Power5 Firmware
Applies to: OpenPower, i5 and p5 Servers and IntelliStation
285
This document provides information about the installation of Licensed
Machine or Licensed Internal Code, which is sometimes referred to generically
as microcode or firmware.
Contents
1.0 Systems Affected
This package provides new firmware for OpenPower, i5 and p5 Servers and
IntelliStation 285.
The firmware level in this package is:
2.0 Cautions and Important Notes
Do not attempt to backlevel firmware from any given
release level to an earlier release level unless directed to do so by IBM.
If you feel that it is necessary to backlevel the firmware on your system
to an earlier release level and you have not been directed to do so by
IBM, please contact your next level of support.
The following page will display the recommended HMC code and server
firmware levels for the currently supported Power5 releases. Power5
Code Matrix: http://www14.software.ibm.com/webapp/set2/sas/f/hmc/power5/tips/matrix.html.
Memory Considerations for Firmware Upgrades
Customers may encounter changes in the amount of memory the firmware requires
when upgrading to a new release level. These memory usages inscreases
are to accommodate the increase in firmware functiononality the new release
provides.
HMC-MANAGED SYSTEMS
-
You must upgrade your HMC code to Version 5, Release 1.0 or later before
attempting to load this system firmware on your server.
-
HMC corrective service is available for use with this service pack.
It is strongly recommended that HMC required maintenance MH00507 or later
be installed.
-
You must logged in as hscroot in order for the firmware installation to
complete correctly.
Go to the following URL to access the HMC code packages http://www14.software.ibm.com/webapp/set2/sas/f/hmc/power5/download/v51.Update.html.
Attention: Before installing firmware on an HMC
managed system:
-
If installing this level of firmware as a disruptive install, please ensure
that all partitions are gracefully shut down prior to initiating a
firmware installation.
-
To determine if a service pack is disruptive, refer to section 3.0 of this
document.
-
Ensure that there are no outstanding serviceable events showing on the
Service Focal Point before starting the firmware installation.
-
Disable call home prior to beginning the firmware installation.
-
Ensure that the HMC is not network connected to an HMC with call home enabled
prior to beginning the firmware installation.
-
If the system and power subsystem firmware installation results in new
serviceable events, ensure they are resolved/closed prior to re-enabling
call home.
-
Call home should be enabled again at the end of the firmware installation.
-
Verify that you have good network connections between the Hardware Management
Console, the managed system and the power subsystem.
You can verify your network connections by running the following HMC
command from an rsh window:
lssysconn -r all
Below is a sample output of the lssysconn command for a single frame 595
system. It shows two connections have "state = no
connection" problems. If "state = no
connection" is shown for any of the components when running the
lssysconn command, contact your support structure for assistance in correcting
the problem before attempting a Licensed Internal code update.
resource_type=sys,type_model_serial_num=9119-595*512884E,sp=primary,ipaddr=192.168.255.250,state=Connected
resource_type=sys,type_model_serial_num=9119-595*512884E,sp=backup,ipaddr=192.168.252.255,state=No
Connection
resource_type=frame,type_model_serial_num=9458-100*918000X,side=a,ipaddr=192.168.253.253,
state=No Connection
resource_type=frame,type_model_serial_num=9458-100*918000X,side=b,ipaddr=192.168.254.251,
state=Connected
Note: Only 575 systems will display multiple components. All
other system types will only return a single line for each managed system.
Systems at Firmware Level SF230_120 or SF230_126
If your system is HMC managed, and is currently at system firmware level
SF230_120 or SF230_126, you may see a failure on upgrades to this SF235
service pack. The failure is due to a timing condition in the SF230_120
or SF230_126 firmware (look for an error log with the SRC B181873C).
If this problem is the cause for your failure, it is recommended you update
to SF230_145 or a later SF230 service pack prior to performing the upgrade
to this SF235 service pack. The update from SF230_120 or SF230_126
to a later SF230 level can be done concurrently.
