SCSI LEDs - SCSI Error Codes (Netfinity 7000-M10 - Type 8680)


SCSI LEDs - SCSI Error Codes

SCSI LEDs

Check the status LED. If on, do the following:

  1.  Check the internal SCSI cable.
  2.  Replace the failing hard disk drive.
  3.  Replace the SCSI backplane.
  4.  Replace the hard disk drive controller (PCI adapter or I/O Function card).


SCSI Error Codes
Error Code    FRU/Action
All SCSI Errors 1. External SCSI devices must be powered-on before
   One or more of the following     you power-on the server.
   might be causing the problem: 2. The cables for all external SCSI devices are connected correctly.
   ° A failing SCSI device 3. If you have attached an external SCSI device to the server,
   (adapter, hard drive, controller)     make sure the external SCSI termination is set to automatic.
   ° An improper SCSI 4. The last device in each SCSI chain is terminated correctly.
   configuration or SCSI 5. The SCSI devices are configured correctly.
   termination jumper setting  
   ° Duplicate SCSI IDs in  
   the same SCSI chain  
   ° A missing or improperly  
   installed SCSI terminator  
   ° A defective SCSI terminator  
   ° An improperly installed cable  
   ° A defective cable  


Please see the LEGAL  -  Trademark notice.
Feel free - send a Email-NOTE  for any BUG on this page found - Thank you.