H001481 - SERVER 320/520 SERVERGUIDE INSTALLATION FAILS OR HANGS SYMPTOM: PCI/MicroChannel versions of the IBM PC Server 320 and 520, with a PCI or MicroChannel RAID Adapter, fail to install NetWare, Windows NT, or SCO from ServerGuide Version 2.5. - The NetWare 3.12 and 4.1 installations display the following even after inserting the NetWare CD: "INSERT THE NETWARE CD INTO THE CD-ROM DRIVE AND WAIT FOR BAD COMMAND OR FILENAME PRESS ANY KEY TO CONTINUE..." --OR-- - The SCO V3.0 installation displays the following: "F33 WARNING: no root disk controller H6 PANIC: srmountfun-error 19 mounting rootdev(1/40) Trying to dump 8095 pages to DUMPDEV RAM (31/8) at block 32 4 pages dumped NOTICE: FLUSHING DAC 960P 0 CACHE ...DONE SAFE to POWER OFF or Press ANY KEY to REBOOT" --OR-- - The Windows NT Server 3.51 installation displays the following: "STOP: C00012F The specified image file did not have the Correct Format It did not have an Initial MZ. Restart and set the Recovery options in the system control panel or the crash debug system start option. If this message reappears, contact your system administrator or Technical Support Group." PROBLEM ISOLATION AIDS: NONE FIX: A permanent fix is being developed and will be included in the next release of ServerGuide. As a workaround, use the following procedure: (Works for NetWare, SCO, and Windows NT) 1. Power off the server and open or remove the system cover. 2. Move Jumper J26 to the "ADAPTER" position (jumper pins 2-3). Refer to the system board schematic located on the server. 3. Close up the server, insert the ServerGuide license diskette into drive A:, insert the ServerGuide V2.5 Main CD into the CD-ROM, power on the server, and complete the installation. 4. When the installation is complete, shutdown the operating system, power off the server, and move Jumper J26 back to the "PLANAR" position (jumper pins 1-2). --OR-- For NetWare installations only, do the following: 1. After the NetWare installation fails, insert the ServerGuide license diskette into drive A:, insert the ServerGuide Main CD into the CD-ROM, reboot the server, select the appropriate NetWare versions and proceed to the Configuring NetWare screen. Note that the default disk controller is: SCSI-2 PCI 2. Change this selection to the controller connected to both the RAID drives and the CD-ROM (ie. SCSI-2 Fast/Wide PCI-Bus RAID adapter). 3. Continue the installation normally. NetWare, SCO Unix, and Windows NT default to installing to the SCSI controller integrated on the planar when Jumper J26 is set to the "PLANAR" setting. By disabling the integrated SCSI controller, ServerGuide installs using the controller that has the hard drives and CD-ROM attached to it. NetWare is a trademark of Novell Inc. SCO is a trademark of The Santa Cruz Operation Inc. Windows NT is a trademark of Microsoft Corp.