IBM
pSeries
DATE: Nov 17, 2003
Table of Contents
2.0.0 General Information
2.0.1 Installation Time
2.0.2 Machine's Affected
3.0 Determine the Current Microcode Level
4.0.0 Downloading and Unplacking the Firmware
Update Package from the WEB
4.0.1 Downloading and Unpacking the Firmware Update
Package from CORE
4.0.2 Downloading the RPM Format File to the Target
Server
4.0.3 Downloading File from the Microcode CD-ROM
5.0 Microcode Download Procedure-PCI-X Dual Channel Ultra320 SCSI RAID Adapter
=====================================================================================
0042 |
Installing two 4-pack backplanes
in a p615 may cause the second backplane (sesX) to boot in the defined
state or not be seen. Microcode 0042 corrects this problem. |
Drive Type |
Microcode Level (Hex) |
Microcode level (ASCII as
appears in VPD) |
Cheetah73LP (9GB) |
C54E | 43353445 |
Cheetah73LP (18GB+) |
C50E | 43353045 |
Cheetah146LP | C50F | 43353046 |
Cheetah73LP-C15 | C51A | 43353141 |
Ultrastar73 | S5DE | 53354445 |
US146Z10 | S28C | 53323843 |
SUBJECT: PCI-X Dual Channel Ultra320 SCSI RAID Adapter
******* PLEASE READ THIS ENTIRE NOTICE *********
2.0.1
Installation Time:
Approximately 30 minutes
2.0.2
Machine's Affected:
7028-6C4/6E4
7029-6C3/6E3
7038-6M2
7039-651
7040-671/681/61D/61R
7311-D10/D20
9112-265
9114-275
3.0 Determine the Current Microcode Level:
Before you install the microcode, it is important to determine the microcode level of the Adapter installed in the target system. Use
the following instructions to read the ROM level stored in the Adapter's VPD.
1) List the SCSI RAID Adapters installed in the system by typing:
lsdev -C | grep sisioa
Note: All of the SCSI RAID initiators addresses that are installed will bedisplayed. The names will be sisioaX, where X is 0, 1, etc.
2) To check the current microcode level for the adapter or controller enter the following command
lscfg -vl sisioaX
Where X is the number/s of the previous command. The Command will produce output similar to
DEVICE LOCATION DESCRIPTION
sisioa0 U0.1-P1-I5 PCI-X Ultra320 SCSI RAID Adapter
PCI-X Dual Channel Ultra320 SCSI RAID Adapter:
Part Number.................97P2702
FRU Number..................97P2702
Serial Number...............YL1093175020
Manufacture ID..............0009
EC Level....................0
ROM Level.(alterable).......0309002f
Product Specific.(Z0).......5703
Product Specific.(Z1).......1
Device Specific.(YL)........U0.1-P1-I5
If the ROM Level is less than XXXX0042 then you should update the microcode.4.0.0 Downloading and Unpacking the Firmware Update Package from the WEB
b) Transfer the AIX format file to the /tmp/microcode directory
(using "Save as ...").
You'll see the filename is sisraid0042.bin
c) Unpack the file by executing the instructions below. You will be
asked for the password from the license agreement.
Enter the commands:
cd /tmp/microcode
chmod +x sisraid0042.bin
./sisraid0042.bin
[Don't overlook the periods (.) in the above command.]
The directory sisraid0042 with these files will be added to
/tmp/microcode.
1) 5052414D.03090042 (Microcode Image)
Enter the following command to copy the microcode files to "
/etc/microcode " directory :
cp /tmp/microcode/sisraid0042/5052414D.03090042 /etc/microcode
Enter the following commands to copy these file onto a diskette:
ls /etc/microcode/5052414D.03090042 | backup -i -v -f/dev/rfd0
This will produce AIX backup diskettes. Label the diskettes:
"PCI-X Dual Channel Ultra320 SCSI RAID Adapter"
4.0.1 Downloading and Unpacking the Firmware Update Package from CORE
With the machine powered ON and AIX operational but no activity,
perform the following steps to install the FLASH code into the
SCSI RAID Adapter.
1. Insert diskette with the file downloaded from CORE into the floppy diskette drive of the Media Bay.
NOTE: If the system is running LPAR, you must determine what partition has the media bay assigned.
