FFC ( Failing Function Codes ) - See TEXT at the bottom
Failing Machine FRU Description and Notes
Function Type/Model Part
Code Number
110 7016 09G3495 CVME interface card
7235 09G3715 CVME interface card
111 7016 16F0806 Graphics control processor
card
7235 74F3384 Graphics control processor
card
112 7016 53F6536 8-bit pixel memory card
7235 53F6536 8-bit pixel memory card
113 7016 74F3118 Shading processor card
7235 74F3118 Shading processor card
114 7016 88G2965 Drawing processor card
7235
115 7016 53F6538 24-bit pixel memory card
7235
116 7016 39F6807 Cable, ribbon, CVME signal
39F6808 Cable, RGB
7235 74F3102 Cable, ribbon, CVME signal
74F3104 Cable, RGB, internal
117 7016 16F0795 Graphics subsystem, Kanji,
7235 ROM
118 42F6889 MZB1 Z-buffer option card
(24-bit Color Graphics
Upgrade)
119 88G3988 Base graphics card, POWER
Gt4
120 51G9395 Memory Option, POWER Gt4
Field upgrade graphics
card, 8 to 24-bit
51G9225 Cable, two-position
Note: This FRU contains two
cables, one with black
connectors, 51G9224, and
one with brown connectors,
71F0253. If either of the
connectors on the cable
being replaced is brown,
the replacement cable with
the brown connectors must
be used; if neither of the
connectors on the cable
being replaced is brown,
the replacement cable with
the black connectors must
be used.
51G9227 Cable, three-position
Note: This FRU contains two
cables, one with black
connectors, 51G9226, and
one with brown connectors,
71F0254. If either of the
connectors on the cable
being replaced is brown,
the replacement cable with
the brown connectors must
be used; if neither of the
connectors on the cable
being replaced is brown,
the replacement cable with
the black connectors must
be used.
121 5081 Color display, model 16
(1280 x 1024)
122 5081 Color display, model 19
(1280 x 1024)
128 71F1151 MRV2, color graphics video
card
53F3271 Card connector cable, wide
53F3272 Card connector cable,
narrow
130 42F6842 MGE2, color graphics base
card
53F3271 Card connector cable, wide
53F3272 Card connector cable,
narrow
131 Unidentified memory error.
Check all memory modules to
be present and properly
installed. Check all memory
modules to be the same, as
shown in Appendix C. If no
discrepancy is found then
replace the memory modules
in the location called out
by the flashing 888 LEDs.
Note: For 7012/G series,
7013/J series, and 7015/R30
system units refer to FFC
221.
132 The program that just
loaded may be damaged.
133 Unidentified micro-channel
bus problem.
141 45G9502 857M-byte disk enclosure
(assembly)
Note: Exchange the complete
drive assembly whenever
possible. Exchange the
logic card only when the
data on the disk must be
saved. Refer to RETAIN
TDR-064942 for additional
information. Card and frame
assembly 95X2346 must be
used with the 95X2431 disk
enclosure.
142 See note. 670 M-byte SCSI disk
enclosure
Note: Exchange the complete
drive assembly (53F3429)
whenever possible; the disk
enclosure is not available
separately. Exchange the
logic card (6373521) only
when the data on the disk
must be saved.
151 7006 33F8354 Battery, time-of-day,
7008 NVRAM, etc.
7009
7011
7012 G Series 23F0168
7013/J Series 96G4207
7015/R/30/R40/R50
7015/960/970/97B 02G7237 Notes:
/980/98B/990/R24
After replacement of
this FRU the following
must be done by you or
the customer:
o Time and date
must be set.
o Network IP
addresses should
be set (for
Other 23F0168 machines that IPL
from a network).
o The bootlist
should be set to
reflect the
customers
preference for
the IPL devices
(when set
different than
the default
values).
152 7006 65G8077 Power supply
7009 65G8077
Note: When working on a
9076, refer to the
7011 51G8440 following publications:
Scalable POWERparallel
7012 models before 380 91F0844 Systems POWERparallel
Maintenance Information
Volume 2, and Maintenance
7012/380/390/39H 52G4764 Analysis Procedures and
Parts Catalog.
7012 52G4715 Power Supply, -48v DC
7012/397 93H6628 Power Supply
7012/G30/G40 52G4020
7013 Below 570 except 00G2520
55L
7013/55L 52G7533
7013/570 65G7579
7013/580 65G7579
7013/58H/590/59H 8184794
/591/595
7013/595 40H7442 DC/DC converter
7013/J30/J40/J50 39H9222 AC power supply
152 7015/930/950 71F0067 Power supply
7015/970/980 52G1137 Power supply (standard AC)
(cont.)
7015/97B/98B 65G6995 Power supply (standard AC)
88G0053 Power supply (-48V DC)
7015/990 65G6995
7015/R10 88G0131
7015/R20 88G0134
7015/R21 11H8271
7015/R24 65G6995 AC Power supply
152 7015/R30/R40/R50 11H8275 AC Power supply
11H2714 DC Power supply
(cont.)
7016 71F0069 DC Power supply
7018/740/741 00G1249
7018/770/771 65G2946
7030 52G4764
16-Port RAN 40H3611 Power Supply for Remote
Async Node
93H7091 FRU Part Number 51G8139
Power Supply for Remote
Async Node
FRU Part Numbers 93H6549
and 93H6563
153 7013/J01 11H4977 Power Supply
7015 Media Drawer 44F5287 Power supply, SCSI device
9334/010/011 07G4834 drawer/SCSI deskside unit
9334/500/501 07G4833 (110 V)
07G4834 (220 V)
154 43G1796 16M-byte memory card memory
module
157 Base memory card. Refer to
Appendix C. System Memory
Reference for FRU numbers.
158 7013/J01 19H0270 Fan assembly
7015 44F5280 Fan assembly, SCSI device
9334/010/011 44F5280 drawer/SCSI deskside unit
9334/500/501 44F9979
7134
159 6247455 Tablet cursor, Models 21,
22
74F3131 Tablet cursor, 4-button,
6093 Models 11, 12
74F3132 Tablet cursor, 6-button,
6093 Models 11, 12
160 7015 40F9871 Fan, CPU drawer, front
40F9872 Fan, CPU drawer, rear
40F9871 Fan, CPU drawer, power
supply
42F9872 Fan, async drawer, front
59F3688 Fan, async drawer, power
supply
161 7015 59F3876 Battery, battery backup
unit
162 7015 42F6840 Cable, battery backup unit
163 7015 59F3873 Bezel and status panel,
battery backup unit
164 7015 00G3372 Battery backup switching
supply unit
165 7006 31F4287 Operator panel display
7008 43G0056 Operator panel assembly
7009 65G7994
7011 31F4287 Operator panel display
7012/320/32E/32H 00G2121
7012/340/34H/350/ 00G2230
355/360/365/36T/
370/375/37T/380/
390/39H/397
7012/G30/G40 11H3904 Operator panel
7013/520/52H/530/ 00G2126 Operator panel assembly
540/53H/550/560
7013/55L 52G7453
7013/570/580/58H/ 94F3592
590/59H/591/595
7013/J30/J40/J50 19H0205 Operator panel
165 7015/930/950 00G2130 Operator panel, CPU drawer
81F8234 Operator panel, async
(cont.) drawer
7015/970/980/97B 43G1803 Operator panel, CPU
/98B/990 enclosure
43G1803 Operator panel, CPU media
7015/R10/R20/R21 52G1465 enclosure
7015/R24 43G1803 Operator panel
7015/R30/R40/R50 19H0214 Operator panel with keylock
7016 00G2126 Operator panel without
7018/740 00G1968 keylock
7018/741 00G2193
7018/770 52G1446
7018/771 52G1485
7030 00G2230 Operator panel display
166 7006 88G2601 Fan, front
7009 65G7989 Fan, front
7012/320 and 32H 40F9980 Front Fan
(early)
7012/32H (late) 00G2981 Fan, front
through 375 40F9979 Fan, rear
7012/380/390/39H 00G2981 Fan, front
88G3761 Fan, rear
7012/397 11H2694 Fan, CPU high speed
11H3975 Fan, Memory medium speed
7012/G30/G40 11H3884 Fan, CPU/memory/disk fan
(rear fan)
71F1128 Fan, MCA (front fan)
7013/55L 40F9979 Fan, rear
32G1528 Fan, front
166 7013 22F9685 Fan, memory (except 55L,
59H)
(cont.) 00G3277 Fan, disk (except 55L)
65G1877 Fan, supplemental cooling
(except 55L)
7013/591/595/59H 00G3277 Fan, disk
65G1877 Fan, supplemental cooling
42F7434 Fan, power supply
7013/J01 19H0270 Medium Speed Fan Asm. only
19H0221 Expansion Unit Main Fan
Module
7013/J30/J40 19H0219 Fan, Main Fan
19H0270 Medium Speed Fan Asm. only
19H0224 Fan, Disk module
19H0222 Fan, MCA
7013/J50 09H4751 Fan, Main Fan
19H0270 Medium Speed Fan Asm. only
09H4752 High Speed Fan Asm. only
19H0224 Fan, Disk module
19H0222 Fan, MCA
166 7015 40F9871 Fan, CPU drawer (front)
7015/930/950/970/ 40F9871 Fan, CPU drawer, power
(cont.) 97B/980/98B supply
7015/930/950/970/ 40F9872 Fan, CPU drawer (rear),
97B/980/98B async drawer (front)
7015/930/950/970/ 44F5280 Fan, SCSI device drawer
97B/980/98B
7015/930/950/970/ 59F3688 Fan, async drawer, power up
97B/980/98B
7015/990/R24 02G7253 Fan, CPU planar
52G5560 Fan, Media carrier
52G5543 Fan, Disk drive
8185454 Fan, High speed
166 7015/R10/R20 42F7482 Fan, CPU
7015/R10 52G1467 Fan, I/O
(cont.)
7015/R30/R40 11H2655 Fan, CPU
40H7070 Fan Asm. only
11H2686 Fan, CPU
11H2694 Fan, Media, I/O
11H2694 Fan, Power Supply
7015/R50 93H5070 Fan, CPU
93H5822 Fan,CPU
11H2694 Fan, Media, I/O
11H2694 Fan, Power Supply
7016 22F9685 Fan, logic
39F6802 Fan, graphics card cage
70F9846 Fan, disk drive, small
7018 40F9872 Fan, rear
7030 88G3761 Fan, rear
00G2981 Fan, front
167 22F9685 Fan, power supply
7013 models
below 570
7013/570/580/58H/ 42F7434 Fan, power supply
590/591/59H/595
7015/930/950/970/ 40F9871 Fan, CPU drawer power
97B/980/98B supply
7015/930/950/ 40F9872 Fan, power supply
970/97B/980/ 98B/R10/
R20/R21
7015/R24 02G7266 Fan, power supply
7016 22F9685 Fan, power supply
7018 59F4460 Fan, power supply
168 7006 88G2671 Keylock assembly, locking
7009 65G7994 Keylock, Operator panel
assembly
7011 00G2360 Keylock w/keys
7012/320/32H 40F9928 Keylock assembly, locking
71F1354 Keylock assembly,
nonlocking
7012 below 380 81F9038 Keylock assembly, locking
00G1924 Keylock assembly,
nonlocking
7012 models 380 and 88G3961 Keylock assembly, locking
later 00G1924 Keylock assembly,
nonlocking
7012/G30/G40 52G0252 Keylock assembly, locking
52G0254 Keylock assembly,
nonlocking
7013 Below 570 except 31F4215 Keylock
55L
7013/55L/570/580/ 51G9876 Keylock assembly
58H/590/591/595
7013/59H 51G9876 Keylock assembly
168 7013/J30/J40/J50 19H0205 Operator panel assembly
7015/970/980/990 31G9609 Keylock assembly
(cont.)
