Diagnostic error codes - (NF 8500R - Type 8681)


Diagnostic error codes

In the following error codes, X can be any number or letter.


Note 1 -Important- This is a duplicate error code used for adapters and disk drives.
To verify the type of failure, see the system error log.

Error Code/Symptom    FRU/Action
   
   001-XXX-XXX 1. I/O Function Card
   (Failed core tests) 2. I/O Board
005-XXX-XXX 1. I/O Function Card
   (Failed Video test) 2. I/O Board
011-XXX-XXX 1. I/O Function Card
   (Failed Serial Port test) 2. I/O Board
014-XXX-XXX 1. I/O Function Card
   (Failed Parallel Port test) 2. I/O Board
015-XXX-XXX 1. I/O Board
   (Failed USB test) 2. I/O Function Card
030-XXX-000 1. I/O Function Card
   (Failed Internal SCSI 2. I/O Board
   interface test -channel 0)  
030-XXX-001 1. I/O Function Card
   (Failed Internal SCSI 2. I/O Board
   interface test -channel 1)  
035-XXX-000 1. SCSI Drive Cable
   (Failed RAID test for 2. RAID Adapter 1
   adapter in slot 1) 3. SCSI Backplane
035-XXX-001 1. Fixed Disk 1
   (Failed RAID test for Fixed 2. SCSI Drive Cable
   Disk in bay 1 SCSI ID 0) 3. RAID Adapter
   Note 1 4. SCSI Backplane
035-XXX-001 1. SCSI Drive Cable
   (Failed RAID test for 2. RAID Adapter 2
   adapter in slot 2) 3. SCSI Backplane
   Note 1  
035-XXX-002 1. Fixed Disk 2
   (Failed RAID test for Fixed 2. SCSI Drive Cable
   Disk in bay 2 SCSI ID 1) 3. RAID Adapter
   Note 1 4. SCSI Backplane
035-XXX-002 1. SCSI Drive Cable
   (Failed RAID test for 2. RAID Adapter 3
   adapter in slot 3) 3. SCSI Backplane
   Note 1  
035-XXX-003 1. SCSI Drive Cable
   (Failed RAID test for 2. RAID Adapter 4
   adapter in slot 4) 3. SCSI Backplane
035-XXX-004 1. SCSI Drive Cable
   (Failed RAID test for 2. RAID Adapter 5
   adapter in slot 5) 3. SCSI Backplane
035-XXX-005 1. SCSI Drive Cable
   (Failed RAID test for 2. RAID Adapter 6
   adapter in slot 6) 3. SCSI Backplane
035-XXX-006 1. SCSI Drive Cable
   (Failed RAID test for 2. RAID Adapter 7
   adapter in slot 7) 3. SCSI Backplane
035-XXX-007 1. SCSI Drive Cable
   (Failed RAID test for 2. RAID Adapter 8
   adapter in slot 8) 3. SCSI Backplane
035-XXX-008 1. SCSI Drive Cable
   (Failed RAID test for 2. RAID Adapter 9
   adapter in slot 9) 3. SCSI Backplane
035-XXX-009 1. SCSI Drive Cable
   (Failed RAID test for 2. RAID Adapter 10
   adapter in slot 10) 3. SCSI Backplane
035-XXX-010 1. SCSI Drive Cable
   (Failed RAID test for 2. RAID Adapter 11
   adapter in slot 11) 3. SCSI Backplane
035-XXX-011 1. SCSI Drive Cable
   (Failed RAID test for 2. RAID Adapter 12
   adapter in slot 12) 3. SCSI Backplane
035-XXX-099 1. If an adapter is installed, re-check its connection
   (No adapters found)  
035-XXX-Y99 1. RAID Adapter in slot Y
   (Failed RAID test on PCI 2. SCSI Backplane
   slot Y. Check system error 3. Cable
   log before replacing a FRU.)  
035-253-Y99 1. ServeRAID adapter in slot Y is not configured properly.
   (RAID adapter initialization     Obtain the basic and extended configuration status and
   failure)     refer to the ServeRAID HMM for more information.
035-XXX-YNN 1. Fixed disk with SCSI ID NN on RAID adapter in PCI slot Y
   (Fixed disk error at SCSI ID  
   NN on slot Y. Check system  
   error log before replacing a  
   FRU.)  
089-XXX-001 1. Cache Coherency DIMMs, if two Processor Daughter Boards
   (Failed Microprocessor test)     are installed.
      Disregard if a single Processor Daughter Board is installed.
  2. Processor B1
  3. Processor Daughter Board B
  4. Processor Controller Board
089-XXX-002 1. Cache Coherency DIMMs, if two Processor Daughter Boards
   (Failed Microprocessor test)     are installed.
      Disregard if a single Processor Daughter Board is installed.
  2. Processor B2
  3. Processor Daughter Board B
  4. Processor Controller Card
089-XXX-003 1. Cache Coherency DIMMs, if two Processor Daughter Boards
   (Failed Microprocessor test)     are installed.
      Disregard if a single Processor Daughter Board is installed.
  2. Processor B3
  3. Processor Daughter Board B
  4. Processor Controller Card
089-XXX-004 1. Cache Coherency DIMMs, if two Processor Daughter Boards
   (Failed Microprocessor test)     are installed.
      Disregard if a single Processor Daughter Board is installed.
  2. Processor B4
  3. Processor Daughter Board B
  4. Processor Controller Card
089-XXX-005 1. Cache Coherency DIMMs, if two Processor Daughter Boards
   (Failed Microprocessor test)     are installed.
      Disregard if a single Processor Daughter Board is installed.
  2. Processor A1
  3. Processor Daughter Board A
  4. Processor Controller Card
089-XXX-006 1. Cache Coherency DIMMs, if two Processor Daughter Boards
