System management codes
The following page contains the system management codes.
These codes are displayed on the front panel.
Notes:
Table 16. System Management Codes
Code/Description
FRU/Action
00
1. See the system error log and follow the instruction for the
(POST failed)
error in the log.
2. See 'Undetermined problems'.
01
1. See the system error log and follow the instruction for the
(POST warning)
error in the log.
08
1. See the system error log and follow the instruction for the
(Application failed)
error in the log.
09
1. See the system error log and follow the instruction for the
(Application warning)
error in the log.
10
1. Try to reboot the system.
(Boot failed)
2. See system error log for other possible errors.
3. See 'Undetermined problems'.
18
1. Restart the server.
(Operating system failed)
20
1. Clean out the error log.
(Log full)
30
1. See the system error log for more information
(CPU Fail)
regarding the failure.
2. Processor indicated by the component fault indicator LED.
3. Processor daughter board
4. Cache coherency filter DIMMs (if applicable)
5. Processor controller board
70
1. See the system error log for more information
(VRM fail)
regarding the failure.
2. Replace the VRM (if possible) or circuit card
that contains the VRM.
Replaceable VRMs are located on the I/O board.
Non-replaceable VRMs are located on the processor
daughter board(s).
80
1. Ensure that all six fans are working, and that
(Over temperature)
all three power supplies are functional.
2. Ensure the air intakes are clear.
3. Ensure the room temperature is not too hot.
See 'Specifications'
4. Replace the following FRU for the temperature failure
indicated in the error log:
° Ambient temperature - replace the front panel
° Hard disk drive temperature - replace the SCSI backplane
° Processor temperature - replace the processor
85
1. See system error log to determine if there are any
(Over voltage)
power supply or VRM errors.
2. Replace the power supply, if indicated by the error log.
3. Replace the VRM (if possible) or circuit card that contains
the VRM. Replaceable VRMs are located on the I/O board.
Non-replaceable VRMs are located on the processor daughter board(s).
4. Power control card
5. Processor daughter board
6. Processor control board
86
1. See system error log to determine if there are any
(Low voltage)
power supply or VRM errors.
2. Replace the power supply, if indicated by the error log.
3. Replace the VRM (if possible) or circuit card that contains
the VRM. Replaceable VRMs are located on the I/O board.
Non-replaceable VRMs are located on the processor daughter board(s).
4. Power control card
5. Processor daughter board
6. Processor controller board
90
1. Power supply X
(Power supply X)
2. Power control card
3. System management adapter cable
4. System management adapter
98
1. See system error log to determine if there are any
(Power system)
power supply or VRM errors.
2. Replace the power supply, if indicated by the error log.
3. Replace the VRM (if possible) or circuit card that contains
the VRM. Replaceable VRMs are located on the I/O board.
Non-replaceable VRMs are located on the processor daughter board(s).
4. Power control card
99
1. Check all power supplies.
(Non-Redundant)
2. Replace faulty power supply, or add additional power
This is a warning to
supply if operating with fewer than three power supplies.
the operator.
The load on the power
subsystem is large enough
that the power subsystem
is no longer operating
with redundancy.
If one of the power
supplies were to fail,
the remaining power
supplies may not be
able to reliably power
the system.
A0
1. Fan X
(Fan X, see
2. Midplane (I/O fans)
'Other error symptoms')
3. LED card (CPU fans)
4. Power control card
B0
1. Ensure the covers are attached correctly.
(Intrusion - tower
2. Verify that there has been an intrusion into the system.
configuration only)
3. Intrusion Cable
4. Front Panel
B8
1. Check the cable connection from the I/O function
(Display)
card (VFD display) to the front panel.
2. Front Panel
C0
1. See the system error log and follow the instruction
(SMI error)
for the error in the log.
2. Replace the FRU for the following problems listed.
° PCI related error:
a. PCI Adapter
b. PCI switch card
c. I/O Board
° Processor related error:
a. Processor
b. Processor Daughter Board
c. Processor Controller Board
° Memory related error:
a. DIMM
b. Memory Board
c. Processor Daughter Board
d. Processor Controller Board
° SCSI related error
a. Check SCSI cable
b. SCSI backplane (if internal SCSI drives)
c. SCSI adapter (if external drives attached to
a PCI SCSI adapter)
d. I/O function card (if either internal or
external SCSI drives are attached to this card)
e. SCSI drive
C1
1. See system error log to determine which DIMM failed.
(Memory)
2. Run diagnostics on memory.
Device not installed
1. See the system error log for more information
(A card or cable
regarding which device is not installed.
needs to be installed)
2. Install the specified device.
Please see the LEGAL - Trademark notice.