<?xml version="1.0" encoding="ISO-8859-1"?>
<fixpacks>

  <fixpack name="01SF230_150_120">
   <base>01SF230_145_120</base>
    <update name="GEN001">
	<description_text>Several problems were fixed that caused a failure to boot with SRCs B1817201, C1001014 and/or C1001020.</description_text>
    </update>

       <update name="493843">
      <description_text>On an HMC, fixed a problem that caused a blank screen when reopening a VTERM after closing it. 
</description_text> 
      <conclusion_text>LIC code updated.</conclusion_text>
      <circumvention_text>N/A</circumvention_text>
    </update>
    <update name="510921">
      <description_text>On model 590 and 595 systems, fixed a problem that was causing DDR II memory cards in slots C10 and C12 to fail the memory test during a slow-mode boot.</description_text> 
      <conclusion_text>LIC code updated.</conclusion_text>
      <circumvention_text>N/A</circumvention_text>
    </update>
    <update name="517985">
      <description_text>Fixed a problem that was causing a platform dump to be incomplete under certain circumstances.</description_text> 
      <conclusion_text>LIC code updated.</conclusion_text>
      <circumvention_text>N/A</circumvention_text>
    </update>
<update name="518930">
      <description_text>Fixed a problem that was not allowing the system enclosure serial number to be rewritten using the ASMI menus.
  </description_text> 
      <conclusion_text>LIC code updated.</conclusion_text>
      <circumvention_text>N/A</circumvention_text>
    </update>

<update name="520148">
      <description_text>Changed the initialization settings of the memory buffers to eliminate spurious checkstops that were causing system and partition crashes.  </description_text> 
      <conclusion_text>LIC code updated.</conclusion_text>
      <circumvention_text>N/A</circumvention_text>
    </update>
    <update name="521087">
      <description_text>Fixed a problem that caused a "no connection" state between the HMC and the service processor after the service processor attempted a dump operation. </description_text> 
      <conclusion_text>LIC code updated.</conclusion_text>
      <circumvention_text>N/A</circumvention_text>
    </update>
<update name="502463">
      <description_text>Added support for ARP (address request protocol) to the System Management Services (SMS) firmware for AIX and Linux partitions.  </description_text> 
      <conclusion_text>LIC code updated.</conclusion_text>
      <circumvention_text>N/A</circumvention_text>
    </update>
    <update name="493256">
      <description_text>Corrects a problem that causes the default boot list and the stored boot list to be swapped in the system management services (SMS) firmware when booting an AIX or Linux partition. </description_text> 
      <conclusion_text>LIC code updated.</conclusion_text>
      <circumvention_text>N/A</circumvention_text>
    </update>
<update name="518192">
      <description_text>Fixed a problem in the server firmware that was allowing the HMC to allocate more memory to a partition than was available. </description_text> 
      <conclusion_text>LIC code updated.</conclusion_text>
      <circumvention_text>N/A</circumvention_text>
    </update>
  </fixpack>

  <fixpack name="01SF230_145_120">
    <base>01SF230_143_120</base>
    <update name="512999">
      <description_text>On i5 systems with 5074 I/O towers, a problem is corrected that causes a partition to hang with SRC B6000255 when an I/O adapter in the 5074 is moved using the dynamic LPAR function.</description_text> 
      <conclusion_text>LIC code updated.</conclusion_text>
      <circumvention_text>N/A</circumvention_text>
    </update>
    <update name="515599">
      <description_text> On i5 and p5 systems, a problem is corrected that caused a continuous stream of phantom interrupts on partitions with shared processors.</description_text> 
      <conclusion_text>LIC code updated.</conclusion_text>
      <circumvention_text>N/A</circumvention_text>
    </update>
  </fixpack>

