____________________________
| System End | Device End |
System End | HD-15 _____|____ HD-15 | Device End
| pin | Signal | pin |
1 |_______|__________|_________| 1
__|__________ | 1 RxD- | TxD- 1 | __________|__
| . . . . . | | 2 RxD+ | TxD+ 2 | | o o o o o |
6-- . . . . . | | 4 RxC- | TxC- 4 | | o o o o o--6
\ . . . . . / | 5 RxC+ | TxC+ 5 | \ o o o o o /
'|-------|' | 6 TxD- | RxD- 6 | '-------|
11 15 | 7 TxD+ | RxD+ 7 | 11
| 9 TxC- | RxC- 9 |
| 10 TxC+ | RxC+ 10 |
| Shell ShGnd | ShGnd |
|_____________|______________|
<=1000ft 28 AWG - max16pF/f - type Belden 9806 or equivalent
>1000ft 24 AWG - max16pF/f - type Belden 9831 or equivalent
__________________
| 128-Port 1|---NB/NC-------.
| Adapter 2|---NB/NC-- | _NB/NC__ _NB/NC _ _NB/NC__
|_______ _| | _|_|_ _|_|_ _|_|_ _|_T_
|||||||__| | |Node1| |Node2| |Node3| |Node4|
| |_____| |_____| |_____| |_____|
|
|
|
| _NB/NC__ _NB/NC _ _NB/NC__
_|_|_ _|_|_ _|_|_ _|_T_
|Node1| |Node2| |Node3| |Node4|
|_____| |_____| |_____| |_____|
____________________________
System End | System End | Device End |
| HD-15 _____|____ HD-15 | Device End
1 | pin | Signal | pin | 1
__|__________ |_______|__________|_________| __________|__
| . . . . . | | 1 RxD- | TxD- 1 | | o o o o o |
6-- . . . . . | | 2 RxD+ | TxD+ 2 | | o o o o o--6
\ . . . . . / | 6 TxD- | RxD- 6 | \ o o o o o /
|-------| | 7 TxD+ | RxD+ 7 | '--------|'
11 15 | Shell ShGnd | ShGnd Shell | 11
|_____________|______________|
<=1000ft 28 AWG - max16pF/f - type Belden 9804 or equivalent
>1000ft 24 AWG - max16pF/f - type Belden 9829 or equivalent
__________________
| 128-Port 1|---ND----------.
| Adapter 2|---ND----- | ___ND___ ___ND___ __ND____
|_______ _| | _|_|_ _|_|_ _|_|_ _|_T_
|||||||__| | |Node1| |Node2| |Node3| |Node4|
| |_____| |_____| |_____| |_____|
|
|
|
| __NB____ __ND__ _ __ND____
_|_|_ _|_|_ _|_|_ _|_T_
|Node1| |Node2| |Node3| |Node4|
|_____| |_____| |_____| |_____|
__________________ _____ _____ _____ _____
| 128-Port 1|____NE___|Modem| _ Telephone line _ |Modem|______NF____|Node1|____|Node2|T
| Adapter 2| |_____| |_____| |_____| |_____|
|_______ _|
||||||||_|
CABLE NE CABLE NF
_________________________________ _________________________________
| | | |
| System End | Modem End | | Modem End | Ran End |
| HD-15 Male | DB-25 Male | | DB-25 Male | HD-15 Female |
| Signal | Signal | | Signal | Signal |
|________________|________________| |________________|________________|
| | | |
| RxD 1 _______________ 3 RxD | | RxD 3 _______________ 6 RxD |
| | | |
| RxC 4 _______________ 17 RxC | | RxC 17 _______________ 9 RxC |
| | | | | |
| * | | * |
| 5 _______| | | |_____ 10 |
| | | |
| TxD 6 _______________ 2 TxD | | TxD 2 _______________ 1 TxD |
| | | |
| TxC 9 _______________ 15 TxC | | TxC 15 _______________ 4 TxC |
| | | | | |
| * | | * |
| 10 ______| | | |_____ 5 |
| | | |
| SG 12 _______________ 7 SG | | SG 7 _______________ 12 SG |
| | | |
| FGND Shell _______ Shell,1 FGND | | FGND Shell,1 _______ Shell FGND |
| | | |
| ___ 4 | | 4 ___ |
| | | | | |
| * 2200pf Capacitor |___ 6 | | 6 ___| |
| | | | | |
| |___ 20 | | 20 ___| |
|_________________________________| |_________________________________|
* = 2200pf Capacitor
System End Modem End
1
__|__________ 1 Male DB-25 13
| . . . . . | _|_______________________|_
6-- . . . . . | | . . . . . . . . . . . . . |
\ . . . . . / \ . . . . . . . . . . . . /
|--------' |_____________________|
11 14 25
1 Modem End 13
_|_______________________|_
| . . . . . . . . . . . . . | RAN End
\ . . . . . . . . . . . . / 1
|_____________________| __|__________
14 Male DB-25 25 | o o o o o |
6-- o o o o o |
\ o o o o o /
|_______|
11 15
Up to 100ft - 24 AWG - max12.5pF/f - type Belden 9929 or equivalent
Controller line baud rates of 19.2 Kbps or less recommended.