IBM
eServer
DATE: Feb 20, 2006
Table of Contents
2.0 General Information
2.1 Installation Time
2.2 Machine's Affected
2.3 AIX Requirements
2.4 Linux Requirements
3.0 Determine the Current Microcode Level for AIX
3.1 Determine the Current Microcode Level for
Linux
4.0 Downloading
and Unpacking the Firmware Update
Package from CORE
4.1 Downloading the RPM Format File to the Target
Server
4.2 Discovery Tool Microcode CD-ROM creation and download
instructions
5.0 Verifying microcode before download and notes
5.1 Microcode Download Procedure-PCI-X Dual
Channel Ultra320 SCSI RAID Adapter for AIX
5.2 Microcode Download Procedure-PCI-X Dual
Channel Ultra320 SCSI RAID Adapter for Linux (SLES 9 SP1, RHEL4 and
above)
5.3
Microcode Download Procedure-PCI-X Dual
Channel Ultra320 SCSI RAID Adapter for Linux (SLES 9 base, RHEL3 and
prior)
=====================================================================================
0509007e |
-Dual-Initiator (HA) mode fixes: A) Adapter transition timing window shortened for non-SCSI RAID adapters (fix for CCIN 5702, 571A) B) Modification to cache flushing algorithm, fix for the below. 1) A Stand Alone SCSI RAID adapter (that is not the preferred Primary) is full of cache data that will take a long time to flush. 2) Power on a second SCSI RAID that is the preferred Primary. 3) When the failover happens the first SCSI RAID will not have finished flushing cache data before the second IOA starts talking to the drives that the first IOA is still flushing data to (CCIN 5703 & 571B) -Added NACA support (all U320 SCSI Controllers/Adapters) |
0509007a | Fixes for SCSI RAID HA (Dual Initiator) mode. This will be the first acceptable microcode level for SCSI RAID HA. |
0509006d |
-Contains fix for HUS10K DASD Selection Timeouts which can cause a boot drive not to be found and the system to boot to SMS. -Error log entry w/ PRC 14005060 can appear in pSeries SCSI RAID HA
environments during random system boots. |
05090066 |
Do not install this level. Configuration Problems w/ HUS10K DASD. -New revision level of microcode. -Added microcode support for SCSI RAID HA mode (device driver support in Oct 2005 release of AIX). As part of this, the sisraid location code has changed. See the below example. Changes in Red.
-Ported 20MBps SE fix to new revision level. -Fixed FCode bug which caused BA090003 sysplanar errors to be logged during boot from a rootvg SCSI RAID array. NOTE: Some sysplanar errors may get logged after downloading this level of microcode. Review of the timestamp will reveal that these errors are from a prior boot. Clear the errorlog ("errclear 0") after downloading the microcode to prevent future improper logging of this error. |
0309006a | -Added detection for invalid DMA's. This
DMA issue represents a potential data error. IBM recommends that you
install this fix immediately. -Cache Data Boundary modifications |
03090068 |
-Minimum support level for HV
products -Increased BATs speed (Adapter/Controller comes available faster on bringup) -Added support for HV products -Alterations to the SCSI RAID cache page tables -Alterations to SCSI RAID cache flushing routine including increased drain speed -Support for increased cache size from 16MB to 40MB in SCSI RAID Enablement Card |
03090061 |
Prior to microcode update, a
shutdown is performed to the I2C bus to acquiesce activity. This
prevents the I2C bus from getting hung and the Virtual SES devices from
coming up "defined". |
0309005f |
-Virtual SES code fix (SF2,
L4). 1) (SF2, L4) I2C bus may hang when adapter reset occurs while the adapter is reading the EEPROM on the I2C bus. Reduce window of occurrence. 2) (L4). I2C bus timeout when adapter is reset and running diagnostics. -SCSI RAID fix. 1) Fix for Adapter Unit Check when Fast/Write Cache not operational (e.g. bad battery, bad NVRAM stick). 2) Added Notification of battery/charger not working. 3) Enhanced error log for Read Cache error . 4) Change in cache implementation from Stack (LIFO) to Queue (FIFO). |
0309005d |
-Virtual SES fixes: a) LED