Important Information for 9117-570 and 9406-570 Systems with 12 or 16
Processors
Installation of the SF235_160 level erroneously sets the maximum number
of partitions on systems with 12 or 16 processors to 80, which will cause
the system to go to Recovery or Incomplete state when the HMC is rebooted.
While this problem is resolved by a concurrent update contained in this
service pack, the recommended method of installation is to quiesce and
power down the managed system prior to installation of the service pack.
Concurrent installation and activation is possible in most cases; however,
it requires that the following instructions be followed explicitly.
Regardless of which method of installation is chosen, the HMC must be rebooted
after the service pack is installed.
Note: These instructions are only applicable to systems that were upgraded
from a prior release level to the SF235_160 level. New systems that were
received with system firmware level SF235_160 installed at the factory
will have the 80 partition limit set but will not require these steps to
be performed to install the service pack concurrently.
Concurrent recovery instructions:
1) Reboot the HMC. The managed system will be in the recovery
state.
2) Recover the partition data using the option to restore the profile
data from the HMC backup data.
3) After the system returns to Operating state, install the service
pack immediately. Do NOT attempt any LPAR management tasks (such
as activate, deactivate, create partitions or change profile definitions).
If the system does not return to the Operating state, concurrent recovery
will not be possible. Do NOT proceed. Schedule a service window
which will allow the update to be installed at power off state.
4) After a message indicating a successful completion of the service
pack installation is received, reboot the HMC again. In the event that
the update fails while attempting to return the managed system to its original
state (indicated by message HSCL0037), then a reboot of the managed system
will be required followed by a reboot of the HMC.
Installing System Firmware using a CD
Note: When attempting to install system firmware from CD media
you may receive an HMC error approximately 10 seconds after starting the
installation. Here are probable causes for this problem:
-
ACT01712E - A failure occurred while copying files from your DVD - Retry
the firmware installation after burning a new CD. We recommend DVD-RAM
or CD-R media to reduce the probability of media errors. We recommend you
do
not use CD-RW media.
-
ACT01724E - The operation failed due to an internal code failure - The
filesystem on the HMC may be too full to copy the firmware images.
From the HMC command line issue a "df" command to view %use of the
filesystems. If the /dev/hda2 file system is nearly 100% full, there is
no space in which to copy the firmware files. For guidance
on how to correct this, contact HMC support.
3.0 Firmware Information
and Description
IBM introduced the Concurrent Firmware Maintenance (CFM) function on p5
systems in system firmware level SF230_126_120, which was released on June
16, 2005. This function supports nondisruptive system firmware service
packs to be applied to the system concurrently (without requiring an IPL
to activate changes).
For systems that are not managed by an HMC, the installation of system
firmware is always disruptive.
Note: The concurrent levels of system firmware may, on occasion,
contain fixes that are known as deferred. These deferred fixes can be installed
concurrently, but will not be activated until the next IPL. Deferred
fixes, if any, will be identified in the "Firmware Update Descriptions"
table of this document. For deferred fixes within a service pack,
only the fixes in the service pack which cannot be concurrently activated
are deferred.
Use the following example as a reference to determine whether your installation
will be concurrent or disruptive.
Note: The file names and service pack levels used in the
following examples are for clarification only, and are not
necessarily levels that have been, or will be released.
System firmware file naming convention:
01SFXXX_YYY_ZZZ
-
XXX is the release level
-
YYY is the service pack level
-
ZZZ is the last disruptive service pack level
NOTE: Values of service pack and last disruptive service pack
level (YYY and ZZZ) are only unique within
a release level (XXX). For example, 01SF235_250_120 and 01SF240_250_200
are different service packs.
An installation is disruptive if:
-
The release levels (XXX) are different.
Example: Currently installed release is SF225, new release is SF230
-
The service pack level (YYY) and the last disruptive service
pack level (ZZZ) are equal.
Example: SF230_120_120 is disruptive, no matter what level of SF230
is currently
installed on the system
-
The service pack level (YYY) currently installed on the system is lower
than the last disruptive service pack level (ZZZ) of the service pack to
be installed.
