IBM pSeries Microcode Update for Cheetah 146LP Model ST3xxxx7LW/LC
18.2/36.4/73.4/146 GB
SCSI Hard Disk Drive. Microcode Level C50K(ROS Level 4335304B)

DATE: December 9, 2005




Table of Contents

1.   General Information

1.1 Disk Drives Affected

1.2 Microcode Change History

2.  AIX Operating System

2.1 Installation Time

2.2 Determine Drive Model, FRU&PN and Current Microcode Level

2.2.2  SCSI Drives attached to PCI SCSI RAID Controllers

2.3 Transferring and Unpacking the Microcode Update Package

2.3.1 Internet AIX self extracting file (.bin)

2.3.2 Internet RPM package

2.3.3 CD-ROM

2.4 Microcode Download Procedure

2.4.1 SCSI Drives Attached to SCSI Adapter

2.4.2 SCSI Drives Attached to PCI RAID Adapter

2.4.3 SP systems

3.   Linux Operating System

3.1  Linux 2.6 kernel(such as SuSE SLES 9 or RHEL 4)

3.2 RHEL 3

3.3 SLES 8 SP4

===============================================================

1.   General Information

The Microcode files provided in this package are only for use when installing disk drive microcode to a disk drive installed in an IBM pSeries/RS6000 system using the AIX or Linux Operating System.

 

1.1 Disk Drives Affected 

Below is the list of microcode files in this package, these files are for use with the following pSeries SCSI disk drives ONLY:

NOTE: To insure the integrity of microcode files, please make sure the checksum value is correct after extraction

 

Size          Model       FRU #    P/N     Microcode File Name           Checksum
------------ ----------  -------  ------- -------------------------  ----------
pSeries Internal Drives
18G (68 pin) ST318307LW  00P3061  00P2683 ST31830.53313030.4335304B   14003
18G (80 pin) ST318307LC  00P3063  00P2681 ST31830.53313032.4335304B   14003
18G (80 pin) ST318307LC  00P3064  00P2680 ST31830.53313033.4335304B   14003
18G (80 pin) ST318307LC  09P4437  00P2682 ST31830.53313034.4335304B   14003
36G (68 pin) ST336607LW  00P3065  00P2679 ST33660.53313130.4335304B   14003
36G (80 pin) ST336607LC  00P3067  00P2677 ST33660.53313132.4335304B   14003
36G (80 pin) ST336607LC  00P3068  00P2676 ST33660.53313133.4335304B   14003
36G (80 pin) ST336607LC  09P4447  00P2678 ST33660.53313134.4335304B   14003
73G (68 pin) ST373307LW  00P3069  00P2675 ST37330.53313230.4335304B   31859
73G (80 pin) ST373307LC  00P3071  00P2673 ST37330.53313232.4335304B   31859
73G (80 pin) ST373307LC  00P3072  00P2672 ST37330.53313233.4335304B   31859
73G (80 pin) ST373307LC  09P4890  00P2674 ST37330.53313234.4335304B   31859
146G(80 pin) ST314687LC  00P2665  00P2664 ST31468.53313333.4335304B   49411
146G(80 pin) ST314687LC  00P2669  00P2668 ST31468.53313334.4335304B   49411

2104 Drives:
18G (80 pin) ST318307LC  55P4068  55P4066 ST31830.44543032.4335304B   14003
18G (80 pin) ST318307LC  55P4070  55P4066 ST31830.44543132.4335304B   14003
36G (80 pin) ST336607LC  55P4073  55P4071 ST33660.44543033.4335304B   14003
36G (80 pin) ST336607LC  55P4075  55P4071 ST33660.44543133.4335304B   14003
73G (80 pin) ST373307LC  55P4078  55P4076 ST37330.44543034.4335304B   31859
73G (80 pin) ST373307LC  55P4080  55P4076 ST37330.44543134.4335304B   31859
146G(80 pin) ST314687LC  55P4083  55P4081 ST31468.44543035.4335304B   49411
146G(80 pin) ST314687LC  55P4085  55P4081 ST31468.44543135.4335304B   49411