fix for L4 system and b) PCI-X Quad Channel Ultra320 SCSI RAID Adapter
fix for all systems -Error log changes: a) Differentiated a error condition. Adapter now logs a specific error instead of generic for a given situation. b) Return the correct error information to the pSeries Adapter Device Driver (ADD) so a SCSI adapter detected CRC error is logged instead of a program error microcode problem. Problem was seen on L4, SF2 and SF4. -Added Linux support features and fixed Linux drive replacement problem -Force SE mode to 20MBps when an SE device is connected to the 7029-6C3/6E3 new feature backplane. This backplane expands the Integrated SCSI Controller adding an external port. |
03090059 |
External SE device fix;
external SE devices are limited to 20MBps. Added support for unique vendor command on 3580/3583 LTO tape device. Modification to run Ultra320 speeds using Linux kernel 2.6. Various performance enhancements. |
03090051 |
Resolves SCSI_ERR10 (SCSI Bus Reset) condition upon Diagnostic's System Verification or Microcode Download in 7028-6C1 w/ safte device. |
0309004d |
Enhanced SCSI signal path
validation. Removed extended Target Mode delays. Removed erroneous AIX errors logged during drive microcode download. Added unique RAID array identifiers for Linux support. Removed erroneous SCSI bus reset error logged when a device reports an error condition. Corrected extended SCSI bus reset that may occur when running HACMP. |
03090042 |
Installing two 4-pack backplanes
in a p615 may cause the second backplane (sesX) to boot in the defined
state or not be seen. Microcode 0042 corrects this problem. |
0309002f |
GA level |
Drive Type |
Microcode Level (Hex) |
Microcode level (ASCII as
appears in VPD) |
Cheetah73LP (9GB) |
C54E | 43353445 |
Cheetah73LP (18GB+) |
C50E | 43353045 |
Cheetah146LP | C50F | 43353046 |
Cheetah73LP-X15 | C51A | 43353141 |
Ultrastar73 | S5DE | 53354445 |
US146Z10 | S28C | 53323843 |
SUBJECT: PCI-X Dual Channel Ultra320 SCSI RAID Adapter
******* PLEASE READ THIS ENTIRE NOTICE *********
2.1
Installation Time:
Approximately 30 minutes
2.2
Machine's Affected:
7028-6C1/6E1,6C4/6E4
7029-6C3/6E3
7038-6M2
7039-651
7040-671/681/61D/61R
7311-D10/D20
9110-510
9111-285/520
9112-265
9113-550
9114-275
9115-505
9117-570
9118-575
9119-590/595
9123-710
9124-720
9131-52A
9133-55A
9406-520/550/750
2.3
AIX Requirements:
For
support: AIX 5.1 ML_04 or AIX 5.2 ML_01
For U320 support: AIX 5.1
ML_05, AIX 5.2 ML_02, AIX 5.3 or above along w/ the aforementioned minimum
DASD
microcode requirements.
2.4
Linux Requirements:
For support: SLES 8
SP3 or RHEL 3 U1 or above
3.0 Determine the Current Microcode Level for AIX:
Before you install the microcode, it is important to determine the microcode level of the Adapter installed in the target system. Use
the following instructions to read the ROM level stored in the Adapter's VPD.
1) List the SCSI RAID Adapters installed in the system by typing:
lsdev -C | grep sisioa
Note: All of the SCSI RAID initiators addresses that are installed will be displayed. The names will be sisioaX, where X is 0, 1, etc.
2) To check the current microcode level for the adapter or controller enter the following command
lscfg -vl sisioaX
Where X is the number/s of the previous command. The Command will produce output similar to
DEVICE LOCATION DESCRIPTION
sisioa0
U0.1-P1-I5 PCI-X Ultra320 SCSI RAID Adapter
PCI-X Dual Channel Ultra320 SCSI RAID
Adapter:
Part
Number.................97P2702
FRU
Number..................97P2702
Serial
Number...............YL1093175020
Manufacture
ID..............0009
EC Level....................0
ROM
Level.(alterable).......0309002f
Product
Specific.(Z0).......5703
Product Specific.(Z1).......1
Device
Specific.(YL)........U0.1-P1-I5
If the ROM Level is less
than 0509007e then you should update the microcode.
3.1 Determine the Current Microcode Level for Linux:
RHEL 3:
1) To list the scsi initiators Type: "ls /proc/scsi/ipr"
If the Firmware Version is less
than 0509007e then you should update the microcode.
