexpected error occurred that can be attributed to software or to 709 hardware. 709-943 Action: Run diagnostics from a source other than from the disk or a network. If the same error occurs or if the original SRN was not obtained from disk or a network based diagnostics, use Chapter 12. "MAP 0210: General Problem Resolution" with a FFC of 709; otherwise, suspect a software problem. 721-102 D 721 Description: Unknown SCSI or device error. to 721-114 721-116 D Description: A protocol error. Action: Check the levels of the device, adapter, diagnostic software, and application software to be sure they are all compatible. If you do not find a problem, call your support person. 721-117 D 721 Description: A write protect error occurred. 721-118 D 721 Description: A SCSI command time-out. B88 721-120 D 721 Description: Unknown SCSI or device error. to 721-124 721-126 D 721 Description: A software error was caused by a hardware failure. B88 721-128 G 721 Description: The error log analysis indicates a hardware failure. 721-130 G 721 Description: The error log analysis indicates a hardware failure. B88 721-132 D 721 Description: A disk drive hardware error occurred. 721-135 D 721 Description: The device failed to configure. B88 software 722-xxx D 722 Description: Unknown disk drive type is failing. 723-xxx D 723 Description: Unknown CD-ROM type is failing. 724-xxx D 724 Description: Unknown tape drive failure. 733-110 D 733 Description: The Reserve command failed, or the Inquiry command failed. to 733-120 733-130 D 733 Description: The Load command failed, or the Unload command failed. to media 733-135 733-140 D 733 Description: The Mode Select command failed. 733-150 D 733 Description: The Test Unit Ready command to failed, or the Send Diagnostic command 733-169 media failed. 733-170 D 733 Description: The Read, Write and Compare test failed. B88 media 733-180 D 733 Description: The Load command failed, or the Unload command failed. to media 733-185 733-190 D 733 Description: The Mode Select command failed. 733-200 D 733 Description: The Test Unit Ready command media failed. 733-210 D 733 Description: The device configuration failed. B88 733-220 D 733 Description: 140GB 8mm tape drive failed. to 733-240 733-300 D 733 Description: The device configuration failed. software 733-310 D B88 Description: SCSI adapter configuration 733 failed. software 733-320 G 733 Description: Error log analysis indicates a failure. media 733-411 D 733 Description: A reservation conflict to occurred. 733-423 B88 software 733-511 D 733 Description: The drive returned bad or to non-extended sense data. 733-523 B88 733-611 D 733 Description: An adapter, device, or bus to I/O error occurred. 733-723 B88 software 734-111 D 734 Description: Unable to reserve device. B88 734-112 D 734 Description: Unable to do configuration. B88 734-113 D 734 Description: Unable to open the device driver. B88 734-121 D 734 Description: The CD-ROM drive indicates an error. 734-122 D 734 Description: The CD-ROM drive indicates an error. 734-123 D 734 Description: The CD-ROM drive indicates an error. 734-125 D 734 Description: The CD-ROM drive indicates an error. B88 734-126 D 734 Description: The CD-ROM drive indicates an error. 734-127 D 734 Description: The CD-ROM drive indicates an error. 734-128 D 734 Description: The CD-ROM drive indicates an error. 734-129 D 734 Description: The CD-ROM drive indicates an error. 734-150 D Media Description: A media error was detected. 734 734-151 D 734 Description: A command timeout was detected. D88 734-152 D 734 Description: A command reservation conflict was detected. 734-162 D 734 Description: The CD-ROM drive indicates an error. 734-171 D 734 Description: Unable to reserve device. 734-172 D 734 Description: Unable to do configuration. 734-173 D 734 Description: Unable to open device driver. 734-175 D 734 Description: The CD-ROM drive indicates an error. 734-198 D 734 Description: Undefined error detected. B88 734-199 D 734 Description: Undefined error detected. 734-211 D 734 Description: The LED test failed. 734-281 D 734 Description: No tone during audio test. 734-301 G 734 Description: Errors found during ELA. 734-302 G 734 Description: Errors found during ELA. B88 736-101 D 821 Description: An unexpected adapter error occurred. 736-102 D 736 Description: An unexpected device or adapter error occurred. 821 736-103 D 736 Description: The keyboard reset failed. 821 736-104 D 736 Description: Unknown keyboard. 736-105 D 736 Description: The keyboard light on test failed. 821 736-106 D 736 Description: The keyboard light off test failed. 821 736-201 D 821 Description: An unexpected adapter error occurred. 736-202 D 736 Description: An unexpected device or adapter error occurred. 821 736-203 D 736 Description: The read keyboard ID test failed. 821 736-204 D 736 Description: The keyboard layout ID test failed. 736-205 D 736 Description: The keyboard echo test failed. 821 736-206 D 736 Description: The select scan code set test failed. 821 736-301 D 821 Description: An unexpected adapter error occurred. 736-302 D 736 Description: An unexpected device or adapter error occurred. 736-303 D 736 Description: An error occurred in turning on the lamps. 736-304 D 736 Description: An error occurred in turning off the lamps. 736-401 D 821 Description: An unexpected adapter error occurred. 736-402 D 736 Description: An unexpected device or adapter error occurred. 821 736-403 D 736 Description: Unable to recognize the keyboard. 736-404 D 736 Description: The keyboard is failing. 821 736-701 D 736 Description: Error configuring the device. 821 736-901 G 821 Description: The error log analysis indicates an adapter failure. 736-902 G 736 Description: The error log analysis indicates a device failure. 821 736-903 G 736 Description: The error log analysis indicates an unknown failure. 821 741-102 D 741 Description: SCSI disk drive problems. to 741-114 741-116 D Description: A protocol error. Action: Check the levels of the device, adapter, diagnostic software, and application software to be sure they are all compatible. If you do not find a problem, call your support person. 741-117 D 741 Description: A write protect error occurred. 741-118 D 741 Description: A SCSI command timeout. B88 741-120 D 741 Description: SCSI disk drive problems. to 741-124 741-126 D 741 Description: A software error was caused by a hardware failure. B88 741-128 G 741 Description: The error log analysis indicates a hardware failure. 741-129 G D50 Description: Error log analysis indicates a SCSI bus problem. 741 B88 software 741-130 G 741 Description: Error log analysis indicates a problem reported by the disk drive's self monitoring function. 741-132 D 741 Description: A disk drive hardware error occurred. 741-134 D B88 Description: The adapter failed to configure. software 741-135 D 741 Description: The device failed to configure. B88 software 741-137 D 741 Description: Unit attention condition has occurred on the Send Diagnostic command. B88 D50 742-101 D 742 Description: Configuration register test failed 742-102 D 742 Description: I/O register test failed 742-104 D 742 Description: Internal loopback test failed 742-105 D 742 Description: Internal loopback test failed 742-106 D 742 Description: External loopback test failed 742-121 D D59 Description: Configuration register test failed 742-122 D D59 Description: I/O register test failed 742-124 D D59 Description: Internal loopback test failed 742-125 D D59 Description: Internal loopback test failed 742-126 D D59 Description: External loopback test failed 742-141 D D60 Description: Configuration register test failed 742-142 D D60 Description: I/O register test failed 742-144 D D60 Description: Internal loopback test failed 742-145 D D60 Description: Internal loopback test failed 742-160 D B08 Description: 10Base-T transceiver test failed 742-161 D B09 Description: 10Base-2 transceiver test failed 742-203 D 742 Description: Device configuration failed software 742-223 D D59 Description: Device configuration failed software 742-224 D B08 Description: 10 Base-T transceiver test failed D59 742-225 D B09 Description: 10 Base-2 transceiver test failed D59 742-243 D D60 Description: Device configuration failed software 742-700 G 742 Description: Error log analysis indicates a hardware problem software 742-720 G D59 Description: Error log analysis indicates a hardware problem software 742-740 G D60 Description: Error log analysis indicates a hardware problem software 745-100 D media Description: Recovered error. Action: No action required. 745 745-200 D media Description: Drive Not Ready. Action: Install media, refer to the tape 745 autoloader service guide. 745-300 D media Description: 4mm Tape Auto Loader problem. to 745-350 745 Action: Replace media, clean drive, refer to the tape autoloader service guide. 745-400 D 745 Description: General Hardware Failure. Action: Replace media, clean drive, refer magazine to the tape autoloader service guide. media 745-410 D 745 Description: Internal Hardware Failure to Action: Replace drive, refer to the tape 745-435 media autoloader service guide. 745-440 D 745 Description: SCSI Hardware Failure. Action: Replace drive, refer to the tape SCSI autoloader service guide. Adapter 745-441 D 745 Description: 4mm Tape Auto Loader problem. to 745-443 media Action: Replace drive, refer to the tape autoloader service guide. 745-444 D 745 Description: Humidity too High Action: Lower humidity, replace media, environ- refer to the tape autoloader service guide. ment media 745-445 D clean Description: Drive Requires Cleaning Action: Clean drive, replace media, refer media to the tape autoloader service guide. drive 745-460 D 745 Description: Magazine Movement Failure to Action: Check magazine and media, clean 745-465 magazine rollers, refer to the tape autoloader service guide. media 745-470 D 745 Description: Media Insert/Eject Failure to Action: Check clean magazine and media, 745-475 magazine clean rollers, refer to the tape autoloader service guide. media 745-480 D 745 Description: Drawer Open/Close Failure to Action: Check magazine and media, refer to 745-485 magazine the tape autoloader service guide. media 745-500 D 745 Description: Illegal request to drive Action: Software conflict, refer to the system tape autoloader service guide. 745-600 D 745 Description: Unit Attention Action: Software conflict, media changed, system refer to the tape autoloader service guide. 745-700 D 745 Description: Not Writeable Action: Check media for write protect, media refer to the tape autoloader service guide. 745-800 D 745 Description: Blank Media Action: Check media, refer to the tape media autoloader service guide. 745-B00 D 745 Description: SCSI Interface Failure Action: Check SCSI interface, refer to the SCSI tape autoloader service guide. Adapter 745-D00 D 745 Description: Tape Full Action: Check replace media, refer to the media tape autoloader service guide. 746-212 D 746 Description: FIFO empty bit set. Action: Go to Chapter 7. "MAP 0050: SCSI 221 Problems Isolation Procedure". 746-213 D 746 Description: FIFO empty bit clear. Action: Go to Chapter 7. "MAP 0050: SCSI 221 Problems Isolation Procedure". 746-214 D 746 Description: FIFO full bit set. Action: Go to Chapter 7. "MAP 0050: SCSI 221 Problems Isolation Procedure". 746-215 D 746 Description: FIFO full bit clear. Action: Go to Chapter 7. "MAP 0050: SCSI 221 Problems Isolation Procedure". 746-216 D 746 Description: FIFO data miscompare. Action: Go to Chapter 7. "MAP 0050: SCSI 221 Problems Isolation Procedure". 746-217 D 746 Description: SCSI FIFO data miscompare. Action: Go to Chapter 7. "MAP 0050: SCSI 221 Problems Isolation Procedure". 746-218 D 746 Description: SCSI FIFO underflow. Action: Go to Chapter 7. "MAP 0050: SCSI 221 Problems Isolation Procedure". 746-219 D 746 Description: SCSI parity error. Action: Go to Chapter 7. "MAP 0050: SCSI 221 Problems Isolation Procedure". 746-220 D 746 Description: SCSI FIFO flags error. Action: Go to Chapter 7. "MAP 0050: SCSI 221 Problems Isolation Procedure". 746-221 D 746 Description: Miscompare during the write/read of the configuration register. 221 Action: Go to Chapter 7. "MAP 0050: SCSI Problems Isolation Procedure". 746-222 D 746 Description: Error during the write/read of the memory register. 221 Action: Go to Chapter 7. "MAP 0050: SCSI Problems Isolation Procedure". 746-223 D 746 Description: Miscompare during the write/read of the memory I/O register. 221 Action: Go to Chapter 7. "MAP 0050: SCSI Problems Isolation Procedure". 746-224 D 746 Description: Error reading the PCI configuration register. 221 746-225 D 746 Description: Adapter POST failed. 221 746-230 D D50 Description: Arbitration test failed. Action: Go to Chapter 7. "MAP 0050: SCSI 746 Problems Isolation Procedure". 746-231 D D50 Description: Function could not complete. Action: Go to Chapter 7. "MAP 0050: SCSI 746 Problems Isolation Procedure". 746-232 D D50 Description: SCSI bus data miscompare. Action: Go to Chapter 7. "MAP 0050: SCSI 746 Problems Isolation Procedure". 746-240 D 746 Description: No terminal power. Action: Go to Chapter 7. "MAP 0050: SCSI 221 Problems Isolation Procedure". 746-301 D 746 Description: Configuration open failed for parent bus. D50 software 746-700 G 746 Description: Error log analysis indicates a PCI SCSI adapter failure. software 746-701 G 746 Description: Error log analysis indicates a PCI SCSI adapter failure. software 746-702 G 746 Description: Error log analysis indicates a PCI SCSI adapter failure. software 746-703 G 746 Description: Error log analysis indicates a PCI SCSI adapter failure. software 746-704 G 746 Description: Error log analysis indicates a PCI SCSI adapter failure. software 746-705 G 746 Description: Error log analysis indicates a PCI SCSI adapter failure. software 746-800 G 746 Description: Error log analysis indicates a PCI SCSI adapter PTC failure. Action: Go to Chapter 7. "MAP 0050: SCSI Problems Isolation Procedure". 746-802 G 746 Description: Error log analysis indicates a PCI SCSI bus failure. Action: Go to Chapter 7. "MAP 0050: SCSI Problems Isolation Procedure". 747-212 D 747 Description: FIFO empty bit set. Action: Go to Chapter 7. "MAP 0050: SCSI 221 Problems Isolation Procedure". 747-213 D 747 Description: FIFO empty bit clear. Action: Go to Chapter 7. "MAP 0050: SCSI 221 Problems Isolation Procedure". 747-214 D 747 Description: FIFO full bit set. Action: Go to Chapter 7. "MAP 0050: SCSI 221 Problems Isolation Procedure". 747-215 D 747 Description: FIFO full bit clear. Action: Go to Chapter 7. "MAP 0050: SCSI 221 Problems Isolation Procedure". 747-216 D 747 Description: FIFO data miscompare. Action: Go to Chapter 7. "MAP 0050: SCSI 221 Problems Isolation Procedure". 747-217 D 747 Description: SCSI FIFO data miscompare. Action: Go to Chapter 7. "MAP 0050: SCSI 221 Problems Isolation Procedure". 747-218 D 747 Description: SCSI FIFO underflow. Action: Go to Chapter 7. "MAP 0050: SCSI 221 Problems Isolation Procedure". 747-219 D 747 Description: SCSI parity error. Action: Go to Chapter 7. "MAP 0050: SCSI 221 Problems Isolation Procedure". 747-220 D 747 Description: SCSI FIFO flags error. Action: Go to Chapter 7. "MAP 0050: SCSI 221 Problems Isolation Procedure". 747-221 D 747 Description: Miscompare during the write/read of the configuration register. 221 Action: Go to Chapter 7. "MAP 0050: SCSI Problems Isolation Procedure". 747-222 D 747 Description: Error during the write/read of the memory register. 221 Action: Go to Chapter 7. "MAP 0050: SCSI Problems Isolation Procedure". 747-223 D 747 Description: Miscompare during the write/read of the memory I/O register. 221 Action: Go to Chapter 7. "MAP 0050: SCSI Problems Isolation Procedure". 747-224 D 747 Description: Error reading the PCI configuration register. 221 747-225 D 747 Description: Adapter POST failed. 221 747-230 D D50 Description: Arbitration test failed. Action: Go to Chapter 7. "MAP 0050: SCSI 747 Problems Isolation Procedure". 747-231 D D50 Description: Function could not complete. Action: Go to Chapter 7. "MAP 0050: SCSI 747 Problems Isolation Procedure". 747-232 D D50 Description: SCSI bus data miscompare. Action: Go to Chapter 7. "MAP 0050: SCSI 747 Problems Isolation Procedure". 747-240 D 747 Description: No terminal power. Action: Go to Chapter 7. "MAP 0050: SCSI 221 Problems Isolation Procedure". 747-301 D 747 Description: Configuration open failed for parent bus. D50 software 747-700 G 747 Description: Error log analysis indicates a PCI SCSI adapter failure. software 747-701 G 747 Description: Error log analysis indicates a PCI SCSI adapter failure. software 747-702 G 747 Description: Error log analysis indicates a PCI SCSI adapter failure. software 747-703 G 747 Description: Error log analysis indicates a PCI SCSI adapter failure. software 747-704 G 747 Description: Error log analysis indicates a PCI SCSI adapter failure. software 747-705 G 747 Description: Error log analysis indicates a PCI SCSI adapter failure. software 747-800 G 747 Description: Error log analysis indicates a PCI SCSI adapter PTC failure. Action: Go to Chapter 7. "MAP 0050: SCSI Problems Isolation Procedure". 747-802 G 747 Description: Error log analysis indicates a PCI SCSI bus failure. Action: Go to Chapter 7. "MAP 0050: SCSI Problems Isolation Procedure". 749-xxx D 749 Description: 7331 Model 205 Tape Library. Refer to service documentation for this device. 750-100 D 750 Description: The adapter open test failed. 750-200 D 750 Description: Config register test failed. 221 750-201 D 750 Description: I/O register test failed. 221 750-202 D 750 Description: Adapter self-test failed. 221 750-300 D 256 Description: The connect test failed. 750 221 750-301 D 256 Description: Token-ring internal wrap test failure. 750 221 750-302 D 256 Description: Token-ring external wrap failure 750 221 750-303 D 256 Description: Token-ring initialization test failure 750 221 750-400 D 240 Description: The connect test failed. 256 750 221 750-401 D 240 Token-ring internal wrap test failure 256 750 221 750-402 D 240 Token-ring external wrap test failure 256 750 221 750-403 D 240 Token-ring initialization test failure 256 750 221 750-700 G 750 Description: Error Log analysis indicated a hardware failure. 221 751-101 D 751 Description: The PCI wrap test failed 227 751-102 D 751 Description: The POST indicates an adapter failure. 751-103 D 751 Description: The POST indicates an adapter channel failure. 751-104 D Cable Description: The POST indicates a defective cable. 751-105 D Backplane/ Description: The POST indicates a defective backplane or external enclosure. Ext.Encl Action: If the disk devices are located in an external enclosure, refer to the service documentation for the external enclosure. 751-106 D Disk Description: The POST indicates a disk failure. 751-107 D 751 Description: The POST indicates a firmware failure. 751-108 D 751 Description: The NVRAM test indicates an adapter firmware failure. 751-109 D 751 Description: The NVRAM test indicates an adapter failure. 751-110 D Disk Description: The disk reported a Predictive Failure Analysis error (PFA). 751-111 D Disk Description: The disk drive has been failed by the adapter. 751-112 G Disk Description: ELA indicates that the disk reported a irrecoverable equipment error. 751-113 G Disk Description: ELA indicates that the disk reported a irrecoverable data error. 757-110 D 757 Description: The Reserve command failed. 757-120 D 757 Description: The Inquiry command failed. 757-130 D 757 Description: The Load command failed. media 757-135 D 757 Description: The Unload command failed. media 757-140 D 757 Description: The Mode Select command failed. 757-150 D 757 Description: The Test Unit Ready command failed. media 757-160 D 757 Description: The Send Diagnostic command failed. media 757-169 D 757 Description: The send diagnostic command failed. media 757-170 D 757 Description: The Read, Write and Compare test failed. B88 media 757-180 D 757 Description: The Load command failed. media 757-185 D 757 Description: The Unload command failed. media 757-190 D 757 Description: The Mode Select command failed. 757-200 D 757 Description: The Test Unit Ready command failed. media 757-210 D 757 Description: The device configuration failed. B88 757-220 D 757 Description: The Release command failed. 757-230 D 757 Description: The Request Sense command failed. 757-240 D 757 Description: The Openx command failed. 757-300 D 757 Description: The device configuration failed. software 757-310 D B88 Description: SCSI adapter configuration failed. 757 software 757-320 D 757 Description: Error log analysis indicates a failure. media 757-411 D 757 Description: A reservation conflict to occurred. 757-423 B88 software 757-511 D 757 Description: The drive returned bad or to non-extended sense data. 757-523 B88 757-611 D 757 Description: An adapter or bus I/O error to occurred. 757-623 B88 software 757-711 D 757 Description: A device timeout error to occurred. 757-723 B88 software 772-098 Description: Disk drive indicates an J 772 error. B88 772-099 Description: Disk drive not found. J 772 B88 772-102 Description: An unrecoverable media error. D 772 772-104 Description: The motor failed to restart. D 772 772-105 Description: The drive did not become D 772 ready. 772-106 Description: The electronics card test D 772 failed. 772-108 Description: The bus test failed. D 772 772-110 Description: The media format is D 772 corrupted. 772-112 Description: The diagnostic test failed. D 772 772-114 Description: An unrecoverable hardware D 772 error. 772-116 Description: A protocol error. D Action: Check the levels of the device, adapter, diagnostic software, and application software to be sure they are all compatible. If you do not find a problem, call your support person. 772-117 Description: A write protect error D 772 occurred. 772-118 Description: A SCSI command time-out. D 772 B88 772-120 Description: A SCSI busy or command error. D 772 772-122 Description: A SCSI reservation conflict D 772 error. 772-124 Description: A SCSI check condition error. D 772 772-126 Description: A software error was caused D 772 by a hardware failure. B88 772-128 Description: The error log analysis G 772 indicates a hardware failure. 772-129 G D50 Description: Error log analysis indicates a SCSI bus problem. 772 B88 software 772-130 G 772 Description: Error log analysis indicates a problem reported by the disk drive's self monitoring function. 772-132 Description: A disk drive hardware error D 772 occurred. 772-134 Description: The adapter failed to D B88 configure. software 772-135 D 772 Description: The device failed to B88 configure. software 772-136 Description: The certify operation failed. D 772 772-137 D 772 Description: Unit attention condition has occurred on the Send Diagnostic command. B88 D50 773-098 Description: Disk drive indicates an J 773 error. B88 773-099 Description: Disk drive not found. J 773 B88 773-102 Description: An unrecoverable media error. D 773 773-104 Description: The motor failed to restart. D 773 773-105 Description: The drive did not become D 773 ready. 773-106 Description: The electronics card test D 773 failed. 773-108 Description: The bus test failed. D 773 773-110 Description: The media format is D 773 corrupted. 773-112 Description: The diagnostic test failed. D 773 773-114 Description: An unrecoverable hardware D 773 error. 773-116 Description: A protocol error. D Action: Check the levels of the device, adapter, diagnostic software, and application software to be sure they are all compatible. If you do not find a problem, call your support person. 773-117 Description: A write protect error D 773 occurred. 773-118 Description: A SCSI command time-out. D 773 B88 773-120 Description: A SCSI busy or command error. D 773 773-122 Description: A SCSI reservation conflict D 773 error. 773-124 Description: A SCSI check condition D 773 error. 773-126 Description: A software error was caused D 773 by a hardware failure. B88 773-128 Description: The error log analysis G 773 indicates a hardware failure. 773-129 G D50 Description: Error log analysis indicates a SCSI bus problem. 773 B88 software 773-130 G 773 Description: Error log analysis indicates a problem reported by the disk drive's self monitoring function. 773-132 Description: A disk drive hardware error D 773 occurred. 773-134 Description: The adapter failed to D B88 configure. software 773-135 D 773 Description: The device failed to B88 configure. software 773-136 Description: The certify operation failed. D 773 773-137 D 773 Description: Unit attention condition has occurred on the Send Diagnostic command. B88 D50 774-098 J 774 Description: Disk drive indicates an error. B88 774-099 Description: Disk drive not found. J 774 B88 774-102 Description: An unrecoverable media error. D 774 774-104 Description: The motor failed to restart. D 774 774-105 Description: The drive did not become D 774 ready. 774-106 Description: The electronics card test D 774 failed. 774-108 Description: The bus test failed. D 774 774-110 Description: The media format is D 774 corrupted. 774-112 Description: The diagnostic test failed. D 774 774-114 Description: An unrecoverable hardware D 774 error. 774-116 Description: A protocol error. D Action: Check the levels of the device, adapter, diagnostic software, and application software to be sure they are all compatible. If you do not find a problem, call your support person. 774-117 Description: A write protect error D 774 occurred. 774-118 Description: A SCSI command time-out. D 774 B88 774-120 Description: A SCSI busy or command error. D 774 774-122 Description: A SCSI reservation conflict D 774 error. 774-124 Description: A SCSI check condition D 774 error. 774-126 Description: A software error was caused D 774 by a hardware failure. B88 774-128 Description: The error log analysis G 774 indicates a hardware failure. 774-129 G D50 Description: Error log analysis indicates a SCSI bus problem. 774 B88 software 774-130 G 774 Description: Error log analysis indicates a problem reported by the disk drive's self monitoring function. 774-132 Description: A disk drive hardware error D 774 occurred. 774-134 Description: The adapter failed to D B88 configure. software 774-135 D 774 Description: The device failed to B88 configure. software 774-136 Description: The certify operation failed. D 774 774-137 D 774 Description: Unit attention condition has occurred on the Send Diagnostic command. B88 D50 775-001 D 775 Description: "NO" to color panel 227 Monitor 775-002 D 775 Description: "NO" to cursor panel Monitor 775-007 D Info code Description: The EMC_SCROLLING_17_H_TEST failed 775-009 D Info code Description: The EMC_SCROLLING_21_H_TEST failed 775-064 D 775 Description: TRIO64V+_TIMEOUT 227 775-101 D 775 Description: Color miscompare 227 775-102 D 775 Description: Clipping error 227 775-103 D 775 Description: Rectangle fill test failed 227 775-128 D software Description: MALLOC_ERROR 775 775-161 D software Description: Loop count value in rules file is zero 775-191 D 775 Description: Red screen error 227 775-193 D 775 Description: Green screen error 227 775-1FF D 775 Description: Rectangle fill test failed 227 775-201 D 775 Description: Color miscompare 227 775-202 D 775 Description: Clipping error 227 775-203 D 775 Description: Image transfer across Plane Test failed 227 775-211 D software Description: INTERNAL_ERROR_DATA_SIZE 775-212 D software Description: INTERNAL_ERROR_NO_ACCESS 775-215 D 775 Description: Black screen error 227 775-217 D 775 Description: 9 x 7 Cross hatch grid failed. 227 775-233 D software Description: OPEN_RCM_ERROR 775-234 D software Description: IOCTL_GSC_HANDLE_FAILED 775-235 D software Description: AIXGSC_MAKE_GP_FAILED 775-236 D software Description: AIXGSC_UNMAKE_GP_FAILED 775-237 D software Description: DEVICE_BUSY_ERROR 775-241 D Info code Description: The SCROLLING_17_H_TEST failed. 775-263 D Info code Description: The EMC_SCROLLING_21_H_TEST failed 775-2FF D 775 Description: Image transfer across Plane Test failed 227 775-301 D 775 Description: A write of "0x00" to the palette register failed 227 775-302 D 775 Description: A write of "0x15" to the palette register failed 227 775-303 D 775 Description: A write of "0x2A" to the palette register failed 227 775-304 D 775 Description: A write of "0x3F" to the palette register failed 227 775-305 D 775 Description: The test of the palette registers failed 227 775-3FF D 775 Description: The test of the palette registers failed 227 775-401 D 775 Description: Frame buffer base address inconsistent 227 775-402 D 775 Description: VRAM inaccessible 227 775-403 D 775 Description: Miscompare found in VRAM 227 775-404 D 775 Description: The test of the VRAM failed 227 775-447 D 775 Description: Green screen error 227 775-449 D 775 Description: Blue Screen error 227 775-471 D 775 Description: 9 x 7 Cross hatch grid failed. 