Quorum Modifications for the Netfinity 7000 Rack Cluster Example


Quorum Modifications for the Netfinity 7000 Rack Cluster Example

If you want to use the Microsoft Cluster Server program, you can modify this example configuration as follows:

  1.  Install two 4.5 GB drives in expansion unit 3, then, define the two drives as one RAID level-1 logical  drive that you can use as your quorum drive.
  2.  In Server B, use the ServeRAID utility program to change the ServeRAID Adapter 2 Channel 3 SCSI ID from 7 to 6.
  3.  Install a Third Channel Cable Option on Channel 3 of ServeRAID Adapter 2 in both servers.

    Note: The part number for the ServeRAID II Third Channel Cable option is 76H5400.
     If you are connecting ServeRAID-3H adapters to the Quorum drive, install the Third Channel Cable  option provided with the ServeRAID-3H adapter.

  4.  Attach an 8-mm to 68-pin converter, IBM Part Number 01K8017, to one of the ServeRAID Adapter 2  Channel 3 external connectors.
  5.  Using a 4.3 meter cable, IBM Part Number 01K8029, connect Channel 3 of ServeRAID Adapter 2 in  Server A to Channel 3 of ServeRAID Adapter 2 in Server B.