7015/R10/R20/R21/ R24 52G1485 Keylock, Operator panel
assembly
7015/R30/R40/R50 19H0214 Keylock, Operator panel
assembly
7016 31F4215 Keylock assembly
7018 00G2192 Keylock assembly
7030/3AT/3BT/3CT 88G3961 Keylock assembly, locking
00G1924 Keylock assembly,
nonlocking
169 7006/41T/41W 12H1281 System board
7006/42T/42W 39H8152
7008 43G2429 CPU card
7009/C10 40H5691
7009/C20 40H5693 System board
7011/220 65G7374
7011/230 8184088 System board
7011/250 51G8101 System board (66MHz)
8184306 System board (80MHz)
7012/320/32H 43G0534 System Planar
7012/340/350 51G8812
7012/34H/360/36T/ 00G2793
370/37T
7012/355/365/375 51G9107
7012/380/390/39H 52G4325
7012/397 93H5557
169 7012/G30 35H8832 ELM planar
(cont.) 7012/G40 09J4774
7013 Below 570 except 00G2126
55L
7013/55L 52G7453
7013/570/580/58H/ 94F3592
590/591/59H/595
7013/J30 19H0242 System board
7013/J40 35H8778
7013/J50 09J4816
7015/930/950 00G2130 Operator panel, CPU drawer
81F8234 Operator panel, async
drawer
7015/970/97B/980/ 43G1803 Operator panel, CPU
98B/990 enclosure
7015/R10/R20/R21 52G1485 Operator panel
7015/R24 43G1803 System board
7015/R30/R40/R50 19H0214 Operator panel (with
19G0205 keylock)
Operator panel (without
7016 00G2126 keylock)
169 7018/740 00G1968 Operator panel
7018/741 00G2193
(cont.)
7018/770 52G1446
7018/771 52G1485 System board
7030 52G4325
170 Fan Problem
Note: For type/model and
FRU information, refer to
FFC 166.
171 59F4433 8MB and 16MB SD1 base
memory card
172 70F9973 4MB memory card memory
module
173 59F4581 1MB memory card memory
module
174 59F4582 2MB memory card memory
module
175 59F4581 1MB memory card memory
module
176 70F9973 4MB memory card memory
module
177 70F9976 8MB memory card memory
module
178 81F8926 32MB and 64MB S1.5 and S3
base memory card
179 59F4582 2MB memory card memory
module
180 See System Unit Memory
Combinations in Appendix C.
181 7006 88G2579 Cable, diskette drive
signal
7009 65G8007 Cable, diskette drive
signal
7011/220/230/250 31F4283 Cable, diskette drive
signal
7012 models before 380 40F9925 Cable, diskette drive
signal
7012/380/390/39H/397 51G9521 Cable, diskette drive
signal
7012/G series 11H3757 Diskette drive cable
7013 Below 570 except 00G0976 Cable assembly, SCSI and
55L diskette
7013/55L 52G7449 Cable assembly, diskette
7013/570/580/58H/ 65G7538 Cable Assembly, SCSI and
590/591/59H/595 Diskette
7015/930/950 71F0700 Cable, CPU Drawer Diskette
Signal
181 7015/970/980 02G7306 Cable, CPU Enclosure,
Diskette Signal
(cont.) 7015/97B/98B/990 52G5555 Cable, CPU Media Enclosure,
Diskette Signal
7015/R10/R20/R21 52G1466 Cable, CPU Drawer, Diskette
Signal
7015/R24 52G6136 Cable, CPU Media Enclosure,
Diskette Signal
7015/R30/R40/R50 40H7045 Operator panel
cable/receiver asm
7016 53F3319 Cable, Diskette Drive
Signal
7018 71F0700 Cable, CPU drawer diskette
signal
7030 51G9521 Cable, diskette drive
signal
182 70F9976 8M-byte memory card
memory module
183 7013 Below 570 53F3417 Diskette redrive card
excluding 55L
7015/930/950 53F4172 Diskette redrive card
184 4869/002 15F7993 5.25-inch external
diskette drive, 1.2M-byte,
7012/320/32H 11F8890 Riser card, external
diskette
7013 Below 570 40F9781 Cable, external 5.25-inch
excluding 55L diskette
185 68X5706 X.25 memory DRAM SIP
186 8184299 Multiprotocol interface
card
187 7013/540 59F4583 4M-byte memory card memory
module
188 6247454 Tablet stylus, Models 21,
22
74F3133 Tablet stylus, 6093 Models
11, 12
189 7012/320/32H 81F8900 Direct Bus Attach Riser
Card
7012 Below 380 00G2721 Extender, SCSI bus
190 00G0959 Cable, SCSI (Increased
Availability)
7006 88G2577 Cable, internal SCSI disk
drive
7009 65G8006 Cable, internal SCSI disk
drive
7011/220/230/250 31F4284 Cable, internal SCSI disk
drive
7012/320/32H 31G9675 Cable, internal SCSI disk
drive
7012 models above 43G0779 Cable, internal SCSI disk
32H and below 380 drive
7012/380/390/39H/397 52G4850 Cable, internal SCSI disk
drive
7012/G30/G40 11H3928 Cable, internal SCSI 4-drop
11H3929 Cable, internal SCSI 6-drop
190 00G0976 Cable, internal SCSI disk
7013 Below 570 drive
(cont.) except 55L
7013/55L 65G7539 Cable, internal SCSI disk
drive
7013/570 65G7537 Cable, internal SCSI disk
drive
7013 above 570 65G7538 Cable, internal SCSI disk
drive
7013 All models 00G0977 Cable, 2nd internal SCSI,
except 55L (feature) 4-drop (8-bit)
7013 All models 52G7451 Cable, 2nd internal SCSI,
except 55L (feature) 6-drop (8-bit)
7013 All models 52G4430 Cable, 2nd internal SCSI,
except 55L (feature) 6-drop (16-bit)
7013 55L (feature) 52G7450 Cable 2nd internal SCSI,
4-drop (8-bit)
7013/595 65G7538 Cable, Internal SCSI
39H9274 Cable, Integrated SCSI-2
52G7451 (base)
52G4430 Cable, 6-drop, 8-bit SCSI
Cable, 6-drop, 16-bit SCSI
7013/J30/J40/J50 19H0398 Cable, internal SCSI
190 7015/930/950 00G0978 Cable, CPU drawer, SCSI
device
(cont.) 7015/970/980 10G8718 Cable, SCSI, CPU Enclosure
(outside of carrier-lower
docking connector)
7015/970/980 10G8720 Cable, SCSI, CPU Enclosure
(outside of carrier-upper
docking connector)
7015/97B/98B/990 52G5771 Cable, SCSI, CPU Media
Enclosure
7015/R10/R20/R21 88G3325 Cable, SCSI, CPU Drawer
7015/R24 88G4693 Cable, SCSI, CPU Drawer,
Disk Drive Carrier
7015/R24 88G4694 Cable, SCSI, CPU Drawer,
(to adapter)
7015/R30/R40 11H2681 Cable, SCSI, Media Module,
40H0482 Cable, SCSI (to SCSI
adapter)
7015/R50 93H5067 Cable, SCSI (DASD to Media
93H5066 board)
Cable, SCSI (to SCSI
adapter)
7016 00G0979 Cable, internal SCSI disk
drive
7018 00G0978 Cable, internal SCSI disk
drive
7030 52G4850 Cable, internal SCSI disk
drive
192 7203 00G2960 Power supply, portable disk
drive
195 7015 71F1072 Cable, SCSI device drawer
external signal
197 7015 00G0978 Cable, SCSI device drawer
internal signal
199 SCSI backplane (generic)
201 Unidentified SCSI device
drawer cable
203 7204 00G2960 Power supply
87G1642
7207/001/011 00G2960
7207/012 46G3934
7208/001 00G2960
7208/011 46G3934
7209 46G3934
7210/001 00G2960
7210/005 65G7585 Power supply/enclosure
205 46F2440 Cable, optical 6 m
46F2441 Cable, optical 10 m
46F2442 Cable, optical 20 m
46F2443 Cable, optical 60 m
46F2444 Cable, optical 100 m
208 7015 53F3524 Power distribution board
209 7015 70F9715 IPO switch assembly
210 Fixed-point processor
problem
7006/41T/41W 12H1281 System board, ID 42
7006/42T/42W 39H8152 System board, ID 91
7008 43G2429 System board, ID 43
7009/C10 40H5691 CPU card, ID 48
7009/C20 40H5693 CPU card, ID 90
7011/220 65G7374 System board, ID 41 or 45
7011/230 8184088 System board, ID 47
7011/250 51G8101 System board, ID 46 (66MHz)
8184306 System board, ID 49 (80MHz)
7012/320 91F1009 CPU card, ID 31
7012/32H 81F8232 CPU card, ID 35
210 Fixed Point Processor
Problem
(cont.) 7012/340 52G4190 CPU card, ID 37
7012/350 52G4007 CPU card, ID 38
7012/34H/355 51G9433 CPU card, ID 77
7012/360/36T/365 51G9437 CPU card, ID 76
7012/370/37T/375 51G9441 CPU card, ID 75
7012/380 11H3465 CPU card, ID 58
7012/390 88G4006 CPU card, ID 57
7012/39H 88G3536 CPU card, ID 59
210 Fixed Point Processor
Problem
(cont.) 7012/397 93H5557 System board, ID 94
7012/G30 35H8711 CPU Card, ID A6
7012/G40 35H8736 E4D CPU Card, ID A7
35H8737 E4M CPU Card (604-one way),
09J4713 ID
07L9397 CPU Card (604-two way)
CPU Card (604E-two way)
7013/520 71F1378 CPU planar, ID 30
7013/52H 00G3528 CPU planar, ID 34
7013/530 81F7888 CPU planar, ID 10
7013/53H 31F4350 CPU planar, ID 18
7013/540 53F3349 CPU planar, ID 14
7013/550 52G0020 CPU planar, ID 1C
7013/55L 51G9433 CPU card, ID 77
7013/560 51G9947 CPU planar, ID 5C
210 Fixed Point Processor
Problem
(cont.) 7013/570 65G7623 CPU planar, ID 67
7013/580 8184913 CPU planar, ID 66
7013/590 11H5127 CPU planar, ID 70
7013/591 39H9200 CPU planar, ID 79
7013/595 39H9164 CPU planar, ID 89
7013/58H 11H2375 CPU planar, ID 71
7013/59H 8184612 CPU planar, ID 72
7013/J30 35H8748 CPU Card (C1D), ID A0
7013/J40 09J4712 CPU Card (C4D), ID A1
7013/J50 07L9397 CPU Card (X4D), ID
7015/930 53F3350 CPU planar, ID 02 or 20
7015/950 52G5762 CPU planar, ID 2E
210 Fixed Point Processor
Problem
(cont.) 7015/970/97B 65G3448 CPU planar, ID 63
7015/980/98B 65G6896 CPU planar, ID 64
7015/990 88G0262 CPU planar, ID 80
7015/R10 65G7623 CPU planar, ID 67
7015/R20 8184612 CPU planar, ID 72
7015/R21 39H9200 CPU planar, ID 79
7015/R24 88G0007 CPU planar, ID 82
7015/R30 35H8748 CPU Card, ID A3
7015/R40 09J4712 CPU planar, ID A4
7015/R50 07L9397 CPU planar, ID
7016/730 81F7888 CPU planar, ID 10
7018/740/741 71F1378 CPU planar, ID 30
7018/770/771 65G7623 CPU planar, ID 30
210 Fixed Point Processor
Problem
(cont.) 7030/3AT 11H3465 CPU planar, ID 67
7030/3BT 11H3462 CPU card, ID 58
7030/3BT 11H3462 CPU card, ID 57
7030/3CT 88G3536 CPU card, ID 59
SPCL/POK System board, ID 81
9076/2008
Note: When working on a
9076, refer to the
following publications:
Scalable POWERparallel
Systems POWERparallel
Maintenance Information
Volume 2, and Maintenance
Analysis Procedures and
Parts Catalog.
212 Cache Problem
Note: For type/model and
FRU information, refer to
FFC 210.