How to determine what partition has the
diskette drive assigned when running LPAR:
A. Log onto the Hardware
Management Console (HMC).
B. On the opening
screen, in the Navigation Area, select Partition Management.
C. In the Partition
Management window, right-click on the top device listed in the
window. Select Properties.
D. Select the IOSLOT tab.
E. In the IOSLOT field,
find the SCSI initiator named PCI-X Dual Channel Ultra320 SCSI RAID
Adapter .
F. Click on the + sign
next to the I/O Group associated with the PCI-X
Dual Channel Ultra320 SCSI RAID
Adapter.
This will display the partition associated
with the diskette drive.
2. Log into the target system (or LPAR that has the media bay assigned) as root.
3. Type: restore
4.0.2 Downloading the RPM Format File
to the Target Server
Use this
method to download to an AIX system:
Note: The instructions that follow are specific AIX commands. AIX commands are CASE (lower and upper) SENSITIVE, and must be entered exactly as shown, including filenames.
a) Make a
directory on an AIX system to receive the RPM format file.
Enter: mkdir /tmp/microcode/RPM
b) Transfer the
RPM format file to the /tmp/microcode directory (using "Save as ...").
You'll see the filename is sisraid.0042.rpm
c) Unpack the file by executing the instructions below:
Enter the commands:
rpm -ihv --ignoreos
sisraid.0042.rpm
The microcode files will be added to /etc/microcode/
4.0.3 Downloading File from the Microcode CD-ROM
Copy microcode updates from the CD-ROM to standard locations on your local disk:
1. RPM packaged microcode files will be copied to
"/tmp/microcode/RPM"
2. Unpack the file by executing the instructions below:
Enter the commands:
rpm -ihv --ignoreos sisraid.0042.rpm
3. Microcode files will be copied to "/etc/microcode".
- "/etc/microcode" is a symbolic link to "/usr/lib/microcode".
- If permission does not allow the copy to the above stated
directory
or file then the user will be prompted for a new location.
5.0 Microcode Download Procedure-PCI-X Dual Channel Ultra320 SCSI RAID Adapter
NOTE: Microcode download must be performed
seperately for each Adapter under distinct Logical Partitions
(LPAR's).
Please save current and older versions of the microcode update files in
case you need to restore your system.
NOTE: Microcode Download CAN be performed concurrently.
Installation Time: Approximately
30 min System Time.
Please verify the file size and checksum of the raw microcode files
in /etc/microcode/. See step 10H.
Filesize: 1019232
Checksum: 33164
Procedure:
1. Stop all applications.
2. Enter diag
3. Select the "Task Selection" from diagnostics menu.
4. Select "Microcode Download" from "Task Selection"
menu.
5. Select the PCI-X Dual Channel Ultra320 SCSI RAID
Adapter
that needs to be updated from the list of devices.
6. Select filesystem.
NOTE: If this level of ucode is already installed
in the backplane you will receive a message that will let you know. A
message may also be displayed if the /etc/microcode directory does not
have the
previous level microcode. This is true and is not required to complete
the
download. Hit enter to continue.
7. The following message will
appear on the screen when download is completed: "The microcode
download has completed successfully, run diagnostics on the SES
device". Please ignore the "run diagnostic" message and do NOT run
diagnostics on the SES device at this time.
8. Return to the Tasks Selection menu and repeat this
procedure for each SES that requires this microcode.
9. Exit diagnostics.
10. For systems that have LPAR installed, the microcode file must be placed on all partitions that have a SES device in order to update the code. Follow this procedure for each partition:
A. Log into the
target partition.
B. Type: cd
/etc/microcode
C. FTP to the partition
that has the media bay assigned. (ie. ftp partition1.ibm.com)
D. Type: cd
/etc/microcode
E. Type: bin
F. Type: get 5052414D.03090042
G. Type: quit
H. Verify the filesize
and checksum of the file by typing:
1) Filesize:
"ls -l 5052414D.03090042". The filesize should
be 1019232.
2) Checksum: "sum 5052414D.03090042". The checksum should be 33164.
I. Follow the above procedure to
download the microcode to all PCI-X Dual Channel Ultra320 SCSI RAID
Adapter'
in the partition.
11. Verify the code level is 0042 by typing "lscfg -vl sisioa#" for each scsi device updated. <Where # is the number sisscsia device>