Diagnostic Error Codes (Netfinity 7000-M10 - Type 8680)


Diagnostic Error Codes

In the following error codes, X can be any number or letter.
Error Code/Symptom    FRU/Action
001-XXX-XXX 1. I/O Function Card
   (Failed core tests) 2. I/O Board
005-XXX-XXX 1. I/O Function Card
   (Failed Video test) 2. I/O Board
011-XXX-XXX 1. I/O Function Card
   (Failed Serial Port test) 2. I/O Board
014-XXX-XXX 1. I/O Function Card
   (Failed Parallel Port test) 2. I/O Board
015-XXX-XXX 1. I/O Board
   (Failed USB test)  
030-XXX-000 1. I/O Function Card
   (Failed Internal SCSI 2. I/O Board
   interface test -channel 0)  
030-XXX-001 1. I/O Function Card
   (Failed Internal SCSI 2. I/O Board
   interface test -channel 1)  
035-XXX-000 1. SCSI Cable
   (Failed RAID test for 2. RAID Adapter 1
   adapter in slot 1) 3. SCSI Backplane
035-XXX-001 1. Fixed Disk 1
   (Failed RAID test for Fixed 2. SCSI Cable
   Disk in bay 1 SCSI ID 0) 3. RAID Adapter
   Note 1 4. SCSI Backplane
035-XXX-001 1. SCSI Cable
   (Failed RAID test for 2. RAID Adapter 2
   adapter in slot 2) 3. SCSI Backplane
   Note 1  
035-XXX-002 1. Fixed Disk 2
   (Failed RAID test for Fixed 2. SCSI Cable
   Disk in bay 2 SCSI ID 1) 3. RAID Adapter
   Note 1 4. SCSI Backplane
035-XXX-002 1. SCSI Cable
   (Failed RAID test for 2. RAID Adapter 3
   adapter in slot 3) 3. SCSI Backplane
   Note 1  
035-XXX-003 1. Fixed Disk 3
   (Failed RAID test for Fixed 2. SCSI Cable
   Disk in bay 3, SCSI ID 2) 3. RAID Adapter
   Note 1 4. SCSI Backplane
035-XXX-003 1. SCSI Cable
   (Failed RAID test for 2. RAID Adapter 4
   adapter in slot 4) 3. SCSI Backplane
   Note 1  
035-XXX-004 1. Fixed Disk 4
   (Failed RAID test for Fixed 2. SCSI Cable
   Disk in bay 4, SCSI ID 3) 3. RAID Adapter
   Note 1 4. SCSI Backplane
035-XXX-004 1. SCSI Cable
   (Failed RAID test for 2. RAID Adapter 5
   adapter in slot 5) 3. SCSI Backplane
   Note 1  
035-XXX-005 1. SCSI Cable
   (Failed RAID test for 2. RAID Adapter 6
   adapter in slot 6) 3. SCSI Backplane
035-XXX-006 1. SCSI Cable
   (Failed RAID test for 2. RAID Adapter 7
   adapter in slot 7) 3. SCSI Backplane
035-XXX-007 1. SCSI Cable
   (Failed RAID test for 2. RAID Adapter 8
   adapter in slot 8) 3. SCSI Backplane
035-XXX-008 1. SCSI Cable
   (Failed RAID test for 2. RAID Adapter 9
   adapter in slot 9) 3. SCSI Backplane
035-XXX-009 1. SCSI Cable
   (Failed RAID test for 2. RAID Adapter 10
   adapter in slot 10) 3. SCSI Backplane
035-XXX-010 1. SCSI Cable
   (Failed RAID test for 2. RAID Adapter 11
   adapter in slot 11) 3. SCSI Backplane
035-XXX-011 1. SCSI Cable
   (Failed RAID test for 2. RAID Adapter 12
   adapter in slot 12) 3. SCSI Backplane
089-XXX-001 1. Processor 1
   (Failed Microprocessor test) 2. VRMs
  3. Processor Board
089-XXX-002 1. Processor 2
   (Failed Microprocessor test) 2. VRMs
  3. Processor Board
089-XXX-003 1. Processor 3
   (Failed Microprocessor test) 2. VRMs
  3. Processor Board
089-XXX-004 1. Processor 4
   (Failed Microprocessor test) 2. VRMs
  3. Processor Board
165-XXX-000 1. System Management Card
   (Failed System 2. System Management Card Cable
   Management Card test) 3. I/O Function Card
170-XXX-XXX 1. System Management Card
   (Voltage sensor test failed) 2. System Management Card Cable
  3. Power Control Card
175-XXX-XXX 1. System Management Card
   (Thermal sensor test failed) 2. System Management Card Cable
180-XXX-000 1. System Management Card
   (LED test failed)  
180-XXX-001 1. Front Panel
   (LED test failed) 2. System Management Card
180-XXX-002 1. Memory Card 1
   (LED test failed) 2. System Management Card
180-XXX-003 1. Memory Card 2
   (LED test failed) 2. System Management Card
180-XXX-004 1. I/O Board
   (PCI Power/Attention LED  
   tests failed)  
180-XXX-005 1. PCI Sensor Card
   (Retention bracket failure) 2. I/O Board
180-XXX-006 1. SCSI Cable
   (ASPI not loaded) 2. SCSI Backplane
  3. I/O Function Card
180-XXX-007 1. Cable
   (DASD LED failed, see 2. DASD backplane
   message for slot)  
185-XXX-001 1. Intrusion (C2 Security) Cable
   (Intrusion Security test 2. Front Panel
   failed) 3. I/O Function Card
185-XXX-002 1. Intrusion (C2 Security) Cable
   (Intrusion Security test 2. Front Panel
   failed) 3. I/O Function Card
201-XXX-000 1. Memory DIMM (see message for Card/DIMM)
   (Failed Memory Test) 2. Memory Card
  3. Processor Board
201-XXX-001 1. Memory DIMM (Verify failing FRU in system error log.)
   (Failed ECC test)  
202-XXX-000 1. BSP Processor
   (Failed System Cache test) 2. Processor Board
206-XXX-XXX 1. Diskette Drive cable
   (Failed Diskette Drive test) 2. Diskette Drive
  3. I/O Function Card
215-XXX-000 1. CD-ROM cable
   (Failed CD-ROM test) 2. CD-ROM drive
  3. I/O Board
217-XXX-001 1. Fixed Disk 1
   (Failed BIOS Fixed Disk  
   test)  
217-XXX-002 1. Fixed Disk 2
   (Failed BIOS Fixed Disk  
   test)  
217-XXX-003 1. Fixed Disk 3
   (Failed BIOS Fixed Disk  
   test)  
217-XXX-004 1. Fixed Disk 4
   (Failed BIOS Fixed Disk  
   test)  
301-XXX-XXX 1. Keyboard
   (Failed Keyboard test) 2. I/O Function Card
415-XXX-XXX 1. Modem Card
   (Failed modem test)  


Note 1 - IMPORTANT - This is a duplicate error code used for adapters and disk drives.
To verify the type of failure, see the system error log.


Please see the LEGAL  -  Trademark notice.