IBM Power Subsystem Firmware Update
for use with
System Firmware Release 230 Level 145 ONLY:
pSeries 9119-590
pSeries 9119-595
iSeries 9406-590
pSeries 9118-575
DATE: October 14, 2005
Table of Contents
1.0 Firmware Change History
2.0 General Information
2.0.0 Where to Obtain the Firmware
2.0.1 How to Load the Firmware
2.1 Cautions and Important Notes
Code Level |
Creation Date |
Description |
BP230_145 |
August 12, 2005 |
GA5 Service Pack 3:
- Increased the error log maximum size to prevent data from being truncated
|
BP230_143 |
July 29, 2005 |
GA5 Service Pack 2:
- Fix for false 11008720 & 1100821 errors during run time
- Fix for intermittent unowned I/O drawer condition after frame initialization
- Fix for false 14001302 error during boot up
- Fix for problem causing error message "no redundant hardware available"
- Fix for BPC dump during Power code load operation, causing HMC to display error ACT01724
- Fix for BPC hanging with return code 7 sent to HMC. Power code load operation fails
|
BP230_131 |
June 6, 2005 |
GA5 Service Pack 1
|
BP230_125 |
May 23, 2005 |
pSeries High Performance Switch General Availability (GA5)
|
BP225_094 |
February 17, 2005 |
pSeries 9118-575 General Availability (GA4)
|
BP222_072 |
December 16, 2004 |
GA3 Service Pack 2
|
BP222_067 |
December 06, 2004 |
GA3 Service Pack 1
|
BP222_058 |
November 21, 2004 |
pSeries 9119-590, 9119-595 and iSeries 9406-590 General Availability (GA3)
|
The Power Subsystem Firmware level contained in this update is:
BP230_145
The individual internal Power FRU code levels are:
Internal FRU Name | Code Level |
(hex) | (decimal) |
BPC 196 | 000A | 10 |
BPC DSP | A387 | 41863 |
BPR | A01A | 40986 |
CEC MDA-S | 039B | 923 |
CEC DCA-SQ | E509 | 58633 |
Node DCA-SIH | 0008 | 8 |
I/O DCA-BC | 003B | 59 |
I/O MDA-BC | 0005 | 5 |
I/O DCA-BCS | 0036 | 54 |
I/O MDA-BCS | 0406 | 1030 |
HPS DCA-F | 003A | 58 |
HPS MDA-F | 0394 | 916 |
This package provides updated Power Subsystem Firmware for use on the following systems only:
- pSeries 9119-590
- pSeries 9119-595
- pSeries 9118-575
- pSeries Powered Expansion Rack
- pSeries High Performance Switch in any of the above Systems
- pSeries High Performance Switch Multi-rack Configuration
- iSeries 9406-590
Do not use on any other systems. The package contains downloadable
Firmware for some or all of the following power subsystem components: BPC
(Bulk Power Controller), BPR (Bulk Power Regulator), DCA (Distributed Converter
Assembly and MDA (Motor Drive Assembly).
This firmware can be found at the following locations:
IMPORTANT NOTE:
Before attempting to load this firmware please ensure that your HMC software
has been upgraded to Version 4, Release 5.0 (or newer) and that the
Required V4R5.0 Maintenance eFix (MH00318) package has been applied.
HMC software packages can be found at:
http://techsupport.services.ibm.com/server/hmc/power5/fixes/v4r5.html
The instructions regarding how to query, obtain, install and remove firmware
levels can be found by following these steps:
- Go to the Infocenter Home Page:
http://publib.boulder.ibm.com/infocenter/eserver/v1r2s/en_US/index.htm
- In the left had column click on: Service and support
- Click on: Customer service and support
- Click on: Getting fixes
- Click on: Firmware (Licensed Internal Code) fixes
- Click on: Managing firmware (Licensed Internal Code) fixes
At this point you will find information on the following topics:
- Viewing existing firmware (Licensed Internal Code) levels
- Viewing available firmware (Licensed Internal Code) levels
- Viewing the fix cover letter
- Removing the current firmware (Licensed Internal Code) level
- Getting a server firmware fix on optical media
- Getting a specific firmware (Licensed Internal Code) fix
- Installing a firmware (Licensed Internal Code) fix permanently
- Upgrading to a new firmware (Licensed Internal Code) release
- Never Turn Off the UEPO switch (red switch) During the Power Subsystem
Firmware Update Process --
the update will fail, and the process must be repeated. Also,
the power component being loaded could be permanently disabled.
- Never Log Off of the HMC During the Power Subsystem Firmware Update
Process --
the update will fail, and the process must be repeated.
- Service any existing problems with the Power Subsystem prior to
attempting to load Power Subsystem Firmware from the HMC. Outstanding
problems can cause the Power Subsystem to be in an N-mode power state
(which means there has been a loss of redundancy) and can prevent the HMC
from being able to load the Power Subsystem Firmware.
IMPORTANT NOTE:
After installing the Power Subsystem Firmware, proceed to the HMC console and rebuild the
managed frame using the following procedure:
- From the "Navigation Area" window pane on the HMC Console:
- select Server and Partition
- select Frame Management
- Next, from the "Server and Partition: Frame Management" window pane:
- right-click on the frame that was just updated
- select Rebuild Managed Frame
- answer Yes to the question "Do you want to continue?"