Quorum Modifications for the PC Server 325 Tower Cluster Example


Quorum Modifications for the PC Server 325 Tower Cluster Example

If you want to use the Microsoft Cluster Server program, you can modify this example configuration as follows:

  1.  In Server B, use the ServeRAID utility program to change the ServeRAID adapter Channel 3 SCSI ID  from 7 to 6.
  2.  Install a Third Channel Cable Option on the ServeRAID adapters in both servers.

    Note: The part number for the ServeRAID II Third Channel Cable option is 76H5400.
     If you are connecting ServeRAID-3H adapters to the Quorum drive, install the Third Channel Cable  option provided with the ServeRAID-3H adapter.

  3.  Attach an 8-mm to 68-pin converter, IBM Part Number 01K8017, to the external Channel 3 connector  on one of the ServeRAID adapters.
  4.  Using a 4.3 meter cable, IBM Part Number 01K8029, connect Channel 3 of the ServeRAID adapter in  Server A to Channel 3 of the ServeRAID adapter in Server B.
  5.  Install two additional hard disk drives in Banks C or D.
  6.  Define the two drives as one RAID level-1 logical drive, then, use that logical drive as your quorum drive.


Please see the LEGAL  -  Trademark notice.
Feel free - send a Email-NOTE  for any BUG on this page found - Thank you.