227 775-473 D 775 Description: 11 x 9 Cross hatch grid failed. 227 775-495 D Info code Description: The SCROLLING_17_H_TEST failed. 775-497 D Info code Description: The SCROLLING_21_H_TEST failed. 775-4FF D 775 Description: The test of the VRAM failed 227 775-501 D 775 Description: Color miscompare 227 775-502 D 775 Description: Clipping error 227 775-503 D 775 Description: Direct Frame Buffer test failed 227 775-5FF D 775 Description: Direct Frame Buffer test failed 227 775-601 D 775 Description: Video Stream Register test failed 227 775-602 D 775 Description: Video Stream hardware test failed 227 775-6FF D 775 Description: Video Stream hardware test failed 227 775-701 D 775 Description: 0 Degree Short Stroke Draw failed 227 775-702 D 775 Description: 45 Degree Short Stroke Draw failed 227 775-703 D 775 Description: Blue Screen error, or 90 Degree Short Stroke Draw failed 227 775-704 D 775 Description: 135 Degree Short Stroke Draw failed 227 775-705 D 775 Description: White screen error, or 180 Degree Short Stroke Draw failed 227 775-706 D 775 Description: 225 Degree Short Stroke Draw failed 227 775-707 D 775 Description: 270 Degree Short Stroke Draw failed 227 775-708 D 775 Description: 315 Degree Short Stroke Draw failed 227 775-709 D 775 Description: Short Stroke Vector Function test failed 227 775-727 D 775 Description: 11 x 9 Cross hatch grid failed. 227 775-750 D Info code Description: The SCROLLING_21_H_TEST failed. 775-753 D Info code Description: The EMC_SCROLLING_17_H_TEST failed 775-7FE D 775 Description: Short Stroke Vector Function test failed 227 775-7FF D software Description: Bad vector detected 775 227 775-801 D 775 Description: Color for PatBlt thru screen failed 227 775-802 D 775 Description: Clipping for PatBlt thru screen failed 227 775-803 D 775 Description: Color for PatBlt Across screen failed 227 775-804 D 775 Description: Clipping for PatBlt Across screen failed 227 775-805 D 775 Description: Pattern Fill Across the Plane test failed 227 775-8FF D 775 Description: Pattern Fill Across the Plane test failed 227 775-901 D 775 Description: Color miscompare of white boxes detected 227 775-902 D 775 Description: Clipping error of white boxes detected 227 775-903 D 775 Description: Color miscompare of color bars detected 227 775-904 D 775 Description: Clipping error of white boxes detected 227 775-905 D 775 Description: Color miscompare of white boxes detected 227 775-906 D 775 Description: Clipping error of white boxes detected 227 775-907 D 775 Description: Color miscompare of white boxes detected 227 775-908 D 775 Description: Clipping miscompare of white boxes detected 227 775-909 D 775 Description: The Area fill test (color bars) failed 227 775-9FF D 775 Description: The Area fill test (color bars) failed 227 775-937 D 775 Description: Red screen error 227 775-959 D 775 Description: White screen error 227 775-961 D 775 Description: Black screen error 227 775-A01 D 775 Description: Color miscompare of horizontal top line 227 775-A02 D 775 Description: Clipping error of horizontal top line 227 775-A03 D 775 Description: Color miscompare of vertical right line 227 775-A04 D 775 Description: Clipping error of vertical right line 227 775-A05 D 775 Description: Color miscompare of horizontal bottom line 227 775-A06 D 775 Description: Clipping error of horizontal bottom line 227 775-A07 D 775 Description: Color miscompare of vertical left line 227 775-A08 D 775 Description: Clipping error of vertical left line 227 775-A09 D 775 Description: Color miscompare of horizontal center line 227 775-A0A D 775 Description: Clipping error of horizontal center line 227 775-A0B D 775 Description: Color miscompare of vertical center line 227 775-A0C D 775 Description: Clipping error of vertical center line 227 775-A0D D 775 Description: Reserved 227 775-A0F D 775 Description: Reserved 227 775-A10 D 775 Description: Color miscompare of textured top line 227 775-A11 D 775 Description: Clipping error of textured top line 227 775-A12 D 775 Description: Line Drawing Function test failed 227 775-AFF D 775 Description: Line Drawing Function test failed 227 775-B01 D 775 Description: Rectangle Area Color miscompare detected 227 775-B02 D 775 Description: Rectangle Area Clip error detected 227 775-B03 D 775 Description: Clipped Area Horizontal color miscompare (background line color wrong) 227 775-B04 D 775 Description: Clipped Area Horizontal clip miscompare (clip of background line wrong) 227 775-B05 D 775 Description: Clipped Area Vertical color miscompare (background line color wrong) 227 775-B06 D 775 Description: Clipped Area Vertical clip error (clip of background line wrong) 227 775-B07 D 775 Description: The clipping function test failed. 227 775-BFF D 775 Description: The clipping function test failed. 227 775-C01 D 775 Description: The BIOS read failed. 227 775-C02 D 775 Description: The BIOS function test failed. 227 775-CFF D 775 Description: The BIOS function test failed. 227 775-D01 D 775 Description: The HW cursor function test failed. 227 775-DFF D 775 Description: The HW cursor function test failed. 227 776-104 D D46 Description: Connect Test Failure 776-105 D D46 Description: Wrap Test Failure 776-106 D D46 Description: Wrap Test Failure 776-201 D 776 Description: Configuration Register Test Failure 221 776-202 D 776 Description: I/O Test Failure 221 776-203 D 776 Description: Adapter On-Card Test Failure 221 776-204 D 776 Description: Connect Test Failure 221 776-205 D 776 Description: Wrap Test Failure 221 776-206 D 776 Description: Wrap Test Failure 221 776-304 D D46 Description: Connect Wrap Test Failure 776 221 776-305 D D46 Description: Wrap Test Failure 776 221 776-306 D D46 Description: Wrap Test Failure 776 221 776-404 D 240 Description: Connect Test Failure D46 776 221 776-405 D 240 Description: Wrap Test Failure D46 776 221 776-406 D 240 Description: Wrap Test Failure. D46 776 221 776-414 F 240 Description: Connect Test Failure. This failure occurs if not connected to a D46 functional Token-Ring network. Action: Run advanced diagnostics for this 776 resource to obtain correct problem isolation. 221 776-415 F 240 Description: Wrap Test Failure. This failure occurs if not connected to a D46 functional Token-Ring network. Action: Run advanced diagnostics for this 776 resource to obtain correct problem isolation. 221 776-416 F 240 Description: Wrap Test Failure. This failure occurs if not connected to a D46 functional Token-Ring network. Action: Run advanced diagnostics for this 776 resource to obtain correct problem isolation. 221 776-702 G 776 Description: ELA indicates a Token-Ring adapter check. 221 776-703 G 776 Description: ELA indicates that the Token-Ring device driver has experienced a 221 DMA failure 776-704 G 776 Description: ELA indicates that the Token-Ring device driver has experienced a 221 PCI bus failure 776-705 G 776 Description: ELA indicates that the Token-Ring device driver has seen a 221 Programmed I/O (PIO) failure. 777-201 D 777 Description: Configuration Register Test Failure 221 777-202 D 777 Description: I/O Test Failure 221 777-203 D 777 Description: Adapter initialization test failure 221 777-204 D 777 Description: Internal wrap test failure 221 777-205 D 777 Description: Internal wrap test failure 221 777-206 D 777 Description: External wrap (10Mbps) test failure 221 777-207 D 777 Description: Internal wrap test failure 221 777-208 D 777 Description: External wrap (100Mbps) test failure 221 777-701 G 777 Description: Error log analysis indicates that the adapter is not responding to 221 initialization commands. 777-702 G 777 Description: Error Log Analysis indicates that the device driver has detected a PIO 221 error which it was unable to correct. 777-703 G 777 Description: Error log analysis indicates that the adapter has been shut down due to 221 an unrecoverable error. 777-704 G 777 Description: Error Log Analysis indicates a problem with the EEPROM on the adapter 221 780-101 D 780 Description: Adapter logic test failure. 227 780-102 D 780 Description: Adapter logic test failure. 780-109 D 780 Description: Adapter channel Input/Output test failure. 780-113 D 780 Description: Adapter Serial Communication Controller (SCC) test failure. 780-114 D 780 Description: Adapter logic test failure. 227 780-120 D 780 Description: Adapter could not be detected or configured. 227 software 780-140 D 271 Description: An error was found with the X.21 interface adapter cable. 780 780-150 D 272 Description: An error was found with the X.24 interface adapter cable. 780 780-160 D 273 Description: An error was found with the X.35 interface adapter cable. 780 780-170 D 780 Description: The adapter hardware failed. 780-180 D 780 Description: The adapter hardware failed. 780-190 D 780 Description: The adapter hardware failed. 780-210 D 780 Description: An error was found on the adapter. 185 780-211 D 780 Description: The adapter card POST test failed. 227 780-230 D 780 Description: The adapter card hardware failed. 780-232 D 849 Description: The adapter card hardware failed. 227 780-240 D 780 Description: The adapter card hardware failed. 780-250 D 185 Description: An error was found on the adapter. 780 780-260 D 780 Description: The adapter card hardware failed. 780-270 D 780 Description: The adapter card hardware failed. 780-280 D 780 Description: The adapter card hardware failed. 780-290 D 780 Description: The adapter card hardware failed. 780-300 G 780 Description: An adapter error was found during error log analysis. 780-310 G 780 Description: An adapter error was found during error log analysis. 185 780-320 G 780 Description: An adapter error was found during error log analysis. 227 780-330 G 780 Description: Error log analysis indicates a hardware problem. 227 780-400 D 780 Description: A software error was caused by a hardware failure. 227 780-700 D 780 Description: The adapter failed to configure. 227 software 780-720 D 780 Description: Cable wrap test failed. 780-721 D 780 Description: Port wrap test failed. 780-722 D 780 Description: Cable wrap test failed. 781-101 D 781 Description: ROS POST adapter software initialization error. 227 781-102 D 781 Description: Extended DRAM SIP test failed. 781-103 D 781 Description: ROS checksum test failed. 781-104 D 781 Adapter download diagnostics failed 227 781-105 D 781 Description: Memory size test failed. 227 781-106 D 781 Description: Interface ID test failed. 227 781-107 D 781 Description: EIB ID test failed. 227 781-108 D 781 Description: ROS version test failed. 227 781-109 D 781 Description: DUSCC register test failed. 781-111 D 781 Description: DMA register test failed. 781-112 D 781 Description: X.21 PAL test failed. 781-113 D 781 Description: External wrap test failed. 781-114 D 781 Description: Twin tail logic test failed. 227 781-116 D 254 Description: The RS-232 cable wrap test failed. 781-117 D 253 Description: The RS-422A cable wrap test failed. 781-118 D 257 Description: The V.35 cable wrap test failed. 781-119 D 260 Description: The X.21 cable wrap test failed. 781-120 D 781 Description: The adapter was not detected or could not be configured. test failed. 227 software 781-121 D 781 Description: The 4-port jumper cable assembly wrap test failed. 227 software 781-200 G 781 Description: The error log analysis indicates the adapter failed. 781-221 G 781 Description: The error log analysis indicates the adapter hardware failed. 227 781-231 D 855 Description: No interface card detected. 227 781-501 D B77 Description: The power-on self-test (POST) failed. B69 227 781-502 D B77 Description: The memory module failed. 781-503 D 781 Description: Adapter hardware failure. 227 781-504 D B69 Description: Adapter hardware failure. 781-505 D B71 Description: Adapter hardware failure. B69 781-506 D B72 Description: Adapter hardware failure. B69 781-507 D B73 Description: Adapter hardware failure. B69 781-508 D B74 Description: Adapter hardware failure. B69 781-516 D B77 Description: Adapter Test Failure B69 781-517 D B69 Description: Adapter Test Failure B77 781-720 D 258 4-port multiprotocol cable 781 783-110 D 783 Description: The Reserve command failed. 783-120 D 783 Description: The Inquiry command failed. 783-130 D 783 Description: The Load command failed. media 783-135 D 783 Description: The Unload command failed. media 783-140 D 783 Description: The Mode Select command failed. 783-150 D 783 Description: The Test Unit Ready command failed. media 783-160 D 783 Description: The Send Diagnostic command failed. media 783-169 D 783 Description: The send diagnostic command failed. media 783-170 D 783 Description: The Read, Write and Compare test failed. B88 media 783-180 D 783 Description: The Load command failed. media 783-185 D 783 Description: The Unload command failed. media 783-190 D 783 Description: The Mode Select command failed. 783-200 D 783 Description: The Test Unit Ready command failed. media 783-210 D 783 Description: The device configuration failed. B88 783-220 D 783 Description: The Release command failed. 783-230 D 783 Description: The Request Sense command failed. 783-240 D 783 Description: The Openx command failed. 783-300 D 783 Description: The device configuration failed. software 783-310 D B88 Description: SCSI adapter configuration failed. 783 software 783-320 G 783 Description: Error log analysis indicates a failure. media 783-411 D 783 Description: A reservation conflict to occurred. 783-423 B88 software 783-511 D 783 Description: The drive returned bad or to non-extended sense data. 783-523 B88 783-611 D 783 Description: An adapter or bus I/O error to occurred. 783-623 B88 software 783-711 D 783 Description: A device timeout error to occurred. 783-723 B88 software 784-102 D 784 Description: An unrecoverable media error. 784-104 D 784 Description: The motor failed to restart. 784-105 D 784 Description: The drive did not become ready. 784-106 D 784 Description: The electronics card test failed. 784-108 D 784 Description: The bus test failed. 784-110 D 784 Description: The media format is corrupted. 784-112 D 784 Description: The diagnostic test failed. 784-114 D 784 Description: An unrecoverable hardware error. 784-116 D Description: A protocol error. Action: Check the levels of the device, adapter, diagnostic software, and application software to be sure they are all compatible. If you do not find a problem, call your support person. 784-117 D 784 Description: A write protect error occurred. 784-118 D 784 Description: A SCSI command time-out. B88 784-120 D 784 Description: A SCSI busy or command error. 784-122 D 784 Description: A SCSI reservation conflict error. 784-124 D 784 Description: A SCSI check condition error. 784-126 D 784 Description: A software error was caused by a hardware failure. B88 784-128 G 784 Description: The error log analysis indicates a hardware failure. 784-129 G D50 Description: Error log analysis indicates a SCSI bus problem. 784 B88 software 784-130 G 784 Description: Error log analysis indicates a problem reported by the disk drive's self monitoring function. 784-132 D 784 Description: A disk drive hardware error occurred. 784-134 D B88 Description: The adapter failed to configure. software 784-135 D 784 Description: The device failed to B88 configure. software 784-136 D 784 Description: The certify operation failed. 784-137 D 784 Description: Unit attention condition has occurred on the Send Diagnostic command. B88 D50 785-111 D 785 Could not do the test because the device driver detected a hardware error. 227 785-114 D 785 The register verification test failed. 785-121 D 785 Could not do the test because the device driver detected a hardware error. 227 785-122 D 785 The data wrap communication test failed. 227 785-123 D 785 The modem control line test failed. 227 785-124 D 785 The memory test failed. 785-151 D 785 Could not do the test because the device driver detected a hardware error. D57 785-152 D 785 The data wrap communication test failed. D57 785-153 D 785 The modem control line test failed. D57 785-171 D 259 Could not do the test because the device driver detected a hardware error. 785-172 D 259 The data wrap communication test failed. 785-173 D 259 The modem control line test failed. 785-181 D 261 Could not do the test because the device driver detected a hardware error. 785-182 D 261 The data wrap communication test failed. 785-183 D 261 The modem control line test failed. 785-251 D 785 Could not perform because the device driver detected a hardware error. D57 785-252 D 785 The data wrap communication test failed. D57 785-253 D 785 The modem control line test failed. D57 785-271 D 785 Could not perform because the device driver detected a hardware error. D57 785-272 D 785 The data wrap communication test failed. D57 785-273 D 785 The modem control line test failed. D57 785-281 D 785 Could not perform because the device driver detected a hardware error. D57 785-282 D 785 The data wrap communication test failed. D57 785-283 D 785 The modem control line test failed. D57 785-481 D D57 Could not do the test because the device driver detected a hardware error. 785-482 D D57 The data wrap communication test failed. 785-483 D D57 The modem control line test failed. 785-901 D software Description: An unexpected error occurred that can be attributed to software or to 785 hardware. 785-920 Action: Run diagnostics from a source other than from the disk or a network. If the same error occurs or if the original SRN was not obtained from disk or a network based diagnostics, use Chapter 12. "MAP 0210: General Problem Resolution" with a FFC of 785; otherwise, suspect a software problem. 785-921 D 785 Description: The adapter failed to configure software 785-922 D software Description: An unexpected error occurred that can be attributed to software or to 785 hardware. 785-924 Action: Run diagnostics from a source other than from the disk or a network. If the same error occurs or if the original SRN was not obtained from disk or a network based diagnostics, use Chapter 12. "MAP 0210: General Problem Resolution" with a FFC of 785; otherwise, suspect a software problem. 785-925 D 785 Description: The adapter failed to configure software 785-926 D software Description: An unexpected error occurred that can be attributed to software or to 785 hardware. 785-943 Action: Run diagnostics from a source other than from the disk or a network. If the same error occurs or if the original SRN was not obtained from disk or a network based diagnostics, use Chapter 12. "MAP 0210: General Problem Resolution" with a FFC of 785; otherwise, suspect a software problem. 786-200 D 786 Description: Initiation failed D96 Note: You must determine which of the first two FFCs is installed in the system unit. 227 786-210 D 786 Description: The adapter test failed 227 786-211 D D96 Description: The adapter test failed 227 786-220 D 786 Description: The display test failed Cable Monitor 786-221 D D96 Description: The display test failed Cable Monitor 786-710 D 786 Description: The ELA indicates HW failure 227 786-711 D D96 The ELA indicates HW failure 227 787-100 D 787 GXT500P Graphics Adapter 787-101 D 787 Description: GXT500P Graphics Adapter 227 787-1AA D 787 Description: GXT500P Graphics Adapter RGB Cable Display 787-1xx D 787 Description: GXT500P Graphics Adapter 787-200 D D95 Description: GXT550P Graphics Adapter 787-201 D D95 Description: GXT550P Graphics Adapter 227 787-2AA D D95 Description: GXT550P Graphics Adapter RGB Cable Display 787-2xx D D95 Description: GXT550P Graphics Adapter 788-001 D 788 Description: Adapter Error 227 788-002 D software Description: System Error 788 788-003 D software Description: System Error 788 788-004 D 788 Description: System Error software 789-101 D 789 Description: Failed to release the device. 789-102 D 789 Description: Failed to reserve the device. 789-103 D 789 Description: The device motor failed to start. 789-104 D 789 Description: Failed to make the device ready. 789-105 D 789 Description: Failed to get the inquiry data. 789-106 D 789 Description: The Prevent Media Removal command failed. 789-107 D 789 Description: The Allow Media Removal command failed. 789-200 D 789 Description: The optical disk failed to load. Optical Disk Action: Change the media. Run diagnostics on the changed media in System Verification mode. If the error reoccurs use Chapter 12. "MAP 0210: General Problem Resolution"; otherwise, replace the media. 789-201 D 789 Description: Failed to unload the optical disk. Optical Disk Action: Change the media. Run diagnostics on the changed media in System Verification mode. If the errors reoccur use Chapter 12. "MAP 0210: General Problem Resolution"; otherwise, replace the media. 789-202 D 789 Description: The diagnostic test failed. Action: Change the media. Run diagnostics Optical Disk on the changed media in System Verification mode. If errors do not reoccur, replace the media; otherwise, run the drive cleaning procedures if applicable and rerun the diagnostics. If errors reoccur, or the drive does not support the cleaning procedures use Chapter 12. "MAP 0210: General Problem Resolution". 789-204 D 789 Description: The device failed to configure. B88 789-205 D 789 Description: The Test Unit Ready command failed. Optical Disk Action: Change the media. Run diagnostics on the changed media in System Verification mode. If the error reoccurs, use Chapter 12. "MAP 0210: General Problem Resolution"; otherwise, replace the media. 789-206 D 789 Description: The random write, read and compare test failed. Optical Disk Action: Change the media. Run diagnostics on the changed media in System Verification mode. If the errors do not reoccur, replace the media; otherwise, run the drive cleaning procedures if applicable, and rerun diagnostics. If the errors reoccur, or the drive does not support cleaning procedures, use Chapter 12. "MAP 0210: General Problem Resolution". 789-207 D 789 Description: A hardware error occurred. Action: Change the media. Run diagnostics Optical Disk on the changed media in System Verification mode. If the errors do not reoccur, replace the media; otherwise, run the drive cleaning procedures if applicable, and rerun diagnostics. If the errors reoccur, or the drive does not support cleaning procedures, use Chapter 12. "MAP 0210: General Problem Resolution". 789-208 D 789 Description: The Mode Sense command failed. Optical Disk Action: Change the media. Run diagnostics on the changed media in System Verification mode. If the errors do not reoccur, replace the media; otherwise, run the drive cleaning procedures if applicable, and rerun diagnostics. If the errors reoccur, or the drive does not support cleaning procedures, use Chapter 12. "MAP 0210: General Problem Resolution". 789-209 D 789 Description: The Mode Select command failed. Optical Disk Action: Change the media. Run diagnostics on the changed media in System Verification mode. If the errors do not reoccur, replace the media; otherwise, run the drive cleaning procedures if applicable, and rerun diagnostics. If the errors reoccur, or the drive does not support cleaning procedures, use Chapter 12. "MAP 0210: General Problem Resolution". 789-300 D 789 Description: A SCSI reservation conflict has occurred. B88 software 789-400 D 789 Description: A SCSI command time out has occurred. B88 Cables software 789-401 D Optical Disk Description: An unknown error has occurred. D50 B88 software 789-402 D Optical Disk Description: Unit attention condition has occurred. D50 B88 software 789-600 G Optical Disk Description: ELA indicates that the spare sectors on the disk are exhausted. Action: Backup the media and replace it. Note: Use the time when the error occurred and the "Spare Sector Availability" service aid to identify the disk that has the error. 789-700 G 789 Description: The ELA indicates an equipment error. Optical Disk Action: Run diagnostics in System Verification mode to isolate the problem. If errors are reported, use Chapter 12. "MAP 0210: General Problem Resolution"; otherwise, the error is due to faulty media. Backup the media and then replace it. Note: Use the time when the error occurred to identify the faulty media. 789-701 G Optical Disk Description: ELA indicates an irrecoverable data error. 789 Action: Run diagnostics in System Verification mode to isolate the problem. If errors are reported, use Chapter 12. "MAP 0210: General Problem Resolution"; otherwise, the error is due to faulty media. Backup the media and then replace it. Note: Use the time when the error occurred to identify the faulty media. 789-702 G 789 Description: ELA indicates that the adapter detected an error. B88 Action: Use the 7209 Installation and Service Guide. If the unit checks out to be Cables good, use Chapter 12. "MAP 0210: General Problem Resolution". 790-101 D 790 Description: Configuration Register Test failure 790-102 D 790 Description: I/O test failure 790-103 D 790 Description: Adapter initialization test failure 790-104 D 790 Description: Internal wrap test failure 790-105 D 790 Description: Internal wrap test failure 790-106 D 790 Description: External wrap (10Mbps) test failure 790-107 D 790 Description: Internal wrap test failure 790-108 D 790 Description: External wrap (100Mbps) test failure 790-109 D 790 Description: External wrap (10Mbps) test failure 790-121 D 790 Description: Configuration register test failure 790-122 D 790 Description: I/O register test failure 790-124 D 790 Description: Internal loopback test failure 790-125 D 790 Description: Internal loopback test failure 790-126 D 790 Description: External loopback test failure 790-150 D B08 Description: 10Base-T transceiver test failure 790-151 D B09 Description: 10Base-2 transceiver test failure 790-223 D 790 Description: Device configuration failure software 790-224 D B08 Description: 10 Base-T transceiver test failure 790 790-225 D B09 Description: 10 Base-2 transceiver test failure 790 790-250 D B08 Description: 10 Base-T transceiver test failure 790 790-251 D B09 Description: 10 Base-2 transceiver test failure 790 790-701 G 790 Description: Error Log Analysis indicates that the adapter is not responding to initialization commands. 790-702 G 790 Description: Error Log Analysis indicates that the device driver has detected a PIO error which it was unable to correct. 790-703 G 790 Description: Error Log Analysis indicates that the adapter has been shutdown due to an unrecoverable error. 790-704 G 790 Description: Error Log Analysis indicates a problem with EEPROM on the adapter. 790-720 G 790 Description: Error log analysis indicates a hardware problem software 791-098 Description: The disk drive indicates an J 791 error. B88 791-099 Description: The disk drive not found. J 791 B88 791-102 Description: An unrecoverable media error D 791 occurred. 791-104 Description: The motor failed to restart. D 791 791-105 Description: The drive did not become D 791 ready. 791-106 Description: The electronics card test D 791 failed. 791-108 Description: The bus test failed. D 791 791-110 Description: The media format is D 791 corrupted. 791-112 Description: The diagnostic test failed. D 791 791-114 Description: An unrecoverable hardware D 791 error. 791-116 Description: A protocol error. D Action: Check the levels of the device, adapter, diagnostic software, and application software to be sure they are all compatible. If you do not find a problem, call your support person. 791-117 Description: A write protect error D 791 occurred. 791-118 Description: A SCSI command time-out D 791 occurred. B88 791-120 Description: A SCSI busy or command D 791 error. 791-122 Description: A SCSI reservation conflict D 791 error. 791-124 Description: A SCSI check condition error D 791 occurred. 791-126 Description: A software error was caused D 791 by a hardware failure. B88 791-128 Description: The error log analysis G 791 indicates a hardware failure. 791-129 G D50 Description: Error log analysis indicates a SCSI bus problem. 791 B88 software 791-130 G 791 Description: Error log analysis indicates a problem reported by the disk drive's self monitoring function. 791-132 D 791 Description: A disk drive hardware error occurred. 791-134 D B88 Description: The adapter failed to configure. software 791-135 D 791 Description: The device failed to configure. B88 software 791-136 D 791 Description: The certify operation failed. 791-137 D 791 Description: Unit attention condition has occurred on the Send Diagnostic command. B88 D50 792-098 Description: The disk drive indicates an J 792 error. B88 792-099 Description: The disk drive not found. J 792 B88 792-102 Description: An unrecoverable media error D 792 occurred. 792-104 Description: The motor failed to restart. D 792 792-105 Description: The drive did not become D 792 ready. 792-106 Description: The electronics card test D 792 failed. 