Example: Currently installed service pack is SF230_120_120 and
new service pack is SF230_152_130
An installation is concurrent if:
-
The service pack level (YYY) is higher than the service pack
level currently installed on your system.
Example: Currently installed service pack is SF230_126_120,
new service pack is SF230_143_120.
Firmware File Information and Update Description
Filename |
Size |
Checksum |
01SF235_185_160.rpm |
14170525 |
42945 |
SF235 |
SF235_185_160 |
Impact: Function Severity:
Hiper
System firmware changes that affect models 590 and 595, other HMC-controlled
servers, and clustered systems:
-
Fixed a problem that was causing error code B1xx100A to be logged when
an HMC was disconnected from a managed system. This problem is much
more likely to occur on managed systems that have two or more HMCs attached,
but it can also be seen on systems with only one HMC attached.
-
Fixed a problem that caused commands involving LEDs to time out on large,
heavily configured systems.
-
A new function was added to system firmware to allow power code downloads
to towers to be enabled and disabled. On eServer systems with a large
number of towers, this allows customers to shorten the downtime after a
system firmware installation by disabling the power code download to the
towers, then enabling it at a convenient time.
System firmware changes that affect specific p5 and i5 systems not in
24 inch racks:
-
Supports Double Data Rate (DDR) PCI adapters in DDR PCI slots in the following
systems: 9111-520, 9131-52A, 9113-550, 9133-55A, 9111-285,
9405-520, and 9406-520. Running a DDR PCI adapter in a DDR PCI slot
in one of these models with a firmware level prior to this one may result
in a potential data error. IBM recommends that you install this level
immediately if using a DDR PCI adapter.
Full DDR adapter performance is not enabled in this level. Full performance
is planned to be enabled in a service pack that will be released in the
future. |
SF235_180_160 |
Impact: Serviceability
Severity: Special Attention
System firmware changes that affect all p5 and i5 systems:
-
DEFERRED The hardware initialization settings were changed
to prevent system crashes at runtime under some circumstances.
-
DEFERRED The initialization settings of the memory buffers
were changed to eliminate spurious checkstops that were causing system
and partition crashes.
-
Fixed a problem that causes the system attention LED to be in the incorrect
state.
-
Fixed a problem that was causing the system attention light to come
on even though no serviceable events had been logged.
-
Fixed a problem that was causing the SMS menus to hang when the boot list
was viewed or changed when two AIX images are on one hard file.
-
Fixed a problem that caused a 11003114 error code to be generated during
power on.
-
Fixed a problem that caused a null pointer in the virtual I/O (VIO) firmware.
-
i5/OS only: Fixed a problem that was preventing an i5/OS partition
from booting from an IOA in a DDR slot.
-
i5/OS only: Fixed a problem that was causing some adapters to fail
to become operational in i5/OS in a DDR (double data rate) slot.
-
i5/OS only: Fixed a problem that was causing incorrect error reporting
for adapters that do not support extended error handling (EEH) when installed
in a DDR slot.
System firmware changes that affect models 590 and 595, other HMC-controlled
servers, and clustered systems:
-
DEFERRED Fixed a problem that prevented a VTERM
session from being opened on the HMC in certain network configurations.
-
Fixed a problem that caused bulk power controller (BPC) connection errors
in clustered systems by increasing the NETC SSL time-out value.
-
Fixed a problem that caused HMC-directed concurrent maintenance actions
to fail with the message "CIM client detected: hard stop or user
intervention. Try again or delay the repair.".
-
Fixed a problem that was causing platform dumps on large, richly-configured
systems to result in an out-of-bounds memory access failure.
-
A change was made to shorten the time to execute DLPAR memory removal operations.
System firmware changes that affect systems that are not HMC-controlled:
-
A timing issue in the firmware was fixed that was causing firmware installations
from the operating system to fail.
