IBM pSeries Servers
Microcode Update for Ultrastar 73LZX (US73) 18/36 GB
SCSI Hard Disk Drive
Microcode Level S5DA

DATE: Dec 12,  2002
REVISED: May 8, 2003

Table of Contents

1.0 Disk Drives Affected

2.0 Microcode Change History

3.0.0 General Information
3.0.1 Installation Time

4.0 Determine Drive Model, FRU&PN and Current Microcode Level

5.0.0 Downloading and Unpacking the Firmware Update Package From WEB
5.0.1 Downloading the RPM Format File to the Target Server
5.0.2 Downloading Files from the Microcode CD-ROM

6.0.0 MicrocodeDownload Procedure-SCSI Drives Attached to SCSI Adapter - Non SP systems
6.0.1 MicrocodeDownload Procedure-SCSI Drives Attached to RAID Adapter
6.0.2 MicrocodeDownload Procedure-SP systems
===================================================================================

1.0 Disk Drives Affected:

This microcode is for use in the following SCSI hard disk drive:

                                   Assembly
Size Model             FRU#        P/N
---- --------------    ---------   --------------
18GB IC35L018UWD210    07N4813     07N6353
18GB IC35L018UCD210    07N4843     07N6383
18GB IC35L018UCD210    09P3922     07N7080
18GB IC35L018UCD210    09P3823     07N7081

36GB IC35L036UWD210    07N4803     07N6343
36GB IC35L036UCD210    07N4833     07N6373
36GB IC35L036UCD210    09P3923     07N7070
36GB IC35L036UCD210    09P3826     07N7071
 

2.0 Microcode Change History
 
Release date Code level Change Description
12/2002 S5DA Slight reduction in acoustics noise when drive is idle.
 7/2002 S5BS Initial Release

 

3.0.0 General information

SUBJECT: IBM pSeries Servers Ultrastar 73LZX  (US73) 18/36 GB Internal SCSI Hard Disk Drive
 Microcode Update Level S5DA

******* PLEASE READ THIS ENTIRE NOTICE *********
This package contains microcode files ONLY for  pSeries internal SCSI disk drives,
it does NOT include files for external disk drives(external storage boxes and drawers)

SP2 NOTE: Some of these drives are used in pSeries(RS/6000)-SP2 systems, however, the actual microcode file for SP systems are available only on internal IBM database(CORE).   You must obtain the necessary files from your local IBM Service Representative.  The SP2 procedure requires copying microcode files to the appropriate SPOT(s). Therefore, it is highly  recommended that, while the IBM Service Representative will provide the microcode, someone with an appropriate level of AIX experience and expertise performs the update, preferably the System Administrator or person(s) designated as responsible for making software updates to the system.
 

3.0.1 Installation Time: Approximately 20 minutes if drive is part of rootvg(using Diagnostics CD); Approximately 5 minutes/drive if drive is not part of rootvg(using concurrent diagnostics).
 

4.0 Determine the Drive Model, FRU&PN and Current Microcode level:
a- SCSI Drives attached to SCSI Controllers(Not RAID)
To see the drive type and current microcode level, Execute the following command:
lscfg -vl hdisk* |pg

Example of the info on a  18.2GB SCSI hard disk:
lscfg -vl hdisk2
DEVICE            LOCATION          DESCRIPTION
hdisk3            20-59-00-0,0      16 Bit LVD SCSI Disk Drive (18200 MB)
Manufacturer........................IBM
Machine Type and Model.......IC35L018UWD210-0
FRU Number........................07N4813
ROS Level and ID.................53354441
Serial Number.......................VLZEA495
EC Level...............................H32051
Part Number..........................07N6353
Device Specific.(Z0)..............000003029F00013A
Device Specific.(Z1)..............07N4908
Device Specific.(Z2)..............0068
Device Specific.(Z3)..............22238
Device Specific.(Z4)..............0001
Device Specific.(Z5)..............22
Device Specific.(Z6)..............F80470

b- SCSI Drives attached to SCSI RAID Controllers
At AIX command line, type:
Diag
Select "Task Selection" from diagnostics menu.
Select "PCI RAID Physical Disk Identify"
Select SCSI RAID Adapter (press enter, then F7 to Commit)
This will display the Vital Product Data for Physical Diak drives attached to the RAID adapter.
If "Product Type" is IC35 , and ROM/RAM Fields are below S5DA, then microcode of drive(s) need to be updated
5.0.0 Downloading and Unpacking the Firmware Update Package From WEB
NOTE: The following values apply to these microcode files:
      IC35L01.415A3030.53354441    Size: 425984    Checksum: 47904
      IC35L01.415A3031.53354441    Size: 425984    Checksum: 33765
      IC35L01.415A3032.53354441    Size: 425984    Checksum: 39890
      IC35L01.415A3033.53354441    Size: 425984    Checksum: 43806
      IC35L01.415A3034.53354441    Size: 425984    Checksum: 52351