  <fixpack name="01SF230_143_120">
    <base>01SF230_126_120</base>
    <update name="513493">
      <description_text>DEFERRED   Corrects a problem involving correctable and uncorrectable memory errors that may have resulted in memory being deconfigured during a slow mode IPL on 9119 59x systems with feature code 7814 (4 GB memory cards) installed. </description_text> 
      <conclusion_text>LIC code updated to correct a timing issue.</conclusion_text>
      <circumvention_text>N/A</circumvention_text>
    </update>
    <update name="505489">
      <description_text>DEFERRED   On model 575 and 59x systems in which an IBM High Performance Switch (HPS) is installed, a problem was fixed that was causing an invalid high performance switch adapter failure to be reported after a switch failure.  When applying the service pack that contains this fix, a full IPL is required to activate the fix.</description_text>
      <conclusion_text>LIC code updated.</conclusion_text>
      <circumvention_text>N/A</circumvention_text>
    </update>
    <update name="509124">
      <description_text>DEFERRED   On model SR110000 systems only, a problem was fixed that was causing the I/O in the processor subsystem not to show up after an IPL.  When applying the service pack that contains this fix, a full IPL is required to activate the fix. </description_text>
      <conclusion_text>LIC code updated.</conclusion_text>
      <circumvention_text>N/A</circumvention_text>
    </update>
    <update name="MB01110">
      <description_text>DEFERRED   On systems that are managed by an HMC, a problem was fixed that was causing concurrent firmware update to fail with error code ACT01724 on the HMC.  When applying the service pack that contains this fix, a full IPL is required to activate the fix. </description_text>
      <conclusion_text>LIC code updated.</conclusion_text>
      <circumvention_text>N/A</circumvention_text>
    </update>
    <update name="511324">
      <description_text>Support for 16-way model 575 systems was added to the 01SF230 release.</description_text>
      <conclusion_text>LIC code updated.</conclusion_text>
      <circumvention_text>N/A</circumvention_text>
    </update>
    <update name="508022">
      <description_text>Corrects a problem that was causing the firmware to erroneously report a failure of the High Performance Switch (HPS) adapter card (with error code B181F62A) in a 16-way model 575 system. </description_text>
      <conclusion_text>LIC code updated.</conclusion_text>
      <circumvention_text>N/A</circumvention_text>
    </update>
    <update name="505894">
      <description_text> On model 59x systems, a memory leak was fixed that could cause the system to reset during boot.</description_text>
      <conclusion_text>LIC code updated.</conclusion_text>
      <circumvention_text>N/A</circumvention_text>
    </update>
    <update name="511015">
      <description_text>Fixes false error code B1812033 introduced in code level 01SF230_120_120 on all p5 and i5 9123-xxx, model 520, model 550, and model 570 systems.  The B1812033 error code may still be valid on 575 and  59x systems. </description_text>
      <conclusion_text>LIC code updated.</conclusion_text>
      <circumvention_text>N/A</circumvention_text>
    </update>
    <update name="509002">
      <description_text>Fixes intermittent boot problem introduced in code level 01SF230_120_120 on all p5 and i5 9123-xxx, model 520, and model 550 systems.  Error codes related to this boot problem include B1701004, B181F12E and B150F22FA.</description_text>
      <conclusion_text>LIC code updated.</conclusion_text>
      <circumvention_text>N/A</circumvention_text>
    </update>
    <update name="509200">
      <description_text>On model 575 and 59x systems in which an IBM High Performance Switch (HPS) is installed, a problem in the system firmware was fixed that was causing duplicate errors for the same problem to be reported in the service processor error log and the HPS Network Manager error log.    </description_text>
      <conclusion_text>LIC code updated.</conclusion_text>
      <circumvention_text>N/A</circumvention_text>
    </update>
    <update name="505549">
      <description_text> On model 575 and 59x systems in which an IBM High Performance Switch (HPS) is installed, a problem in the system firmware was fixed that was causing some switch network interface (SNI) adapters to fail a wrap test.  </description_text>
      <conclusion_text>LIC code updated.</conclusion_text>
      <circumvention_text>N/A</circumvention_text>
    </update>
    <update name="505506">
      <description_text>On systems that are managed by an HMC, a problem was fixed that was preventing some types of errors that were logged in the service processor's error log from being sent to the HMC. </description_text>
      <conclusion_text>LIC code updated.</conclusion_text>
      <circumvention_text>N/A</circumvention_text>
    </update>
    <update name="502657">
      <description_text> A problem was fixed that caused a very early reset/reload of the service processor with error codes of B1817201, B1817209 and similar after a firmware update. </description_text>
      <conclusion_text>LIC code updated.</conclusion_text>
      <circumvention_text>N/A</circumvention_text>
    </update>
    <update name="503399">
      <description_text>On systems that shipped with a firmware level that begins with 01SF210, a problem was fixed that was causing the firmware installation to the T side to fail with error code B1817201.
 </description_text>
      <conclusion_text>LIC code updated.</conclusion_text>
      <circumvention_text>N/A</circumvention_text>
    </update>
    <update name="509891">
      <description_text> A problem was fixed that was causing platform system dumps to be corrupted. </description_text>
      <conclusion_text>LIC code updated.</conclusion_text>
      <circumvention_text>N/A</circumvention_text>
    </update>
    <update name="513650">
      <description_text> A problem was fixed that was causing concurrent firmware maintenance to fail. </description_text>
      <conclusion_text>LIC code updated.</conclusion_text>
      <circumvention_text>N/A</circumvention_text>
    </update>
  </fixpack>

