IBM
pSeries
DATE: Mar 19th, 2004
Table of Contents
2.0.0 General Information
2.0.1 Installation Time
2.0.2 Machine's Affected
3.0 Determine the Current Microcode Level
4.0.0 Downloading and Unplacking the Firmware
Update Package from the WEB
4.0.1 Downloading and Unpacking the Firmware Update
Package from CORE
4.0.2 Downloading the RPM Format File to the Target
Server
4.0.3 Downloading File from the Microcode CD-ROM
5.0 Microcode Download Procedure-PCI-X Dual Channel Ultra320 SCSI Adapter bus
=====================================================================================
0049 |
Enhanced SCSI signal path
validation. Removed extended Target Mode delays. Removed erroneous AIX errors logged during drive microcode download. Added unique RAID array identifiers for Linux support. Removed erroneous SCSI bus reset error logged when a device reports an error condition. Corrected extended SCSI bus reset that may occur when running HACMP. |
0041 |
Installing two 4-pack backplanes
in a p615 may cause the second backplane (sesX) to boot in the defined
state or not be seen. Microcode 0041 corrects this problem. |
0039 |
Enables Ultra 320 support |
0018 | This level removes erroneous SCSI_ERR_10 errors at boot and runtime and allows for internal Hot Swap. |
0005 | GA level |
Drive Type |
Microcode Level (Hex) |
Microcode level (ASCII as
appears in VPD) |
Cheetah73LP (9GB) |
C54E | 43353445 |
Cheetah73LP (18GB+) |
C50E | 43353045 |
Cheetah146LP | C50F | 43353046 |
Cheetah73LP-X15 | C51A | 43353141 |
Ultrastar73 | S5DE | 53354445 |
US146Z10 | S28C | 53323843 |
SUBJECT: PCI-X Dual Channel Ultra320 SCSI Adapter bus
******* PLEASE READ THIS ENTIRE NOTICE *********
Note: The "Adapter bus" is the integrated controller
for the Machine's Affected. This microcode does not apply to the
Ultra 320 SCSI Adapter.
2.0.1
Installation Time:
Approximately 30 minutes
2.0.2
Machine's Affected:
7029-6C3/6E3
7039-651
9114-275
3.0 Determine the Current Microcode Level:
Before you install the microcode, it is important to determine the microcode level of the Adapter bus installed in the target system. Use
the following instructions to read the ROM level stored in the Adapter bus' VPD.
1) List the SCSI initiators (adapters and controllers) installed in the system by typing:
lsdev -C | grep scsi
Note: All of the SCSI initiators addresses that are installed will bedisplayed. The SCSI initiators names will be scsiX, where X is 0, 1, etc.
2) To check the current microcode level for the adapter or controller enter the following command
lscfg -vl scsiX
Where X is the number/s of the previous command. The Command will produce output similar to
DEVICE LOCATION DESCRIPTION
scsi0 1S-08-00 PCI-X Dual Channel Ultra320 SCSI
Adapter bus
ROM Level.(alterable).......020A0018
If the ROM Level is less than XXXX0049 then you should update the microcode.4.0.0 Downloading and Unpacking the Firmware Update Package from the WEB
b) Transfer the AIX format file to the /tmp/microcode directory
(using "Save as ...").
You'll see the filename is scsi0049.bin
c) Unpack the file by executing the instructions below. You will be
asked for the password from the license agreement.
Enter the commands:
cd /tmp/microcode
chmod +x scsi0049.bin
./scsi0049.bin
[Don't overlook the periods (.) in the above command.]
The directory scsi0049 with these files will be added to
/tmp/microcode.
1) 44415255.020a0049 (Microcode Image)
Enter the following command to copy the microcode files to "
/etc/microcode " directory :
cp /tmp/microcode/scsi0049/44415255.020a0049 /etc/microcode
Enter the following commands to copy these file onto a diskette:
ls /etc/microcode/44415255.020a0049 | backup -i -v -f/dev/rfd0
This will produce AIX backup diskettes. Label the diskettes:
"PCI-X Dual Channel Ultra320 SCSI Adapter bus"
4.0.1 Downloading and Unpacking the Firmware Update Package from CORE
With the machine powered ON and AIX operational but no activity,
perform the following steps to install the FLASH code into the
SCSI Adapter bus.
1. Insert diskette with the file downloaded from CORE into the floppy diskette drive of the Media Bay.
NOTE: If the system is running LPAR, you must determine what partition has the media bay assigned.
How to determine what partition has the
diskette drive assigned when running LPAR:
A. Log onto the Hardware
Management Console (HMC).