792-108 Description: The bus test failed. D 792 792-110 Description: The media format is D 792 corrupted. 792-112 Description: The diagnostic test failed. D 792 792-114 Description: An unrecoverable hardware D 792 error. 792-116 Description: A protocol error. D Action: Check the levels of the device, adapter, diagnostic software, and application software to be sure they are all compatible. If you do not find a problem, call your support person. 792-117 Description: A write protect error D 792 occurred. 792-118 Description: A SCSI command time-out D 792 occurred. B88 792-120 Description: A SCSI busy or command D 792 error. 792-122 Description: A SCSI reservation conflict D 792 error. 792-124 Description: A SCSI check condition error D 792 occurred. 792-126 Description: A software error was caused D 792 by a hardware failure. B88 792-128 Description: The error log analysis G 792 indicates a hardware failure. 792-129 G D50 Description: Error log analysis indicates a SCSI bus problem. 792 B88 software 792-130 G 792 Description: Error log analysis indicates a problem reported by the disk drive's self monitoring function. 792-132 Description: A disk drive hardware error D 792 occurred. 792-134 Description: The adapter failed to D B88 configure. software 792-135 D 792 Description: The device failed to B88 configure. software 792-136 D 792 Description: The certify operation failed. 792-137 D 792 Description: Unit attention condition has occurred on the Send Diagnostic command. B88 D50 793-098 J 793 Description: The disk drive indicates an error. B88 793-099 J 793 Description: The disk drive not found. B88 793-102 D 793 Description: An unrecoverable media error occurred. 793-104 Description: The motor failed to restart. D 793 793-105 Description: The drive did not become D 793 ready. 793-106 Description: The electronics card test D 793 failed. 793-108 Description: The bus test failed. D 793 793-110 Description: The media format is D 793 corrupted. 793-112 Description: The diagnostic test failed. D 793 793-114 Description: An unrecoverable hardware D 793 error. 793-116 Description: A protocol error. D Action: Check the levels of the device, adapter, diagnostic software, and application software to be sure they are all compatible. If you do not find a problem, call your support person. 793-117 Description: A write protect error D 793 occurred. 793-118 Description: A SCSI command time-out D 793 occurred. B88 793-120 Description: A SCSI busy or command D 793 error. 793-122 Description: A SCSI reservation conflict D 793 error. 793-124 Description: A SCSI check condition error D 793 occurred. 793-126 Description: A software error was caused D 793 by a hardware failure. B88 793-128 G 793 Description: The error log analysis indicates a hardware failure. 793-129 G D50 Description: Error log analysis indicates a SCSI bus problem. 793 B88 software 793-130 G 793 Description: Error log analysis indicates a problem reported by the disk drive's self monitoring function. 793-132 Description: A disk drive hardware error D 793 occurred. 793-134 Description: The adapter failed to D B88 configure. software 793-135 D 793 Description: The device failed to B88 configure. software 793-136 Description: The certify operation D 793 failed. 793-137 D 793 Description: Unit attention condition has occurred on the Send Diagnostic command. B88 D50 795-201 D 795 Description: Config register test failure 795-202 D 795 Description: PROM check test failure 795-203 D 795 Description: Timer and IRQ test failure 795-204 D 795 Description: Adapter RAM check failure 795-205 D 795 Description: ASIC test failure 795-206 D 795 Description: High memory (ISA) test failure 795-207 D 795 Description: RAM check via DMA test failure 795-208 D 795 Description: FORMAC register test failure 795-209 D 795 Description: PLC1 test failure 221 795-210 D 795 Description: PLC2 test failure 795-211 D 795 Description: FORMAC Ring_Op test failure 795-212 D 795 Description: Send long frame test failure 795-213 D 795 Description: Restricted Token Monitor test failure 795-214 D 795 Description: Receive queue handling test failure 795-215 D 795 Description: FORMAC loopback test failure 795-216 D 795 Description: FORMAC loopback with master access test failure 795-217 D 795 Description: DMA measurement test failure 795-218 D 795 Description: Special test failure 795-219 D 795 Description: Bypass test failure 795-301 D 795 Description: PLC1 FDDI external wrap failure 795-302 D 795 Description: PLC2 FDDI external wrap failure 795-303 D 795 Description: Send long frame FDDI external wrap failure 795-304 D 795 Description: FORMAC loopback external wrap failure 795-700 D 795 Description: Error log analysis indicates hardware failure 799-101 D 2C3 Description: External wrap test failed on port 0 799 799-102 D 2C3 Description: External wrap test failed on port 1 799 799-201 D 799 Description: Internal adapter test failed 227 799-202 D 799 Description: External wrap test failed on port 0 227 799-203 D 799 Description: External wrap test failed on port 1 227 799-204 D 2C3 Description: External wrap test failed on port 0 799 799-205 D 2C3 Description: External wrap test failed on port 1 799 799-206 D 2C3 Description: External wrap test failed on port 0 799 software 799-207 D 2C3 Description: External wrap test failed on port 1 799 software 799-301 D 799 Description: Internal adapter test failed 227 software 799-302 D 799 Description: External wrap test failed on port 0 227 software 799-303 D 799 Description: External wrap test failed on port 1 227 software 799-304 D 2C3 Description: External wrap test failed on port 0 799 software 799-305 D 2C3 Description: External wrap test failed on port 1 799 software 799-700 D 799 Description: Error log analysis indicates a hardware problem software 7C1-101 D 7C1 Description: Audio Subsystem failed software 7C1-102 D 7C1 Description: CS4232 Failed 7C1-103 D 7C1 Description: Clock control failed 7C1-107 D 7C1 Description: SoundBlaster interface failed 7C1-108 D 7C1 Description: Loop back failed 7C1-109 D 7C1 Description: CODEC ID invalid 7C1-117 D D97 Description: Internal speaker failed 801-101 C Description: The diagnostics did not detect an installed resource. to Action: Ensure supplemental diskettes have been read, if applicable, then use Chapter 801-102 18. "MAP 0290: Missing Resource Problem Resolution". 802-787 C 787 Description: The diagnostics did not detect an installed resource. D95 802-78C C Description: A system bus problem exists. Action: Use Chapter 11. "MAP 0080 System Bus Problem Isolation". 802-xxx C xxx Description: The diagnostics did not detect an installed resource. Note: To obtain the FFC substitute the last three digits of the SRN for xxx. (The substituted xxx is the FFC.) 803-xxx D Use the xxx Description: An error occurred while running the diagnostics. (See note number Action: Run nondisk-based diagnostics where possible. If this SRN was generated from in Action the nondisk-based diagnostic package, or it is not possible to use the nondisk-based column.) package, go to Chapter 15. "MAP 0250: Unexpected System Halts During Diagnostics". If the problem occurs only from disk-or server-based diagnostics, suspect a software problem. Notes: 1. If your 803-xxx SRN is listed in this section, use the procedure for that SRN instead of this one. 2. If the xxx FFC is not listed in the FFC list, Use MAP 1540 to determine the failing FRU. 804-111 D 804 Description: Unable to reserve device. B88 804-112 D 804 Description: Unable to do configuration. B88 804-113 D 804 Description: Unable to open the device driver. B88 804-121 D 804 Description: The CD-ROM drive indicates an error. 804-122 D 804 Description: The CD-ROM drive indicates an error. 804-123 D 804 Description: The CD-ROM drive indicates an error. 804-125 D 804 Description: The CD-ROM drive indicates an error. B88 804-126 D 804 Description: The CD-ROM drive indicates an error. 804-127 D 804 Description: The CD-ROM drive indicates an error. 804-128 D 804 Description: The CD-ROM drive indicates an error. 804-129 D 804 Description: The CD-ROM drive indicates an error. 804-150 D Media Description: A media error was detected. 804 804-151 D 804 Description: A command timeout was detected. B88 804-152 D 804 Description: A command reservation conflict was detected. 804-162 D 804 Description: The CD-ROM drive indicates an error. 804-171 D 804 Description: Unable to reserve device. 804-172 D 804 Description: Unable to do configuration. 804-173 D 804 Description: Unable to open device driver. 804-175 D 804 Description: The CD-ROM drive indicates an error. 804-198 D 804 Description: Undefined error detected. B88 804-199 D 804 Description: Undefined error detected. 804-211 D 804 Description: The LED test failed. 804-281 D 804 Description: No tone during audio test. 804-301 G 804 Description: Errors found during ELA. 804-302 G 804 Description: Errors found during ELA. B88 804-xxx H Use the Description: An unexpected halt occurred while running the diagnostics. xxx Note: If your 804-xxx SRN is listed in this number section, use the procedure for that SRN instead of this one. Action: Use Chapter 15. "MAP 0250: Unexpected System Halts During Diagnostics". 805-110 G D67 Description: Error log analysis indicates a machine check due to uncorrectable memory error. Action: Use Chapter 14. "MAP 0240: Memory Problem Resolution". 805-111 G D83 Description: Error log analysis indicates a machine check due to uncorrectable memory error. Action: Use Chapter 14. "MAP 0240: Memory Problem Resolution". 805-120 G D68 Description: Error log analysis indicates a machine check due to uncorrectable memory error. Action: Use Chapter 14. "MAP 0240: Memory Problem Resolution". 805-121 G D84 Description: Error log analysis indicates a machine check due to uncorrectable memory error. Action: Use Chapter 14. "MAP 0240: Memory Problem Resolution". 805-130 G D69 Description: Error log analysis indicates a machine check due to uncorrectable memory error. Action: Use Chapter 14. "MAP 0240: Memory Problem Resolution". 805-131 G D85 Description: Error log analysis indicates a machine check due to uncorrectable memory error. Action: Use Chapter 14. "MAP 0240: Memory Problem Resolution". 805-140 G D70 Description: Error log analysis indicates a machine check due to uncorrectable memory error. Action: Use Chapter 14. "MAP 0240: Memory Problem Resolution". 805-141 G D86 Description: Error log analysis indicates a machine check due to uncorrectable memory error. Action: Use Chapter 14. "MAP 0240: Memory Problem Resolution". 805-150 G E11 Description: Error log analysis indicates a machine check due to uncorrectable memory error. Action: Use Chapter 14. "MAP 0240: Memory Problem Resolution". 805-151 G E14 Description: Error log analysis indicates a machine check due to uncorrectable memory error. Action: Use Chapter 14. "MAP 0240: Memory Problem Resolution". 805-210 G D71 Description: Error log analysis indicates a machine check due to uncorrectable memory error. Action: Use Chapter 14. "MAP 0240: Memory Problem Resolution". 805-211 G D87 Description: Error log analysis indicates a machine check due to uncorrectable memory error. Action: Use Chapter 14. "MAP 0240: Memory Problem Resolution". 805-220 G D72 Description: Error log analysis indicates a machine check due to uncorrectable memory error. Action: Use Chapter 14. "MAP 0240: Memory Problem Resolution". 805-221 G D88 Description: Error log analysis indicates a machine check due to uncorrectable memory error. Action: Use Chapter 14. "MAP 0240: Memory Problem Resolution". 805-230 G D73 Description: Error log analysis indicates a machine check due to uncorrectable memory error. Action: Use Chapter 14. "MAP 0240: Memory Problem Resolution". 805-231 G D89 Description: Error log analysis indicates a machine check due to uncorrectable memory error. Action: Use Chapter 14. "MAP 0240: Memory Problem Resolution". 805-240 G D74 Description: Error log analysis indicates a machine check due to uncorrectable memory error. Action: Use Chapter 14. "MAP 0240: Memory Problem Resolution". 805-241 G D90 Description: Error log analysis indicates a machine check due to uncorrectable memory error. Action: Use Chapter 14. "MAP 0240: Memory Problem Resolution". 805-250 G E12 Description: Error log analysis indicates a machine check due to uncorrectable memory error. Action: Use Chapter 14. "MAP 0240: Memory Problem Resolution". 805-251 G E15 Description: Error log analysis indicates a machine check due to uncorrectable memory error. Action: Use Chapter 14. "MAP 0240: Memory Problem Resolution". 805-310 G D75 Description: Error log analysis indicates a machine check due to uncorrectable memory error. Action: Use Chapter 14. "MAP 0240: Memory Problem Resolution". 805-311 G D91 Description: Error log analysis indicates a machine check due to uncorrectable memory error. Action: Use Chapter 14. "MAP 0240: Memory Problem Resolution". 805-320 G D76 Description: Error log analysis indicates a machine check due to uncorrectable memory error. Action: Use Chapter 14. "MAP 0240: Memory Problem Resolution". 805-321 G D92 Description: Error log analysis indicates a machine check due to uncorrectable memory error. Action: Use Chapter 14. "MAP 0240: Memory Problem Resolution". 805-331 G D93 Description: Error log analysis indicates a machine check due to uncorrectable memory error. Action: Use Chapter 14. "MAP 0240: Memory Problem Resolution". 805-340 G D78 Description: Error log analysis indicates a machine check due to uncorrectable memory error. Action: Use Chapter 14. "MAP 0240: Memory Problem Resolution". 805-341 G D94 Description: Error log analysis indicates a machine check due to uncorrectable memory error. Action: Use Chapter 14. "MAP 0240: Memory Problem Resolution". 805-350 G E13 Description: Error log analysis indicates a machine check due to uncorrectable memory error. Action: Use Chapter 14. "MAP 0240: Memory Problem Resolution". 805-351 G E16 Description: Error log analysis indicates a machine check due to uncorrectable memory error. Action: Use Chapter 14. "MAP 0240: Memory Problem Resolution". 805-600 G Description: Error log analysis indicates a machine check due to uncorrectable memory error or unsupported memory. Action: Examine the memory modules and determine if they are supported types. If the modules are supported, then replace the appropriate memory module(s). Use Chapter 14. "MAP 0240: Memory Problem Resolution". 805-601 G 210 Description: Error log analysis indicates a machine check due to CPU internal cache error. 805-602 G 214 Description: Error log analysis indicates a machine check due to CPU address/data bus D01 parity error. 805-603 G 210 Description: Error log analysis indicates a machine check due to CPU bus transfer 214 error. D01 805-604 G 210 Description: Error log analysis indicates a machine check due to CPU address/data bus D01 parity error. 805-605 G 210 Description: Error log analysis indicates a machine check due to CPU bus transfer error. 805-606 G 214 Description: Error log analysis indicates a machine check due to memory controller internal error. 805-607 G 210 Description: Error log analysis indicates a machine check due to memory address 214 error. 805-608 G 214 Description: Error log analysis indicates a machine check due to a Flash ROM error. 217 805-609 G D01 Description: Error log analysis indicates a machine check due to a L2 parity error. 805-610 G Description: Error log analysis indicates a machine check due to ISA device error, but the device could not be identified. Action: Run diagnostics on the ISA devices. 805-611 G Description: Error log analysis indicates a machine check due to EISA/ISA bus time out error, but the device could not be identified. Action: Run diagnostics on the ISA devices. If multiple devices fail, use FFC 295. 805-612 G 214 Description: Error log analysis indicates a machine check due to an Illegal L2 copyback operation. 805-616 G software Description: Error log analysis indicates a machine check due to software. 805-617 G Description: Error log analysis indicates a machine check of unknown origin. Action: If the problem is persistent, use MAP 1540. 805-618 G Description: Error log analysis indicates multiple instances of machine check of unknown origin. Action: If the problem is persistent, use MAP 1540. 805-619 G 221 Description: Error log analysis indicates a machine check due to an unidentified source on the I/O subsystem. Action: Use Chapter 12. "MAP 0210: General Problem Resolution". 805-621 G 292 Description: Error log analysis indicates a machine check due to Integrated PCI device does not respond. 805-622 G 293 Description: Error log analysis indicates a machine check due to Integrated PCI device does not respond. 805-623 G 294 Description: Error log analysis indicates a machine check due to Integrated PCI device does not respond. 805-624 G 295 Description: Error log analysis indicates a machine check due to Integrated PCI device does not respond. 805-625 G 868 Description: Error log analysis indicates a machine check due to Integrated PCI device does not respond. 805-631 G 292 Description: Error log analysis indicates a machine check due to Internal error from PCI device. 805-632 G 293 Description: Error log analysis indicates a machine check due to Internal error from PCI device. 805-633 G 294 Description: Error log analysis indicates a machine check due to Internal error from PCI device. 805-634 G 295 Description: Error log analysis indicates a machine check due to Internal error from PCI device. 805-635 G 868 Description: Error log analysis indicates a machine check due to Internal error from PCI device. 805-640 G 2E8 Description: Error log analysis indicates a machine check due to a system bus error. 214 805-641 G 2E8 Description: Error log analysis indicates a machine check due to a processor bus 210 error. 805-642 G 2E8 Description: Error log analysis indicates a machine check due to a directory parity error. 805-643 G 2E8 Description: Error log analysis indicates a machine check due to a cache paradox. 805-644 G 2E8 Description: Error log analysis indicates a machine check due to an internal error. 805-645 G 2E8 Description: Error log analysis indicates a machine check due to a detected L2 hit signal. 805-646 G 2E8 Description: Error log analysis indicates a machine check due to an address/data bus 214 parity error. 805-649 G software Description: Error log analysis indicates a machine check due to a disabled I/O address space. Action: Run Standalone Diagnostics on all devices. Use any SRN reported. If no other SRN is reported, suspect a software problem. 805-801 G 166 Description: Slow fan or defective thermal sensor. 221 Action: 1) Check spacing around system enclosure, 2) check for obstructions to cooling air flow, 3) check that all fans can rotate freely, and spin with power applied. If reasons 1, 2 and 3 can be ruled out, then replace the listed FRUs. 805-802 G 152 Description: Over/Under voltage condition. 210 Action: Check AC line voltage per the Power MAP in your service guide. If the AC line voltage is correct replace the listed FRUs. 805-803 G 2E1 Description: System shutdown due to non-critical over temperature condition. 210 Action: 1) check for obstructions to cooling air flow, 2) check for accumulated dust on the CPU and planar. If reasons 1 and 2 can be ruled out, then replace the listed FRUs. 805-804 G 166 Description: System shutdown due to critical over temperature condition. 2E1 Action: Check to ensure fans are connected. If fans are connected, then replace the 152 listed FRUs. 805-805 G 152 Description: System shutdown due to loss of AC power. Action: Check the voltage range switch, if present, on the power supply and ensure that it is set to match the AC input voltage. If the range switch is set correctly or is not present refer to "MAP 1520: Power" in the Service Guide for your system. 805-807 G 166 Description: System shutdown due to an inoperative fan. Action: Check to ensure fans are connected. If fans are connected replace the listed FRU. 805-811 D 166 Description: Slow fan or defective thermal sensor. Action: 1. Check spacing around system enclosure 2. Check for obstructions to cooling air flow 3. Check that all fans rotate freely, and spin when power is applied. If reasons 1, 2, and 3 can be ruled out, then replace the listed FRUs. 805-812 D 152 Description: Over/Under voltage condition. 210 Action: Check the AC line voltage per the Power MAP in your service guide. If the AC line voltage is correct replace the listed FRUs. 805-813 D 2E1 Description: System shutdown due to non-critical over temperature condition. 210 Action: 1. Check for obstructions to cooling air flow. 2. Check for accumulated dust on the CPU and planar. If reasons 1 and 2 can be ruled out, then replace the listed FRUs. 806-001 D 806 GXT800P Graphics Adapter thru 806-017 806-018 D 806 GXT800P Graphics Adapter Monitor/Display Cable 806-100 D 806 Description: GXT800P Graphics Adapter 806-505 D 806 Description: GXT800P Graphics Adapter GXT800P Base Memory in slot 0, 1, 2, 3, or 298 4 806-515 D 806 Description: GXT800P Graphics Adapter GXT800P Base and Texture Memory in slot 0, 297 1, 2, 3, or 4 806-619 G 221 Description: Error log analysis indicates a machine check due to an unidentified source on the I/O subsystem. 806-700 D 298 GXT800P Base Memory in slot 0 806-701 D 298 GXT800P Base Memory in slot 1 806-702 D 298 GXT800P Base Memory in slot 2 806-703 D 298 GXT800P Base Memory in slot 3 806-704 D 298 GXT800P Base Memory in slot 4 806-710 D 297 GXT800P Base and Texture Memory in slot 0 806-711 D 297 GXT800P Base and Texture Memory in slot 1 806-712 D 297 GXT800P Base and Texture Memory in slot 2 806-713 D 297 GXT800P Base and Texture Memory in slot 3 806-714 D 297 GXT800P Base and Texture Memory in slot 4 806-e00 D 298 GXT800P Base Memory in slot 0 806-e01 D 298 GXT800P Base Memory in slot 1 806-e02 D 298 GXT800P Base Memory in slot 2 806-e03 D 298 GXT800P Base Memory in slot 3 806-e04 D 298 GXT800P Base Memory in slot 4 806-e10 D 297 GXT800P Base and Texture Memory in slot 0 806-e11 D 297 GXT800P Base and Texture Memory in slot 1 806-e12 D 297 GXT800P Base and Texture Memory in slot 2 806-e13 D 297 GXT800P Base and Texture Memory in slot 3 806-e14 D 297 GXT800P Base and Texture Memory in slot 4 807-201 D 199 Description: Device configuration error 891 807-202 D 199 Description: Enclosure failed to open 891 807-203 D 199 Description: Enclosure failed to return inquiry data 891 807-204 D 152 Description: Redundant power supply or fan failure 166 807-205 D 152 Description: Redundant power supply or fan failure 166 814-112 D 814 Description: The NVRAM test failed. 814-113 D 221 Description: The VPD test failed. 814-114 D 814 Description: I/O Card NVRAM test failed. 815-100 D 815 Description: The floating-point processor test failed. 815-101 D 815 Description: Floating point processor failed. 815-102 D 815 Description: Floating point processor failed. 815-200 D 815 Description: Floating point processor failed. 7C1 816-140 D 165 Description: The four-digit display test failed. 816 817-123 D 817 Description: The I/O planar time-of-day clock test failed. 817-124 D 817 Description: Time of day RAM test failed. 817-210 D 817 Description: The time-of-day clock is at POR. 817-211 D 817 Description: Time of day POR test failed. 169 817-212 D 151 Description: The battery is low. 816 817-213 D 817 Description: The real-time clock is not running. 817-215 D 817 Description: Time of day clock not running test failed. 817-217 D 817 Description: Time of day clock not running. 169 821-111 D 821 Description: Unexpected results from the test. B31 821-220 D B10 Description: Keyboard adapter fuse failed. 821 821-221 D 821 Description: The keyboard adapter test failed. 821-230 D 221 Description: Software error caused by hardware failure. 821-240 G 821 Description: The error log analysis indicates hardware failure. 821-241 G 221 Description: The error log analysis indicates hardware failure. 821-242 G 921 Description: The error log analysis indicates hardware failure. 821 821-243 G 922 Description: The error log analysis indicates hardware failure. 821 821-244 G 923 Description: The error log analysis indicates hardware failure. 821 821-310 D 821 Description: Standard Keyboard Adapter to failed. 821-331 821-332 D 821 Description: Cannot open device. software 821-333 D 821 Description: Keyboard/tablet adapter failed. to 821-334 821-921 D 921 Description: The keyboard adapter control logic failed. 821 821-922 D 922 Description: The keyboard adapter control logic failed. 821 821-923 D 923 Description: The keyboard adapter control logic failed. 821 823-111 D 823 Description: Standard Mouse adapter failed. to 925 823-112 823-113 D B10 Description: The mouse adapter fuse failed. 823 823-121 D 823 Description: Built-In mouse adapter problems. to 823-122 823-130 D 221 Description: Software error caused by hardware failure. 823-131 D 823 Description: Unable to put mouse adapter into nonblock mode. 925 823-132 D 823 Description: Built-In mouse adapter problem. to 823-133 823-134 D 823 Description: Cannot open device. software 823-140 G 823 Description: The error log analysis indicates hardware failure. 823-141 D 823 Description: Unable to place mouse adapter in block mode. 925 823-142 D 823 Description: Unable to place mouse adapter in block mode. 823-220 D B10 Description: The mouse adapter fuse failed. 823 824-220 Description: The tablet adapter fuse D B10 failed. 824 824-331 Description: An unexpected error occurred. D 824 227 824-332 Description: The enable/disable device D 824 test failed. 227 Note:Ensure that the wrap plug was not attached when the test was run. If the wrap plug was attached, remove it, and rerun the test. 824-333 Description: The internal wrap test D 824 failed. 824-334 Description: The tablet adapter fuse D B10 failed. 824 824-441 Description: An unexpected error occurred. D 824 824-442 Description: The wrap test failed. D 824 824-450 227 Description: Software error caused by D hardware failure. 824-461 227 Description: The error log analysis G indicates a hardware failure. 824-511 Description: An unexpected error occurred. D 824 824-512 Description: Tablet adapter reset test D 824 failed. 824-522 Description: Adapter fuse failure. D B10 824 824-523 Description: Device cannot be configured. D 824 824-524 Description: Cannot open device. D 824 software 826-111 D 221 Description: Cannot run the test because the device driver detected a hardware error. 826-112 D 221 Description: Unable to determine the type of adapter from the VPD. 826-113 D 826 Description: The VPD verification test failed. 826-114 D 826 Description: The register verification test failed. 826-121 D 221 Description: Cannot run the test because the device driver detected a hardware error. 826-122 D 221 Description: The data-wrap communications test failed. 826-123 D 221 Description: The modem control line test failed. 826-131 D 221 Description: Cannot run the test because the device driver detected a hardware error. 826-132 D 221 Description: The data wrap communications test failed. 826-133 D 221 Description: The modem control line test failed. 826-161 D 252 Description: Cannot run the test because the device driver detected a hardware error. 826-162 D 252 Description: The data wrap communications test failed. 826-163 D 252 Description: The modem control line test failed. 826-171 D 259 Description: Cannot run the test because the device driver detected a hardware error. 826-172 D 259 Description: The data wrap communications test failed. 826-173 D 259 Description: The modem control line test failed. 826-181 D 261 Description: Cannot run the test because the device driver detected a hardware error. 826-182 D 261 Description: The data wrap communications test failed. 826-183 D 261 Description: The modem control line test failed. 826-271 D 826 Description: Cannot run the test because the device driver detected a hardware 259 error. 826-272 D 826 Description: The data wrap communications test failed. 259 826-273 D 826 Description: The modem control line test failed. 259 826-281 D 826 Description: Cannot run the test because the device driver detected a hardware 259 error. 826-282 D 826 Description: The data wrap communications test failed. 259 826-283 D 826 Description: The modem control line test failed. 259 826-321 D 826 Description: Cannot run the test because the device driver detected a hardware error. 826-322 D 826 Description: The data wrap communications test failed. 826-323 D 826 Description: The modem control line test failed. 826-331 D 826 Description: Cannot run the test because the device driver detected a hardware error. 826-332 D 826 Description: The data wrap communications test failed. 826-333 D 826 Description: The modem control line test failed. 