214 Memory Control Unit Problem
7012/G30 35H8832 System board
7012/G40 09J4774 Note: For type/model and
7013/J30 19H0242 FRU information, other than
7013/J40 35H8778 the machine type or models
7013/J50 09J4816 listed refer to FFC 210.
7015/R30 19H0242
7015/R40 35H8778
7015/J50 09J4816
215 Optic Channel Support
Problem
7013/520 71F1378 CPU planar, ID 30
7013/52H 00G3528 CPU planar, ID 34
7013/530 81F7888 CPU planar, ID 10
7013/53H 31F4350 CPU planar, ID 18
7013/540 53F3349 CPU planar, ID 14
7013/550 52G0020 CPU planar, ID 1C
7013/560 51G9947 CPU planar, ID 5C
7013/570 65G7623 CPU planar, ID 67
7013/580 52G7363 CPU planar, ID 66
7015/930 53F3350 CPU planar, ID 02
7015/950 52G5762 CPU planar, ID 2E
7015/970/97B 65G3448 CPU planar, ID 63
7015/980/98B 65G6896 CPU planar, ID 64
215 Optic Channel Support
Problem
(cont). 7016/730 81F7888 CPU planar, ID 10
7018/740/741 71F1378 CPU planar, ID 30
7018/770/771 65G7623 CPU planar, ID 66
216 OCS ROM Problem
Note: For type/model and
FRU information, refer to
FFC 210.
217 System ROS/FEPROM
System board
7012/G30 35H8832
7012/G40 09J4774
7013/J30 19H0242 System board
7013/J40 35H8778
7013/J50 09J4816
7015/R30/R40 35H8780 I/O card
7015/R50 09J4760
Note: For type/model and
FRU information, other than
the machine type or models
listed refer to FFC 210.
218 Processor IOCC problem
(IOCC located in the
Processor)
Note: For type/model and
FRU information, refer to
FFC 210.
219 Common memory logic problem
Refer to Appendix C for
memory card and memory
module FRU numbers.
220 58F2903 Cable, RGB 3-position video
221 System I/O Control Logic
Problem
7006/41T/41W 12H1281 System board
7006/42T/42W 39H8152 System board
7008 43G2429 System board
7009/C10/C20 65G7904 System board
7011/220 65G7374 System board
7011/230 8184088 System board
7011/250 51G8101 System board (66MHz)
7011/250 8184306 System board (80MHz)
7012/320/32H 43G0534 System board
7012/340/350 51G8812 System board
7012/355/365/375 51G9107 System board
7012/34H/360/36T/ 00G2793 System board
370/37T
7012/380/390/39H 52G4325 System board
7012/397 93H5557 System board
221 System I/O Control Logic
Problem
(cont.) 7012/G30 35H8832 System board
7012/G40 09J4774
7013/520/530/540/ 00G3165 I/O planar
550/560/52H/53H
7013/55L 00G2793 System board
7013/570/580/58H/ 43G2211 I/O planar
590/591/59H
7013/595 40H7517 I/O planar
7013/J30/J40 35H8780 I/O card
7013/J30/J40/J50 95H0010 Micro-channel adapter
planar
7013/J50 09J4760 I/O card
7015/930/950 00G3165 I/O planar, CPU drawer
7015/930/950 59F3785 I/O planar, async drawer
7015/970/97B 65G3400 Combination planar
7015/970/97B 31F4324 Second I/O planar
221 System I/O Control Logic
Problem
(cont.) 7015/980/98B 65G3400 Combination planar
7015/980/98B 31F4324 Second I/O planar
7015/990 52G6071 Combination planar
31F4324 Second I/O planar
7015/R10/R20/R21 65G3009 I/O planar
7015/R24 52G6071 I/O planar
31F4324 Second I/O planar
7015/R30/R40 35H8780 IOD Card
7015/R30/R40/R50 35H8834 Micro-channel I/O planar
(PME)
7015/R50 09J4760 I/O Card
7016 00G3165 I/O planar
7018/740/741 00G3165 I/O planar
7018/770/771 52G1504 I/O planar
7030/3AT/3BT/3CT 52G4325 System Planar
SPCL/POK System board, ID 81
9076/2008
Note: When working on a
9076, refer to the
following publications:
Scalable POWERparallel
Systems POWERparallel
Maintenance Information
Volume 2, and Maintenance
Analysis Procedures and
Parts Catalog.
223 OCS Problem
7006 See Notes:
note 1 1. For type/model and FRU
7008 See note information, refer to
1 FFC 221.
7009 See note 2. For type/model and FRU
2 information refer to
7011 See note FFC 210.
1
7012/320/32H See note
1
7012 All others See note
2
7012/G30/G40 See note
1
7013 Below 570 except See note
55L 1
7013/55L See note
2
7013/J30/J40/J50 See note
1
7013 All others See note
2
223 OCS Problem
(cont.) 7015/930/950 See Notes:
note 1 1. For type/model and FRU
7015/R30/R40/R50 See note information, refer to
1 FFC 221.
7015 All others See note 2. For type/model and FRU
2 information refer to
7016 See note FFC 210.
1
7018/740/741 See note
1
7018/770/771 See note
2
7030 See note
2
226 System Status Logic Problem
Note: For type/model and
FRU information, refer to
FFC 221.
227 Micro Channel Logic Problem
Note: For type/model and
FRU information, refer to
FFC 221.
229 7204 42F7300 Fan
232 00G0972 Terminator, SCSI card edge
233 15F6743 Terminator, SCSI controller
external
234 Terminator, external SCSI
device. Refer to the
Cabling SCSI Devices
section in Adapters,
Devices, and Cable
Information manual.
239 7018/740 31F4221 Cable, SCSI controller,
7018/741 31F4223 except High-Availability
240 Token-ring network problem
241 Ethernet network problem
242 3270 network problem
244 X.25 network problem
245 Async Network Problem
251 8529214 Cable, parallel printer
252 7006 31F4590 Serial Dual Port cable
7009
7012/320/32H 00G0943 Standard I/O 10-pin to
25-pin converter cable, 12
in. (0.3 m)
7012/G30/G40 6450242 Cable, 9-pin to 25-pin
converter (3m)
7013 Below 570 except 00G0943 Standard I/O 10-pin to
55L 25-pin converter cable, 12
in. (0.3 m)
7015 Below 970 81F8977 CPU drawer standard I/O
10-pin to 25-pin converter
cable, 10 ft. (3 m)
7015/R30/R40/R50 6450242 Cable, 9-pin to 25-pin
converter (3m)
7016 00G0943 Standard I/O 10-pin to
25-pin converter cable, 12
in. (0.3 m)
253 Cable, multiprotocol,
EIA-422A, customer-provided
254 71F0165 Cable, 4-port multiprotocol
EIA-232, V.24
255 6247480 Cable, GIO adapter,
power/signal, Dials/ LPFK
256 6339098 Cable, token-ring, 10 ft.
(3.04 m)
53F3930 Cable, token-ring, 20 ft.
(6.08 m)
257 71F0162 Cable, 4-port
multiprotocol, V.35
258 40F9897 4-Port multiprotocol cable
259 6323741 Cable, async EIA-232D, V.24
260 71F0164 Cable, 4-port
multiprotocol, X.21
261 58F2861 Printer/terminal
interposer, EIA-232
262 00F5524 Multiport interface cable
263 30F8966 Terminal cable, EIA-422A
264 81F8234 Operator panel, async
expansion drawer
265 00G1109 64-Port controller cable
266 59F3432 RJ-45 to DB-25 converter
cable (4 cables)
267 7015 81F8570 Cable assembly, 4-port
multiprotocol jumper
268 7015 71F1379 Cable, async expansion
drawer signal
269 7015 53F3048 Cable assembly, 8/16-port
extension
270 39F8228 Cable, signal, serial port,
Dials/LPFK
271 53F3926 Cable, X.25 attachment
cable, X.21
272 53F3927 Cable, X.25 attachment
cable, V.24
273 53F3928 Cable, X.25 attachment
cable, V.35
274 6247480 Cable, graphics input
device dials
6247480 Cable, graphics input
device LPFK
275 0123786 Fuse, graphics input device
adapter
276 31F4221 Cable, SCSI controller
cable
277 Cable, Internal SCSI
Problem
Note: For type/model and
FRU information, refer to
FFC 190.
278 7018/740 31F4222 Cable, SCSI
device-to-device
7018/741 31F4224 Cable, SCSI
device-to-device
279 40F9736 Fuse, SCSI plug-in style
adapter
1383417 Fuse, integrated SCSI
adapter
Note: If the system unit
uses PTC resistors, refer
to Chapter 6. "MAP 0050:
SCSI Problems Isolation
Procedure".
280 Check power from display
and serial attachment power
and signal cables.
281 58F2903 Cable, 3-position video
283 7210 81F8216 Cable, Internal SCSI
284 93H8878 Speaker Cable
288 7015 59F3785 I/O planar, async expansion
drawer
290 43G0462 16-Port interface cable,
EIA-422A
291 43G0463 16-Port interface cable,
EIA-232
297 93H6057 DIMM Memory Module for the
GXT800M Graphics Adapter
650 Unknown IBM disk drive.
Note: This FFC indicates
the disk drive could not
properly configure. Refer
to the disk drive FRU part
number.
668 41H8917 25MB ATM MCA Adapter
678 59H2839 12GB 4mm SCSI Tape Drive
679 83H7105 4.5GB SCSD SE Disk Drive
680 93H9297 POWER GXT800M 3D Graphics
Adapter
681 59H6926 9.1GB Ultra-SCSI 16-bit
Disk drive
682 93H8055 20x (MAX) SCSI-2 CD ROM
Drive
684 93H6563 Enhanced Remote Async Node,
16-port RS-422
689 76H2697 4.5GB Ultra SCSI SE Disk
Drive
690 76H2698 9.1GB Ultra SCSI SE Disk
Drive
692 59H3121 7205-311 30GB DLT Tape
Bridge Box
694 93H5497 Eicon ISDN DIVA MCA Adapter
for PowerPC Sys.
700 74G6995 1.1GB 8-bit single-ended
disk drive assembly
74G6998 Electronics card assembly
7013/J30/J40/J50/J01 10H0265 Carrier with DC3 card for
the above drive.
701 74G7006 1.1GB 16-bit single-ended
disk drive assembly
74G7014 Electronics card assembly
7013/J30/J40/J50/J01 19H0207 1.1GB 16-bit single-ended
disk drive with carrier
19H0209 Carrier with DC6 card for
the above drive.
702 74G7009 1.1GB 16-bit differential
disk drive assembly
74G7015 Electronics card assembly
703 74G6996 2.2GB 8-bit single-ended
disk drive
74G6998 Electronics card asm. for
74G6996
7013/J30/J40/J50/J01 10H0265 Carrier with DC-3 Card
704 74G8824 2.2GB 16-bit SE disk drive
7006, 7009, 7012 74G8824 2.2GB 8-bit SE disk drive
7013, 7015 (8 bit)
Note: Add a jumper on pins
23 to 24 to operate in 8
bit mode.
Used with 16 to 8 bit
converter cable and
connector
93H6991 Cable: 68 pin
87G4587 Connector: 68 to 50 pin
7013/J30/J40/J50/J01 19H0203 2.2GB Disk Drive with
carrier
705 74G7010 2.2GB 16-bit differential
disk drive assembly
74G7015 Electronics card assembly
706 74G7008 4.5GB, 16 bit, SE SCSI Disk
Drive
74G7014 Electronics card assembly
use
with Part # 74G7008
7013/J30/J40/J50/J01 19H0208 4.5GB Drive with carrier
707 74G7011 4.5GB 16-bit differential
disk drive assembly
74G7015 Electronics card assembly
710 93H1527 POWER GXT150M Graphics
Subsystem
711 Unknown adapter
713 61G2916 ARTIC960 co-processor
platform
714 88G3711 Ultimedia Video I/O Adapter
715 88G2774 Ultimedia Audio Adapter
717 39H8817 TP Ethernet Adapter
718 7006 11H8879 GXT500 Graphics Adapter
721 Unknown SCSI device
722 Unknown disk drive
723 Unknown CD-ROM drive
724 Unknown tape drive
725 7008 43G0059 Display unit, Northern
Hemisphere
43G0069 Display unit, Southern
Hemisphere
other Unknown display adapter
type
726 Unknown input device
727 Unknown async device
728 Unknown parallel device
730 Unknown diskette drive
733 140GB 8mm Tape Drive
734 88G4921 Quad Speed SCSI-2 600MB
CD-ROM Drive
736 Quiet Touch Keyboard and
Speaker Cable
Note: The part number is
printed on the underside of
the keyboard.
