___________________________________________
| | |
B2 --> | B2 Internal connector #6218 | |
Green light --> | | |
B1 --> | B1 Internal connector | |
| | |
A2 --> | 96H9875<-32H3836 (without DRAM) | |
Green light --> | 73G3233 DRAM card | |
A1 --> | ___ ___________|_|
|__| |____________||__|||||||
|
Status: Still supported but withdraw - #6215 4-n now replaces #6218 4-j
Status of light
Off Both link inactive / DISK failing / link
ON Both link active
Slow Flash Only 1 SSA link active
The adapter card has 4 SSA connectiors that are arranged in 2 pairs.
Connectors A1 and A2 are one pair; connectors B1 and B2 are the other pair.
The SSA links must be configured as loops. Each loop is connected to a pair of
connectors at the SSA card. These connectors MUST be a valid pair ( that is,
configured, and the diagnostics fail. Operations to all the disk drive modules
on a particular loop can continue if that loop breaks at any one point.
This adapter also contains ARRAY MANAGEMENT SOFTWARE that provides RAID-5
functions to control the arrays of the RAID subsystem. An array can have from
3 to 16 member disk drives. Each array is handled as ONE LARGE DISK by the
operating system. The array management software translate requests to this
large disk into requests to the member disk drive. Although this adapter is a
RAID adapter, it can be configured so that all, some, or none of the disk
drives that are attached to it are member disks of arrays.
SSA Cables:
P/N FC Length
07H9163 5002 0.18m 0.6ft
31H7960 5006 0.6m 1.9ft
07H8985 5010/2895 1.0m 3.3ft
32H1465 5025/2896 2.5m 8.2ft
88G6404 5050/2897 5m 16.4ft
32H1466 5100/2898 10m 32.8ft
88G6406 5250/2899 25 82.0ft
93H9821 Internal - plugs on B1/B2
07H9153 5500 Extender Pair
32H7048 Extender 1 cable
32H7049 Wrap for externder
INTERNAL CABLING: Ports B1 and B2 have 2 sets of connectors. There is an
internal B1/B2 pair and an external B1/B2 pair. Only one pair of
these loops connector can be used at a time.
Updated: Nov 30 2000 by Bruno Croft