POST Error Codes - Netfinity 5600 - Type 8664


  POST Error Codes


In the following error codes, X can be any number or letter.

Error Code/Symptom    FRU/Action
062 1. Run Configuration/Setup
   (Three consecutive boot 2. Battery/CMOS Chip
   failures using the default 3. System Board
   configuration.)  
101, 102 1. System Board
   (System and processor 2. Processor Board
   error)  
106 1. System Board
   (System and processor 2. Processor Board
   error)  
111 1. Failing ISA Adapter
   (Channel check error) 2. Memory DIMM
  3. System Board
114 1. Failing Adapter
   (Adapter read-only memory 2. Run Diagnostics
   error)  
129 1. Processor
   (Internal Cache error) 2. Optional Processor (if installed)
  3. Processor Board
151 1. Run Diagnostics
   (Real time clock error) 2. Battery/CMOS chip
  3. System Board
161 1. Run Configuration/Setup
   (Real time clock battery 2. Battery/CMOS chip
   error) 3. System Board
162 1. Run Configuration/Setup
   (Device Configuration Error) 2. Battery/CMOS Chip
   - Important - 3. Failing Device
   Be sure to load the 4. System Board
   default settings and  
   any additional desired  
   settings, then, save  
   the configuration.  
163 1. Run Configuration/Setup
   (Real-Time Clock error) 2. Battery/CMOS Chip
  3. System Board
164 1. Run Configuration/Setup
   (Memory configuration 2. DIMM
   changed) 3. Processor Board
173 1. Run Configuration/Setup
   (System CMOS checksum 2. Battery/CMOS Chip
   bad) 3. System Board
175 1. System Board
   (Hardware error) 2. Processor Board
176 1. Run Configuration/Setup
   (Computer cover or cable 2. System Board
   cover was removed without  
   a key being used)  
177, 178 1. Run Configuration/Setup
   (Security hardware error) 2. Service Processor Adapter
  3. System Board
184 1. Run Configuration/Setup
   (Power-on password 2. System Board
   corrupted)  
185 1. Run Configuration/Setup
   (Drive startup sequence 2. System Board
   information corrupted)  
186 1. Run Configuration/Setup
   (Security hardware control 2. System Board
   logic failed)  
187 1. Set serial number in Setup
   (VPD serial number not set.) 2. System Board
188 1. Run Configuration/Setup
   (Bad EEPROM CRC #2) 2. System Board
189 1. Run Configuration/Setup, enter the administrator password
   (An attempt was made to  
   access the server with  
   invalid passwords)  
195 1. VRM 1
   (Processor 1 is not 2. Processor 1
   functioning) 3. Processor Board
  4. System Board
196 1. VRM 2
   (Processor 2 is not 2. Processor 2
   functioning) 3. Processor Board
  4. System Board
197 1. Processor 1
   (Processor 1 failed BIST) 2. Processor Board
  3. System Board
198 1. Processor 2
   (Processor 2 failed BIST) 2. Processor Board
  3. System Board
201 1. DIMM
   (Memory test error) 2. Processor Board
  3. System Board
229 1. Processor
   (Cache error) 2. Optional Processor (if installed)
  3. Processor Board
262 1. Run Configuration/Setup
   (DRAM parity configuration 2. Battery/CMOS Chip
   error) 3. System Board
289    1. Run Configuration/Setup, if disabled by user
   (DIMM has been disabled 2. Ensure if a DIMM was added/changed that
   by the user or system)     the power was disconnected.
  3. Disabled DIMM, if not disabled by user.
  4. Processor board
301 1. Keyboard
   (Keyboard or keyboard 2. System Board
   controller error)  
303 1. Keyboard
   (Keyboard controller error) 2. System Board
602 1. Diskette
   (Invalid diskette boot record) 2. Cable
  3. Diskette Drive
604 1. Run Configuration/Setup and Diagnostics
   (Diskette drive error) 2. Diskette Drive
  3. Drive Cable
  4. System Board
605 1. Diskette Drive
   (Unlock failure) 2. Drive Cable
  3. System Board
662 1. Run Configuration/Setup and Diagnostics
   (Diskette drive configuration 2. Diskette Drive
   error) 3. Drive Cable
  4. System Board
762 1. Run Configuration/Setup
   (Coprocessor configuration 2. Battery/CMOS Chip
