Diagnostic error codes
In the following error codes, X can be any number or letter.
Note 1 -Important- This is a duplicate error code used for adapters and disk drives.
To verify the type of failure, see the system error log.
Error Code/Symptom
FRU/Action
001-XXX-XXX
1. I/O Function Card
(Failed core tests)
2. I/O Board
005-XXX-XXX
1. I/O Function Card
(Failed Video test)
2. I/O Board
011-XXX-XXX
1. I/O Function Card
(Failed Serial Port test)
2. I/O Board
014-XXX-XXX
1. I/O Function Card
(Failed Parallel Port test)
2. I/O Board
015-XXX-XXX
1. I/O Board
(Failed USB test)
2. I/O Function Card
030-XXX-000
1. I/O Function Card
(Failed Internal SCSI
2. I/O Board
interface test -channel 0)
030-XXX-001
1. I/O Function Card
(Failed Internal SCSI
2. I/O Board
interface test -channel 1)
035-XXX-000
1. SCSI Drive Cable
(Failed RAID test for
2. RAID Adapter 1
adapter in slot 1)
3. SCSI Backplane
035-XXX-001
1. Fixed Disk 1
(Failed RAID test for Fixed
2. SCSI Drive Cable
Disk in bay 1 SCSI ID 0)
3. RAID Adapter
Note 1
4. SCSI Backplane
035-XXX-001
1. SCSI Drive Cable
(Failed RAID test for
2. RAID Adapter 2
adapter in slot 2)
3. SCSI Backplane
Note 1
035-XXX-002
1. Fixed Disk 2
(Failed RAID test for Fixed
2. SCSI Drive Cable
Disk in bay 2 SCSI ID 1)
3. RAID Adapter
Note 1
4. SCSI Backplane
035-XXX-002
1. SCSI Drive Cable
(Failed RAID test for
2. RAID Adapter 3
adapter in slot 3)
3. SCSI Backplane
Note 1
035-XXX-003
1. SCSI Drive Cable
(Failed RAID test for
2. RAID Adapter 4
adapter in slot 4)
3. SCSI Backplane
035-XXX-004
1. SCSI Drive Cable
(Failed RAID test for
2. RAID Adapter 5
adapter in slot 5)
3. SCSI Backplane
035-XXX-005
1. SCSI Drive Cable
(Failed RAID test for
2. RAID Adapter 6
adapter in slot 6)
3. SCSI Backplane
035-XXX-006
1. SCSI Drive Cable
(Failed RAID test for
2. RAID Adapter 7
adapter in slot 7)
3. SCSI Backplane
035-XXX-007
1. SCSI Drive Cable
(Failed RAID test for
2. RAID Adapter 8
adapter in slot 8)
3. SCSI Backplane
035-XXX-008
1. SCSI Drive Cable
(Failed RAID test for
2. RAID Adapter 9
adapter in slot 9)
3. SCSI Backplane
035-XXX-009
1. SCSI Drive Cable
(Failed RAID test for
2. RAID Adapter 10
adapter in slot 10)
3. SCSI Backplane
035-XXX-010
1. SCSI Drive Cable
(Failed RAID test for
2. RAID Adapter 11
adapter in slot 11)
3. SCSI Backplane
035-XXX-011
1. SCSI Drive Cable
(Failed RAID test for
2. RAID Adapter 12
adapter in slot 12)
3. SCSI Backplane
035-XXX-099
1. If an adapter is installed, re-check its connection
(No adapters found)
035-XXX-Y99
1. RAID Adapter in slot Y
(Failed RAID test on PCI
2. SCSI Backplane
slot Y. Check system error
3. Cable
log before replacing a FRU.)
035-253-Y99
1. ServeRAID adapter in slot Y is not configured properly.
(RAID adapter initialization
Obtain the basic and extended configuration status and
failure)
refer to the ServeRAID HMM for more information.
035-XXX-YNN
1. Fixed disk with SCSI ID NN on RAID adapter in PCI slot Y
(Fixed disk error at SCSI ID
NN on slot Y. Check system
error log before replacing a
FRU.)
089-XXX-001
1. Cache Coherency DIMMs, if two Processor Daughter Boards
(Failed Microprocessor test)
are installed.
Disregard if a single Processor Daughter Board is installed.
2. Processor B1
3. Processor Daughter Board B
4. Processor Controller Board
089-XXX-002
1. Cache Coherency DIMMs, if two Processor Daughter Boards
(Failed Microprocessor test)
are installed.
Disregard if a single Processor Daughter Board is installed.
2. Processor B2
3. Processor Daughter Board B
4. Processor Controller Card
089-XXX-003
1. Cache Coherency DIMMs, if two Processor Daughter Boards
(Failed Microprocessor test)
are installed.
Disregard if a single Processor Daughter Board is installed.
2. Processor B3
3. Processor Daughter Board B
4. Processor Controller Card
089-XXX-004
1. Cache Coherency DIMMs, if two Processor Daughter Boards
(Failed Microprocessor test)
are installed.
Disregard if a single Processor Daughter Board is installed.
2. Processor B4
3. Processor Daughter Board B
4. Processor Controller Card
089-XXX-005
1. Cache Coherency DIMMs, if two Processor Daughter Boards
(Failed Microprocessor test)
are installed.
Disregard if a single Processor Daughter Board is installed.