System firmware changes that affect the model 570:
-
On a model 570 systems with 12 or 16 processors, the maximum number of
partitions had been erroneously set to 80 in SF235_160; this firmware level
sets the maximum back to 120 partitions for 12 processors and 160 for 16
processors.
-
On the model 570 with three or four processor drawers, fixed a problem
that was causing the system to stop with error code A7004713 when installing
SF235_160 or higher system firmware.
|
SF235_160_160 |
Impact: Function Severity:
Special Attention
New function:
-
On i5 systems, added support for booting from a boot device attached to
an IOP-less adapter.
-
Added support for the installation of two copies of the AIX operating system
on one hard file. This includes support in the SMS menus for booting
from either one.
-
Added support for feature code 1812, the GX Dual-port 4x InfiniBand Host
Channel Adapter, on model 52A systems.
-
Added support for feature code 1811, the GX Dual-port 4x InfiniBand Host
Channel Adapter, on model 575 systems.
-
Added support for moving the CUoD resources from one system to another
system.
-
Added support for the capability to set up a backup shared ethernet so
that the shared ethernet function can fail-over to a standby shared ethernet
if the primary fails. This function is part of the virtual IO server.
-
Added support for redundant service processors with dynamic failover in
models 570, 590, and 595.
-
Added support for modifying the number of On/Off CoD activations during
the active period.
-
Added support for unattended HMC installation over a network, and to back
up full HMC disk images onto a network server.
-
Added support for new models: 9131-52A, 9111-285, 9133-55A, 9115-505.
-
Various enhancements to the ASCII version of the Advanced System Management
Interface (ASMI) menus were made.
Problems resolved:
-
Fixed a problem that was causing the user data in a service processor error
log entry generated by the bulk power controller to be truncated to 2048
bytes.
-
Fixed a problem that caused unnecessary Service Agent calls because SRC
B1816009 was being generated when the white power button was pressed before
the power-on sequence was complete.
-
On model 590 and 595 systems, fixed a problem that was causing DDR II memory
cards in slots C10 and C12 to fail the memory test during a slow-mode boot.
-
Fixed a problem that prevents power on and posts a 11002613 error
code when AC is lost to one power supply. This problem exists only
in SF230 levels of firmware.
-
Fixed a problem that was causing a platform dump to be incomplete under
certain circumstances.
-
Fixed a problem that was causing a hypervisor dump to be corrupted.
-
Fixed a problem that caused the location codes to be incorrect after the
planar is replaced in a pSeries 7311-D20 drawer.
-
The timestamp from the bulk power controller was added into the serviceable
event log entry.
-
Fixed a problem that prevented the "nvunalias" open firmware command from
working.
-
Fixed a problem that kept the physical I/O description field on the HMC
GUI from being updated after a "remove FRU and add FRU" operation.
-
Fixed a problem that caused a service processor dump or a platform dump
and SRC B1817201 or B7004400.
-
Changed the firmware so that a modem attached to a system port will reconfigure
to enable call-in following a power failure.
-
Fixed VPD-related command hangs (such as lsmcode, lsvpd, snap)
-
Fixed several problems associated with firmware installations:
-
SRC B1814008 or B181F131 was generated on reboot
-
A service processor dump occurred during a firmware installation
-
"lsmcode -c" command displayed all zeros for the firmware level on the
T side after an installation
|
4.0
How to Determine Currently Installed Firmware Levels
Instructions for determining the current level of firmware can be found
at http://publib.boulder.ibm.com/eserver/v1r3s/index.jsp?topic=/ipha5/viewexistlevel.htm
5.0 Downloading
the Firmware Package
The firmware is located at the web site
http://www14.software.ibm.com/webapp/set2/firmware/gjsn
Follow the instructions on this web page. You must read and agree to
the license agreement to obtain the firmware packages.
In the drop-down box, choose the entry for your specific machine type
and model.
You may download the individual .rpm and .xml files for
system firmware and power subsystem firmware (if required) from this location
to your server, an ftp server, or a CD-ROM (both files are required).