741 84G9475 1080MB SCSI Disk Drive
745 7332/005 16GB 4mm Tape Autoloader
48GB 4mm Tape Autoloader
7332/110
Note: Service documentation
for this device will supply
FRU part numbers.
748 Keyboard/Mouse Adapter
Refer to FFC 821 for FRU
part number
749 7331 Model 205 8mm Tape
Library
Note: Service documentation
for this device will supply
FRU part numbers.
757 87G4858 SCSI 13GB 1/4 Inch Tape
Drive
772 93G2970 4.5GB SCSI F/W Disk Drive
74G7014 Electronics card asm.
7013/J30/J40/J50/J01 19H0209 Carrier with DC6 card for
the above drive
773 93G2972 9.1GB SCSI F/W Disk Drive
74G7014 Electronics card asm.
7013/J30/J40/J50/J01 19H0209 Carrier with DC6 card for
the above drive
774 7204 27H1677 9.1GB External SCSI
Differential Disk Drive
Model 339
77c 45G9467 1GB 16-bit Single-Ended
SCSI-2 Disk Drive
7013/J30/J40/J50/J01 19H0202 1GB 16-bit Single-Ended
SCSI-2 Disk Drive with
carrier
19H0209 Carrier with DC6 card for
the above drive
783 06H7541 24/48GB 4mm DDS-2 Tape
Autoloader (vertical
orientation)
42H2362 24/48GB 4mm DDS-2 Tape
Autoloader (horizontal
orientation)
41H8714 Tape Magazine
784 93H7151 2.1GB 8-bit SCSI-2 Disk
Drive
93H7152 2.1GB 16-bit SCSI-2 Disk
Drive
789 50G0212 7209 Model 003 External
2.6GB Rewritable Optical
Disk Drive
791 74G8824 2.2GB 16-bit single-ended
disk drive assembly
792 93G2970 4.5GB 16-bit single-ended
disk drive assembly
793 93G2972 9.1GB 16-bit single-ended
disk drive assembly
794 93H7888 10/100MB MCA Ethernet
Adapter
797 55H9378 TURBOWAYS 155 ATM UTP/STP
Adapter
798 73H1685 Video Streaming Adapter
800 72H3043 TURBOWAYS 155 ATM MMF
Adapter
804 73H2601 8x Speed SCSI-2 CD-ROM
Drive
807 SCSI Device Enclosure being
configured
80c 4-port SSA Adapter problem.
Refer to SSA Adapters:
User's Guide and
Maintenance Information.
811 System direct-attach bus
812 Common Standard Adapter
Logic
7006/41T/41W 12H1281 System board
7006/42T/42W 39H8152 System board
7008 43G2429 System board
7009 65G7904 I/O planar
7011 All models 31F4289 Serial/parallel riser card
7011/220 65G7374 System board
7011/230 8184088 System board
7011/250 51G8101 System board (66MHz)
7011/250 8184306 System board (80MHz)
7012/320/32H 43G0534 System board
7012/340/350 51G8812 System board
32G0176 Serial Flex Cable
812 Common Standard Adapter
Logic
(cont.) 7012/355/365/375 51G9107 System board
Serial Flex Cable
32G0176
7012/34H/360/36T/ 00G2793 System board
370/37T 32G0176 Serial Flex Cable
7012/380/390/39H 52G4325 System board
88G3623 Serial Hard Card
7012/397 93H5557 System board
7012/G30 35H8832 ELM System board
7012/G40 09J4774
7013/520 thru 560 53F3345 Standard I/O planar
7013/55L 00G2793 Standard I/O planar
94F3617 Serial Flex Cable
7013/570/580/590/ 43G2211 I/O planar
591/58H/59H 52G7347 Standard I/O flex circuit
812 Common Standard Adapter
Logic
(cont.) 7013/591 43G2211 I/O planar
7013/595 40H7517 I/O planar
7013/J30 35H8780 I/O card
35H8668 System Interface Board
7013/J40 35H8780 I/O card
35H8779 System Interface Board
7013/J50 09J4760 I/O card
35H8779 System Interface Board
7015/930/950 53F3345 Standard I/O planar, CPU
drawer
7015/970/97B/980/ 98B 65G3400 Combination planar
812 Common Standard Adapter
Logic
(cont.) 7015/990 52G6071 Combination planar
7015/R10 65G3009 I/O planar
7015/R20 65G3009 I/O planar
7015/R21 65G3009 I/O planar
7015/R24 52G6071 I/O planar
7015/R30 35H8780 I/O card
40H0421 System Interface Board
7015/R40 35H8780 I/O card
40H0421 System Interface Board
7015/R50 09J4760 I/O card
7016 53F3345 Standard I/O planar
7018/740/741 72X8488 Fuse, standard I/O planar
7018/770/771 52G1504 Flex circuit and I/O planar
7030/3AT/3BT/3CT 52G4325 System board
88G3623 Serial Hard Card
SPCL/POK System board, ID 81
9076/2008
Note: When working on a
9076, refer to the
following publications:
Scalable POWERparallel
Systems POWERparallel
Maintenance Information
Volume 2, and
813 Time of Day Battery
Note: Refer to FFC 151.
814 NVRAM Problem
For 7009 refer to
Notes:
note 1.
1. For type/model and FRU
For other mach. information, refer to
FFC 210.
types except
G, J, and R 2. For type/mocel and FRU
information, refer to
series refer FFC 221.
to note 2.
7012/G30 35H8832 System board
7012/G40 09J4774
7013/J30/J40 35H8780 IOD card
7013/J50 09J4760 I/O card
7015/R30/R40 35H8780 IOD card
7015/R50 09J4760 I/O card
815 Floating-Point Processor
Problem refer to FFC C68
Note: Refer to FFC 210.
816 Operator Panel Logic
Problem
7006/41T/41W 12H1281 System board
7006/42T/42W 39H8152 System board
7008 43G2429 System board
7009/C10 40H5691 CPU card
7009/C20 40H5693 CPU card
7011/220 65G7374 System board
7011/230 8184088 System board
7011/250 51G8101 System board (66MHz)
7011/250 8184306 System board (80MHz)
7012/320/32H 43G0534 System board
7012/340/350 51G8812 System board
7012/355/365/375 51G9107 System board
816 Operator Panel Logic
Problem
(cont.) 7012/34H/360/36T 00G2793 System board
7012/370/37T 00G2793 System board
7012/380/390/39H 52G4325 System board
7012/397 93H5557 System board
7012/G30 35H8832 System board
7012/G40 09J4774
7013 Below 570 except 00G3165 Standard I/O planar
55L
7013/55L 00G2793 I/O planar
7013/55L 94F3617 Operator panel assembly,
flex
7013/55L 65G7525 Operator panel riser card
7013/570/580/590 /58H 43G2211 I/O planar
816 Operator Panel Logic
Problem
(cont.) 7013/570/580/590 94F3592 Operator panel assembly,
/58H/59H flex
7013/591/59H 43G2211 I/O planar
7013/595 40H7517 I/O planar
7013/J30/J40 35H8780 I/O card
7013/J50 09J4760 I/O card
7015/930/950 53F3345 Standard I/O planar, CPU
drawer
7015/970/97B/980/ 98B 65G3400 Combination planar
7015/990 52G6071 Combination planar
7015/R10/R20/R21 65G3009 I/O planar
7015/R24 52G6071 I/O planar
7015/R30/R40 35H8780 I/O card
7015/R50 09J4760 I/O card
816 Operator Panel Logic
Problem
(cont.) 7016 00G3165 I/O planar
7018/740/741 00G3165 I/O planar
7018/770 52G1504 I/O planar
7018/770 52G1446 Operator panel assembly
7018/771 52G1504 I/O planar
7018/771 52G1485 Operator panel assembly
7030 52G4325 System board
Notes:
be done by you or the
customer:
1. Time and date must be
set.
2. Network IP addresses
should be set (for
machines that IPL from
a network).
3. The bootlist should be
set to reflect the
customers preference
for the IPL devices
(when set different
than the default
values).
817 Time-of-day Logic Problem
For 7009 refer
Notes:
to note 1.
1. For type/model and FRU
For other mach. information, refer to
FFC 210.
types except G,
2. For type/model and FRU
J, and R/30/R40/R50 information, refer to
FFC 221
refer to note 2.
7012/G30 35H8832 System board
7012/G40 09J4774
7013/J30/J40 35H8780 I/O card
7013/J50 09J4760 I/O card
7015/R30/R40 35H8780 I/O card
7015/R50 09J4760 I/O card
819 22F9758 Graphics input device
adapter
Note: Check the fuse before
exchanging the adapter.
821 All models except Built-in Keyboard Adapter
Problem
those listed
Note: For type/model and
FRU information, refer to
FFC 812.
7012/G30/G40 11H3890 Keyboard/Mouse Daughter
Card
7012/G30 35H8832 System board
7012/G40 09J4774 System board
7013/J30/J40/J50 40H7496 MCA Keyboard/Mouse Adapter
7015/R30/R40/R50 35H8780 I/O Planar
40H7012 System Interface Board
(SIB)
823 All models except Built-in Mouse Adapter
Problem
those listed
Note: For type/model and
FRU information, refer to
FFC 812.
7012/G30/G40 11H3890 Keyboard/Mouse Daughter
Card
7012/G30 35H8832 System board
7012/G40 09J4774 System board
7013/J30/J40/J50 40H7496 MCA Keyboard/Mouse Adapter
7015/R30/R40/R50 35H8780 I/O Planar
40H7012 System Interface Board
(SIB)
824 Not applicable Built-in Tablet Adapter
Problem
to G, J, and R
Note: For type/model and
series models FRU information, refer to
FFC 812.
825 Not applicable Built-in Speaker Adapter
Problem
to G, J, and R
Note: For type/model and
series models FRU information, refer to
FFC 812.
826 All (except those Built-in Serial Port S1
Problem
listed below)
Note: For type/model and
FRU information, refer to
FFC 812.
For 7013/J30 and 7015/R30,
refer also to FFC C88.
7015/970/97B/980/ 02G7307 Serial/Parallel ports data
98B/990/R24/ signal cable
827 All (except those Built-in Parallel Adapter
Problem
listed below)
Note: For type/model and
FRU information, refer to
FFC 812.
For 7013/J30 and 7015/R30,
refer also to FFC C88.
7015/970/97B/980/ 02G7307 Serial/Parallel ports data
98B/990/R24/ signal cable
828 Built-in Diskette Adapter
Problem
Note: For type/model and
FRU information, refer to
FFC 812.
For 7013/J30 and 7015/R30,
refer also to FFC 165
831 All (except those Built-in Serial Port S2
Adapter Problem
listed below)
Note: For type/model and
FRU information, refer to
FFC 812.
For 7013/J30/J40/J50 and
7015/R30/R40/R50, refer
also to FFC C88.
7015/970/97B/980/ 02G7307 Serial/Parallel ports data
98B/990/R24/ signal cable
834 32G1412 64-port async controller
835 43G0893 16-port async concentrator
836 52G4894 128-port async controller
837 51G8139 Remote Async Node, 16-port
EIA-232
93H6549 Enhanced Remote Async Node,
16-port EIA-232
Rack Mount Remote Async
Node, 16-port EIA-232
40H2589
838 51G8538 Network Terminal
Accelerator Adapter, 256
51G8539 Network Terminal
Accelerator Adapter, 2048
839 Network Terminal
Accelerator connection
station
841 32G1257 8-port async adapter,
EIA-232
842 52G4757 8-port async adapter,
EIA-422A
843 00G2436 8-port async adapter,
MIL-STD 188
844 7135 RAIDiant Array SCSI
subsystem controller
Note: Refer to 7135
documentation.