   error) 3. Processor
962 1. Disconnect external cable on parallel port.
   (Parallel port error) 2. Run Configuration/Setup
  3. System Board
11XX 1. Disconnect external cable on serial port.
   (System-board serial port 1 2. Run Configuration/Setup
   or 2 error) 3. System Board
1301 1. Cable
   (I2C cable to front panel 2. Front Panel
   not found) 3. Power Switch Assembly
  4. System Board
1302 1. Cable
   (I2C cable from system board 2. Power Switch Assembly
   to power on and reset switches 3. System Board
   not found)  
1303 1. Cable
   (I2C cable from system board 2. Power Backplane
   to power backplane not found) 3. System Board
1304 1. Cable
   (Cable to diagnostic LED  
   panel not detected)  
1600, 1601 1. System Board
   (The system is able to 2. Processor Board
   communicate to the Service  
   Processor, but the Service  
   Processor failed to respond  
   at the start of POST.)  
   Do the following before  
   replacing a FRU:  
   1. Remove the AC power to  
   to the system, wait 20  
   seconds, then,  
   re-connect the AC power  
   Wait 30 seconds, then  
   power-on the system.  
   2. Flash update the  
   Service Processor.  
   3. Check the SP reset jumper  
   if fitted.  
1762 1. Fixed Disk Cables
   (Fixed Disk Configuration 2. Run Configuration/Setup
   error) 3. Fixed Disk Adapter, if fitted
  4. Fixed Disk Drive
  5. System Board
178X 1. Fixed Disk Cables
   (Fixed Disk error) 2. Run Diagnostics
  3. Fixed Disk Adapter
  4. Fixed Disk Drive
  5. System Board
1800 1. Run Configuration/Setup
   (No more hardware interrupt 2. Failing Adapter
   available for PCI adapter) 3. System Board
1801 1. Run Configuration/Setup
   (No room for PCI option 2. Failing Adapter
   ROM) 3. System Board
1802 1. Run Configuration/Setup
   (No more I/O space 2. Failing Adapter
   available for PCI adapter) 3. System Board
1803 1. Run Configuration/Setup
   (No more memory (above 2. Failing Adapter
   1MB for PCI adapter) 3. System Board
1804 1. Run Configuration/Setup
   (No more memory (below 2. Move the failing adapter to slot 1 or 2
   1MB for PCI adapter) 3. Failing Adapter
  4. System Board
1805 1. Remove Failing PCI Card
   (PCI option ROM checksum 2. System Board
   error)  
1806 1. Run Configuration/Setup
   (PCI to PCI Bridge error) 2. Move the failing adapter to slot 1 or 2
  3. Failing Adapter
  4. System Board
1807, 1808, 1810 1. Remove Failing PCI Card
   (General PCI error) 2. System Board
1962 1. Verify a bootable operating system is installed
   (Drive does not contain a 2. Run Diagnostics
   valid boot sector) 3. Hard Disk Drive
  4. SCSI Backplane
  5. Cable
  6. System Board
2400 1. Video Adapter (if installed)
   (Video controller test failure) 2. System Board
2462 1. Video Adapter (if installed)
   (Video memory 2. System Board
   configuration error)  
5962 1. Run Configuration/Setup
   (IDE CD-ROM configuration 2. CD-ROM Drive
   error) 3. CD-ROM Power Cable
  4. IDE Cable
  5. System board
  6. Battery
8603 1. Pointing Device
   (Pointing Device Error) 2. System Board
0001200 1. Processor
   (Machine check architecture 2. Optional Processor
   error)  
000120P0,  
   000120P1, 000120P2, 000120PF 1. Failing Processor
   (Processor cache error) 2. Processor Board
01295085 1. Processor
   (ECC checking hardware 2. Processor Board
   test error)  
I9990301 1. Run Configuration/Setup for correct startup
   (Fixed boot sector error, 2. Verify operating system installed
   no operating system installed)  
I9990305 1. Install operating system to hard disk drive.
   (Fixed boot sector error, no  
   operating system installed)  
I9990650 1. Check Cable
   (AC power has been 2. Check for interruption of power supply
   restored) 3. Power Cable


Please see the LEGAL  -  Trademark notice.
Feel free - send a Email-NOTE  for any BUG on this page found - Thank you.