826-371 D 826 Description: Cannot run the test because the device driver detected a hardware error. 826-372 D 826 Description: The data wrap communications test failed. 826-373 D 826 Description: The modem control line test failed. 826-381 D 826 Description: Could not do the test because the device driver detected a hardware error. 826-382 D 826 Description: The data wrap communication test failed. 826-383 D 826 Description: The modem control line test failed. 826-481 D D56 Description: Could not do the test because the device driver detected a hardware error. 826-482 D D56 Description: The data wrap communication test failed. 826-483 D D56 Description: The modem control line test failed. 826-581 D 826 Description: Could not do the test because the device driver detected a hardware D56 error. 826-582 D 826 Description: The data wrap communication test failed. D56 826-583 D 826 Description: The modem control line test failed. D56 826-901 D software Description: An unexpected error occurred that can be attributed to software or to 826 hardware. 826-920 Action: Run diagnostics from a source other than from the disk or a network. If the same error occurs or if the original SRN was not obtained from disk or a network based diagnostics, use Chapter 12. "MAP 0210: General Problem Resolution" with a FFC of 826; otherwise, suspect a software problem. 826-921 D 826 Description: The adapter failed to configure software 826-922 D software Description: An unexpected error occurred that can be attributed to software or to 826 hardware. 826-924 Action: Run diagnostics from a source other than from the disk or a network. If the same error occurs or if the original SRN was not obtained from disk or a network based diagnostics, use Chapter 12. "MAP 0210: General Problem Resolution" with a FFC of 826; otherwise, suspect a software problem. 826-925 D 826 Description: The adapter failed to configure software 826-926 D software Description: An unexpected error occurred that can be attributed to software or to 826 hardware. 826-943 Action: Run diagnostics from a source other than from the disk or a network. If the same error occurs or if the original SRN was not obtained from disk or a network based diagnostics, use Chapter 12. "MAP 0210: General Problem Resolution" with a FFC of 826; otherwise, suspect a software problem. 827-112 D 221 Description: The parallel port data register write/read test failed. 827-121 D 827 Description: Cannot run the test because the device driver detected a hardware error. 827-122 D 827 Description: The parallel port data register write/read test failed. 827-123 D 827 Description: The parallel port control register write/read test failed. 827-124 D 827 Description: The parallel port data register read test failed. 827-125 D 827 Description: The parallel port control register read test failed. 827-126 D 827 Description: The parallel port control register read test failed. 827-131 D 827 Description: Cannot run the test because the device driver detected a hardware error. 827-132 D 827 Description: The control port register direction bit (write) test with BIDI enabled failed. 827-133 D 827 Description: The control port register direction bit (read) test with BIDI enabled failed. Service Failing Description and Action Request Function (Unless otherwise indicated use Chapter Number Codes 12. "MAP 0210: General Problem SRN Resolution".) Src. 827-141 D 827 Description: Cannot run the test because the device driver detected a hardware error. 827-142 D 827 Description: The parallel port control register write/read test with BIDI enabled failed. 827-151 D 221 Description: Cannot run the test because the device driver detected a hardware error. 827-152 D 827 Description: The parallel port status register read test failed. 827-161 D 827 Description: Cannot run the test because the device driver detected a hardware error. 827-162 D 221 Description: The parallel port interrupt test failed. 827-163 D 221 Description: The parallel port interrupt test failed. 827-201 D 827 Description: The extend control register of the parallel port failed a read/write test. 827-202 D 827 Description: Input/output to the FIFO (without interrupts) failed. 827-203 D 827 Description: Input/output to the FIFO (with interrupts) failed. 827-204 D 827 Description: Direct memory access to the FIFO failed. 828-501 D 828 Description: The diskette adapter test failed. 82C-102 D 82C Description: Adapter test failed. 82C-104 D 82C Description: Display test failed. 725 830-111 D 830 Description: Could not do the test because the device driver detected a 227 hardware error. 830-114 D 830 Description: The register verification test failed. 830-121 D 830 Description: Could not do the test because the device driver detected a 227 hardware problem. 830-122 D 830 Description: The data wrap communication test failed. 227 830-123 D 830 Description: The modem control line test failed. 227 830-124 D 830 Description: The memory test failed. 830-151 D B54 Description: Could not do the test because the device driver detected a 830 hardware error. 830-152 D B54 Description: The data wrap communication test failed. 830 830-153 D D54 Description: The modem control line test failed. 830 830-171 D 259 Description: Could not run the test because the device driver detected a hardware error. 830-172 D 259 The data wrap communication test failed. 830-173 D 259 Description: The modem control line test failed. 830-181 D 261 Description: Could not do the test because the device driver detected a hardware error. 830-182 D 261 Description: The data wrap communication test failed. 830-183 D 261 Description: Interposer Wrap test failed. 830-251 D 830 Description: Could not perform because the device driver detected a hardware D57 error. 830-252 D 830 Description: The data wrap communication test failed. B54 830-253 D 830 Description: The modem control line test failed. B54 830-271 D 830 Description: Could not perform because the device driver detected a hardware B54 error. 830-272 D 830 Description: The data wrap communication test failed. B54 830-273 D 830 Description: The modem control line test failed B54 830-281 D 830 Could not perform the test because the device driver detected a hardware error. D57 830-282 D 830 Description: The data wrap communication test failed. B54 830-283 D 830 Description: The modem control line test failed. B54 830-481 D B54 Description: Could not do the test because the device driver detected a hardware error. 830-482 D B54 Description: The data wrap communication test failed. 830-483 D B54 Description: Async Cable Wrap Test failed. 830-901 D software Description: An unexpected error occurred that can be attributed to to 830 software or hardware. 830-920 Action: Run diagnostics from a source other than from the disk or a network. If the same error occurs or if the original SRN was not obtained from disk or a network based diagnostics, use Chapter 12. "MAP 0210: General Problem Resolution" with a FFC of 830; otherwise, suspect a software problem. 830-921 D 830 Description: The adapter failed to configure software 830-922 D software Description: An unexpected error occurred that can be attributed to to 830 software or hardware. 830-924 Action: Run diagnostics from a source other than from the disk or a network. If the same error occurs or if the original SRN was not obtained from disk or a network based diagnostics, use Chapter 12. "MAP 0210: General Problem Resolution" with a FFC of 830; otherwise, suspect a software problem. 830-925 D 830 Description: The adapter failed to configure software 830-926 D software Description: An unexpected error occurred that can be attributed to to 830 software or hardware. 830-943 Action: Run diagnostics from a source other than from the disk or a network. If the same error occurs or if the original SRN was not obtained from disk or a network based diagnostics, use Chapter 12. "MAP 0210: General Problem Resolution" with a FFC of 830; otherwise, suspect a software problem. 831-111 D 221 Description: Cannot run the test because the device driver detected a hardware error. 831-112 D 221 Description: Unable to determine the type of adapter from the VPD. 831-113 D 831 Description: The VPD verification test failed. 831-114 D 831 Description: The register verification test failed. 831-121 D 221 Description: Cannot run the test because the device driver detected a hardware error. 831-122 D 221 Description: The data wrap communications test failed. 831-123 D 221 Description: The modem control line test failed. 831-131 D 221 Description: Cannot run the test because the device driver detected a hardware error. 831-132 D 221 Description: The data wrap communications test failed. 831-133 D 221 Description: The modem control line test failed. 831-161 D 252 Description: Cannot run the test because the device driver detected a hardware error. 831-162 D 252 Description: The data wrap communications test failed. 831-163 D 252 Description: The modem control line test failed. 831-164 D 221 Description: Cannot run the test because the device driver detected a hardware 252 error. 831-165 D 221 Description: The data wrap communications test failed. 252 831-166 D 221 Description: The modem control line test failed. 252 831-171 D 259 Description: Cannot run the test because the device driver detected a hardware error. 831-172 D 259 Description: The data wrap communications test failed. 831-173 D 259 Description: The modem control line test failed. 831-181 D 261 Description: Cannot run the test because the device driver detected a hardware error. 831-182 D 261 Description: The data wrap communications test failed. 831-183 D 261 Description: The modem control line test failed. 831-271 D 831 Description: Cannot run the test because the device driver detected a hardware 259 error. 831-272 D 831 Description: The data wrap communication test failed. 259 831-273 D 831 Description: The modem control line test failed. 259 831-281 D 831 Description: Cannot run the test because the device driver detected a hardware 259 error. 831-282 D 831 Description: The data wrap communications test failed. 259 831-283 D 831 Description: The modem control line test failed. 259 831-321 D 831 Description: Cannot run the test because the device driver detected a hardware error. 831-322 D 831 Description: The data wrap communications test failed. 831-323 D 831 Description: The modem control line test failed. 831-331 D 831 Description: Cannot run the test because the device driver detected a hardware error. 831-332 D 831 Description: The data wrap communications test failed. 831-333 D 831 Description: The modem control line test failed. 831-371 D 831 Description: Cannot run the test because the device driver detected a hardware error. 831-372 D 831 Description: The data wrap communications test failed. 831-373 D 831 Description: The modem control line test failed. 831-381 D 831 Description: Cannot run the test because the device driver detected a hardware error. 831-382 D 831 Description: The data wrap communications test failed. 831-383 D 831 Description: The modem control line test failed. 831-481 D D56 Description: Could not do the test because the device driver detected a hardware error. 831-482 D D56 Description: The data wrap communication test failed. 831-483 D D56 Description: The modem control line test failed. 831-581 D 831 Description: Could not do the test because the device driver detected a D56 hardware error. 831-582 D 831 Description: The data wrap communication test failed. D56 831-583 D 831 Description: The modem control line test failed. D56 831-901 D software Description: An unexpected error occurred that can be attributed to to 831 software or hardware. 831-920 Action: Run diagnostics from a source other than from the disk or a network. If the same error occurs or if the original SRN was not obtained from disk or a network based diagnostics, use Chapter 12. "MAP 0210: General Problem Resolution" with a FFC of 831; otherwise, suspect a software problem. 831-921 D 831 Description: The adapter failed to configure software 831-922 D software Description: An unexpected error occurred that can be attributed to to 831 software or hardware. 831-924 Action: Run diagnostics from a source other than from the disk or a network. If the same error occurs or if the original SRN was not obtained from disk or a network based diagnostics, use Chapter 12. "MAP 0210: General Problem Resolution" with a FFC of 831; otherwise, suspect a software problem. 831-925 D 831 Description: The adapter failed to configure software 831-926 D software Description: An unexpected error occurred that can be attributed to to 831 software or hardware. 831-943 Action: Run diagnostics from a source other than from the disk or a network. If the same error occurs or if the original SRN was not obtained from disk or a network based diagnostics, use Chapter 12. "MAP 0210: General Problem Resolution" with a FFC of 831; otherwise, suspect a software problem. 832-xxx G xxx I/O Device Internal Error Note: xxx represents the last 3 digits of the SRN. 833-xxx G xxx Description: PCI device address parity error, PCI device data parity error, or 296 PCI device abort error. The diagnostics screen indicates the actual error. 2C9 Note: xxx represents the last 3 digits of the SRN. 836-101 Description: Cannot run the test D 836 because the device driver detected a hardware error. 836-111 Description: Cannot run test because D 836 the device driver detected a hardware 227 error. 836-112 Description: Unable to determine the D 836 type of adapter from the VPD. 227 836-113 Description: The VPD verification test D 836 failed. 836-114 Description: The register verification D 836 test failed. 836-115 Description: The VPD verification test D 836 failed. 836-116 Description: The 128-port controller D B54 line test failed. 836 836-117 D 684 Description: Remote Async Node test failed. 836-118 Description: Remote async node test D 837 failed. 836-119 Description: Sync line termination test F 836 failed. 836-151 Description: Cannot run the test D 837 because the device driver detected a hardware error. 836-152 Description: The data wrap D 837 communications test failed. 836-153 Description: The modem control line D 837 test failed. 836-154 D 684 Desciption: Cannot run the test because the device driver detected a hardware 836 error. 836-155 D 684 Description: The data wrap communications test failed. 836 152 836-161 Description: Cannot run the test D C22 because the device driver detected a hardware error. 836-162 Description: The data wrap D C22 communications test failed. 836-163 Description: The modem control line D C22 test failed. 836-164 Description: The data wrap D D06 communication test failed. 836-171 Description: Cannot run the test D 259 because the device driver detected a hardware error. 836-172 Description: The data wrap D 259 communications test failed. 836-173 Description: The modem control line D 259 test failed. 836-174 D 263 Description: Cannot run the test because the device driver detected a hardware error while running the Printer/Terminal cable wrap test. 836-175 D 263 Description: The data wrap communications test failed while running the Printer/Terminal cable wrap test. 836-181 Description: Cannot run the test D 261 because the device driver detected a hardware error. 836-182 Description: The data wrap D 261 communications test failed. 836-183 Description: The modem control line D 261 test failed. 836-251 Description: Cannot run the test D 836 because the device driver detected a 837 hardware error. 836-252 Description: The data wrap D 836 communications test failed. 837 836-253 Description: The modem control line D 836 test failed. 837 836-254 D 836 Description: Cannot run the test because the device driver detected a hardware 684 error while running the Remote Async Node wrap test. 836-255 D 836 Description: The data wrap communications test failed while running 684 the Remote Async Node wrap test. 836-271 Description: Cannot run the test D 836 because the device driver detected a 837 hardware error. 836-272 Description: The data wrap D 836 communications test failed. 837 836-273 Description: The modem control line D 836 test failed. 837 836-274 D 836 Description: Cannot run the test because the device driver detected a hardware 684 error while running the Printer/Terminal cable wrap test. 836-275 D 836 Description: The data wrap communications test failed while running 684 the Printer/Terminal cable wrap test. 836-281 Description: Cannot run the test D 836 because the device driver detected a 837 hardware error. 836-282 Description: The data wrap D 836 communication test failed. 837 836-283 Description: The modem control line D 836 test failed. 837 836-481 Description: Could not do the test D D56 because the device driver detected a hardware error. 836-482 Description: The data wrap D D56 communication test failed. 836-483 Description: The modem control line D D56 test failed. 836-901 D software Description: An unexpected error occurred that can be attributed to to 836 software or hardware. 836-920 Action: Run diagnostics from a source other than from the disk or a network. If the same error occurs or if the original SRN was not obtained from disk or a network based diagnostics, use Chapter 12. "MAP 0210: General Problem Resolution" with a FFC of 836; otherwise, suspect a software problem. 836-921 D 836 Description: The adapter failed to configure software 836-922 D software Description: An unexpected error occurred that can be attributed to to 836 software or hardware. 836-924 Action: Run diagnostics from a source other than from the disk or a network. If the same error occurs or if the original SRN was not obtained from disk or a network based diagnostics, use Chapter 12. "MAP 0210: General Problem Resolution" with a FFC of 836; otherwise, suspect a software problem. 836-925 D 836 Description: The adapter failed to configure software 836-926 D software Description: An unexpected error occurred that can be attributed to to 836 software or hardware. 836-943 Action: Run diagnostics from a source other than from the disk or a network. If the same error occurs or if the original SRN was not obtained from disk or a network based diagnostics, use Chapter 12. "MAP 0210: General Problem Resolution" with a FFC of 836; otherwise, suspect a software problem. 840-212 D 840 Description: FIFO empty bit set. Action: Go to Chapter 7. "MAP 0050: SCSI 221 Problems Isolation Procedure". 840-213 D 840 Description: FIFO empty bit clear. Action: Go to Chapter 7. "MAP 0050: SCSI 221 Problems Isolation Procedure". 840-214 D 840 Description: FIFO full bit set. Action: Go to Chapter 7. "MAP 0050: SCSI 221 Problems Isolation Procedure". 840-215 D 840 Description: FIFO full bit clear. Action: Go to Chapter 7. "MAP 0050: SCSI 221 Problems Isolation Procedure". 840-216 D 840 Description: FIFO data miscompare. Action: Go to Chapter 7. "MAP 0050: SCSI 221 Problems Isolation Procedure". 840-217 D 840 Description: SCSI FIFO data miscompare. Action: Go to Chapter 7. "MAP 0050: SCSI 221 Problems Isolation Procedure". 840-218 D 840 Description: SCSI FIFO underflow. Action: Go to Chapter 7. "MAP 0050: SCSI 221 Problems Isolation Procedure". 840-219 D 840 Description: SCSI parity error. Action: Go to Chapter 7. "MAP 0050: SCSI 221 Problems Isolation Procedure". 840-220 D 840 Description: SCSI FIFO flags error. Action: Go to Chapter 7. "MAP 0050: SCSI 221 Problems Isolation Procedure". 840-221 D 840 Description: Miscompare during the write/read of the configuration register. 221 Action: Go to Chapter 7. "MAP 0050: SCSI Problems Isolation Procedure". 840-222 D 840 Description: Error during the write/read of the memory register. 221 Action: Go to Chapter 7. "MAP 0050: SCSI Problems Isolation Procedure". 840-223 D 840 Description: Miscompare during the write/read of the memory I/O register. 221 Action: Go to Chapter 7. "MAP 0050: SCSI Problems Isolation Procedure". 840-224 D 840 Description: Error reading the PCI configuration register. 221 840-225 D 840 Description: Adapter POST failed. 221 840-230 D D50 Description: Arbitration test failed. Action: Go to Chapter 7. "MAP 0050: SCSI 840 Problems Isolation Procedure".. 840-231 D D50 Description: Function could not complete. 840 Action: Go to Chapter 7. "MAP 0050: SCSI Problems Isolation Procedure". 840-232 D D50 Description: SCSI bus data miscompare. Action: Go to Chapter 7. "MAP 0050: SCSI 840 Problems Isolation Procedure". 840-240 D 840 Description: No terminal power. Action: Go to Chapter 7. "MAP 0050: SCSI 221 Problems Isolation Procedure". 840-301 D 840 Description: Configuration open failed for parent bus. D50 software 840-700 G 840 Description: Error log analysis indicates a PCI SCSI adapter failure. software 840-701 G 840 Description: Error log analysis indicates a PCI SCSI adapter failure. software 840-702 G 840 Description: Error log analysis indicates a PCI SCSI adapter failure. software 840-703 G 840 Description: Error log analysis indicates a PCI SCSI adapter failure. software 840-704 G 840 Description: Error log analysis indicates a PCI SCSI adapter failure. software 840-705 G 840 Description: Error log analysis indicates a PCI SCSI adapter failure. software 840-800 G 746 Description: Error log analysis indicates a PCI SCSI adapter PTC failure. Action: Go to Chapter 7. "MAP 0050: SCSI Problems Isolation Procedure". 840-802 G 840 Description: Error log analysis indicates a PCI SCSI bus failure. Action: Go to Chapter 7. "MAP 0050: SCSI Problems Isolation Procedure". 844-XXX D 844 Description: A 7135 controller problem series is indicated. Action: Use 7135 documentation. 845-XXX D 845 Description: A 7135 DASD drawer problem is indicated. series Action: Use 7135 documentation. 846-XXX D 846 Description: A 7135 DASD drawer problem is indicated. series Action: Use 7135 documentation. 868-110 D 221 Description: The adapter diagnostic subcommand test failed. 868-130 D 279 Description: The adapter fuse test failed. 868-140 D 868 Description: The wrap test failed. 868-150 D 868 Description: The BCR registers write/read test failed. 868-160 D 868 Description: The POS registers write/read test failed. 868-170 D 868 Description: The internal/external reset test failed. 868-180 D 279 Description: The adapter command timed out. 868 Note: Check the fuse before replacing. 868-190 D 221 Description: A software error was caused by a hardware failure. 868-191 G 868 Description: Analysis of the error log indicates a problem with the hardware. 868-192 G 221 Description: Analysis of the error log indicates a problem with the hardware. 868-193 G 279 Description: Analysis of the error log indicates a problem with the hardware. 868-194 G 868 Description: Analysis of the error log indicates a problem with the hardware. 868-200 D 868 Description: ROM CRC error. 868-201 D 868 Description: Adapter RAM error. 868-202 D 868 Description: The control logic failed. 868-203 D 868 Description: The control logic failed. 868-204 D 868 Description: The control logic failed. 868-205 D 868 Description: The control logic failed. 868-206 D 868 Description: Diagnostics completed with a previous error. 868-211 D 279 Description: The device failed to configure. 868 software 868-212 D 221 Description: FIFO empty bit set. Action: Go to Chapter 7. "MAP 0050: SCSI Problems Isolation Procedure". 868-213 D 221 Description: FIFO empty bit clear. Action: Go to Chapter 7. "MAP 0050: SCSI Problems Isolation Procedure". 868-214 D 221 Description: FIFO full bit set. Action: Go to Chapter 7. "MAP 0050: SCSI Problems Isolation Procedure". 868-215 D 221 Description: FIFO full bit clear. Action: Go to Chapter 7. "MAP 0050: SCSI Problems Isolation Procedure". 868-216 D 221 Description: FIFO data miscompare. Action: Go to Chapter 7. "MAP 0050: SCSI Problems Isolation Procedure". 868-217 D 221 Description: SCSI FIFO data miscompare. Action: Go to Chapter 7. "MAP 0050: SCSI Problems Isolation Procedure". 868-218 D 221 Description: SCSI FIFO underflow. Action: Go to Chapter 7. "MAP 0050: SCSI Problems Isolation Procedure". 868-219 D 221 Description: SCSI parity error. Action: Go to Chapter 7. "MAP 0050: SCSI Problems Isolation Procedure". 868-220 D 221 Description: SCSI FIFO flags error. Action: Go to Chapter 7. "MAP 0050: SCSI Problems Isolation Procedure". 868-221 D 221 Description: Miscompare during the write/read of the configuration register. Action: Go to Chapter 7. "MAP 0050: SCSI Problems Isolation Procedure". 868-222 D 221 Description: Error during the write/read of the memory register. Action: Go to Chapter 7. "MAP 0050: SCSI Problems Isolation Procedure". 868-223 D 221 Description: Miscompare during the write/read of the memory I/O register. Action: Go to Chapter 7. "MAP 0050: SCSI Problems Isolation Procedure". 868-224 D 221 Description: Error reading the PCI configuration register. Action: Use Chapter 12. "MAP 0210: General Problem Resolution". 868-225 D 221 Description: POST failed. 868-230 D D50 Description: Arbitration test failed. Action: Go to Chapter 7. "MAP 0050: SCSI 868 Problems Isolation Procedure". 868-231 D D50 Description: Function could not complete. 868 Action: Go to Chapter 7. "MAP 0050: SCSI Problems Isolation Procedure". 868-232 D D50 Description: SCSI bus data miscompare. Action: Go to Chapter 7. "MAP 0050: SCSI 868 Problems Isolation Procedure". 868-240 D 221 Description: No terminal power. Action: Go to Chapter 7. "MAP 0050: SCSI Problems Isolation Procedure". 868-301 D 868 Description: Configuration open failed for parent bus. D50 software 868-700 G 868 Description: Error log analysis indicates a PCI SCSI adapter failure. software 868-701 G 868 Description: Error log analysis indicates a PCI SCSI adapter failure. software 868-702 G 868 Description: Error log analysis indicates a PCI SCSI adapter failure. software 868-703 G 868 Description: Error log analysis indicates a PCI SCSI adapter failure. software 868-704 G 868 Description: Error log analysis indicates a PCI SCSI adapter failure. software 868-705 G 868 Description: Error log analysis indicates a PCI SCSI adapter failure. software 868-800 G 868 Description: Error log analysis indicates a PCI SCSI adapter PTC failure. Action: Go to Chapter 7. "MAP 0050: SCSI Problems Isolation Procedure". 868-802 G 868 Description: Error log analysis indicates a PCI SCSI bus failure. Action: Go to Chapter 7. "MAP 0050: SCSI Problems Isolation Procedure". 887-101 D 887 Description: POS register test failed. 887-102 D 887 Description: I/O register test failed. 887-103 D 887 Description: Local RAM test failed. 887-104 D 887 Description: Vital Product Data (VPD) failed. 887-105 D 887 Description: LAN coprocessor internal tests failed. 887-106 D 887 Description: Internal loopback test failed. 887-107 D 887 Description: External loopback test failed. 887-108 D 887 Description: External loopback test failed. 887-109 D 887 Description: External loopback parity tests failed. 887-110 D 887 Description: External loopback fairness test failed. 887-111 D 887 Description: External loopback fairness and parity tests failed. 887-112 D 887 Description: External loopback (twisted pair) test failed. 887-113 D 887 Description: External loopback (twisted pair) parity test failed. 887-114 D 887 Description: Ethernet loopback (twisted pair) fairness test failed. 887-115 D 887 Description: External loopback (twisted pair) fairness and parity tests failed. 887-116 D 887 Description: Twisted pair wrap data failed ). 887-117 D 887 Description: Device configuration fails. software 887-118 D 887 Description: Device driver indicates a hardware problem. 887-120 D 887 Description: Device driver indicates a hardware problem. 887-121 D B08 Description: Ethernet transceiver test failed. 887-122 B09 Description: Ethernet 10 Base-2 transceiver test failed. 887-123 D 887 Description: Internal loopback test failed. 887-124 G 887 Description: Error log indicates a hardware problem. software 887-125 G 887 Description: Fuse test failed. 887-202 D 887 Description: Vital product data test failed. 887-203 D 887 Description: Vital product data test failed. 887-209 D 887 Description: RJ-45 converter test failed. 887-304 D 887 Description: Coprocessor internal test failed. 887-305 D 887 Description: Internal loopback test failed. 887-306 D 887 Description: Internal loopback test failed. 887-307 D 887 Description: External loopback test failed. 887-319 D 887 Description: Device driver indicates a hardware failure. software 887-400 D 887 Description: Fuse test failed. 887-401 D 887 Description: Circuit breaker for Ethernet test failed. 887-402 D B09 Description: Ethernet 10 Base-2 transceiver test failed. 887 887-403 D B08 Description: Ethernet 10 Base-T transceiver test failed. 887 887-404 D C29 Description: RJ-45 converter test failed. 