| Symptom/Error |
FRU/Action |
| No access to A or C drive after POST. |
1. Ensure boot sequence is not set to 'Monitor' |
| CHECKSUM ERROR ! Bad image file. |
1. Advanced Diagnostics diskette |
| ERROR occurred while reading file. |
|
| Device error during erasing process. |
1. System Board |
| Device error during programming process. |
1. DC-to-DC board |
| |
2. System Board |
| DISK ERROR: Bad disk controller ! |
1. Check disk drive cable connection. |
| |
2. Diskette Drive Cable |
| DISK ERROR: Cannot reset drive ! |
1. Verify drive installation. |
| |
2. Diskette Drive |
| |
3. System Board |
| DISK ERROR: CRC error ! |
1. Diskette |
| |
2. Diskette Drive Cable |
| |
3. Run Advanced Diagnostics to test drive. |
| |
4. Diskette Drive |
| |
5. System Board |
| DISK ERROR: Data Corrected ! |
1. If this message occurs regularly, see |
| |
DISK ERROR: CRC error ! |
| DISK ERROR: Disk not bootable ! |
1. Use a bootable diskette. |
| |
2. For a hard disk, reinstall the operating system. |
| |
3. Back up the hard disk, if possible, and run PREP |
| |
to reinitialize the disk (see 'Running PREP'). |
| |
Reformat disk and install operating system. |
| |
4. Hard Disk Drive |
| DISK ERROR: DMA overrun ! |
1. Diskette Drive |
| |
2. System Board |
| DISK ERROR: Drive not ready ! |
1. Remove and reinsert diskette. |
| Verify the correct drive was specified. |
2. Diskette Drive |
| DISK ERROR: Invalid address mark ! |
1. If the problem is a diskette: |
| |
a. Copy any readable files to another diskette |
| |
and reformat faulty diskette. |
| |
If bad sectors are reported, discard the |
| |
faulty diskette. |
| |
b. Diskette |
| |
c. Diskette Drive |
| |
2. If the problem is a hard disk: |
| |
a. Back up the hard disk, if possible, and run PREP |
| |
to reinitialize the disk (see 'Running PREP'). |
| |
Reformat disk and install operating system. |
| |
b. Hard Disk Drive |
| DISK ERROR: Invalid data read ! |
1. If the problem is a diskette: |
| |
a. Copy any readable files to another diskette |
| |
and reformat faulty diskette. |
| |
If bad sectors are reported, discard the |
| |
faulty diskette. |
| |
b. Diskette |
| |
c. Diskette Drive |
| |
2. If the problem is a hard disk: |
| |
a. Back up the hard disk, if possible, and run PREP |
| |
to reinitialize the disk (see 'Running PREP'). |
| |
Reformat disk and install operating system. |
| |
b. Hard Disk Drive |
| DISK ERROR: Must run SETUP to boot |
1. Run Setup program to specify correct hard |
| from Winchester ! |
disk drive type. |
| |
2. System Board |
| DISK ERROR: No bootable partitions |
1. Retry the boot command syntax and verify a valid |
| |
partition is selected using the DOS 'FDISK' command. |
| |
2. Format partition and install operating system |
| |
using the DOS 'FORMAT' command. |
| DISK ERROR: Sector not found ! |
1. If the problem is a diskette: |
| |
a. Copy any readable files to another diskette |
| |
and reformat faulty diskette. |
| |
If bad sectors are reported, discard |
| |
the faulty diskette. |
| |
b. Diskette |
| |
c. Diskette Drive |
| |
2. If the problem is a hard disk: |
| |
a. Back up the hard disk, if possible, and run PREP |
| |
to reinitialize the disk (see 'Running PREP'). |
| |
Reformat disk and install operating system. |
| |
b. Hard Disk Drive |
| DISK ERROR: Seek failure ! |
1. Copy any readable files to another diskette |
| |
and format the faulty diskette. |
| |
2. If bad sectors are reported, discard the |
| |
faulty diskette. |
| |
3. Diskette |
| |
4. Diskette Drive |
| |
5. System Board |
| ERROR: Bad configuration |
1. Run Setup program to reconfigure. |
| information found in CMOS ! |
2. Backup Battery |
| |
3. System Board |
| ERROR: Base memory size error: |
1. Run Setup program to verify correct base memory size. |
| SETUP: XXXK |
2. Run the Advanced Diagnostics Memory Test to check base memory. |
| ACTUAL: XXXK ! |
3. System Board |
| ERROR: Can't locate input file. |
1. Correct Advanced Diagnostics diskette ? |
| |
2. Advanced Diagnostics diskette |
| ERROR: CMOS memory failure ! |
1. Run Setup program to verify configuration. |
| |
2. System Board |
| ERROR: CPU failure ! |
1. System Board |
| ERROR: Divide by zero ! |
1. Try another copy of the software, or have |
| |
the customer contact the software manufacturer |
| |
or dealer and report the problem. |
| |
Unless this message occurs during the power-up |
| |
sequence, the problem is with the software. |
| |
2. Power-off computer, wait 15 seconds, then |
| |
power-on computer. If the message reappears, |
| |
replace system board. |
| ERROR: Extended memory size |
1. Run Setup program to verify the extended RAM |
| error ! SETUP: XXXK ACTUAL: XXXXK |
memory size matches the memory installed. |
| |
2. Check the memory module installation. |
| |
3. Run Advanced Diagnostics to test extended memory. |
| |
If you cannot boot the computer, replace the |
| |
system board and try again. |
| |
If the tests identify an expansion memory module, |
| |
replace it. |
| |
If the tests identify a problem in the base memory, |
| |
replace the system board. |
| ERROR: File too long for program buffers. |
1. Correct Advanced Diagnostics diskette ? |
| |
2. Advanced Diagnostics diskette |
| ERROR: File too long for ROM size |
1. Correct Advanced Diagnostics diskette ? |
| |
2. Advanced Diagnostics diskette |