845 7135 RAIDiant Array SCSI 2.0GB
disk drive
Note: Refer to 7135
documentation.
846 7135 RAIDiant Array SCSI 1.3GB
disk drive
Note: Refer to 7135
documentation.
847 11H5762 16-port async adapter,
EIA-232
848 52G4739 16-port async adapter,
EIA-422A
849 51G9060 X.25 Interface
co-processor/2 (for
Multiport/2 adapter refer
to FFCs B60 through B66)
850 00G2652 Token-Ring network adapter
65G7568 Auto Token-Ring LANstreamer
MC 32 Adapter
851 51G9083 T1/J1 Portmaster Adapter/A
(U.S. and Japan)
852 00G3368 Ethernet LAN adapter
854 22F9743 3270 connection
855 52G4322 4-Port Multiprotocol
Communications Controller
(for Portmaster Adapter/A
refer to FFCs B69 through
B74)
8184299 Interface card
858 09G3667 5080 attachment adapter
859 81F9003 Fiber Distributed Data
Interface (FDDI)
Single-Ring Adapter (2-6)
65G1879 FDDI-Fiber Single-Ring
Adapter (2-R)
81F9014 FDDI Dual Ring Upgrade Kit
Adapter (2-7)
43G0856 FDDI Dual Ring Upgrade Kit
Adapter (2-S)
65G1878 FDDI-STP Single Ring
Adapter (2-T)
43G0876 FDDI-STP Dual Ring Upgrade
Kit Adapter (2-U)
85c 60G1593 Auto Token-Ring LANstreamer
MC32 adapter
861 59F2969 Serial optical channel
converter
862 02G7425 Block Multiplexer Channel
Adapter
865 56G0294 ESCON channel adapter or
emulator processor card
866 11H4779 SCSI-2 SE I/O controller
Note: Check the SCSI
controller fuse or PTC
resistor before exchanging
the planar. Refer to
"SCSI-1 Adapter Fuse
Blowing".
867 53F3621 Async expansion adapter
868 Integrated SCSI I/O
Controller Problem
7006/41T/41W 12H1281 System board (integrated
SCSI adapter) uses PTC
7006/42T/42W 39H8152 System board
7008 43G2429 System board (integrated
SCSI adapter)
7009 65G7904 I/O planar (integrated SCSI
adapter) uses PTC
7011/220 65G7374 System board (integrated
SCSI adapter)
7011/230 8184088 System board (integrated
SCSI adapter) uses PTC
7011/250 51G8101 Sys planar (integrated SCSI
adptr) uses PTC (66MHz)
7011/250 8184306 Sys planar (integrated SCSI
adptr) uses PTC (80MHz)
7012/340/350 51G8812 System board (integrated
SCSI adapter)
7012/34H/360/36T/ 00G2793 System board (integrated
370/37T SCSI adapter)
7012/355/365/375 51G9107 System board (integrated
SCSI adapter)
7012/380/390/39H 52G4325 System board
7012/397 93H5557 System board
7013/55L 00G2793 System board (integrated
SCSI adapter)
868 Integrated SCSI I/O
Controller Problem
(cont.) 7013/570/580/58H/ 43G2211 I/O planar (integrated SCSI
590/59H adapter)
7013/591 43G2211 I/O planar (integrated SCSI
adapter)
7013/595 40H7517 I/O planar (integrated
SCSI-2)
7015/970/97B/980/ 98B 65G3400 Combination planar
(integrated SCSI adapter)
7015/990 52G6071 I/O planar (integrated SCSI
adapter)
7015/R10/R20/R21 65G3009 I/O planar
7015/R24 52G6071 I/O planar
7018/770/771 52G1504 I/O planar (integrated SCSI
adapter)
7030/3AT/3BT/3CT 52G4325 System board
Note: Check the SCSI
controller fuse or PTC
resistor before exchanging
the planar. Refer to
"SCSI-1 Adapter Fuse
Blowing".
869 51G9425 SCSI I/O controller
40F9736 Fuse
Note: Check the fuse before
exchanging the planar.
Refer to "SCSI-1 Adapter
Fuse Blowing".
870 52G1071 High-performance disk drive
subsystem adapter
(40M-byte/sec, Type 4-3)
00G3357 High-performance disk drive
subsystem adapter
(80M-byte/sec, Type 4-5)
67G1862 High-performance disk drive
subsystem adapter
(40/80M-byte/sec, Type 4-8)
07G4859 cable, serial link, 3m (10
ft.)
07G4860 cable, serial link, 10m (33
ft.)
871 7016 53F6532 Graphics subsystem adapter
Note: If the problem still
exists after exchanging the
Graphics Subsystem Adapter,
exchange the following
cards, one at a time, in
the order listed.
34F3156 CVME interface card
74F3384 Graphics control processor
card
88G2965 Drawing processor card
74F3118 Shading processor card
53F6536 8-bit pixel memory card
53F6538 24-bit pixel memory card
871 7235 74F3158 Graphics subsystem adapter
(cont.) Note: If the problem still
exists after exchanging the
Graphics Subsystem Adapter,
exchange the following
cards, one at a time, in
the order listed. For
ordering purposes, refer to
the part number on the
card.
09G3515 CVME interface card
74F3384 Graphics control processor
card
88G2965 Drawing processor card
74F3118 Shading processor card
53F6536 8-bit pixel memory card
53F6538 24-bit pixel memory card
872 71F1224 Grayscale graphics adapter
874 71F1223 Color graphics adapter
876 71F1117 8-Bit color graphics card,
MDE1
877 00G1117 Base graphics card, POWER
Gt3
43G0681 POWER Gt3i
93H2945 POWER Gt4e 51G8022
878 51G9397 Graphics processor card,
POWER Gt4
Note: If the video is
malfunctioning, first check
that the setting of the
display frequency switch
(if present) agrees with
the card frequency. The
card default frequency is
60 Hz; 77 Hz can be set via
software. If the problem
still exists after
exchanging the processor
card, exchange the
following, one at a time,
in the order listed:
88G3988 Base graphics card, POWER
Gt4
51G9395 Field upgrade graphics
card, 8- to 24-bit, POWER
Gt4
70F9664 Performance option card,
POWER Gt4
51G9225 Cable, two-position.
Note: This FRU contains two
cables, one with black
connectors, 51G9224, and
one with brown connectors,
71F0253. If either of the
connectors on the cable
being replaced is brown,
the replacement cable with
the brown connectors must
be used; if neither of the
connectors on the cable
being replaced is brown,
the replacement cable with
the black connectors must
be used.
51G9227 Cable, three-position
Note: This FRU contains two
cables, one with black
connectors, 51G9226, and
one with brown connectors,
71F0254. If either of the
connectors on the cable
being replaced is brown,
the replacement cable with
the brown connectors must
be used; if neither of the
connectors on the cable
being replaced is brown,
the replacement cable with
the black connectors must
be used.
40H3441 POWER Gt4i processor card
40H3446 POWER Gt4xi processor card
11H4912 POWER Gt4xi 8-bit graphics
card
11H4913 POWER Gt4i 24-bit graphics
card
51G9225 Connector cable
(two-position)
879 71F1114 24-bit color graphics card,
MEV2
880 7008 43G2429 System board
7011/220/230 10G8659 Graphics adapter, POWER Gt1
887 Integrated Ethernet Problem
7006/41T/41W 12H1281 System board, integrated
Ethernet adapter
7006/42T/42W 39H8152 System board
7008 43G2429 System board
7011/220 65G7374 System board
7011/230 8184088 System board, integrated
Ethernet adapter (66MHz)
7011/250 51G8101 System board, integrated
Ethernet adapter (80MHz)
7011/250 8184306 System board, integrated
Ethernet adapter
7012/340/350 51G8812 System board, integrated
Ethernet adapter
7012/34H/360/36T/ 00G2793 System board, integrated
370/37T Ethernet adapter
7012/355/365/375 51G9107 System board, integrated
Ethernet adapter
7012/380/390/39H 52G4325 System board, integrated
Ethernet adapter
7012/397 93H5557 System board, integrated
Ethernet adapter
7013/55L 00G2793 System board, integrated
Ethernet adapter
7030 52G4325 System board, integrated
Ethernet adapter
889 11H2447 SCSI-2 differential high
performance external I/O
controller
Note: Check the SCSI
controller PTC resistor
before exchanging the
planar. Refer to "PTC
Tripping (SCSI-2 SE
Controller, Integrated SCSI
on 7012/340 thru 375,
7013/550L, 570 thru 59H,
7015/R10 thru R24".
890 65G7315 SCSI-2 Differential
Fast/Wide Adapter/A
98H8814 SCSI-2 Single-Ended
Fast/Wide Adapter/A
52G3380 Enhanced SCSI-2
Differential Fast/Wide
Adapter/A
7013/595 40H7517 I/O planar Integrated SCSI
Fast/Wide
891 Vendor SCSI adapter
892 Vendor display adapter
893 Vendor LAN adapter
894 Vendor async communications
adapter
897 65G1828 S/370 Channel Emulator/A
898 7011/220/230 51G7773 POWER Gt1x graphics adapter
89c 7006 88G4898 600MB Double Speed
7009 Tray-Loading CD ROM
7012/380/390/G30 /G40
7013/J30/J40/J50/J01 19H0206 600MB Double Speed
Tray-Loading CD ROM with
carrier.
19H0264 Carrier with DC5 card for
the above device.
7013 other models 88G4898 600MB Double Speed
7015 models after 950 Tray-Loading CD ROM
and all R series
7030
901 Vendor SCSI device
902 Vendor display
903 Vendor async device
904 Vendor parallel device
905 Other vendor device
908 7250 (All 40H3571 POWER GXT1000 Graphics
Attachment Adapter (SPAN)
models)
910 All 40H2648 1/4GB Fibre Channel/266
Standard Adapter
911 All 12H1292 Fibre Channel 1063 Short
Wave Adapter
912 86F0119 2.0GB SCSI-2 differential
disk drive
86F0125 Differential frame
electronics
Note: Check RETAIN for
frame electronics
availability. Exchange the
complete drive assembly
whenever possible. Exchange
the logic card only when
the data on the disk must
be saved.
913 6374682 1GB differential disk
drive, half-height
6374683 Differential frame
electronics
Note: Check RETAIN for
frame electronics
availability. Exchange the
complete drive assembly
whenever possible. Exchange
the logic card only when
the data on the disk must
be saved.
914 16G8492 5GB 8mm differential tape
drive
915 All except 21H5172 4GB 4mm tape drive
7013/J series
7013/J30/J40/J50 19H0213 4GB 4mm tape drive with
carrier
19H0264 Carrier with DC5 card for
the above device.
917 86F0767 2.OGB Differential
Fast/Wide Disk Drive
Note: If the disk drive is
in a 7134 drawer, replace
with FRU P/N 67G3022
918 86F0766 2.0GB 16-bit Single-Ended
Fast/Wide Disk Drive
19H0201 2.0GB 16-bit Single-Ended
Fast/Wide Disk Drive
carrier
19H0209 Carrier with DC6 card for
the above drive.
921 101 Key Keyboard
51G8572 Keyboard U.S. English
8184692 Keyboard, U.S. (Soft Touch)
English
1394609 Keyboard cable
922 1396079 Keyboard, Arabic
1394543 Keyboard,
Belgium-French/Dutch
88G3936 Keyboard, Brazilian
1394544 Keyboard, Danish
43G2778 Keyboard, Dutch/Netherlands
1394545 Keyboard, Finnish/Swedish
1394546 Keyboard, French
1394541 Keyboard, French-Canadian
1394542 Keyboard, German
1396078 Keyboard, Greek
1396080 Keyboard, Hebrew
922 1395968 Keyboard, Icelandic
1394547 Keyboard, Italian
(cont.)