887 887-405 F Ethernet Description: Rerun diagnostics in advanced mode for accurate problem network determination. 887 89c-111 D 89c Description: Unable to reserve device. B88 89c-112 D 89c Description: Unable to do configuration. B88 89c-113 D 89c Description: Unable to open the device driver. B88 89c-121 D 89c Description: The CD-ROM drive indicates an error. 89c-122 D 89c Description: The CD-ROM drive indicates an error. 89c-123 D 89c Description: The CD-ROM drive indicates an error. 89c-125 D 89c Description: The CD-ROM drive indicates an error. B88 89c-126 D 89c Description: The CD-ROM drive indicates an error. 89c-127 D 89c Description: The CD-ROM drive indicates an error. 89c-128 D 89c Description: The CD-ROM drive indicates an error. 89c-129 D 89c Description: The CD-ROM drive indicates an error. 89c-150 D Media Description: A media error was detected. 89c 89c-151 D 89c Description: A command timeout was detected. D88 89c-152 D 89c Description: A command reservation conflict was detected. 89c-162 D 89c Description: The CD-ROM drive indicates an error. 89c-171 D 89c Description: Unable to reserve device. 89c-172 D 89c Description: Unable to do configuration. 89c-173 D 89c Description: Unable to open device driver. 89c-175 D 89c Description: The CD-ROM drive indicates an error. 89c-198 D 89c Description: Undefined error detected. B88 89c-199 D 89c Description: Undefined error detected. 89c-211 D 89c Description: The LED test failed. 89c-281 D 89c Description: No tone during audio test. 89c-301 G 89c Description: Errors found during ELA. 89c-302 G 89c Description: Errors found during ELA. B88 900-001 D 900 Description: "NO" to color panel 227 Monitor 900-002 D 900 Description: "NO" to cursor panel Monitor 900-007 D Info code Description: The EMC_SCROLLING_17_H_TEST failed 900-009 D Info code Description: The EMC_SCROLLING_21_H_TEST failed 900-064 D 900 Description: TRIO64V+_TIMEOUT 227 900-101 D 900 Description: Color miscompare 227 900-102 D 900 Description: Clipping error 227 900-103 D 900 Description: Rectangle fill test failed 227 900-128 D software Description: MALLOC_ERROR 900 900-161 D software Description: Loop count value in rules file is zero 900-191 D 900 Description: Red screen error 227 900-193 D 900 Description: Green screen error 227 900-1FF D 900 Description: Rectangle fill test failed 227 900-201 D 900 Description: Color miscompare 227 900-202 D 900 Description: Clipping error 227 900-203 D 900 Description: Image transfer across Plane Test failed 227 900-211 D software Description: INTERNAL_ERROR_DATA_SIZE 900-212 D software Description: INTERNAL_ERROR_NO_ACCESS 900-215 D 900 Description: Black screen error 227 900-217 D 900 Description: 9 x 7 Cross hatch grid failed. 227 900-233 D software Description: OPEN_RCM_ERROR 900-234 D software Description: IOCTL_GSC_HANDLE_FAILED 900-235 D software Description: AIXGSC_MAKE_GP_FAILED 900-236 D software Description: AIXGSC_UNMAKE_GP_FAILED 900-237 D software Description: DEVICE_BUSY_ERROR 900-241 D Info code Description: The SCROLLING_17_H_TEST failed. 900-263 D Info code Description: The EMC_SCROLLING_21_H_TEST failed 900-2FF D 900 Description: Image transfer across Plane Test failed 227 900-301 D 900 Description: A write of "0x00" to the palette register failed 227 900-302 D 900 Description: A write of "0x15" to the palette register failed 227 900-303 D 900 Description: A write of "0x2A" to the palette register failed 227 900-304 D 900 Description: A write of "0x3F" to the palette register failed 227 900-305 D 900 Description: The test of the palette registers failed 227 900-3FF D 900 Description: The test of the palette registers failed 227 900-401 D 900 Description: Frame buffer base address inconsistent 227 900-402 D 900 Description: VRAM inaccessible 227 900-403 D 900 Description: Miscompare found in VRAM 227 900-404 D 900 Description: The test of the VRAM failed 227 900-447 D 900 Description: Green screen error 227 900-449 D 900 Description: Blue Screen error 227 900-471 D 900 Description: 9 x 7 Cross hatch grid failed. 227 900-473 D 900 Description: 11 x 9 Cross hatch grid failed. 227 900-495 D Info code Description: The SCROLLING_17_H_TEST failed. 900-497 D Info code Description: The SCROLLING_21_H_TEST failed. 900-4FF D 900 Description: The test of the VRAM failed 227 900-501 D 900 Description: Color miscompare 227 900-502 D 900 Description: Clipping error 227 900-503 D 900 Description: Direct Frame Buffer test failed 227 900-5FF D 900 Description: Direct Frame Buffer test failed 227 900-601 D 900 Description: Video Stream Register test failed 227 900-602 D 900 Description: Video Stream hardware test failed 227 900-6FF D 900 Description: Video Stream hardware test failed 227 900-701 D 900 Description: 0 Degree Short Stroke Draw failed 227 900-702 D 900 Description: 45 Degree Short Stroke Draw failed 227 900-703 D 900 Description: Blue Screen error, or 90 Degree Short Stroke Draw failed 227 900-704 D 900 Description: 135 Degree Short Stroke Draw failed 227 900-705 D 900 Description: White screen error, or 180 Degree Short Stroke Draw failed 227 900-706 D 900 Description: 225 Degree Short Stroke Draw failed 227 900-707 D 900 Description: 270 Degree Short Stroke Draw failed 227 900-708 D 900 Description: 315 Degree Short Stroke Draw failed 227 900-709 D 900 Description: Short Stroke Vector Function test failed 227 900-727 D 900 Description: 11 x 9 Cross hatch grid failed. 227 900-750 D Info code Description: The SCROLLING_21_H_TEST failed. 900-753 D Info code Description: The EMC_SCROLLING_17_H_TEST failed 900-7FE D 900 Description: Short Stroke Vector Function test failed 227 900-7FF D software Description: Bad vector detected 900 227 900-801 D 900 Description: Color for PatBlt thru screen failed 227 900-802 D 900 Description: Clipping for PatBlt thru screen failed 227 900-803 D 900 Description: Color for PatBlt Across screen failed 227 900-804 D 900 Description: Clipping for PatBlt Across screen failed 227 900-805 D 900 Description: Pattern Fill Across the Plane test failed 227 900-8FF D 900 Description: Pattern Fill Across the Plane test failed 227 900-901 D 900 Description: Color miscompare of white boxes detected 227 900-902 D 900 Description: Clipping error of white boxes detected 227 900-903 D 900 Description: Color miscompare of color bars detected 227 900-904 D 900 Description: Clipping error of white boxes detected 227 900-905 D 900 Description: Color miscompare of white boxes detected 227 900-906 D 900 Description: Clipping error of white boxes detected 227 900-907 D 900 Description: Color miscompare of white boxes detected 227 900-908 D 900 Description: Clipping miscompare of white boxes detected 227 900-909 D 900 Description: The Area fill test (color bars) failed 227 900-9FF D 900 Description: The Area fill test (color bars) failed 227 900-937 D 900 Description: Red screen error 227 900-959 D 900 Description: White screen error 227 900-961 D 900 Description: Black screen error 227 900-A01 D 900 Description: Color miscompare of horizontal top line 227 900-A02 D 900 Description: Clipping error of horizontal top line 227 900-A03 D 900 Description: Color miscompare of vertical right line 227 900-A04 D 900 Description: Clipping error of vertical right line 227 900-A05 D 900 Description: Color miscompare of horizontal bottom line 227 900-A06 D 900 Description: Clipping error of horizontal bottom line 227 900-A07 D 900 Description: Color miscompare of vertical left line 227 900-A08 D 900 Description: Clipping error of vertical left line 227 900-A09 D 900 Description: Color miscompare of horizontal center line 227 900-A0A D 900 Description: Clipping error of horizontal center line 227 900-A0B D 900 Description: Color miscompare of vertical center line 227 900-A0C D 900 Description: Clipping error of vertical center line 227 900-A0D D 900 Description: Reserved 227 900-A0F D 900 Description: Reserved 227 900-A10 D 900 Description: Color miscompare of textured top line 227 900-A11 D 900 Description: Clipping error of textured top line 227 900-A12 D 900 Description: Line Drawing Function test failed 227 900-AFF D 900 Description: Line Drawing Function test failed 227 900-B01 D 900 Description: Rectangle Area Color miscompare detected 227 900-B02 D 900 Description: Rectangle Area Clip error detected 227 900-B03 D 900 Description: Clipped Area Horizontal color miscompare (background line color 227 wrong) 900-B04 D 900 Description: Clipped Area Horizontal clip miscompare (clip of background line 227 wrong) 900-B05 D 900 Description: Clipped Area Vertical color miscompare (background line color wrong) 227 900-B06 D 900 Description: Clipped Area Vertical clip error (clip of background line wrong) 227 900-B07 D 900 Description: The clipping function test failed. 227 900-BFF D 900 Description: The clipping function test failed. 227 900-C01 D 900 Description: The BIOS read failed. 227 900-C02 D 900 Description: The BIOS function test failed. 227 900-CFF D 900 Description: The BIOS function test failed. 227 900-D01 D 900 Description: The HW cursor function test failed. 227 900-DFF D 900 Description: The HW cursor function test failed. 227 901-xxx Description: Vendor SCSI device problem. Refer to the service documentation for this device. 902-xxx Description: Vendor display problem. Refer to the service documentation for this display. 903-xxx Description: Vendor Async device problem. Refer to the service documentation for this device. 904-xxx Description: Vendor Parallel device problem. Refer to the service documentation for this device. 905-xxx Description: Vendor device problem. Refer to the service documentation for this device. 908-001 D 908 Description: Invalid function request or to C33 bad parameters passed. 908-010 C48 908-016 D 908 Description: MCIC failed reading header. to 908-019 908-020 D C33 Description: Error closing 7250 DD. 908 C36 908-111 D 908 Description: Loader check sum error. C33 C36 908-112 D C33 Description: DMA failed to complete a 908 transfer. C36 C34 908-113 D 908 Description: Errors in loading ASCII C33 registers. C36 908-114 D C33 Description: Errors in loading ASCII to 908 registers. 908-118 C36 908-120 D 908 Description: DMA transfer or PFCA data to C33 error. 908-150 C36 908-151 D 908 Description: SPAN board error. to 908-158 908-160 D 908 Description: 7250 is not available. C33 System C36 908-200 D C33 Description: GPSS board failure. to 908 908-254 C36 908-255 D C33 Description: CP NMI bus timeout C34 interrupt error. 908 C48 908-256 D C33 Description: GPSS board failure. to 908 908-454 C36 908-455 D C33 Description: CP NMI bus timeout 908 interrupt error. C34 C48 908-456 D C33 Description: GPSS board failure. to 908 908-699 C36 908-700 D C34 Description: BLT or RATTLER error. to C33 908-766 C48 908-767 D C35 Description: VOO feature error. to C34 908-769 C44 908-770 D C34 Description: RSS BIST failure. to C33 908-799 C48 908-800 D C46 Description: Base 16M CHAP0 SIMM bad. D66 908-801 D C45 Description: RSS base 12M CHAP0 SIMM bad (801). D66 908-802 D C46 Description: RSS AG 16M CHAP0 SIMM bad (802). D66 908-803 D C45 Description: RSS AG 12M CHAP0 SIMM bad (803). D66 908-804 D C47 Description: RSS TX 16M CHAP0 SIMM bad (804). D66 908-805 D C46 Description: Base 16M CHAP 1 SIMM bad (805). D66 908-806 D C45 Description: RSS base 12M CHAP1 SIMM bad (806). D66 908-807 D C46 Description: RSS AG 16M CHAP1 SIMM bad (807). D66 908-808 D C45 Description: RSS AG 12M CHAP1 SIMM bad (808). D66 908-809 D C47 Description: RSS TX 16M CHAP1 SIMM bad (809). D66 908-810 D C46 Description: RSS base 16M CHAP2 SIMM bad (810). D66 908-811 D C45 Description: RSS base 12M CHAP2 SIMM bad (811). D66 908-812 D C46 Description: RSS AG 16M CHAP2 SIMM bad (812). D66 908-813 D C45 Description: RSS AG 12M CHAP2 SIMM bad (813). D66 908-814 D C47 Description: RSS TX 16M CHAP2 SIMM bad (814). D66 908-815 D C46 Description: RSS base 16M CHAP3 SIMM bad (815). D66 908-816 D C45 Description: RSS base 12M CHAP3 SIMM bad (816). D66 908-817 D C46 Description: RSS AG 16M CHAP3 SIMM bad (817). D66 908-818 D C45 Description: RSS AG 12M CHAP3 SIMM bad (818). D66 908-819 D C47 Description: RSS TX 16M CHAP3 SIMM bad (819). D66 908-820 D C46 Description: RSS base 16M CHAP4 SIMM bad (820). D66 908-821 D C45 Description: RSS base 12M CHAP4 SIMM bad (821). D66 908-822 D C46 Description: RSS AG 16M CHAP4 SIMM bad (822). D66 908-823 D C45 Description: RSS AG 12M CHAP4 SIMM bad (823). D66 908-824 D C47 Description: RSS TX 16M CHAP4 SIMM bad (824). D66 908-825 D C34 Description: RSS error. 908-830 D C34 Description: Multiple SIMMs failed. to 908-870 908-871 D D66 Description: RSS error. to 908-899 908-900 D D66 Description: RSS error. to C33 908-966 C48 908-967 D C35 Description: VOO error. to D66 908-969 C48 908-970 D D66 Description: RSS error. to C33 908-999 C48 912-102 D 912 Description: An unrecoverable media error. 912-104 D 912 Description: The motor failed to restart. 912-105 D 912 Description: The drive did not become ready. 912-106 D 912 Description: The electronics card test failed. 912-108 D 912 Description: The bus test failed. 912-110 D 912 Description: The media format is corrupted. 912-112 D 912 Description: The diagnostic test failed. 912-114 D 912 Description: An unrecoverable hardware error. 912-116 D Description: A protocol error. Action: Check the levels of the device, adapter, diagnostic software, and application software to be sure they are all compatible. If you do not find a problem, call your support person. 912-117 D 912 Description: A write protect error occurred. 912-118 D 912 Description: A SCSI command time-out. B88 912-120 D 912 Description: A SCSI busy or command error. 912-122 D 912 Description: A SCSI reservation conflict error. 912-124 D 912 Description: A SCSI check condition error. 912-126 D 912 Description: A software error was caused by a hardware failure. B88 912-128 G 912 Description: The error log analysis indicates a hardware failure. 912-129 G D50 Description: Error log analysis indicates a SCSI bus problem. 912 B88 software 912-130 G 912 Description: Error log analysis indicates a problem reported by the disk drive's self monitoring function. 912-132 D 912 Description: A disk drive hardware error occurred. 912-134 D B88 Description: The adapter failed to configure. software 912-137 D 912 Description: Unit attention condition has occurred on the Send Diagnostic B88 command. D50 913-102 D 913 Description: An unrecoverable media error. 913-104 D 913 Description: The motor failed to restart. 913-105 D 913 Description: The drive did not become ready. 913-106 D 913 Description: The electronics card test failed. 913-108 D 913 Description: The bus test failed. 913-110 D 913 Description: The media format is corrupted. 913-112 D 913 Description: The diagnostic test failed. 913-114 D 913 Description: An unrecoverable hardware error. 913-116 D Description: A protocol error. Action: Check the levels of the device, adapter, diagnostic software, and application software to be sure they are all compatible. If you do not find a problem, call your support person. 913-117 D 913 Description: A write protect error occurred. 913-118 D 913 Description: A SCSI command time-out. B88 913-120 D 913 Description: A SCSI busy or command error. 913-122 D 913 Description: A SCSI reservation conflict error. 913-124 D 913 Description: A SCSI check condition error. 913-126 D 913 Description: A software error was caused by a hardware failure. B88 913-128 G 913 Description: The error log analysis indicates a hardware failure. 913-129 G D50 Description: Error log analysis indicates a SCSI bus problem. 913 B88 software 913-130 G 913 Description: Error log analysis indicates a problem reported by the disk drive's self monitoring function. 913-132 D 913 Description: A disk drive hardware error occurred. 913-134 D B88 Description: The adapter failed to configure. software 913-137 D 913 Description: Unit attention condition has occurred on the Send Diagnostic B88 command. D50 914-110 D 914 Description: The Reserve command failed. 914-120 D 914 Description: The Inquiry command failed. 914-130 D 914 Description: The Load command failed. media 914-135 D 914 Description: The Unload command failed. media 914-140 D 914 Description: The Mode Select command failed. 914-150 D 914 Description: The Test Unit Ready command failed. media 914-160 D 914 Description: The Send Diagnostic command failed. media 914-170 D 914 Description: The Read, Write and Compare test failed. B88 media 914-180 D 914 Description: The Load command failed. media 914-185 D 914 Description: The Unload command failed. media 914-190 D 914 Description: The Mode Select command failed. 914-200 D 914 Description: The Test Unit Ready command failed. media 914-210 D 914 Description: The device configuration failed. B88 914-220 D 914 Description: The Release command failed. 914-230 D 914 Description: The Request Sense command failed. 914-240 D 914 Description: The Openx command failed. 914-300 D 914 Description: The device configuration failed. software 914-310 D B88 Description: SCSI adapter configuration failed. 914 software 914-320 G 914 Description: Error log analysis indicates a failure. media 914-411 D 914 Description: A reservation conflict to occurred. 914-423 B88 software 914-511 D 914 Description: The drive returned bad or to non-extended sense data. 914-523 B88 914-611 D 914 Description: An adapter or bus I/O error to occurred. 914-623 B88 software 914-711 D 914 Description: A device timeout error to occurred. 914-723 B88 software 915-110 D 915 Description: The Reserve command is corrupted. 915-120 D 915 Description: The Inquiry command failed. 915-130 D 915 Description: The Load command failed. media 915-135 D 915 Description: The Unload command failed. media 915-140 D 915 Description: The Mode Select command failed. 915-150 D 915 Description: The Test Unit Ready command failed. media 915-160 D 915 Description: The Send Diagnostic command failed. media 915-169 D 915 Description: The send diagnostic command failed. media 915-170 D 915 Description: The Read, Write and Compare test failed. B88 media 915-180 D 915 Description: The Load command failed. media 915-185 D 915 Description: The Unload command failed. media 915-190 D 915 Description: The Mode Select command failed. 915-200 D 915 Description: The Test Unit Ready command failed. media 915-210 D 915 Description: The device configuration failed. B88 915-220 D 915 Description: The Replace command failed. 915-230 D 915 Description: The Request Sense command failed. 915-240 D 915 Description: The Openx command failed. 915-300 D 915 Description: The device configuration failed. software 915-310 D B88 Description: SCSI adapter configuration failed. 915 software 915-320 G 915 Description: Error log analysis indicates a failure. media 915-411 D 915 Description: A reservation conflict to occurred. 915-423 B88 software 915-511 D 915 Description: The drive returned bad or to non-extended sense data. 915-523 B88 915-611 D 915 Description: An adapter or bus I/O error to occurred. 915-623 B88 software 915-711 D 915 Description: A device timeout error to occurred. 915-723 B88 software 917-102 D 917 Description: An unrecoverable media error. 917-104 D 917 Description: The motor failed to restart. 917-105 D 917 Description: The drive did not become ready. 917-106 D 917 Description: The electronics card test failed. 917-108 D 917 Description: The bus test failed. 917-110 D 917 Description: The media format is corrupted. 917-112 D 917 Description: The diagnostic test failed. 917-114 D 917 Description: An unrecoverable hardware error. 917-116 D Description: A protocol error. Action: Check the levels of the device, adapter, diagnostic software, and application software to be sure they are all compatible. If you do not find a problem, call your support person. 917-117 D 917 Description: A write protect error occurred. 917-118 D 917 Description: A SCSI command time-out. B88 917-120 D 917 Description: A SCSI busy or command error. 917-122 D 917 Description: A SCSI reservation conflict error. 917-124 D 917 Description: A SCSI check condition error. 917-126 D 917 Description: A software error was caused by a hardware failure. B88 917-128 G 917 Description: The error log analysis indicates a hardware failure. 917-129 G D50 Description: Error log analysis indicates a SCSI bus problem. 917 B88 software 917-130 G 917 Description: Error log analysis indicates a problem reported by the disk drive's self monitoring function. 917-132 D 917 Description: A disk drive hardware error occurred. 917-134 D B88 Description: The adapter failed to configure. software 917-135 D 917 Description: The device failed to configure. B88 software 917-136 D 917 Description: The certify operation failed. 917-137 D 917 Description: Unit attention condition has occurred on the Send Diagnostic B88 command. D50 918-102 D 918 Description: An unrecoverable media error. 918-104 D 918 Description: The motor failed to restart. 918-105 D 918 Description: The drive did not become ready. 918-106 D 918 Description: The electronics card test failed. 918-108 D 918 Description: The bus test failed. 918-110 D 918 Description: The media format is corrupted. 918-112 D 918 Description: The diagnostic test failed. 918-114 D 918 Description: An unrecoverable hardware error. 918-116 D Description: A protocol error. Action: Check the levels of the device, adapter, diagnostic software, and application software to be sure they are all compatible. If you do not find a problem, call your support person. 918-117 D 918 Description: A write protect error occurred. 918-118 D 918 Description: A SCSI command time-out. B88 918-120 D 918 Description: A SCSI busy or command error. 918-122 D 918 Description: A SCSI reservation conflict error. 918-124 D 918 Description: A SCSI check condition error. 918-126 D 918 Description: A software error was caused by a hardware failure. B88 918-128 G 918 Description: The error log analysis indicates a hardware failure. 918-129 G D50 Description: Error log analysis indicates a SCSI bus problem. 918 B88 software 918-130 G 918 Description: Error log analysis indicates a problem reported by the disk drive's self monitoring function. 918-132 D 918 Description: A disk drive hardware error occurred. 918-134 D B88 Description: The adapter failed to configure. software 918-135 D 918 Description: The device failed to configure. B88 software 918-136 D 918 Description: The certify operation failed. 918-137 D 918 Description: Unit attention condition has occurred on the Send Diagnostic B88 command. D50 921-101 D 821 Description: An unexpected adapter error occurred. 921-102 D 921 Description: An unexpected device or adapter error occurred. 821 921-103 D 921 Description: The keyboard reset failed. 821 921-104 D 921 Description: Unknown keyboard. 921-105 D 921 Description: The keyboard light on test failed. 821 921-106 D 921 Description: The keyboard light off test failed. 821 921-201 D 821 Description: An unexpected adapter error occurred. 921-202 D 921 Description: An unexpected device or adapter error occurred. 821 921-203 D 921 Description: The read keyboard ID test failed. 821 921-204 D 921 Description: The keyboard layout ID test failed. 921-205 D 921 Description: The keyboard echo test failed. 821 921-206 D 921 Description: The select scan code set test failed. 821 921-301 D 821 Description: An unexpected adapter error occurred. 921-302 D 921 Description: An unexpected device or adapter error occurred. 921-303 D 921 Description: An error occurred in turning on the lamps. 921-304 D 921 Description: An error occurred in turning off the lamps. 921-401 D 821 Description: An unexpected adapter error occurred. 921-402 D 921 Description: An unexpected device or adapter error occurred. 821 921-403 D 921 Description: Unable to recognize the keyboard. 921-404 D 921 Description: The keyboard is failing. 821 921-501 D 821 Description: An unexpected adapter error occurred. 921-502 D 921 Description: An unexpected device or adapter error occurred. 821 921-503 D 921 Description: The auto-click cannot be disabled. 921-504 D 921 Description: The auto-click cannot be enabled. 921-505 D 921 Description: Unable to recognize the keyboard. 921-601 D 821 Description: An unexpected adapter error occurred. 921-602 D 921 Description: An unexpected device or adapter error occurred. 821 921-603 D 921 Description: The speaker test failed. 921-701 D 921 Description: Error configuring the device. 821 921-901 G 821 Description: The error log analysis indicates an adapter failure. 921-902 G 921 Description: The error log analysis indicates a device failure. 821 921-903 G 921 Description: The error log analysis indicates an unknown failure. 821 922-101 D 821 Description: An unexpected adapter error occurred. 922-102 D 922 Description: An unexpected device or adapter error occurred. 821 922-103 D 922 Description: The keyboard reset failed. 821 922-104 D 922 Description: Unknown keyboard. 922-105 D 922 Description: The keyboard light on test failed. 821 922-106 D 922 Description: The keyboard light off test failed. 821 922-201 D 821 Description: An unexpected adapter error occurred. 922-202 D 922 Description: An unexpected device or adapter error occurred. 821 922-203 D 922 Description: The read keyboard id test failed. 821 922-204 D 922 Description: The keyboard layout id test failed. 922-205 D 922 Description: The keyboard echo test failed. 821 922-206 D 922 Description: The select scan code set test failed. 821 922-301 D 821 Description: An unexpected adapter error occurred. 922-302 D 922 Description: An unexpected device or adapter error occurred. 821 922-303 D 922 Description: An error occurred in turning on the lamps. 922-304 D 922 Description: An error occurred in turning off the lamps. 922-401 D 821 Description: An unexpected adapter error occurred. 922-402 D 922 Description: An unexpected device or adapter error occurred. 821 922-403 D 922 Description: The keyboard is failing. 922-404 D 922 Description: Unable to recognize the keyboard. 821 922-501 D 821 Description: An unexpected adapter error occurred. 922-502 D 922 Description: An unexpected device or adapter error occurred. 821 922-503 D 921 Description: The auto-click cannot be disabled. 922-504 D 922 Description: The auto-click cannot be enabled. 922-505 D 922 Description: Unable to recognize the keyboard. 922-601 D 821 Description: An unexpected adapter error occurred. 922-602 D 922 Description: An unexpected device or adapter error occurred. 821 922-603 D 922 Description: The speaker test failed. 922-701 D 922 Description: Error configuring the device. 821 922-901 G 821 Description: The error log indicates an adapter failed. 922-902 G 922 Description: The error log indicates a device failed. 821 922-903 G 922 Description: The error log analysis indicates an unknown failure. 821 923-101 D 821 Description: An unexpected adapter error occurred. 923-102 D 923 Description: An unexpected device or adapter error occurred. 821 923-103 D 923 Description: The keyboard reset failed. 821 923-104 D 923 Description: Unknown keyboard. 923-105 D 923 Description: The keyboard light on test failed. 821 923-106 D 923 Description: The keyboard light off test failed. 821 923-201 D 821 Description: An unexpected adapter error occurred. 923-202 D 923 Description: An unexpected device or adapter error occurred. 821 923-203 D 923 Description: The read keyboard id test failed. 821 923-204 D 923 Description: The keyboard layout id test failed. 923-205 D 923 Description: The keyboard echo test failed. 821 923-206 D 923 Description: The select scan code set test failed. 821 923-301 D 821 Description: An unexpected adapter error occurred. 923-302 D 923 Description: An unexpected device or adapter error occurred. 821 923-303 D 923 Description: An error occurred in turning on the lamps. 923-304 D 923 Description: An error occurred in turning off the lamps. 923-401 D 821 Description: An unexpected adapter error occurred. 923-402 D 923 Description: An unexpected device or adapter error occurred. 821 923-403 D 923 Description: The keyboard is failing. 923-404 D 923 Description: Unable to recognize the keyboard. 821 923-501 D 821 Description: An unexpected adapter error occurred. 923-502 D 923 Description: An unexpected device or adapter error occurred. 821 923-503 D 923 Description: The auto-click cannot be disabled. 923-504 D 923 Description: The auto-click cannot be enabled. 923-505 D 923 Description: Unable to recognize the keyboard. 923-601 D 821 Description: An unexpected adapter error occurred. 923-602 D 923 Description: An unexpected device or adapter error occurred. 821 923-603 D 923 Description: The speaker test failed. 922-701 D 923 Description: Error configuring the device. 821 923-901 G 821 Description: The error log indicates an adapter failed. 923-902 G 923 Description: The error log analysis indicates a device failure. 