4.0 Downloading and Unpacking the Firmware Update Package from CORE
NOTE: The CORE image will now be the RPM Format File.4.1 Downloading the RPM Format File
to the Target Server
Use this
method to download to an AIX or Linux system:
Note: The instructions that follow are specific AIX/Linux commands. AIX/Linux commands are CASE (lower and upper) SENSITIVE, and must be entered exactly as shown, including filenames.
1) Make a
directory on an AIX/Linux system to receive the RPM format file.
Enter: "mkdir /tmp/microcode"
Enter:
"mkdir /tmp/microcode/RPM"
2) Transfer the
RPM format file to the /tmp/microcode/RPM directory (using "Save as ...").
Change to that directory, "cd /tmp/microcode/RPM".
You'll see the
filenames for the RPM files.
A) For AIX,
SLES9 base, RHEL3 & prior,
the filename is pci.1069B166.09-0509007e-1.aix5.1.noarch.rpm
B) For SLES9 SP1,
RHEL4 & above,
the filename is pci.1069B166.09-0509007e-1.Linux.noarch.rpm
3) Unpack the file by executing the instructions
below:
A) For AIX,
SLES9 base, RHEL3 & prior,
type "rpm -ihv --ignoreos
pci.1069B166.09-0509007e-1.aix5.1.noarch.rpm"
B) For SLES9
SP1, RHEL4 & above,
type "rpm -ihv --ignoreos
pci.1069B166.09-0509007e-1.Linux.noarch.rpm"
4a) For AIX, SLES9 base,
RHEL3 & prior:
The microcode files will be added to /usr/lib/microcode/.
4b) For SLES9 SP1, RHEL4
& above:
The microcode files will be added to /lib/firmware/.
4.2 Discovery Tool Microcode CD-ROM creation and download instructions
To obtain information how to burn a
CD-ROM and run the Discovery Tool for an AIX System please go to: CDROMhelp.html
1) After running the Discovery Tool successfully the "/tmp/microcode/RPM"
directory was created and your rpm files are copied from the CD-ROM.
2) Change to that directory, "cd /tmp/microcode/RPM".
3) Unpack the file by executing the instructions below:
Enter the commands:
rpm -ihv --ignoreos
pci.1069B166.09-0509007e-1.aix5.1.noarch.rpm
4) Microcode files will be copied to "/etc/microcode". The file
size and checksum of the microcode image will be verified in Section
5.0
Notes:
- "/etc/microcode" is a symbolic link to "/usr/lib/microcode".
- If permission does not allow the copy to the above stated
directory
or file then the user will be prompted for a new location.
5.0 Verifying microcode before download and notes
NOTE: Microcode download must be performed
separately for each Adapter bus under distinct Logical Partitions
(LPAR's).
Please save current and older versions of the microcode update files in
case you need to restore your system.
NOTE: Microcode Download CAN be performed concurrently.
Installation Time: Approximately 30 min System Time.
Please verify the file size and checksum of the raw microcode files
matches the below.
Filesize: 1250896
Checksum: 45913
For AIX, SLES9 base, RHEL3
& prior: "ls -l /usr/lib/microcode/5052414D.0509007e" to
verify Filesize.
"sum /usr/lib/microcode/5052414D.0509007e"
to verify Checksum.
For SLES9 SP1, RHEL4 &
above: "ls
-l /lib/firmware/pci.1069B166.09.0509007e"
to
verify Filesize.
"sum /lib/firmware/5052414D.0509007e" to
verify Checksum.
For systems that have LPAR installed, the microcode file must be placed on all partitions that have a SCSI device in order to update the code. Follow this procedure for each partition:
For AIX,
SLES9 base, RHEL3 & prior:
A) Log into the
target partition.
B) Type: "cd /usr/lib/microcode"
C) FTP (for AIX)
or SFTP (for Linux) to the partition
that has the media bay assigned. (ie. ftp/sftp partition1.ibm.com)
D) Type: "cd /usr/lib/microcode"
E) If using FTP
then Type: "bin"
F) Type: "get 5052414D.0509007e"
G) Type: "quit"
For SLES9
SP1, RHEL4 & above:
A) Log into the
target partition.
B) Type: "cd
/lib/firmware"
C) SFTP to the
partition
that has the media bay assigned. (ie. "sftp partition1.ibm.com")
D) Type: "cd /lib/firmware"
E) Type: "get pci.1069B166.09.0509007e"
F) Type: "quit"
5.1 Microcode Download Procedure-PCI-X Dual Channel Ultra320 SCSI RAID Adapter for AIX
Procedure: