1.0 Microcode Change History:
 
005f
-Virtual SES code fix (SF2, L4). 
1) (SF2, L4) I2C bus may hang when adapter reset occurs while the adapter is reading the EEPROM on the I2C bus.  Reduce window of occurrence.
2) (L4).  I2C bus timeout when adapter is reset and running diagnostics.
-SCSI RAID fix.
1) Fix for Adapter Unit Check when Fast/Write Cache not operational (e.g. bad battery, bad NVRAM stick).
2) Added Notification of battery/charger not working.
3) Enhanced error log for Read Cache error .
4) Change in cache implementation from Stack (LIFO) to Queue (FIFO).
005d
-Virtual SES fixes:  a) LED fix for L4 system and b) PCI-X Quad Channel Ultra320 SCSI RAID Adapter fix for all systems
-Error log changes:  a) Differentiated a error condition.  Adapter now logs a specific error instead of generic for a given situation. b) Return the correct error information to the pSeries Adapter Device Driver (ADD) so a SCSI adapter detected CRC error is logged instead of a program error microcode problem. Problem was seen on L4, SF2 and SF4.
-Added Linux support features and fixed Linux drive replacement problem
-Force SE mode to 20MBps when an SE device is connected to the 7029-6C3/6E3 new feature backplane.  This backplane expands the Integrated SCSI Controller adding an external port.
0059
External SE device fix;  external SE devices are limited to 20MBps.
Added support for unique vendor command on 3580/3583 LTO tape device.
Modification to run Ultra320 speeds using Linux kernel 2.6.
Various performance enhancements.
0051
Resolves SCSI_ERR10 (SCSI Bus Reset) condition upon Diagnostic's System Verification or Microcode Download in 7028-6C1 w/ safte device.
004d
Enhanced SCSI signal path validation.
Removed extended Target Mode delays.
Removed erroneous AIX errors logged during drive microcode download.
Added unique RAID array identifiers for Linux support.
Removed erroneous SCSI bus reset error logged when a device reports an error condition.
Corrected extended SCSI bus reset that may occur when running HACMP.
0042
Installing two 4-pack backplanes in a p615 may cause the second backplane (sesX) to boot in the defined state or not be seen.  Microcode 0042 corrects this problem.
002f
GA level

Note:  In order for Ultra320 to function properly a minimum level of microcode is required for the DASD.  These are listed below

Drive Type
Microcode Level (Hex)
Microcode level (ASCII as appears in VPD)
Cheetah73LP (9GB)
C54E 43353445
Cheetah73LP (18GB+)
C50E 43353045
Cheetah146LP C50F 43353046
Cheetah73LP-X15 C51A 43353141
Ultrastar73 S5DE 53354445
US146Z10 S28C 53323843

 

2.0.0 General information

SUBJECT: PCI-X Dual Channel Ultra320 SCSI RAID Adapter

******* PLEASE READ THIS ENTIRE NOTICE *********


2.0.1 Installation Time:
     Approximately 30 minutes
 
2.0.2 Machine's Affected:
     7028-6C1/6E1,6C4/6E4
     7029-6C3/6E3
     7038-6M2
     7039-651     
     7040-671/681/61D/61R
     7311-D10/D20
     9111-520
     9112-265
     9114-275
     9117-570
     9124-550/720
     9406-520/550/750   

2.0.3 AIX Requirements:
      For support:  AIX 5.1 ML_04 or AIX 5.2 ML_01
      For U320 support:  AIX 5.1 ML_05 or AIX 5.2 ML_02 along w/ the aforementioned minimum DASD microcode requirements.

3.0 Determine the Current Microcode Level:

Before you install the microcode, it is important to determine the microcode level of the Adapter installed in the target system. Use
the following instructions to read the ROM level stored in the Adapter's VPD.
1)  List the SCSI RAID Adapters installed in the system by typing:
    lsdev -C | grep sisraid
Note: All of the SCSI RAID initiators addresses that are installed will bedisplayed. The names will be sisioaX, where X is 0, 1, etc.
2) To check the current microcode level for the adapter or controller enter the following command
   lscfg -vl sisraidX
Where X is the number/s of the previous command. The Command will produce output similar to
    DEVICE       LOCATION         DESCRIPTION
 sisraid0          U0.1-P1-I5  PCI-X Ultra320 SCSI RAID Adapter

PCI-X Dual Channel Ultra320 SCSI RAID Adapter:
Part Number.................97P2702
FRU Number..................97P2702
Serial Number...............YL1093175020
Manufacture ID..............0009
EC Level....................0
ROM Level.(alterable).......0309002f
Product Specific.(Z0).......5703
Product Specific.(Z1).......1
Device Specific.(YL)........U0.1-P1-I5


If the ROM Level is less than XXXX005f then you should update the microcode.

4.0.1 Downloading and Unpacking the Firmware Update Package from CORE

NOTE:  The CORE image will now be the RPM Format File.

1) After downloading the files from CORE on to your personal system find the file "sisraid.005f.rpm" in the CORE desintation directory.
2) Log in to the Target Server
3) Create a directory, if not already there (mkdir /tmp/microcode/RPM)
4) Transfer the file to the Target Server "/tmp/microcode/RPM directory" using ftp or another method.
5) Unpack the RPM file by using the following command:  "rpm -ihv ignoreos sisraid.005f.rpm

4.0.2 Downloading the RPM Format File to the Target Server
Use this method to download to an AIX system:

Note: The instructions that follow are specific AIX commands. AIX commands are CASE (lower and upper) SENSITIVE, and must be entered exactly as shown, including filenames.

a) Make a directory on an AIX system to receive the RPM format file.
    Enter:      mkdir /tmp/microcode/RPM

b) Transfer the RPM format file to the /tmp/microcode directory (using "Save as ...").
    You'll see the filename is sisraid.005f.rpm

c) Unpack the file by executing the instructions below:
    Enter the commands:
        rpm -ihv --ignoreos sisraid.005f.rpm

The microcode files will be added to /etc/microcode/
 

4.0.3 Downloading File from the Microcode CD-ROM

Copy microcode updates from the CD-ROM to standard locations on your local disk:

1. RPM packaged microcode files will be copied to "/tmp/microcode/RPM"
2. Unpack the file by executing the instructions below:
    Enter the commands:
        rpm -ihv --ignoreos sisraid.005f.rpm
3. Microcode files will be copied to "/etc/microcode". 

Notes:

 - "/etc/microcode" is a symbolic link to "/usr/lib/microcode".
 - If permission does not allow the copy to the above stated directory
                  or file then the user will be prompted for a new location.
 

5.0 Microcode Download Procedure-PCI-X Dual Channel Ultra320 SCSI RAID Adapter

NOTE: Microcode download must be performed seperately for each Adapter under distinct Logical Partitions (LPAR's).
              Please save current and older versions of the microcode update files in case you need to restore your system.

NOTE: Microcode Download CAN be performed concurrently.

Installation Time:  Approximately 30 min System Time.

Please verify the file size and checksum of the raw microcode files in /etc/microcode/.  See step 10H.
Filesize:  1025172
Checksum:  01420

Procedure:
1. Stop all applications.
2. Enter diag
3. Select the "Task Selection" from diagnostics menu.
4. Select "Microcode Download" from "Task Selection" menu.
5. Select all of the PCI-X Dual Channel Ultra320 SCSI RAID Adapters that needs to be updated from the list of devices by pressing "Enter".  The devices will be displayed as sissioa#, where # is the number of the device.  Press "F7".
6. A diaglogue box will be displayed on screen.  Press "Enter" to continue.
7. Select "/etc/microcode".
8. A dialogue box will may be displayed on screen.  It will state that the current microcode level on the adapter is not in the /etc/microcode directory.  This is acceptable as you will be flashing new microcode onto the adapter.  Also, incorrect code will automatically be rejected.  Press "Enter" to continue.
9. An "M" will be displayed next to the latest level of microcode in the /etc/microcode directory.  Select that level and press "Enter".
10. The following message will appear on the screen when download is completed: "Microcode download complete successfully.  The current microcode level for the device sisscsia# is .....  Please run diagnostics on the adapter to ensure that it is functioning properly."  DO NOT run diagnostics on the device at this time.
11. Exit diagnostics.
 

12. For systems that have LPAR installed, the microcode file must be placed on all partitions that have a SCSI RAID device in order to update the code.  Follow this procedure for each partition:

    A.  Log into the target partition.
    B.  Type: cd /etc/microcode
    C.  FTP to the partition that has the media bay assigned. (ie.  ftp partition1.ibm.com)
    D.  Type: cd /etc/microcode
    E.  Type: bin
    F.  Type: get 5052414D.0309005f
    G.  Type: quit
    H.  Verify the filesize and checksum of the file by typing:
            1) Filesize:  "ls -l 
5052414D.0309005f".  The filesize should be 1025172.
            2) Checksum:  "sum 5052414D.0309005f".  The checksum should be 01420.
    I.   Follow the above procedure to download the microcode to all PCI-X Dual Channel Ultra320 SCSI RAID Adapter' in the partition.

 

13. Verify the code level is 005f by typing "lscfg -vl sisraid#" for each scsi device updated. <Where # is the number sisraid device>