Error Code/Symptom:  
101, 102 1. System Board
   (System and microprocessor error)  
0103 1. System Board
   (System Timer error)  
106 1. System Board
   (System and microprocessor error)  
0110 1. Memory SIMM
   (Parity Check 1 XXXX, run Setup) 2. System Board
111 1. Memory SIMM
   (I/O channel check error) 2. System Board
114 1. Run Diagnostics
   (Adapter read-only memory error) 2. Failing Adapter
0115 1. Memory SIMM
   (Parity Check 1 XXXX, run Setup) 2. System Board
0120 1. Run Setup
   (Previous boot incomplete, 2. Battery/CMOS Chip
   default configuration used) 3. System Board
0130 1. Battery/CMOS Chip
   (Invalid NVRAM media type) 1. System Board
151 1. Run Diagnostics
   (Real time clock error) 2. System Board
161 1. Battery
   (Real time clock battery error)  
0162 (Models EXX) 1. Battery/CMOS Chip
   (Configuration error for 2. System Board
   slot XX, run Setup, then, run  
   the EISA Configuration Utility)  
162 (Type 8641 Models MXX) 1. Run Configuration/Setup
   (Configuration error)  
0163 (Models EXX) 1. Battery/CMOS Chip
   (Real-Time Clock error) 2. System Board
163 (Type 8641 Models MXX) 1. Run Configuration, set time and date
   (Time of day not set)  
164 1. Run Configuration
   (Memory configuration changed)  
165 1. Run Configuration,
   (Micro Channel adapter 2. insert Reference diskette
   configuration changed)  
0171 1. Battery/CMOS Chip
   (System battery is dead) 2. System Board
0173 1. Run Setup
   (System CMOS checksum bad) 2. Battery/CMOS Chip
  3. System Board
0174 1. Run Setup
   (Invalid ISA Configuration) 2. Look for configuration conflicts.
  3. Battery/CMOS Chip
0175 (Models EXX) 1. Run Setup
   (EISA Configuration Error, 2. Run EISA Configuration Utility
   run the configuration utility) 3. Battery/CMOS Chip
  4. System Board
175 (Type 8641 Models MXX) 1. Run Diagnostics
   (Hardware error) 2. System Board
176 1. Run Configuration/Setup
   (Computer cover or cable cover  
   was removed without a key being  
   used)  
177, 178 1. Run Diagnostics
   (Hardware error) 2. System Board
184 1. Run Configuration/Setup
   (Power-on password corrupted)  
185 1. Run Configuration/Setup
   (Drive startup sequence  
   information corrupted)  
186 1. Run Configuration/Setup
   (System board or security 2. System Board
   hardware error)  
189 1. Run Configuration,
   (An attempt was made to access     enter the administrator password
   the computer with an  
   invalid password)  
201 1. Memory SIMM
   (Memory test error) 2. System Board
0214 1. Memory SIMM
   (System RAM failed 2. System Board
   at offset XXXX)  
0215 1. Memory SIMM
   (Failing Bits XXXX) 2. System Board
0216 1. Memory SIMM
   (Extended RAM failed 2. System Board
   at offset XXXX)  
0221 1. Memory SIMM
   (Shadow RAM failed at offset) 2. System Board
0254 1. System Board Cache
   (System board Cache error, 2. System Board
   Cache disabled)  
229 1. Cache memory
   (Cache memory test error. 2. System Board
   Be sure the cache memory_pd.  
   is enabled.)  
0301 1. Keyboard
   (Keyboard or keyboard 2. System Board
   controller error)  
0302 1. Unlock the keyboard
   (Keyboard locked) 2. Keyboard
  3. System Board
0303 1. Keyboard
   (Keyboard Error, stuck key) 2. System Board
604 1. Diskette Drive
   (Diskette drive error) 2. Drive Cable
  3. System Board
0610 1. Run Setup
   (Incorrect drive A type) 2. Diskette Drive
  3. System Board
  4. Diskette Drive Cable
0612 1. Run Setup
   (Incorrect drive B type) 2. Diskette Drive
  3. System Board
  4. Diskette Drive Cable
0632 1. Run Setup
   (Diskette drive A error) 2. Diskette Drive
  3. System Board
  4. Diskette Drive Cable
0642 1. Run Setup
   (Diskette drive B error) 2. Diskette Drive
  3. System Board
  4. Diskette Drive Cable
662 1. Run Configuration/Setup
   (Diskette drive  
   configuration error)  
762 1. Run Configuration/Setup
   (Processor configuration error) 2. Run Diagnostics
962 1. Disconnect external cable on
   (Parallel port error)     parallel port.
  2. Internal Cable
  3. System Board
1162 1. Disconnect ext. cable on serial port.
   (System-board serial port 2. Run Configuration
   1 or 2 error)  
1300 1. Run Setup with known good diskette
   (Operating system not found) 2. Fixed Disk Drive
  3. Fixed Disk Adapter
  4. Diskette Drive
  5. System Board
1701 1. Run Setup
   (Fixed Disk X failed) 2. Fixed Disk Drive
  3. Fixed Disk Adapter
  4. System Board
1702 1. Run Setup
   (Fixed Disk Drive 2. Fixed Disk Adapter
   Controller failed) 3. Fixed Disk Drive
  4. System Board
1801 1. Run Reference Diskette
   (No room for PCI option ROM) 2. Failing Adapter
  3. System Board
1802 1. Run Reference Diskette
   (No more I/O space avail. 2. Failing Card
   for PCI adapter) 3. System Board
1803 1. Run Reference Diskette
   (No more memory 2. Failing Card
   (above 1MB for PCI adapter) 3. System Board
1804 1. Run Reference Diskette
   (No more memory 2. Failing Card
   (below 1MB for PCI adapter) 3. System Board
1805 1. Remove Failing PCI Card
   (PCI option ROM 2. System Board
   checksum error)  
1962 1. Run Configuration/Setup
   (No valid boot device found, 2. Run Diagnostics
   be sure the drive you want 3. Drive Cable
   to start from is 4. Hard Disk Drive
   the boot sequence) 5. System Board
2401 1. Run Setup and enter correct monitor type
   (Monitor type does not match CMOS) 2. Video Display
  3. Video Adapter
  4. System Board
2462 1. Display
   (Video controller error) 2. System Board
   000247100 (Type 8641) 1. N/A
   L2 processor cache was  
   disabled, do the following:  
   Boot the system diagnostics.  
   Run the processor tests.  
   When asked if you want to  
   turn on the processor cache,  
   reply, "yes," and the  
   error will be cleared.  
I9990301 1. Install operating system
   (Fixed boot sector error, 2. to hard disk drive.
   no operating system installed)  
8601, 8603 1. Pointing Device
   (Pointing Device Error) 2. System Board


Please see the LEGAL  -  Trademark notice.
Feel free - send a Email-NOTE  for any BUG on this page found - Thank you.