Make sure the file names have the format 01SF2xx_yyy_zzz, with an extension
of .rpm and .xml before copying them to your server, an ftp server or CD-ROM.
If using a CD-ROM, copy the .rpm and .xml files to the CD-ROM using
a local CD-ROM burner utility. For 9118-575 systems, your server, the ftp
server or CD-ROM must contain both the system firmware and power
subsystem firmware files.
Another method is to download the ISO image SF235_185_BP235_157.iso
and create a CD-ROM to use with your HMC. The CD contains both the system
and power subsystem firmware files.
Note: If your HMC is not internet-connected you will need to download
the new firmware level to a CD-ROM or ftp server.
6.0 Installing the Firmware
The method used to install new firmware will depend on the release level
of firmware which is currently installed on your server. The release level
can be determined by the prefix of the new firmware's filename.
Example: 01SFXXX_YYY_ZZZ
Where XXX = release level
-
If the release level will stay the same (Example: Level 01SF222_075_075
is currently installed and you are attempting to install level 01SF222_081_081)
this is considered an update.
-
If the release level will change (Example: Level 01SF222_081_081 is currently
installed and you are attempting to install level 01SF225_096_096) this
is considered an upgrade.
Instructions for installing firmware updates and upgrades can be found
at
http://publib.boulder.ibm.com/infocenter/eserver/v1r3s/index.jsp?topic=/ipha5/fix_serv_firm_kick.htm
Choose the options that match your server setup, and follow the instructions
provided.
Note: For systems without an HMC, the update and upgrade procedure is
the same.
7.0 Firmware History
SF230 |
SF230_156_120 |
Impact: Function Severity:
Hiper
Two fixes that were deferred in earlier levels are concurrent in
this level:
1. In firmware level SF230_150, there was a deferred fix that
affects all p5 and i5 systems:
HIPER: The initialization settings of the memory buffers
were changed to eliminate spurious checkstops that were causing system
and partition crashes.
In SF230_156, this fix is CONCURRENT.
2. In firmware level SF230_153 (which is also part of ECA 823),
there was a deferred fix that affects model 59x systems:
HIPER: The hardware initialization settings were changed
to fix an incorrect timeout setting in the non-cacheable unit (NCU). The
current settings may cause a system checkstop, which could result in a
system or partition crash. This is also known as the "EMQ hang"
problem.
In SF230_156, this fix is CONCURRENT. Also, the recovery time
for the EMQ hang was improved to benefit HACMP configurations.
System firmware changes that affect all p5 and i5 systems:
-
HIPER: An incorrect initialization setting in the shared memory
interface (SMI) may cause a system checkstop, which could result
in a system or partition crash. This is also known as the "SMI parity error"
issue.
-
HIPER: Fixed a firmware problem that caused the system to
interpret a machine condition as requiring special attention handling,
where no special attention existed. This could result in a system checkstop
(with error codes B181F647 and B110F139). This problem is also known
as the "master attention alone" issue.
System firmware changes that affect the model 575, 59x, other HMC-controlled
servers, and clustered systems:
-
DEFERRED and HIPER: A potential server checkstop issue exists
in clusters using p5 models p575, p590, and p595, when these models are
used to execute compute-intensive applications tuned with the November
Power5 Fortran compiler. Clusters executing applications that are
compiled for optimal performance by utilizing the software pre-fetch function
are exposed to a server checkstop (B1xxE500). Hardware initialization settings
were changed to fix this problem and the performance tools modified
to take these new settings into account.
-
HIPER On systems with a high performance switch (HPS) network
adapter installed, fixed a problem that caused a checkstop when memory
was moved from a partition that did not own an HPS network adapter.
-
A problem was fixed that prevented I/O towers from being concurrently added
to i5 systems.
-
A problem was fixed that was preventing partitions with large amounts of
memory from booting successfully.
-
The firmware was changed so that the time it takes to remove a large amount
of memory from a partition using a DLPAR (dynamic LPAR) operation is reduced.