      IC35L03.415A3030.53354441    Size: 425984    Checksum: 47904
      IC35L03.415A3031.53354441    Size: 425984    Checksum: 33765
      IC35L03.415A3032.53354441    Size: 425984    Checksum: 39890
      IC35L03.415A3033.53354441    Size: 425984    Checksum: 43806
      IC35L03.415A3034.53354441    Size: 425984    Checksum: 52351

a) Make a directory on an AIX system to receive the AIX format file.
    Enter:      mkdir /etc/microcode
b) Transfer the AIX format file to the /etc/microcode directory (using "Save as ...").
    You'll see the filename is 73lzx.bin
c) Unpack the file by executing the instructions below. You will be asked for the password from the license agreement.
  Enter the commands:
  cd /etc/microcode
  chmod +x 73lzx.bin
  ./73lzx.bin
[Don't overlook the periods (.) in the above command.]

The directory 73lzx with these files will be added to /etc/microcode.

IC35L01.415A3030.53354441
IC35L01.415A3032.53354441
IC35L01.415A3033.53354441
IC35L01.415A3034.53354441

IC35L03.415A3030.53354441
IC35L03.415A3032.53354441
IC35L03.415A3033.53354441
IC35L03.415A3034.53354441
73lzx.txt

Note: 73lzx.txt is a read me file(same as this file), it can be saved or printed for future use.

d-Enter the following command to copy the microcode files to " /etc/microcode " directory :
   cp /etc/microcode/73lzx/IC35*  /etc/microcode

e- Copy microcode file onto floppy diskette
   Note: Don't overlook the complete path of microcode files, AIX Diag microcode download will not work if files are not copied with complete path onto the diskette.  Enter the following command to copy microcode file(s) onto a floppy diskette
ls /etc/microcode/ microcodefilename  | backup -ivf /dev/rfd0
where microcodefilename is  microcode file that is needed, for example:
ls /etc/microcode/IC35L01.415A3030.53354441 | backup -ivf /dev/rfd0

The following microcode files are included in the diskettes, use the list below to find the right file for you disk drive.

                                                                Assembly
Size   Model                  FRU#              P/N             Microcode file Name
------ -------------------    -------------     -----------     ---------------------------------
18GB IC35L018UWD210    07N4813      07N6353     IC35L01.415A3030.53354441
18GB IC35L018UCD210    07N4843      07N6383     IC35L01.415A3032.53354441
18GB IC35L018UCD210    09P3922      07N7080     IC35L01.415A3033.53354441
18GB IC35L018UCD210    09P3823      07N7081     IC35L01.415A3034.53354441

36GB IC35L036UWD210    07N4803      07N6343     IC35L03.415A3030.53354441
36GB IC35L036UCD210    07N4833      07N6373     IC35L03.415A3032.53354441
36GB IC35L036UCD210    09P3923      07N7070     IC35L03.415A3033.53354441
36GB IC35L036UCD210    09P3826      07N7071     IC35L03.415A3034.53354441
 

5.0.1 Downloading the RPM Format File to the Target Server
Use this method to download to an AIX system:

Note: The instructions that follow are specific AIX commands. AIX commands are CASE (lower and upper) SENSITIVE, and must be entered exactly as shown, including filenames.

a) Make a directory on an AIX system to receive the RPM format file.
    Enter:      mkdir /etc/microcode
 
b) Transfer the RPM format file to the /etc/microcode directory (using "Save as ...").
    You'll see the filename is 73lzx-s5da.rpm

c) Unpack the file by executing the instructions below:
    Enter the commands:
        rpm -ihv --ignoreos 73lzx-s5da.rpm

The file size and checksum will be verified.

The microcode files will be added to /etc/microcode/
 

5.0.2 Downloading File from the Microcode CD-ROM

Copy microcode updates from the CD-ROM to standard locations on your local disk:

1. RPM packaged microcode files will be copied to "/tmp/microcode/RPM"
2. Microcode files will be copied to /usr/lib/microcode
Notes:
 - "/etc/microcode" is a symbolic link to "/usr/lib/microcode".
 - If permission does not allow the copy to the above stated directory
                  or file then the user will be prompted for a new location.
 

6.0.0 Microcode Download Procedure-SCSI Drives Attached to SCSI adapter - Non SP System

Warning: Do not power off the system or the drive during microcode download as this may permanently damage the disk drive

NOTE: Please save current and older versions of the microcode update files in case you need to restore your system.

