Standard Features of the Storage Enclosures
The following table provides basic information about the PC Server 3518, the PC Server 3519, the
Netfinity EXP10, and the Netfinity EXP15 storage enclosures.
Enclosure 3518 3519 EXP10 EXP15
-------------------------------------------------------------------------------------------------
Form Factor Tower Rack Drawer Rack Drawer Rack Drawer
5U (1) 3U (1) 3U (1)
-------------------------------------------------------------------------------------------------
Subsystem Type SCSI SCSI Ultra SCSI Ultra SCSI LVDS
-------------------------------------------------------------------------------------------------
Total Bays 20 9 10 10
-------------------------------------------------------------------------------------------------
Hot-Swap Bays 18 6 10 10
-------------------------------------------------------------------------------------------------
Half-High Device Bays 2 3 0 0
-------------------------------------------------------------------------------------------------
Maximum Internal 182 GB 155 72.8 GB (2) 182 GB (2) 182 GB (2)
Storage Capacity
-------------------------------------------------------------------------------------------------
Power Supply 470 Watt 200 Watt 265 Watt Redundant 350 Watt
Redundant
-------------------------------------------------------------------------------------------------
Maximum Weight 119 lb. 60 lb. 92 lb. 92 lb.
-------------------------------------------------------------------------------------------------
(1) 1U is 44.45 mm (1.75 inches).
(2) This figure represents raw-storage capacity.
Several factors influence the actual amount of useable-storage capacity, such as the drive's capacity and the RAID levels assigned.