821 923-903 G 923 Description: The error log analysis indicates an unknown failure. 821 925-111 D 925 Description: An unexpected device error occurred. 823 925-112 D 925 Description: The device disable test failed. 823 925-113 D 925 Description: Could not reset the device. 925-114 D 925 Description: The read status command failed. 823 925-115 D 925 Description: The device test failed. 925-116 D 925 Description: Unknown Mouse type. 925-117 D 925 Description: Mouse wrap mode failed. 823 925-118 D 925 Description: Error setting mouse parameters. 823 925-121 D 925 Description: The device test failed. to 925-171 925-200 D 925 Description: A software error was caused by a hardware failure. 823 925-300 G 925 Description: The error log analysis indicates a hardware failure. 925-301 G 925 Description: The error log analysis indicates a hardware failure. 823 926-104 D 926 Description: Input device cable is not attached. 159 926-111 D 824 Description: Adapter error. 926-112 D 926 Description: Device, adapter or tablet 926-115 reset failed. 824 926-116 D 159 Description: The input device cable is not attached. 926-119 D 188 Description: The input device cable is not attached. 926-121 D 824 Description: Adapter error. 926-131 D 824 Description: Adapter error. 926 926-132 D 926 Description: Device or adapter error. to 926-135 926-141 D 824 Description: Adapter error. 926 926-142 D 926 Description: Device or adapter error. to 926-161 926-162 D 159 Description: Device or adapter error. 926 926-163 D 159 Description: Error in turning off input device LED. 926 926-164 D 159 Description: Error in turning off input device LED. 926 926-165 D 159 Description: The input device cable is not attached. 926-166 D 188 Description: Device or adapter error. 926 926-167 D 188 Description: Error in turning off input device LED. 926 926-168 D 188 Description: Error in turning on input device LED. 926 926-169 D 188 Description: The input device cable is not attached. 926-172 D 159 Description: Device or adapter error. 926 926-173 D 159 Description: Error in turning off input device switch. 926 926-174 D 159 Description: Error in turning on input device switch. 926 926-175 D 159 Description: The input device cable is not attached. 926-176 D 188 Description: Device or adapter error. 926 926-177 D 188 Description: Error in turning off input device switch. 926 926-178 D 188 Description: Error in turning on input device switch. 926 926-179 D 188 Description: The input device cable is not attached. 926-181 D 824 Description: Adapter error. 926 926-182 D 159 Description: Device or adapter error. 926 926-183 D 159 Description: Error in incremental data mode test. 926 926-184 D 159 Description: The input device cable is not attached. 926-186 D 188 Description: Device or adapter error. 926 926-187 D 188 Description: The incremental data mode test failed. 926 926-188 D 188 Description: The input device cable is not attached. 926-203 D 926 Description: Error in disabling tablet. 824 926-204 D 926 Description: Error in enabling tablet. 824 926-207 D 926 Description: Enabled/disabled test failed. 824 926-208 D 926 Description: Enabled/disabled test failed. 824 926-221 D 824 Description: Adapter error. 926-222 D 926 Description: Device or adapter error. 824 926-225 D 159 Description: The input device cable is not attached. 926-229 D 188 Description: The input device cable is not attached. 926-271 D 926 Description: Adapter error. 926-272 D 159 Description: Device or adapter error. 926 926-273 D 159 Description: Error in input device switch test. 926-274 D 159 Description: The input device cable is not attached. 926-276 D 188 Description: Device or adapter error. 926 926-277 D 188 Description: Error in input device switch test. 926 926-278 D 188 Description: Input device cable is not attached. 926-281 D 824 Description: Adapter error. 926 926-282 D 159 Description: Device or adapter error. 926 926-283 D 159 Description: Error in incremental data mode test. 926 926-284 D 159 Description: The input device cable is not attached. 926-286 D 188 Description: Device or adapter error. 926 926-287 D 188 Description: Error in incremental data mode test. 926 926-288 D 188 Description: The input device cable is not attached. 927-104 D 927 Description: The input device cable is not attached. 159 927-111 D 824 Description: Adapter error. 927-112 D 927 Description: Device or adapter error. 824 927-113 D 927 Description: Tablet reset failed. 824 927-114 D 927 Description: The read configuration test failed. 824 927-115 D 927 Description: The read status test failed. 824 927-116 D 159 Description: The input device cable is not attached. 927-119 D 188 Description: The input device cable is not attached. 927-121 D 824 Description: Adapter error. 927-122 D 927 Description: Device or adapter error. 824 927-125 D 927 Description: The input device cable is not attached. 824 927-131 D 824 Description: Adapter error. 927 927-132 D 927 Description: Device or adapter error. 927-133 D 927 Description: The set conversion mode test failed. 927-134 D 927 Description: The set resolution test failed. 927-135 D 927 Description: The read status test failed. 927-141 D 824 Description: Adapter error. 927 927-142 D 927 Description: Device or adapter error. 927-143 D 927 Description: Error in tablet indicator. 927-161 D 927 Description: Adapter error. 927-162 D 159 Description: Device or adapter error. 927 927-163 D 159 Description: Error in turning off input device LED. 927 927-164 D 159 Description: Error in turning on input device LED. 927 927-165 D 159 Description: The input device cable is not attached. 927-166 D 188 Description: Device or adapter error. 927 927-167 D 188 Description: Error in turning off input device LED. 927 927-168 D 188 Description: Error in turning on input device LED. 927 927-169 D 188 Description: The input device cable is not attached. 927-171 D 927 Description: Adapter error. 927-172 D 159 Description: Device or adapter error. 927 927-173 D 159 Description: Error in turning off input device switch. 927 927-174 D 159 Description: Error in turning on input device switch. 927 927-175 D 159 Description: The input device cable is not attached. 927-176 D 188 Description: Device or adapter error. 927 927-177 D 188 Description: Error in turning off input device switch. 927 927-178 D 188 Description: Error in turning on input device switch. 927 927-179 D 188 Description: The input device cable is not attached. 927-181 D 824 Description: Adapter error. 927 927-182 D 159 Description: Device or adapter error. 927 927-183 D 159 Description: Error in incremental data mode test. 927 927-184 D 159 Description: The input device cable is not attached. 927-186 D 188 Description: Device or adapter error. 927 927-187 D 188 Description: Error in incremental data mode test. 927 927-188 D 188 Description: The input device cable is not attached. 927-203 D 927 Description: Error in disabling tablet. 824 927-204 D 927 Description: Error in enabling tablet. 824 927-221 D 824 Description: Adapter error. 927-222 D 927 Description: Device or adapter error. 824 927-225 D 159 Description: The input device cable is not attached. 927-229 D 188 Description: The input device cable is not attached. 927-271 D 927 Description: Adapter error. 927-272 D 159 Description: Device or adapter error. 927 927-273 D 159 Description: Error in input device switch test. 927 927-274 D 159 Description: The input device cable is not attached. 927-276 D 188 Description: Device or adapter error. 927 927-277 D 188 Description: Error in input device switch test. 927 927-278 D 188 Description: The input device cable is not attached. 927-281 D 824 Description: Adapter error. 927 927-282 D 159 Description: Device or adapter error. 927 927-283 D 159 Description: Error in incremental data mode test. 927 927-284 D 159 Description: The input device cable is not attached. 927-286 D 188 Description: Device or adapter error. 927 927-287 D 188 Description: Error in incremental data mode test. 927 927-288 D 188 Description: The input device cable is not attached. 929-201 Description: Failed to register input D 929 ring 929-202 Description: Unable to read event from D 929 the device 929-203 Description: Unable to communicate with D 929 the device. 929-204 Description: Cannot set the device D 929 granularity 929-210 Description: Device or adapter failure D 929 929-212 Description: Cannot set the device to D 929 HIGH granularity 929-213 Description: Cannot set the device to D 929 LOW granularity 929-299 software Description: Error unconfiguring the D 929 device 929-301 Description: Error configuring the D software device 929 930-201 Description: Device or adapter failure D 930 930-210 Description: Unable to turn the lights G 930 on 930-220 Description: Unable to turn the lights G 930 off hardware failure. 930-230 Description: Unable to turn the lights D 930 off 930-241 Description: Unable to turn a single D 930 light on 930-242 Description: Device or adapter failure D 930 930-243 Description: Device or adapter failure D 930 930-261 Description: Cable test failed D 930 930-262 Description: Cable test failed D 930 930-299 Description: Error unconfiguring the D software device 930 930-301 Description: Error configuring the D software device 930 935-101 D 935 Description: The diskette-drive select or deselect test failed. to 828 935-102 935-103 D 935 Description: The diskette failed. to 935-107 828 935-108 D 935 Description: The diskette read test failed. 935-109 D 935 Description: The read/write on the diskette drive failed. to 828 935-110 935-111 D 935 Description: A diskette drive test to failed. 935-114 935-115 D 935 Description: The diskette drive test to failed. 935-121 828 935-122 G 935 Description: The error log analysis indicates a hardware failure. 828 935-123 G 935 Description: The error log analysis indicates a hardware failure. 935-124 D 935 Description: Unable to configure the device. software 945-102 D 990 Description: 1GB 16-bit SCSI to differential disk drive problem. 945-114 945-116 D Description: A protocol error. Action: Check the levels of the device, adapter, diagnostic software, and application software to be sure they are all compatible. If you do not find a problem, call your support person. 945-117 D 990 Description: A write protect error occurred. 945-118 D 990 Description: A SCSI command time-out. B88 945-120 D 990 Description: 1GB 16-bit SCSI to differential disk drive problem. 945-124 945-126 D 990 Description: A software error was caused by a hardware failure. B88 945-128 G 990 Description: The error log analysis indicates a hardware failure. 945-129 G D50 Description: Error log analysis indicates a SCSI bus problem. 945 B88 software 945-130 G 945 Description: Error log analysis indicates a problem reported by the disk drive's self monitoring function. 945-132 D 990 Description: A disk drive hardware error occurred. 945-134 D B88 Description: The adapter failed to configure. software 945-136 D 990 Description: The certify operation failed. 945-137 D 945 Description: Unit attention condition has occurred on the Send Diagnostic B88 command. D50 946-111 Description: Cannot run the test D 946 because the device driver detected a 227 hardware error. 946-114 Description: The register verification D 946 test failed. 946-121 Description: Cannot run the test D 946 because the device driver detected a 227 hardware error. 946-122 Description: The data wrap D 946 communications test failed. 227 946-123 Description: The modem control line D 946 test failed. 227 946-131 Description: Cannot run the test D 946 because the device driver detected a hardware error. 946-132 Description: The data wrap D 946 communications test failed. 227 946-133 Description: The modem control line D 946 test failed. 946-161 Description: Could not do the test D 252 because the device driver detected a hardware error. 946-162 Description: The data wrap D 252 communication test failed. 946-163 Description: The modem control line D 252 test failed. 946-171 Description: Cannot run the test D 259 because the device driver detected a hardware error. 946-172 Description: The data wrap D 259 communications test failed. 946-173 Description: The modem control line D 259 test failed. 946-181 Description: Cannot run the test D 261 because the device driver detected a hardware error. 946-182 Description: The data wrap D 261 communications test failed. 946-183 Description: The modem control line D 261 test failed. 946-271 Description: Cannot run the test D 946 because the device driver detected a 259 hardware error. 946-272 Description: The data wrap D 946 communication test failed. 259 946-273 Description: The modem control line D 946 test failed. 259 946-281 Description: Cannot run the test D 946 because the device driver detected a 261 hardware error. 946-282 Description: The data wrap D 946 communications test failed. 261 946-283 Description: The modem control line D 946 test failed. 261 946-321 Description: Cannot run the test D 946 because the device driver detected a hardware error. 946-322 Description: The data wrap D 946 communications test failed. 946-323 Description: The modem control line D 946 test failed. 946-331 Description: Cannot run the test D 946 because the device driver detected a hardware error. 946-332 Description: The data wrap D 946 communications test failed. 946-333 Description: The modem control line D 946 test failed. 946-371 Description: Cannot run the test D 946 because the device driver detected a hardware error. 946-372 Description: The data wrap D 946 communications test failed. 946-373 Description: The modem control line D 946 test failed. 946-381 Description: Cannot run the test D 946 because the device driver detected a hardware error. 946-382 Description: The data wrap D 946 communications test failed. 946-383 Description: The modem control line D 946 test failed. 946-481 Description: Could not do the test D D56 because the device driver detected a hardware error. Description: The data wrap 946-482 D D56 communication test failed. 946-483 Description: The modem control line D D56 test failed. 946-581 Description: Could not do the test D 946 because the device driver detected a D56 hardware error. 946-582 Description: The data wrap D 946 communication test failed. D56 946-583 Description: The modem control line D 946 test failed. D56 946-901 D software Description: An unexpected error occurred that can be attributed to to 946 software or hardware. 946-920 Action: Run diagnostics from a source other than from the disk or a network. If the same error occurs or if the original SRN was not obtained from disk or a network based diagnostics, use Chapter 12. "MAP 0210: General Problem Resolution" with a FFC of 946; otherwise, suspect a software problem. 946-921 D 946 Description: The adapter failed to configure software 946-922 D software Description: An unexpected error occurred that can be attributed to to 946 software or hardware. 946-924 Action: Run diagnostics from a source other than from the disk or a network. If the same error occurs or if the original SRN was not obtained from disk or a network based diagnostics, use Chapter 12. "MAP 0210: General Problem Resolution" with a FFC of 946; otherwise, suspect a software problem. 946-925 D 946 Description: The adapter failed to configure software 946-926 D software Description: An unexpected error occurred that can be attributed to to 946 software or hardware. 946-943 Action: Run diagnostics from a source other than from the disk or a network. If the same error occurs or if the original SRN was not obtained from disk or a network based diagnostics, use Chapter 12. "MAP 0210: General Problem Resolution" with a FFC of 946; otherwise, suspect a software problem. 950-100 C 192 Description: Power supply problem. Action: Use the service documentation for the portable disk. 950-101 F 2C9 Description: PCI bus was not found. Action: Rerun diagnostics in Advanced 153 Mode for additional problem isolation. 950-102 C 2C9 Description: PCI bus was not found. 950-103 C 2C9 Description: Multiple adapters on bus were not found. 950-105 C 2C9 Description: PCI bus was not found. 221 950-106 C 2C9 Description: PCI bus was not found. 950-107 C 153 Description: The device is not responding 165 Action: For devices located in drawer/deskside units, use the service documentation for the drawer/deskside unit. For all other locations, use Chapter 12. "MAP 0210: General Problem Resolution". 950-108 C 201 Description: The device is not responding. Action: For devices located 199 in drawer/deskside units, use the service documentation for the drawer/deskside 153 unit. For all other locations, use Chapter 12. "MAP 0210: General Problem 165 Resolution". 950-200 C 203 Description: Power supply problem. Action: Use the service documentation for the external device. 950-201 C SCSI Bus Description: SCSI bus problem. Action: Refer to MAP 2010 in the 7134 High Density SCSI Disk Subsystem Installation and Service Guide. 950-400 C 153 Description: Power supply problem. Action: Use the service documentation for the drawer/tower containing the failing power supply. If the drawer/deskside unit service documentation does not isolate the problem, go to MAP 1520 in the system unit installation and service guide. 950-500 C 152 Description: Power supply problem. Action: Use the service documentation for either the system unit, rack or drawer/deskside unit the missing device is located in. 950-679 C 679 Description: The SCSI Disk Drive is not responding. B88 Action: For devices located in drawer/deskside units, use the service 190 documentation for the drawer/deskside unit. For all other locations, use 199 Chapter 12. "MAP 0210: General Problem Resolution". 152 950-700 C 700 Description: The device is not responding. B88 Action: For devices located in drawer/deskside units, use the service 152 documentation for the drawer/deskside unit. For all other locations, use Chapter 12. "MAP 0210: General Problem Resolution". 950-701 C 701 Description: The device is not responding. B88 Action: For devices located in drawer/deskside units, use the service 152 documentation for the drawer/deskside unit. For all other locations, use Chapter 12. "MAP 0210: General Problem Resolution". 950-702 C 702 Description: The device is not responding. B88 Action: For devices located in drawer/deskside units, use the service 152 documentation for the drawer/deskside unit. For all other locations, use Chapter 12. "MAP 0210: General Problem Resolution". 950-703 C 703 Description: The device is not responding. B88 Action: For devices located in drawer/deskside units, use the service 152 documentation for the drawer/deskside unit. For all other locations, use Chapter 12. "MAP 0210: General Problem Resolution". 950-704 C 704 Description: The device is not responding. B88 Action: For devices located in drawer/deskside units, use the service 152 documentation for the drawer/deskside unit. For all other locations, use Chapter 12. "MAP 0210: General Problem Resolution". 950-705 C 705 Description: The device is not responding. B88 Action: For devices located in drawer/deskside units, use the service 152 documentation for the drawer/deskside unit. For all other locations, use Chapter 12. "MAP 0210: General Problem Resolution". 950-706 C 706 Description: The device is not responding. B88 Action: For devices located in drawer/deskside units, use the service 152 documentation for the drawer/deskside unit. For all other locations, use Chapter 12. "MAP 0210: General Problem Resolution". 950-707 C 707 Description: The device is not responding. B88 Action: For devices located in drawer/deskside units, use the service 152 documentation for the drawer/deskside unit. For all other locations, use Chapter 12. "MAP 0210: General Problem Resolution". 950-721 C 721 Description: An unknown drive type is not responding. B88 152 950-722 C 722 Description: The device is not responding. B88 Action: For devices located in drawer/deskside units, use the service 152 documentation for the drawer/deskside unit. For all other locations, use Chapter 12. "MAP 0210: General Problem Resolution". 950-723 C 723 Description: The device is not responding. B88 Action: For devices located in drawer/deskside units, use the service 152 documentation for the drawer/deskside unit. For all other locations, use Chapter 12. "MAP 0210: General Problem Resolution". 950-724 C 724 Description: The device is not responding. B88 Action: For devices located in drawer/deskside units, use the service 152 documentation for the drawer/deskside unit. For all other locations, use Chapter 12. "MAP 0210: General Problem Resolution". 950-734 C 734 Description: The device is not responding. B88 Action: For devices located in drawer/deskside units, use the service 152 documentation for the drawer/deskside unit. For all other locations, use Chapter 12. "MAP 0210: General Problem Resolution". 950-741 C 741 Description: Device does not respond. Action: For devices located in B88 drawer/deskside units, use the service documentation for the drawer/deskside 152 units. For all other locations, use Chapter 12. "MAP 0210: General Problem Resolution". 950-772 C 772 Description: Device does not respond. Action: For devices located in B88 drawer/deskside units, use the service documentation for the drawer/deskside 199 units. For all other locations, use Chapter 12. "MAP 0210: General Problem 152 Resolution". 950-773 C 773 Description: Device does not respond. Action: For devices located in B88 drawer/deskside units, use the service documentation for the drawer/deskside 152 units. For all other locations, use Chapter 12. "MAP 0210: General Problem Resolution". 950-789 C 789 Description: Device does not respond. Action: For devices located in B88 drawer/deskside units, use the service documentation for the drawer/deskside 152 units. For all other locations, use Chapter 12. "MAP 0210: General Problem Resolution". 950-792 C 792 Description: Device does not respond. Action: For devices located in B88 drawer/deskside units, use the service documentation for the drawer/deskside 152 units. For all other locations, use Chapter 12. "MAP 0210: General Problem Resolution". 950-793 C 793 Description: Device does not respond. Action: For devices located in B88 drawer/deskside units, use the service documentation for the drawer/deskside 152 units. For all other locations, use Chapter 12. "MAP 0210: General Problem Resolution". 950-804 C 804 Description: The device is not responding. B88 Action: For devices located in drawer/deskside units, use the service 152 documentation for the drawer/deskside unit. For all other locations, use Chapter 12. "MAP 0210: General Problem Resolution". 950-912 C 912 Description: Device does not respond. Action: For devices located in B88 drawer/deskside units, use the service documentation for the drawer/deskside 152 units. For all other locations, use Chapter 12. "MAP 0210: General Problem Resolution". 950-914 C 914 Description: Device does not respond. Action: For devices located in B88 drawer/deskside units, use the service documentation for the drawer/deskside 152 units. For all other locations, use Chapter 12. "MAP 0210: General Problem Resolution". 950-915 C 915 Description: Device does not respond. Action: For devices located in B88 drawer/deskside units, use the service documentation for the drawer/deskside 152 units. For all other locations, use Chapter 12. "MAP 0210: General Problem Resolution". 950-917 C 917 Description: Device does not respond. Action: For devices located in B88 drawer/deskside units, use the service documentation for the drawer/deskside 152 units. For all other locations, use Chapter 12. "MAP 0210: General Problem Resolution". 950-918 C 918 Description: Device does not respond. Action: For devices located in B88 drawer/deskside units, use the service documentation for the drawer/deskside 152 units. For all other locations, use Chapter 12. "MAP 0210: General Problem Resolution". 950-935 C 935 Description: Device does not respond. 828 152 199 950-936 C 936 Description: Device does not respond. 828 152 950-951 C 951 Description: Device does not respond. Action: For devices located in B88 drawer/deskside units, use the service documentation for the drawer/deskside 152 units. For all other locations, use Chapter 12. "MAP 0210: General Problem Resolution". 950-952 C 952 Description: Device does not respond. Action: For devices located in B88 drawer/deskside units, use the service documentation for the drawer/deskside 152 units. For all other locations, use Chapter 12. "MAP 0210: General Problem Resolution". 950-953 C 953 Description: Device does not respond. Action: For devices located in B88 drawer/deskside units, use the service documentation for the drawer/deskside 152 units. For all other locations, use Chapter 12. "MAP 0210: General Problem Resolution". 950-954 C 954 Description: Device does not respond. Action: For devices located in B88 drawer/deskside units, use the service documentation for the drawer/deskside 152 units. For all other locations, use Chapter 12. "MAP 0210: General Problem Resolution". 950-955 C 955 Description: Device does not respond. Action: For devices located in B88 drawer/deskside units, use the service documentation for the drawer/deskside 141 units. For all other locations, use Chapter 12. "MAP 0210: General Problem 152 Resolution". If the drawer/deskside unit service documentation does not isolate the problem, go to Chapter 12. "MAP 0210: General Problem Resolution". 950-956 C 956 Description: Device does not respond. Action: For devices located in B88 drawer/deskside units, use the service documentation for the drawer/deskside 152 units. For all other locations, use Chapter 12. "MAP 0210: General Problem Resolution". 950-959 C 959 Description: Device does not respond. Action: For devices located in B88 drawer/deskside units, use the service documentation for the drawer/deskside 152 units. For all other locations, use Chapter 12. "MAP 0210: General Problem Resolution". 950-960 C 960 Description: Device does not respond. B88 152 950-968 C 968 Description: Device does not respond. B88 152 950-970 C 970 Description: Device does not respond. Action: For devices located in B88 drawer/deskside units, use the service documentation for the drawer/deskside 152 units. For all other locations, use Chapter 12. "MAP 0210: General Problem Resolution". 950-971 C 971 Description: Device does not respond. Action: For devices located in B88 drawer/deskside units, use the service documentation for the drawer/deskside 152 units. For all other locations, use Chapter 12. "MAP 0210: General Problem Resolution". 950-972 C 972 Description: Device does not respond. Action: For devices located in B88 drawer/deskside units, use the service documentation for the drawer/deskside 152 units. For all other locations, use Chapter 12. "MAP 0210: General Problem Resolution". 950-974 C 974 Description: Device does not respond. Action: For devices located in B88 drawer/deskside units, use the service documentation for the drawer/deskside 152 units. For all other locations, use Chapter 12. "MAP 0210: General Problem Resolution". 950-981 C 981 Description: Device does not respond. Action: For devices located in B88 drawer/deskside units, use the service documentation for the drawer/deskside 152 units. Refer to "Drawer/Deskside Unit Documentation" under Service Hints in Chapter 1. For all other locations, use Chapter 12. "MAP 0210: General Problem Resolution". 950-984 C 984 Description: Device does not respond. Action: For devices located in B88 drawer/deskside units, use the service documentation for the drawer/deskside 152 units. For all other locations, use Chapter 12. "MAP 0210: General Problem Resolution". 950-986 C 986 Description: Device does not respond. Action: For devices located in B88 drawer/deskside units, use the service documentation for the drawer/deskside 152 units. For all other locations, use Chapter 12. "MAP 0210: General Problem Resolution". 950-987 C 974 Description: Device does not respond. Action: For devices located in B88 drawer/deskside units, use the service documentation for the drawer/deskside 152 units. For all other locations, use Chapter 12. "MAP 0210: General Problem Resolution". 950-989 C 989 Description: Device does not respond. Action: For devices located in B88 drawer/deskside units, use the service documentation for the drawer/deskside 152 units. For all other locations, use Chapter 12. "MAP 0210: General Problem Resolution". 950-990 C 990 Description: Device does not respond. Action: For devices located in B88 drawer/deskside units, use the service documentation for the drawer/deskside 152 units. For all other locations, use Chapter 12. "MAP 0210: General Problem Resolution". 