Caution: The microcode download process is nondestructive to the hard disks; however, as a precaution, ensure that a backup operation has been performed on the affected systems PRIOR to the microcode installation.

Can microcode be installed Concurrently?
AIX level 5.1 and above supports concurrent microcode download on all drives, including drives that are part of rootvg.
AIX level 4.33 and below does not support concurrent microcode download if drive is part of rootvg, microcode download can ONLY be performed in service mode(stand alone) using diagnostics CD. If disk is not part of rootvg, microcode download can be performed cuncurrently as long as drive is not in use.

Is system reboot needed to activate the microcode: Yes if stand alone diagnostics is used, NO if concurrent diagnostics is used.

Installation Time: Approximately 20 minutes/drive if stand alone diagnostics is used(using Diagnostics CD); Approximately 5 minutes/drive if consurrent diagnostics is used.

Procedure(AIX level 4.33 and below):
a- Online(Concurrent) Diagnostics(for drives that are not part of rootvg or paging space):
1. This step is optional.  Microcode download can be performed either from Diskette or from Disk.To copy files from the diskette to disk, place the diskette containing microcode files into diskette drive A, at AIX Prompt type   restore
2- At AIX prompt, type   diag
3. Select the "Task Selection" from diagnostics menu.
4. Select "Microcode Download" from "Task Selection" menu.
5. Select resource that microcode will be applied to(hdisk?) and press ENTER.
6. Press "F7" to commit.
      (The current microcode level of the resource you selected earlier will be displayed at the top of the screen)
7. Make the following selections on the next screen:
    Select Input Device --------------------------------------- [ diskette]  <---------- Disk can be used if  "restore" command is used in step 1
    Microcode level to download ----------------------------- [ latest]
    Download latest level even if ------------------------------ [ yes]
    current is missing
NOTE: A prompt will ask you to insert the microcode diskette into the floppy drive(if Diskette is selected above).  Insert the diskette which accompanies these instructions. If this level is already installed in the drive you've selected a message will let you know. A message also may come up to let you know that the Diskette(or Disk) does not have the previous level microcode file. This is true and is not required to complete the download.
PRESS "F7" to commit
8. You will receive a msg. "Current Microcode is....and...Download has completed successfully"
       (this may take a few minutes)
9. Return to the Tasks Selection menu and repeat this procedure for each hard disk that requires this microcode.
10. Exit diagnostic.

b- Standalone Diagnostics (for all drives including rootvg or paging space drives):
1. Properly shutdown the system.
2. Boot up the system in standalone diagnostics mode with the CDROM diagnostics(Use diagnostics level 4.21 or above;  It is recommended to use the same level
    of  Diagnostic CD as the AIX ).
3. Select the "Task Selection" from diagnostics menu.
4. Select "Microcode Download" from "Task Selection" menu.
5. Select resource that microcode will be applied to(hdisk?) and PRESS ENTER.
6. Press "F7" to commit.
      (The current microcode level of the resource you selected earlier will be displayed at the top of the screen)
7. Make the following selections on the next screen:
    Select Input Device --------------------------------------- [ diskette]
    Microcode level to download -----------------------------[ latest]
    Download latest level even if -----------------------------[ yes]
    current is missing

NOTE: A prompt will ask you to insert the microcode diskette into the floppy drive.  Insert the diskette which accompanies these instructions. If this level is already installed in the drive you've selected a message will let you know. A message also may come up to let you know that the Diskette(or Disk) does not have the previous level microcode file. This is true and is not required to complete the download.
PRESS "F7" to commit
8. You will receive a msg. "Current Microcode is...." and "Download has completed successfully"
       (this may take a few minutes)
9. Return to the Tasks Selection menu and repeat this procedure for each hard disk that requires this microcode.
10. Exit diagnostic and reboot system in normal mode.

Procedure (AIX level 5.1 and above):
1. Type diag at the prompt.
2. Select the "Task Selection" from diagnostics menu.
3. Select "Microcode Download" from "Task Selection" menu.
4. Select resource that microcode will be applied to(hdisk?) and press ENTER, then press "F7" to commit..
5- A small screen displays the message " *** NOTICE***  The microcode installation occurs while the attached drives are avilable for use..... "
    Press enter to continue
6.  Select the source for microcode, use arrow key to go up/down, Enter to continue.
                      /etc/microcode
                      diskette

   - Use /etc/microcode if "restore" command is used to copy files from diskette onto the disk
   - Use diskette if using diskette as the source for download

NOTE: A prompt will ask you to insert the microcode diskette in diskette drive(if Diskette is selected above).  Insert the diskette and press ENTER

7- Display shows a list of microcodes avilable for the selected drive, highlight option "M  IC35xx...", the latest microcode for the drive listed below and press ENTER. A message may warn you that current level of microcode is not available on the media, press ENTER to continue.

