Power5 Firmware

Applies to:  i5, OpenPower and p5 Servers

This document provides information about the installation of Licensed Machine or Licensed Internal Code, which is sometimes referred to generically as microcode or firmware.


Contents


1.0 Systems Affected

This package provides new firmware for i5, OpenPower and p5 Servers only.  Do not use on any other systems.

For 9119-590/595 and 9406-595 systems, if your current firmware level is at release level SF225 or lower, then the installation of this firmware level (including HMC, system firmware and power code) must be completed by your IBM Service Representative (SSR).  Please contact your IBM SSR and request ECA 823.


2.0 Cautions and Important Notes

The backleveling of firmware from any given release level to an earlier release level is not supported on Power5 systems. If you feel that it is necessary to backlevel the firmware on your system to an earlier release level, please contact your next level of support.

For systems that are managed by an HMC

Attention:  Before installing firmware on an HMC managed system: Note: Only 590, 595 and 575 systems will display multiple components. All other system types will only return a single line for each managed system.

Attention:  (Applicable to 9119-590 and 595, 9406-595 and 9118-575 systems only) After installing the System and/or Power Subsystem Firmware, proceed to the HMC console and rebuild the managed server and/or frame using the following procedure:

1. If System Firmware was just installed then reset the connection to the server:

From the "Navigation Area" window pane on the HMC Console:

Next, from the "Server and Partition: Frame Management" window pane: 2. If Power Subsystem Firmware was just installed then reset the connection to the frame:

From the "Navigation Area" window pane on the HMC Console:

Next, from the "Server and Partition: Frame Management" window pane: 3. If BOTH the System Firmware and the Power Subsystem Firmware were just installed then reset the connections to both the server and the frame using steps 1) and 2) above after both sets of firmware have been loaded.

Note:  When attempting to install system firmware from CD media you may receive an HMC error approximately 10 seconds after starting the installation. Here are probable causes for this problem:


3.0 Firmware Information and Description

IBM introduced the Concurrent Firmware Maintenance (CFM) function on p5 systems in system firmware level 01SF230_126_120, which was released on June 16, 2005.  This function supports nondisruptive system firmware service packs to be applied to the system concurrently (without requiring an IPL to activate changes).

For systems that are not managed by an HMC, the installation of system firmware is always disruptive.

Note:  The concurrent levels of system firmware may, on occasion, contain fixes that are known as deferred. These deferred fixes can be installed concurrently, but will not be activated until the next IPL.  Deferred fixes, if any, will be identified in the "Firmware Update Descriptions" table of this document.  For deferred fixes within a service pack, only the fixes in the service pack which cannot be concurrently activated are deferred.

Use the following example as a reference to determine whether your installation will be concurrent or disruptive.

 System firmware naming convention:

     01SFXXX_YYY_ZZZ

Disruptive installation rules: Example:  Currently installed release is 01SF225, new release is 01SF230
  Example:  01SF230_120_120
 

Concurrent installation rules:


Example: Currently installed firmware level is 01SF230_126_120, new firmware level is 01SF230_143_120.
 

Firmware File Information and Update Description
 

Filename Size Checksum
01SF230_145_120.rpm 13191254 16853
 
01SF230
01SF230_145_120 Impact:  Serviceability        Severity:  Special Attention
  • Fixed a problem on i5 systems with 5074 I/O towers that causes a partition to hang with SRC B6000255 when an I/O adapter in the 5074 is moved using dynamic LPAR.
  • Fixed a problem on i5 and p5 systems that causes a continuous stream of phantom interrupts on partitions with shared processors.
01SF230_143_120 Impact:  Serviceability        Severity:  Special Attention

Attention: An IPL is required to activate a deferred fix, the system must be powered off via the HMC, (i.e. HMC state=Power OFF) and then powered back on.