 

 

1.2 Microcode Change History

  Release date

MC Level

Change Description

12/09/2005

C50K

-Changed drive behavior when it fails DWD (Dropped Write Detect) self test, drive will not go into  read/write protect when self test fails  because  of time-out,  other fixes and enhancement

9/2/2004

C50J

-Added DWD (Dropped Write Detect) function for reliability enhancement (this change is transparent to users), drive becomes “Write Protect” when DWD offline test fails.

-Disabled Format Certification (Raid manager Format time is the same as AIX Diag format now)

2/2/2004

C50H

This level of code enables a feature that clears busy condition in rare situations that drive reports busy status.

10/21/2003

C50F

Fixes and enhancement for drive to work with the new "PCI-X Ultra 320 Dual Channel SCSI Adapter" and "PCI-X Dual Channel SCSI RAID Adapter". This level of code supports 522 Bytes/sector format, and it is the minimum requirement for this drive to function properly with new adapters.

12/23/2002

C50C

Initial Released version 

 

===============================================================

2.  AIX Operating System

2.1 Installation Time

Approximately 20 minutes if drive is part of rootvg(using Diagnostics CD); Approximately 5 minutes/drive if drive is not part of rootvg(using concurrent diagnostics).
 

2.2 Determine Drive Model, FRU&PN and Current Microcode Level
2.2.1  SCSI Drives attached to SCSI Controllers  and PCI-X RAID Adapters

To see the drive type and current microcode level, Execute the following command:
lscfg -vl hdisk* |pg      ; For drives NOT configured for RAID

lscfgvl pdisk* |pg     ; For drives configured for RAID

 

Example of the info on a  18.2GB SCSI hard disk:
lscfg -vl hdisk1

DEVICE            LOCATION          DESCRIPTION

  hdisk1            10-68-00-13,0     16 Bit LVD SCSI Disk Drive (18200MB)

        Manufacturer................IBM
        Machine Type and Model......ST318307LW
        FRU Number..................00P3061
        ROS Level and ID............4335304B
        Serial Number...............3JK0031Q
        EC Level....................0H11333
        Part Number.................00P2683
        Device Specific.(Z0)........000003129F00013E
        Device Specific.(Z1)........1109C513
        Device Specific.(Z2)........1000
        Device Specific.(Z3)........01309
        Device Specific.(Z4)........0001
        Device Specific.(Z5)........22
        Device Specific.(Z6)........162870 C

 

If the data returned in the “Part Number”, “FRU Number”, and “Machine Type and Model  fields match the one listed in section 1.1 AND the "ROS Level and ID...." field of that data is below "4335304B", this microcode applies. If this level is already installed then the "ROS Level and ID...."  shows:  "4335304B "
Note: Drive microcode level in “ROS Level and ID …” field is displayed in Hex value of ASCII characters in VPD data. Each alpha-numeric ASCII character converts to a 2-digit hex number. For example in VPD displayed above, 43 Hex= ASCII character "C";  35 Hex= ASCII character "5"; 30 Hex=ASCII character "0"; 4B Hex=ASCII character "K",  microcode level is "C50K".

For SP systems with multiple nodes, you can use the following command to query all of the nodes at one time. Use of this command will also limit the amount of data returned, making it easier to audit.  It returns only the pertinent information: node name, hdisk number, ROS Level and ID and part number.

dsh -a lscfg -v |egrep 'hdisk|ROS|Part'

pesp_n1:   hdisk0            10-60-00-0,0      16 Bit LVD SCSI Disk Drive (18200MB)
pesp_n1:         ROS Level and ID............4335304B
pesp_n1:         Part Number.................00P2683
pesp_n5:   hdisk0            10-60-00-0,0      16 Bit LVD SCSI Disk Drive (18200MB)
pesp_n5:         ROS Level and ID............4335304B
pesp_n5:         Part Number.................00P2683
pesp_n5:   hdisk1            10-60-00-8,0      16 Bit LVD SCSI Disk Drive (18200MB)
pesp_n5:         ROS Level and ID............4335304B
pesp_n5:         Part Number.................00P2683

