Record number H135609 Device: D/T3547 Service code: 33 ECA number: ECA001 Parts source: LOC EC number: ECE67327 Publish flag: R Mandatory: N Hit count: UHC00000 Automatic shipment: N Success count: USC0000 Availability date: 96/12 Publication code: PC40 Plant of control: 23 Date created: O96/12/06 Tip key: Date last altered: A96/12/06 Owning B.U.: Abstract: 3547 SELECTA DOCK I WITH 760E OR ED HANGS AT POST. PURPOSE: Eliminate 760ED and 760ED system lockup during POST while connected to a 3547 SlectaDock I. FEATURES: Type, Machines Affected Model, With and/or Feature/Device B/M to be Service System Stage B/M Description Installed Hours Hours 3547 B/M9999999 9546 MOD U3A, U9A, U9B B/M9999999 00.7 00.5 PHYSICAL CHECK: All of the following conditions must be present to qualify ECA usage. o ThinkPad 760E and 760ED models referenced in the FEATURES section. o Intermittent hangs during POST. o ThinkPad installed in a 3547 "SlectaDock I" with a serial number below 97-34259. Note: "SlectaDock I" docking stations with a serial number of 97-34259 or higher contain the new system board and will not require this ECA. PREREQUISITES: NONE COMPANION: NONE CONCURRENT: NONE DETAIL: 9546 760E and 760ED models referenced in the FEATURES section of this ECA may intermittently lockup during POST if they are installed in the 3547 SlectaDock I. The lockup condition occurs during POST Check Point 40, the screen is blank except for a cursor in the upper left corner. The type of operating system is not a factor, because the failure occurs before it is loaded. A new "SelectaDock I" system board has been released to correct this condition. The new system board is FRU P/N39H7452. If the old FRU, P/N39H7422, is ordered it will automatically substitute to the new FRU number. NOTE: SlectaDocks used with the following models do not require this ECA. ============================================================== | UNAFFECTED MODELS | |o All 760EL and 760ELD models. | |o 760E models U3B, U4A, U4B, and U3L. | | | | | ============================================================== NOTES: This ECA will expire November 1, 1997. Order FRU P/N39H7452 and record all time using Service Code 33, ECA001, other office 990. SAS KEYWORDS: PSY2 PSY2ECA THINKPAD PSY2BRD HANG UNCLASSIFIED ****** HSF PRINT RECORD REQUEST COMPLETE 12/06/96 HUBER, GARY F *****