-
A problem was fixed that was causing enhanced error handling (EEH) error
codes to be erroneously generated on 7040-61D I/O drawers when certain
adapter card configurations were heavily stressed by the application code.
System firmware changes that affect p5 systems not in 24 inch racks:
-
On p5 systems that are not managed by an HMC, the timeout for firmware
installations performed by the operating system ("in-band" installations)
was increased.
|
SF230_150_120 |
Impact: Serviceability
Severity: Special Attention
Attention: An IPL is required to activate a deferred fix, the
system must be powered off via the HMC, (i.e. HMC state=Power OFF) and
then powered back on.
-
DEFERRED Changed the initialization settings of the memory buffers
to eliminate spurious checkstops that were causing system and partition
crashes.
-
DEFERRED On model 590 and 595 systems, fixed a problem that
was causing DDR II memory cards in slots C10 and C12 to fail the memory
test during a slow-mode boot.
-
DEFERRED Fixed a problem that was not allowing the system
enclosure serial number to be rewritten using the ASMI menus.
-
DEFERRED Fixed a problem that causes the default boot list
and the stored boot list to be swapped in the system management services
(SMS) firmware when booting an AIX or Linux partition.
-
Several problems were fixed that caused a failure to boot with SRCs B1817201,
C1001014 and/or C1001020.
-
On an HMC, fixed a problem that caused a blank screen when reopening a
VTERM after closing it.
-
Fixed a problem that was causing a platform dump to be incomplete under
certain circumstances.
-
Fixed a problem that caused a "no connection" state between the HMC and
the service processor after the service processor attempted a dump operation.
-
Added support for ARP (address request protocol) to the System Management
Services (SMS) firmware for AIX and Linux partitions.
-
Fixed a problem in the server firmware that was allowing the HMC to allocate
more memory to a partition than was available.
|
SF230_147_120 |
Impact: Serviceability
Severity: Special Attention
-
Fixed a problem that caused system processors to get into a locked state.
-
Changed the initialization settings of the memory buffers to eliminate
spurious checkstops that were causing system and partition crashes.
|
SF230_145_120 |
Impact: Serviceability
Severity: Special Attention
-
Fixed a problem on i5 systems with 5074 I/O towers that causes a partition
to hang with SRC B6000255 when an I/O adapter in the 5074 is moved using
dynamic LPAR.
-
Fixed a problem on i5 and p5 systems that causes a continuous stream of
phantom interrupts on partitions with shared processors.
|
SF230_143_120 |
Impact: Serviceability
Severity: Special Attention
Attention: An IPL is required to activate a deferred fix, the
system must be powered off via the HMC, (i.e. HMC state=Power OFF) and
then powered back on.
-
DEFERRED On model 575 and 59x systems in which an IBM High
Performance Switch (HPS) is installed, fixed a problem that was causing
an invalid high performance switch adapter failure to be reported after
a switch failure.
-
DEFERRED On model SR110000 systems only, fixed a problem that
was causing the I/O in the CEC not to show up after an IPL.
-
DEFERRED On systems that are managed by an HMC, a problem
was fixed that was causing concurrent firmware update to fail with error
code ACT01724 on the HMC.
-
DEFERRED Fixed a problem involving correctable and uncorrectable
memory errors that may have resulted in memory being deconfigured during
a slow mode IPL on 9119-59x systems with F/C 7814 (4 GB memory cards) installed.
-
Support for 16-way model 575 systems was added to the SF230 release.
-
Fixed a problem that was causing the firmware to erroneously report a failure
of the High Performance Switch (HPS) adapter card (with error code B181F62A)
in a 16-way model 575 system.
-
On model 59x systems, a memory leak was fixed that could cause the system
to reset during boot.
-
Fixed false error code B1812033 introduced in code level SF230_120 on all
p5 and i5 systems model 570 and lower. The B1812033 error code may still
be valid on 575 and 59x systems.