  • DEFERRED  On model 575 and 59x systems in which an IBM High Performance Switch (HPS) is installed, fixed a problem that was causing an invalid high performance switch adapter failure to be reported after a switch failure. 
  • DEFERRED  On model SR110000 systems only, fixed a problem that was causing the I/O in the CEC not to show up after an IPL. 
  • DEFERRED  On systems that are managed by an HMC, a problem was fixed that was causing concurrent firmware update to fail with error code ACT01724 on the HMC. 
  • DEFERRED  Fixed a problem involving correctable and uncorrectable memory errors that may have resulted in memory being deconfigured during a slow mode IPL on 9119-59x systems with F/C 7814 (4 GB memory cards) installed. 
  • Support for 16-way model 575 systems was added to the 01SF230 release. 
  • Fixed a problem that was causing the firmware to erroneously report a failure of the High Performance Switch (HPS) adapter card (with error code B181F62A) in a 16-way model 575 system. 
  • On model 59x systems, a memory leak was fixed that could cause the system to reset during boot.
  • Fixed false error code B1812033 introduced in code level 01SF230_120_120 on all p5 and i5 systems model 570 and lower. The B1812033 error code may still be valid on 575 and 59x systems. 
  • Fixed intermittent boot problem introduced in code level 01SF230_120_120 on all p5 and i5 systems model 550 and lower. Error codes related to this boot problem include B1701004, B181F12E or B150F22A. 
  • On model 575 and 59x systems in which an IBM High Performance Switch (HPS) is installed, a problem in the system firmware was fixed that was causing duplicate errors for the same problem to be reported in the service processor error log and the HPS Network Manager error log. 
  • On model 575 and 59x systems in which an IBM High Performance Switch (HPS) is installed, a problem in the system firmware was fixed that was causing some switch network interface (SNI) adapters to fail a wrap test. 
  • On systems that are managed by an HMC, fixed a problem that was preventing some types of errors that were logged in the service processor's error log from being sent to the HMC. 
  • Fixed a problem that caused a very early reset/reload of the service processor with error codes of B1817201, B1817209 or similar after a firmware update. 
  • On systems that shipped with a firmware level that begins with 01SF210, fixed a problem that was causing the firmware installation to the T side to fail with error code B1817201. 
  • Fixed a problem that was causing platform system dumps to be corrupted. 
  • Fixed a problem that was causing concurrent firmware maintenance to fail.
01SF230_126_120 Impact:  Function        Severity:  Hiper
  • Fixed a problem that causes the media bay to lose power, which makes the DVD drives in the bay inoperable on 9117-570 and 9406-570 systems.
  • Fixed most problems introduced in 01SF230_120_120 that causes the white power on/off button to intermittently fail to boot the system, terminating with error codes B181F12E, B1701004 or B150F22A, on 9111-520, 9113-550, 9405-520, 9406-520 and 9406-550 systems.
  • Fixed a problem that causes various types of planar and RIO cable failures in the 7040-61D I/O subsystem to be reported on 9118-575, 9119-590, 9119-595 and 9406-595.
01SF230_120_120 Impact:  Function        Severity:  Hiper

New function:

  • Adds code to notify the user when the VPD card is not in its original system, and to prevent that system from booting. 
  • Adds support for i5/OS hosting virtual Linux and AIX partitions on i5 systems that are not managed by an HMC. 
  • Adds support for F/C 7910 on model 9118-575 systems the switch network interface  adapter, which provides the interface to the pSeries high performance switch (HPS). 
  • Adds support for F/C 7817 on 9119-590, 9119-595, and 9406-595 systems, the switch network interface (SNI) adapter, which provides the interface to the pSeries high performance switch (HPS). 
  • Adds support for concurrent firmware maintenance on systems managed by an HMC. 
  • Adds support for 32GB memory cards on 9119-590, 9119-595, and 9406-595 systems. 
  • Adds support for F/C 7894, 8GB (4x2GB) feature (2GB DDR2 DIMMs, CCIN 30F3) on machine type 9117-570.
Problems resolved:
  • LEDs on GX bus adapter cards remain on after the node is powered off for 9119-590, 9119-595, and 9406-595 systems. 
  • The service processor is not able to place a "call home" through a modem. 
  • On systems 9118-575, 9119-590, 9119-595, and 9406-595: a firmware upgrade from SF222_075 to SF225_096 fails with error code ACT01724 on the HMC. 
  • Fixed a problem that causes the default boot list and the stored boot list to be swapped in the system management services (SMS) code when booting an AIX or Linux partition. 
  • Fixed a highly intermittent problem that causes the service processor to perform a dump when an SRC is displayed on the control panel. 
  • On  9118-575, 9119-590, 9119-595, and 9406-595 systems, updates the firmware so that the system will continue to boot when certain types of failures occur on bus adapter cards. 
  • Fixed a problem on  9118-575, 9119-590, 9119-595, and 9406-595 systems which caused a reboot to fail with error code B7006900 under certain conditions. 
  • Fixed a problem with moving a CD-ROM device between two logical partitions using DLPAR commands on the HMC. 
  • On 9117-570 and 9406-570 systems:  Fixed a problem a that causes a DMA_ERR with error code 1000 0003 on the integrated Ethernet port. 
  • DS8000 storage subsystem:  multiple firmware fixes. 
  • Fixed a problem that causes the system clock to revert to December 31, 1969 and the system to crash with error code B7000103. 
  • On 9119-590 systems, fixed a problem that keeps large configurations (12 or more I/O drawers with both planars installed) from booting. 
  • Fixed a problem that prevents the 'lscfg -vp' command from reporting platform-specific data on all p5 systems.
  • Fixed a problem that intermittently causes a partition or the system to hang when the lsvpd or lscfg command is run on all p5 systems.  Also, 'the lsmcode' command may return "NOT DETERMINABLE".
  • If two power supplies are installed, the system may fail to power on if one power supply fails in the 9110-510, 9111-520, 9113-550, 9117-570, 9123-xxx, 9124-xxx, 9405-520, 9406-520, 9406-550, 9406-570 systems.
  • Fixed a problem that prevents a virtual SCSI client from connecting to a virtual SCSI server adapter on 9118-575, 9119-590, and 9119-595 systems.