2.2.2  SCSI Drives attached to PCI SCSI RAID Controllers

At AIX command line, type:
Diag
Select "Task Selection" from diagnostics menu.
Select "PCI RAID Physical Disk Identify"
Select SCSI RAID Adapter (press enter, then F7 to Commit)
This will display the Vital Product Data for Physical Disk drives attached to the RAID adapter.

===============================================================

2.3 Transferring and Unpacking the Microcode Update Package

2.3.1 Internet AIX self extracting file (.bin)

a) Make a directory on an AIX system to receive the AIX format file.
    Enter:      mkdir /tmp/fwupdate
b) Transfer the AIX format file to /tmp/fwupdate directory (using "Save as ...").
    You'll see the filename is 146lp.bin
c) Unpack the file by executing the instructions below.
  Enter the commands:
  cd /tmp/fwupdate
  chmod +x 146lp.bin
  ./146lp.bin
[Don't overlook the periods (.) in the above command.]

The directory 146lp with microcode files listed in section 1.1 will be added to /tmp/fwupdate.
 

d-Enter the following command to copy the microcode files to " /etc/microcode " directory :
   cp /tmp/fwupdate/146lp/ST3*  /etc/microcode

e- If transferring files to a different system using floppy diskettes, use the following procedure to copy files to diskette
   Note: Don't overlook the complete path of microcode files, AIX Diag microcode download will not work if files are not copied with complete path onto the diskette.  Enter the following command to copy microcode file(s) onto a floppy diskette
ls /etc/microcode/ microcodefilename  | backup -ivf /dev/rfd0
where microcodefilename is  microcode file that is needed, for example:
ls /etc/microcode/ ST31830.53313030.4335304B | backup -ivf /dev/rfd0

2.3.2 Internet RPM package

Note: The instructions that follow are specific AIX commands. AIX commands are CASE (lower and upper) SENSITIVE, and must be entered exactly as shown, including filenames.

a) Make a directory on an AIX system to receive the RPM format file.
    Enter:      mkdir /tmp/microcode

b) Transfer the RPM format file to the /tmp/microcode directory (using "Save as ...").
    You'll see the filename is 146lp-C50K-AIX.rpm

c) Unpack the file by executing the instructions below:
    Enter the commands:
        rpm -ihvignoreos  146lp-C50K -AIX.rpm

The file size and checksum will be verified.

The microcode files will be added to /etc/microcode/
 

2.3.3 CD-ROM

Copy microcode updates from the CD-ROM to standard locations on your local disk:

1. RPM packaged microcode files will be copied to "/tmp/microcode/RPM"
2. Microcode files will be copied to /usr/lib/microcode

Notes:
 - "/etc/microcode"  is a symbolic link to   "/usr/lib/microcode".
 - If permission does not allow the copy to the above stated directory
   or file then the user will be prompted for a new location.
========================================================

2.4 Microcode Download Procedure

2.4.1 SCSI Drives Attached to SCSI Adapter

Warning: Do not power off the system or the drive during microcode download as this may permanently damage the disk drive

NOTE: Please save current and older versions of the microcode update files in case you need to restore your system.

Caution: The microcode download process is nondestructive to the hard disks; however, as a precaution, ensure that a backup operation has been performed on the affected systems PRIOR to the microcode installation.

Can microcode be installed Concurrently?
AIX level 5.1 and above supports concurrent microcode download on all drives, including drives that are part of rootvg.
AIX level 4.33 and below does not support concurrent microcode download if drive is part of rootvg, microcode download can ONLY be performed in service mode(stand alone) using diagnostics CD. If disk is not part of rootvg, microcode download can be performed cuncurrently as long as drive is not in use.