   (Failed Microprocessor test)     are installed.
      Disregard if a single Processor Daughter Board is installed.
  2. Processor A2
  3. Processor Daughter Board A
  4. Processor Controller Card
089-XXX-007 1. Cache Coherency DIMMs, if two Processor Daughter Boards
   (Failed Microprocessor test)     are installed.
      Disregard if a single Processor Daughter Board is installed.
  2. Processor A3
  3. Processor Daughter Board A
  4. Processor Controller Card
089-XXX-008 1. Cache Coherency DIMMs, if two Processor Daughter Boards
   (Failed Microprocessor test)     are installed.
      Disregard if a single Processor Daughter Board is installed.
  2. Processor A4
  3. Processor Daughter Board A
  4. Processor Controller Card
165-XXX-000 1. System Management Adapter
   (Failed System 2. System Management Adapter Cable
   Management Adapter test) 3. Front Panel Cable
  4. Front Panel
  5. I/O Function Card
180-XXX-000 1. System Management Adapter
   (LED test failed)  
180-XXX-001 1. Front Panel Cable
   (LED test failed) 2. Front Panel
  3. System Management Adapter
180-XXX-002 1. Memory Card B
   (Memory Card B LED test failed) 2. LED Card
  3. Midplane
180-XXX-003 1. Memory Card A
   (Memory Card A LED test failed) 2. LED Card
  3. Midplane
180-XXX-004 1. I/O Board
   (PCI Power/Attention LED test failed) 2. Retention Bracket
180-XXX-005 1. PCI switch card
   (Retention bracket failure) 2. I/O Function card
  3. I/O Board
180-XXX-006 1. SCSI Drive Cable
   (ASPI not loaded) 2. SCSI Backplane
  3. I/O Function Card
180-XXX-007 1. Drive Cable
   (DASD LED failed, see 2. DASD backplane
   message for slot)  
180-XXX-008 1. LED Card
   (DIMM LEDs failed) 2. Midplane
180-XXX-009 1. LED Card
   (CPU LEDs failed) 2. Processor Daughter Board A
  3. Processor Daughter Board B
185-XXX-001 1. Intrusion Cable
   (Intrusion Security test failed) 2. Front Panel Cable
  3. Front Panel
  4. I/O Function Card
185-XXX-002 1. Intrusion Cable
   (Intrusion Security test failed) 2. Front Panel Cable
  3. Front Panel
  4. I/O Function Card
201-004-1DD 1. DIMM (See message for DIMM Number)
   (Single Bit Memory Error on 2. Memory Card B
   Memory Card B) 3. Midplane
   DD = DIMM Number (silk  
   screened on memory card)  
201-004-2DD 1. DIMM (See message for DIMM Number)
   (Single Bit Memory Error on 2. Memory Card A
   Memory Card A) 3. Midplane
   DD = DIMM Number (silk  
   screened on memory card)  
201-199-000 1. DIMM
   (General memory failure) 2. Memory Card A
  3. Memory Card B
  4. Midplane
201-204-1DD 1. DIMM (See message for DIMM Number)
   (Multiple Bit Memory Error 2. Memory Card B
   on Memory Card B) 3. Midplane
   DD = DIMM Number (silk  
   screened on memory card)  
201-204-2DD 1. DIMM (See message for DIMM Number)
   (Multiple Bit Memory Error 2. Memory Card A
   on Memory Card A) 3. Midplane
   DD = DIMM Number (silk  
   screened on memory card)  
201-XXX-001 1. DIMM (Verify failing FRU in system error log.)
   (Failed ECC test)  
202-XXX-001 1. Processor B1
   (Failed Cache test) 2. Processor Daughter Board B
  3. Processor Controller Card
202-XXX-002 1. Processor B2
   (Failed Cache test) 2. Processor Daughter Board B
  3. Processor Controller Card
202-XXX-003 1. Processor B3
   (Failed Cache test) 2. Processor Daughter Board B
  3. Processor Controller Card
202-XXX-004 1. Processor B4
   (Failed Cache test) 2. Processor Daughter Board B
  3. Processor Controller Card
202-XXX-005 1. Processor A1
   (Failed Cache test) 2. Processor Daughter Board A
  3. Processor Controller Card
202-XXX-006 1. Processor A2
   (Failed Cache test) 2. Processor Daughter Board A
  3. Processor Controller Card
202-XXX-007 1. Processor A3
   (Failed Cache test) 2. Processor Daughter Board A
  3. Processor Controller Card
202-XXX-008 1. Processor A4
   (Failed Cache test) 2. Processor Daughter Board A
  3. Processor Controller Card
206-XXX-XXX 1. Diskette Drive Cable
   (Failed Diskette Drive test) 2. Media power cable
  3. Diskette Drive
  4. I/O Function Card
215-XXX-000 1. CD-ROM Drive Cable
   (Failed CD-ROM test) 2. Media power cable
  3. CD-ROM drive
  4. I/O Function Card
217-XXX-001 1. Fixed Disk 1
   (Failed BIOS Fixed Disk test)  
217-XXX-002 1. Fixed Disk 2
   (Failed BIOS Fixed Disk test)  
301-XXX-XXX 1. Keyboard
   (Failed Keyboard test) 2. I/O Function Card
415-XXX-XXX 1. Modem Card
   (Failed modem test)  


Note 1 -Important- This is a duplicate error code used for adapters and disk drives.
To verify the type of failure, see the system error log.


Please see the LEGAL  -  Trademark notice.
Feel free - send a Email-NOTE  for any BUG on this page found - Thank you.