  •  


4.0 How to Determine Currently Installed Firmware Levels

Instructions for determining the current level of firmware can be found at http://publib.boulder.ibm.com/eserver/v1r3s/index.jsp?topic=/ipha5/viewexistlevel.htm


5.0 Downloading the Firmware Package

The firmware is located at the web site download.html

Follow the instructions on this web page. You must read and agree to the license agreement to obtain the firmware packages.

In the table for System Microcode, scroll down to the entry for 9110-510, etc.

You may download the individual .rpm and .xml files for system firmware from this location to your server, an ftp server, or a CD-ROM (both files are required).  Make sure the file names have the format 01SF2xx_yyy_zzz, with an extension of .rpm and .xml before copying them to your server, an ftp server or CD-ROM.  If using a CD-ROM, copy the .rpm and .xml files to the CD-ROM using a local CD-ROM burner utility. For  9119-590/595, 9406-595, or 9118-575 systems, your server, the ftp server or CD-ROM  must contain both the system firmware and power subsystem firmware files. You can obtain the .rpm and .xml files for the power subsystem by accessing this site other.html.

Another method is to download the ISO image  p5 and i5 iso and create a CD-ROM to use with your HMC. The CD-ROM contains both the system and power subsystem firmware files.

Note: If your HMC is not internet-connected you will need to download the new firmware level to a CD-ROM or ftp server.


6.0 Installing the Firmware

The method used to install new firmware will depend on the release level of firmware which is currently installed on your server. The release level can be determined by the prefix of the new firmware's filename.

Example: 01SFXXX_YYY_ZZZ

Where XXX =  release level

Instructions for installing firmware updates and upgrades can be found at
http://publib.boulder.ibm.com/infocenter/eserver/v1r3s/index.jsp?topic=/ipha5/fix_serv_firm_kick.htm

Choose the options that match your server setup, and follow the instructions provided.

Note: For systems without an HMC, the update and upgrade procedure is the same.
 


7.0 Firmware History

 
 
01SF225
01SF225_096_096 Impact:  Function   Severity:  Hiper
  • Fixed a problem in the service processor firmware that made it look like the T-side image was being lost after a "reset to factory configuration" was done using the ASMI menus. 
01SF225_080_080 Impact:  New        Severity:  New
  • Added support for 9118-575, 9110-510, and 9123-710.
 
01SF222
01SF222_081_081 Impact:  Function   Severity:  Hiper
  • Fixed a problem that caused FSCSI errors to show up erroneously in the AIX error log when an I/O adapter failed.
  • Fixed a problem that caused the processor runtime diagnostics to call out the wrong DIMM (or other memory component) when a memory failure occurred.
  • Fixed a problem that caused a platform dump to run out of storage space.
  • Fixed a problem that prevented the LEDs on I/O drawers from identifying or "rolling up" to the frame enclosure LED.
  • Fixed a problem that caused the service processor to generate error log entries every few seconds when attempting to service a recoverable CEC hardware error on systems that have processors with no memory associated with them.
01SF222_075_075 Impact:  Function   Severity:  Hiper
  • Fixed a problem with the AMSI menu option that allows system VPD keywords to be set.
  • Fixed a problem that kept the system from continuing to boot when an 8GB memory DIMM is deallocated because an uncorrectable error was generated by the DIMM during boot.
  • Fixed a problem that caused a partition's time to appear to drift (approximately 15 seconds/month) following a system IPL.
  • Support for partitions running i5/OS on p5 systems was added.
  • Fixed a problem that caused the default boot list and the stored boot list in the SMS menus to be swapped.
01SF222_071_071 Impact:  New        Severity:  New
  • Added support for systems 9119-590, 9119-595, and 9406-595.
 
01SF220
01SF220_051_051 Impact:  Function   Severity:  Hiper
  • Fixed a problem that kept feature code 1827, a UPS sense cable, from being detected. 
01SF220_049_049 Impact:  Function   Severity:  Hiper
  • Fixed a problem that kept the serial ports on the processor drawer from functioning in 9117-570 and 9406-570 systems with multiple processor drawers.
  • Fixed a problem that kept the user from accessing the advanced system management interface (ASMI) via the web interface.
01SF220_046_046 Impact:  Function   Severity:  Hiper
  • Fixed a problem that caused the kept the service processor from getting to standby when an Ethernet cable was not plugged into it.
01SF220_045_045 Impact:  Function   Severity: Hiper
  • Various corrections and updates.
01SF220_043_043 Impact:  New        Severity:  New 
  • Added support for new models:  9111-520, 9113-550, 9406-550, 9124-720, and 9117-570.