Viewing the test log
Errors reported by the diagnostic test will be displayed by
the program as a failed test.
To view details of a failure or to view a list of test results,
do the following from any test category screen:
Message
Failure Found
Recommended Actions
2xx-1y
A memory error was
detected in SIMM
socket YReplace the SIMM in the socket
identified by the last digit
of the error code. Re-run the
test. If the same error code
occurs again, replace the
system board.
2xx-2y
A memory error was
detected in DIMM
socket YReplace the DIMM in the socket
identified by the last digit
of the error code. Re-run the
test. If the same error code
occurs again, replace the
system board or where memory
is on the processor card,
replace the processor card.
Corrupt
BIOSInformation in BIOS
is not as expected.
Not able to find
expected DMI
information from
BIOS. Memory
controller chipset
vendor ID does not
match expected
value.Reflash the BIOS.
Replace the system board.
Test
aborted
by userUser stopped test.
Restart test.