H164030: ECA014: NETFINITY 7000 POWER CORD/RECEPTACLE COMPATIBILITY PURPOSE: This ECA provides for the removal of a 220 Volt/16 Amp AC Power Assembly, 220 Volt/16 Amp Line Cord, and the installation of a 220 Volt/10 Amp AC Power Assembly and country specific 220 Volt/10 Amp Line Cord on the IBM Netfinity 7000 type 8651 model TH0/TM0 to allow for supplying AC power to the server using the more common 220 Volt/10 Amp wall receptacle specific to some countries. One (1) 220 Volt/10 Amp AC Power Assembly, one (1) 220 Volt/10 Amp Line Cord, and Instruction Sheet are contained in the following FBM Kits respective to the countries that this ECA applies to: Country FBM Kit China ------------------------------------------------ 03K9151 Australia / New Zealand / Papua New Guinea / Argentina 03K9152 Italy / Chile / Ethiopia / Libya / Somalia ----------- 03K9153 Denmark ---------------------------------------------- 03K9154 Switzerland / Liechtenstein -------------------------- 03K9155 Refer to the Instruction Sheet contained in the FBM Kit for replacement of the AC Power Assembly in the Server or refer to the Hardware Maintenance Manual (p/n06J0791) for the Netfinity 7000. FEATURES: Type, Machines Affected Model, With and/or Feature/Device B/M to be Service System Stage B/M Description Installed Hours Hours 8651 B/M0000000 NETFINITY 7000 TYPE B/M0000000 00.7 00.5 8651 MODEL TH0/TM0 LOCATED IN THE ECA014 SPECIFIED COUNTRIES THAT MAY REQUIRE 10AMP AC POWER CONNECTION. PHYSICAL CHECK: - This ECA applies to servers located in or will be located in one of the following countries only: China / Australia / New Zealand / Argentina / Papua New Guinea / Italy / Chile / Ethiopia / Libya / Somalia / Denmark / Switzerland / Liechtenstein - The customer requires that the Server is powered with a standard 220 Volt/10 amp Line Cord typical to the country. - The Server has the Ship-level 220 Volt/16 Amp Power Assembly (the 220 Volt/16 Amp Power Assembly has a 220 Volt/16 Amp AC power connector located at the back). - The Server is NOT in a IBM Server Rack. PREREQUISITES: NONE COMPANION: NONE CONCURRENT: NONE DETAIL: This ECA replaces the Server's 220 Volt/16 Amp Power Assembly (FRU p/n12J3264) with a 220 Volt/10 Amp AC Power Assembly (FRU p/n03K8966) to allow use of the more common 220 Volt/10 Amp Power Cord specific to the counties specified in this ECA that may only have a 220 Volt/10 Amp wall receptacle. 1- Have the Local Administrator Down the Network Operating system. 2- Power down the Server. Note: Refer to the Instruction Sheet that was packed in the FBM Kit or, Refer to the Hardware Maintenance Manual for the Netfinity 7000; the "AC Power Assembly" section describes the following steps in detail: 3- Remove the Hot-Swap Power Supplies. 4- Remove the 5-Volt Regulator Card. 5- Remove the 16 Amp AC Power Assembly. 6- Install the 10 Amp AC Power Assembly. 7- Install the 5-Volt Regulator Card. 8- Install the Hot-Swap Power Supplies. 9- Power on the Server, check the Server's Power Supply Status Indicators to be sure that all the Hot-Swap Power supplies are operating correctly (refer to the Hardware Maintenance Manual for the Netfinity 7000, see the "Status Indicators" section). NOTES: THIS ECA IS "AS REQUIRED". ONLY IBM AUTHORIZED SERVICERS MAY APPLY THIS ECA. THIS ECA WILL EXPIRE 10/13/2004 **************************************************************** **************************************************************** FOR NORMAL SERVICE ACTIVITY IN THE COUNTRIES SPECIFIC TO THIS ECA USE THE FOLLOWING FRU P/N'S: - 10 Amp Power Assembly (FRU p/n03K8966) - 16 Amp Power Assembly (FRU p/n12J3264) - Power Cords: Country 10 Amp 16 Amp China ------------------------------------------ 02K0546 01K9851 Australia/New Zealand/Papua New Quinea/Argentina 13F9940 12J5128 Italy/Chile/Ethiopia/Libya/Somalia ------------- 14F0069 12J6126 Denmark ---------------------------------------- 13F9997 55H6646 Switzerland/Liechtenstein ---------------------- 14F0051 55H6646 NOTE: 10 Amp Power Assembly requires 10 Amp Power Cord, 16 Amp Power Assembly requires 16 Amp Power Cord. **************************************************************** **************************************************************** WHEN IMPLEMENTING THIS ECA: Country Specific FBM kits must be ordered using Code B and reference ECA014 (Any orders for the FBM kits under normal FBM replacement parts will be rejected). Discard the 16 AMP Power Assembly and 16 Amp Cord. USA: This ECA does not apply to any servers in the USA or any other country in North America, due to the Electrical Standards used. EMEA: PSS: CE's should record all time and parts to Service Code 33, (8651) ECA014, Other Office 990. BUSINESS PARTNERS: Refer to Warranty Claim System; Use Emergency Warranty Claim type 5 (ECA), quoting CPPS ECA Code: M/T 8651 = "SE" DATED: September 14, 1998