Diagnostic Error Codes
-Attention-
In the following error codes, if XXX is 000, 195 , or 197 do not replace a FRU.
The description for these error codes are:
000
The test passed.
195
The Esc key was pressed to abort the test.
197
This a warning error and may not indicate a hardware failure.
For all other error codes, replace/follow the FRU/Action indicated.
Error Code/Symptom
FRU/Action
001-XXX-000
1. System Board
(Failed core tests)
001-250-001
1. Processor Board
(Failed ECC test)
2. System Board
005-XXX-000
1. System Board
(Failed Video test)
2. Processor Board
011-XXX-000
1. System Board
(Failed COM1 Serial Port test)
011-XXX-001
1. System Board
(Failed COM2 Serial Port test)
014-XXX-000
1. System Board
(Failed Parallel Port test)
015-XXX-001
1. System Board
(Failed USB test)
020-XXX-000
1. System Board
(Failed PCI Interface test)
2. Processor Board
030-XXX-000
1. System Board
(Failed internal SCSI
interface test)
030-XXX-00N
1. Adapter on PCI slot N
(Failed SCSI test on PCI
slot N. Check system error
log before replacing a FRU.)
035-XXX-099
1. If adapter is installed, recheck connections
(No adapters were found)
035-XXX-199
1. Adapter
(Failed RAID test on PCI
2. SCSI Backplane
slot 1. Check system error
3. Cable
log before replacing a FRU.)
035-253-199
1. ServeRAID Adapter in PCI slot 1
(RAID adapter initialization
is not configured properly.
failure)
Obtain the basic and extended configuration
status and refer to the ServeRAID HMM for
more information.
035-XXX-1NN
1. Fixed disk with SCSI ID NN on RAID adapter in PCI slot 1
(Check system error log
before replacing a FRU.
NN = SCSI ID or fixed disk.)
035-XXX-299
1. Adapter
(Failed RAID test on PCI
2. SCSI Backplane
slot 2. Check system error
3. Cable
log before replacing a FRU.)
035-253-299
1. ServeRAID Adapter in PCI slot 2 is not
(RAID adapter initialization
configured properly.
failure)
Obtain the basic and extended configuration status
and refer to the ServeRAID HMM for more information.
035-XXX-2NN
1. Fixed disk with SCSI ID NN on RAID adapter in PCI slot 2
(Check system error log
before replacing a FRU.
NN = SCSI ID or fixed disk.)
035-XXX-399
1. Adapter
(Failed RAID test on PCI
2. SCSI Backplane
slot 3. Check system error
3. Cable
log before replacing a FRU.)
035-253-399
1. ServeRAID Adapter in PCI slot 3 is not configured properly.
(RAID adapter initialization
Obtain the basic and extended configuration status and refer to the
failure)
ServeRAID HMM for more information.
035-XXX-3NN
1. Fixed disk with SCSI ID NN on RAID adapter in PCI slot 3
(Check system error log
before replacing a FRU.
NN = SCSI ID or fixed disk.)
035-XXX-499
1. Adapter
(Failed RAID test on PCI
2. SCSI Backplane
slot 4. Check system error
3. Cable
log before replacing a FRU.)
035-253-499
1. ServeRAID Adapter in PCI slot 4 is not configured properly.
(RAID adapter initialization
Obtain the basic and extended configuration status and refer to the
failure)
ServeRAID HMM for more information.
035-XXX-4NN
1. Fixed disk with SCSI ID NN on RAID adapter 4 in PCI slot 4.
(Check system error log
before replacing a FRU.
NN = SCSI ID of failing FRU.)
035-XXX-599
1. Adapter
(Failed RAID test on PCI
2. SCSI Backplane
slot 5. Check system error
3. Cable
log before replacing a FRU.)
035-253-599
1. ServeRAID Adapter in PCI slot 5 is not configured properly.
(RAID adapter initialization
Obtain the basic and extended configuration status and refer to the
failure)
ServeRAID HMM for more information.
035-XXX-5NN
1. Fixed disk with SCSI ID NN on RAID adapter in PCI slot 5.
(Check system error log
before replacing a FRU.