Is system reboot needed to activate the microcode: Yes if stand alone diagnostics is used, NO if concurrent diagnostics is used.

Installation Time: Approximately 20 minutes/drive if stand alone diagnostics is used(using Diagnostics CD); Approximately 5 minutes/drive if consurrent diagnostics is used.

2.4.1.1 AIX level 5.1 and above

2.4.1.2.1 Concurrent Download

1. Type diag at the prompt.
2. Select the "Task Selection" from diagnostics menu.
3. Select "Microcode Download" from "Task Selection" menu.
4. Select resource that microcode will be applied to(hdisk? For physical disk, pdisk for RAID configured disks) and press ENTER, then press "F7" to commit..
5- A small screen displays the message " *** NOTICE***  The microcode installation occurs while the attached drives are available for use..... "
    Press enter to continue
6.  Select the source for microcode, use arrow key to go up/down, Enter to continue.
                      /etc/microcode
                      diskette

   - Use /etc/microcode if "restore" command is used to copy files from diskette onto the disk
   - Use diskette if using diskette as the source for download

NOTE: A prompt will ask you to insert the microcode diskette in diskette drive(if Diskette is selected above).  Insert the diskette and press ENTER

7- Display shows a list of microcodes available for the selected drive, highlight option "M  ST3xx...", the latest microcode for the drive and press ENTER. A message may warn you that current level of microcode is not available on the media, press ENTER to continue.

8. You will receive a msg. "Current Microcode is...." and "Download has completed successfully"
       (this may take a few minutes)
9. Return to the Tasks Selection menu and repeat this procedure for each hard disk that requires this microcode.
10. Exit diagnostic(and reboot if needed).
 

2.4.1.2 AIX level 4.33:
 This procedure is for drives that are not part of rootvg or paging space:
1. This step is optional.  Microcode download can be performed either from Diskette or from Disk. To copy files from the diskette to disk, place the diskette containing microcode files into diskette drive A, at AIX Prompt type   restore
2- At AIX prompt, type   diag
3. Select the "Task Selection" from diagnostics menu.
4. Select "Microcode Download" from "Task Selection" menu.
5. Select resource that microcode will be applied to(hdisk?) and press ENTER.
6. Press "F7" to commit.
     (The current microcode level of the resource you selected earlier will be displayed at the top of the screen)
7. Make the following selections on the next screen:
    Select Input Device --------------------------------------- [ diskette]  <---------- Disk can be used if  "restore" command is used in step 1
    Microcode level to download ----------------------------- [ latest]
    Download latest level even if ------------------------------ [ yes]
    current is missing
NOTE: A prompt will ask you to insert the microcode diskette into the floppy drive(if Diskette is selected above).  Insert the diskette which accompanies these instructions. If this level is already installed in the drive you've selected a message will let you know. A message also may come up to let you know that the Diskette(or Disk) does not have the previous level microcode file. This is true and is not required to complete the download.
PRESS "F7" to commit
8. You will receive a msg. "Current Microcode is....and...Download has completed successfully"
       (this may take a few minutes)
9. Return to the Tasks Selection menu and repeat this procedure for each hard disk that requires this microcode.
10. Exit diagnostic.