950-991 C 991 Description: Device does not respond. B88 152 950-994 C 994 Description: Device does not respond. Action: For devices located in B88 drawer/deskside units, use the service documentation for the drawer/deskside 152 units. For all other locations, use Chapter 12. "MAP 0210: General Problem Resolution". 950-995 C 995 Description: Device does not respond. Action: For devices located in B88 drawer/deskside units, use the service documentation for the drawer/deskside 152 units. For all other locations, use Chapter 12. "MAP 0210: General Problem Resolution". 950-998 C 998 Description: Device does not respond. Action: For devices located in B88 drawer/deskside units, use the service documentation for the drawer/deskside 152 units. For all other locations, use Chapter 12. "MAP 0210: General Problem Resolution". 950-xxx C xxx Description: The device does not respond. (See note B88 Action: For devices located in in the drawer/deskside units, use the service 152 documentation for the drawer/deskside Action units. Refer to "Drawer/Deskside Unit col.) Documentation" under Service Hints in Chapter 1. For all other locations use Chapter 12. "MAP 0210: General Problem Resolution". Note: If your 950-xxx SRN is listed in this section, use the procedure for that SRN instead of this one. Otherwise, to obtain the FFC substitute the last three digits of the SRN for xxx. (The substituted three digit number is the FFC.) 951-098 Description: Disk drive indicates an J 951 error. 951-099 Description: Disk drive not found. J 951 B88 951-102 Description: An unrecoverable media D 951 error. 951-104 Description: The motor failed to D 951 restart. 951-105 Description: The drive did not become D 951 ready. 951-106 Description: The electronics card test D 951 failed. 951-108 Description: The bus test failed. D 951 951-110 Description: The media format is D 951 corrupted. 951-112 Description: The diagnostic test D 951 failed. 951-114 Description: An unrecoverable hardware D 951 error. 951-116 Description: A protocol error. D Action: Check the levels of the device, adapter, diagnostic software, and application software to ensure they are all compatible. If you do not find a problem, call your support person. 951-117 Description: A write protect error D 951 occurred. 951-118 Description: A SCSI command timeout. D 951 B88 951-120 Description: A SCSI busy or command D 951 error. 951-122 Description: A SCSI reservation D 951 conflict error. 951-124 Description: A SCSI check condition D 951 error. 951-126 Description: A software error was D 951 caused by a hardware failure. B88 951-128 Description: The error log analysis G 951 indicates a hardware failure. 951-129 G D50 Description: Error log analysis indicates a SCSI bus problem. 951 B88 software 951-130 G 951 Description: Error log analysis indicates a problem reported by the disk drive's self monitoring function. 951-132 Description: A disk drive hardware D 951 error occurred. 951-134 Description: The adapter failed to D B88 configure. software 951-135 Description: The device failed to D 951 configure. B88 software 951-136 Description: The certify operation D 951 failed. 951-137 D 951 Description: Unit attention condition has occurred on the Send Diagnostic B88 command. D50 952-098 Description: Disk drive indicates an J 952 error. 952-099 Description: Disk drive not found. J 952 B88 952-102 Description: An unrecoverable media D 952 error. 952-104 Description: The motor failed to D 952 restart. 952-105 Description: The drive did not become D 952 ready. 952-106 Description: The electronics card test D 952 failed. 952-108 Description: The bus test failed. D 952 952-110 Description: The media format is D 952 corrupted. 952-112 Description: The diagnostic test D 952 failed. 952-114 Description: An unrecoverable hardware D 952 error. 952-116 Description: A protocol error. D Action: Check the levels of the device, adapter, diagnostic software, and application software to be sure they are all compatible. If you do not find a problem, call your support person. 952-117 Description: A write protect error D 952 occurred. 952-118 Description: A SCSI command timeout. D 952 B88 952-120 Description: A SCSI busy or command D 952 error. 952-122 Description: A SCSI reservation D 952 conflict error. 952-124 Description: A SCSI check condition D 952 error. 952-126 Description: A software error was D 952 caused by a hardware failure. B88 952-128 Description: The error log analysis G 952 indicates a hardware failure. 952-129 G D50 Description: Error log analysis indicates a SCSI bus problem. 952 B88 software 952-130 G 952 Description: Error log analysis indicates a problem reported by the disk drive's self monitoring function. 952-132 Description: A disk drive hardware D 952 error occurred. 952-134 Description: The adapter failed to D B88 configure. software 952-135 Description: The device failed to D 952 configure. B88 software 952-136 Description: The certify operation D 952 failed. 952-137 D 952 Description: Unit attention condition has occurred on the Send Diagnostic B88 command. D50 953-098 Description: Disk drive indicates an J 953 error. 953-099 Description: Disk drive not found. J 953 B88 953-102 Description: An unrecoverable media D 953 error. 953-104 Description: The motor failed to D 953 restart. 953-105 Description: The disk drive did not D 953 become ready. 953-106 Description: The electronics card test D 953 failed. 953-108 Description: The bus test failed. D 953 953-110 Description: The media format is D 953 corrupted. 953-112 Description: The diagnostic test D 953 failed. 953-114 Description: An unrecoverable hardware D 953 error. 953-116 Description: A protocol error. D Action: Check the levels of the device, adapter, diagnostic software, and application software to be sure they are all compatible. If you do not find a problem, call your support person. 953-117 Description: A write protect error. D 953 953-118 Description: A SCSI command timeout. D 953 B88 953-120 Description: A SCSI busy or command D 953 error. 953-122 Description: A SCSI reservation D 953 conflict error. 953-124 Description: A SCSI check condition D 953 error. 953-126 Description: A software error was D 953 caused by a hardware failure. B88 953-128 Description: The error log analysis G 953 indicates a hardware failure. 953-129 G D50 Description: Error log analysis indicates a SCSI bus problem. 953 B88 software 953-130 G 953 Description: Error log analysis indicates a problem reported by the disk drive's self monitoring function. 953-132 Description: A disk drive hardware D 953 error occurred. 953-134 Description: The adapter failed to D B88 configure. software 953-135 Description: The device failed to D 953 configure. B88 software 953-136 Description: The certify operation D 953 failed. 953-137 D 953 Description: Unit attention condition has occurred on the Send Diagnostic B88 command. D50 954-098 Description: Disk drive indicates an J 954 error. 954-099 Description: Disk drive not found. J 954 B88 954-102 Description: An unrecoverable media D 954 error. 954-104 Description: Motor failed to restart. D 954 954-105 Description: The disk drive did not D 954 become ready. 954-106 Description: Electronics card failure. D 954 954-108 Description: Bus failure. D 954 954-110 Description: The media format is D 954 corrupted. 954-112 Description: Diagnostic failure. D 954 954-114 Description: An unrecoverable hardware D 954 error. 954-116 Description: A protocol error was D detected. Action: Check the levels of the device, adapter, diagnostic software, and application software, ensure that they are all compatible. If you do not find a problem, call your support person. 954-117 Description: Write protect error. D 954 954-118 Description: SCSI command timeout. D 954 B88 954-120 Description: SCSI busy/command error. D 954 954-122 Description: SCSI reservation conflict D 954 error. 954-124 Description: SCSI check condition D 954 error. 954-126 Description: Software error caused by D 954 hardware failure. B88 954-128 Description: Error log analysis G 954 indicates hardware failure. 954-129 G D50 Description: Error log analysis indicates a SCSI bus problem. 954 B88 software 954-130 G 954 Description: Error log analysis indicates a problem reported by the disk drive's self monitoring function. 954-132 Description: A disk drive hardware D 954 error occurred. 954-134 Description: The adapter failed to D B88 configure. software 954-135 Description: The device failed to D 954 configure. B88 software 954-136 Description: The certify operation D 954 failed. 954-137 D 954 Description: Unit attention condition has occurred on the Send Diagnostic B88 command. D50 955-098 Description: Disk drive indicates an J 955 error. 955-099 Description: Disk drive not found. J 955 B88 955-102 Description: A media error was D 955 encountered. 141 955-104 Description: The motor failed to D 955 restart. 141 Action: For devices installed in a drawer/deskside unit, use the drawer/deskside unit documentation. Refer to "Drawer/Deskside Unit Documentation" under Hints in Chapter 1. For other locations, go to MAP 0210. If the electronics card has been exchanged, exchange the adapter first. If the drawer/deskside unit documentation does not isolate the problem, go to MAP 0210. 955-105 Description: The disk drive did not D 955 become ready. 141 955-106 Description: The electronics card D 955 failed. 141 955-108 Description: The bus test failed. D 955 955-110 Description: The media format is D 955 corrupted. 141 955-112 Description: The diagnostic test D 955 failed. 141 955-114 Description: An unrecoverable hardware D 955 error. 141 955-116 Description: A protocol error. D Action: Check the levels of the device, adapter, diagnostic software, and application software to be sure they are all compatible. If you do not find a problem, call your support person. 955-118 Description: A SCSI command timeout. D 955 B88 955-120 Description: A SCSI busy or command D 955 error. B88 955-122 Description: A SCSI reservation D 955 conflict error. 955-124 Description: A SCSI check condition D 955 error. B88 955-126 Description: A software error was D 955 caused by a hardware failure. B88 955-128 Description: The error log analysis G 955 indicates a hardware failure. 141 955-129 G D50 Description: Error log analysis indicates a SCSI bus problem. 955 B88 software 955-130 G 955 Description: Error log analysis indicates a problem reported by the disk drive's self monitoring function. 955-132 Description: A disk drive hardware D 955 error occurred. 955-134 Description: The adapter failed to D B88 configure. software 955-135 Description: The device failed to D 955 configure. B88 software 955-136 Description: The certify operation D 955 failed. 141 955-137 D 955 Description: Unit attention condition has occurred on the Send Diagnostic B88 command. D50 956-102 D 956 Description: An unrecoverable media error. 956-104 D 956 Description: The motor failed to restart. 956-105 D 956 Description: The drive did not become ready. 956-106 D 956 Description: The electronics card test failed. 956-108 D 956 Description: The bus test failed. 956-110 D 956 Description: The media format is corrupted. 956-112 D 956 Description: The diagnostic test failed. 956-114 D 956 Description: An unrecoverable hardware error. 956-116 D Description: A protocol error. Action: Check the levels of the device, adapter, diagnostic software, and application software to be sure they are all compatible. If you do not find a problem, call your support person. 956-117 D 956 Description: A write protect error occurred. 956-118 D 956 Description: A SCSI command time-out. B88 956-120 D 956 Description: A SCSI busy or command error. 956-122 D 956 Description: A SCSI reservation conflict error. 956-124 D 956 Description: A SCSI check condition error. 956-126 D 956 Description: A software error was caused by a hardware failure. B88 956-128 G 956 Description: The error log analysis indicates a hardware failure. 956-130 G 956 Description: The error log analysis indicates a hardware failure. B88 956-132 D 956 Description: A disk drive hardware error occurred. 956-134 D B88 Description: The adapter failed to configure. software 956-136 D 956 Description: The certify operation failed. 959-098 Description: Disk drive indicates an J 959 error. 959-099 Description: Disk drive not found. J 959 B88 959-102 Description: Non-recoverable medium D 959 error. 959-104 Description: Motor failed to restart. D 959 959-105 Description: The drive did not become D 959 ready. 959-106 Description: Electronics card failure. D 959 959-108 Description: Bus failure. D 959 959-110 Description: The media format is D 959 corrupted. 959-112 Description: Diagnostic failure. D 959 959-114 Description: Non-recoverable hardware D 959 error. 959-116 Description: A protocol error was D detected. Action: Check the levels of the device, adapter, diagnostic and application software, and ensure they are all compatible. If you do not find a problem, call your support person. 959-117 Description: Write protect error. D 959 959-118 Description: SCSI command timeout. D 959 B88 959-120 Description: SCSI busy/command error. D 959 959-122 Description: SCSI reservation conflict D 959 error. 959-124 Description: SCSI check condition D 959 error. 959-126 D 959 Description: Software error caused by hardware failure. B88 959-128 G 959 Description: Error log analysis indicates hardware failure. 959-129 G D50 Description: Error log analysis indicates a SCSI bus problem. 959 B88 software 959-130 G 959 Description: Error log analysis indicates a problem reported by the disk drive's self monitoring function. 959-134 Description: The adapter failed to D B88 configure. software 959-135 Description: The device failed to D 959 configure. B88 software 959-136 Description: The certify operation D 959 failed. 959-137 D 959 Description: Unit attention condition has occurred on the Send Diagnostic B88 command. D50 960-102 D 960 Description: An unrecoverable media error. 960-104 D 960 Description: The motor failed to restart. 960-105 D 960 Description: The drive did not become ready. 960-106 D 960 Description: The electronics card test failed. 960-108 D 960 Description: The bus test failed. 960-110 D 960 Description: The media format is corrupted. 960-112 D 960 Description: The diagnostic test failed. 960-114 D 960 Description: An unrecoverable hardware error. 960-116 D Description: A protocol error. Action: Check the levels of the device, adapter, diagnostic software, and application software to be sure they are all compatible. If you do not find a problem, call your support person. 960-117 D 960 Description: A write protect error occurred. 960-118 D 960 Description: A SCSI command time-out. B88 960-120 D 960 Description: A SCSI busy or command error. 960-122 D 960 Description: A SCSI reservation conflict error. 960-124 D 960 Description: A SCSI check condition error. 960-126 D 960 Description: A software error was caused by a hardware failure. B88 960-128 G 960 Description: The error log analysis indicates a hardware failure. 960-129 G D50 Description: Error log analysis indicates a SCSI bus problem. 960 B88 software 960-130 G 960 Description: Error log analysis indicates a problem reported by the disk drive's self monitoring function. 960-132 D 960 Description: A disk drive hardware error occurred. 960-134 D B88 Description: The adapter failed to configure. software 960-135 D 960 Description: The device failed to configure. B88 software 960-136 D 960 Description: The certify operation failed. 960-137 D 960 Description: Unit attention condition has occurred on the Send Diagnostic B88 command. D50 964-098 J 964 Description: Tape drive indicates an error. 964-099 J 964 Description: Tape drive not found. B88 964-101 Description: Timeout while attempting D 964 to communicate with SCSI device. Description: The SCSI device indicates 964-102 D 964 busy. 964-103 Description: The SCSI device indicates D 964 a reservation conflict. 964-104 Description: The SCSI device indicates D 964 a check condition. 964-105 Description: An error is detected in D 964 request sense data. 964-107 Description: Sense data from the SCSI D 964 drive has unexpected data. 964-110 Description: The Reserve command D 964 failed. 964-111 Description: Invalid condition from the D 964 drive after a reserve. 964-112 D 964 Description: The write protect sensor test failed. 964-113 D 964 Description: Invalid condition from drive after a request sense. 964-114 D 964 Description: Timeout while attempting to communicate with the SCSI device. 964-120 D 964 Description: The Inquiry command failed. 964-130 D 964 Description: The Load command failed. media 964-134 Description: The adapter failed to D B88 configure. software 964-135 Description: The Unload command failed. D 964 media 964-140 Description: The Mode Select command D 964 failed. 964-150 Description: The Test Unit Ready D 964 command failed. media 964-160 Description: The Send Diagnostic D 964 command failed. media 964-161 Description: Invalid condition from the D 964 drive after a reserve. B88 964-163 Description: Invalid condition from the D 964 drive after a request sense. B88 964-164 Description: Timeout while attempting D 964 to communicate with the SCSI device. B88 Description: Write, Read and Compare 964-165 D 964 Test failed. B88 276 964-166 Description: Unable to configure the D 964 device. B88 software 964-167 Description: An unexpected SCSI error D 964 occurred. B88 964-168 Description: The adapter failed to D B88 configure. software 964-169 Description: The send diagnostic D 964 command failed. media 964-170 Description: The Read, Write and D 964 Compare test failed. B88 media 964-180 Description: The Load command failed. D 964 media 964-185 Description: The Unload command failed. D 964 media 964-190 Description: The Mode Select command D 964 failed. 964-200 Description: The Test Unit Ready D 964 command failed. media 964-201 Description: Error diagnosed from error G 964 log analysis. B88 964-210 Description: The device configuration D 964 failed. B88 964-211 Description: The device open failed. D 964 B88 964-220 Description: The Release command D 964 failed. 964-230 Description: The Request Sense command D 964 failed. 964-240 Description: The Openx command failed. D 964 964-260 Description: The device configuration D 964 failed. 964-261 Description: The device open failed. D 964 964-300 Description: The device configuration D 964 failed. software 964-310 Description: SCSI adapter configuration D B88 failed. 964 software 964-320 Description: Error log analysis G 964 indicates a failure. media 964-411 Description: A reservation conflict to D 964 occurred. 964-423 B88 software 964-511 Description: The drive returned bad or to D 964 non-extended sense data. 964-523 B88 964-611 Description: An adapter or bus I/O to D 964 error occurred. 964-623 B88 software 964-711 Description: A device timeout error to D 964 occurred. 964-723 B88 software 966-101 D 966 Error in non-interactive tests. 966-103 D 966 The test pattern failed. 966-201 D 966 Description: Error in non-interactive tests on card 190 966-203 D 996 Description: The test pattern failed. 190 966-205 D 966 Description: Test pattern failed 190 966-207 D 966 Description: Test pattern failed 190 966-208 D 190 Description: Error in non-interactive test on card 966-209 D Description: Test pattern failed 190 966-211 D Test pattern failed 190 966-213 D Test pattern failed 190 966-304 D E22 Video error in interactive test 725 966 966-306 D E23 Audio error in interactive test 725 966 966-310 D E22 Video error in interactive test 725 966-312 D E23 Audio error in interactive test 725 966-400 D 152 Error in non-interactive tests 190 E24 166 966-402 D 190 Test pattern failed E23 E22 968-102 D 968 Description: An unrecoverable media error. 968-104 D 968 Description: The motor failed to restart. 968-105 D 968 Description: The drive did not become ready. 968-106 D 968 Description: The electronics card test failed. 968-108 D 968 Description: The bus test failed. 968-110 D 968 Description: The media format is corrupted. 968-112 D 968 Description: The diagnostic test failed. 968-114 D 968 Description: An unrecoverable hardware error. 968-116 D Description: A protocol error. Action: Check the levels of the device, adapter, diagnostic software, and application software to be sure they are all compatible. If you do not find a problem, call your support person. 968-117 D 968 Description: A write protect error occurred. 968-118 D 968 Description: A SCSI command time-out. B88 968-120 D 968 Description: A SCSI busy or command error. 968-122 D 968 Description: A SCSI reservation conflict error. 968-124 D 968 Description: A SCSI check condition error. 968-126 D 968 Description: A software error was caused by a hardware failure. B88 968-128 G 968 Description: The error log analysis indicates a hardware failure. 968-129 G D50 Description: Error log analysis indicates a SCSI bus problem. 968 B88 software 968-130 G 968 Description: Error log analysis indicates a problem reported by the disk drive's self monitoring function. 968-132 D 968 Description: A disk drive hardware error occurred. 968-134 D B88 Description: The adapter failed to configure. software 968-135 D 968 Description: The device failed to configure. B88 software 968-136 D 968 Description: The certify operation failed. 968-137 D 968 Description: Unit attention condition has occurred on the Send Diagnostic B88 command. D50 969-110 G D67 Description: Residual Data Analysis indicates memory error. Action: Use Chapter 14. "MAP 0240: Memory Problem Resolution". 969-111 G D83 Description: Residual Data Analysis indicates memory error. Action: Use Chapter 14. "MAP 0240: Memory Problem Resolution". 969-120 G D68 Description: Residual Data Analysis indicates memory error. Action: Use Chapter 14. "MAP 0240: Memory Problem Resolution". 969-121 G D84 Description: Residual Data Analysis indicates memory error. Action: Use Chapter 14. "MAP 0240: Memory Problem Resolution". 969-130 G D69 Description: Residual Data Analysis indicates memory error. Action: Use Chapter 14. "MAP 0240: Memory Problem Resolution". 969-131 G D85 Description: Residual Data Analysis indicates memory error. Action: Use Chapter 14. "MAP 0240: Memory Problem Resolution". 969-140 G D70 Description: Residual Data Analysis indicates memory error. Action: Use Chapter 14. "MAP 0240: Memory Problem Resolution". 969-141 G D86 Description: Residual Data Analysis indicates memory error. Action: Use Chapter 14. "MAP 0240: Memory Problem Resolution". 969-150 G E11 Description: Residual Data Analysis indicates memory error. Action: Use Chapter 14. "MAP 0240: Memory Problem Resolution". 969-151 G E14 Description: Residual Data Analysis indicates memory error. Action: Use Chapter 14. "MAP 0240: Memory Problem Resolution". 969-206 G D72 Description: Residual Data Analysis indicates memory error. Action: Use Chapter 14. "MAP 0240: Memory Problem Resolution". 969-208 G D73 Description: Residual Data Analysis indicates memory error. Action: Use Chapter 14. "MAP 0240: Memory Problem Resolution". 969-210 G D71 Description: Residual Data Analysis indicates memory error. Action: Use Chapter 14. "MAP 0240: Memory Problem Resolution". 969-211 G D87 Description: Residual Data Analysis indicates memory error. Action: Use Chapter 14. "MAP 0240: Memory Problem Resolution". 969-212 G E12 Description: Residual Data Analysis indicates memory error. 969-220 G D72 Description: Residual Data Analysis indicates memory error. Action: Use Chapter 14. "MAP 0240: Memory Problem Resolution". 969-221 G D88 Description: Residual Data Analysis indicates memory error. Action: Use Chapter 14. "MAP 0240: Memory Problem Resolution". 969-230 G D73 Description: Residual Data Analysis indicates memory error. Action: Use Chapter 14. "MAP 0240: Memory Problem Resolution". 969-231 G D89 Description: Residual Data Analysis indicates memory error. Action: Use Chapter 14. "MAP 0240: Memory Problem Resolution". 969-240 G D74 Description: Residual Data Analysis indicates memory error. Action: Use Chapter 14. "MAP 0240: Memory Problem Resolution". 969-241 G D90 Description: Residual Data Analysis indicates memory error. Action: Use Chapter 14. "MAP 0240: Memory Problem Resolution". 969-250 G E12 Description: Residual Data Analysis indicates memory error. Action: Use Chapter 14. "MAP 0240: Memory Problem Resolution". 969-251 G E15 Description: Residual Data Analysis indicates memory error. Action: Use Chapter 14. "MAP 0240: Memory Problem Resolution". 969-310 G D75 Description: Residual Data Analysis indicates memory error. Action: Use Chapter 14. "MAP 0240: Memory Problem Resolution". 969-311 G D91 Description: Residual Data Analysis indicates memory error. Action: Use Chapter 14. "MAP 0240: Memory Problem Resolution". 969-320 G D76 Description: Residual Data Analysis indicates memory error. Action: Use Chapter 14. "MAP 0240: Memory Problem Resolution". 969-321 G D92 Description: Residual Data Analysis indicates memory error. Action: Use Chapter 14. "MAP 0240: Memory Problem Resolution". 969-330 G D77 Description: Residual Data Analysis indicates memory error. Action: Use Chapter 14. "MAP 0240: Memory Problem Resolution". 969-331 G D93 Description: Residual Data Analysis indicates memory error. Action: Use Chapter 14. "MAP 0240: Memory Problem Resolution". 969-340 G D78 Description: Residual Data Analysis indicates memory error. Action: Use Chapter 14. "MAP 0240: Memory Problem Resolution". 969-341 G D94 Description: Residual Data Analysis indicates memory error. Action: Use Chapter 14. "MAP 0240: Memory Problem Resolution". 969-350 G E13 Description: Residual Data Analysis indicates memory error. Action: Use Chapter 14. "MAP 0240: Memory Problem Resolution". 969-351 G E16 Description: Residual Data Analysis indicates memory error. Action: Use Chapter 14. "MAP 0240: Memory Problem Resolution". 969-600 G Description: Residual Data Analysis indicates memory error or unsupported memory. Action: Examine the memory modules and determine if they are supported types. If the modules are supported, then replace the appropriate memory module(s). Use Chapter 14. "MAP 0240: Memory Problem Resolution". 969-701 D 814 Description: NVRAM test failed 969-702 D 151 Description: Time of Day Battery test failed 969-703 D 817 Description: Time of Day Chip test failed 969-800 G 221 Description: Memory problems indicate System Planar failure 969-900 G D01 Description: L2 cache test failed 970-098 J 970 Description: Tape drive indicates an error. 970-099 J 970 Description: Tape drive not found. B88 970-101 D 970 Description: Timeout while attempting to communicate with SCSI device. 970-102 D 970 Description: The SCSI device indicates busy. 970-103 D 970 Description: The SCSI device indicates a reservation conflict. 970-104 D 970 Description: The SCSI device indicates a check condition. 970-105 D 970 Description: An error is detected in request sense data. 970-107 D 970 Description: Sense data from the SCSI drive has unexpected data. 970-110 D 970 Description: The Reserve command failed. 970-111 D 970 Description: Invalid condition from the drive after a reserve. 970-112 D 970 Description: The write protect sensor test failed. 970-113 D 970 Description: Invalid condition from drive after a request sense. 970-114 D 970 Description: Timeout while attempting to communicate with the SCSI device. 970-120 D 970 Description: The Inquiry command failed. 970-130 D 970 Description: The Load command failed. media 970-134 D B88 Description: The adapter failed to configure. software 970-135 D 970 Description: The Unload command failed. media 970-140 D 970 Description: The Mode Select command failed. 970-150 D 970 Description: The Test Unit Ready command failed. media 970-160 D 970 Description: The Send Diagnostic command failed. media 970-161 D 970 Description: Invalid condition from the drive after a reserve. B88 970-163 D 970 Description: Invalid condition from the drive after a request sense. B88 970-164 D 970 Description: Timeout while attempting to communicate with the SCSI device. B88 970-165 D 970 Description: Write, Read and Compare Test failed. B88 276 970-166 D 970 Description: Unable to configure the device. B88 software 970-167 D 970 Description: An unexpected SCSI error occurred. B88 970-168 D B88 Description: The adapter failed to configure. software 970-169 D 970 Description: The send diagnostic command failed. media 970-170 D 970 Description: The Read, Write and Compare test failed. B88 970-180 D 970 Description: The Load command failed. media 970-185 D 970 Description: The Unload command failed. media 970-190 D 970 Description: The Mode Select command failed. 970-200 D 970 Description: The Test Unit Ready command failed. media 970-201 G 970 Description: Error diagnosed from error log analysis. B88 970-210 D 970 Description: The device configuration failed. B88 970-211 D 970 Description: The device open failed. B88 970-220 D 970 Description: The Release command failed. 