NN = SCSI ID of failing
fixed disk.)
075-XXX-000
1. Power Supply
(Failed Power Supply test)
2. Power Backplane/cable
089-XXX-001
1. Microprocessor
(Failed Microprocessor test)
2. VRM for Microprocessor
3. Processor Board
4. System Board
089-XXX-002
1. Optional Microprocessor
(Failed Optional
2. VRM for Optional Microprocessor
Microprocessor test)
3. Processor Board
4. System Board
165-XXX-000
1. System Board.
(Failed System Board test)
2. Processor Board
3. Power Backplane
4. Hot-Swap Drive Backplane
180-XXX-001
1. Information LED Panel
(Failed Information Panel
2. Power-on Panel
LED test)
180-XXX-002
1. Diagnostics LED Panel
(Failed Diagnostics LED
2. Power-on Panel
Panel test)
180-XXX-003
1. System Board
(Failed System Board LED
test)
180-XXX-004
1. Processor Board
(Failed Processor Board
2. System Board
LED test)
180-XXX-005
1. SCSI Backplane
(Failed SCSI Backplane
2. SCSI Backplane Cable
LED test)
3. System Board
201-XXX-001
1. DIMM Location J4
(Failed Memory test)
201-XXX-002
1. DIMM Location J3
(Failed Memory test)
201-XXX-003
1. DIMM Location J2
(Failed Memory test)
201-XXX-004
1. DIMM Location J1
(Failed Memory test)
201-XXX-999
1. See error text for failing DIMMs
(Multiple DIMM failure, see
error text.)
202-XXX-001
1. Microprocessor
(Failed System Cache test)
202-XXX-002
1. Optional Microprocessor
(Failed System Cache test
on Optional Microprocessor)
206-XXX-000
1. Diskette Drive cable
(Failed Diskette Drive test)
2. Diskette Drive
215-XXX-000
1. CD-ROM Drive Cables
(Failed IDE CD-ROM test)
2. CD-ROM Drive
3. System Board
217-XXX-000
1. Fixed Disk 1
(Failed BIOS Fixed Disk test)
Note:
If RAID is configured, the
fixed disk number refers
to the RAID logical drive.
217-XXX-001
1. Fixed Disk 2
(Failed BIOS Fixed Disk test)
Note:
If RAID is configured, the
fixed disk number refers
to the RAID logical drive.
217-XXX-002
1. Fixed Disk 3
(Failed BIOS Fixed Disk test)
Note:
If RAID is configured, the
fixed disk number refers
to the RAID logical drive.
217-XXX-003
1. Fixed Disk 4
(Failed BIOS Fixed Disk test)
Note:
If RAID is configured, the
fixed disk number refers
to the RAID logical drive.
217-XXX-004
1. Fixed Disk 5
(Failed BIOS Fixed Disk test)
Note:
If RAID is configured, the
fixed disk number refers
to the RAID logical drive.
217-XXX-005
1. Fixed Disk 6
(Failed BIOS Fixed Disk test)
Note:
If RAID is configured, the
fixed disk number refers
to the RAID logical drive.
264-XXX-0YY
1. Tape Cartridge, if user executed the Read/Write
(Failed Tape Drive Test)
Tape Drive test (failure code of XXX=256).
2. SCSI or power cable connected to the tape drive with SCSI ID YY.
3. Tape Drive with SCSI ID YY.
Refer to the Help and Service Information appendix of the
tape drive's User Guide.
4. System board or SCSI controller.
Run SCSI Controller Diagnostics to determine if the
SCSI bus is functioning properly.
264-XXX-999
1. See error messages/text in the PC Doctor error log
(Error on multiple tape
for detailed information on each individual tape drive error.
drives, see error text for
more information)
301-XXX-000
1. Keyboard
(Failed Keyboard test)
405-XXX-000
1. System Board
(Failed Ethernet test)
405-XXX-00X
1. Fault Tolerant Ethernet Card
(Failed Fault Tolerant
Ethernet test)
Please see the LEGAL - Trademark notice.
Feel free - send a for any BUG on this page found - Thank you.