2. Processor A1
3. Processor Daughter Board A
4. Processor Controller Card
089-XXX-006
1. Cache Coherency DIMMs, if two Processor Daughter Boards
(Failed Microprocessor test)
are installed.
Disregard if a single Processor Daughter Board is installed.
2. Processor A2
3. Processor Daughter Board A
4. Processor Controller Card
089-XXX-007
1. Cache Coherency DIMMs, if two Processor Daughter Boards
(Failed Microprocessor test)
are installed.
Disregard if a single Processor Daughter Board is installed.
2. Processor A3
3. Processor Daughter Board A
4. Processor Controller Card
089-XXX-008
1. Cache Coherency DIMMs, if two Processor Daughter Boards
(Failed Microprocessor test)
are installed.
Disregard if a single Processor Daughter Board is installed.
2. Processor A4
3. Processor Daughter Board A
4. Processor Controller Card
165-XXX-000
1. System Management Adapter
(Failed System
2. System Management Adapter Cable
Management Adapter test)
3. Front Panel Cable
4. Front Panel
5. I/O Function Card
180-XXX-000
1. System Management Adapter
(LED test failed)
180-XXX-001
1. Front Panel Cable
(LED test failed)
2. Front Panel
3. System Management Adapter
180-XXX-002
1. Memory Card B
(Memory Card B LED test failed)
2. LED Card
3. Midplane
180-XXX-003
1. Memory Card A
(Memory Card A LED test failed)
2. LED Card
3. Midplane
180-XXX-004
1. I/O Board
(PCI Power/Attention LED test failed)
2. Retention Bracket
180-XXX-005
1. PCI switch card
(Retention bracket failure)
2. I/O Function card
3. I/O Board
180-XXX-006
1. SCSI Drive Cable
(ASPI not loaded)
2. SCSI Backplane
3. I/O Function Card
180-XXX-007
1. Drive Cable
(DASD LED failed, see
2. DASD backplane
message for slot)
180-XXX-008
1. LED Card
(DIMM LEDs failed)
2. Midplane
180-XXX-009
1. LED Card
(CPU LEDs failed)
2. Processor Daughter Board A
3. Processor Daughter Board B
185-XXX-001
1. Intrusion Cable
(Intrusion Security test failed)
2. Front Panel Cable
3. Front Panel
4. I/O Function Card
185-XXX-002
1. Intrusion Cable
(Intrusion Security test failed)
2. Front Panel Cable
3. Front Panel
4. I/O Function Card
201-004-1DD
1. DIMM (See message for DIMM Number)
(Single Bit Memory Error on
2. Memory Card B
Memory Card B)
3. Midplane
DD = DIMM Number (silk
screened on memory card)
201-004-2DD
1. DIMM (See message for DIMM Number)
(Single Bit Memory Error on
2. Memory Card A
Memory Card A)
3. Midplane
DD = DIMM Number (silk
screened on memory card)
201-199-000
1. DIMM
(General memory failure)
2. Memory Card A
3. Memory Card B
4. Midplane
201-204-1DD
1. DIMM (See message for DIMM Number)
(Multiple Bit Memory Error
2. Memory Card B
on Memory Card B)
3. Midplane
DD = DIMM Number (silk
screened on memory card)
201-204-2DD
1. DIMM (See message for DIMM Number)
(Multiple Bit Memory Error
2. Memory Card A
on Memory Card A)
3. Midplane
DD = DIMM Number (silk
screened on memory card)
201-XXX-001
1. DIMM (Verify failing FRU in system error log.)
(Failed ECC test)
202-XXX-001
1. Processor B1
(Failed Cache test)
2. Processor Daughter Board B
3. Processor Controller Card
202-XXX-002
1. Processor B2
(Failed Cache test)
2. Processor Daughter Board B
3. Processor Controller Card
202-XXX-003
1. Processor B3
(Failed Cache test)
2. Processor Daughter Board B
3. Processor Controller Card
202-XXX-004
1. Processor B4
(Failed Cache test)
2. Processor Daughter Board B
3. Processor Controller Card
202-XXX-005
1. Processor A1
(Failed Cache test)
2. Processor Daughter Board A
3. Processor Controller Card
202-XXX-006
1. Processor A2
(Failed Cache test)
2. Processor Daughter Board A
3. Processor Controller Card
202-XXX-007
1. Processor A3
(Failed Cache test)
2. Processor Daughter Board A
3. Processor Controller Card
202-XXX-008
1. Processor A4
(Failed Cache test)
2. Processor Daughter Board A
3. Processor Controller Card
206-XXX-XXX
1. Diskette Drive Cable
(Failed Diskette Drive test)
2. Media power cable
3. Diskette Drive
4. I/O Function Card
215-XXX-000
1. CD-ROM Drive Cable
(Failed CD-ROM test)
2. Media power cable
3. CD-ROM drive
4. I/O Function Card
217-XXX-001
1. Fixed Disk 1
(Failed BIOS Fixed Disk test)
217-XXX-002
1. Fixed Disk 2
(Failed BIOS Fixed Disk test)
301-XXX-XXX
1. Keyboard
(Failed Keyboard test)
2. I/O Function Card
415-XXX-XXX
1. Modem Card
(Failed modem test)
Note 1 -Important- This is a duplicate error code used for adapters and disk drives.
To verify the type of failure, see the system error log.
Please see the LEGAL - Trademark notice.
Feel free - send a for any BUG on this page found - Thank you.