  <fixpack name="01SF230_126_120">
    <base>01SF230_120_120</base>
    <update name="MB01102">
      <description_text>p5 and i5 model 570: Media bay looses power, which makes the DVD drives in the bay inoperable.</description_text>
      <conclusion_text>LIC code updated.</conclusion_text>
      <circumvention_text>N/A</circumvention_text>
    </update>
    <update name="MB01103">
      <description_text>On 9111-520, 9113-550, 9405-520, 9406-520, and 9406-550 systems, white button intermittently fails to power on the system. SRC B181F12E, B1701004, or B150F22A is encountered.
</description_text>
      <conclusion_text>LIC code updated to correct a timing issue.</conclusion_text>
      <circumvention_text>None.</circumvention_text>
    </update>
  </fixpack>
  <fixpack name="01SF230_120_120">
    <base>01SF225_096_096</base>
    <update name="NF11C">
      <description_text>Adds support for 1.9 GHz processors on i5 Model 570</description_text>
      <conclusion_text>New function.</conclusion_text>
      <circumvention_text>None.</circumvention_text>
    </update>
    <update name="NF133">
      <description_text>Adds code to notify the user when the VPD card is not in its original system, and to prevent that system from booting.</description_text>
      <conclusion_text>New function.</conclusion_text>
      <circumvention_text>None.</circumvention_text>
    </update>
    <update name="NF284">
      <description_text>Adds support for i5/OS hosting virtual Linux and AIX partitions on i5 systems that are not managed by an HMC.</description_text>
      <conclusion_text>New function.</conclusion_text>
      <circumvention_text>None.</circumvention_text>
    </update>
    <update name="NFD9U">
      <description_text>Adds support for F/C 7910 on model 575 systems the switch network interface (SNI) adapter, which provides the interface to the pSeries high performance switch (HPS).</description_text>
      <conclusion_text>New function.</conclusion_text>
      <circumvention_text>None.</circumvention_text>
    </update>
    <update name="NFDAP">
      <description_text>Adds support for F/C 7817 on models 590 and 595, the switch network interface (SNI) adapter, which provides the interface to the pSeries high performance switch (HPS).</description_text>
      <conclusion_text>New function.</conclusion_text>
      <circumvention_text>None.</circumvention_text>
    </update>
    <update name="NFEF2">
      <description_text>Adds support for concurrent firmware maintenance on systems managed by an HMC.</description_text>
      <conclusion_text>New function.</conclusion_text>
      <circumvention_text>None.</circumvention_text>
    </update>
    <update name="NFGT6">
      <description_text>Adds support for 32GB memory cards on models 590 and 595.</description_text>
      <conclusion_text>New function.</conclusion_text>
      <circumvention_text>None.</circumvention_text>
    </update>