8. You will receive a msg. "Current Microcode is...." and "Download has completed successfully"
       (this may take a few minutes)
9. Return to the Tasks Selection menu and repeat this procedure for each hard disk that requires this microcode.
10. Exit diagnostic(and reboot if needed).
 

6.0.1 Microcode Download Procedure-SCSI Drives Attached to RAID Adapter

NOTE: Please save current and older versions of the microcode update files in case you need to restore your system.

Procedure:
1. At AIX Command line type:
    diag
2. Select the "Task Selection" from diagnostics menu.
3. Select "Microcode Download" from "Task Selection" menu.
4. Select RAID controller from the list of resources, PRESS ENTER, then F7 to commit
5. Select "Physical Disks" and PRESS ENTER
6. A list of all Physical Disks will be displayed, select the disk that needs to be upgraded, PRESS ENTER and F7 to commit.
7. Select "Latest level"
8. Select "Disk" if files are copied to /etc/microcode directory. Select "Diskette" if microcode files are saved onto a diskette, PRESS ENTER
    (The current microcode level of the resource you selected earlier will be displayed at the top of the screen)

9.  You will receive a message "Download has completed successfully" and "Current Microcode is"   (this may take a few minutes).
10. Return to the Previous menu and repeat this procedure for each hard disk that requires this microcode.
11. Exit diagnostic and reboot system.
 

6.0.2 SCSI Disk Drive Microcode Download Procedure-SP systems
This procedure requires copying microcode files to the appropriate SPOT(s). Therefore, it is HIGHLY recommended that someone with an appropriate level of AIX experience and expertise should perform this task, preferably the System Administrator of person(s) designated as responsible for making software updates to the system.

Warning: Do not power off the system or the drive during microcode download as this may permanently damage the disk drive

NOTE: Please save current and older versions of the microcode update files in case you need to restore your system.

Caution: The microcode download process is nondestructive to the hard disks; however, as a precaution, ensure that a backup operation has been performed on the affected systems PRIOR to the microcode installation.

Can microcode be installed Concurrently?
 NO. If the disk is part of rootvg or used as a paging device, microcode download can ONLY be performed while node is "Network Booted" into "Diagnostic Standalone Mode".

Is system reboot needed to activate the microcode: Yes

Installation Time: Installation time will vary depending upon the system configuration

Procedure for SP System (Nodes):

Note: Make sure that node on which work is to be performed has been "fenced" from the switch.
1. Obtain proper microcode diskette from from your IBM Service Representative.
2. Copy microcode file from diskette onto CWS:
     restore -xvq
     (file will be copied into the "etc/microcode" directory)

3. Move microcode file from "etc/microcode" directory to the appropriate Spot(s) that are used by the customer for the node(s) to be updated.
    ie: /spdata/sys1/install/aix4??/spot/spot_aix4??/usr/lib/microcode                (??= level of AIX on your system)

4. To set the Node(s) to boot from network, from CWS, run command:
    spbootins -r diag [frame#] [node#] [node count]
    (example - - spbootins -r diag 1 13 1)

5. From Perspectives, perform a "Shutdown" for the node(s) to be updated.
6. From perspectives screen for node to be updated, select "Network Boot" and wait for TTY to open to DIAG MENU.
7. Choose "Task Selection".
8. Choose your terminal type.
9. Select "Download Microcode"
10. Select resource that microcode will be applied to(hdisk?) and PRESS ENTER.
11. Press "F7" to commit.
      (The current microcode level of the resource you selected earlier will be displayed at the top of the screen)
12.  In the "Select the input device" screen, make sure settings are as follows:

      Select Input Device --------------------------------------- [ disk]
      Microcode level to download ----------------------------- [ latest]
      Download latest level even if ------------------------------ [ yes]
      current is missing

PRESS "F7" to commit

13. You will receive a msg. "Current Microcode is" and "Download has completed successfully"
       (this may take a few minutes)

14. On CWS run the following command:
      spbootins -r disk [frame# [node#] [node count]

15. On CWS, After spbootins finishes, run the following command:
      splstdata -b (check output to see that node in question was set back to disk)

16. On "TTY" screen for node, Press F10 to get to "Shutdown Screen" and close TTY screen.
17. On perspectives screen of affected node, do a power off of the node and a power on of the node.
18. After node boots, telnet to the node, run the following command and check that correct microcode level has been updated.
          lscfg -vl hdisk# (ie hdisk0,hdisk1 etc).


Privacy | Legal | Contact IBM