| Error Code/Symptom: |
|
| 101, 102 |
1. System Board |
| (System and microprocessor error) |
|
| 0103 |
1. System Board |
| (System Timer error) |
|
| 106 |
1. System Board |
| (System and microprocessor error) |
|
| 0110 |
1. Memory SIMM |
| (Parity Check 1 XXXX, run Setup) |
2. System Board |
| 111 |
1. Memory SIMM |
| (I/O channel check error) |
2. System Board |
| 114 |
1. Run Diagnostics |
| (Adapter read-only memory error) |
2. Failing Adapter |
| 0115 |
1. Memory SIMM |
| (Parity Check 1 XXXX, run Setup) |
2. System Board |
| 0120 |
1. Run Setup |
| (Previous boot incomplete, |
2. Battery/CMOS Chip |
| default configuration used) |
3. System Board |
| 0130 |
1. Battery/CMOS Chip |
| (Invalid NVRAM media type) |
1. System Board |
| 151 |
1. Run Diagnostics |
| (Real time clock error) |
2. System Board |
| 161 |
1. Battery |
| (Real time clock battery error) |
|
| 0162 (Models EXX) |
1. Battery/CMOS Chip |
| (Configuration error for |
2. System Board |
| slot XX, run Setup, then, run |
|
| the EISA Configuration Utility) |
|
| 162 (Type 8641 Models MXX) |
1. Run Configuration/Setup |
| (Configuration error) |
|
| 0163 (Models EXX) |
1. Battery/CMOS Chip |
| (Real-Time Clock error) |
2. System Board |
| 163 (Type 8641 Models MXX) |
1. Run Configuration, set time and date |
| (Time of day not set) |
|
| 164 |
1. Run Configuration |
| (Memory configuration changed) |
|
| 165 |
1. Run Configuration, |
| (Micro Channel adapter |
2. insert Reference diskette |
| configuration changed) |
|
| 0171 |
1. Battery/CMOS Chip |
| (System battery is dead) |
2. System Board |
| 0173 |
1. Run Setup |
| (System CMOS checksum bad) |
2. Battery/CMOS Chip |
| |
3. System Board |
| 0174 |
1. Run Setup |
| (Invalid ISA Configuration) |
2. Look for configuration conflicts. |
| |
3. Battery/CMOS Chip |
| 0175 (Models EXX) |
1. Run Setup |
| (EISA Configuration Error, |
2. Run EISA Configuration Utility |
| run the configuration utility) |
3. Battery/CMOS Chip |
| |
4. System Board |
| 175 (Type 8641 Models MXX) |
1. Run Diagnostics |
| (Hardware error) |
2. System Board |
| 176 |
1. Run Configuration/Setup |
| (Computer cover or cable cover |
|
| was removed without a key being |
|
| used) |
|
| 177, 178 |
1. Run Diagnostics |
| (Hardware error) |
2. System Board |
| 184 |
1. Run Configuration/Setup |
| (Power-on password corrupted) |
|
| 185 |
1. Run Configuration/Setup |
| (Drive startup sequence |
|
| information corrupted) |
|
| 186 |
1. Run Configuration/Setup |
| (System board or security |
2. System Board |
| hardware error) |
|
| 189 |
1. Run Configuration, |
| (An attempt was made to access |
enter the administrator password |
| the computer with an |
|
| invalid password) |
|
| 201 |
1. Memory SIMM |
| (Memory test error) |
2. System Board |
| 0214 |
1. Memory SIMM |
| (System RAM failed |
2. System Board |
| at offset XXXX) |
|
| 0215 |
1. Memory SIMM |
| (Failing Bits XXXX) |
2. System Board |
| 0216 |
1. Memory SIMM |
| (Extended RAM failed |
2. System Board |
| at offset XXXX) |
|
| 0221 |
1. Memory SIMM |
| (Shadow RAM failed at offset) |
2. System Board |
| 0254 |
1. System Board Cache |
| (System board Cache error, |
2. System Board |
| Cache disabled) |
|
| 229 |
1. Cache memory |
| (Cache memory test error. |
2. System Board |