-
Fixed intermittent boot problem introduced in code level SF230_120 on all
p5 and i5 systems model 550 and lower. Error codes related to this boot
problem include B1701004, B181F12E or B150F22A.
-
On model 575 and 59x systems in which an IBM High Performance Switch (HPS)
is installed, a problem in the system firmware was fixed that was causing
duplicate errors for the same problem to be reported in the service processor
error log and the HPS Network Manager error log.
-
On model 575 and 59x systems in which an IBM High Performance Switch (HPS)
is installed, a problem in the system firmware was fixed that was causing
some switch network interface (SNI) adapters to fail a wrap test.
-
On systems that are managed by an HMC, fixed a problem that was preventing
some types of errors that were logged in the service processor's error
log from being sent to the HMC.
-
Fixed a problem that caused a very early reset/reload of the service processor
with error codes of B1817201, B1817209 or similar after a firmware update.
-
On systems that shipped with a firmware level that begins with SF210, a
problem was fixed that was causing the firmware installation to the T side
to fail with error code B1817201.
-
Fixed a problem that was causing platform system dumps to be corrupted.
-
Fixed a problem that was causing concurrent firmware maintenance to fail.
|
SF230_126_120 |
Impact: Function Severity:
Hiper
-
Fixed a problem that causes the media bay to lose power, which makes the
DVD drives in the bay inoperable on 9117-570 and 9406-570 systems.
-
Fixed most problems introduced in SF230_120 that causes the white power
on/off button to intermittently fail to boot the system, terminating with
error codes B181F12E, B1701004 or B150F22A, on 9111-520, 9113-550, 9405-520,
9406-520 and 9406-550 systems.
-
Fixed a problem that causes various types of planar and RIO cable failures
in the 7040-61D I/O subsystem to be reported on 9118-575, 9119-590, 9119-595
and 9406-595.
|
SF230_120_120 |
Impact: Function Severity:
Hiper
New function:
-
Adds code to notify the user when the VPD card is not in its original system,
and to prevent that system from booting.
-
Adds support for i5/OS hosting virtual Linux and AIX partitions on i5 systems
that are not managed by an HMC.
-
Adds support for F/C 7910 on model 9118-575 systems the switch network
interface adapter, which provides the interface to the pSeries high
performance switch (HPS).
-
Adds support for F/C 7817 on 9119-590, 9119-595, and 9406-595 systems,
the switch network interface (SNI) adapter, which provides the interface
to the pSeries high performance switch (HPS).
-
Adds support for concurrent firmware maintenance on systems managed by
an HMC.
-
Adds support for 32GB memory cards on 9119-590, 9119-595, and 9406-595
systems.
-
Adds support for F/C 7894, 8GB (4x2GB) feature (2GB DDR2 DIMMs, CCIN 30F3)
on machine type 9117-570.
Problems resolved:
-
LEDs on GX bus adapter cards remain on after the node is powered off for
9119-590, 9119-595, and 9406-595 systems.
-
The service processor is not able to place a "call home" through a modem.
-
On systems 9118-575, 9119-590, 9119-595, and 9406-595: a firmware upgrade
from SF222_075 to SF225_096 fails with error code ACT01724 on the HMC.
-
Fixed a problem that causes the default boot list and the stored boot list
to be swapped in the system management services (SMS) code when booting
an AIX or Linux partition.
-
Fixed a highly intermittent problem that causes the service processor to
perform a dump when an SRC is displayed on the control panel.
-
On 9118-575, 9119-590, 9119-595, and 9406-595 systems, updates the
firmware so that the system will continue to boot when certain types of
failures occur on bus adapter cards.
-
Fixed a problem on 9118-575, 9119-590, 9119-595, and 9406-595 systems
which caused a reboot to fail with error code B7006900 under certain conditions.
-
Fixed a problem with moving a CD-ROM device between two logical partitions
using DLPAR commands on the HMC.
