H166305: SYSTEM CLOCK (TIME) IS AFFECTED AFTER BOOTING FROM CD TEXT: System clock (time) is affected after booting from CD SYMPTOMS: The system's time has been changed back one (1) hour. PROBLEM ISOLATION AIDS: - The system is any of the following IBM Netfinity servers: a Netfinity 7000-M10 server, Type 8680, any Model. a Netfinity 7000 server, Type 8651, any Model. a Netfinity 5500-M20 server, Type 8662, any Model. a Netfinity 5500-M10 server, Type 8661, any Model. a Netfinity 5500 server, Type 8660, any Model. a Netfinity 5000 server, Type 8659, any Model. a Netfinity 3500 server, Type 8644, any Model. a Netfinity 3000 server, Type 8476, any Model. - The system has been booted from one or more of the following: ServerGuide Hardware CD, versions previous to 4.1 ServeRAID Configuration CD, versions previous to 3.50.04 - The system's time has been changed back one (1) hour, after being previously set correctly. FIX: - Use ServerGuide Hardware CD, version 4.1 or later - Use ServeRAID Configuration CD, version 3.50.04 or later. WORKAROUND: Be certain to check the system clock for the correct time after booting from the ServeRAID Configuration CD ROM or the Server Guide (Hardware Guide) CD-ROM. DETAILS: When the ServeRAID Configuration (Version lower than 3.50.04) CD-ROM or the Server Guide (Version lower than 3.50.04) CD-ROM Graphical user Interface boots, the system clock can be set back one hour. DATE: April 14, 1999