Miscellaneous Symptoms (3550)



Miscellaneous Symptoms
Symptom/Error    FRU/Action
   Program-load error during 1. Network Adapter
   remote IPL from the file  
   service. Displayed on upper  
   or lower half of the LCD.  
   External display screen 1. External Display
   changes colors. 2. Docking Frame
   One or more keys do not 1. External Keyboard
   work on the external keyboard 2. Keyboard Cable
   but the 3550 Expansion Unit 3. System Board of 3550 Expansion Unit
   is otherwise functional.  
   (See  
   'Ext. Keyboard/Aux. Input Device Checkout'.)    
   Power-good light does 1. System Board of 3550 Expansion Unit
   not turn on and fan runs. 2. Power Supply
   Power-good light does 1. Power Supply
   not turn on, fan does not 2. System Board of 3550 Expansion Unit
   run, and 3550 Expansion  
   Unit is not functional.  
   (See 'Undetermined Problem'.)  
   Intermittent Failures. 1. Power Supply
   (See 'Undetermined Problem'.) 2. System Board of 3550 Expansion Unit
  3. Any Device or Adapter
   3550 Expansion Unit 1. System Board of 3550 Expansion Unit
   cannot be powered-off. 2. Power Supply
   LED for hard disk drive 1. SCSI Hard Disk Drive
   stays on. 2. System Board of 3550 Expansion Unit
   LED for hard disk drive 1. System Board of 3550 Expansion Unit
   is not working, but the  
   3550 Expansion Unit is  
   completely functional.  


Please see the LEGAL  -  Trademark notice.