    <update name="488715">
      <description_text>p5 and i5 models 590 and 595:  LEDs on GX bus adapter cards remain on after the node is powered off.</description_text>
      <conclusion_text>LIC code updated.</conclusion_text>
      <circumvention_text>None.</circumvention_text>
    </update>

    <update name="492346">
      <description_text>The service processor is not able to place a &quot;call home&quot; through a modem.</description_text>
      <conclusion_text>LIC code updated to correct the data stream sent.</conclusion_text>
      <circumvention_text>None.</circumvention_text>
    </update>

    <update name="495027">
      <description_text>On model 575, and models 590 and 595:  a firmware upgrade from SF222_075 to SF225_096 fails with error code ACT01724 on the HMC.</description_text>
      <conclusion_text>LIC code updated</conclusion_text>
      <circumvention_text>None.</circumvention_text>
    </update>

    <update name="493256">
      <description_text>Corrects a problem that causes the default boot list and the stored boot list to be swapped in the system management services (SMS) code when booting an AIX or Linux partition.</description_text>
      <conclusion_text>LIC code updated</conclusion_text>
      <circumvention_text>None.</circumvention_text>
    </update>

    <update name="490599">
      <description_text>Corrects a highly intermittent problem that causes the service processor to perform a dump when an SRC is displayed on the control panel.</description_text>
      <conclusion_text>LIC code updated.</conclusion_text>
      <circumvention_text>None.</circumvention_text>
    </update>

    <update name="MB01054">
      <description_text>On model 590 and 595 systems, updates the firmware so that the system will continue to boot when certain types of failures occur on bus adapter cards.</description_text>
      <conclusion_text>LIC code updated.</conclusion_text>
      <circumvention_text>Replace the failing hardware.</circumvention_text>
    </update>

    <update name="501138">
      <description_text>Corrects a problem on model 590 and 595 systems which caused a reboot to fail with error code B7006900 under certain conditions.</description_text>
      <conclusion_text>LIC code updated.</conclusion_text>
      <circumvention_text>Power down system and re-IPL. If the problem does not recreate after the power cycle, then this problem is resolved. Otherwise, debug B7006900 by the normal means.</circumvention_text>
    </update>

    <update name="MB00918">
      <description_text>Corrects a problem with moving a CD-ROM device between two logical partitions using DLPAR commands on the HMC.</description_text>
      <conclusion_text>LIC code updated.</conclusion_text>
      <circumvention_text>None.</circumvention_text>
    </update>

    <update name="500832">
      <description_text>p5 and i5 model 570:  Corrects a problem a that causes a DMA_ERR with error code 10000003 on the integrated Ethernet port.</description_text>
      <conclusion_text>LIC code updated.</conclusion_text>
      <circumvention_text>None.</circumvention_text>
    </update>

    <update name="DMULT">
      <description_text>DS8000 storage subsystem:  multiple firmware fixes.</description_text>
      <conclusion_text>LIC code updated.</conclusion_text>
      <circumvention_text>None.</circumvention_text>
    </update>

    <update name="MB01015">
      <description_text>Corrects a problem that causes  the system clock to revert to December 31, 1969 and the system to crash with error code B7000103.</description_text>
      <conclusion_text>LIC code updated.</conclusion_text>
      <circumvention_text>None.</circumvention_text>
    </update>

    <update name="495212">
      <description_text>On model 590 systems, corrects a problem that keeps large configurations (12 or more I/O drawers with both planars installed) from booting.</description_text>
      <conclusion_text>Updated LIC to allocate more memory for certain processes.</conclusion_text>
      <circumvention_text>None.</circumvention_text>
    </update>


  </fixpack>