1394548 Keyboard, Norwegian
1394549 Keyboard, Portuguese
1394550 Keyboard, Spanish
1394551 Keyboard,
Swiss-German/French
1396077 Keyboard, Turkish (ID 179)
43G2775 Keyboard, Turkish (ID 440)
1395985 Keyboard, U.K. English
1394609 Keyboard cable
923 106 keys International
Keyboard
30F9388 Keyboard, Japanese-Kanji
02G7352 Keyboard, Korean
02G7353 Keyboard, Taiwanese
924 61X8923 2-Button mouse
925 11H4878 3-Button mouse
926 6247450 Tablet, 5083 Model 21
74F3130 Tablet, 6093 Model 11
927 6247452 Tablet, 5083 Model 22
74F3140 Tablet, 6093 Model 12
93H7714 Tablet, 6093 Model 21
929 39F8227 Dials, 6094 Model 10
39F8302 Cable, serial attachment,
power
930 39F8226 Lighted Program Function
Keyboard (LPFK), 6094 Model
20
39F8302 Cable, serial attachment,
power
931 6487683 5085 Keyboard, U.S.
6487686 5085 Keyboard, France
59X1088 5085 Keyboard, Germany
6487687 5085 Keyboard, Italy
60X5726 5085 Keyboard, Japan
6487689 5085 Keyboard, Sweden
(obsoleted)
6487685 5085 Keyboard, U.K. English
6247440 5086 Keyboard, U.S.
6247442 5086 Keyboard, France
6247444 5086 Keyboard, Germany
6247443 5086 Keyboard, Italy
6247446 5086 Keyboard, Japan
6247445 5086 Keyboard, Sweden
6247441 5086 Keyboard, U.K. English
935 7006/41T/41W 52G3400 4M-byte (2.88 M-byte),
/42T/42W 3.5-inch diskette drive
7009
7011
7012 88G4768 2M-byte (1.44 M-byte),
7013 3.5-inch diskette drive
7015
7016 53F3423
7018
936 71F1042 5.25-inch diskette drive,
1.2M-byte, internal
937 51G9994 HIPPI Micro Channel Adapter
Card
942 7011/250 52G3206 GXT100 Graphics adapter
error
52G3207 GXT150 Graphics adapter
error
944 7009/C10 73G9821 100MB ATM adapter being
7013/59H configured
945 45G9467 1.0GB 16-bit SCSI
differential disk drive
946 Standard Serial Port 3
Problem
7012/G30 35H8832 System board
7012/G40 09J4774 System board
7013/J30/J40 35H8780 I/O card
7013/J50 09J4760 I/O card
7015/R30/R40 35H8780 I/O card
7015/R50 09J4760 I/O card
949 Unknown direct-attached
disk drive is failing
950 Unknown SCSI device is
missing.
951 53F3429 670M-byte SCSI disk drive
assembly
6373521 Logic card
Note: Exchange the complete
drive assembly whenever
possible. If extreme
data-saving measures are
necessary, exchange the
logic card.
952 53F3427 355M-byte SCSI disk drive
assembly
6373521 Logic Card
Note: Exchange the complete
drive assembly whenever
possible. If extreme
data-saving measures are
necessary, exchange the
logic card.
953 93X0961 320M-byte SCSI disk drive
assembly
93X0901 Logic card and frame
assembly
Note: Exchange the complete
drive assembly whenever
possible. Exchange the
logic card only when the
data on the disk must be
saved.
954 73F9001 400M-byte disk drive
assembly
73F8994 Logic card and frame
assembly
Note: Exchange the complete
drive assembly whenever
possible. Exchange the
logic card only when the
data on the disk must be
saved.
955 45G9495 857M-byte disk drive
assembly
95X2346 857M-byte logic card and
frame assembly
95X2432 857M-byte logic card and
frame assembly
91F0935 Isolator kit for 7016
Note: Check RETAIN for
frame electronics
availability. Exchange the
complete drive assembly
whenever possible. Exchange
the logic card only when
the data on the disk must
be saved. Refer to RETAIN
TDR -064942 for more
information. 95X2346 must
be used with the 95X2431
disk enclosure.
45G9904 857MB Mounting plate
956 6373521 355/670M-byte logic card.
957 7012/320 53F3425 120M-byte Direct Bus Attach
disk drive
81F8900 Riser card, disk drive
958 7012/320 00G2603 160M-byte Direct bus attach
disk drive
7012/32H 81F8900 Riser card, disk drive
959 7008/M2A/M20 1383417 Fuse, riser card
7011/220/230/250 31F4288 Riser card, disk drive
7012/340/34H/350/ 00G2603 160M-byte SCSI disk drive
355/360/36T/ 370/37T
960 52G0061 1.37GB SCSI disk drive
assembly
31G9756 Logic card
Note: Logic card stocking
will be limited, and
special ordering may be
required. Check RETAIN for
logic card availability.
Exchange the complete drive
assembly whenever possible.
Exchange the logic card
only when the data on the
disk must be saved.
962 3161 Use device documentation.
963 3163 Use device documentation.
964 59H3879 12GB External 4mm Tape
Drive
59H2839 20GB 8mm SCSI Tape Drive
(internal)
59H2835 20GB 8mm SCSI Tape Drive
(external)
59H2842 400GB 8mm SCSI Tape
Autoloader
968 55F9902 1GB single-ended disk drive
assembly, half-height
55F9909 Single-ended frame
electronics
19H0265 Carrier with DC3 card for
the above drive.
Note: Check RETAIN for
frame electronics
availability. Exchange the
complete drive assembly
whenever possible. Exchange
the logic card only when
the data on the disk must
be saved.
970 9348 1/2-Inch 9-Track Tape Drive
Use device documentation.
971 16G8423 150M-byte 1/4-Inch Tape
Drive
972 16G8421 2.3GB 8 mm Tape Drive
973 Other SCSI tape drive
974 88G3929 CD-ROM drive (Type A or
Type B bezel)
977 51G8018 M-Audio Capture and
Playback Adapter
980 4216 Use device documentation.
981 51G8237 540M-byte SCSI-2
single-ended disk drive
19H0265 Carrier with DC3 card for
the above drive.
982 3852 Use device documentation.
983 4201 Use device documentation.
984 45G9467 1GB 8-bit disk drive
(one-inch height)
7013/J30/J40/J50/J01 19H0202 1GB 8-bit disk drive
(one-inch height) with
carrier.
19H0265 Carrier with DC3 card for
the above drive.
985 M-Video Capture Adapter
(M-VCA)
32G0258 NTSC version (U.S.)
92F3713 NTSC cable set
32G0263 PAL version (non-U.S.)
92F3714 PAL cable set
986 36G0454 2.4GB SCSI disk drive
assembly
Note: For field repair
assembly, see Failing
Function Code C11.
987 7012/G30/G40 88G4898 600MB CD-ROM-2 drive (Type
7013/59H/J30/ B bezel, has white
J40/J50/J01 underside on unload button)
7013/J30/J40/ J50/J01 19H0206 600MB CD-ROM-2 drive with
carrier
19H0266 Carrier with DC5 card for
the above device.
All other models 65G7563 600MB CD-ROM-2 drive
989 43G1842 200M-byte SCSI disk drive
990 86F0118 2.0GB SCSI-2 single-ended
disk drive
86F0110 Single-ended frame
electronics
7013/J30/J40/ J50/J01 19H0201 2.0GB SCSI-2 single-ended
disk drive with carrier.
19H0265 Carrier with DC3 card for
the above drive.
Note: Check RETAIN for
frame electronics
availability. Exchange the
complete drive assembly
whenever possible. Exchange
the logic card only when
the data on the disk must
be saved.
991 7207 46G2700 525M-byte 1/4-inch SCSI
tape drive
992 5202 Use device documentation.
993 5204 Use device documentation.
994 All models 21H5151 5/10GB 8-mm internal tape
drive
7013/J30/J40/ J50/J01 19H0204 5/10GB 8-mm internal tape
drive with carrier
19H0266 Carrier with DC5 card for
the above device.
995 8191184 1.2GB 1/4-inch cartridge
tape drive
996 43G0656 Multi-Protocol Adapter
997 65G1878 FDDI-STP (shielded
twisted-pair) single-ring
adapter
998 55F9306 2.0GB 4mm-tape drive
* 61F5396 Voice Server Attachment
Adapter (VSCA) (61F5396
obsolete)
* No Failing Function Code
exists. For detailed
diagnostic information,
refer to the
DirectTalk/6000 Problem
Solving Guide, form number
SC-22-0105.
* 34F0873 Voice Server Attachment
Adapter cable
* No Failing Function Code
exists. For detailed
diagnostic information,
refer to the
DirectTalk/6000 Problem
Solving Guide, form number
SC22-0105.
* 43G3317 Voice Server Dual
Attachment Adapter (VSDA)
* No Failing Function Code
exists. For detailed
diagnostic information,
refer to the
DirectTalk/6000 Problem
Solving Guide, form number
SC-22-0105.
999 3514 Disk Array Subsystems Note:
Refer to the 3514 or 7137
7137 documentation.
B01 00G2916 Processor card, POWER Gt3
B04 92F6697 Cable, Block Multiplexer
Channel Adapter
B05 25F9401 Channel cable interface box
B06 43G0382 Ethernet thick and thin
7012/34H/355/360 riser card
/36T/365/370
/37T/375/380 Note: Check the Ethernet
/390/39H/397 fuse before replacing the
7013/550L planar.
7030
B07 00G1276 Ethernet twisted-pair riser
7012/34H/355/360 card
/36T/365/370
/37T/375/380 Note: Check the Ethernet
/390/39H/397 fuse before replacing the
7013/550L planar.
7030
B08 02G7431 Ethernet 10 Base
Twisted-pair transceiver
B09 02G7437 Ethernet/ISO 8802/3
(formerly IEEE 802.3)
transceiver
B10 81F8129 System board fuse or PTC
(thermal fuse)
Note: If a thermal fuse has
opened, it should reset
within ten minutes after
powering off the system. If
the thermal fuse does not
reset, a faulty device may
be drawing excessive power
through the fuse.
B11 00G1295 Fuse for thick/thin riser
7012/355/360/ card
36T/365/370/
37T/375
7012/380/390/39H/397 43G0382
7030
B14 All except 81F9014 Fiber Distributed Data
Interface (FDDI) dual ring
7011/220/230 upgrade adapter
43G0856 FDDI-Fiber dual ring
upgrade adapter
B15 All except 81F9012 Fiber Distributed Data
Interface (FDDI) crossover
7011/220/230 cable
93F1162 FDDI-Fiber crossover cable
B16 70F9664 Performance Option card,
POWER Gt4
B19 Socketed TCW Memory DIMM
Problem CPU Card
7012/320 91F1009
7012/32H 81F8232
7012/340 52G4190
7012/350 52G4007
7012/34H/355/360 90X8624 Translation Control Word
/36T/365/370 /37T/375 (TCW) memory module
7012/380 11H3465 CPU Card
7012/390/39H 88G4006
7012/397 93H5557 System board
7013/520 71F1378 CPU Planar
7013/52H 00G3528
7013/530 81F7888
7013/53H 31F4350
7013/540 53F3349
7013/550 52G0020
7013/560 51G9947
B19 Socketed TCW Memory DIMM
Problem
(cont.) 7013/55L/570/580 90X8624 Translation Control Word
/58H/590/591 (TCW) memory module
7013/59H 8184612 CPU Planar
7015/970/97B/980 90X8624 Translation Control Word
/98B/R10/R20 /R21 (TCW) memory module
7015/990/R24 52G6128 CPU Planar
7030/3AT 11H3465 CPU Card
7030/3BT 11H3462
7030/3CT 88G3536
B20 7012/350 52G4007 CPU card
B21 7012/340 52G4190 CPU card
B23 7015/970/97B 65G3448 CPU planar
B24 7011/220 65G7374 System board
B26 7012/340/350 51G8812 System board
B28 7012/397 93H5557 System board
7013/570/58H/590 /59H 43G2211 I/O planar
7013/591 43G2211
7013/595 40H7517
7015/970/97B/980 /98B 65G3400 Standard I/O planar
7015/990/R24 52G6071
7015/R10/R20/R21 65G3009 I/O planar
B29 7011/220 65G7374 System board
B31 Unknown keyboard type
B34 7008 43G2429 System board (video RAM)
7011/220 00G2393 POWER Gt1 video RAM
(1M-byte)
B35 7011/220/230 31F4292 POWER Gt1 riser card
B36 Unidentifiable Memory
module
19H0240 MR2 8MB Memory module
19H0271 MR4 32MB Memory module
35H8694 8MB memory JEDEC Memory
module
19H0288 16MB memory JEDEC Memory
module
19H0289 32MB memory JEDEC Memory
module
35H8751 64MB memory JEDEC Memory
module
B37 7006 8184416 2M-byte memory module
7009
7011/250
B38 7006 51G8553 4M-byte memory module
7009
7011/220/230/250
B39 7006 51G8554 8M-byte memory module
7009
7011/220/230/250
B40 7011/220/230 1383417 Planar ethernet fuse
Note: If a thermal fuse has
opened, it should reset
within ten minutes after
powering off the system. If
the thermal fuse does not
reset, a faulty device may
be drawing excessive power
through the fuse.