 

2.4.1.2.2 Standalone (Service Mode) Download

This procedure is used for all drives including rootvg or paging space drives
1. Properly shutdown the system.
2. Boot up the system in standalone diagnostics mode with the CDROM diagnostics(Use diagnostics level 4.21 or above;  It is recommended to use the same level
    of  Diagnostic CD as the AIX ).
3. Select the "Task Selection" from diagnostics menu.
4. Select "Microcode Download" from "Task Selection" menu.
5. Select resource that microcode will be applied to(hdisk?) and PRESS ENTER.
6. Press "F7" to commit.
      (The current microcode level of the resource you selected earlier will be displayed at the top of the screen)
7. Make the following selections on the next screen:
    Select Input Device --------------------------------------- [ diskette]
    Microcode level to download -----------------------------[ latest]
    Download latest level even if -----------------------------[ yes]
    current is missing

NOTE: A prompt will ask you to insert the microcode diskette into the floppy drive.  Insert the diskette which accompanies these instructions. If this level is already installed in the drive you've selected a message will let you know. A message also may come up to let you know that the Diskette(or Disk) does not have the previous level microcode file. This is true and is not required to complete the download.
PRESS "F7" to commit
8. You will receive a msg. "Current Microcode is...." and "Download has completed successfully"
       (this may take a few minutes)
9. Return to the Tasks Selection menu and repeat this procedure for each hard disk that requires this microcode.
10. Exit diagnostic and reboot system in normal mode.

                             

2.4.2 SCSI Drives Attached to PCI RAID Adapter

NOTE: Please save current and older versions of the microcode update files in case you need to restore your system.

1. At AIX Command line type:
    diag
2. Select the "Task Selection" from diagnostics menu.
3. Select "Microcode Download" from "Task Selection" menu.
4. Select RAID controller from the list of resources, PRESS ENTER, then F7 to commit
5. Select "Physical Disks" and PRESS ENTER
6. A list of all Physical Disks will be displayed, select the disk that needs to be upgraded, PRESS ENTER and F7 to commit.
7. Select "Latest level"
8. Select "Disk" if files are copied to /etc/microcode directory. Select "Diskette" if microcode files are saved onto a diskette, PRESS ENTER
    (The current microcode level of the resource you selected earlier will be displayed at the top of the screen)

9.  You will receive a message "Download has completed successfully" and "Current Microcode is"   (this may take a few minutes).
10. Return to the Previous menu and repeat this procedure for each hard disk that requires this microcode.
11. Exit diagnostic and reboot system.

2.4.3 SP systems
This procedure requires copying microcode files to the appropriate SPOT(s). Therefore, it is HIGHLY recommended that someone with an appropriate level of AIX experience and expertise should perform this task, preferably the System Administrator of person(s) designated as responsible for making software updates to the system.

Warning: Do not power off the system or the drive during microcode download as this may permanently damage the disk drive

NOTE: Please save current and older versions of the microcode update files in case you need to restore your system.

Caution: The microcode download process is nondestructive to the hard disks; however, as a precaution, ensure that a backup operation has been performed on the affected systems PRIOR to the microcode installation.

Can microcode be installed Concurrently?
 NO. If the disk is part of rootvg or used as a paging device, microcode download can ONLY be performed while node is "Network Booted" into "Diagnostic Standalone Mode".

Is system reboot needed to activate the microcode: Yes

Installation Time: Installation time will vary depending upon the system configuration

Procedure for SP System (Nodes):

Note: Make sure that node on which work is to be performed has been "fenced" from the switch.
1. Obtain proper microcode diskette from your IBM Service Representative.
2. Copy microcode file from diskette onto CWS:
     restore -xvq
     (file will be copied into the "etc/microcode" directory)

3. Move microcode file from "etc/microcode" directory to the appropriate Spot(s) that are used by the customer for the node(s) to be updated.
    ie: /spdata/sys1/install/aix4??/spot/spot_aix4??/usr/lib/microcode                (??= level of AIX on your system)

4. To set the Node(s) to boot from network, from CWS, run command:
    spbootins -r diag [frame#] [node#] [node count]
    (example - - spbootins -r diag 1 13 1)

5. From Perspectives, perform a "Shutdown" for the node(s) to be updated.
6. From perspectives screen for node to be updated, select "Network Boot" and wait for TTY to open to DIAG MENU.
7. Choose "Task Selection".
8. Choose your terminal type.
9. Select "Download Microcode"
10. Select resource that microcode will be applied to(hdisk?) and PRESS ENTER.
11. Press "F7" to commit.
      (The current microcode level of the resource you selected earlier will be displayed at the top of the screen)
12.  In the "Select the input device" screen, make sure settings are as follows:

      Select Input Device --------------------------------------- [ disk]
      Microcode level to download ----------------------------- [ latest]
      Download latest level even if ------------------------------ [ yes]
      current is missing

PRESS "F7" to commit

13. You will receive a msg. "Current Microcode is" and "Download has completed successfully"
       (this may take a few minutes)

14. On CWS run the following command:
      spbootins -r disk [frame# [node#] [node count]

15. On CWS, After spbootins finishes, run the following command:
      splstdata -b (check output to see that node in question was set back to disk)

16. On "TTY" screen for node, Press F10 to get to "Shutdown Screen" and close TTY screen.
17. On perspectives screen of affected node, do a power off of the node and a power on of the node.
18. After node boots, telnet to the node, run the following command and check that correct microcode level has been updated.
          lscfg -vl hdisk# (ie hdisk0,hdisk1 etc).

======================================================

3.   Linux Operating System

3.1  Linux 2.6 kernel(such as SuSE SLES 9 or RHEL 4)

 

Microcode can be updated using the iprconfig utility. The iprconfig utility

allows for multiple levels of adapter and device microcode to exist on the

system at the same time. After the device to update microcode is

selected, all available microcode levels are presented to choose to download.

 

1.

     a) If using SLES 9 base, install the package by typing:

         rpm -ivh --ignoreos 146lp-C50K -AIX.rpm

     b) If using SLES 9 SP1 or better or RHEL 4 or better, install the package by typing:

                        rpm -ivh 146lp-C50K -LINUX.rpm

2. Update the microcode by typing:

                         iprconfig

    Press Enter.

3. Select Download microcode and press Enter.

4. Select the device you wish to update by typing a 1 then pressing Enter. Multiple devices may be selected.

5. Select the microcode image to be downloaded to the device by typing a 1 then pressing Enter.

6. Press Enter again to confirm the download (display shows “Microcode Download in Progress” with elapsed time)

7. If multiple devices were selected, repeat from Step 5 for the next device.

 

To check the microcode level:

 

1. Start iprconfig utility,

2. Select "Display hardware status" option.

3. Select disk to query by typing a 1 next to it and pressing "Enter"

4. Look at the "Firmware Version" field

 

 

--------------------------------------------------------------------------

3.2 RHEL 3:

 

Microcode can be updated using the iprupdate utility. If iprupdate finds newer

microcode on the system it will be downloaded to the disk.

 

1. Install the package by typing:

                         rpm -ivh --ignoreos 146lp-C50K-AIX.rpm

    Press Enter.

2. Update the microcode by typing:

                         iprupdate

    Press Enter.

 

To check the microcode level:

 

1. Start iprconfig utility,

2. Select "Display disk hardware status" option.

3. Find the disk you wish to query and note its serial number.

4. Type "d" to get to the "Display disk unit details" screen.

5. Select disk to query by typing a 5 next to it and pressing "Enter"

6. Look at the "Firmware Version" field

 

-------------------------------------------------------------------------

3.3 SLES 8 SP4

 

Microcode can be updated using the sisupdate utility. If sisupdate finds newer

microcode on the system it will be downloaded to the disk.

 

1. Install the package by typing:

                         rpm -ivh --ignoreos 146lp-C50K-AIX.rpm

    Press Enter.

2. Update the microcode by typing:

                         sisupdate

    Press Enter.

 

To check the microcode level:

 

1. Start sisconfig utility,

2. Select "Display disk hardware status" option.

3. Find the disk you wish to query and note its serial number.

4. Type "d" to get to the "Display disk unit details" screen.

5. Select disk to query by typing a 5 next to it and pressing "Enter"

6. Look at the "Firmware Version" field