-
On 9117-570 and 9406-570 systems: Fixed a problem a that causes a
DMA_ERR with error code 1000 0003 on the integrated Ethernet port.
-
DS8000 storage subsystem: multiple firmware fixes.
-
Fixed a problem that causes the system clock to revert to December 31,
1969 and the system to crash with error code B7000103.
-
On 9119-590 systems, fixed a problem that keeps large configurations (12
or more I/O drawers with both planars installed) from booting.
-
Fixed a problem that prevents the 'lscfg -vp' command from reporting platform-specific
data on all p5 systems.
-
Fixed a problem that intermittently causes a partition or the system to
hang when the lsvpd or lscfg command is run on all p5 systems. Also,
'the lsmcode' command may return "NOT DETERMINABLE".
-
If two power supplies are installed, the system may fail to power on if
one power supply fails in the 9110-510, 9111-520, 9113-550, 9117-570, 9123-xxx,
9124-xxx, 9405-520, 9406-520, 9406-550, 9406-570 systems.
-
Fixed a problem that prevents a virtual SCSI client from connecting to
a virtual SCSI server adapter on 9118-575, 9119-590, and 9119-595 systems.
|
SF225 |
SF225_096_096 |
Impact: Function Severity: Hiper
-
Fixed a problem in the service processor firmware that made it look like
the T-side image was being lost after a "reset to factory configuration"
was done using the ASMI menus.
|
SF225_080_080 |
Impact: New
Severity: New
-
Added support for 9118-575, 9110-510, and 9123-710.
|
SF222 |
SF222_081_081 |
Impact: Function Severity: Hiper
-
Fixed a problem that caused FSCSI errors to show up erroneously in the
AIX error log when an I/O adapter failed.
-
Fixed a problem that caused the processor runtime diagnostics to call out
the wrong DIMM (or other memory component) when a memory failure occurred.
-
Fixed a problem that caused a platform dump to run out of storage space.
-
Fixed a problem that prevented the LEDs on I/O drawers from identifying
or "rolling up" to the frame enclosure LED.
-
Fixed a problem that caused the service processor to generate error log
entries every few seconds when attempting to service a recoverable CEC
hardware error on systems that have processors with no memory associated
with them.
|
SF222_075_075 |
Impact: Function Severity:
Hiper
-
Fixed a problem with the AMSI menu option that allows system VPD keywords
to be set.
-
Fixed a problem that kept the system from continuing to boot when an 8GB
memory DIMM is deallocated because an uncorrectable error was generated
by the DIMM during boot.
-
Fixed a problem that caused a partition's time to appear to drift (approximately
15 seconds/month) following a system IPL.
-
Support for partitions running i5/OS on p5 systems was added.
-
Fixed a problem that caused the default boot list and the stored boot list
in the SMS menus to be swapped.
|
SF222_071_071 |
Impact: New
Severity: New
-
Added support for systems 9119-590, 9119-595, and 9406-595.
|
SF220 |
SF220_051_051 |
Impact: Function Severity: Hiper
-
Fixed a problem that kept feature code 1827, a UPS sense cable, from being
detected.
|
SF220_049_049 |
Impact: Function Severity:
Hiper
-
Fixed a problem that kept the serial ports on the processor drawer from
functioning in 9117-570 and 9406-570 systems with multiple processor drawers.
-
Fixed a problem that kept the user from accessing the advanced system management
interface (ASMI) via the web interface.
|
SF220_046_046 |
Impact: Function Severity:
Hiper
-
Fixed a problem that caused the kept the service processor from getting
to standby when an Ethernet cable was not plugged into it.
|
SF220_045_045 |
Impact: Function Severity:
Hiper
-
Various corrections and updates.
|
SF220_043_043 |
Impact: New
Severity: New
-
Added support for new models: 9111-520, 9113-550, 9406-550, 9124-720,
and 9117-570.
|
8.0 Change History
DATE |
Description |
Sept 28, 2006 |
Added information in Section 2.0 concerning memory usage when upgrading
firmware. |