TITLE : Running the Diagnostic Programs from Diskettes OS LEVEL : AIX DATE : 19/03/99 VERSION : 1.0 ---------------------------------------------------------------------------- Consider the following when you run the diagnostic programs from diskettes: The diagnostic diskettes are labelled as to the devices and functions the diskettes contain. The following diskettes must be inserted in the order shown before the DIAGNOSTIC OPERATING INSTRUCTIONS will be displayed. 1. Boot diskette 2. Configuration diskette 3. Graphics diskette (optional if the system does not contain a graphics adapter) 4. Console Definition diskette. There are two different Boot diskettes, one for use in systems containing only 8MB of memory and one for use in systems containing a minimum of 16MB of memory. Only one diskette can be loaded. There are several different graphics diskettes for configuring and testing graphics adapters. Use only the graphics diskettes for the type of graphics adapters installed in the system. For each type of graphics adapter installed in a system, you must load the graphics diskette which supports that adapter in order to test it. The diskette containing the graphics adapter that will be used as the console for running diagnostics should be loaded first. If there are other graphics adapter types installed in the system, load the diskette supporting those adapters immediately following the first graphics diskette. If a device installed in a system is not supported by one of the diskettes shipped with the system, check for the existence of a supplemental diagnostic diskette shipped with the device. After the DIAGNOSTIC OPERATING INSTRUCTIONS are displayed, follow the displayed instructions in order to test the device or to run a Service Aid. The diagnostic programs shipped on diskettes with the system unit have a version number on the label. This Common Diagnostics and Service Guide also has a version number on the cover which should match the first two version number digits of the diskettes in order for diagnostics to work correctly. You can check the version of the diagnostic programs on the Diagnostic Operating Instructions. When you load the diagnostic programs from diskettes, you may get the following messages on the three-digit display or on the console display: c01 Insert the first diagnostic diskette c02 Diskettes inserted out of sequence c03 The wrong diskette is in the diskette drive c05 A diskette error occurred c07 Insert the next diagnostic diskette c09 Diskette is being read or written c31 Select the console display.