| Be sure the cache memory_pd. |
|
| is enabled.) |
|
| 0301 |
1. Keyboard |
| (Keyboard or keyboard |
2. System Board |
| controller error) |
|
| 0302 |
1. Unlock the keyboard |
| (Keyboard locked) |
2. Keyboard |
| |
3. System Board |
| 0303 |
1. Keyboard |
| (Keyboard Error, stuck key) |
2. System Board |
| 604 |
1. Diskette Drive |
| (Diskette drive error) |
2. Drive Cable |
| |
3. System Board |
| 0610 |
1. Run Setup |
| (Incorrect drive A type) |
2. Diskette Drive |
| |
3. System Board |
| |
4. Diskette Drive Cable |
| 0612 |
1. Run Setup |
| (Incorrect drive B type) |
2. Diskette Drive |
| |
3. System Board |
| |
4. Diskette Drive Cable |
| 0632 |
1. Run Setup |
| (Diskette drive A error) |
2. Diskette Drive |
| |
3. System Board |
| |
4. Diskette Drive Cable |
| 0642 |
1. Run Setup |
| (Diskette drive B error) |
2. Diskette Drive |
| |
3. System Board |
| |
4. Diskette Drive Cable |
| 662 |
1. Run Configuration/Setup |
| (Diskette drive |
|
| configuration error) |
|
| 762 |
1. Run Configuration/Setup |
| (Processor configuration error) |
2. Run Diagnostics |
| 962 |
1. Disconnect external cable on |
| (Parallel port error) |
parallel port. |
| |
2. Internal Cable |
| |
3. System Board |
| 1162 |
1. Disconnect ext. cable on serial port. |
| (System-board serial port |
2. Run Configuration |
| 1 or 2 error) |
|
| 1300 |
1. Run Setup with known good diskette |
| (Operating system not found) |
2. Fixed Disk Drive |
| |
3. Fixed Disk Adapter |
| |
4. Diskette Drive |
| |
5. System Board |
| 1701 |
1. Run Setup |
| (Fixed Disk X failed) |
2. Fixed Disk Drive |
| |
3. Fixed Disk Adapter |
| |
4. System Board |
| 1702 |
1. Run Setup |
| (Fixed Disk Drive |
2. Fixed Disk Adapter |
| Controller failed) |
3. Fixed Disk Drive |
| |
4. System Board |
| 1801 |
1. Run Reference Diskette |
| (No room for PCI option ROM) |
2. Failing Adapter |
| |
3. System Board |
| 1802 |
1. Run Reference Diskette |
| (No more I/O space avail. |
2. Failing Card |
| for PCI adapter) |
3. System Board |
| 1803 |
1. Run Reference Diskette |
| (No more memory |
2. Failing Card |
| (above 1MB for PCI adapter) |
3. System Board |
| 1804 |
1. Run Reference Diskette |
| (No more memory |
2. Failing Card |
| (below 1MB for PCI adapter) |
3. System Board |
| 1805 |
1. Remove Failing PCI Card |
| (PCI option ROM |
2. System Board |
| checksum error) |
|
| 1962 |
1. Run Configuration/Setup |
| (No valid boot device found, |
2. Run Diagnostics |
| be sure the drive you want |
3. Drive Cable |
| to start from is |
4. Hard Disk Drive |
| the boot sequence) |
5. System Board |
| 2401 |
1. Run Setup and enter correct monitor type |
| (Monitor type does not match CMOS) |
2. Video Display |
| |
3. Video Adapter |
| |
4. System Board |
| 2462 |
1. Display |
| (Video controller error) |
2. System Board |
| 000247100 (Type 8641) |
1. N/A |
| L2 processor cache was |
|
| disabled, do the following: |
|
| Boot the system diagnostics. |
|
| Run the processor tests. |
|
| When asked if you want to |
|
| turn on the processor cache, |
|
| reply, "yes," and the |
|
| error will be cleared. |
|
| I9990301 |
1. Install operating system |
| (Fixed boot sector error, |
2. to hard disk drive. |
| no operating system installed) |
|
| 8601, 8603 |
1. Pointing Device |
| (Pointing Device Error) |
2. System Board |