100Mbps Token-Ring PCI Adapter
Type 9-Y #4959

    AIX fileset: devices.pci.14103e00
Microcode Update
_____________________ 9-pin | FRU 09P4146 #4959 | D-Shell | 00P1476 #4959 | | 03N3554 | | | RJ-45 | | Connector | _ _ _ ___| |_| |||| |||||| ||| - Automatic ring speed selection 100, 16, 4 Mbps - Half or Full Duplex C A B L I N G FRU Length Description Adapter end to network end -------------------------------------------------------- 6339098 9pos D-Shell male to STP 04H7648, Wrap plug for diagnostics 6165899. Connector View __________ | | | | Amber LED | O O | Green LED | | | _ | | / | | | | o| | | |oo| | | |oo| | 15-pos Connector 10Base5 | |oo| | | | o| | | \_| | | | | | | | | ______ | | | ___ | | | | | || | RJ-45 Connector 10BaseT | || || | | | |___|| | | |______| | | | | | | | | | | 9-Y | | | |__ o __| | | |____| Amber Green Blinkink Blinkink The adapter is waiting for initialization Off Off The adapter initialization is in progress or the system unit is powered off. Off Blinkink The adapter did not detect any problems during its self-diagnostic tests and is waiting to open. Off On The adapter is opene and operating correctly On Off The adapter self-diagnostic tests failed Blinkink Off The adapter is closed. One of the following condition exists. - The adapter open failed - The adapter detect a wire fault - The adapter failed the auto-removal test. Blinkink On The adapter has detected beaconing or a hard error. On On THe adapter has failed Created 10/13/99 Last Update: Mar 2004 by BJ Croft