970-230 D 970 Description: The Request Sense command failed. 970-240 D 970 Description: The Openx command failed. 970-260 D 970 Description: The device configuration failed. 970-261 D 970 Description: The device open failed. 970-300 D 970 Description: The device configuration failed. software 970-310 D B88 Description: SCSI adapter configuration failed. 970 software 970-320 G 970 Description: Error log analysis indicates a failure. media 970-411 D 970 Description: A reservation conflict occurred. to B88 970-423 software 970-511 D 970 Description: The drive returned bad or non-extended sense data. to B88 970-523 970-611 D 970 Description: An adapter or bus I/O error occurred. to B88 970-623 software 970-711 D 970 Description: A device timeout error occurred. to B88 970-723 software 971-098 J 971 Description: Tape drive indicates an error. 971-099 J 971 Description: Tape drive not found. B88 971-101 D 971 Description: Timeout while attempting to communicate with SCSI device. 971-102 D 971 Description: The SCSI device indicates busy. 971-103 D 971 Description: The SCSI device is indicating a reservation conflict. 971-104 D 971 Description: The SCSI device indicates a check condition. 971-105 D 971 Description: Sense data from the SCSI device shows an error. 971-107 D 971 Description: The SCSI drive returned unexpected sense data. 971-110 D 971 Description: The Reserve command failed. 971-111 D 971 Description: Invalid condition from the drive after a reserve. 971-112 D 971 Description: The write protect sensor test failed. 971-113 D 971 Description: Invalid condition from the drive after a request sense. 971-114 D 971 Description: Timeout while attempting to communicate with the SCSI device. 971-120 D 971 Description: The Inquiry command failed. 971-130 D 971 Description: The Load command failed. media 971-135 D 971 Description: The Unload command failed. media 971-140 D 971 Description: The Mode Select command failed. 971-150 D 971 Description: The Test Unit Ready command failed. media 971-160 D 971 Description: The Send Diagnostic command failed. media 971-161 D 971 Description: Invalid condition from the drive after a reserve. B88 971-163 D 971 Description: Invalid condition from the drive after a request sense. B88 971-164 D 971 Description: Timeout while attempting to communicate with the SCSI device. B88 971-165 D 971 Description: Write, Read and Compare Test failed. B88 276 971-166 D 971 Description: Unable to configure the device. B88 software 971-167 D 971 Description: An unexpected SCSI error occurred. B88 971-168 D B88 Description: The adapter failed to configure. software 971-169 D 971 Description: The Send Diagnostic command failed. media 971-170 D 971 Description: The Read, Write and Compare test failed. B88 media 971-180 D 971 Description: The Load command failed. media 971-185 D 971 Description: The Unload command failed. media 971-190 D 971 Description: The Mode Select command failed. 971-200 D 971 Description: The Test Unit Ready command failed. media 971-201 G 971 Description: An error is diagnosed from the error log analysis. B88 971-210 D 971 Description: The device configuration failed. B88 971-211 D 971 Description: The device open test failed. B88 971-220 D 971 Description: The Release command failed. 971-230 D 971 Description: The Request Sense command failed. 971-240 D 971 Description: The Openx command failed. 971-260 D 971 Description: The device configuration failed. 971-261 D 971 Description: The device open test failed. 971-300 D 971 Description: The device configuration failed. software 971-310 D B88 Description: SCSI adapter configuration failed. 971 software 971-320 G 971 Description: Error log analysis indicates a failure. media 971-411 D 971 Description: A reservation conflict occurred. to B88 971-423 software 971-511 D 971 Description: The drive returned bad or non-extended sense data. to B88 971-523 971-611 D 971 Description: An adapter or bus I/O error occurred. to software 971-623 971-711 D 971 Description: A device timeout error occurred. to B88 971-723 software 972-101 D 972 Description: Timeout while attempting to communicate with SCSI device. 972-102 D 972 Description: The SCSI device indicates busy. 972-103 D 972 Description: The SCSI device indicates a reservation conflict. 972-104 D 972 Description: The SCSI device indicates a check condition. 972-105 D 972 Description: An error is detected in request sense data. 972-107 D 972 Description: The drive has returned unexpected sense data. 972-110 D 972 Description: The Reserve command failed. 972-111 D 972 Description: Invalid condition from the drive after a reserve. 972-112 D 972 Description: The write protect sensor test failed. 972-113 D 972 Description: Invalid condition from the drive after a request sense. 972-114 D 972 Description: Timeout while attempting to communicate with the SCSI device. 972-120 D 972 Description: The Inquiry command failed. 972-130 D 972 Description: The Load command failed. media 972-135 D 972 Description: The Unload command failed. media 972-140 D 972 Description: The Mode Select command failed. 972-150 D 972 Description: The Test Unit Ready command failed. media 972-160 D 972 Description: The Send Diagnostic command failed. media 972-161 D 972 Description: Invalid condition from the drive after a reserve. B88 972-163 D 972 Description: Invalid condition from the drive after a request sense. B88 972-164 D 972 Description: Timeout while attempting communication with SCSI device. B88 276 972-165 D 972 Description: Write, Read and Compare Test failed. B88 276 972-166 D 972 Description: Unable to configure the device. B88 software 972-167 D 972 Description: An unexpected SCSI error occurred. B88 972-168 D B88 Description: The adapter failed to configure. software 972-169 D 972 Description: The send diagnostic command failed. media 972-170 D 972 Description: The Read, Write and Compare test failed. B88 media 972-180 D 972 Description: The Load command failed. media 972-185 D 972 Description: The Unload command failed. media 972-190 D 972 Description: The Mode Select command failed. 972-200 D 972 Description: The Test Unit Ready command failed. media 972-201 G 972 Description: An error is diagnosed from the error log analysis. B88 972-210 D 972 Description: The device configuration failed. B88 972-211 D 972 Description: The device open test failed. B88 972-220 D 972 Description: The Release command failed. 972-230 D 972 Description: The Request Sense command failed. 972-240 D 972 Description: The Openx command failed. 972-260 D 972 Description: The device configuration test failed. 972-261 D 972 Description: The device open test failed. 972-300 D 972 Description: The device configuration failed. software 972-310 D B88 Description: SCSI adapter configuration failed. 972 software 972-320 G 972 Description: Error log analysis indicates a failure. media 972-411 D 972 Description: A reservation conflict to occurred. 972-423 B88 software 972-511 D 972 Description: The drive returned bad or to non-extended sense data. 972-523 B88 972-611 D 972 Description: An adapter or bus I/O error to occurred. 972-623 B88 software 972-711 D 972 Description: A device timeout error to occurred. 972-723 B88 software 973-110 D 973 Description: The Reserve command failed. 973-120 D 973 Description: The Inquiry command failed. 973-130 D 973 Description: The Load command failed. media 973-135 D 973 Description: The Unload command failed. media 973-140 D 973 Description: The Mode Select command failed. 973-150 D 973 Description: The Test Unit Ready command failed. media 973-160 D 973 Description: The Send Diagnostic command failed. media 973-169 D 973 Description: The send diagnostic command failed. media 973-170 D 973 Description: The Read, Write and Compare test failed. B88 media 973-180 D 973 Description: The Load command failed. media 973-185 D 973 Description: The Unload command failed. media 973-190 D 973 Description: The Mode Select command failed. 973-200 D 973 Description: The Test Unit Ready command failed. media 973-210 D 973 Description: The device configuration failed. B88 973-220 D 973 Description: The Release command failed. 973-230 D 973 Description: The Request Sense command failed. 973-240 D 973 Description: The Openx command failed. 973-300 D 973 Description: The device configuration failed. software 973-310 D B88 Description: SCSI adapter configuration failed. 973 software 973-320 G 973 Description: Error log analysis indicates a failure. media 973-411 D 973 Description: A reservation conflict to occurred. 973-423 B88 software 973-511 D 973 Description: The drive returned bad or to non-extended sense data. 973-523 B88 973-611 D 973 Description: An adapter or bus I/O error to occurred. 973-623 B88 software 973-711 D 973 Description: A device timeout error to occurred. 973-723 B88 software 974-111 D 974 Description: Unable to reserve device. B88 974-112 D 974 Description: Unable to do configuration. B88 974-113 D 974 Description: Unable to open the device driver. B88 974-121 D 974 Description: The CD-ROM drive indicates an error. 974-122 D 974 Description: The CD-ROM drive indicates an error. 974-123 D 974 Description: The CD-ROM drive indicates an error. 974-125 D 974 Description: The CD-ROM drive indicates an error. B88 974-126 D 974 Description: The CD-ROM drive indicates an error. 974-127 D 974 Description: The CD-ROM drive indicates an error. 974-128 D 974 Description: The CD-ROM drive indicates an error. 974-129 D 974 Description: The CD-ROM drive indicates an error. 974-150 D Media Description: A media error was detected. 974-151 D 974 Description: A command timeout was detected. D88 974-152 D 974 Description: A command reservation conflict was detected. 974-162 D 974 Description: The CD-ROM drive indicates an error. 974-171 D 974 Description: Unable to reserve device. 974-172 D 974 Description: Unable to do configuration. 974-173 D 974 Description: Unable to open device driver. 974-175 D 974 Description: The CD-ROM drive indicates an error. 974-198 D 974 Description: Undefined error detected. B88 974-199 D 974 Description: Undefined error detected. 974-211 D 974 Description: The LED test failed. 974-281 D 974 Description: No tone during audio test. 974-301 G 974 Description: Errors found during ELA. 974-302 G 974 Description: Errors log analysis indicates hardware failure. B88 981-102 Description: An unrecoverable media D 981 error. 981-104 Description: The motor failed to D 981 restart. 981-105 Description: The drive did not become D 981 ready. 981-106 Description: The electronics card test D 981 failed. 981-108 Description: The bus test failed. D 981 981-110 Description: The media format is D 981 corrupted. 981-112 Description: The diagnostic test D 981 failed. 981-114 Description: An unrecoverable hardware D 981 error. 981-116 Description: A protocol error. D Action: Check the levels of the device, adapter, diagnostic software, and application software to be sure they are all compatible. If you do not find a problem, call your support person. 981-117 Description: A write protect error D 981 occurred. 981-118 Description: A SCSI command time-out. D 981 B88 981-120 Description: A SCSI busy or command D 981 error. 981-122 Description: A SCSI reservation D 981 conflict error. 981-124 Description: A SCSI check condition D 981 error. 981-126 Description: A software error was D 981 caused by a hardware failure. B88 981-128 Description: The error log analysis G 981 indicates a hardware failure. 981-129 G D50 Description: Error log analysis indicates a SCSI bus problem. 981 B88 software 981-130 G 981 Description: Error log analysis indicates a problem reported by the disk drive's self monitoring function. 981-132 Description: A disk drive hardware D 981 error occurred. 981-134 Description: The adapter failed to D B88 configure. software 981-136 Description: The certify operation D 981 failed. 981-137 D 981 Description: Unit attention condition has occurred on the Send Diagnostic B88 command. D50 984-102 D 984 Description: An unrecoverable media error. 984-104 D 984 Description: The motor failed to restart. 984-105 D 984 Description: The drive did not become ready. 984-106 D 984 Description: The electronics card test failed. 984-108 D 984 Description: The bus test failed. 984-110 D 984 Description: The media format is corrupted. 984-112 D 984 Description: The diagnostic test failed. 984-114 D 984 Description: An unrecoverable hardware error. 984-116 D Description: A protocol error. Action: Check the levels of the device, adapter, diagnostic software, and application software to be sure they are all compatible. If you do not find a problem, call your support person. 984-117 D 984 Description: A write protect error occurred. 984-118 D 984 Description: A SCSI command time-out. B88 984-120 D 984 Description: A SCSI busy or command error. 984-122 D 984 Description: A SCSI reservation conflict error. 984-124 D 984 Description: A SCSI check condition error. 984-126 D 984 Description: A software error was caused by a hardware failure. B88 984-128 G 984 Description: The error log analysis indicates a hardware failure. 984-129 G D50 Description: Error log analysis indicates a SCSI bus problem. 984 B88 software 984-130 G 984 Description: Error log analysis indicates a problem reported by the disk drive's self monitoring function. 984-132 D 984 Description: A disk drive hardware error occurred. 984-134 D B88 Description: The adapter failed to configure. software 984-137 D 984 Description: Unit attention condition has occurred on the Send Diagnostic B88 command. D50 986-102 D 986 Description: An unrecoverable media error. 986-104 D 986 Description: The motor failed to restart. 986-105 D 986 Description: The drive did not become ready. 986-106 D 986 Description: The electronics card test failed. 986-108 D 986 Description: The bus test failed. 986-110 D 986 Description: The media format is corrupted. 986-112 D 986 Description: The diagnostic test failed. 986-114 D 986 Description: An unrecoverable hardware error. 986-116 D Description: A protocol error. Action: Check the levels of the device, adapter, diagnostic software, and application software to be sure they are all compatible. If you do not find a problem, call your support person. 986-117 D 986 Description: A write protect error occurred. 986-118 D 986 Description: A SCSI command time-out. B88 986-120 D 986 Description: A SCSI busy or command error. 986-122 D 986 Description: A SCSI reservation conflict error. 986-124 D 986 Description: A SCSI check condition error. 986-126 D 986 Description: A software error was caused by a hardware failure. B88 986-128 G 986 Description: The error log analysis indicates a hardware failure. 986-129 G D50 Description: Error log analysis indicates a SCSI bus problem. 986 B88 software 986-130 G 986 Description: Error log analysis indicates a problem reported by the disk drive's self monitoring function. 986-132 D 986 Description: A disk drive hardware error occurred. 986-134 D B88 Description: The adapter failed to configure. software 986-136 D 986 Description: The certify operation failed. C11 986-137 D 986 Description: Unit attention condition has occurred on the Send Diagnostic B88 command. D50 987-111 D 987 Description: Unable to reserve device. B88 987-112 D 987 Description: Unable to do configuration. B88 987-113 D 987 Description: Unable to open the device driver. B88 987-121 D 987 Description: The CD-ROM drive indicates an error. 987-122 D 987 Description: The CD-ROM drive indicates an error. 987-123 D 987 Description: The CD-ROM drive indicates an error. 987-125 D 987 Description: The CD-ROM drive indicates an error. 987-126 D 987 Description: The CD-ROM drive indicates an error. 987-127 D 987 Description: The CD-ROM drive indicates an error. 987-128 D 987 Description: The CD-ROM drive indicates an error. 987-129 D 987 Description: The CD-ROM drive indicates an error. 987-150 D Media Description: A media error was detected. 987 987-151 D 987 Description: A command timeout was detected. B88 987-152 D 987 Description: A command reservation conflict was detected. 987-162 D 987 Description: The CD-ROM drive indicates an error. 987-171 D 987 Description: Unable to reserve device. 987-172 D 987 Description: Unable to do configuration. 987-173 D 987 Description: Unable to open device driver. 987-175 D 987 Description: The CD-ROM drive indicates an error. 987-198 D 987 Description: Undefined error detected. B88 987-199 D 987 Description: Undefined error detected. 987-211 D 987 Description: The LED test failed. 987-281 D 987 Description: No tone during audio test. 987-301 G 987 Description: Errors found during ELA. 987-302 G 987 Description: Errors found during ELA. B88 989-102 D 989 Description: An unrecoverable media error 989-104 D 989 Description: The motor failed to restart. 989-105 D 989 Description: The drive did not become ready. 989-106 D 989 Description: The electronics card test failed. 989-108 D 989 Description: The bus test failed. 989-110 D 989 Description: The media format is corrupted. 989-112 D 989 Description: The diagnostic test failed. 989-114 D 989 Description: A non-recoverable hardware error 989-116 D Description: A protocol error. Action: Check the levels of the device, adapter, diagnostic software, and application software to be sure they are all compatible. If you do not find a problem, call your support person. 989-117 D 989 Description: A write protect error occurred. 989-118 D 989 Description: A SCSI command time-out. B88 989-120 D 989 Description: A SCSI busy or command error. 989-122 D 989 Description: A SCSI reservation conflict error 989-124 D 989 Description: A SCSI check condition error 989-126 D 989 Description: A software error was caused by a hardware failure. B88 989-128 G 989 Description: The error log analysis indicates a hardware failure. 989-129 G D50 Description: Error log analysis indicates a SCSI bus problem. 989 B88 software 989-130 G 989 Description: Error log analysis indicates a problem reported by the disk drive's self monitoring function. 989-132 Description: A disk drive hardware D 989 error occurred. 989-134 Description: The adapter failed to D B88 configure. software 989-135 Description: The device failed to D 989 configure. B88 software 989-136 Description: The certify operation D 989 failed. 989-137 D 989 Description: Unit attention condition has occurred on the Send Diagnostic B88 command. D50 990-102 D 990 Description: An unrecoverable media error. 990-104 D 990 Description: The motor failed to restart. 990-105 D 990 Description: The drive did not become ready. 990-106 D 990 Description: The electronics card test failed. 990-108 D 990 Description: The bus test failed. 990-110 D 990 Description: The media format is corrupted. 990-112 D 990 Description: The diagnostic test failed. 990-114 D 990 Description: An unrecoverable hardware error. 990-116 D Description: A protocol error. Action: Check the levels of the device, adapter, diagnostic software, and application software to be sure they are all compatible. If you do not find a problem, call your support person. 990-117 D 990 Description: A write protect error occurred. 990-118 D 990 Description: A SCSI command time-out. B88 990-120 D 990 Description: A SCSI busy or command error. 990-122 D 990 Description: A SCSI reservation conflict error. 990-124 D 990 Description: A SCSI check condition error. 990-126 D 990 Description: A software error was caused by a hardware failure. B88 990-128 G 990 Description: The error log analysis indicates a hardware failure. 990-129 G D50 Description: Error log analysis indicates a SCSI bus problem. 990 B88 software 990-130 G 990 Description: Error log analysis indicates a problem reported by the disk drive's self monitoring function. 990-132 D 990 Description: A disk drive hardware error occurred. 990-134 D B88 Description: The adapter failed to configure. software 990-136 D 990 Description: The certify operation failed. 990-137 D 990 Description: Unit attention condition has occurred on the Send Diagnostic B88 command. D50 991-101 D 991 Description: Timeout while attempting to communicate with SCSI device. 991-102 D 991 Description: The SCSI device indicates busy. 991-103 D 991 Description: The SCSI device is indicating a reservation conflict. 991-104 D 991 Description: The SCSI device indicates a check condition. 991-105 D 991 Description: Sense data from the SCSI device shows an error. 991-107 D 991 Description: The SCSI drive returned unexpected sense data. 991-110 D 991 Description: The Reserve command failed. 991-111 D 991 Description: Invalid condition from the drive after a reserve. 991-112 D 991 Description: The write protect sensor test failed. 991-113 D 991 Description: Invalid condition from the drive after a request sense. 991-114 D 991 Description: Timeout while attempting to communicate with the SCSI device. 991-120 D 991 Description: The Inquiry command failed. 991-130 D 991 Description: The Load command failed. media 991-135 D 991 Description: The Unload command failed. media 991-140 D 991 Description: The Mode Select command failed. 991-150 D 991 Description: The Test Unit Ready command failed. media 991-160 D 991 Description: The Send Diagnostic command failed. media 991-161 D 991 Description: Invalid condition from the drive after a reserve. B88 991-163 D 991 Description: Invalid condition from the drive after a request sense. B88 991-164 D 991 Description: Timeout while attempting to communicate with the SCSI device. B88 991-165 D 991 Description: Write, Read and Compare Test failed. B88 276 991-166 D 991 Description: The device failed to configure. B88 software 991-167 D 991 Description: An unexpected SCSI error occurred. B88 991-168 D B88 Description: The adapter failed to configure. software 991-169 D 991 Description: The send diagnostic command failed. media 991-170 D 991 Description: The Read, Write and Compare test failed. B88 media 991-180 D 991 Description: The Load command failed. media 991-185 D 991 Description: The Unload command failed. media 991-190 D 991 Description: The Mode Select command failed. 991-200 D 991 Description: The Test Unit Ready command failed. media 991-201 G 991 Description: An error is diagnosed from the error log analysis. B88 991-210 D 991 Description: The device configuration failed. B88 991-211 D 991 Description: The device open test failed. B88 991-220 D 991 Description: The Release command failed. 991-230 D 991 Description: The Request Sense command failed. 991-240 D 991 Description: The Openx command failed. 991-260 D 991 Description: The device configuration failed. 991-261 D 991 Description: The device open test failed. 991-300 D 991 Description: The device configuration failed. software 991-310 D B88 Description: SCSI adapter configuration failed. 991 software 991-320 G 991 Description: Error log analysis indicates a failure. media 991-411 D 991 Description: A reservation conflict to occurred. 991-423 B88 software 991-511 D 991 Description: The drive returned bad or to non-extended sense data. 991-523 B88 991-611 D 991 Description: An adapter or bus I/O error to occurred. 991-623 B88 software 991-711 D 991 Description: A device timeout error to occurred. 991-723 B88 software 994-110 D 994 Description: The Reserve command failed. 994-120 D 994 Description: The Inquiry command failed. 994-130 D 994 Description: The Load command failed. media 994-135 D 994 Description: The Unload command failed. media 994-140 D 994 Description: The Mode Select command failed. 994-150 D 994 Description: The Test Unit Ready command failed. media 994-160 D 994 Description: The Send Diagnostic command failed. media 994-169 D 994 Description: The send diagnostic command failed. media 994-170 D 994 Description: The Read, Write and Compare test failed. B88 media 994-180 D 994 Description: The Load command failed. media 994-185 D 994 Description: The Unload command failed. media 994-190 D 994 Description: The Mode Select command failed. 994-200 D 994 Description: The Test Unit Ready command failed. media 994-210 D 994 Description: The device configuration failed. B88 994-220 D 994 Description: The Release command failed. 994-230 D 994 Description: The Request Sense command failed. 994-240 D 994 Description: The Openx command failed. 994-300 D 994 Description: The device configuration failed. software 994-310 D B88 Description: SCSI adapter configuration failed. 994 software 994-320 G 994 Description: Error log analysis indicates a failure. media 994-411 D 994 Description: A reservation conflict to occurred. 994-423 B88 software 994-511 D 994 Description: The drive returned bad or to non-extended sense data. 994-523 B88 994-611 D 994 Description: An adapter or bus I/O error to occurred. 994-623 B88 software 994-711 D 994 Description: A device timeout error to B88 occurred. 994-723 software 995-110 D 995 Description: The Reserve command failed. 995-120 D 995 Description: The Inquiry command failed. 995-130 D 995 Description: The Load command failed. media 995-135 D 995 Description: The Unload command failed. media 995-140 D 995 Description: The Mode Select command failed. 995-150 D 995 Description: The Test Unit Ready command failed. media 995-160 D 995 Description: The Send Diagnostic command failed. media 995-169 D 995 Description: The send diagnostic command failed. media 995-170 D 995 Description: The Read, Write and Compare test failed. B88 media 995-180 D 995 Description: The Load command failed. media 995-185 D 995 Description: The Unload command failed. media 995-190 D 995 Description: The Mode Select command failed. 995-200 D 995 Description: The Test Unit Ready command failed. media 995-210 D 995 Description: The device configuration failed. B88 995-220 D 995 Description: The Release command failed. 995-230 D 995 Description: The Request Sense command failed. 995-240 D 995 Description: The Openx command failed. 995-300 D 995 Description: The device configuration failed. software 995-310 D B88 Description: SCSI adapter configuration failed. 995 software 995-320 G 995 Description: Error log analysis indicates a failure. media 995-411 D 995 Description: A reservation conflict to occurred. 995-423 B88 software 995-511 D 995 Description: The drive returned bad or to non-extended sense data. 995-523 B88 995-611 D 995 Description: An adapter or bus I/O error to occurred. 995-623 B88 software 995-711 D 995 Description: A device timeout error to occurred. 995-723 B88 software 998-110 D 998 Description: The Reserve command failed. 998-120 D 998 Description: The Inquiry command failed. 998-130 D 998 Description: The Load command failed. media 998-135 D 998 Description: The Unload command failed. media 998-140 D 998 Description: The Mode Select command failed. 998-150 D 998 Description: The Test Unit Ready command failed. media 998-160 D 998 Description: The Send Diagnostic command failed. media 998-169 D 998 Description: The send diagnostic command failed. media 998-170 D 998 Description: The Read, Write and Compare test failed. B88 media 998-180 D 998 Description: The Load command failed. media 998-185 D 998 Description: The Unload command failed. media 998-190 D 998 Description: The Mode Select command failed. 998-200 D 998 Description: The Test Unit Ready command failed. media 998-210 D 998 Description: The device configuration failed. B88 998-220 D 998 Description: The Release command failed. 998-230 D 998 Description: The Request Sense command failed. 998-240 D 995 Description: The Openx command failed. 998-300 D 995 Description: The device configuration failed. software 998-310 D B88 Description: SCSI adapter configuration failed. 995 software 998-320 G 995 Description: Error log analysis indicates a failure. media 998-411 D 998 Description: A reservation conflict to occurred. 998-423 B88 software 998-511 D 998 Description: The drive returned bad or to non-extended sense data. 998-523 B88 998-611 D 998 Description: An adapter or bus I/O error to occurred. 998-623 B88 software 998-711 D 998 Description: A device timeout error to occurred. 998-723 B88 software 999-xxx D 999 Description: A 7137 or 3514 disk array series subsystem problem is indicated. Action: Use 7137 or 3514 documentation. 9CC-1xx G Description: I/O Error on PCI bus. Action: Refer to the Bus SRN to FRU Reference Table in the system unit's service guide. Note: xx represents the last 2 digits of the SRN. 9CC-xxx G xxx Description: I/O Bus Data, Address Parity Error, or Time-out error. 2C9 Note: xxx represents the last 3 digits of the SRN. xxxxxxxx G none Description: Refer to the Error Code to FRU Index in the system unit's service guide. Action: Use the "Error Code to FRU Index" in the service guide. ----------------------- Bottom of file -------------------------------------------------