B. On the opening
screen, in the Navigation Area, select Partition Management.
C. In the Partition
Management window, right-click on the top device listed in the
window. Select Properties.
D. Select the IOSLOT tab.
E. In the IOSLOT field,
find the SCSI initiator named PCI-X Dual Channel Ultra320 SCSI Adapter
bus.
F. Click on the + sign
next to the I/O Group associated with the PCI-X
Dual Channel Ultra320 SCSI Adapter bus. This will display the partition associated
with the diskette drive.
2. Log into the target system (or LPAR that has the media bay assigned) as root.
3. Type: restore
4.0.2 Downloading the RPM Format File
to the Target Server
Use this
method to download to an AIX system:
Note: The instructions that follow are specific AIX commands. AIX commands are CASE (lower and upper) SENSITIVE, and must be entered exactly as shown, including filenames.
a) Make a
directory on an AIX system to receive the RPM format file.
Enter: mkdir /tmp/microcode/RPM
b) Transfer the
RPM format file to the /tmp/microcode directory (using "Save as ...").
You'll see the filename is scsi.0049.rpm
c) Unpack the file by executing the instructions below:
Enter the commands:
rpm -ihv --ignoreos
scsi.0049.rpm
The microcode files will be added to /etc/microcode/
4.0.3 Downloading File from the Microcode CD-ROM
Copy microcode updates from the CD-ROM to standard locations on your local disk:
1. RPM packaged microcode files will be copied to
"/tmp/microcode/RPM"
2. Unpack the file by executing the instructions below:
Enter the commands:
rpm -ihv --ignoreos scsi.0049.rpm
3. Microcode files will be copied to "/etc/microcode".
- "/etc/microcode" is a symbolic link to "/usr/lib/microcode".
- If permission does not allow the copy to the above stated
directory
or file then the user will be prompted for a new location.
5.0 Microcode Download Procedure-PCI-X Dual Channel Ultra320 SCSI Adapter bus
NOTE: Microcode download must be performed
seperately for each Adapter bus under distinct Logical Partitions
(LPAR's).
Please save current and older versions of the microcode update files in
case you need to restore your system.
NOTE: Microcode Download CAN be performed concurrently.
Installation Time: Approximately
30 min System Time.
Please verify the file size and checksum of the raw microcode files
in /etc/microcode/. See step 10H.
Filesize: 618900
Checksum: 36795
Procedure:
1. Stop all applications.
2. Enter diag
3. Select the "Task Selection" from diagnostics menu.
4. Select "Microcode Download" from "Task Selection"
menu.
5. Select all of the PCI-X Dual Channel Ultra320 SCSI
Integrated Controllers (Adapter buses)
that needs to be updated from the list of devices by pressing "Enter".
The devices will be displayed as sisscsia#, where # is the number of
the device. Press "F7".
6. A diaglogue box will be displayed on screen. Press "Enter" to
continue.
7. Select "/etc/microcode".
8. A dialogue box will may be displayed on screen. It will state
that
the current microcode level on the adapter is not in the /etc/microcode
directory. This is acceptable as you will be flashing new
microcode
onto the adapter. Also, incorrect code will automatically be
rejected. Press "Enter" to continue.
9. An "M" will be displayed next to the latest level of microcode in
the /etc/microcode directory. Select that level and press "Enter".
10. The following message
will
appear on the screen when download is completed: "Microcode download
complete successfully. The current microcode level for the device
sisscsia# is ..... Please run diagnostics on the adapter to
ensure
that it is functioning properly." DO NOT run
diagnostics on the device at this time.
11. Exit diagnostics.
12. For systems that have LPAR installed, the microcode file must be placed on all partitions that have a SCSI device in order to update the code. Follow this procedure for each partition:
A. Log into the
target partition.
B. Type: cd
/etc/microcode
C. FTP to the partition
that has the media bay assigned. (ie. ftp partition1.ibm.com)
D. Type: cd
/etc/microcode
E. Type: bin
F. Type: get
44415255.020a0049
G. Type: quit
H. Verify the filesize
and checksum of the file by typing:
1) Filesize:
"ls -l 44415255.020a0049". The filesize should be 618900.
2) Checksum: "sum 44415255.020a0049". The checksum should be 36795.
I. Follow the above procedure to
download the microcode to all PCI-X Dual Channel Ultra320 SCSI
Integrated Controllers (Adapter
buses) in the partition.
13. Verify the code level is 0049 by typing "lscfg -vl scsi#" for each scsi device updated. <Where # is the number scsi device>