B41 7011 31F4288 I/O slot riser card
B42 7011/220/230 31F4292 Graphics adapter riser card
B45 43G0876 FDDI-STP dual ring upgrade
kit
B46 93F1162 FDDI-STP crossover cable
B47 56G0295 ESCON channel adapter or
emulator fiber optic
subassembly
B48 Unidentifiable Memory Card
35H8694 MRE memory card without
memory modules
19H0234 MRB2 memory card without
memory modules
19H0236 NFx memeory card without
memory modules
19H0284 MRB4 memory card without
memory modules
11H5059 RLx memory card without
memory modules
73H1567 SF5 memory card without
memory modules
B50 7235 09G3549 Drawing processor card
B51 7235 09G3521 Shading processor card
B52 7235 09G3533 8-bit pixel memory card
B53 7235 09G3534 24-bit pixel memory card
B54 43G0936 128-port async controller
cable, 0.2 m
(9 in.)
43G0937 128-port async controller
cable, 4.6 m
(15 ft.)
B56 32G1866 S3.3 memory base card
B57 7012 43G1796 16M-byte memory card module
7013
7015
B58 43G0681 POWER Gt3i graphics adapter
B59 51G8022 POWER Gt4e graphics adapter
B60 09F1888 Multiport/2 512K-byte base
card
B61 09F1962 Multiport/2 1M-byte base
card
B62 91F7976 4-port EIA-232-C
Multiport/2 Interface Card
B63 91F7974 8-port EIA-232-C
Multiport/2 Interface Card
B64 91F7966 4-port EIA-232-C/4-port
EIA-422-A Multiport/2
Interface Card
15F8858 8-port EIA-422-A
Multiport/2 Interface Card
B65 91F7963 6-port synchronous
EIA-232-C Multiport/2
Interface Card
B66 15F8858 8-port EIA-422-A
Multiport/2 Interface Card
B67 16F2267 Multiport/2 256K-byte
memory module package
B68 16F2265 Multiport/2 512K-byte
memory module package
B69 53F2603 Portmaster base card
B71 53F2612 8-port EIA-232-D Portmaster
Interface Card
B72 53F2615 8-port EIA-422-A Portmaster
Interface Card
B73 72F0164 6-port V.35 Portmaster
Interface Card
B74 04G5500 6-port X.21 Portmaster
Interface Card
B75 7008 43G2429 System board
B76 7008 43G0059 Display unit, Northern
Hemisphere
43G0069 Display unit, Southern
Hemisphere
B77 53F2662 Portmaster 1M-byte memory
module
B78 53F2666 Portmaster 2M-byte module
B79 00F5524 Multiport/2 interface cable
(non-synchronous)
Note: If cable has an 8
port or 6 port fanout box.
B80 15F8868 Multiport/2 synchronous
interface cable
B81 53F2621 8-port Portmaster interface
cable
B82 72F1966 6-port V.35 Portmaster
interface cable
B83 04G5501 6-port X.21 Portmaster
interface cable
B84 7015/980 65G6896 CPU planar
B85 7013/580 8184913 CPU planar
B86 43G2211 I/O planar
7013/570/580/590
/58H/59H/591
7013/595 40H7517
7015/R10/R20/R21 65G3009
B87 7012/34H/360/ 00G2793 System board
36T/370/37T
7012/355/365/375 51G9107
7013/55L 00G2793
B88 Generic SCSI I/O controller
Note: Refer to the FRU Name
Cross-Reference List in
this book for the FFCs of
the SCSI and SCSI-2
adapters that this generic
FFC represents. Choose the
FFC for the appropriate
SCSI I/O controller.
Check the SCSI controller
fuse or PTC resistor before
exchanging the planar.
Refer to "PTC Tripping
(SCSI-2 SE Controller,
Integrated SCSI on 7012/340
thru 375, 7013/550L, 570
thru 59H, 7015/R10 thru
R24".
Check that the SCSI disable
jumper is in the enabled
position.
Check the FRU number of the
installed external
terminator: Low density -
51G7736 High density -
51G7737
For 7012/G series, 7013/J
series, and 7015/R30 system
units refer also to FFC 221
and C90.
B89 7012/360/36T/365 51G9437 CPU card
7013/55L 51G9433
B90 7012/370/37T/375 51G9441 CPU card
B91 7012/34H/355 51G9433 CPU card
B92 7013/570 65G7623 CPU card
7015/R10
B93 7011/230 8184088 System board
B94 19H0283 MRB2 base memory card
(without memory modules)
B96 19H0240 8 MB MR2 Memory module
B97 19H0271 32 MB MR4 Memory module
B98 SMP Data Cross Bar
7012/G30 35H8832 System Planar
7012/G40 09J4774
7013/J30 19H0242
7013/J40 35H8778
7013/J50 09J4816
7015/R30 19H0242
7015/R40 35H8778
7015/R50 09J4816
C08 51G9996 HIPPI Transmit Card
C09 51G9995 HIPPI Receive Card
C10 51G9226 Top-card cables
C11 36G4280 2.4GB SCSI disk drive field
repair assembly
Note: The field repair
assembly includes one disk
drive, the electronics
planar, and the 5-1/4 inch
form factor "cage." The
remaining "good" drive is
removed from the failed
disk drive assembly and
installed in the field
repair assembly to create a
complete dual-disk drive
assembly. If saving data is
critical, as a last resort
try installing the "bad"
drive in place of one of
the two "good" drives in
the now-complete field
repair assembly. If the
"bad" drive operates
satisfactorily, the problem
was probably in the
electronics planar.
C12 7016 88G2965 Drawing processor
7235/001/7235/002
7235/01i/7235/02i 09G3549
C13 7016 74F3118 Shading processor
7235/002 74F3118
7235/02i 09G3521
C14 7016 53F6538 24-bit pixel memory card
7016 53F6536 8-bit pixel memory card
7235/001 53F6536 8-bit pixel memory card
7235/002 53F6538 24-bit pixel memory card
7235/01i 09G3533 8-bit pixel memory card
7235/02i 09G3534 24-bit pixel memory card
C16 Generic reference for the
Portmaster interface card.
The FRU for this FFC could
be associated with any of
the following: B69, B71,
B72, B73 or B74. Refer to
information for the
applicable FFC.
C17 Generic reference for the
Multiport/2 interface card.
The FRU for this FFC could
be associated with any of
the following: B62, B63,
B64, B65 or B66. Refer to
information for the
applicable FFC.
C18 51G9361 E1 Portmaster Adapter/A
(Europe)
C19 51G9431 T1/J1 Portmaster cable
(U.S. and Japan)
C20 51G9432 E1 Portmaster cable
(Europe)
C21 68F7209 S/370 Channel Emulator/A
Interface cable
C22 49G0935 RJ-45 to DB-25 converter
cable kit (four cables)
C23 7012/340 52G4190 CPU card
7012/350 52G4007
7012/34H/355 51G9433
7012/360/36T/365 51G9437
7012/370/37T/375 51G9441
7013/55L 51G9433
C24 Fiber optics cable
C25 7011/250 8184016 Riser card, graphics
adapter
C26 65G7315 SCSI-2 Differential
Fast/Wide Adapter/A
C27 7006/41T/41W 12H1281 System board
7006/42T/42W 39H8152
7009/C10/C20 65G7904
7011/250 51G8101 System board (66MHz)
7011/25F 8184306 System board (80MHz)
C28 7006/41T/41W 93H1527 GXT150 Graphics adapter
error
7011/250 52G3206 POWER GXT100 graphics
adapter
52G3207 POWER GXT150 graphics
adapter
C29 7006 51G8479 RJ-45 Ethernet converter
7011/250
C30 65G6452 32M-byte S4.5 memory module
C31 7006 8184379 16M-byte memory module
7009
7011/250
C32 7006 88G2807 32M-byte memory module
7009 73G3235
7011/250
C33 7250/001 with
S/Ns
7250-26-nnnnn 40H6494 GPSS board
7250-26-Annnn 11H8507
7250/002 with
S/Ns
7250-26-nnnnn 40H4123 GPSS board
7250-26-Annnn 11H8491 GPSS board
C34 7250/001 with
S/Ns
7250-26-nnnnn 11H8539 RSS board
7250-26-Annnn 11H8484
7250/002 with
S/Ns
7250-26-nnnnn 40H4063 RSS board
7250-26-Annnn 11H8490 RSS board (without memory
sockets)
C35 7250 (All 65G4887 VOO board
models)
C36 7250 (All 65G4892 Attachment adapter cable
models)
C37 7012/39H 88G3536 CPU Card (If slot callout
7030/3CT is slot location D.)
9076/SP2 65G1803 S4.5 base memory card (If
slot callout is any slot
except D.)
All other models refer
to table in Appendix C
C38 59F4581 1M-byte memory memory
C39 59F4582 2M-byte memory module
C40 70F9973 4M-byte memory module
C41 70F9976 8M-byte memory module
C42 43G1796 16M-byte memory module
C43 7013 65G6452 32M-byte memory module
7015
C44 7250 (All 65G4894 VOO/RSS Crossover cable
models)
C45 7250/002 65G4889 12M VRAM memory module
(Base and
AG Mem.)
C46 7250/002 65G4890 16M VRAM memory module
(Base and
AG Mem.)
C47 7250/002 65G4891 16M DRAM memory module
(TX Memory)
C48 7250 (All 65G4893 RSS/GPSS Crossover board
models)
C49 40H3441 POWER Gt4-i processor card
C50 40H3446 POWER Gt4-i processor card
C51 11H4912 POWER Gt4-i 8-bit graphics
card
C52 11H4913 POWER Gt4-i 24-bit graphics
card
C53 7015/990 88G0262 CPU planar ID 80
C54 7012/397 93H5557 System board ID 94
7013/590 8184825 CPU planar ID 70
7013/591 39H9200 CPU planar ID 79
7013/595 39H9164 CPU planar ID 89
C55 7012/380/390/39H 52G4325 Integrated SCSI-2 Fast/Wide
Adapter on the system
board. Replace the system
board.
7012/397 93H5557 System board
7030 52G4325 System board
C56 7013/58H 11H2375 CPU planar
C57 7013/58H 43G2211 I/O planar
C58 7015/990 52G6071 Combination planar
C59 7012/G30 35H8832 System board
7012/G40 09J4774 System board
7013/J30/J40 35H8780 I/O card
7013/J50 09J4760 I/O card
7015/R30/R40 35H8780 I/O card
7015/R50 09J4760 I/O card
C61 7012/G30 35H8832 System board
7012/G40 09J4774
7013/J30 19H0242
7013/J40 35H8778
7013/J50 09J4816
7015/R30 19H0242
7015/R40 35H8778
7015/R50 09J4816
C62 E1M Single CPU card
C63 35H8748 C1D Dual CPU card with 1MB
cache
C64 19H0284 MRB4 base memory card
C65 35H8750 E1D Dual CPU card with
512KB cache
C66 RLx memory card without
memory modules
C68 Unidentifiable CPU Card
7012/G30 35H8832 System board (ELM card)
35H8750 E1D Dual CPU Card with
512KB cache
7012/G40 09H4774 System board
09J4713 E4D Dual CPU Card with
512KB cache
09J4714 E4M Mono CPU Card with
512KB cache
07L9397 X4D CPU card, two way
7013/J30 35H8748 C1D Dual CPU Card with 1MB
cache
7013/J40 09J4712 C4D Dual CPU Card with 1MB
cache
7013/J50 07L9397 X4D, 604E CPU card
7015/R30 35H8748 C1D Dual CPU Card with 1MB
cache
7015/R40 09J4712 C4D Dual CPU Card with 1MB
cache
7015/R50 07L9397 X4D, 604E CPU card
C69 7006/41T/41W 12H1281 System board
7006/42T/42W 39H8152 System board
C70 7009/C10 40H5691 CPU card
C72 7006 8184016 MCA I/O Riser Card
C74 7009 12H0304 MCA I/O Riser Card
C75 7006 88G2547 POWER GXT155L adapter
C76 7015/R24 88G0007 CPU planar
C77 7013/59H 8184612 CPU planar
7015/R20
C78 7012/390 88G4006 CPU card
7030/3BT
C79 7012/380 11H3465 CPU card
7030/3AT
C81 7012/380/390/39H 52G4325 System board
7012/397 93H5557 System board
7030/3BT/3AT/3CT 52G4325 System board
C82 7015/R24 52G6071 I/O planar
C83 7013/59H 43G2211 I/O planar
C84 7009 65G7904 I/O planar
C85 7006/41T/41W 12H1281 System board
7006/42T/42W 39H8152
C87 7006 88G2479 POWER GXT150L graphic
adapter
C88 7012/G30 35H8832 System Planar
7012/G40 09J4774
7013/J30/J40 35H8779 SIB System Interface Board
7013/J01 35H8779 (base unit)
7015/R30/R40 40H0421
C89 7013/J01 35H8779 SIB System Interface Board
(expansion unit)
C90 7012/G30 35H8832 System Planar
7012/G40 09J4774
7013/J30/J40/J50 95H0010 MCA planar base unit (MP)
7013/J01 35H8834 MCA expansion planar (MPe)
7015/R30/R40/R50 35H8834 MCA expansion planar (MPe)
C91 7013/J01 35H8834 MCA expansion planar (MPe)
7015/R30/R40/R50
C93 7013/J30/J40/J50 19H0500 Base unit backplane (BP)
7013/J01 19H0325 Expansion unit backplane
C94 59F4581 ARTIC960 1MB packet memory
module
70F9973 ARTIC960 4MB packet memory
module
71G6450 ARTIC960 8MB packet memory
module
43G1796 ARTIC960 16MB packet memory
module
C95 61G2961 ARTIC960 co-processor
platform application
interface board (AIB)
(4-port interface board)
06H4650 ARTIC960 co-processor
platform application
interface board (AIB)
(8-port X.21 AIB)
11H3786 ARTIC960 co-processor
platform application
interface board (AIB)
(8-port EIA-232E AIB)
11H3795 ARTIC960 co-processor
platform application
interface board (AIB)
(6-port V.36 AIB)
C97 53G0632 ARTIC960 AIB 100-pin wrap
plug
33F8995 ARTIC960 EIA-232-D 25-pin
wrap plug
53G0639 ARTIC960 EIA-530-D 25-pin
wrap plug
53G0641 ARTIC960 ISO-4902-D 37-pin
wrap plug
53G0638 ARTIC960 ISO-4903-D 15-pin
wrap plug
06H3357 ARTIC960 8-port X.21 AIB
wrap plug
68F7208 ARTIC960 8-port EIA-232E
AIB wrap plug
72F0168 ARTIC960 6-port V.36 AIB
wrap plug
33F8985 ARTIC960 8-port EIA-232E
cable wrap plug
C98 61G2919 ARTIC960 EIA-232-D shell
cable
61G2924 ARTIC960 EIA-530-D shell
cable
61G2934 ARTIC960 ISO-4902 (V.36)-D
shell cable
61G2929 ARTIC960 ISO-4903 (X.21)-D
shell cable
06H4648 ARTIC960 8-port X.21 cable
71G5053 ARTIC960 8-port EIA-232E
cable
11H3796 ARTIC960 6-port V.36 cable
C99 81F9003 FDDI Network adapter (Type
2-6)
81F9014 FDDI Network adapter (Type
2-7)
43G0855 FDDI Network adapter (Type
2-R)
43G0856 FDDI Network adapter (Type
2-S)
43G0875 FDDI Network adapter (Type
2-T)
43G0876 FDDI Network adapter (Type
2-U)
Cable See note Standard HIPPI cable
(customer supplied)
Note: A short HIPPI cable
suitable for wrap testing
is available. Part Number
90F6492. However, any
standard HIPPI cable up to
25 meters in length will
suffice.
D01 7006 88G2731 .5MB L2 cache (Riser card
with L2 cache)
7009 65G7929 1MB L2 cache (CPU feature
card)
7012/380/390/39H 88G3893 .5MB L2 cache memory module
88G4012 1MB L2 cache memory module
7013/59H 88G3894 .5MB L2 cache memory module
7015/R20 88G3894 .5MB L2 cache memory module
7015/R21
7015/R24 88G4012 1MB L2 cache memory module
7030/3AT3BT/3CT 88G3893 .5MB L2 cache memory module
88G4012 1MB L2 cache memory module
D03 7013/59H 88G3894 0.5MB L2 cache memory
module
7015/R20 88G3894 0.5MB L2 cache memory
module
D04 7009 65G7929 1MB L2 cache memory module
7015/R24 88G4012 1MB L2 cache memory module
D05 7006 88G2731 Riser Card with L2 cache
D06 88G3650 64 Port to 128 Port
Converter kit (four to a
pack).
Note: Converter part number
is 88G3651
D07 7006 Graphics cable
Note: Refer to "Setting the
Display Switches on the
POWER GXT150L Adapter" in
the 7006 Graphics
Workstation Operator Guide
D08 7134 88G5722 DC fan assembly
D09 7012/39H 88G3536 CPU Card
7030/3CT
D10 00F5524 Multiport/2 Interface Cable
Note: If cable has an 8
15F8868 port or 6 port fanout box.
Multiport/2 Synchronous
Interface Cable
D11 88G3717 Ultimedia Video I/O card
(CODEX daughter card)
D15 7011/250 51G8101 System board (66MHz)
8184306 System board (80MHz)
D16 7013/J30/J40 19H0219 Main fan (base unit)
19H0270 Fan asm. only
7013/J50 09J4751 Main fan (base unit)
19H0270 Medium speed fan asm. only
09J4752 High speed fan asm. only
7013/J01 19H0219 Main Fan (expansion unit)
19H0270 Fan asm. only
7015/R30/R40/R50 11H2694 Media Fans
D17 7013/J30/J40/J50 19H0222 MCA Fan Module (base unit)
7013/J01 19H0222 MCA Fan Module (expansion
unit)
7015/R30/R40/R50 11H2694 Media Fans
D18 7013/J30/J40/J50 19H0224 Disk Fan Module (base unit)
19H0270 Fan asm. only
7013/J01 19H0224 Disk Fan Module (expansion
unit)
19H0270 Fan asm. only
D19 7013/J30/J40/J50 39H9222 AC power supply
7015/R30/R40/R50 11H8275 AC power supply
11H2714 DC power supply
D21 7015/R30/R40 11H2686 Disk/CPU/Memory Fan module
7015/R50 93H5822 (rear fan)
D22 7015/R30/R40/R50 11H2694 Media fans
D24 7013/J01 19H0413 Expansion unit power switch
module
D26 7009/C20 40H5693 CPU card
D27 35H8739 NFx memory card without
memory modules
D28 7012/G30/G40 35H8739 NFx memory board
7012/G40 35H8751 NFx memory board (populated
w/64MB memory modules)
7012/G30/G40 35H8694 MRE memory board
7013/J30/J40 35H8739 NFx memory board
D32 35H8694 MRE memory card without
memory module
D33 19H0287 MRE/NFx 8MB memory Jecde
Memory module
D34 19H0288 MRE/NFx 16MB memory Jecde
Memory module
D35 19H0289 MRE/NFx 32MB memory Jecde
Memory module
D37 7013/J30/J40/J50 19H0230 SCSI Interface Card
D40 7012/G30/G40 71F1128 MCA Fans
D41 7012/G30/G40 11H3884 CPU Fans
D45 7012/G40 09J4713 E4D Dual CPU (604) Card
with 512KB Cache
D46 60G1066 Type 3 Media filter
token-ring cable. .254m
(10inch)
60G1063 Standard token-ring cable.
3m (10ft)
D47 52G3380 Enhanced SCSI-2
Differential Fast/Wide
Adapter/A
D49 31F4126 Serial Dual Port Y-cable.
D50 87G1356 Terminator SCSI DE 8-bit
61G8324 Terminator SCSI DE 16-bit
52G4260 Terminator SCSI 50-pin FTP18C
D51 7006 11H8885 GXT500D Graphics Adapter
D52 7012/G40 35H8737 E4M Single CPU (604) Card
D53 7006/42T/42W 39H8152 CPU card
D54 7013/J40 09J4712 C4D Dual CPU (604) Card
7015/R40 with 1MB Cache
D56 12H1204 EIA-232E Printer/ Terminal
Serial Cable
D58 Backup power supply
D61 12H1331 S5.0 base memory card
D62 39H8924 4MB memory card memory
module
D63 39H8925 8MB memory card memory
module
D64 39H8312 32MB memory card memory
module
D66 7250 with S/Ns 11H4436 RSS board (with memory
7250-26-Annnn sockets)
D79 7013/591 39H9200 CPU planar
7015/R21
D81 39H8826 T2 Ethernet Adapter
D82 Generic Ethernet Adapter
39H8826 T2 Ethernet Adapter
39H8817 TP Ethernet Adapter
E00 7012/G30/G40 vendor C4M 604 CPU (1MB L2 cache)
logoed
E01 Generic reference for the
CPU
For type/model and FRU
information refer to FFC
210.
E02 Generic reference for
IO/System Board For
type/model and FRU
information refer to FFC
221.
E03 Generic Ethernet Adapter
type.
E04 Generic Token-Ring Adapter
type
E05 35H8751 64MB Memory module
E09 7012/G40 07L9397 X4D Dual CPU Card w/ 2MB
cache
7013/J50
7015/R50
E25 7013/J series 19H0232 Expansion unit micro
channel bus cable (FXE)
7015/R30/R40/R50 19H0231 Base unit micro channel bus
cable (FXB)
40H0723 Flex cable (For I/O planar
1)
40H0727 Flex cable (For I/O planar
0)
40H0729 Flex cable (to horizontal
conn. on I/O card)
40H0725 Flex cable (to vertical
conn. on I/O card)
Description of the Failing Function Code List
The failing function codes are listed in numerical sequence.
A function may not be physically packaged on the same FRU in different
units. When this condition exists, the FRU part number for each type of
unit is listed.
The columns in the failing function code list are as follows:
Failing Function Code
The failing function code number from the SRN list in Chapter 2.
Machine Type/Model
This column is used when the failing function is on a FRU which
differs by machine type and model. Use the part number for the type
system unit you are servicing. See "Machine Types" in this chapter for
the names of the machine types.
Note:Although the machine cover logo may depict the model number as
four digits, the service and parts ordering system requires
three-digit numbers. For example, if the cover logo depicts
model number 32H, service and parts documentation may refer to
that model as 32H.
Part Number
This column contains the part number of the FRU that contains the
failing function. Use the part number for the type of system unit you
are servicing.
Description and Notes
This column contains the description of the FRU and any usage notes.
The FRU description may be different in different system units. Use
the one for the type of system unit you are servicing.
Updated april 9 2001 by Bruno Croft