| RAID Adapter Message |
Action |
| |
|
| n logical drives are installed |
n represents the number of defined logical |
| |
drives. |
| |
This is an information message. No action is required. |
| Controller is not responding to |
The ServeRAID adapter is not operational. |
| commands. No logical drives are |
Make sure that the adapter is fully seated. If the |
| installed. |
problem persists, have the system serviced. |
| Error : Cannot disable this |
The adapter was unable to prevent an extra copy |
| adapter BIOS. |
of the adapter BIOS from being stored on the server. |
| |
This condition occurs when the server contains multiple |
| |
ServeRAID adapters. |
| |
When the prompt to disable extra copies on the adapter |
| |
BIOS appears, type N (No) |
| Following drives not responding, |
One or more drives did not respond to the adapter. |
| (old state: new state ch: bay) |
For example, the adapterdetect a new drive in an |
| |
unconfigured bay, and the drive is not part of the |
| |
current configuration. This might also occur if the |
| |
adapter detect that a configured drive is missing. |
| |
Select F5 to accept the new state that the |
| |
ServeRAID adapter will assign to the drive. For example, |
| |
the adapter will assign the drive a state of defunct |
| |
or empty. |
| Following new drives found |
One or more drives were found in an unconfigured bay. |
| (old state: new state ch: bay) |
For each drive listed, a new state of Ready (RDY) |
| |
appears. This is an information message. No action |
| |
is required. |
| Following drives found in new |
POST found that the location of one or more drives |
| location (old ch: old bay > |
does not match the stored configuration information. |
| new ch: new bay) |
(See 'Configured Drives Are Not in the Configured Location') |
| |
for more information. |
| Installation stopped |
The server cannot access the ServeRAID adapter. |
| |
This is a follow-on message to a preceding message. |
| |
Follow the 'Action' instructions for the preceding |
| |
message to resolve the problem. |
| Recoverable configuration error, |
The configuration data stored on the adapter NVRAM does |
| run Configuration program. |
not match the configuration data stored in the adapter |
| |
EEPROM. |
| |
Insert the IBM RAID Adapter Option Diskette, then press |
| |
Ctrl+Alt+Del to restart the system. |
| |
Select Advanced Functions and synchronize the |
| |
adapter configuration. See 'Resetting the Adapter Configuration' |
| |
for more information. |
| ServeRAID firmware version xx.yy |
This is the version level of the ServeRAID adapter's firmware. |
| |
This is an information message. No action is required. |
| WARNING: n logical drives |
One or more drives have failed. |
| are critical, n logical drives |
Replace the defunct drives as soon as possible to |
| offline. |
prevent data loss. |
| The server has an error due to a |
One or more logical drives are in a blocked state. |
| Blocked Logical Drive. |
Press F4 to unblock the logical drive, or press |
| |
F5 to continue without any changes. |