| ERROR: File too short to fill ROM. |
1. Correct Advanced Diagnostics diskette ? |
| |
2. Advanced Diagnostics diskette |
| ERROR: Invalid command ! |
1. Retry the command. |
| |
2. Try another copy of the software or have the |
| |
customer contact the software manufacturer |
| |
or dealer and report the problem. |
| |
3. System Board |
| ERROR: Keyboard not responding or |
1. Check keyboard connections. |
| not connected ! |
2. Keyboard |
| |
3. System Board |
| ERROR: Memory parity failure ! |
1. Run Advanced Diagnostics Memory Test to |
| |
check base and extended memory. |
| |
2. Memory Module |
| |
3. System Board |
| ERROR occurred while reading |
1. Advanced Diagnostics diskette |
| Boot Sector. |
|
| ERROR occurred while reading |
1. Advanced Diagnostics diskette |
| FAT table. |
|
| ERROR occurred while reading |
1. Advanced Diagnostics diskette |
| root directory. |
|
| ERROR: Please replace the |
1. If backup battery was recently replaced, run |
| backup battery |
Setup program to configure computer. |
| |
2. Backup Battery |
| |
3. System Board |
| Error programming FLASH Device. |
1. System Board |
| Retrying. |
|
| ERROR: RAM failure ! Address: XXXX |
1. Inspect memory modules for proper installation. |
| |
2. Swap the installed memory modules with known |
| |
good modules. |
| |
3. Memory Board |
| |
4. System Board |
| ERROR: RAM failure ! |
1. Inspect the memory modules for proper installation. |
| SIMM module: XXXX |
2. Swap the installed memory modules with known |
| |
good modules. |
| |
3. Memory Board |
| |
4. System Board |
| ERROR: ROM checksum failure ! |
1. Power-off computer, wait 15 seconds, then |
| |
power-on computer. If the message reappears, |
| |
replace system board. |
| ERROR: System control processor failure |
1. Power-off computer, wait 15 seconds, |
| |
then power-on computer. If message reappears, |
| |
replace system board. |
| ERROR: The image file is not for |
1. Correct Advanced Diagnostics diskette ? |
| this machine. |
2. Advanced Diagnostics diskette |
| ERROR: Timer interrupt failure ! |
1. Power-off computer, wait 15 seconds, |
| |
then power-on computer. |
| |
If message reappears, replace system board. |
| ERROR: Wild Hardware Interrupt. |
1. Power-off computer, wait 15 seconds, then |
| |
power-on computer. Rerun the program. |
| |
2. If message reoccurs at the same place during |
| |
operation of a program, it is probably software related. |
| |
Have the customer contact the software manufacturer |
| |
or dealer to report problem. |
| |
3. System Board |
| Fatal Error, Cannot Continue ! |
1. Refer to first error message and follow instructions |
| |
to resolve the problem. |
| File not found, try another diskette. |
1. Try another Advanced Diagnostics diskette. |
| FLASH Device failure ! |
1. System Board |
| Device content has been corrupted. |
|
| High ROM Checksum Error ! Flash ROM |
1. BIOS within the Flash ROM is corrupt. |
| needs to be reprogrammed |
The NEWBIOS command will automatically be executed. |
| |
See 'Updating Flash Memory'. |
| Low ROM Checksum Error ! Flash ROM |
1. See 'Updating Flash Memory' |
| needs to be reprogrammed. |
|
| Non-maskable interrupt received ! |
2. If a software problem is suspected, have the customer |
| |
contact the software manufacturer or dealer and report |
| |
the problem. |
| |
3. Run Advanced Diagnostics. |
| |
4. AC Adapter |
| No system |
1. Install the operating system. |
| |
Refer to the operating system documentation for instructions. |
| |
2. Retry the boot command syntax and verify a |
| |
valid drive was selected. |
| Not a bootable partition |
1. Retry the boot command syntax and make certain |
| |
a valid partition was selected. |
| |
2. Back up the hard disk, if possible, and run PREP |
| |
to reinitialize the disk (see 'Running PREP'.) |
| |
Reformat disk and install operating system. |
| |
3. Hard Disk Drive |
| Overflow ! |
1. Power-off computer, wait 15 seconds, |
| |
then power-on computer. If message reappears during |
| |
power up, replace system board. |
| |
2. If a software problem is suspected, try another copy |
| |
of the program, or have the customer contact the |
| |
software manufacturer or dealer and report the problem. |
| Password Security Violation: |
1. Power-off computer, wait 15 seconds, then |
| System Shutdown |
power-on the computer. |
| |
2. Retry the password. If password is unknown, clear the |
| |
password (see 'Power-on Password'). |
| Program verify failure. |
1. System Board |
| Remove diskette and insert again, |
1. Try another Advanced Diagnostics diskette. |
| otherwise reboot. |
2. System Board |
| Retries exhausted, please remove diskette. |
1. Try another Advanced Diagnostics diskette. |
| |
2. System Board |
| Slush BIOS Checksum Error ! |
1. System Board |
| Slush RAM Data Error ! |
1. System Board |
| Slush Video Checksum Error ! |
1. System Board |
| Wild Interrupt ! |
1. Power-off computer, wait 15 seconds, then |
| |
power-on computer. Rerun the program. |
| |
2. If the message reoccurs at the same place during the |
| |
operation of a program, it is probably software related. |
| |
Have the customer contact the software manufacturer or |
| |
dealer to report problem. |
| |
3. If the message reoccurs randomly, run Advanced Diagnostics. |
| |
Replace any faulty assemblies. |