01SF230_143_120
On i5 systems with 5074 I/O towers, a problem is corrected that causes a partition to hang with SRC B6000255 when an I/O adapter in the 5074 is moved using the dynamic LPAR function.
LIC code updated.
N/A
On i5 and p5 systems, a problem is corrected that caused a continuous stream of phantom interrupts on partitions with shared processors.
LIC code updated.
N/A
01SF230_126_120
DEFERRED Corrects a problem involving correctable and uncorrectable memory errors that may have resulted in memory being deconfigured during a slow mode IPL on 9119 59x systems with feature code 7814 (4 GB memory cards) installed.
LIC code updated to correct a timing issue.
N/A
DEFERRED On model 575 and 59x systems in which an IBM High Performance Switch (HPS) is installed, a problem was fixed that was causing an invalid high performance switch adapter failure to be reported after a switch failure. When applying the service pack that contains this fix, a full IPL is required to activate the fix.
LIC code updated.
N/A
DEFERRED On model SR110000 systems only, a problem was fixed that was causing the I/O in the processor subsystem not to show up after an IPL. When applying the service pack that contains this fix, a full IPL is required to activate the fix.
LIC code updated.
N/A
DEFERRED On systems that are managed by an HMC, a problem was fixed that was causing concurrent firmware update to fail with error code ACT01724 on the HMC. When applying the service pack that contains this fix, a full IPL is required to activate the fix.
LIC code updated.
N/A
Support for 16-way model 575 systems was added to the 01SF230 release.
LIC code updated.
N/A
Corrects a problem that was causing the firmware to erroneously report a failure of the High Performance Switch (HPS) adapter card (with error code B181F62A) in a 16-way model 575 system.
LIC code updated.
N/A
On model 59x systems, a memory leak was fixed that could cause the system to reset during boot.
LIC code updated.
N/A
Fixes false error code B1812033 introduced in code level 01SF230_120_120 on all p5 and i5 9123-xxx, model 520, model 550, and model 570 systems. The B1812033 error code may still be valid on 575 and 59x systems.
LIC code updated.
N/A
Fixes intermittent boot problem introduced in code level 01SF230_120_120 on all p5 and i5 9123-xxx, model 520, and model 550 systems. Error codes related to this boot problem include B1701004, B181F12E and B150F22FA.
LIC code updated.
N/A
On model 575 and 59x systems in which an IBM High Performance Switch (HPS) is installed, a problem in the system firmware was fixed that was causing duplicate errors for the same problem to be reported in the service processor error log and the HPS Network Manager error log.
LIC code updated.
N/A
On model 575 and 59x systems in which an IBM High Performance Switch (HPS) is installed, a problem in the system firmware was fixed that was causing some switch network interface (SNI) adapters to fail a wrap test.
LIC code updated.
N/A
On systems that are managed by an HMC, a problem was fixed that was preventing some types of errors that were logged in the service processor's error log from being sent to the HMC.
LIC code updated.
N/A
A problem was fixed that caused a very early reset/reload of the service processor with error codes of B1817201, B1817209 and similar after a firmware update.
LIC code updated.
N/A
On systems that shipped with a firmware level that begins with 01SF210, a problem was fixed that was causing the firmware installation to the T side to fail with error code B1817201.
LIC code updated.
N/A
A problem was fixed that was causing platform system dumps to be corrupted.
LIC code updated.
N/A
A problem was fixed that was causing concurrent firmware maintenance to fail.
LIC code updated.
N/A
01SF230_120_120
p5 and i5 model 570: Media bay looses power, which makes the DVD drives in the bay inoperable.
LIC code updated.
N/A
On 9111-520, 9113-550, 9405-520, 9406-520, and 9406-550 systems, white button intermittently fails to power on the system. SRC B181F12E, B1701004, or B150F22A is encountered.
LIC code updated to correct a timing issue.
None.
01SF225_096_096
Adds support for 1.9 GHz processors on i5 Model 570
New function.
None.
Adds code to notify the user when the VPD card is not in its original system, and to prevent that system from booting.
New function.
None.
Adds support for i5/OS hosting virtual Linux and AIX partitions on i5 systems that are not managed by an HMC.
New function.
None.
Adds support for F/C 7910 on model 575 systems the switch network interface (SNI) adapter, which provides the interface to the pSeries high performance switch (HPS).
New function.
None.
Adds support for F/C 7817 on models 590 and 595, the switch network interface (SNI) adapter, which provides the interface to the pSeries high performance switch (HPS).
New function.
None.
Adds support for concurrent firmware maintenance on systems managed by an HMC.
New function.
None.
Adds support for 32GB memory cards on models 590 and 595.
New function.
None.
p5 and i5 models 590 and 595: LEDs on GX bus adapter cards remain on after the node is powered off.
LIC code updated.
None.
The service processor is not able to place a "call home" through a modem.
LIC code updated to correct the data stream sent.
None.
On model 575, and models 590 and 595: a firmware upgrade from SF222_075 to SF225_096 fails with error code ACT01724 on the HMC.
LIC code updated
None.
Corrects a problem that causes the default boot list and the stored boot list to be swapped in the system management services (SMS) code when booting an AIX or Linux partition.
LIC code updated
None.
Corrects a highly intermittent problem that causes the service processor to perform a dump when an SRC is displayed on the control panel.
LIC code updated.
None.
On model 590 and 595 systems, updates the firmware so that the system will continue to boot when certain types of failures occur on bus adapter cards.
LIC code updated.
Replace the failing hardware.
Corrects a problem on model 590 and 595 systems which caused a reboot to fail with error code B7006900 under certain conditions.
LIC code updated.
Power down system and re-IPL. If the problem does not recreate after the power cycle, then this problem is resolved. Otherwise, debug B7006900 by the normal means.
Corrects a problem with moving a CD-ROM device between two logical partitions using DLPAR commands on the HMC.
LIC code updated.
None.
p5 and i5 model 570: Corrects a problem a that causes a DMA_ERR with error code 10000003 on the integrated Ethernet port.
LIC code updated.
None.
DS8000 storage subsystem: multiple firmware fixes.
LIC code updated.
None.
Corrects a problem that causes the system clock to revert to December 31, 1969 and the system to crash with error code B7000103.
LIC code updated.
None.
On model 590 systems, corrects a problem that keeps large configurations (12 or more I/O drawers with both planars installed) from booting.
Updated LIC to allocate more memory for certain processes.
None.